ACD/Labs Software Impurity Resolution Management. Presented by Peter Russell

Size: px
Start display at page:

Download "ACD/Labs Software Impurity Resolution Management. Presented by Peter Russell"

Transcription

1 ACD/Labs Software Impurity Resolution Management Presented by Peter Russell

2 Impurity Resolution Process Chemists Method Development Specialists Toxicology Groups Stability Groups Analytical Chemists 7/8/2016 Advanced Chemistry Development, Inc. (ACD/Labs) 2

3 Information is not joined-up Excel ELN LIMS Documents Lab notebooks Brain of scientists Descriptive data Discrete values Documents Structures Reaction schema Chromatography Spectroscopy

4 One-and-Done Human Interpreted Analytical Data

5 Impurity Resolution Management System Process Chemists Method Development Specialists Toxicology Groups Stability Groups Analytical Chemists 7/8/2016 Advanced Chemistry Development, Inc. (ACD/Labs) 5

6 Chromatography Process Chemists Method Development Specialists Toxicology Groups Stability Groups Analytical Chemists 7/8/2016 Advanced Chemistry Development, Inc. (ACD/Labs) 6

7 Chromatography Method Development Challenge 1: Optimal Resolution 7/8/2016 Advanced Chemistry Development, Inc. (ACD/Labs) 7

8 Chromatography Method Development Challenge 1: Optimal Resolution 7/8/2016 Advanced Chemistry Development, Inc. (ACD/Labs) 8

9 Chromatography Method Development Challenge 2: Peak Matching C_12 C_13 C_16 C_1 C_15 C_3 C_4 C_11 C_19 C_5 C_6 C_9 C_14 C_2 C_18 C_8 C_ C_11 C_10 C_5 C_8 C_17 C_19 C_9 C_7 C_13 C_25 C_2 C_3 C_21 C_6 C_12 C_18 C_23 C_1 C_14 C_15 C_20 C_ /8/2016 Advanced Chemistry Development, Inc. (ACD/Labs) 9

10 Experiment Chromatography Method Development Challenge 3: Data handling and Reporting Subsample Injection Detector 7/8/2016 Advanced Chemistry Development, Inc. (ACD/Labs) 10

11 Select Strategy & Start Point Acquire Data Select Next Experiment Automatically Track Peaks between Injections Model separations, create resolution map Separation Acceptable? Robustness Create Peak Table Final Method 7/8/2016 Advanced Chemistry Development, Inc. (ACD/Labs) 11

12 Quality by Design

13 pka7.2 N NH2 N O CH 3 H 3 C O N NH 2 H 3 C O N NH 2

14 ACD/Labs Method Development Quality by Design of Experiments Automated Peak Matching. LC-MS-UV or LC-UV Robustness Automated Reporting All data stored in a searchable database

15 Impurity Method Development ROI Moderate improvements can generate significant returns. The Road to Positive Returns, McKinsey & Company 80% reduction in development time 95% reduction in cost Extensive improvements in quality of methods

16 Impurity Method Development ROI Moderate improvements can generate significant returns. The Road to Positive Returns, McKinsey & Company A paperless flow of information from raw data A high-throughput data analysis Reduction of cycle time from more than one week to less than one day

17 Analysts and Toxicologist Process Chemists Method Development Specialists Toxicology Groups Stability Groups Analytical Chemists 7/8/2016 Advanced Chemistry Development, Inc. (ACD/Labs) 17

18 Characterizing Impurities by Spectroscopy Toxicity data can be entered against the compound 7/8/2016 Advanced Chemistry Development, Inc. (ACD/Labs) 18

19 Spectral Similarity Searching 7/8/2016 Advanced Chemistry Development, Inc. (ACD/Labs) 19

20 Mixture Searching - NMR Search for components of a mixture from within databases Label components in table 7/8/2016 Advanced Chemistry Development, Inc. (ACD/Labs) 20

21 Process Chemists and Toxicology Process Chemists Method Development Specialists Toxicology Groups Stability Groups Analytical Chemists 7/8/2016 Advanced Chemistry Development, Inc. (ACD/Labs) 21

22 Process Chemist View Synthetic Route Chromatography

23 Chromatography View Mass Chromatogram UV Chromatogram Selected component

24 Analytical Chemistry View Component Spectroscopy Toxicity data

25 Benefits Improved impurity tracking and understanding from structural data Improved search ability of analytical reference data (NMR, MS, chromatographic data) Only need to elucidate an impurity once Improved knowledge management and transfer across users and groups Faster reporting A fully searchable repository of impurity and degradant knowledge Legacy knowledge to solve future problems Quick and easy access to knowledge for prompt responses to regulatory filing agencies

Handling Human Interpreted Analytical Data. Workflows for Pharmaceutical R&D. Presented by Peter Russell

Handling Human Interpreted Analytical Data. Workflows for Pharmaceutical R&D. Presented by Peter Russell Handling Human Interpreted Analytical Data Workflows for Pharmaceutical R&D Presented by Peter Russell 2011 Survey 88% of R&D organizations lack adequate systems to automatically collect data for reporting,

More information

Introduction CONTENTS

Introduction CONTENTS Managing Impurity Knowledge in a Process Chemistry Environment Ryan Sasaki and Graham A. McGibbon Advanced Chemistry Development, Inc. Toronto, ON, Canada www.acdlabs.com CONTENTS Introduction 1 Managing

More information

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW Paula Hong, John Van Antwerp, and Patricia McConville Waters Corporation, Milford, MA, USA Historically UV detection has been

More information

Application Note 12: Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova

Application Note 12: Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova Application Note : Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova Paul Bowyer, Magritek, Inc. and Mark Dixon, Mestrelab Sample screening to verify the identity or integrity

More information

Analytical data, the web, and standards for unified laboratory informatics databases

Analytical data, the web, and standards for unified laboratory informatics databases Analytical data, the web, and standards for unified laboratory informatics databases Presented By Patrick D. Wheeler & Graham A. McGibbon ACS San Diego 16 March, 2016 Sources Process, Analyze Interfaces,

More information

Multi-residue analysis of pesticides by GC-HRMS

Multi-residue analysis of pesticides by GC-HRMS An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict

More information

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note LC walk-up system using the Agilent 12 Series LC Method Development Solution and Agilent Easy Access software Test of reaction kinetics, column scouting, and impurity checks with one LC system and up to

More information

Highly automated protein formulation development: a case study

Highly automated protein formulation development: a case study Application Note Highly automated protein formulation development: a case study Introduction and background Therapeutic proteins can be inherently prone to degradation and instability, and they often pose

More information

Optimized Flash Chromatography Purification: From TLC to large scale in three steps

Optimized Flash Chromatography Purification: From TLC to large scale in three steps Optimized Flash Chromatography Purification: From TLC to large scale in three steps Veronica Thomason Teledyne Isco, Inc. P.O. Box 82531 Lincoln, NE 68501 2 Abstract Method development, necessary for optimizing

More information

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems Technical Overview Introduction All Ions MS/MS is a technique that is available for Agilent high resolution

More information

Varian Galaxie Chromatography Data System for Preparative HPLC

Varian Galaxie Chromatography Data System for Preparative HPLC Varian Galaxie Chromatography Data System for Preparative HPLC By Gary Burce Varian, Inc. 2700 Mitchell Drive, Walnut Creek, CA 95498 USA Abstract Galaxie is an ideal chromatography data system for the

More information

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Marian Twohig, Michael D. Jones, Dominic Moore, Peter Lee, and Robert Plumb Waters Corporation, Milford, MA, USA APPLICATION

More information

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis Thermo Scientific Pesticide Explorer Collection Start-to-finish workflows for pesticide analysis Comprehensive Pesticide Analysis Solutions Pesticide Explorer Collection Selection table Lab Profile Routine

More information

ACD/AutoChrom Assisted Method Development for Challenging Separations. Vera Leshchinskaya February 7, 2018

ACD/AutoChrom Assisted Method Development for Challenging Separations. Vera Leshchinskaya February 7, 2018 ACD/AutoChrom Assisted Method Development for Challenging Separations Vera Leshchinskaya February 7, 2018 Introduction Resolution of isomeric species is one of the most challenging areas of separation

More information

MassHunter Software Overview

MassHunter Software Overview MassHunter Software Overview 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks A

More information

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs Application Note Author Harry Prest, Ph.D. Senior Chemist in GC-MS Agilent Technologies, Inc. 5301 Stevens Creek Blvd Santa Clara,

More information

Analyte Targeting for NPS Identification in Seized Drugs and Toxicology

Analyte Targeting for NPS Identification in Seized Drugs and Toxicology Analyte Targeting for NPS Identification in Seized Drugs and Toxicology Alex J. Krotulski, MS Research Scientist Center for Forensic Science Research & Education Background Explosion and expansion of NPS

More information

GAS CHROMATOGRAPHY (GC)

GAS CHROMATOGRAPHY (GC) GAS CHROMATOGRAPHY (GC) Pre-Lab Questions Questions are to be answered before the beginning of the laboratory. The answers are due at the beginning of each experiment (the questions are for credit and

More information

Implementation of Methods Translation between Liquid Chromatography Instrumentation

Implementation of Methods Translation between Liquid Chromatography Instrumentation Implementation of Methods Translation between Liquid Chromatography Instrumentation Michael D. Jones, Peter Alden, Kenneth J. Fountain, and Andrew Aubin Waters Corporation, Milford, MA, U.S. APPLICATION

More information

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity Agilent 12 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity A case study with degraded omeprazole drug product Application Note Small Molecule

More information

Quality control analytical methods- Switch from HPLC to UPLC

Quality control analytical methods- Switch from HPLC to UPLC Quality control analytical methods- Switch from HPLC to UPLC Dr. Y. Padmavathi M.pharm,Ph.D. Outline of Talk Analytical techniques in QC Introduction to HPLC UPLC - Principles - Advantages of UPLC - Considerations

More information

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance Michael D. Jones, Marian Twohig, Karen Haas, and Robert S. Plumb Waters Corporation,

More information

Chemists are from Mars, Biologists from Venus. Originally published 7th November 2006

Chemists are from Mars, Biologists from Venus. Originally published 7th November 2006 Chemists are from Mars, Biologists from Venus Originally published 7th November 2006 Chemists are from Mars, Biologists from Venus Andrew Lemon and Ted Hawkins, The Edge Software Consultancy Ltd Abstract

More information

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure. High performance liquid chromatography (HPLC) is a much more sensitive and useful technique than paper and thin layer chromatography. The instrument used for HPLC is called a high performance liquid chromatograph.

More information

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology Gas Chromatography/Mass Spectrometry Author Harry Prest 1601 California Avenue

More information

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC Online Reaction Monitoring of In- Manufacturing Samples by UPLC Tanya Tollifson Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Better throughput, yield, and process understanding are possible

More information

ACD/Structure Elucidator

ACD/Structure Elucidator ACD/Structure Elucidator ver a Decade of Development in Computer Assisted Structure Elucidation Visionary Software Advancing Research A Case for CASE Computer-Assisted Structure Elucidation (CASE) is an

More information

Chapter 20: Identification of Compounds

Chapter 20: Identification of Compounds Chemists are frequently faced with the problem of identifying unknown compounds. Environmental scientists may have to identify pollutants in soils and water, synthetic chemists may want to confirm that

More information

Instrumental Chemical Analysis

Instrumental Chemical Analysis L1 Page1 Instrumental Chemical Analysis Dr. Ahmad Najjar Philadelphia University Faculty of Pharmacy Department of Pharmaceutical Sciences 2 nd semester, 2016/2017 L1 Page2 Course Syllabus Course title:

More information

MassHunter TOF/QTOF Users Meeting

MassHunter TOF/QTOF Users Meeting MassHunter TOF/QTOF Users Meeting 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks

More information

The Theory of HPLC. Quantitative and Qualitative HPLC

The Theory of HPLC. Quantitative and Qualitative HPLC The Theory of HPLC Quantitative and Qualitative HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference

More information

In Part I of this series, we saw how different tautomeric

In Part I of this series, we saw how different tautomeric Tautomerism and Expert Systems in Spectroscopy Part II: Assigning the Correct Tautomers Using NMR Spectral Predictors and IR Structure Spectrum Verification Tools Because tautomers are closely related

More information

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46> High Performance Liquid Chromatography HPLC-9 Ultra-high Speed Analysis of Ibuprofen within USP Allowed Limits by Nexera Method Scouting In recent years, high-throughput analytical techniques have

More information

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF Application Note Donghui Yi and Christine Miller Jon D. Williams, GlaxoSmithKline Introduction Mass spectrometry (MS) has become a core technology

More information

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace_Rev3 Introducing

More information

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note Authors Chris Sandy Agilent Technologies Wokingham, Berkshire, UK Jean-Francois Garnier Agilent Technologies

More information

Glyphosate in all its forms

Glyphosate in all its forms Glyphosate in all its forms S. Goscinny and V. Hanot Scientific Institute for Public Health Pesticides Unit A breakthrough molecule Since its first appearance on the market in 1974, glyphosate has become

More information

STEM Research Literacy

STEM Research Literacy STEM Research Literacy Are We Adequately Preparing Our STEM Graduates for Positions in Laboratory Research in Academia and Industry? Graeme Whitley Agenda What Prompted This? Wiley Science Solutions Wiley

More information

Automatization for development of HPLC methods

Automatization for development of HPLC methods Fresenius J Anal Chem (2001) 369 : 36 41 Springer-Verlag 2001 SPECIAL ISSUE PAPER M. Pfeffer H. Windt Automatization for development of HPLC methods Received: 31 May 2000 / Revised: 13 July 2000 / Accepted:

More information

The shortest path to chemistry data and literature

The shortest path to chemistry data and literature R&D SOLUTIONS Reaxys Fact Sheet The shortest path to chemistry data and literature Designed to support the full range of chemistry research, including pharmaceutical development, environmental health &

More information

Guide to Peptide Quantitation. Agilent clinical research

Guide to Peptide Quantitation. Agilent clinical research Guide to Peptide Quantitation Agilent clinical research Peptide Quantitation for the Clinical Research Laboratory Peptide quantitation is rapidly growing in clinical research as scientists are translating

More information

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative. We don t have anything against mass spectrometry. We just think it s time for a worthy alternative. gas chromatography detector Everything you need in one GC detector Universal and selective detector with

More information

Characterization of Odor & Taste Components Using Olfactory Detection and Solid Phase Microextraction GC-MS

Characterization of Odor & Taste Components Using Olfactory Detection and Solid Phase Microextraction GC-MS Characterization of Odor & Taste Components Using Olfactory Detection and Solid Phase Microextraction GC-MS By Amy Porter, Ph.D., Operations Manager, Impact Analytical and Karen Griffin, Senior Analytical

More information

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis Technical Overview Introduction Metabolomics studies measure the relative abundance of metabolites

More information

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides Abstract Here we describe a two-step QC procedure for synthetic peptides. In the first step, the

More information

IR-LC Deposition and Detection System. Polymer Deformulation and Additive Analysis by a Single GPC-IR Run

IR-LC Deposition and Detection System. Polymer Deformulation and Additive Analysis by a Single GPC-IR Run DiscovIR-GPC DiscovIR-L IR-LC Deposition and Detection System Application Note 42 Polymer Deformulation and Additive Analysis by a Single GPC-IR Run ABSTRACT This application note describes the use of

More information

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract. Separation of Explosives in EPA 833: Column Choices Optimize Speed, Resolution, and Solvent Use Application Environmental Authors John W. Henderson Jr. and William J. Long Agilent Technologies, Inc. 28

More information

Understanding Your Spectra Module. Agilent OpenLAB CDS ChemStation Edition

Understanding Your Spectra Module. Agilent OpenLAB CDS ChemStation Edition Understanding Your Spectra Module Agilent OpenLAB CDS ChemStation Edition Notices Agilent Technologies, Inc. 1994-2012, 2013 No part of this manual may be reproduced in any form or by any means (including

More information

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative. We don t have anything against mass spectrometry. We just think it s time for a worthy alternative. gas chromatography detector New directions in science are launched by new tools much more often than

More information

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone Mia Summers and Kenneth J. Fountain Waters Corporation, 34 Maple St.,

More information

WALKUP LC/MS FOR PHARMACEUTICAL R&D

WALKUP LC/MS FOR PHARMACEUTICAL R&D Pharmaceutical Workflow Solutions WALKUP LC/MS FOR PHARMACEUTICAL R&D Chemists, Peptide/Protein Chemists, Biologists, and Beyond MASSHUNTER WALKUP A Single User Interface for Robust and Reliable LC/MS

More information

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies MS n Analysis With Fast Polarity Switching in the Agilent Series LC/MSD Trap SL Application Note Christine Miller Introduction During mass spectrometric analysis, many compounds respond better to a particular

More information

Automating Gradient Method Development in Flash Chromatography For Greater Productivity and Minimizing Solvent Use

Automating Gradient Method Development in Flash Chromatography For Greater Productivity and Minimizing Solvent Use Automating Gradient in Flash For Greater Productivity and Minimizing Solvent Use Melissa Wilcox, Rakesh Bose, Scott Anderson, Kathy Lawrence Grace Davison Discovery Sciences 251 Waukegan Rd. Deerfield

More information

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity Janet Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS High

More information

Intelligent NMR productivity tools

Intelligent NMR productivity tools Intelligent NMR productivity tools Till Kühn VP Applications Development Pittsburgh April 2016 Innovation with Integrity A week in the life of Brian Brian Works in a hypothetical pharma company / university

More information

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS Application Note Forensic Toxicology Authors Martin Josefsson, and Markus Roman National Board of Forensic Medicine Linköping,

More information

Implementing ACD/Automation Server Processing with Micro Flow-Injection and Open-Access NMR

Implementing ACD/Automation Server Processing with Micro Flow-Injection and Open-Access NMR Implementing ACD/Automation Server Processing with Micro Flow-Injection and Open-Access NMR Steve Hollis Amgen Inc. Cambridge, MA March 23, 2014 1 Overview Amgen has been using ACD/Labs software as the

More information

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION A purpose-built collection of the best-inclass components for forensic toxicology Whether you re challenged to present reliable and secure forensic sample

More information

Accurate Mass Analysis of Hydraulic Fracturing Waters

Accurate Mass Analysis of Hydraulic Fracturing Waters Application Note Environmental Accurate Mass Analysis of Hydraulic Fracturing Waters Using the Kendrick mass defect with the Agilent LC/Q-TOF MS Authors E. Michael Thurman and Imma Ferrer Department of

More information

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents Marco Karsten, Bas, Dolman, Giovanni Maio, Frank Steiner, Holger Franz, Frank Arnold and Remco Swart LC Packings,

More information

Automated LC Method Development: Fundamentals and Columns, Hardware, and Software

Automated LC Method Development: Fundamentals and Columns, Hardware, and Software An Executive Summary Automated LC Method Development: Fundamentals and Columns, Hardware, and Software Dr. William Long Application Scientist in the LC Columns marketing group Agilent Technologies Andreas

More information

Automated method development using Agilent 1100 Series HPLC systems, Agilent ChemStation and ChromSword software. Application

Automated method development using Agilent 1100 Series HPLC systems, Agilent ChemStation and ChromSword software. Application Automated method development using Agilent 1100 Series HPLC systems, Agilent ChemStation and ChromSword software Application Sergey Galushko Ralf Honsberg Abstract The development of an HPLC method is

More information

4 Job Postings Selected

4 Job Postings Selected Brigham Young University Idaho 4 Job Postings Selected https://byui csm.symplicity.com/utils/batchprintjobs.php?&sesskey=manager_jobs nosub_smpl_jobs 1/7 Sr Analyst Desired Major(s): College of Physical

More information

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS ESPRIT Feature Particle detection and chemical classification Innovation with Integrity EDS Fast and Comprehensive Feature Analysis Based on the speed and accuracy of the QUANTAX EDS system with its powerful

More information

Application Note. Edgar Naegele. Abstract

Application Note. Edgar Naegele. Abstract Fast identification of main drug metabolites by quadrupole time-of-flight LC/MS Measuring accurate MS and MS/MS data with the Agilent 651 Q-TOF LC/MS and identification of main meta-bolites by comparison

More information

Chapter content. Reference

Chapter content. Reference Chapter 7 HPLC Instrumental Analysis Rezaul Karim Environmental Science and Technology Jessore University of Science and Technology Chapter content Liquid Chromatography (LC); Scope; Principles Instrumentation;

More information

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining Dave Weil, Ph.D. and Jim Lau, Ph.D. Typical Method Conditions: 1260 UHPLC

More information

CHEM Experiment Five Gas Chromatographic Analysis Of A Phenolic Extract. Objectives:

CHEM Experiment Five Gas Chromatographic Analysis Of A Phenolic Extract. Objectives: CHEM 3281 Experiment Five Gas Chromatographic Analysis Of A Phenolic Extract Objectives: The objectives of this experiment are: 1. to evaluate the fundamental parameters of gas chromatography; 2. to identify

More information

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION Quantitation by High Resolution Mass Spectrometry: Using Target Enhancement and Tof-MRM to Achieve Femtogram-level On-column Sensitivity for Quantitation of Drugs in Human Plasma Yun W. Alelyunas, Mark

More information

Pittcon P

Pittcon P PO-CON1701E 76% Increase in Throughput for Determination of Semi-Volatiles Using Narrow-Bore GC Columns and Rapid Data Acquisition with a Highly Sensitive Quadrupole GCMS System Pittcon 2017 1440-14P Brahm

More information

Supporting Information. Labeled Ligand Displacement: Extending NMR-based Screening of Protein Targets

Supporting Information. Labeled Ligand Displacement: Extending NMR-based Screening of Protein Targets Supporting Information Labeled Ligand Displacement: Extending NMR-based Screening of Protein Targets Steven L. Swann, Danying Song, Chaohong Sun, Philip J. Hajduk, and Andrew M. Petros Global Pharmaceutical

More information

Philadelphia University Faculty of Pharmacy Department of Pharmaceutical Sciences First (Fall) semester, 2011/2012. Course code:

Philadelphia University Faculty of Pharmacy Department of Pharmaceutical Sciences First (Fall) semester, 2011/2012. Course code: Philadelphia University Faculty of Pharmacy Department of Pharmaceutical Sciences First (Fall) semester, 2011/2012 Course syllabus Course title: Pharmaceutical Instrumental Analysis Course level: Third

More information

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES JPACSM 127 AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES Trace Analytical Inc. Menlo Park, CA ABSTRACT GC based gas analyzers with Reduction Gas Detector (RGD) and Flame Ionization

More information

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS TargetScreener A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS TargetScreener Get the Complete Picture Forensic laboratories are frequently required to perform

More information

Compounding insights Thermo Scientific Compound Discoverer Software

Compounding insights Thermo Scientific Compound Discoverer Software Compounding insights Thermo Scientific Compound Discoverer Software Integrated, complete, toolset solves small-molecule analysis challenges Thermo Scientific Orbitrap mass spectrometers produce information-rich

More information

Reducing False Positives with Automated NMR Verification. Ryan Sasaki NMR Product Manager SMASH 2011

Reducing False Positives with Automated NMR Verification. Ryan Sasaki NMR Product Manager SMASH 2011 Reducing False Positives with Automated NMR Verification Ryan Sasaki NMR Product Manager SMASH 2011 Why Not More NMR? Cost $$$ NMR > LC-MS > GC-MS 1 Sample requirements/sensitivity Tougher to interpret

More information

OF ALL THE CHEMISTRY RELATED SOFTWARE

OF ALL THE CHEMISTRY RELATED SOFTWARE ChemBioOffice Ultra 2010 - A Great Benefit for Academia by Josh Kocher, Illinois State University OF ALL THE CHEMISTRY RELATED SOFTWARE that I have used in both an industrial and academic setting, ChemBioOffice

More information

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis Keywords: Automated GX-271 GPC Clean-up System, Contaminants,

More information

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Application Note Authors Kevin McCann, Sameer Nene, Doug McIntyre, Edmond Neo, Dennis Nagtalon, and

More information

Automated and accurate component detection using reference mass spectra

Automated and accurate component detection using reference mass spectra TECHNICAL NOTE 72703 Automated and accurate component detection using reference mass spectra Authors Barbara van Cann 1 and Amit Gujar 2 1 Thermo Fisher Scientific, Breda, NL 2 Thermo Fisher Scientific,

More information

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy Introduction to Fourier Transform Infrared Spectroscopy Introduction What is FTIR? FTIR stands for Fourier transform infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR

More information

Flash chromatography purification of high pka organic compounds with Teledyne Isco s specialty RediSep columns

Flash chromatography purification of high pka organic compounds with Teledyne Isco s specialty RediSep columns Flash chromatography purification of high pka organic compounds with Teledyne Isco s specialty RediSep columns Mikael Mahler*, Veronica Thomason, and John Urh Teledyne Isco Inc., P.O. Box 82531, Lincoln

More information

Natural Products. Innovation with Integrity. High Performance NMR Solutions for Analysis NMR

Natural Products. Innovation with Integrity. High Performance NMR Solutions for Analysis NMR Natural Products High Performance NMR Solutions for Analysis Innovation with Integrity NMR NMR Spectroscopy Continuous advancement in Bruker s NMR technology allows researchers to push the boundaries for

More information

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM Application Note: 320 Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM Key Words Metabolism Study Structure Elucidation Metabolite ID Mass Frontier Chromatography

More information

Introduction to E&Ls 1

Introduction to E&Ls 1 Introduction to E&Ls 1 Overview What industries need to determine E&Ls Define extractables and leachables Basic overview of an E&L study Regulatory landscape 2 A leader in plastics analysis Jordi Labs

More information

Deposition and Detection System. Trace Level Analysis of Chemical Warfare Agents (CWAs) Related Chemicals by GC-IR Solid Phase System

Deposition and Detection System. Trace Level Analysis of Chemical Warfare Agents (CWAs) Related Chemicals by GC-IR Solid Phase System DiscovIR-GPC DiscovIR-GC Deposition and Detection System Application Note 41 Trace Level Analysis of Chemical Warfare Agents (CWAs) Related Chemicals by GC-IR Solid Phase System ABSTRACT The DiscovIR-GC

More information

Peptide Isolation Using the Prep 150 LC System

Peptide Isolation Using the Prep 150 LC System Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System, an affordable, highly reliable system for preparative chromatography, is suitable

More information

An Automated Application Template for Dissolution Studies

An Automated Application Template for Dissolution Studies An Automated Application Template for Dissolution Studies in SDMS Vision Publisher Wolfgang Lemmerz, Chris L. Stumpf, Thomas Schmidt, and Phil Kilby Waters Corporation, Milford, MA U.S.A. OVERVIEW Dissolution

More information

Analytical Roche Benefits and Hurdles of ACD Software. Josef Schneider ACD/Labs Symposium on Laboratory Intelligence Jun 19-20, 2013

Analytical Roche Benefits and Hurdles of ACD Software. Josef Schneider ACD/Labs Symposium on Laboratory Intelligence Jun 19-20, 2013 Analytical Chemistry @ Roche Benefits and Hurdles of ACD Software Josef Schneider ACD/Labs Symposium on Laboratory Intelligence Jun 19-20, 2013 Drug Discovery "Making discoveries that matter" MedChem,

More information

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION Andrew J. Aubin and Tanya L. Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Benzocaine (4-Aminobenzoic

More information

Chromatographic Separation

Chromatographic Separation What is? is the ability to separate molecules using partitioning characteristics of molecule to remain in a stationary phase versus a mobile phase. Once a molecule is separated from the mixture, it can

More information

Reaxys The Highlights

Reaxys The Highlights Reaxys The Highlights What is Reaxys? A brand new workflow solution for research chemists and scientists from related disciplines An extensive repository of reaction and substance property data A resource

More information

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Application Note # CA 284780 Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Abstract The analysis of semi-volatile organic compounds

More information

FACULTY OF PHARMACY. M. Pharmacy I Semester (Suppl.) Examination, November 2015 (Common To All) Subject: Pharmaceutical Analytical Techniques

FACULTY OF PHARMACY. M. Pharmacy I Semester (Suppl.) Examination, November 2015 (Common To All) Subject: Pharmaceutical Analytical Techniques M. Pharmacy I Semester (Suppl.) Examination, November 2015 (Common To All) Subject: Pharmaceutical Analytical Techniques Code No. 6001 / S Note: Answer any Five questions. All questions carry equal marks.

More information

Application. Gas Chromatography February Introduction

Application. Gas Chromatography February Introduction Ambient Headspace Analysis with the Agilent 7683 Automatic Liquid Sampler Application Gas Chromatography February 1998 Authors Matthew S. Klee and Chin Kai Meng Agilent Technologies, Inc. 2850 Centerville

More information

ApplicationNOTE EXACT MASS GC/MS ANALYSIS OF AMINE MONOMERS USED IN COMBINATORIAL LIBRARY PRODUCTION

ApplicationNOTE EXACT MASS GC/MS ANALYSIS OF AMINE MONOMERS USED IN COMBINATORIAL LIBRARY PRODUCTION ApplicationOTE EXACT MASS GC/MS AALYSIS O AMIE MOOMERS USED I COMBIATORIAL LIBRARY PRODUCTIO Robert L. Johnson 1, Robert Wiethe 2, William Stuart 2, Peter Hancock 3 and Anthony ewton 3 1 GlaxoSmithKline,

More information

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate Michael D. Jones, Xiang Jin Song, Robert S. Plumb, Peter J. Lee, and

More information

New happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist

New happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist New happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist Genie-2000 Latest Features Cascade Summing Correction LACE (Line Activity Consistency Evaluator) Interactive Nuclide

More information

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry Improving ADME Screening Productivity in Drug Discovery INTRODUCTION Improving the quality of the decisions made at the drug discovery stage can profoundly impact the efficiency of the drug discovery and

More information

Substance Characterisation for REACH. Dr Emma Miller Senior Chemist

Substance Characterisation for REACH. Dr Emma Miller Senior Chemist Substance Characterisation for REACH Dr Emma Miller Senior Chemist Submission of a REACH registration dossier, either as a lead registrant or a joint registrant Submission of an Inquiry to ECHA Submission

More information