SZ7001. Wireless ZIGBEE tipping bucket rain sensor. Product Overview. Dimensions. parameter. September, 2016 Rev.
|
|
- Tracey Craig
- 5 years ago
- Views:
Transcription
1 SZ7001 Wireless ZIGBEE tipping bucket rain sensor Product Overview Tipping bucket rain sensor for measuring the nature of rainfall, while rainfall is converted to digital information output in the form of binary representation, in order to meet the information transmission, processing, recording and displaying the need to wait. The instrument in strict accordance with national standards GB / T "tipping bucket rain gauge" design and produce. This instrument is a precision single tipping bucket rain gauge, the core components used dump three-dimensional streamlined design, the dump over the water more smooth and easy to clean. Dump angle when the instrument has been factory-adjusted to lock in the best angle position, simply follow the instructions required to install this dump and adjust the level of the base when installing the instrument can be put into use, and can not live longer tipping angle adjusting screw adjustment. The products are widely used for weather stations, hydrological stations, agriculture, forestry and other departments used to measure liquid precipitation, precipitation intensity and precipitation time. Parameters Dimensions parameter Technical Specifications Rain gage receiver size φ200mm Acute angle edge 40 ~45 Resolution 0.2mm Measuring range 0.01mm ~ 4mm / min (maximum allowed by rain intensity 8mm / min can be measured Measurement Accuracy ±3% communication method ZIGBEE wireless Working temperature -10 ~50 Relative humidity <95%(40 ) size φ216mm 460mm Operating Voltage DC12V September, 2016 Rev. 2 1 SZ7001
2 Installation and adjustment Notes 1. Check the box (1)Carefully read the product manual, packing list inventory equipment accessories are complete. (2)Check whether the appearance of damage to the instrument, with particular attention to preventing diversion sharp bumps tipper pivot shaft and both ends of the dump, and do not use your fingers touch the inner wall of tipper fouling. Before using the device to open the top cover, remove the fixed with a rubber band before normal use 2. Fabrication and installation of cement units Outdoor ground or roof installation, you should make the cement sets. Taiwan Cement exposed ground plane height of 22cm, dimensions: length 40cm width 40cm, which is the horizontal plane. When floor mounting, bearing rain mouth height from the ground plane distance should be 70cm. 3. Fixed instruments, adjust the level of rain bearing opening In the first stage the cement to play three deep mounting hole diameter φ12mm 8 ~ 10cm, the mounting holes are located on Φ240mm average was 120 circumference. The expansion bolt into the mounting hole, the instrument will be mounted on the base 3 expansion bolts, check with a spirit level after level of mouth bearing rain, with the locking nut three legs, and then remove the outer cylinder standby instrument and remove the rubber band fixed dump or cut. Failure and exclusion This table presents the general Symptom instrument may occur, causes and troubleshooting methods. Central Station manifestations Rain sensor fault Solution Hours not No description of the rain receive rain sensor signal output or Under inspection transmission line failure 1, the reed switch failure station 1, the 2, magnet and reed is too far away replacement reed 3, signal lines or falling off 2. Adjust the the wire 4, dump stuck 5, instrument jam distance reed 3, repair 4, excluding 5, clear the blockage 1, rain sensor offset dump flip angle, but this error is no 1, re-adjust the angle titration more than ± 10% 2, adjust the 2, magnet and reed poor distance location, resulting in good 3, anti-shake times and bad, so that part of adjustment September, 2016 Rev. 2 2 SZ7001
3 the signal missing 3, data acquisition stabilizer circuit parameters function failure 4, objective 4, compared with rain gauge measurement system with rain sensor farther apart or reasons, non-instrument malfunction strong winds Rainfall Check whether the outlet is Water treatment continued to flooding, especially after and re-install count, but the heavy rain reality did not rain Note: Symptom listed in the table is not necessarily the fault of their own rain gauge, after checking the instrument itself should also check for troubleshooting instrument qualifying transmission, data acquisition devices, telemetry terminals and other equipment is faulty, and excluded one by one to solve. Accuracy calibration Emergency Measures (customer self) 1, test tools: dedicated rainfall cylinder 1, a small dropper; 2, before the test to check: Before the test, first remove the stainless steel outer tube inspection equipment level bubble is centered, whether the flip dump flexible, cable wiring and check the water is smooth, then use the water to water funnel, Tipper fully wet; 3, water test Drip method using two-speed test equipment measurement accuracy, the method is as follows: Take water with a special cylinder rainfall amounts of 10mm, to funnel water through arbitrary rain intensity between 0 ~ 4mm of rain intensity slowly into the water on the dump bucket, until the next dump the last bucket not want to turn, that stop the water and then with a dropper quantitative measure of water, drop by drop added to the dump until the next dump flip stops dripping, followed by trial and error, dump record number of turns and water consumption. 0.2mm dump flipped 50 times, the consumption of water is 9.80 ~ 9.90mm, the instrument can be found tipping point angle normal, do not have to be adjusted; when poured water> 9.90mm, described Tipper tilt angle is too large, should increase the height adjustment screw; when pour water <9.80mm, described Tipper tilt angle is too small, should be appropriately reduced height adjustment screw; generally speaking, the adjustment screw revolution, to make precision changes from 2 to 3%. NOTE: This method only as a site emergency instrument calibration error with. Accurate calibration of the instrument error must be in accordance with national standards GB / T "tipping bucket rain gauge" requirements in rainfall intensity calibration or test rig will return to the factory calibration of the instrument. Rainfall output signal corresponding to the formula Switch count * 0.2mm = rainfall Eight, rainfall level Description The classification of rainfall, different departments have different standards. Meteorological Department: rainfall in a certain time fall into the water depth of the ground, expressed in millimeters. Said unit time rainfall intensity. Rain with rainfall intensity level to be divided as follows: Rainfall level 12 hours rainfall 24 hours rainfall ight rain 0.1~ ~9.9 Small to moderate rain 3.0~ ~16.9 Moderate rain 5.0~ ~24.9 Moderate to heavy rain 10.0~ ~37.9 Heavy rain 15.0~ ~49.9 Heavy rain 30.0~ ~74.9 Rainstorm 30.0~ ~99.9 Heavy rain storm 50.0~ ~174.9 Heavy Rain 70.0~ ~250.0 Heavy rain to rainstorm 105.0~ ~300.0 Rainstorm >140.0 >250.0 Flood control departments: a little water to a depth of rainfall per unit area is within a certain time landing on the ground or in millimeters. According to the National Civil Air Defense Office "Flood Control Handbook", where the 24-hour accumulated rainfall over 50 mm were defined as heavy rain. 12-hour and 24-hour rainfall intensity rainfall intensity rainfall size division level, as follows: Strong rain evel 12 hours rainfall 24 hours rainfall ight rain R12<5 R12<10 Moderate rain 5 R12<10 10 R12<25 Heavy rain 10 R12<30 25 R12<50 Rainstorm 30 R12<70 50 R12<100 Heavy Rain 70 R12< R12<200 Rainstorm 140 R R12 Hydrological Department: Generally speaking, rain, rain, rain, rain, etc., generally daily rainfall measured. ight rain to happen where rainfall of 10 mm or less; moderate daily rainfall of 10 to 24.9 mm; heavy rainfall of 25 to 49.9 mm; storm rainfall of 50 to 99.9 mm; September, 2016 Rev. 2 3 SZ7001
4 heavy rain rainfall of 100 to mm; King storm rainfall of 200 mm. In addition, people can also be determined from precipitation in rain levels: the next rain, rain generally legible, no floating phenomenon; fall to the ground, not on stone or tiles scattered; ground muddy shallow depression formed very slowly; at least more than two minutes before wet slate, tiles; only under the eaves dripping. Down in the rain, the rain, such as lines, raindrops are not easily distinguishable; landed hard on the roof tiles scattered rain; puddle puddles formed quickly; roof rustle. And when it rains, as rain poured down, blurred into pieces; landed on the roof tiles, stone or concrete can splash, pools formed quickly; there is the noise of the rain roof. Care and maintenance This instrument is a precision electronic products, proper care and maintenance to help protect the instrument performance and extend the life of the instrument, please note the following: 1, please use the instructions in accordance with the requirements of the proper use of the specification, then the money is incorrect may cause damage to the instrument. 2, do not use volatile liquids to clean the instrument, the instrument may cause discoloration deformation; a soft cloth to avoid scratching the protective film outside of the instrument, extend the life of the instrument. 3, the instrument should be handled with care, cannot be dropped or weight, this can cause deformation of the instrument, the internal circuit board damage. 4, do not touch sensitive parts of the instrument in the case of live, in order to affect the amount of results or cause damage to the internal circuitry of the instrument. 5. Do not dismantle and modify the instrument, so as to avoid damage to the instrument. 6, the application of the instrument with screws firmly fixed, otherwise it may damage the instrument. 7, the instrument is a precision single tipping bucket rain gauge, use the process to regular maintenance, cleaning and water dump hopper outlet. 8, regular inspection instrument supply voltage to ensure the normal operation of the instrument. Protocol 1 function code 0x Discover slave s Master packets The correct message from the device (0x01-0xFE 1 (0x01-0xFE 1 Function code (0x03 1 Function code (0x03 1 (2 bytes) Number (2 * number of 1 byte data area Register number (2 Data region ( number bytes) contents 2 * 1 CRC checksum (2 bytes) CRC checksum (2 bytes) 2 function code 0x set the number of slave devices to Master packets The correct message from the device (0x01-0xFE 1 (0x01-0xFE 1 Function code (0x06 1 Function code (0x06 1 (2 Number (2 * number of bytes) 1 byte data area Data written to the ( number 2 * 1 Data region ( number contents 2 * 1 CRC checksum (2 bytes) CRC checksum (2 bytes) Note: 1, CRC check code low front, high in the post,, number of s, data are MSB after; 2, word length is 16bit (two bytes). Register Description and Syntax (1) parameter data definition table Register Register The Register Data range Address (Hex) contents number of status (Hex) 0x0008 Rainfall 1 Read-only (0x00-0x7D0) Tip: Since December 20, 2013 all the sensors all changes of 0x002A, customers used the sensors 0x0010,0x0002,0x0000, amended protocol still support the above, customers do not need to make changes. September, 2016 Rev. 2 4 SZ7001
5 Register Address (Hex) 0x4000 Register contents Rainfall The number Register Data range of status (Hex) 1 Write 1~254 (0x01~0xFE) (2) Command Example: All command byte, number of bytes, data bytes MSB after; CRC checksum low byte first, high byte in the post. Read rainfall values: (02 from the device, baud rate 9600, N, 8,1) Functio n Code The number of CRC -H 0x02 0x03 0x00 0x08 0x00 0x01 0X05 0xFB Response from the device: Functio n Code The number of H 0x02 0x03 0x02 0x00 0x00 0xFC 0x44 Modify the device : ( 02, modified to 03) addres s Functi on Code The revised data H 0x02 0x06 0x40 0x00 0x00 0x03 0XDC 0x38 Response from the device: addres s Functi on Code The revised data H 0x03 0x06 0x40 0x00 0x00 0x03 0XDD 0xE9 September, 2016 Rev. 2 5 SZ7001
POINTS OF CAUTION BEFORE USE...
INSTRUCTION MANUAL NPN DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 6 points each (-I/-II, e-con connector) MODEL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the
More informationproduct manual H-3220A Benkelman Beam
05.12 product manual H-3220A Benkelman Beam General The H-3220A Benkelman Beam Apparatus is a convenient and accurate device used for measuring the deflection of flexible pavements under moving wheel
More informationMeteorological Service
Meteorological Service The Meteorological Service in Oman was established in 1973. Oman joined ICAO in 1973 Oman joined WMO in 1975. Meteorological Service is under the framework of the Directorate General
More informationRain Collector (# 7852 & 7852M)
Rain Collector (# 7852 & 7852M) This rain collector can be used with Vantage Pro2 weather stations, including Vantage Pro2, Vantage Pro2 Plus, and the Anemometer/Sensor Transmitter Kit. Note: Model number
More informationOASIS WIRELESS WEATHER STATION
User Manual 3910-B Royal Avenue, Simi Valley, Ca 93063 805-527-4498 RMIS Part No. 500760 TABLE OF CONTENTS INTRODUCTION General Description 3 General Precautions 3 INSTALLATION Base Preparation 6 Tower
More informationMET ONE RAIN GAGE MODELS 380, 385, 380M, 385M
MODELS 380, 385, 380M, 385M REVISION: 2/96 COPYRIGHT (c) 1993-1996 CAMPBELL SCIENTIFIC, INC. WARRANTY AND ASSISTANCE The MET ONE RAIN GAGE--MODELS 380, 385, 380M, 385M is warranted by CAMPBELL SCIENTIFIC,
More informationMeteorological Station P03/3-RS485-WAGO
Meteorological Station P03/3-RS485-WAGO Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93 97-0
More informationCommunity Collaborative RAin, Hail and Snow network. CoCoRaHS.
Community Collaborative RAin, Hail and Snow network CoCoRaHS http://ks.cocorahs.org An observer s guide to measuring and reporting precipitation data! Equipment Each volunteer participating in CoCoRaHS
More informationWS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual
WS-7038U Wireless 433 MHz Miniature Rain Monitor Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents/ Additional Equipment 3 Quick Set-Up Guide 3 Detailed Set-Up Guide Battery Installation
More informationWS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual
WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents 2 Additional Equipment 2 Quick Setup 3 Detailed Setup Guide
More informationWeather Station P03/3-Modbus-GPS for Modbus
Weather Station P03/3-Modbus-GPS for Modbus Technical specifications and installation instructions Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49
More informationAssembly Instructions for the 1-Wire Weather Station V2.0/V3.0
Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0 Tools and Supplies Required (not included): Phillips screwdriver 3/8" wrench Drill with 5/32" bit "U" type mounting bracket (i.e., part number
More informationHD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION
HD2016 [ GB ] Weighing rain gauge Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION [ GB ] HD2016 Weighing rain gauge [ GB ] HD2016 is a rain gauge that detects the weight of the
More informationWeather Station P03/3-RS485-GPS with RS485 Interface
Weather Station P03/3-RS485-GPS with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0)
More informationWhat is the maximum distance I can have the remote sensors from the display?
What is the maximum distance I can have the remote sensors from the display? The maximum open-air distance is 100 meters in a straight line although you should take into account the environment, distance
More informationMKIII -MB USER S GUIDE 09/18/18. Rev. 3
MKIII -MB USER S GUIDE 09/18/18 Rev. 3 Copyright 2018 by RainWise, Inc. All rights reserved. No part of this work may be reproduced in any form except by written permission of the publisher. All rights
More informationHigh Resolution High Sensitivity SDR Super Wide Dynamic Camera
High Resolution High Sensitivity SDR Super Wide Dynamic Camera INSTRUCTION MANUAL 15-CA45R 15-CA45RC CONTENTS PRECAUTION.2 FEATURES..3 DIMENSION...3 INSTALLATION...4 SPECIFICATIONS..5 BASIC TECHNICAL DATA
More informationWT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual
WT-3131A Radio-controlled Analog Clock With Weather Forecast Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents/Additional Equipment 2 About WWVB 2 Detailed Set-Up Guide Battery Installation
More informationStructure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor
Rain detection sensor General Description Driving rain and its effective management are critical factors in determining the durability of building enclosures. An accurate measurement of driving rain can
More informationWeatherHawk Weather Station Protocol
WeatherHawk Weather Station Protocol Purpose To log atmosphere data using a WeatherHawk TM weather station Overview A weather station is setup to measure and record atmospheric measurements at 15 minute
More informationWeather Station P03/3-RS485 with RS485 Interface
Weather Station P03/3-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70
More informationWireless Weather Station. Instruction Manual
Wireless Weather Station Instruction Manual Congratulations on purchasing this state-of-the-art Weather Station as an example of fine design and quality piece of engineering. The operation of this product
More informationRichter Optica. Instructions for Model: S850 Stereo Zoom Microscope
Richter Optica info@richter-optica.com Instructions for Model: S850 Stereo Zoom Microscope Microscope Head Focus Knob Stage Clips Zoom Knob C-Mount Adapter Eyepiece Focusing Holder Focusing Holder Set
More informationAIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL
AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E
More informationModel: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started
Model: WT-3181PL Instruction Manual DC: 041614 18 Indoor/Outdoor Atomic Wall Clock Round Battery Cover Get Started Step 1: Remove the round battery cover from the back of the clock. Step 2: Insert 1 fresh
More informationVolumetric Measurement Techniques. Technique #1 Use of a Burette. Technique #2 Use of a Pipette. Technique #3 Use of a Volumetric Flask
Volumetric Measurement Techniques Technique #1 Use of a Burette Technique #2 Use of a Pipette Technique #3 Use of a Volumetric Flask Technique #4 Use of a Bottle-Top Dispenser Last updated 12/6/2009 5:46
More informationS Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems
INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS Time base: 60 Hz (3-wire system) Quartz (2-wire system) Power input: 85 135 VAC / 60 Hz 7 28 VAC / 60 Hz Current consumption:
More informationNOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL
NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL REVISION DATE: OCT 2005 Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify
More informationiweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved.
iweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved. Table of contents: 1 Introduction...3 2 Station Components...4 3 STATION INSTALLATION PROCEDURE...5 4 Specifications...11
More informationVOLUME 3 HYDRO-METEOROLOGY
Government of India & Government of The Netherlands DHV CONSULTANTS & DELFT HYDRAULICS with HALCROW, TAHAL, CES, ORG & JPS VOLUME 3 HYDRO-METEOROLOGY FIELD MANUAL - PART III AUTOMATIC RAINGAUGE STATION
More informationFischer 1508BTH-45 5" Brass Barometer with Temperature & Humidity User Manual
Fischer 1508BTH-45 5" Brass Barometer with Temperature & Humidity User Manual Table of Contents 1. Introduction... 2 2. Care and Cleaning... 2 3. Barometer Operation... 2 3.1 How the aneroid barometer
More informationWEATHER STATION FOR SOLAR FARM MONITORING
WEATHER STATION FOR SOLAR FARM MONITORING SOLAR FARM MONITORING SYSTEM: Measures global, horizontal, & background irradiance. Measures wind speed, wind direction, ambient temperature, and relative humidity.
More informationApplications. Remote Weather Station with Telephone Communications. Tripod Tower Weather Station with 4-20 ma Outputs
Tripod Tower Weather Station with 4-20 ma Outputs Remote Weather Station with Telephone Communications NEMA-4X Enclosure with Two Translator Boards and Analog Barometer Typical Analog Output Evaporation
More informationField Pro Operation and Installation Manual
Field Pro Operation and Installation Manual Xtreme Research Corporation SkyScan Division P.O. Box 336, Port Richey, FL 34673-0336 1-800-732-0665 Table of Contents 1. Installation 3 2. Operation 5 3. Care
More informationHS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)
HS515G-M PARALOW Circle Dot Sight User's Manual Multi Reticle Holosun Technologies Inc. Phone: (909) 594-2888 Fax: (909) 598-4888 E-mail: info@holosun.com COLOR www.holosun.com PARALOW HS515G-M PARALOW
More informationWS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS. Figure 2. Figure 1
WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents 3 Additional Equipment 4 Quick Setup 5-8 Detailed Setup Guide Battery Installation 9-11 Setting
More informationFischer Instruments Stainless Steel Barometer User Manual
Fischer Instruments 15-01 Stainless Steel Barometer User Manual Table of Contents 1. Introduction... 2 2. Care and Cleaning... 2 3. Barometer Operation... 2 3.1 How the aneroid barometer works... 2 3.2
More informationElectron Microscopy Sciences INSTRUCTION MANUAL. Stereo Microscopes Non-illuminated Stands
Electron Microscopy Sciences 1 INSTRUCTION MANUAL Stereo Microscopes Non-illuminated Stands Model GL7-207: Binocular, 6.5:1 Zoom Ratio 10X to 65X, smooth ball bearing construction and Model GL7-307: Trinocular,
More informationFischer Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual
Fischer 4673-22 Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual Table of Contents 1. Introduction... 2 2. Care and Cleaning... 2 3. Barometer Operation... 2 3.1 How the aneroid
More informationAssembly and Operation Manual. April 2016
Assembly and Operation Manual April 2016 Table of Contents What is in the OurWeather Box? 3 Step by Step Assembly 13 Building the Weather Sensors 18 Testing the OurWeather Weather Station 28 Power Up OurWeather
More informationCOMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE
3 0 15 15 E OWNER S MANUAL COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE 5 W 60 W 30 W 45 W Zhumell customers know that there are plenty of ways to experience the world. They also understand
More informationOPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820
Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.
More informationRemote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.
Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.
More informationThermal Cube. Custom-built Heat Flux Sensor
Thermal Cube Custom-built Heat Flux Sensor Specifications and Construction MR. RAZIM REFAI MR. SHAMMAWI ANDERSON DR. ANDRÉ MCDONALD Table of Contents 1. Introduction... 2 1.1 Specifications [1]... 2 1.2
More informationDIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION
DIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.11.16
More informationAcceleration/Velocity/Displacement VIBRATION METER
Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex
More informationSTATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016
APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission
More informationAmbient Weather WS-152B 6" Contemporary Barometer User Manual
Ambient Weather WS-152B 6" Contemporary Barometer User Manual Table of Contents 2. Introduction... 2 3. Preparation... 2 4. Care and Cleaning... 2 5. Barometer Operation... 2 4.1 How the aneroid barometer
More informationOPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820
Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.
More informationINSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles
INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: 78950 (50 ), 78954 (54 ), or 78960 (60 ) Application: All Terrain Vehicles Your safety, and the safety of others, is very important. To help you make
More informationInstruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector
Solar Weather Centre With Wireless Weather Vane Solar Powered Outdoor Weather Data Collector Indoor Receiver Instruction Manual Product Code: WS5056C TECHNICAL DETAILS Thank you for purchasing the Holman
More informationFischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual
Fischer Instruments 1535-06 Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual Table of Contents 1. Introduction... 2 2. Care and Cleaning...
More informationInstallation Manual. Installation manual for PerfectEnergy Solar Modules. Content
Installation manual for PerfectEnergy Solar Modules Content 1. Preface 2. Technical data/general 3. Safety instructions 4. Mechanical Installation 5. Electrical installation 6. Grounding 7. Maintenance
More informationP03/3-RS485-WAGO. Weather Station with RS485 Interface. Technical specifications and installation instructions
EN P03/3-RS485-WAGO Weather Station with RS485 Interface Technical specifications and installation instructions Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone
More informationBEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D
INSTRUCTION MANUAL PNP DISCRETE INPUT & PNP TRANSISTOR OUTPUT MODULE, 6 points each (High-speed Link System, e-con connector) R7KDH--DACD MODEL R7KDH--DACD BEFORE USE... Thank you for choosing M-System.
More informationSKF actuators available for quick delivery. Selection guide
SKF actuators available for quick delivery Selection guide A wide range of SKF actuators available for quick delivery Industrial actuator 24 Volt DC Load range 1 000 to 4 000 N Speed range 5 to 52 mm/s
More informationproduct manual H-4204 Proving Ring Penetrometer
05.09 product manual H-4204 Proving Ring Penetrometer nnmm Handle Proving Ring Extension Rod Coupler Penetration Rod Cone Figure #1 General Information The Proving Ring Penetrometer is a cone type of penetrometer
More informationMODBUS Protocol for CS141 network card families
Last update: 20/09/208 MODBUS Protocol for CS4 network card families Summary. MODBUS PROTOCOL... 2.. MODBUS COMMUNICATION PARAMETERS... 2.2. AVAILABLE MODBUS FUNCTION CODES... 2.3. EXCEPTION CODES... 3
More informationDifferential Pressure Sensor
Differential Pressure Sensor MDP200 Series Features Pressure range up to ±500Pa with high accuracy of ±3.0% m.v. Pressure based on thermal micro-flow measurement Outstanding hysteresis and repeatability
More informationCL-L102-C7D. 1. Scope of Application. These specifications apply to LED package, model CL-L102-C7D. 2. Part code
Specification sheet 1/10 1. Scope of Application These specifications apply to LED package, model. 2. Part code Series L102 : High power LED for general lighting Watt Class C7 : 7 watt class package Lighting
More informationCS Series. Capacitance Type. Type. Proximity Sensor. Features
INFORMATI Series Features Capacitance Type - Metal cylinder/resin cylinder/square type - Non-metal objects such as wood, paper, plastic and water can be detected. - The operating distance is adjustable
More informationGOING WITH THE FLOW (1 Hour)
GOING WITH THE FLOW (1 Hour) Addresses NGSS Level of Difficulty: 3 Grade Range: 3-5 OVERVIEW In this activity, students use a stream table to model the processes of erosion and streambed formation. The
More informationHT600 Dat e Code: 2 - HT MW Purchase Date: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE. All Rights Reserved
We strive to ensure that our products are of the highest quality and free of manufacturing defects or missing parts. However, if you have any problems with your new product, D O NOT RETURN IT TO THE STORE,
More informationQuick Reference. Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20
Quick Reference for Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20 852 Feehanville Drive Mt. Prospect, IL 60056 Telephone: (847) 299-9550 Fax: (847) 759-3091 2009 CUMMINS-ALLISON
More informationNJ Community Collaborative Rain, Hail and Snow Network
NJ Community Collaborative Rain, Hail and Snow Network Mathieu Gerbush NJ Assistant State Climatologist/Climate Services Co-CoCoRaHS Coordinator NJ Agricultural Experiment Station School of Environmental
More informationSkyScan EWS-PRO - Manual -
INTRODUCTION SkyScan EWS-PRO - Manual - EWS-Pro gives you advance weather warning technology you can use at home, indoors or out, and take wherever you go, for any kind of outdoor activity. Your EWS-Pro
More informationCONTENTS. La Crosse Technology, Ltd. Page 1
WS-9133BK-IT- WS-9133T-IT FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationWS-9018U Wireless Weather Station. Instruction Manual
WS-9018U Wireless Weather Station Instruction Manual Contents Page 1. Functions of the Weather Station....3 2. Safety notes...3 3. Product features....4 4. Getting started....4 5. Quick Set Up...5 6. Setting
More informationLatest generation testo air velocity & IAQ probes with cable handle. Instruction manual
Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of
More informationWEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather
WXT510 WEATHER MULTI-SENSOR Vaisala Weather Transmitter WXT510 Change the Way You Measure Weather Vaisala Weather Transmitter WXT510 The Most Essential of Weather The Vaisala Weather Transmitter WXT510
More informationOperating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2
Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2 P/N VALTOL-KT2 Revision 2.0 October 7, 2014 Prepared by: Quality Lab Accessories, LLC 100 Emlen Way, Suite 108 Telford,
More informationOPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000
3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a
More informationQUICK SET UP MANUAL WEATHER CENTER
QUICK SET UP MANUAL WEATHER CENTER Using 915MHz wireless transmission of weather data, this unique weather station can be powered using batteries for all your weather needs in the home or office. This
More informationWebsite Phone Mobile OVERVIEW Davis Vantage Pro2 Weather Station
OVERVIEW If you're looking for a superior weather station, the Davis Vantage Pro2 Weather Station is as good as they come! Vantage Pro2 offers the professional weather observer and the serious weather
More informationA Rain Sensitive House Window Closes Automatically When Raining
A Rain Sensitive House Window Closes Automatically When Raining House windows are sometimes opened when it rains and no body around to close them allowing rain going in side and damage the house. Information
More informationDevice Specifications
Manual Device Specifications PART NUMBER LCGATEWAY ELECTRICAL The Lightcloud Gateway is designed to be hard-wired to AC power by a qualified electrician. INPUT 120-277 VAC, 50/60 Hz 60-45mA BATTERY Li-ion
More informationnufacturing Company, L.P San Felipe, Suite
REPAIR PARTS (2,3,4) Multi Zone Heat Pump Outdoor Unit 2MXS18GVJUAA 3MXS24JVJUAA 4MXS32GVJUAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to
More informationnufacturing Company, L.P San Felipe, Suite
Mini-Split Heat Pump Outdoor Unit RXS09LVJU RXS12LVJU RXS15LVJU RXS18LVJU RXS24LVJU REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is
More informationOverview of the Thunderbird Micronet
Fall 2004 Dr. Petra Klein Sean Arms Overview of the Thunderbird Micronet Introduction The Lake Thunderbird Micronet is a micrometeorological measurement network intended to obtain data on fine-scale spatial
More informationMemo. I. Executive Summary. II. ALERT Data Source. III. General System-Wide Reporting Summary. Date: January 26, 2009 To: From: Subject:
Memo Date: January 26, 2009 To: From: Subject: Kevin Stewart Markus Ritsch 2010 Annual Legacy ALERT Data Analysis Summary Report I. Executive Summary The Urban Drainage and Flood Control District (District)
More informationQuality assurance for sensors at the Deutscher Wetterdienst (DWD)
Quality assurance for sensors at the Deutscher Wetterdienst (DWD) Quality assurance / maintenance / calibration Holger Dörschel, Dr Tilman Holfelder WMO International Conference on Automatic Weather Stations
More informationMonitoring the world around us since Rainfall Measurement
Monitoring the world around Rainfall Measurement R W Munro Limited Monitoring the World Around us Since 1864 The Founder Robert William Munro, F.R.Met.Soc. 1839-1912 Established in 1864, R W Munro has
More informationAmbient Weather DHR70B-BRASS Handheld Fishing Barometer User Manual
Ambient Weather DHR70B-BRASS Handheld Fishing Barometer User Manual Table of Contents 1. Introduction... 2 2. Preparation... 2 3. Care and Cleaning... 2 4. Aneroid Barometer... 2 4.1 How the aneroid barometer
More informationInterview with Dr. Jaya Singh. 1. How critical is weather monitoring in a solar power plant and what are all the parameters to be monitored?
Interview with Dr. Jaya Singh Dr. Jaya Singh is an entrepreneur and scientist with experience in a range of industries including biotech, environmental sciences, and agriculture. She currently drives strategy
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully
More informationOperating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014
Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5
More informationRain Watch TM Set up Manual. IC System with Rain Bird IC CONNECT
Rain Watch TM Set up Manual IC System with Rain Bird IC CONNECT December 2018 Table of Contents Required materials to configure Rain Watch TM... 3 Installation... 4 Location... 4 Field Installation...
More informationAutomatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR
Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR CST/Berger 2001 SAL 20/24/28/32 PAGE 1 REV. C 071803 Automatic Level Maintenance Manual User Calibration and Testing... 3 Circular
More informationTHE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP
I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER
More informationtechnical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )
Installation Instructions: Wall-Mount Dewpoint Probe (809-2011) The HMW90 Wall-Mount Dewpoint Probe (P/N 809-2011) HMW90 measures dewpoint for indoor applications such as anti-sweat heater control and
More informationTelescopic auto dimension measuring system
- 0 - Contents Chapter One: Brief introduction 2 Chapter Two: Safety cautions 3 Chapter Three: Spare parts list and name 4 Chapter Four: User manual 7 I. Distance between 250~1140mm (M3:250~900mm) II.
More informationOPERATING INSTRUCTIONS Recording Rain Gauge 1509
Recording Rain Gauge according to Hellmann Model 1509-10 Model 1509-20 Model 1509-x H42 Chart speed 10 mm/h Chart speed 20 mm/h...with heating device In accordance with the guidelines of the WMO and of
More informationHigh Resolution High Sensitivity HDR Wide Dynamic Dome Camera
High Resolution High Sensitivity HDR Wide Dynamic Dome Camera INSTRUCTION MANUAL 15-CD43RVB 15-CD43RVBC 15-CD43RV 15-CD43RVC 15-CD43RVBI 15-CD43RVBIC 15-CD43RVI 15-CD43RVIC CONTENTS PRECAUTION.2 FEATURES..3
More informationINSTRUCTIONS FOR ATTACHING THE NORDIC PLOW TO THE ACTION TRACKCHAIR
1 INSTRUCTIONS FOR ATTACHING THE NORDIC PLOW TO THE ACTION TRACKCHAIR Nordic Auto Plow LLC is pleased to provide a plow blade that can be used with your Action Trackchair year round. We are not affiliated
More informationDHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual
DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual WD1063 Rev B Revised 02/23/15 Wahl Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131
More informationu s e r m a n u a l w w w. v e l a. E U
u s e r m a n u a l 100 w w w. v e l a. E U content 1.0. introduction...................................................... 3 1.1. safety.............................................................. 3
More informationWARNING. INJURY HAZARD Failure to observe these instructions could lead to severe injury or death.
INSTALLATION INSTRUCTIONS ATV Front Plow Mount Kit Part Number: 80031 Applications: 2007+ Honda Rancher 420 2007+ Honda Rancher ES 420 2009+ Honda Rancher AT 420 *Not compatible with 2.5ci or A2000 winches
More informationAltazimuth Mount. Altazimuth Mount
instruction Manual Orion VersaGo II HD Altazimuth Mount #10104 Orion VersaGo II Altazimuth Mount #10105 #10104 #10105 Providing Exceptional Consumer Optical Products Since 1975 OrionTelescopes.com Customer
More informationHARTING D-Sub Selection Guide
HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,
More information