Weather Station P03/3-RS485 with RS485 Interface
|
|
- Norma Hampton
- 6 years ago
- Views:
Transcription
1 Weather Station P03/3-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D Gechingen Germany Phone: +49 (0) 70 56/ Fax: +49 (0) 70 56/ info@elsner-elektronik.de
2 Description The P03/3-RS485 Weather Station measures temperature, wind speed and brightness (eastern, sothern and western sun). It recognizes precipitation and receives the DCF77 radio signal for date and time. The weather station sends the currently recorded weather data, date and time once every second. This data flow can be received and analyzed by an end device such as SPS, PC or MC. If the DCF signal cannot be received, the data is output approx. every 1.35 seconds. The P03/3-RS485 has four connections. Data output is at terminals A and B. Terminals 1 and 2 are for the power supply (24 V DC). The connections are not resistant to pole reversal. Connecting them incorrectly will destroy the interface components. Functions: Brightness measurement with three separate sensors for east, south and west. Recognition of twilight/dawn with special filters Wind speed measurement by means of a nonwearing electronic sensor. No damage from storm or hail as with mechanical anemometers Temperature measurement Heated precipitation sensor (1.2 watts): No false reports as a result of fog or dew. Dries quickly after precipitation has stopped Integrated DCF77 radio clock receiver Technical data Housing: Colour: Mounting: Plastic material White / translucent On-wall Protection category: IP 44 Dimensions: Weight: Ambient temperature: Operating voltage: approx. 96 x 77 x 118 (W x H x D, mm) approx. 160 g Operation C, Storage C 24 V DC Current: max. 105 ma, residual ripple 10% If switching power supply units are applied, the quality of the radio clock reception may be influenced. Data output: Heating rain sensor: RS485 approx. 1.2 W 2 Weather Station P03/3-RS485 Version: 30 September2009 Subject to technical alterations. Errors excepted.
3 Measurement range temperature: Measurement range wind: Measurement range brightness: C Resolution: 0.1 C Accuracy: ±0.5 C at C ±1.5 C at C 0 70 m/s Resolution: <10% of the measured value Accuracy: ± 25% at 0 15 m/s, at an angle of attack of 45, pole mounting lux Resolution: 1 lux at lux 2 lux at lux 63 lux at lux 423 lux at lux Accuracy: ± 35% The following standards were referenced with regard to evaluating electromagnetic compatibility of the product: EN : A11:2002 The product has been tested by an accredited EMC laboratory according to the abovementioned standards. Weather Station P03/3-RS485 Version: 30 September2009 Subject to technical alterations. Errors excepted. 3
4 PCB layout Fig. 1 1 Socket for connecting cables to rain sensor in housing cover 2 Socket for connection 1: +24 V DC 2: GND A: Data B: Data 3 DCF77 reception control LED 4 DCF77 antenna set screw 4 Weather Station P03/3-RS485 Version: 30 September2009 Subject to technical alterations. Errors excepted.
5 Transfer protocol All characters and/or digits are based on the ASCII standard, i.e. every reading processed internally as an integer or float value will always be broken down into and transferred in its individual ASCII format characters. They must then be reassembled in the reverse process by the receiver. Transfer rate: Baud Data bits: 8 Stop bit: 1 Parity: none The checksum is calculated along by the receiver by adding all received bytes up until byte 35 and then compared with the checksum transferred from the P03. Units: Temperatures in degrees Celsius Sun intensity in kilolux Daylight in Lux Wind in metres per second The DCF signal can be easily interfered with. It is possible for no radio clock reception to exist for extended periods. Therefore, only use the output time for synchronization of another clock working in parallel in the system. For this, the second 0 should be used. Byte No. Char Meaning 1 W Weather data start 2 OT: Sign Outdoor temperature sign / + 3 OT: 1st digit Outdoor temperature 1st digit (tens) 4 OT: 2nd digit Outdoor temperature 2nd digit (ones) 5 OT: Point Outdoor temperature point 6 OT: 3rd digit Outdoor temperature 3rd digit (tenth) 7 SuS: 1st digit Sun South 1st digit (tens) 8 SuS: 2nd digit Sun South 2nd digit (ones) 9 SuW: 1st digit Sun West 1st digit (tens) 10 SuW: 2nd digit Sun West 2nd digit (ones) 11 SuE: 1st digit Sun East 1st digit (tens) 12 SuE: 2nd digit Sun East 2nd digit (ones) 13 Twilight Twilight: J = Yes; N = No 14 Daylight 0-999Lx Daylight (1st digit hundreds) 15 Daylight 0-999Lx Daylight (2nd digit tens) 16 Daylight 0-999Lx Daylight (3rd digit ones) 17 Wind: 1st digit Wind 1st digit (tens) 18 Wind: 2nd digit Wind 2nd digit (ones) 19 Wind: Point Wind Point 20 Wind: 3rd digit Wind 3rd digit (tenth) Weather Station P03/3-RS485 Version: 30 September2009 Subject to technical alterations. Errors excepted. 5
6 Byte No. Char Meaning 21 Rain Rain: J = Yes; N = No 22 Weekday: 1-7 Weekday: 1 = Mo, 7 = Su 23 Date: Day 1st digit Date: Day 1st digit (tens) 24 Date: Day 2nd digit Date: Day 2nd digit (ones) 25 Date: Month 1st digit Date: Month 1st digit (tens) 26 Date: Month 2nd digit Date: Month 2nd digit (ones) 27 Date: Year 1st digit Date: Year 1st digit (tens) 28 Date: Year 2nd digit Date: Year 2nd digit (ones) 29 Time: Hrs. 1st digit Time: Hrs. 1st digit (tens) 30 Time: Hrs. 2nd digit Time: Hrs. 2nd digit (ones) 31 Time: Min. 1st digit Time: Min. 1st digit (tens) 32 Time: Min. 2nd digit Time: Min. 2nd digit (ones) 33 Time: Sec. 1st digit Time: Sec. 1st digit (tens) 34 Time: Sec. 2nd digit Time: Sec. 2nd digit (ones) 35 Summertime J = Summertime N = Wintertime? = Not defined 36 Checksum: 1st digit Checksum 1st digit (thousands) 37 Checksum: 2nd digit Checksum 2nd digit (hundreds) 38 Checksum: 3rd digit Checksum 3rd digit (tens) 39 Checksum: 4th digit Checksum 4th digit (ones) 40 End End 0x03 Installation and first use The weather station may only be installed, tested, put into operation and troubleshot by a person qualified to do so. When connecting the weather station, do not connect any live wires (switch off the mains fuse first) and take precautionary measures to prevent them from being accidentally switched back on. Make sure all connections are correct. An incorrect connection could destroy the weather station or any electronic devices connected to it. The weather station must be used for its intended purpose only. Any improper modification or failure to observe the operation instructions will void all guarantees or claims to warranty. When unpacking, check the unit immediately for any mechanical damage. The supplier must be informed immediately of any damage caused during transport. The weather station must not be put into use if damaged. If there is any cause to believe that safe operation is no longer guaranteed, the system must be rendered inoperative and secured against being switched on unintentionally. 6 Weather Station P03/3-RS485 Version: 30 September2009 Subject to technical alterations. Errors excepted.
7 The weather station may only be operated as a stationary installation; i.e. only when mounted and after all installation and initialization procedures are complete, and only in the environment it is intended for. Elsner Elektronik is not liable for any changes to standards or defaults after publication of the operation instructions. Position Choose an installation position in the building where wind, rain and sun can be measured unhindered by the sensors. The weather station must not be installed underneath any structural parts from which water can still drip onto the rain sensor after it has stopped raining or snowing. The weather station must not be shaded by anything, such as building structures or trees. There must be at least 60 cm of free space underneath the weather station to allow it to measure the wind correctly and to prevent it from being snowed in when it snows. Iron structures or large-surfaces of sheet metal directly behind or near the weather station reduce the reception quality of the integrated radio clock receiver. Please take this into account when choosing the installation site. Also, magnetic fields, transmitters and interfering fields from electricity consumers (e.g. fluorescent lamps, neon signs, switched-mode power supplies etc.) can interfere with or even cut out reception of the DCF signal. North Fig. 2 Align the weather station in a southward direction. South Fig. 3 The weather station must be mounted onto a vertical wall (or pole). Weather Station P03/3-RS485 Version: 30 September2009 Subject to technical alterations. Errors excepted. 7
8 Fig. 4 The weather station must be mounted horizontally in the lateral direction. Attaching the mount The weather station comes with a combination wall/pole mount. The mount comes adhered by adhesive strips to the rear side of the housing. Fasten the mount vertically onto the wall or pole. Fig. 5 When wall mounting: flat side on wall, crescentshaped collar upward. Fig. 6 When pole mounting: curved side on pole, collar downward. Fig. 7 An additional, optional accessory available from Elsner Elektronik is an articulated arm for flexible wall, pole or beam mounting of the weather station. 8 Weather Station P03/3-RS485 Version: 30 September2009 Subject to technical alterations. Errors excepted.
9 View of rear side and drill hole plan Fig. 8 a: Dimensions of rear side of housing with bracket. Subject to change for technical enhancement. Fig. 8 b Drill hole plan Weather Station P03/3-RS485 Version: 30 September2009 Subject to technical alterations. Errors excepted. 9
10 Preparing the weather station Fig. 9 The weather station cover with the rain sensor snaps in on the left and right along the bottom edge (see Fig. 9). Remove the weather station cover. Proceed carefully, so as not to pull off the wire connecting the PCB in the bottom part with the rain sensor in the cover (wire with push-connector). Push the connection cable through the rubber seal on the bottom of the weather station and push the power and bus cables onto their designated terminals. The connection is by typical telephone cable (J-Y(ST)Y ). Aligning the DCF77 antenna The antenna for DCF77 reception of date and time is located under the PCB in the housing. Using the set screw (see chapter PCB layout, Fig. 1, No. 4), you can turn the antenna by up to 180 in order to achieve the best alignment. You know you are getting reception when the control LED (see Fig. 1 No. 3) blinks regularly once every second (the blinking stops after 59 seconds). The LED stops blinking 30 minutes after switchingon. 10 Weather Station P03/3-RS485 Version: 30 September2009 Subject to technical alterations. Errors excepted.
11 Mounting the weather station Close the housing by putting the cover back over the bottom part. The cover must snap in on the left and right with a definite click. Fig. 10 Make sure the cover and bottom part are properly snapped together! This picture is looking at the closed weather station from underneath. Fig. 11 Push the housing from above into the fastened mount. The bumps on the mount must snap into the rails in the housing. To remove it, the weather station can be simply pulled upwards out of the mount, against the resistance of the fastening. Notes on installation Do not open the P03 weather station if water (rain) could get in: even a few drops could damage the electronics inside. When mounting, you must take care not to damage the temperature sensor (small PCB on the bottom of the housing). Also, the wire connecting the PCB with the rain sensor must not be pulled off or kinked at the terminal. Remove all existing protection labels after installation. It will take 30 seconds after applying the power before the wind measurement will be output. Weather Station P03/3-RS485 Version: 30 September2009 Subject to technical alterations. Errors excepted. 11
12 Maintenance The weather station must be checked for dirt on a regular, twice-yearly basis and cleaned if necessary. A dirty weather station can lead to strange results, such as the wind sensor failing to work, the station constantly announcing rain, or failure to detect sunlight. 12 Weather Station P03/3-RS485 Version: 30 September2009 Subject to technical alterations. Errors excepted.
Meteorological Station P03/3-RS485-WAGO
Meteorological Station P03/3-RS485-WAGO Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93 97-0
More informationWeather Station P03/3-RS485-GPS with RS485 Interface
Weather Station P03/3-RS485-GPS with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0)
More informationWeather Station P03/3-Modbus-GPS for Modbus
Weather Station P03/3-Modbus-GPS for Modbus Technical specifications and installation instructions Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49
More informationP03/3-RS485-WAGO. Weather Station with RS485 Interface. Technical specifications and installation instructions
EN P03/3-RS485-WAGO Weather Station with RS485 Interface Technical specifications and installation instructions Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone
More informationSuntracer KNX-GPS. Weather Station. Technical specifications and installation instructions Item number 3093
EN Suntracer KNX-GPS Weather Station Technical specifications and installation instructions Item number 3093 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone
More informationOPERATING MANUAL. EIB-Kombisensor AS 315 N
EIB-Kombisensor AS 315 N OPERATING MANUAL EIB-Kombisensor AS 315 N 1 Contents Page 3 1. Description 4 1.1 Automated Operations 1.1.1 Sun System 1.1.2 Half-Light System 5 1.1.3 Wind System 1.1.4 Rain System
More informationiweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved.
iweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved. Table of contents: 1 Introduction...3 2 Station Components...4 3 STATION INSTALLATION PROCEDURE...5 4 Specifications...11
More informationInstruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector
Solar Weather Centre With Wireless Weather Vane Solar Powered Outdoor Weather Data Collector Indoor Receiver Instruction Manual Product Code: WS5056C TECHNICAL DETAILS Thank you for purchasing the Holman
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationWS-9018U Wireless Weather Station. Instruction Manual
WS-9018U Wireless Weather Station Instruction Manual Contents Page 1. Functions of the Weather Station....3 2. Safety notes...3 3. Product features....4 4. Getting started....4 5. Quick Set Up...5 6. Setting
More informationWS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual
WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents 2 Additional Equipment 2 Quick Setup 3 Detailed Setup Guide
More informationAssembly Instructions for the 1-Wire Weather Station V2.0/V3.0
Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0 Tools and Supplies Required (not included): Phillips screwdriver 3/8" wrench Drill with 5/32" bit "U" type mounting bracket (i.e., part number
More informationEIB-Combi-Sensor AS 315 N. Operatingmanual. The right to implement changes is reserved. Rev.03-03/2013 vm. by Somfy GmbH. EIB-Combi-sensor AS 315 N
EIB-Combi-Sensor AS 315 N Operatingmanual Rev.03-03/2013 vm by Somfy GmbH The right to implement changes is reserved. 1 Contents 1 Description...3 1.1 Automated Operations...4 1.1.1 Sun System...4 1.1.2
More informationWhat is the maximum distance I can have the remote sensors from the display?
What is the maximum distance I can have the remote sensors from the display? The maximum open-air distance is 100 meters in a straight line although you should take into account the environment, distance
More informationModel: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started
Model: WT-3181PL Instruction Manual DC: 041614 18 Indoor/Outdoor Atomic Wall Clock Round Battery Cover Get Started Step 1: Remove the round battery cover from the back of the clock. Step 2: Insert 1 fresh
More informationThe Weather Station FEATURES:
WIRELESS 433MHz WEATHER STATION Instructions Manual INTRODUCTION: Congratulations on purchasing this Weather Station with wireless 433MHz transmission of outdoor temperature and display of indoor temperature
More informationCONTENTS. La Crosse Technology, Ltd. Page 1
WS-9133BK-IT- WS-9133T-IT FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader
More informationHD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION
HD2016 [ GB ] Weighing rain gauge Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION [ GB ] HD2016 Weighing rain gauge [ GB ] HD2016 is a rain gauge that detects the weight of the
More informationLED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE
w LED light engine / OLED Module DLE G4 ADV Modules DLE Product description For downlights Luminous flux up to 3,71 lm at tp = 65 C High efficacy up to 185 lm/w for the LED module at tp = 25 C High system
More information- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen
INSTRUCTION MANUAL FA 510 The CS dew point sensor FA 510 with 3-wire technology 4 20 ma and RS 485 output enables a reliable and long-term stable monitoring of the dew point in industrial applications
More informationLED light engines LED compact. Module DLE G4 ADV Modules DLE
w LED light engines Module DLE G4 ADV Modules DLE Product description For downlights Luminous flux up to 6,35 lm at tp = 65 C High efficacy up to 185 lm/w for the LED module at tp = 25 C High system efficacy
More informationPHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 8x0 H ADV D50
w LED light engine / OLED Product description For spotlights and downlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 2,92 lm at tp = 65 C High efficacy up to 147 lm/w
More informationPHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50
w LED light engine / OLED Product description For spotlights and downlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 2,51 lm at tp = 65 C High efficacy up to 124 lm/w
More informationRain Collector (# 7852 & 7852M)
Rain Collector (# 7852 & 7852M) This rain collector can be used with Vantage Pro2 weather stations, including Vantage Pro2, Vantage Pro2 Plus, and the Anemometer/Sensor Transmitter Kit. Note: Model number
More informationLED light engines LED compact. Module SLE G7 ADV Modules SLE ADVANCED
w LED light engines Module SLE G7 ADV Modules SLE ADVANCED Product description For spotlights and downlights For operating with SELV Driver Luminous flux up to 6,18 lm at tp = 65 C High efficacy up to
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationCONTENTS. Batteries. La Crosse Technology, Ltd Page 1
515-1316 FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader CONTENTS
More informationLamp and Control Panel (Lamp Panel)
www.reinhausen.com Lamp and Control Panel (Lamp Panel) Operating Instructions BA 47/0 EN NOTE! Changes may have been made to a product after going to press with this documentation. We expressly reserve
More informationField Pro Operation and Installation Manual
Field Pro Operation and Installation Manual Xtreme Research Corporation SkyScan Division P.O. Box 336, Port Richey, FL 34673-0336 1-800-732-0665 Table of Contents 1. Installation 3 2. Operation 5 3. Care
More informationKingspan Smart-Lite Kite Luminaire
Kingspan Smart-Lite Kite Luminaire The Kite High Bay products are designed to complement the ZEL (Zero Energy Lighting) initiative championed by Kingspan. The combination of pressure die-cast aluminium
More informationB Left-hand case side (x1) F
MD693/ HD-1688 WOODEN RADIO-CONTROLLED GRANDFATHER CLOCK WITH WESTMINSTER CHIMES INSTRUCTIONS PLEASE READ ALL THE INSTRUCTIONS CAREFULLY BEFORE YOU SET YOUR CLOCK GOING AND ENSURE YOU KEEP HOLD OF THESE
More informationPOINTS OF CAUTION BEFORE USE...
INSTRUCTION MANUAL NPN DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 6 points each (-I/-II, e-con connector) MODEL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the
More informationOASIS WIRELESS WEATHER STATION
User Manual 3910-B Royal Avenue, Simi Valley, Ca 93063 805-527-4498 RMIS Part No. 500760 TABLE OF CONTENTS INTRODUCTION General Description 3 General Precautions 3 INSTALLATION Base Preparation 6 Tower
More informationWT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual
WT-3131A Radio-controlled Analog Clock With Weather Forecast Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents/Additional Equipment 2 About WWVB 2 Detailed Set-Up Guide Battery Installation
More informationAssembly and Operation Manual. April 2016
Assembly and Operation Manual April 2016 Table of Contents What is in the OurWeather Box? 3 Step by Step Assembly 13 Building the Weather Sensors 18 Testing the OurWeather Weather Station 28 Power Up OurWeather
More information473 Dew Point Hygrometer
gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion
More informationWireless Weather Station. Instruction Manual
Wireless Weather Station Instruction Manual Congratulations on purchasing this state-of-the-art Weather Station as an example of fine design and quality piece of engineering. The operation of this product
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationLatest generation testo air velocity & IAQ probes with cable handle. Instruction manual
Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of
More informationPLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL
PLOW MOUNT KIT FOR POLARIS RANGER P/N 34-3010 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 34-0000 or 34-0070 Before you begin, please read these instructions and check to be sure all parts
More informationQUICK SET UP MANUAL WEATHER CENTER
QUICK SET UP MANUAL WEATHER CENTER Using 915MHz wireless transmission of weather data, this unique weather station can be powered using batteries for all your weather needs in the home or office. This
More informationSelf-Testing Prevectron 2 Millenium Lightning Conductor Set-up and Installation Manual
Self testing Prevectron 2 Millenium Lightning Conductor ENGLISH Self-Testing Prevectron 2 Millenium Lightning Conductor Set-up and Installation Manual S6.60T S4.50T S3.40T N.B. : Information and Specifications
More informationLinear measuring technology
Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability
More informationPLOW MOUNT KIT FOR YAMAHA VIKING P/N ASSEMBLY / OWNERS MANUAL. Application PLOW PUSH FRAME NO or
PLOW MOUNT KIT FOR YAMAHA VIKING P/N 34-5020 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 34-0000 or 34-0070 Before you begin, please read these instructions and check to be sure all parts
More informationLED light engine / OLED LED compact. Uengine DLE G2 integrated ADV
Uengine DLE G2 integrated ADV uengine DLE Product description Module with integrated electronics For downlights Light engine operating with 23 V AC Luminous flux range from 1,24 2,43 lm High system efficacy
More informationRoute and retain the clinometer cable so that it does not interfere with moving parts where the unit is mounted.
SYSTEM DESCRIPTION The AngleStar Protractor Systems are economical angle measurement devices. A system consists of a compact gravity-referenced clinometer connected to an associated liquid crystal, (LCD)
More informationLED light engines LED linear / area
Module LLE G2 55mm 4lm ADV Modules LLE ADVANCED Product description Ideal for linear and panel lights LED system solution with outstanding system efficiency up to 165 lm/w, consisting of linear LED modules
More informationWS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS. Figure 2. Figure 1
WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents 3 Additional Equipment 4 Quick Setup 5-8 Detailed Setup Guide Battery Installation 9-11 Setting
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationInstallation Manual. Installation manual for PerfectEnergy Solar Modules. Content
Installation manual for PerfectEnergy Solar Modules Content 1. Preface 2. Technical data/general 3. Safety instructions 4. Mechanical Installation 5. Electrical installation 6. Grounding 7. Maintenance
More informationS Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems
INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS Time base: 60 Hz (3-wire system) Quartz (2-wire system) Power input: 85 135 VAC / 60 Hz 7 28 VAC / 60 Hz Current consumption:
More informationRoHS. Versatile. X g. X 2 e
s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k
More informationMKIII -MB USER S GUIDE 09/18/18. Rev. 3
MKIII -MB USER S GUIDE 09/18/18 Rev. 3 Copyright 2018 by RainWise, Inc. All rights reserved. No part of this work may be reproduced in any form except by written permission of the publisher. All rights
More informationPHASED OUT. LED light engines LED linear / area. Module QLE G1 471x462mm 5000lm SNC Modules QLE ESSENCE
Product description Luminous flux: 5, lm per module Square module one module per luminaire nonselv (HV) and SELV (LV) variants High colour rendering index CRI 8 Small colour tolerance (MacAdam 4) Efficacy
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationCA84688 FAQS TABLE OF CONTENTS
CA84688 FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader TABLE
More informationLED light engines LED linear / area. Module QLE G3+ ADV Modules QLE ADVANCED
Module QLE G3 ADV Modules QLE ADVANCED Product description Ideal for linear and panel lights Luminous flux range from 1, 5,25 lm LED system solution with outstanding system efficacy up to 162 lm/w, consisting
More informationLED modules LED linear / area
Module LLE G4 16mm 65lm ADV Module LLE advanced Product description Ideal for compact linear luminaires designs Homogenous illumination thanks to small package distance SELV module the single module has
More informationLED light engines LED linear / area. Module CLE Quadrant G3 ADV Modules CLE ADVANCED
Module CLE Quadrant G3 ADV Modules CLE ADVANCED Product description Ideal for round shaped and flat ceiling and pendant luminaires THE solution to realise XXL luminaires For uniform illumination of prestige
More informationLufft MARWIS-UMB Mobil Advanced Road Weather Information Sensor
Lufft MARWIS-UMB Mobil Advanced Road Weather Information Sensor sion for precision passion pour la précision pasión por la precisión passione per la precisione a passion www.lufft.com/wondermadeingermany
More informationPHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 FOOD EXC
w Product description Application specific colours for attractive product presentation For spotlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 4,72 lm at tp = 65 C High
More informationPHASED OUT. LED light engines LED linear / area. Module CLE Quadrant G2 ADV Modules CLE ADVANCED
Product description Ideal for round shaped and flat ceiling and pendant luminaires THE solution to realise XXL luminaires For uniform illumination of prestige areas or rooms designed to impress High Output
More informationPHASED OUT. LED light engine / OLED LED compact. Module DLE G3 ADV Modules DLE
w LED light engine / OLED Product description For downlights Luminous flux up to 3,68 lm at tp = 65 C High efficacy up to 165 lm/w for the LED module at tp = 25 C High system efficacy up to 147 lm/w at
More informationLED light engine / OLED LED compact. Module DLE G3 ADV Modules DLE
w LED light engine / OLED Module DLE G3 ADV Modules DLE Product description For downlights Luminous flux up to 3,68 lm at tp = 65 C High efficacy up to 165 lm/w for the LED module at tp = 25 C High system
More informationState Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant PN-6K. Servise Manual
State Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant Night Sight PN-6K Servise Manual Contents 1. General directions 4 2. Specifications 5 3. Delivery set 6 4. Safety regulations
More informationCAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.
CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE. ON Press either brightness button ( + or - ) to turn on the sight. The sight is also programmed to turn on when it
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More informationTHM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist
THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,
More informationA Rain Sensitive House Window Closes Automatically When Raining
A Rain Sensitive House Window Closes Automatically When Raining House windows are sometimes opened when it rains and no body around to close them allowing rain going in side and damage the house. Information
More informationDrive electronics pq12
Drive electronics pq12 Amplifier module with constant current controller for proportional valves Control of one solenoid Easy mounting directly on bearing rails acc. to EN 50022 Standard voltage and current
More informationLufft MARWIS-UMB Mobil Advanced Road Weather Information Sensor
Lufft MARWIS-UMB Mobil Advanced Road Weather Information Sensor www.lufft.com/wondermadeingermany Professional Mobile Weather Data Recording. Forget black holes in your weather forecast. You waste too
More informationProduct manual. Mylos KNX Shutter actuator 2CSY1104C/S
Product manual Mylos KNX Shutter actuator 2CSY1104C/S Contents Contents 1 Technical features... 3 1.1 Technical data... 3 1.2 Connection diagram... 4 2 Commissioning... 5 2.1 Parameters... 5 2.1.1 General...
More informationWS-7211U Wireless 433 MHz Weather Station. Instruction Manual
WS-7211U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS Topic Page Quick Setup 3-5 Inventory of Contents 6-7 Detailed Setup Guide Battery Installation 7 Setting the Time 8 Features
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationLD-LP-LL-LC Rope Safety Switches with reset for emergency stop
TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks
More informationSC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004
SC125MS Stepper Motor Driver Salem Controls Inc. Last Updated 12/14/2004! Warning! Stepper motors and drivers use high current and voltages capable of causing severe injury. Do not operate this product
More informationAlphaLab Gaussmeter Model VGM -- Instructions
AlphaLab Gaussmeter Model VGM -- Instructions Power: As shipped, a standard 9 volt battery is installed. Battery life is about 10 hours (25 ma drain; 6.5 volt dropout). Low battery appears when about one
More informationWS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual
WS-7038U Wireless 433 MHz Miniature Rain Monitor Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents/ Additional Equipment 3 Quick Set-Up Guide 3 Detailed Set-Up Guide Battery Installation
More informationPHASED OUT. LED light engine / OLED LED compact. Module SLE G4 6mm R SNC, SLE G4 10mm R SNC China domestic Modules SLE ESSENCE
w LED light engine / OLED Product description For general lighting application Typ. luminous flux category: 3/6/8/1,2 lm High efficacy up to 113 lm/w for the LED module at tp = 25 C Small LES (light emitting
More informationSZ7001. Wireless ZIGBEE tipping bucket rain sensor. Product Overview. Dimensions. parameter. September, 2016 Rev.
SZ7001 Wireless ZIGBEE tipping bucket rain sensor http:// www.sonbus.com Product Overview Tipping bucket rain sensor for measuring the nature of rainfall, while rainfall is converted to digital information
More informationWeatherHub2 Quick Start Guide
WeatherHub2 Quick Start Guide Table of Contents 1 Introduction... 1 2 Packing List... 1 3 Connections... 1 4 IP Addressing... 2 5 Browser Access... 3 6 System Info... 3 7 Weather Station Settings... 4
More informationWeatherHawk Weather Station Protocol
WeatherHawk Weather Station Protocol Purpose To log atmosphere data using a WeatherHawk TM weather station Overview A weather station is setup to measure and record atmospheric measurements at 15 minute
More informationMinute Impulse Clock Controller I01DN
99b-mi USER S MANUAL Minute Impulse Clock Controller Mon Jun 01, 2009 12:00:00 PM DST HOLD ENTER KEY TO BEGIN CANCEL HR I01DN 97 West Street Medfield, MA 02052 U.S.A. (508) 359-4396 Pg. 2 of 20 TABLE OF
More informationPHS-25CW/3BW Benchtop ph Meter Instruction Manual
PHS-25CW/3BW Benchtop ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD PHS-W Series Benchtop ph Meter 1 Introduction Thank you for selecting the PHS-W series benchtop ph meter. This manual provides
More informationLED light engines LED linear / area
Module LLE G4 16mm 125lm ADV Module LLE ADVANCED Product description Ideal for compact linear luminaires designs Homogenous illumination thanks to small package distance SELV module the single module has
More informationOperating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014
Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5
More informationWS-7391U Wireless 433 MHz Radio-controlled Weather Station. Instruction Manual
WS-7391U Wireless 433 MHz Radio-controlled Weather Station Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents/Additional Equipment 3 About WWVB 4 Quick Set-Up Guide 5-6 Detailed Set-Up
More informationWEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather
WXT510 WEATHER MULTI-SENSOR Vaisala Weather Transmitter WXT510 Change the Way You Measure Weather Vaisala Weather Transmitter WXT510 The Most Essential of Weather The Vaisala Weather Transmitter WXT510
More informationHYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC
HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF
More informationSTATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016
APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission
More informationHeat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97
Heat Meter WR 200-D electronic computing device for heat quantity measuring Heat transfer medium water steam Any flow sensor with analog signal connectable 2 temperature inputs for Pt100 in four-wire circuit
More informationISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER
ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection
More informationPHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD
PHS-25CW/3BW Benchtop ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD PHS-W Series Benchtop ph Meter 1 Introduction Thank you for selecting the PHS-W series benchtop ph meter. This manual provides
More informationFAQS. La Crosse Technology, Ltd. Page 1
308-1412 FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader CONTENTS
More informationPHYS 1102 EXAM - II. SECTION: (Circle one) 001 (TH 9:30 AM to 10:45AM) 002 (TH 3:30 PM to 4:45 PM) You have 1 hr 45 minutes to complete the test
PHYS 1102 EXAM - II SECTION: (Circle one) 001 (TH 9:30 AM to 10:45AM) 002 (TH 3:30 PM to 4:45 PM) Your Name: Student ID: You have 1 hr 45 minutes to complete the test PLEASE DO NOT START TILL YOU ARE INSTRUCTED
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationTunable White LED compact
Module TW DLE G2 60mm 3000lm 927-965 DLE modules Product description module for Downlights with adjustable colour temperature from 2,700 to 6,500 K at constant luminous flux High colour rendering index
More informationW 9 L: Laser photoelectric switches: small, light and reliable
W 9 Laser photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 9 L: Laser photoelectric switches: small, light and reliable The
More information