Sicherheit zuverlässig produziert.

Size: px
Start display at page:

Download "Sicherheit zuverlässig produziert."

Transcription

1 Sicherheit zuverlässig produziert.

2 Table of content Comparison between analysers Sycon 2502 and Sycon Analysers for measuring and monitoring water ingredients 5 Sycon 2502 total hardness / carbonate hardness... 5 Sycon 2800 total hardness / carbonate hardness... 6 Sycon 2800 Select determination of water ingredients (e.g.: EDTA concentration)... 7 Accessories for analysers Sycon 2500 / 2501 / 2502 / 2800 / Cleaning supplies... 8 Maintenance sets... 8 Controller for ion exchanger and filtration plants 9 HAcon HAcon Pilot distributors 10 PVcon PVcon Cooler 11 Sample coolers Pre-coolers Reagents for analysers Sycon 2500 / 2501 / 2502 / Residual / total hardness Carbonate hardness Iron content EDTA concentration Reagents for analyser Sycon 3000 (A) 15 Residual / total hardness Carbonate hardness Iron content Reagents for analysers Testomat-FG / -F-BOB / 808 (company Heyl) 16 Residual / total hardness Reagents for analysers Testomat-C-BOB (company Heyl) 17 Carbonate hardness Minus m-value Reagents for analysers Testomat 2000 / ECO (company Heyl) 18 Residual / total hardness Carbonate hardness Safety reliably produced.

3 Table of content Test kits for water analysis based on limit monitoring method 19 Residual hardness Test kits for water analysis based on titration method 20 Total hardness (1 reagent) Total hardness (1 reagent, 1 titration solution) Sulfite (3 reagents) PM-value (3 reagents) Test kits for water analysis based on colorimetric method 23 Aluminium (0,05 2 mg/l Al) Chlorine LR (0,05 1,0 mg/l Cl2) Chlorine dioxide (0,05 0,5 mg/l Cl2) Chlorine / Chlorine dioxide (0,05 0,5 mg/l Cl2) DEHA (0,05 1,0 mg/l DEHA) Iron LR (0,05 1,0 mg/l Fe) Iron LRS (0,01 0,5 mg/l Fe) Iron HR (0,25 10 mg/l Fe) Iron HRS (0,2 10 mg/l Fe) Manganese (0,03 1,0 mg/l Mn) Nitrate (1 50 mg/l NO3 - ) ph 2-5 (2 5 ph) ph 5-8 (5 8 ph) ph 8-12 (8 12 ph) ph- Chlorine (free) Phosphate LR (0,25 10 mg/l PO4 3- ) Phosphate HR (2,5 100 mg/l PO4 3- ) Silicate (0,25 10 mg/l SiO2) Sulfide (0,05 1,0 mg/l S 2- ) Sulfite (0,5 20 mg/l SO3 2- ) Conversion of the units of water hardness dh e fh ppm mval/l mmol/l German degree 1 dh = 1 1,253 1,78 17,8 0,357 0,1783 English degree 1 e = 0, ,43 14,3 0,285 0,142 French degree 1 fh = 0,56 0, ,2 0,1 ppm CaCO3 (USA) 1 ppm = 0,056 0,07 0,1 1 0,02 0,01 mval/l earth alkali ions 1 mval/l = 2,8 3, ,5 mmol/l earth alkali ions 1 mmol/l = 5,6 7, The unit 1 ppm is used here as opposed to the actual meaning of the word in term of 1 mg/l CaCO3.

4 Comparison between analysers Sycon 2502 and Sycon 2800 We offer analysis technology fitting your requirements. Please choose the one which meets your requirements. Sycon 2502 The Sycon 2502 is an analysis device for monitoring the limit value. The limit value is defined by the used reagent and is controlled in a constant time interval. When the limit value is exceeded, a signal is transferred to the control system. Sycon 2800 Beyond that, the Sycon 2800 offers further functions and more detailed information regarding your process water. It measures the exact water hardness and indicates the actual value on the display. A multiplicity of connections is available for further processing of the measured values and the control of the unit. In addition to time and volume controlled analysis intervals you can program two limit values that are independent from each other. Both analysers are characterised by following key features: Maintenance-free full colour sensor No tools needed for maintenance of measuring chamber More than 5000 analyses per bottle of reagent Characteristics Sycon 2502 Sycon 2800 Simple commissioning Intuitive operation Low maintenance Self-calibrating Diagnosis programme Time controlled analysis interval Volume controlled analysis interval - Measured value graph of the last analyses Measured value protocol on SD-card - CAN port - Analogue output ( ma) - Relay function Limit value 1 Limit value 2 - Analysis active / cooling water Ready for operation BOB warning Input function Current monitor External analysis start Analysis abort - Water counter - Range of monitoring Sycon 2502 Sycon 2800 Total hardness 0, dh 0, dh ,8 µmol/l µmol/l Carbonate hardness dkh 0, dkh 3, ,7 µmol/l 1 21,4 µmol/l Shelf life time of reagent 24 months 24 months Safety reliably produced. 4

5 Analysers for measuring and monitoring water ingredients Sycon 2502 total hardness / carbonate hardness Monitoring by controlling the limit value for demand actuated regeneration activation (e.g.: monitoring of the recirculation of condensate in the boiler house) Maintenance-free full colour sensor No tools needed for maintenance of measuring chamber More than 5000 analyses per bottle of reagent Monitoring of one limit value Alarm of lack of reagent / BOB-functionality LED status display Language neutral Analysis start options: o Automatically by time interval o Suppressing of analysis via external switch o Analysis via external controller 3 potential free outputs: o Exceedance of limit value o Malfunction of device o Analysis active (e.g.: valve of a sample cooler) 1 contact input for external controller or current switch The limit is set by the used reagent: Residual- and total hardness dh 0,02 / 0,05 / 0,1 / 0,2 / 0,3 / 0,5 / 1,0 / 2,0 / 3,0 / 5,0 Carbonate hardness dh 1,0 / 1,5 / 2,0 / 3,0 Article name Article No. Voltage Memo Sycon 2502 Analyser on wall mounting plate V Sycon 2501/2502/2800 housing Maintenance set Article name Article No. Memo Maintenance set for Sycon 2500 / 2501 / Pressure reducing strainer for inlet pressure > 4 bar Appropriate reagents, see page 13. 5

6 Analysers for measuring and monitoring water ingredients Sycon 2800 total hardness / carbonate hardness Fully automated determination of water hardness (e.g.: supervision of water intersection) Maintenance-free full colour sensor No tools needed for maintenance of measuring chamber More than 5000 analyses per bottle of reagent Free selectable limit values in the range of reagent Alarm in case of lack of reagent / BOB-functionality Graphic display (illuminated) Various languages Analysis start: o Automatically by time interval o Suppressing of analysis via current switch o Via external controller 4 potential free outputs: o Exceedance of limit value 1 o Exceedance of limit value 2 alternatively lack of reagent o Malfunction of device o Analysis active (e.g.: valve of a sample cooler) 2 contact inputs for external controller or current switch Article name Article No. Voltage Memo Sycon 2800 Analyser on wall mounting plate V Sycon 2800 Analyser on wall mounting plate V Sycon 2501/2502/2800 housing Maintenance set Article name Article No. Memo Maintenance set for Sycon Pressure reducing strainer for inlet pressure > 4 bar Appropriate reagents, see page 13. Safety reliably produced. 6

7 Analysers for measuring and monitoring water ingredients Sycon 2800 Select determination of water ingredients (e.g.: EDTA concentration) Fully automated determination of water ingredients which is set by the chosen reagent Maintenance-free full colour sensor No tools needed for maintenance of measuring chamber More than 5000 analyses per bottle of reagent Free selectable limit values in the range of reagent Alarm in case of lack of reagent / BOB-functionality Graphic display (illuminated) Various languages Analysis start: o Automatically by time interval o Suppressing of analysis via current switch o Analysis via external controller 4 potential free outputs: o Exceedance of limit value 1 o Exceedance of limit value 2 alternatively lack of reagent o Malfunction of device o Analysis active (e.g.: valve of a sample cooler) 2 contact inputs for external controller or current switch Article name Article No. Voltage Memo Sycon 2800 Select Analyser on wall mounting plate V Sycon 2800 Select Analyser on wall mounting plate V Sycon 2501/2502/2800 housing Maintenance set Article name Article No. Memo Maintenance set for Sycon Pressure reducing strainer for inlet pressure > 4 bar Appropriate reagents, see page 13. 7

8 Accessories for analysers Sycon 2500 (A) / 2501 (A) / 2502 / 2800 / 3000 (B) Cleaning supplies Sycon Clean Cleaning set for acrylic measuring chambers FIT 3000 Cleaning fluid for acrylic measuring chambers (Cleaning fluid FIT 3000, 5 pairs of gloves, 2 brushes, funnel, box, instruction) Article name Article No. Memo Sycon Clean FIT 3000 (1000 ml) Maintenance sets Sycon 2500 / 2501 /2502 Article name Article No. Memo Maintenance set for Sycon 2500 / 2501 / Pressure reducing strainer for inlet pressure > 4 bar Sycon 2800 Article name Article No. Memo Maintenance set for Sycon Pressure reducing strainer for inlet pressure > 4 bar Sycon 3000 Article name Article No. Memo Maintenance set 01 for Sycon 3000 (all replacement hoses 3 x) Maintenance set 06 for Sycon 3000 for ½ year of operation (hoses, seals, bearings, wire, connectors) Maintenance set 24 for Sycon 3000 for 2 years of operation (4 x maintenance set 06 plus plugs and additional seals) (A) The Sycon 2500 and 2501 are discontinued analysis devices which are replaced by the Sycon (B) The Sycon 3000 is a discontinued analysis device which is replaced by the Sycon Safety reliably produced. 8

9 Controller for ion exchanger and filtration plants HAcon 7000 Controller unit used for backwashing filter systems or iron exchange resign in conjunction with pilot distributors or remote control valves Real-time clock, backed with lithium cell against voltage failure Storage of the last 10 regeneration points in time Timed controlled or via switch / analyser Regeneration release: o Points in time o Time intervals o external (differential pressure) or by hand Connections: o 2 remote control valves (pilot distributor) o 2 service valves o 1 programmable output o 2 programmable inputs o external (differential pressure) or by hand Article name Article No. Voltage Memo HAcon V HAcon V HAcon V HAcon /24 V HAcon 8000 Controller unit used for backwashing filter systems or iron exchange resign in conjunction with pilot distributors or remote control valves functional range extended by an additional output compared to the HAcon 7000 Real-time clock, backed with lithium cell against voltage failure Storage of the last 10 regeneration points in time Timed controlled or via switch / analyser Regeneration release: o Points in time o Time intervals o external (differential pressure) or by hand Connections: o 2 remote control valves (pilot distributor) o 2 service valves o 2 programmable output o 2 programmable inputs o external (differential pressure) or by hand Article name Article No. Voltage Memo HAcon V HAcon V HAcon V HAcon /24 V 9

10 Pilot distributors PVcon 5000 Controller for ion-exchanger and filtration plants Operation mode adjustable for ion exchanger or filter system Control in pulse or alternating operation Synchronisation switch included Control medium air or water Output of position to a current interface ( ma) 6 relays for indication of valves states (replaces the add-on programs of previous models) Rotary valve made of stainless steel Article name Membrane valve Article No. Voltage Memo PVcon 5000 pressure-less open V PVcon 5000 pressure-less open V PVcon 5000 pressure-less closed V PVcon 5000 pressure-less closed V PVcon 5000 Dual without spring reset V PVcon 5000 Dual without spring reset V PVcon 7000 Controller for ion-exchanger and filtration plants - functional range extended by an integrated control compared to the PVcon 5000 Operation mode adjustable for ion exchanger or filter system adjustable Volume, time or externally controlled triggering programmable Synchronisation switch included Start of regeneration programmable by analyser or via input contact Output of position to a current interface ( ma) 6 relays for indication of valves states (replaces the add-on program of previous models) Rotary valve made of stainless steel Article name Membrane valve Article No. Voltage Memo PVcon 7000 pressure-less open V PVcon 7000 pressure-less open V PVcon 7000 pressure-less closed V PVcon 7000 pressure-less closed V Safety reliably produced. 10

11 Cooler Sample coolers Suitable for abstraction of water samples in the boiler house Cooling water input 8 mm Cooling water output ½ external thread Sample water input 8 mm Sample water output 8 mm Material stainless steel , electro-polished Rated pressure 8 bar Cooling coil 16 bar AC 100 AC 400 HWV 100 KWV 150 HWV 400 KWV 400 Available in 2 sizes with or without hot and cold water valves Article name Article No. Memo Sample cooler Type AC 100 without valves Corpus: 100 mm x 225 mm, Cooling coil: 2,6 m x 8 mm Sample cooler Type AC 100 with hot and cold water valves Corpus: 100 mm x 225 mm, Cooling coil: 2,6 m x 8 mm Hot water valve Type HWV 100 for sample cooler AC 100 Fine adjustment valve made out of brass, PN 50 bar, 100 C Cold water valve Type KWV 150 for sample cooler AC 100 ¼" ball valve nickel plated brass with fittings for 8 mm tube Sample cooler Type AC 400 without valves Corpus: 100 mm x 448 mm, Cooling coil: 5 m x 8 mm Sample cooler Type AC 400 with hot and cold water valves Corpus: 100 mm x 448 mm, Cooling coil: 5 m x 8 mm Hot water valve Type HWV 400 for sample cooler AC 400 PN 200 bar, 250 C, with fittings for 8 mm tube

12 Cooler Pre-coolers Cooling of flow rate / heat exchanger (e.g.: in connection with analysis devices) Connectors 8 mm for squeezing fitting Material stainless steel , electro-polished Rated pressure of coil 16 bar Corpus 8 bar PC 200 PC 400 Available in 2 sizes Article name Article No. Memo Pre-Cooler Type PC 200 Corpus: 100 mm x 225 mm, Cooling coil: 2,6 m x 8 mm Pre-Cooler Type PC 400 Corpus: 100 mm x 448 mm, Cooling coil: 5 m x 8 mm Safety reliably produced. 12

13 Reagents for analysers Sycon 2500 (A) / 2501 (A) / 2502 / 2800 Residual / total hardness Shelf life 24 months For analysers Sycon 2500 / 2501 / 2502 / 2800 As single bottle of or as advantage pack with 4 x Article name Single bottle Advantage pack Reagent H25-0,02 Reagent H25-0,05 Reagent H25-0,1 Reagent H25-0,2 Reagent H25-0,3 Reagent H25-0,5 Reagent H25-1 Reagent H25-2 Reagent H25-3 Reagent H25-5 Reagent H x x x x x x x x x x x Limit value Sycon 250x 0,02 dh 0,36 ppm 0,036 f 0,025 e 0,05 dh 0,9 ppm 0,089 f 0,063 e 0,1 dh 1,8 ppm 0,18 f 0,13 e 0,2 dh 3,6 ppm 0,36 f 0,25 e 0,3 dh 5,3 ppm 0,53 f 0,38 e 0,5 dh 8,9 ppm 0,89 f 0,63 e 1 dh 17,8 ppm 1,78 f 1,25 e 2 dh 35,6 ppm 3,56 f 2,5 e 3 dh 53,4 ppm 5,34 f 3,76 e 5 dh 89 ppm 8,9 f 6,3 e 10 dh 178 ppm 17,8 f 12,5 e Measuring range Sycon ,02 0,12 dh 0,36 2,13 ppm 0,036 0,213 f 0,025 0,150 e 0,02 0,2 dh 0,36 3,56 ppm 0,036 0,36 f 0,025 0,25 e 0,03 0,3 dh 0,543 5,43 ppm 0,054 0,54 f 0,038 0,37 e 0,06 0,6 dh 1,1 10,6 ppm 0,11 1,06 f 0,08 0,75 e 0,09 0,9 dh 1,6 16,0 ppm 0,16 1,60 f 0,12 1,12 e 0,15 1,5 dh 2,7 26,7 ppm 0,27 2,67 f 0,19 1,87 e 0,3 3 dh 5,34 53,4 ppm 0,54 5,34 f 0,38 3,75 e 0,6 6 dh 10,7 106 ppm 1,07 10,6 f 0,76 7,51 e 0,9 9 dh 16,0 160 ppm 1,61 16,0 f 1,13 11,2 e 1,5 15 dh 26,7 267 ppm 2,67 26,7 f 1,88 18,8 e 3 30 dh 53,4 534 ppm 5,34 53,4 f 3,76 37,6 e Memo (A) The Sycon 2500 and 2501 are discontinued analysis devices which are replaced by the Sycon

14 Reagents for analysers Sycon 2500 (A) / 2501 (A) / 2502 / 2800 Carbonate hardness Shelf-life 24 months For analysers Sycon 2500 / 2501 / 2502 / 2800 Article name Single bottle Advantage pack Reagent C25 1 Reagent C25 1,5 Reagent C25 2 Reagent C x x x x Limit value Sycon 250x 1 dh 17,8 ppm CaCO3 1,78 f 1,25 e 1,5 dh 26,7 ppm CaCO3 2,67 f 1,88 e 2 dh 35,6 ppm CaCO3 3,56 f 2,5 e 3 dh 53,4 ppm CaCO3 5,34 f 3,76 e Measuring range Sycon ,3 3 dh 5,34 53,4 ppm 0,54 5,34 f 0,38 3,75 e 0,45 4,5 dh 8,0 80,1 ppm 0,8 8,0 f 0,56 5,6 e 0,6 6 dh 10,7 106 ppm 1,07 10,6 f 0,76 7,51 e 0,9 9 dh 16,0 160 ppm 1,61 16,0 f 1,13 11,2 e Memo Iron content Shelf-life 24 months For analysers Sycon 2500 Fe / 2501 Fe Article name Reagent Fe LRS Reagent Fe HRS Single bottle Limit value Sycon 2500 Fe / Sycon 2501 Fe 0,03 / 0,05 / 0,1 / 0,2 / 0,3 / 0,4 / 0,5 / 0,6 mg/l 0,3 / 0,5 / 1,0 / 2,0 / 3,0 / 4,0 / 5,0 / 6,0 mg/l Memo EDTA concentration Shelf-life 12 months For analyser Sycon 2800 Select Article name Single bottle Measuring range Memo Reagent E ppm (A) The Sycon 2500 and 2501 are discontinued analysis devices which are replaced by the Sycon Safety reliably produced. 14

15 Reagents for analyser Sycon 3000 (A) Residual / total hardness Shelf-life 24 months For analyser Sycon 3000 H Article name Single bottle Advantage pack Measuring range Memo 0,02 0,30 dh Reagent HA 0, ,36 5,34 ppm 4 x 0,04 0,53 f 0,03 0,37 e Reagent HA 1,2 Reagent HA 3 Reagent HA 30 Reagent HA x x x x 0,06 1,20 dh 1,07 21,4 ppm 0,11 2,13 f 0,08 1,50 e 0,15 3,00 dh 2,67 53,4 ppm 0,27 5,34 f 0,19 3,76 e 1,5 30,0 dh 26,7 534 ppm 2,67 53,4 f 1,88 37,6 e 3,0 60,0 dh 53, ppm 5,34 106,8 f 3,76 75,2 e Carbonate hardness Shelf-life 24 months For analyser Sycon 3000 C Article name Single bottle Measuring range Memo 0,15 3,00 dh Reagent CA ,67 53,4 ppm 0,27 5,34 f 0,19 3,76 e Reagent CA 9 Reagent CA ,45 9,00 dh 8,0 160 ppm 0,8 16 f 0,56 11,3 e 1,5 30,0 dh 26,7 534,00 ppm 2,67 53,4 f 1,88 37,6 e Iron content Shelf-life 24 months For analyser Sycon 3000 Fe Article name Single bottle Measuring range Memo Reagent FE ml 0,04 4 mg/l Fe (A) The Sycon 3000 is a discontinued analysis device which is replaced by the Sycon 2800 resp. by the Sycon 2800 Select. 15

16 Reagents (A) for analysers Testomat-FG / -F-BOB / 808 (company Heyl) Residual / total hardness Shelf-life 24 months Refill package Article name (compatible with product) Reagent HG 0,02 (Heyl Type 300) Reagent HG 0,05 (Heyl Type 300S) Reagent HG 0,1 (Heyl Type 301) Reagent HG 0,2 (Heyl Type 302) Reagent HG 0,3 (Heyl Type 303) Reagent HG 0,5 (Heyl Type 305) Reagent HG 1 (Heyl Type 310) Reagent HG 2 (Heyl Type 320) Reagent HG 3 (Heyl Type 330) Reagent HG 5 Reagent HG 10 Article No. Content Limit value Memo ml 0,02 dh ,36 ppm 0,036 f x 0,025 e ml 0,05 dh ,9 ppm 0,089 f x 0,063 e ml 0,1 dh ,8 ppm 0,18 f x 0,13 e ml 0,2 dh ,6 ppm 0,53 f x 0,38 e ml 0,3 dh ,3 ppm 0,53 f x 0,38 e ml 0,5 dh ,9 ppm 0,89 f x 0,63 e ml 1 dh ,8 ppm 1,78 f x 1,25 e ml 2 dh ,6 ppm 3,56 f x 2,5 e ml 3 dh ,4 ppm 5,34 f x 3,76 e ml 5 dh ppm 0,89 f x 6,3 e ml 10 dh ppm 17,8 f x 12,5 e (A) These reagents are products of RLS Wacon, which are compatible with mentioned devices of the company Heyl. Safety reliably produced. 16

17 Reagents (A) for analysers Testomat-C-BOB (company Heyl) Carbonate hardness Shelf-life 24 months Refill package Article name (compatible with product) Reagent HC 1 (Heyl Type C10) Reagent HC 1,5 (Heyl Type C15) Reagent HC 2 (Heyl Type C20) Reagent HC 3 (Heyl Type C30) Reagent HC 4 (Heyl Type C40) Single bottle Limit value 1 dh 17,8 ppm 1,78 f 1,25 e 1,5 dh 26,7 ppm 2,67 f 1,87 e 2 dh 35,6 ppm 3,56 f 2,5 e 3 dh 53,4 ppm 5,34 f 3,76 e 4 dh 71,2 ppm 7,12 f 5,0 e Memo Minus m-value Shelf-life 24 months Refill package Article name (compatible with product) Reagent HM 0,1 (Heyl Type M1) Reagent HM 0,3 (Heyl Type M3) Reagent HM 0,5 (Heyl Type M5) Single bottle Limit value Memo ,1 mmol/l 0,3 mmol/l 0,5 mmol/l (A) These reagents are products of RLS Wacon, which are compatible with mentioned devices of the company Heyl. 17

18 Reagents (A) for analysers Testomat 2000 / ECO (company Heyl) Residual / total hardness Shelf-life 12 months Bottle suitable for Testomat 2000 and ECO (analysers of the company Heyl) No decanting required Article name (compatible with product Reagent HT 0,5 (Heyl Type TH 2005) Reagent HT 2,5 (Heyl Type TH 2025) Reagent HT 10 (Heyl Type TH 2100) Reagent HT 25 (Heyl Type TH 2250) Single bottle Advantage pack Measuring range Memo x x x x 0,05 0,5 dh 0,89 8,9 ppm 0,089 0,89 f 0,063 0,63 e 0,25 2,5 dh 4,45 44,5 ppm 0,45 4,45 f 0,31 3,13 e 1,0 10 dh 17,8 178 ppm 1,78 17,8 f 1,25 12,5 e 2,5 25 dh 44,5 445 ppm 4,45 44,5 f 3,13 31,3 e Carbonate hardness Shelf-life 12 months Bottle suitable for Testomat 2000 and ECO (analysers of the company Heyl) No decanting required Article name (compatible with product) Reagent CT 5 (Heyl Type TC 2050) Reagent CT 10 (Heyl Type TC 2100) Single bottle Advantage pack Measuring range Memo x x 0,5 5 dh 8,9 89 ppm 0,89 8,9 f 0,63 6,3 e 1,0 20 dh 17,8 356 ppm 1,78 35,6 f 1,25 25,0 e (A) These reagents are products of RLS Wacon, which are compatible with mentioned devices of the company Heyl. Safety reliably produced. 18

19 Test kits for water analysis based on limit monitoring method For a fast and well-priced monitoring of ion exchangers Limit monitoring method: By adding one drop of reagent you determine whether the water hardness is above or below the limit value. Packing variants: Hinged lid box: Plastic box (103 x 91 x 36 mm 3 ) Folded box (FA): Cardboard box (65 x 45 x 25 mm 3 ) Refill package (NA): Reagents in plastic bag Residual hardness Number of analyses: 250 Duration of analysis: 1 min Description: complexometric titration, 1 reagent Limit value: 0,05 dh RG Hinged lid box RG 5 FA Folded box RG 5 NA Refill package Limit value: 0,1 dh RG Hinged lid box RG 10 FA Folded box RG 10 NA Refill package Limit value: 0,25 dh RG Hinged lid box RG 25 FA Folded box RG 25 NA Refill package Limit value: 0,5 dh RG Hinged lid box RG 50 FA Folded box RG 50 NA Refill package Limit value: 1,0 dh RG Hinged lid box RG 100 FA Folded box RG 100 NA Refill package 19

20 Test kits for water analysis based on titration method Titration method: The reagent is added dropwise to the sample. The measured value is determined by simply counting the drops until the colour changes. Packing variants: Hinged lid box: Plastic box (103 x 91 x 36 mm 3 ) Folded box (FA): Cardboard box (65 x 45 x 25 mm 3 ) Refill package (NA): Reagents in plastic bag Total hardness (1 reagent) Duration of analysis: Description: 1 min complexometric titration Measured value per drop: 0,1 / 0,05 dh (A) GR Hinged lid box GR 10 NA Refill package Number of analyses: 100 at 1 dh Measured value per drop: 0,5 / 0,25 dh (A) GR Hinged lid box GR 50 NA Refill package Number of analyses: 100 at 5 dh Measured value per drop: 1,0 / 0,5 dh (A) GH Hinged lid box GH 100 FA Folded box GH 100 NA Refill package Number of analyses: 100 at 10 dh Total hardness (1 reagent, 1 titration solution) Duration of analysis: Description: 1 min complexometric titration Measured value per drop: 1,0 / 0,5 dh (A) GHT Hinged lid box GHT 100 NA Refill package GHT 100 IN Refill package (reagent solution) GHT 100 TI Refill package (titration solution) Number of analyses: 100 at 10 dh (A) Given value refers to double amount of sample water. Safety reliably produced. 20

21 Test kits for water analysis based on titration method Carbonate hardness (2 reagents) Number of analyses: Duration of analysis: Description: 100 at 5 and 10 dh 1 min Acid-base-titration Measured value per drop: 0,5 / 0,25 dh (A) CH Hinged lid box CH 05 NA Refill package Measured value per drop: 1,0 / 0,5 dh (A) CH Hinged lid box CH 10 FA Folded box CH 10 NA Refill package Calcium (3 reagents) Number of analyses: 100 Duration of analysis: 1 min Description: complexometric titration Measured value per drop: 1,0 dh (A) Calcium Hinged lid box Calcium NA Refill package Chloride (3 reagents) Number of analyses: 100 Duration of analysis: 3 min Description: mercurimetric titration Measured value per drop: 5 mg/l Cl - / drop, 25 mg/l Cl - (A) Chloride Hinged lid box Chloride NA Refill package Chloride AB Refill package (reagent A + B) Chloride TI Refill package (titration solution) Carbonic acid (2 reagents) Number of analyses: 100 Duration of analysis: 1 min Description: Acid-base-titration Measured value per drop: 1 mg/l CO2 Carbonic acid Hinged lid box Carbonic acid 1 NA Refill package 21

22 Test kits for water analysis based on titration method Measured value per drop: 10 mg/l CO2, 5 mg/l CO2 Carbonic acid Hinged lid box Carbonic acid 10 NA Refill package Sulfate (2 reagents, 1 ion exchanger) Number of analyses: 30 Duration of analysis: 2 min Description: Precipitation-titration Measured value per drop: 10 mg/l SO (A), 5 mg/l SO4 Sulfate Hinged lid box Sulfate 10 NA Refill package Sulfate IN Refill package (reagent) Sulfate IA Refill package (ion exchanger) Sulfate TI Refill package (titration solution) Sulfate AT Activator for Sulfate test (250 ml) Measured value per drop: 20 mg/l SO (A), 10 mg/l SO4 Sulfate Hinged lid box Sulfate 20 NA Refill package Sulfate TI Refill package (titration solution) Sulfite (3 reagents) Number of analyses: 100 Duration of analysis: 1 min Description: Jodometric Measured value per drop: 5 mg/l SO3 2-, 2,5 mg/l 2- (A) SO3 Sulfite Hinged lid box Sulfite NA Refill package Sulfite A + B Refill package (reagents A + B) Sulfite TI Refill package (titration solution) PM-value (3 reagents) Number of analyses: 100 Duration of analysis: 1 min Description: Acid-base-titration Measured value per drop: 0,5 (0,25) mmol/l (A) PM-value Hinged lid box PM-value NA Refill package (A) Given value refers to double amount of sample water. Safety reliably produced. 22

23 Test kits for water analysis based on colorimetric method Colorimetric method: The measuring results are determined by comparison with a 6 colour fields chart. Packing variants: Hinged lid box: Plastic box (103 x 91 x 36 mm 3 ) Folded box (FA): Cardboard box (65 x 45 x 25 mm 3 ) Refill package (NA): Reagents in plastic bag Aluminium (0,05 2 mg/l Al) Number of analyses: 150 Colour values: 0,05 mg/l Al 0,1 mg/l Al Duration of analysis: 8 min 0,25 mg/l Al 0,5 mg/l Al Description: Chromazurol S, 3 reagents 0,75 mg/l Al 2,0 mg/l Al Aluminium Hinged lid box Aluminium NA Refill package Chlorine LR (0,05 1,0 mg/l Cl2) Number of analyses: 150 Colour values: 0,05 mg/l Cl2 0,1 mg/l Cl2 Duration of analysis: 1 min 0,25 mg/l Cl2 0,5 mg/l Cl2 Description: DPD, 3 reagents (free and 0,75 mg/l Cl2 1,0 mg/l Cl2 bound) Chloride LR Hinged lid box Chloride LR NA Refill package Chlorine dioxide (0,05 0,5 mg/l Cl2) Number of analyses: 140 Colour values: 0,05 mg/l ClO2 0,1 mg/l ClO2 Duration of analysis: 1 min 0,2 mg/l ClO2 0,3 mg/l ClO2 Description: DPD, 2 reagents (Chlorine 0,4 mg/l ClO2 0,5 mg/l ClO2 dioxide + chlorine) Chlordioxid Hinged lid box Chlordioxid NA Refill package Chlorine / Chlorine dioxide (0,05 0,5 mg/l Cl2) Number of analyses: 150 Colour 0,05 mg/l Cl2/ClO2 0,1 mg/l Cl2/ClO2 Duration of analysis: 1 min values: 0,2 mg/l Cl2/ClO2 0,3 mg/l Cl2/ClO2 Description: DPD, 3 reagents (only chlorine 0,4 mg/l Cl2/ClO2 0,5 mg/l Cl2/ClO2 dioxide or chlorine dioxide + chlorine) Chloride / Chlordioxid Hinged lid box Chloride / Chlordioxid NA Refill package 23

24 Test kits for water analysis based on colorimetric method DEHA (0,05 1,0 mg/l DEHA) Number of analyses: 100 Colour 0,05 mg/l DEHA 0,1 mg/l DEHA Duration of analysis: 5 min values: 0,25 mg/l DEHA 0,5 mg/l DEHA Description: Ferrozine, 2 reagents 0,75 mg/l DEHA 1,0 mg/l DEHA DEHA Hinged lid box DEHA NA Refill package Iron LR (0,05 1,0 mg/l Fe) Number of analyses: 150 Colour 0,05 mg/l Fe 0,1 mg/l Fe Duration of analysis: 4 min values: 0,25 mg/l Fe 0,5 mg/l Fe Description: Ferrozine, 2 reagents 0,75 mg/l Fe 1,0 mg/l Fe Iron LR Hinged lid box Iron LR NA Refill package Iron LRS (0,01 0,5 mg/l Fe) Number of analyses: 100 Colour value: 0,01 mg/l Fe 0,03 mg/l Fe Duration of analysis: 5 min 0,06 mg/l Fe 0,1 mg/l Fe Description: Ferrozine, 1 reagent 0,2 mg/l Fe 0,5 mg/l Fe Iron LRS Hinged lid box Iron LRS NA Refill package Iron HR (0,25 10 mg/l Fe) Number of analyses: 150 Colour 0,25 mg/l Fe 0,5 mg/l Fe Duration of analysis: 3 min values: 1,0 mg/l Fe 2,5 mg/l Fe Description: O-phenanthroline, 2 reagents 5,0 mg/l Fe 10,0 mg/l Fe Iron HR Hinged lid box Iron HR NA Refill package Iron HRS (0,2 10 mg/l Fe) Number of analyses: 150 Colour 0,2 mg/l Fe 0,5 mg/l Fe Duration of analysis: 3 min values: 1,0 mg/l Fe 2,5 mg/l Fe Description: O-phenanthroline, 1 reagent 5,0 mg/l Fe 10,0 mg/l Fe Iron HRS Hinged lid box Iron HRS NA Refill package Safety reliably produced. 24

25 Test kits for water analysis based on colorimetric method Manganese (0,03 1,0 mg/l Mn) Number of analyses: 100 Colour 0,03 mg/l Mn 0,05 mg/l Mn Duration of analysis: 10 min value: 0,1 mg/l Mn 0,25 mg/l Mn Description: Formaldoxime, 0,5 mg/l Mn 1,0 mg/l Mn 3 reagents Mangan Hinged lid box Mangan NA Refill package Nitrate (1 50 mg/l NO3 - ) Number of analyses: 200 Colour 1 mg/l NO3-10 mg/l NO3- Duration of analysis: 6 min value: 20 mg/l NO3-30 mg/l NO3- Description: NED, 2 reagents 40 mg/l NO3-50 mg/l NO3- Nitrate Hinged lid box Nitrate NA Refill package ph 2-5 (2 5 ph) Number of analyses: 300 Colour ph 2,0 Duration of analysis: 1 min value: ph 3,5 Description: Mixed reagent, 1 reagent ph 4,5 ph Hinged lid box ph 2-5 NA Refill package ph 3,0 ph 4,0 ph 5,0 ph 5-8 (5 8 ph) Number of analyses: 300 Colour ph 5,0 Duration of analysis: 1 min value: ph 6,5 Description: Mixed reagent, 1 reagent ph 7,5 ph Hinged lid box ph 5-8 NA Refill package ph 6,0 ph 7,0 ph 8,0 ph 8-12 (8 12 ph) Number of analyses: 300 Colour ph 8,0 Duration of analysis: 1 min value: ph 9,0 Description: Mixed reagent, 1 reagent ph 11,0 ph Hinged lid box ph 8-12 NA Refill package ph 8,5 ph 10,0 ph 12,0 25

26 Test kits for water analysis based on colorimetric method ph- Chlorine (free) Number of analyses: 50 Duration of analysis: 1 min Description: DPD / phenolred, 1 reagent / 2 reagents Colour value: 6,8-7,4-8,0 ph Number of analyses: 50 Colour 0,1-0,5-1,0 mg/l Cl2 Duration of analysis: 1 min value: Description: 1 reagent (ph bath), 2 reagents (chlorine A + B) ph-chlorine (free) Hinged lid box ph-chlorine (free) NA Refill package (3 reagents) ph-chlorine Refill package (1 reagent) ph-bath NA ph-chlorine Chlorine A+B NA Refill package (reagents A + B) Phosphate LR (0,25 10 mg/l PO4 3- ) Number of analyses: 200 Colour 0,25 mg/l PO4 3-0,5 mg/l PO4 3- Duration of analysis: 5 min value: 1,0 mg/l PO4 3-2,5 mg/l PO4 3- Description: Molybdate, 2 reagents 5,0 mg/l PO4 3-10,0 mg/l PO4 3- Phosphate LR Hinged lid box Phosphate LR NA Refill package Phosphate HR (2,5 100 mg/l PO4 3- ) Number of analyses: 100 Colour 2,5 mg/l PO4 3-5,0 mg/l PO4 3- Duration of analysis: 5 min value: 10,0 mg/l PO4 3-25,0 mg/l PO4 3- Description: Molybdate, vanadate, 1 reagent 50,0 mg/l PO ,0 mg/l PO4 3- Phosphate HR Hinged lid box Phosphate HR NA Refill package Silicate (0,25 10 mg/l SiO2) Number of analyses: 100 Colour 0,25 mg/l SiO2 0,5 mg/l SiO2 Duration of analysis: 8 min value: 1,0 mg/l SiO2 2,5 mg/l SiO2 Description: Molybdate, 3 reagents 5,0 mg/l SiO2 10,0 mg/l SiO2 Silicate Hinged lid box Silicate NA Refill package Safety reliably produced. 26

27 Test kits for water analysis based on colorimetric method Sulfide (0,05 1,0 mg/l S 2- ) Number of analyses: 100 Colour 0,05 mg/l S 2-0,1 mg/l S 2- Duration of analysis: 7 min value: 0,25 mg/l S 2-0,5 mg/l S 2- Description: DPD, 2 reagents 0,75 mg/l S 2-1,0 mg/l S 2- Sulfide Hinged lid box Sulfide NA Refill package Sulfite (0,5 20 mg/l SO3 2- ) Number of analyses: 150 Colour 0,5 mg/l SO3 2-1,0 mg/l SO3 2- Duration of analysis: 3 min value: 2,5 mg/l SO3 2-5,0 mg/l SO3 2- Description: Thiobenzoeacid, 2 reagents 10,0 mg/l SO3 2-20,0 mg/l SO3 2- Sulfite Hinged lid box Sulfite NA Refill package 27

28

29 How to order from us: RLS Wacon GmbH Eduard-Ahlborn-Str Hildesheim Germany by phone: by info@rls-wacon.de using the enclosed form by Fax: by mail: RLS Wacon GmbH Eduard-Ahlborn-Str Hildesheim Germany MY ORDER Customer (ID): I hereby order the following articles: Article name Article No. Quantity Price Date / signature and company stamp

30

31 Imprint: RLS Wacon GmbH Eduard-Ahlborn-Str. 1 D Hildesheim Phone: +49 (0) 5121 / Fax: +49 (0) 5121 / info@rls-wacon.de Managing Director: Dr. Claudia Rudolph, Dr. Sascha Matern Register court: District Court of Hildesheim Registration no.: HRB VAT ID: DE Picture on the front and back: Vitali Vidnevski (employee of RLS Wacon GmbH), 2015 Subject to modifications and errors Safety reliably produced.

32 Safety reliably produced.

Photometer AL250. Scroll Memory (SM) N.I.S.T Traceability. Highlights

Photometer AL250. Scroll Memory (SM) N.I.S.T Traceability. Highlights Photometer AL250 10 The AL250 models each offer one test method, while the AL250+ units are programmed for a number of different parameters. The units supply accurate, reproducible results very quickly.

More information

Reagents for Chemical Test Kits

Reagents for Chemical Test Kits for Chemical Test Kits Acidity, methyl orange method ; 0 to 500 mg/l HI 3820-100 Reagent kit for 110 tests (CaCO 3 ) Acidity, olive oil, titration with hydroxide 0.00 to 1.00% HI 3897 Reagent kit for 6

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

Water Analysis VISOCOLOR VISOCOLOR. Water analysis made easy. VISOCOLOR tests for water analysis

Water Analysis VISOCOLOR VISOCOLOR. Water analysis made easy. VISOCOLOR tests for water analysis Water Analysis VISOCOLOR VISOCOLOR Water analysis made easy VISOCOLOR tests for water analysis Various measuring methods and detection principles for many parameters Visual and photometric determination

More information

Process Instrumentation analyzers

Process Instrumentation analyzers PCA300 Family Chlorine, ph, ORP and Temperature Analyzers Backlit LCD display Nema 4X protection.10 DPD chlorine measurement method Colorimeter diagnostics Reagent reminder Amplified ph/temperature probe

More information

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed

More information

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Oxidising agents such as chlorine or anorganic

More information

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer Temperature Control without Compromise: rapid changes, precise temperatures, powerful complex functionality.

More information

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX LANCER reserves the right to modify, constantly its documentation for its improvement. The values of adjustments indicated in the displays of this manual are

More information

Edgetech Instruments Inc.

Edgetech Instruments Inc. 2015_07_ETI OVERVIEW Rev 3 MADE IN THE USA Edgetech Instruments (ETI) is a USA company based in Massachusetts. We have over 50 years of expertise in the design and manufacture of a comprehensive range

More information

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting.

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting. Chlorine, Total DOC316.53.01497 USEPA DPD Method 1 Method 10260 0.04 to 10.00 mg/l as Cl 2 Chemkey Reagents Scope and application: For drinking water. This product has not been evaluated to test for chlorine

More information

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Oxidising agents such as chlorine or anorganic

More information

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 Fast Response - Low Maintenance DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand- Held Dewpoint Meter DM70 offers accurate

More information

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology Clean Water through Innovative Technology NEW!! Instrument Overview Reliable Chlorine Monitoring HF scientific developed the OnLine Residual Chlorine Monitor specifically for drinking water, wastewater

More information

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F Similar Image Rugged, powerful turbopump with a pumping speed of up to

More information

FC80 Free Chlorine Analyzer ELECTRO-CHEMICAL DEVICES

FC80 Free Chlorine Analyzer ELECTRO-CHEMICAL DEVICES FC80 Free Chlorine Analyzer ELECTRO-CHEMICAL DEVICES FC80 System Configuration Free Chlorine Analyzer 1) Constant Head Flow Controller 2) S80- ph with Temperature Sensor 3) Free Chlorine Sensor (FCS) 4)

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

Phosphate total LR TT mg/l P b) Phosphomolybdenum Blue

Phosphate total LR TT mg/l P b) Phosphomolybdenum Blue Phosphate total LR TT 0.07-3 mg/l P b) Phosphomolybdenum Blue 317 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption

More information

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed

More information

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser The latest innovation in total Suspended Particulate Matter (SPM) measurement The Measure of Technology Made in Germany TÜV CERTIFIED

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM IC Application Work AW CH6-1048-012011 Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM Branch: Chemical industry; Water, wastewater, environmental protection,

More information

Application Your benefits

Application Your benefits Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 flow assembly Application Oxidizing agents such as chlorine or anorganic

More information

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen INSTRUCTION MANUAL FA 510 The CS dew point sensor FA 510 with 3-wire technology 4 20 ma and RS 485 output enables a reliable and long-term stable monitoring of the dew point in industrial applications

More information

Wöhler DP 700 Leakage Tester

Wöhler DP 700 Leakage Tester LEAKAGE CLASS ACHIEVED? Wöhler DP 700 Leakage Tester The Measure of Technology Made in Germany COLOR DISPLAY EINFACHE BEDIENUNG Wöhler DP 700 Leakage Tester Just 3 entries to classify an air ductwork system

More information

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability DM70 Hand-held Dewpoint Meter Truly Fast Response - Superior Long-term Stability DM70 - When Dry Air Is Important The Vaisala DM70 Hand-held Dewpoint Meter offers stable and fast measurement for industrial

More information

Kjeltec 2300 Analyzer Unit

Kjeltec 2300 Analyzer Unit Kjeltec 2300 Analyzer Unit Automatic distillation and approved colorimetric titration for analysis of Kjeldahl nitrogen/protein, ammonium- nitrogen, TKN, Direct distillation (DD), volatile acids/ bases

More information

ISEmax CAS40D. Technical Information

ISEmax CAS40D. Technical Information Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor

More information

Parameter Method Range # of Tests Code Page. Acidity (as % Oleic acid) titration % acidity 6 HI

Parameter Method Range # of Tests Code Page. Acidity (as % Oleic acid) titration % acidity 6 HI Single Parameter Test Kits Parameter # of Tests Code Page Acidity Acidity (as % Oleic acid) 0.00-1.00 % acidity 6 HI387.8 Acidity (as CaCO₃) Methyl/Orange and Total 0-100 mg/l (ppm); 0-500 mg/l (ppm) 110

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Silicate LR VARIO PP 0.05 -.6 mg/l SiO 2 Heteropolyblue 35 SiLr Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption

More information

Phosphate total HR TT mg/l P b) Phosphomolybdenum Blue

Phosphate total HR TT mg/l P b) Phosphomolybdenum Blue Phosphate total HR TT 1.5-20 mg/l P b) Phosphomolybdenum Blue 318 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption

More information

Automatic titrators, TitroMatic

Automatic titrators, TitroMatic 112 TitroMatic These are the fourth generation of CRISON titrators. CRISON has over 25 years experience in this field and knows that, for certain applications, the performance and cost of large titrator

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities instruments 5 YEARS G U A R A N T E E Quality at a reasonable price The optimum combination

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully

More information

SC400 Colorimeter. Silica. Photometer-System. Instruction Manual. SiO 2. Bedienungsanleitung Seite Instruction Manual Page 19 33

SC400 Colorimeter. Silica. Photometer-System. Instruction Manual. SiO 2. Bedienungsanleitung Seite Instruction Manual Page 19 33 Photometer-System SC400 Colorimeter SiO 2 Silica DE GB FR IT ES Bedienungsanleitung Seite 3 17 Instruction Manual Page 19 33 d'emploi Page 35 49 Instruction Manual Istruzioni d'uso Pagina 51 65 Instrucciones

More information

GS4000 DATASHEET JUNHO 2013

GS4000 DATASHEET JUNHO 2013 GS4000 DATASHEET JUNHO 2013 www.severntrentservices.com Biochem T70GS4000 Chlorine Dioxide Generator - 2g/day - 10g/h System Advantages Dosage Flexibility The generator produces a chlorine dioxide solution,

More information

HiPace 300 with TC 110, DN 100 CF-F

HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F Rugged, powerful turbopump with a pumping speed of up to 260 l/s for N 2 Integrated TC 110 drive electronics Ideal for UHV applications

More information

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 5000 DR The fill line is to the right.

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 5000 DR The fill line is to the right. Barium DOC316.53.01315 Turbidimetric Method 1 Method 10251 2 to 100, 20 to 1000, 200 to 10,000 mg/l Ba (spectrophotometers) Powder Pillows 2 to 80, 20 to 800, 200 to 8000 mg/l Ba (colorimeters) Scope and

More information

RIMA OFFICIAL CATALOGUE CATALOGUE TP

RIMA OFFICIAL CATALOGUE CATALOGUE TP RAIL BRAKES RIMA OFFICIAL CATALOGUE UE 1 / 1 4 FEBRUARY 2013 CATALOGUE TP UE 2 / 1 4 DescriPt Ption Utilization and functioning Rail brakes, suitable for medium forces from 20 to 300 kn (securing cranes

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Deionized Water. Latest technology, highest quality, environmentally friendly. Water Technologies

Deionized Water. Latest technology, highest quality, environmentally friendly. Water Technologies Deionized Water Latest technology, highest quality, environmentally friendly Water Technologies NaCl OH - Cl - OH - OH - Cl - Anion OH - OH - Resin OH - OH OH - - OH - OH - Na + Na + Cation Resin H + H

More information

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of

More information

Vet Photometer DP 700 Operating Manual. Version V5.9

Vet Photometer DP 700 Operating Manual. Version V5.9 1 Vet Photometer DP 700 Operating Manual Version V5.9 2 Dear customer, Thank you for selecting Diaglobal s Vet Photometer and for the confidence you have placed in us. The Vet Photometer belongs to a new

More information

Flushing Out the Moles in Lab: The Reaction of Calcium Chloride with Carbonate Salts

Flushing Out the Moles in Lab: The Reaction of Calcium Chloride with Carbonate Salts Flushing Out the Moles in Lab: The Reaction of Calcium Chloride with Carbonate Salts Pre-lab Assignment: Reading: 1. Chapter sections 3.3, 3.4, 3.7 and 4.2 in your course text. 2. This lab handout. Questions:

More information

ION CHROMATOGRAPHY SYSTEM S 150

ION CHROMATOGRAPHY SYSTEM S 150 ION CHROMATOGRAPHY SYSTEM S 150 WATER ANALYSIS ENVIRONMENTAL ANALYSIS ANION & CATION ANALYSIS ION CHROMATOGRAPHY IIon Chromatography is an analytical separation technique based on ionic interactions. Dissolved

More information

MRI Flocculation. MRI Flocculation Systems. Mix & Match for Maximum Pretreatment Control

MRI Flocculation. MRI Flocculation Systems. Mix & Match for Maximum Pretreatment Control MRI Flocculation MRI Flocculation Systems Mix & Match for Maximum Pretreatment Control MRI Flocculation P resenting MRI m a n u f a c t u r e s v e r t i c a l t u r b i n e s (s h o w n ), h o r i z o

More information

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832 , TNTplus 832, 10205 DOC316.53.01083 Salicylate Method Method 10205 HR (2 to 47 mg/l NH 3 N) TNTplus 832 Scope and Application: For surface waters, municipal and industrial wastewaters. Test preparation

More information

ADI 2040 Process Analyzer

ADI 2040 Process Analyzer ADI 2040 Process Analyzer Multi-purpose wet chemical analysis Multi-purpose Wet Chemical Analysis ADI 2040 The Metrohm Applikon ADI 2040 Process Analyzer is a multipurpose wet chemical analyzer, that has

More information

Chematest 25. Operator s Manual A Swan Analytical Instruments AG CH-8340 Hinwil/Switzerland ANALYTICAL INSTRUMENTS

Chematest 25. Operator s Manual A Swan Analytical Instruments AG CH-8340 Hinwil/Switzerland ANALYTICAL INSTRUMENTS Chematest 25 Operator s Manual A70.065.611 ANALYTICAL INSTRUMENTS Swan Analytical Instruments AG CH-8340 Hinwil/Switzerland Table of Contents Photometry 1.1 Basic Rules for Photometric Determinations 5

More information

CHINA MP FILTRI P.O. Box Shanghai Phone: Fax:

CHINA MP FILTRI P.O. Box Shanghai Phone: Fax: FMP 038 uk 6-07-006 9:34 Pagina (,) New Headquarters : MP FILTRI S.p.A. Italy Via Maggio, n. 3 0060 Pessano con Bornago (Milano) Italy Tel. +39.0/95703. Fax +39.0/9574497-9574088 email: sales@mpfiltri.com

More information

Nanotechnology Sensors

Nanotechnology Sensors ESILAB PACK : 1 Ion + ph Nanotechnology Sensors email : contact@water-kits.fr This revolutionary technology based on carbon nanotubes hugely simplifies the potentiometric measurements. Measurement & calibration

More information

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows FILL LINE Method 8155 Salicylate Method 1 Powder Pillows Scope and Application: For water, wastewater, and seawater 1 Adapted from Clin. Chim. Acta., 14, 403 (1966) (0.01 to 0.50 mg/l NH 3 N) Test Preparation

More information

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015 Ion Selective Electrodes for the Laboratory Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015 Outline Review ISE measurement technology How to properly calibrate

More information

CHLORINE THEORY & MEASUREMENT

CHLORINE THEORY & MEASUREMENT CHLORINE THEORY & MEASUREMENT Introduction Chlorine, dissolved in liquid, is one of the most effective and economical germ-killers for the treatment of water to make it potable or safe to drink. Chlorine's

More information

McQuay Climate Control Singer

McQuay Climate Control Singer Replacement Parts List No. 055204800 Revision B 01/2017 McQuay Climate Control Singer Vertical Water Source Heat Pump FC, FG, FW 240, 330, 400, 500 Vintages C, D Last Manufactured: 1986 To find your Daikin

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219 REX Evaluation Guide American Micro Detection Systems Inc. 2800 March Lane, Suite 200 Stockton, CA 95219 I. INTRODUCTION REX (Real-time Elemental X-ray Fluorescence System) is the only instrument capable

More information

Phosphate HR T 1-80 mg/l P Vanadomolybdate

Phosphate HR T 1-80 mg/l P Vanadomolybdate Phosphate HR T 1-80 mg/l P Vanadomolybdate 321 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion

More information

Method (0.04 to 4.50 mg/l Cl 2 ) Powder Pillows

Method (0.04 to 4.50 mg/l Cl 2 ) Powder Pillows Chlorine Free, Indophenol, 10241 Indophenol 1 1 Patent pending. DOC316.53.01256 Method 10241 (0.04 to 4.50 mg/l Cl 2 ) Powder Pillows Scope and Application: For determining residual free chlorine levels

More information

General Chemistry. Contents. Chapter 5: Introduction to Reactions in Aqueous Solutions. Electrolytes. 5.1 The Nature of Aqueous Solutions

General Chemistry. Contents. Chapter 5: Introduction to Reactions in Aqueous Solutions. Electrolytes. 5.1 The Nature of Aqueous Solutions General Chemistry Principles and Modern Applications Petrucci Harwood Herring 8 th Edition Chapter 5: Introduction to Reactions in Aqueous Solutions Philip Dutton University of Windsor, Canada N9B 3P4

More information

Ion-Chamber Survey Meter OD-02

Ion-Chamber Survey Meter OD-02 Ion-Chamber Survey Meter OD-02 Dose and dose rate meter for measuring the ambient dose equivalent H*(10) and dose rate equivalent dh*(10)/dt as well as the directional dose equivalent H (0,07) and dose

More information

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

Display counter electromechanical

Display counter electromechanical Micro Display counter K 04... K 07, shock resistant 4-, 5-, 6- and 7 digit Micro adding counter High shock resistance Low power consumption; suitable for battery consumption small dimensions Large optical

More information

General Chemistry. Chapter 5: Introduction to Reactions in Aqueous Solutions. Principles and Modern Applications Petrucci Harwood Herring 8 th Edition

General Chemistry. Chapter 5: Introduction to Reactions in Aqueous Solutions. Principles and Modern Applications Petrucci Harwood Herring 8 th Edition General Chemistry Principles and Modern Applications Petrucci Harwood Herring 8 th Edition Chapter 5: Introduction to Reactions in Aqueous Solutions Philip Dutton University of Windsor, Canada N9B 3P4

More information

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER Technical Description Version 2 BGRIMM AUTOMATION, South 4th Ring Road West, Beijing, China TEL: +86(10)59069762 Fax: +86(10)68360101 Contents BGRIMM AUTOMATION

More information

387 Low & Medium Pressure filters

387 Low & Medium Pressure filters Low & Medium Pressure fi lters LMD 000 & series Maximum pressure up to 6 bar Flow rate up to 90 l/min 87 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3 / - / SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 99/ sizes, and Series Fluids air or inert gas, filtered, lubricated or not Operating pressure Pilot pressure Ambient

More information

HiPace 300 with TC 400, DN 100 CF-F

HiPace 300 with TC 400, DN 100 CF-F HiPace 300 with TC 400, DN 100 CF-F HiPace 300 with TC 400, DN 100 CF-F Similar Image Rugged, powerful turbopump with a pumping speed of up to 260 l/s for N 2 Integrated TC 400 drive electronics Ideal

More information

R-Biopharm AG RIDA CUBE SCAN. The smart analyser. Product Information. R-Biopharm for the safety of your analysis.

R-Biopharm AG RIDA CUBE SCAN. The smart analyser. Product Information. R-Biopharm for the safety of your analysis. R-Biopharm AG The smart analyser Product Information R-Biopharm for the safety of your analysis. Intended use The R-Biopharm is a new photometric system that allows biochemistry testing in small food laboratories

More information

Chromazurol S Method Method to 0.50 mg/l Al TNTplus 848

Chromazurol S Method Method to 0.50 mg/l Al TNTplus 848 Aluminum DOC316.53.01004 Chromazurol S Method Method 10215 0.02 to 0.50 mg/l Al TNTplus 848 Scope and application: For drinking water, surface water, swimming pool water, wastewater and process analysis.

More information

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual Coating Thickness Gauge art. nr. 59252 Table of contents 1. Technical specifications...3 2. Getting started...3 3. Gauge manual...6 The price of this product includes the recycling fee of 0,10 PLN Guarantee...11

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

CTC 155 / 350 / 660 Dry-block calibrator

CTC 155 / 350 / 660 Dry-block calibrator CTC 155 / 350 / 660 Dry-block calibrator Wide temperature range: CTC-155: -25 to 155 C CTC-350: 28 to 350 C CTC-660: 28 to 660 C Fast calibration External reference sensor External sensor control Easy

More information

University Wet Chemistry Analyzer Packages

University Wet Chemistry Analyzer Packages University Wet Chemistry Analyzer Packages University laboratories and public research institutions have a special place in the scientific community. Often they are tasked with undertaking basic research

More information

PAA-ANALYZERS PRINCIPLE OF OPERATION

PAA-ANALYZERS PRINCIPLE OF OPERATION PAA-ANALYZERS PRINCIPLE OF OPERATION The PAA process analyzer comprises a control unit and an analyzing section which includes the reaction chamber and measuring cell, reagent pumps and associated valves

More information

Frequently asked question about our new Platinum Water Ionizer

Frequently asked question about our new Platinum Water Ionizer Frequently asked question about our new Platinum Water Ionizer How many electrodes does the Platinum Water Ionizer have? Answer: 2, One positive and One negative How many electrolysis plates does the Platinum

More information

Stamolys CA71HA. Technical Information

Stamolys CA71HA. Technical Information Technical Information Stamolys CAHA Total Hardness Analyzer Compact photometric analysis system for total hardness measurement in drinking water systems Application Total hardness monitoring in reverse

More information

Thermal Mass Flow Meter for Gases

Thermal Mass Flow Meter for Gases Thermal Mass Flow Meter for Gases measuring monitoring analysing Direct mass flow rate measurement of gases Measuring accuracy: ±1.0% f.s. +0.5% m.v. pmax PN 16, tmax 175 C Fast response time No moving

More information

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. Flow sensors www.ifm.com/mid Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. For industrial applications Volumetric flow sensor efector mid. High-precision

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Chlorine L a) 0.02-4.0 mg/l Cl 2 DPD 101 CL6 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer

More information

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856 Nickel DOC316.53.01065 Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows

More information

Development of an organometallic flow chemistry. reaction at pilot plant scale for the manufacture of

Development of an organometallic flow chemistry. reaction at pilot plant scale for the manufacture of Supporting Information Development of an organometallic flow chemistry reaction at pilot plant scale for the manufacture of verubecestat David A. Thaisrivongs*, John R. Naber*, Nicholas J. Rogus, and Glenn

More information

Chemistry CH3FP Unit Chemistry C3 Written Paper Monday 20 May pm to 2.30 pm For this paper you must have: Time allowed Instructions all

Chemistry CH3FP Unit Chemistry C3 Written Paper Monday 20 May pm to 2.30 pm For this paper you must have: Time allowed Instructions all Centre Number Surname Candidate Number For Examiner s Use Other Names Candidate Signature Examiner s Initials Question Mark General Certificate of Secondary Education Foundation Tier June 2013 1 2 Chemistry

More information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems

More information

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz LABOTRON EXTRACTION & SYNTHESIS 2450 MHz The LABOTRON TM series is the generic name for a ground breaking range of integrated reactor and microwave transmission systems especially designed to carry out

More information

Nitrogen, Total Inorganic

Nitrogen, Total Inorganic Nitrogen, Total Inorganic DOC316.53.01090 Titanium Trichloride Reduction Method Method 10021 0.2 to 25.0 mg/l N Test N Tube Vials Scope and application: For water, wastewater and seawater. Test preparation

More information

FVBSS fixed volume bottle

FVBSS fixed volume bottle N FVBSS fixed volume bottle Sampling System The SENSOR Fixed Volume Bottle Sampling System (FVBSS) provides a repeatable fixed volume of sample during each sampling process without stopping flow of the

More information

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically Complete Set ph PRO Controller - 1 pcs. ph electrode - 1 pcs. Calibration

More information

2-way proportional throttle valve for block installation

2-way proportional throttle valve for block installation -way proportional throttle valve for block installation Types FES; FESE Sizes to Component series X Maximum operating pressure bar Maximum flow 800 l/min at Δp = 0 bar Table of contents Contents Page Features

More information

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012 Replacement Parts List No. 055231000 Revision C 04/2012 Singer Incremental Comfort Systems K, EK 07-15 Vintage F Last Manufactured: 1976 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

CHEMICAL REACTORS TEACHING EQUIPMENT CEXC

CHEMICAL REACTORS TEACHING EQUIPMENT CEXC CE SERIES: BASIC PROCESS PRINCIPLES CHEMICAL REACTORS TEACHING EQUIPMENT CEXC NOW COMPUTER CONTROLLED AS STANDARD 3 NEW REACTORS AVAILABLE CEXC service unit shown fitted with CEB-MkIII transparent batch

More information

HiPace 1200, with TC 1200, DN 200 CF-F

HiPace 1200, with TC 1200, DN 200 CF-F HiPace 1200, with TC 1200, DN 200 CF-F HiPace 1200, with TC 1200, DN 200 CF-F Similar Image Powerful turbopump with a pumping speed of up to 1250 l/s for N 2 DN 200 CF-F flange for demanding UHV applications

More information

SPECIFICATION SHEET : FHS2-UNV-36L

SPECIFICATION SHEET : FHS2-UNV-36L SPECIFICATION SHEET : FHS2-UNV-36L This Is An Original Product From Fulham Co., Inc Description : For Back-up Lighting This driver will operate constant current LED arrays with a working voltage between

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Nitrogen total HR VARIO TT 5-150 mg/l N b) 81 Persulphate Digestion Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption

More information

Phenolphthalein and Total Alkalinity Method to 4000 mg/l as CaCO 3 Digital Titrator

Phenolphthalein and Total Alkalinity Method to 4000 mg/l as CaCO 3 Digital Titrator Alkalinity DOC316.53.01166 Phenolphthalein and Total Alkalinity Method 8203 10 to 4000 mg/l as CaCO 3 Digital Titrator Scope and application: For water, wastewater and seawater. Test preparation Before

More information