Zavod za metrologiju Sektor za metrološku sljedivost i državne etalone

Size: px
Start display at page:

Download "Zavod za metrologiju Sektor za metrološku sljedivost i državne etalone"

Transcription

1 Dodatak Sertifikatu o akreditaciji sa akreditacionim brojem L K Annex to Accreditation Certificate - Accreditation Number L K Standard: MEST EN ISO/IEC 17025:2011 Datum dodjele / obnavljanja akreditacije / Akreditacija važi do: Accreditation is valid to: Akreditovana laboratorija za kalibraciju Accredited laboratory for calibration Zavod za metrologiju Sektor za metrološku sljedivost i državne etalone Kralja Nikole 2 Podgorica Bureau of metrology Sector of metrological traceability and national measurement standards Kralja Nikole 2 Podgorica Područje akreditacije / Scope of accreditation: Kalibracija mjerila mase Kalibracija mjerila temperature Kalibracija mjerila zapremine od stakla i mjerila zapremine sa klipom Kalibracija etalon prelivnih pipeta i mjernih posuda Kalibracija mjerila dužine Kalibracija mjerila pritiska Kalibracija mjerila električnih veličina Kalibracija mjerila frekvencije i vremenskog intervala of mass gauges of temperature gauges of laboratory glassware and piston-operated volumetric apparatus of etalons of over flow pipettes and standard capacity measures of length gauges of pressure of electrical quantities of frequency and time interval Q a, izdanje /izmjena 1/2, datum: Strana: 1/30

2 Detaljan obim akreditacije/ Detailed scope of accreditation Laboratorija za masu, Kralja Nikole 2, Podgorica * Metoda se sprovodi na terenu ** Metoda se sprovodi u Laboratoriji i na terenu 1. veličina/predmet item range 1 and 1 mg 0,0020 mg 2. 2 mg 0,0020 mg 3. 5 mg 0,0020 mg mg 0,0025 mg mg 0,0030 mg mg 0,0040 mg mg 0,0050 mg Konvencionalna masa/tegovi klase tačnosti 200 mg 500 mg 0,0060 mg 0,0080 mg E2, F1, F2, g 0,010 mg Masa M1, M2, M g 0,012 mg Mass Conventional g 0,016 mg mass /Weights of Classes E2, F1, F2, M1, M2, M3 10 g 20 g 0,020 mg 0,025 mg g 0,030 mg g 0,050 mg g 0,10 mg g 0,25 mg kg 0,50 mg kg 1,0 mg kg 2,5 Mg OIML R111/ Izdanje 2004 OIML R111/ Edition 2004 Q a, izdanje /izmjena 1/2, datum: Strana: 2/30

3 veličina/predmet item range 1 and kg 5,0 Mg g m c 0,016 mg g < m c 10 g 0,030 mg g < m c 100 g 0,066 mg Konvencionalan 26. a masa/tegovi 100 g < m c 205 g 0,140 mg 27. slobodnih 205 g < m c 220 g 9,6 mg nazivnih masa 28. Masa 220 g < m c 500 g 10,6 mg Mass Conventional g < m mass/weights c 1010 g 11,8 mg with free nominal masses 1010 g < m c 5000 g 5 kg < m c 10 kg 12,1 mg 14,3 mg kg < m c 20 kg 19,2 mg kg < m c 30 kg 24,8 mg kg < m c 50 kg 35,2 mg In house procedure QP.5.4/LM-02, Izdanje / Issue 02/03, m 0,02 g 0,0050 mg 36. 0,02 g < m 0,05 g 0,0064 mg 37. 0,05 g < m 0,1 g 0,0079 mg 38. 0,1 g < m 0,2 g 0,0095 mg Masa Mass *Vage Weighing instruments 0,2 g < m 0,5 g 0,5 g < m 1 g 1 g < m 2 g 0,013 mg 0,016 mg 0,019 mg g < m 5 g 0,025 mg g < m 10 g 0,033 mg EURAMET/cg18/ v.4.0 (11/2015) ** Guidelines on the of n-automatic Weighing Instruments rev g < m 20 g 0,041 mg g < m 50 g 0,061 mg Q a, izdanje /izmjena 1/2, datum: Strana: 3/30

4 veličina/predmet item range 1 and g < m 100 g 0,13 mg g < m 150 g 0,18 mg g < m 200 g 0,21 mg g < m 220 g 0,25 mg g < m 500 g 0,56 mg g < m 520 g 0,59 mg g < m 600 g 2,3 mg g < m 1,0 kg 2,6 mg 54. 1,0 kg < m 1,2 kg 2,7 mg 55. 1,2 kg < m 2,0 kg 21 mg EURAMET/cg18/ v.4.0 (11/2015) ** Guidelines on the of n-automatic Weighing Instruments rev ,0 kg < m 5,0 kg 23 mg 57. 5,0 kg < m 10,1 kg 28 mg ,1 kg < m 15,0 kg 0,22 g ,0 kg < m 20,1 kg 0,22 g ,1 kg < m 30,0 kg 0,30 g ,0 kg < m 50,0 kg 0,37 g ,0 kg < m 64,1 kg 0,44 g ,1 kg < m 77,0 kg 2,2 g 64. *Vage Masa 77,0 kg < m 100 kg 8,8 g Weighing 65. Mass instruments 100 kg < m 150 kg 13 g kg < m 200 kg 18 g kg < m 300 kg 27 g Q a, izdanje /izmjena 1/2, datum: Strana: 4/30

5 veličina/predmet item range 1 and kg < m 400 kg 43 g kg < m 500 kg 53 g kg < m 600 kg 63 g kg < m 700 kg 82 g kg < m 800 kg 89 g kg < m 900 kg 97 g kg < m 1000 kg 106 g kg < m 1100 kg 115 g kg < m 1200 kg 124 g kg < m 1300 kg 133 g kg < m 1400 kg 142 g EURAMET/cg18/ v.4.0 (11/2015) ** Guidelines on the of n-automatic Weighing Instruments rev kg < m 1500 kg 151 g kg < m 1600 kg 192 g kg < m 1700 kg 200 g kg < m 1800 kg 208 g kg < m 1900 kg 216 g kg < m 2000 kg 222 g Q a, izdanje /izmjena 1/2, datum: Strana: 5/30

6 Detaljan obim akreditacije/ Detailed scope of accreditation Laboratorija za temperaturu, Kralja Nikole 2, Podgorica * Metoda se sprovodi na terenu ** Metoda se sprovodi u Laboratoriji i na terenu 1. Temperatura Temperature veličina/predm et item Temperatura/ Stakleni termometri punjeni sa tečnošću Temperature /Liquid-in-glass thermometers range 80 C do/to -58 C (rezolucija 0,5 C) 58 C do/to +5 C (rezolucija 0,01 C i 0,02 C) +5 C do/to +80 C (rezolucija 0,01 C i 0,02 C) +80 C do/to +210 C (rezolucija 0,01 C i 0,02 C) 1 and 0,2 C 0,03 C 0,03 C 0,03 C NIST Special Publication 1088/ C do/to +278 C (rezolucija 0,1 C) 0,06 C 2. Temperatura Temperature Temperatura/ Indikatorski termometri koji imaju sondu i odgovarajući indikatorski dio (digitalni i analogni) Temperature/Se nsors with display unit -80 C do/to +5 C +5 C do/to +80 C +80 C do/to +278 C +278 C do/to +425 C +425 C do/to +650 C 0,02 C 0,02 C 0,02 C 0,2 C 0,35 C EURAMET/cg- 11/ v.02 (03/2011) 3. Temperatura Temperatura/ -80 C do/to +5 C 20 mk Q a, izdanje /izmjena 1/2, datum: Strana: 6/30

7 Temperature veličina/predm et item Platinski otpornički termometar (PRT/IPRT) range +5 C do/to +80 C +80 C do/to +278 C +278 C do/to +425 C +425 C do/to +650 C 1 and 20 mk 20 mk 200 mk 350 mk DAkkS DKD R 5-1:2010 Temperature/Re sistance thermometers Temperatura Temperature Temperatura Temperature Temperatura Temperature Temperatura/ Termoelementi (TC) Temperature/ Base metal Thermocouples Temperatura/ Zračni senzori Temperature/Air temperature thermometers Relativna vlažnost/ Mjerila relativne vlažnosti Relative Humidity/ Relative humidity gauges -80 C do/to +5 C +5 C do/to +80 C +80 C do/to +278 C +278 C do/to +425 C +425 C do/` +650 C 200 mk 200 mk 250 mk 350 mk 450 mk EURAMET/cg- 8/ v.2.1 (10/2011) -75 ᵒC do/to 20 ᵒC 1,2 ᵒC Direktna 20 ᵒC do/to 30 ᵒC 0,20 ᵒC Direct method 30 ᵒC do/to 100 ᵒC 0,50 ᵒC 100 ᵒC do/to 150 ᵒC 1,0 ᵒC (10-20) ᵒC; (66-90) % RH (10-20) ᵒC; 90 % RH (20-40) ᵒC; (34-50) % RH (20-40) ᵒC; (50-90) % RH 20 ᵒC; 90 % RH (40-70) ᵒC; (10-90) % RH 2,0 % RH 2,5 % RH 1,0 % RH 2,0 % RH 2,5 % RH 2,0 % RH In house procedure QP.5.4/11-LT 01/02, Direktna Direct method QP.5.4/10-LT 01/02, Q a, izdanje /izmjena 1/2, datum: Strana: 7/30

8 7. 8. Temperatura Temperature Temperatura Temperature veličina/predm et item Temperatura/ Temperaturne komore Temperature/ Temperature chambers Temperatura/ Peći Temperature/ Furnaces range 1 and -100 ᵒC do/to -20 ᵒC 1,5 ᵒC -20 ᵒC do/to 50 ᵒC 0,4 ᵒC 50 ᵒC do/to 100 ᵒC 0,5 ᵒC 100 ᵒC do/to 200 ᵒC 1,0 ᵒC 200 ᵒC do/to 1000 ᵒC 2,0 ᵒC Direktna Direct method QP.5.4/09-LT 01/03, ** EURAMET cg- 20/v.5 (09/2017) DKD-R 5-7 ( of Climatic Chambers) ** Metoda A i B za komore V<2000l, Metoda C za sve zapremine Methods A and B for chambers V<2000l, Method C for all volumes Direktna Direct method QP.5.4/09-LT 01/03, Q a, izdanje /izmjena 1/2, datum: Strana: 8/30

9 Temperatura Temperature Temperatura Temperature veličina/predm et item Temperatura i relativna vlažnost/ Klimatske komore do 2000 l Temperature and relative humidity/ Climate chambers up to 2000 l Termostatirani mediji kupatila Temperature/ Temperature baths range 10 ᵒC do/to 70 ᵒC 10 % RH do/to 50 % RH 50 % RH do/to 90 % RH 1 and 0,5 ᵒC 2,0 % RH 2,5 % RH -80 ᵒC do/to 150 ᵒC 0,05 ᵒC Direktna Direct method QP.5.4/09-LT 01/03, EURAMET cg- 20/v.5 (09/2017) DKD-R 5-7 Metoda/Metods A, B i C QP.5.4/09-LT 01/03, ** Q a, izdanje /izmjena 1/2, datum: Strana: 9/30

10 Detaljan obim akreditacije/ Detailed scope of accreditation Laboratorija za dužinu, Kralja Nikole 2, Podgorica * Metoda se sprovodi na terenu ** Metoda se sprovodi u Laboratoriji i na terenu 1. Dužina Length 2. Dužina Length veličina/ predmet item Planparalelne granične mjere od čelika /centralna dužina Steel gauge blocks/central length Mikrometri za spoljašnja mjerenja (klasična skala) External micrometer (classical scale) Mikrometri za spoljašnja mjerenja (digitalna skala) External micrometer (digital scale) range 0,5 mm-100 mm 0 mm 150 mm (rezolucija/resolution 0,001 mm) 0 mm 150 mm (rezolucija/resolution 0,001 mm) 0 mm 150 mm (rezolucija/resolution 0,001 mm) 1 and (0,054+1,2 L) µm, L u/in m (0,7 +8 L) µm, L u/in m (2,4 +8 L) µm, L u/in m (1,3 + 8 L) µm, L u/in m Metoda poređenja Comparison (differential) In house pr QP.5.4/01-LL izdanje/ Issue 02/03, Direktna Direct method QP.5.4/02-LL izdanje/ Issue 02/03, Dužina Length Pomična mjerila (digitalna skala) Calipers (digital scale) 0 mm 300 mm (rezolucija/resolution 0,01 mm) (9 +13 L) µm, L u/in m Direktna Direct method Q a, izdanje /izmjena 1/2, datum: Strana: 10/30

11 veličina/ predmet item Pomična mjerila (klasična skala) Calipers (classical scale) range 0 mm 300 mm (rezolucija/resolution 0,02 mm) 0 mm 300 mm (rezolucija/resolution 0,05 mm) 0 mm 300 mm (rezolucija/resolution 0,1 mm) 1 and ( L) µm, L u/in m ( L) µm, L u/in m ( L) µm, L u/in m QP.5.4/03-LL izdanje/ Issue 02/03, Dužina Length Dužina Length Dužina Length lenjiri Measuring rulers Mjerne trake Measuring tapes Mjerne trake Measuring tapes 0 m do/to 3 m 0 m do/to 3 m Od 0 m do/to 200 m ( L) µm, L u/in m ( L) µm, L u/in m ( L) µm, L u/in m Metoda poređenja Comparison QP.5.4/06-LL izdanje/ Issue 01/02, Metoda poređenja Comparison QP.5.4/06-LL izdanje/ Issue 01/02, Metoda poređenja Comparison QP.5.4/06-LL Q a, izdanje /izmjena 1/2, datum: Strana: 11/30

12 7. 8. Dužina Length Dužina Length veličina/ predmet item Mjerne ure (satovi) (analogna skala) Dial gauges (analog scale) Mjerne ure (satovi) (digitalna skala) Dial gauges (digital scale) range 0 do/to100mm (rezolucija/resolution 0,01 mm) 0 do/to100mm (rezolucija/resolution 0,01 mm) 1 and (3 + 9 L) µm, L u/in m (6 + 9 L) µm, L u/in m izdanje/ Issue 01/02, Direktna Direct method QP.5.4/07-LL izdanje/ Issue 01/02, Direktna Direct method QP.5.4/07-LL izdanje/ Issue 01/02, Dužina Length Dužina Length Univerzalni mjerni uređaj 1D 1D Measuring instrument Unutrašnji prečnik 0 do/to 680 mm 8 do/to 150 mm (0,3 + 2,4 L) µm, L u/in m (0,7 + 1,4 D) µm, D u m Direktna Direct method QP.5.4/08-LL izdanje/ Issue 01/01, Direktna Q a, izdanje /izmjena 1/2, datum: Strana: 12/30

13 11. Dužina Length veličina/ predmet item Internal diametar Spoljašnji prečnik External diametar range 0,1 do/to 100 mm 1 and (0,7 + 0,8 D) µm, D u/in m Direct method QP.5.4/09-LL izdanje/ Issue 01/01, Direktna Direct method QP.5.4/10-LL izdanje/ Issue 01/01, Q a, izdanje /izmjena 1/2, datum: Strana: 13/30

14 Detaljan obim akreditacije/ Detailed scope of accreditation Laboratorija za električne veličine, Kralja Nikole 2, Podgorica * Metoda se sprovodi na terenu ** Metoda se sprovodi u Laboratoriji i na terenu veličina/ predmet item range 1 and 0 mv do/to 200 mv 5, U + 1 µv 1. Jednosmjer ni napon DC voltage Izvor napona, kalibrator,multi metar voltage source, calibrator, multimeter 200 mv do/to 2 V 3, U + 4 µv 2 V do/to 20 V 3, U + 40 µv 20 V do/to 200 V 5, U µv Vlastite procedure QP.5.4/01-LEQ 01/ QP.5.4/02-LEQ 01/ (EURAMET /cg-15/v.3.0, 02/2015) mjerenje + generiranje / measurement+ generating 200 V do/to 1000 V 5, U + 5 mv 2. Naizmjeničn i napon Izvor napona, 100 mv do/to 200 m V (50 Hz 100 khz) 7, U + 0,2 mv Vlastite procedure Q a, izdanje /izmjena 1/2, datum: Strana: 14/30

15 AC voltage veličina/ predmet item kalibrator,multi metar voltage source, calibrator, multimeter range 200 mv do/to 2 V (50 Hz 100 khz) 2 V do/to 20 V (50 Hz 100 khz) 20 V do/to 200 V (50 Hz 100 khz) 200 mv do/to 2 V (100 khz khz) 200 V do/to 700 V (50 Hz 1 khz) 1 and 5, U + 2 mv 5, U + 20 mv 5, U mv 0,1 U + 0,2 V 1, U + 0,2 V QP.5.4/01-LEQ 01/ QP.5.4/02-LEQ 01/ (EURAMET /cg-15/v.3.0, 02/2015) mjerenje + generiranje / measurement+ generating Jednosmjer na struja DC Current Naizmjeničn a struja AC Current Izvor jednosmjerne struje, kalibrator, ampermetar, multimetar DC Current source, calibrator, ampermeter, multimeter Izvor 0,1 ma do/to 0,2 ma 1, I + 4 na Vlastite procedure 0,2 ma do/to 2 ma 1, I + 40 na 2 ma do/to 20 ma 1, I + 0,4 µa QP.5.4/01-LEQ 01/05, QP.5.4/02-LEQ 20 ma do/to 200 ma 4, I + 8 µa 01/05, (EURAMET 200 ma do/to 2 A 1, I + 0,16 ma /cg- 15/v.3.0, 02/2015) 2 A do/to 10 A 4, I + 4 ma mjerenje + generiranje / measurement+ generating 0,1 ma do/to 0,2 ma 5, I + 0,2 μa Vlastite (50 Hz do 1 khz) procedure Q a, izdanje /izmjena 1/2, datum: Strana: 15/30

16 veličina/ predmet item naizmjenične struje, kalibrator, ampermetar, multimetar AC Current source, calibrator, ampermeter, multimeter range 0,2 ma do/to 2 ma (45 Hz do 10 khz) 2 ma do/to 20 ma (45 Hz do 10 khz) 20 ma do/to 200 ma (45 Hz do 10 khz) 200 ma do/to 2 A (45 Hz do 10 khz) 2 A do/to 10 A (45 Hz do 1 khz) 1 and 3, I + 2 μa 3, I + 20 μa 3, I μa 7, I + 2 ma 2, I + 20 ma QP.5.4/01-LEQ 01/05, QP.5.4/02-LEQ 01/05, (EURAMET /cg- 15/v.3.0, 02/2015) mjerenje + generiranje / measurement+ generating 5. Otpornost Resistance Otpornik, kalibrator, multimetar Resistor, calibrator, multimeter 1 Ω do/to 2 Ω 1, R + 40 μω Vlastite 2 Ω do/to 20 Ω 1, R + 0,15 mω 20Ω do/to 200Ω 8, R + 0,5 mω 200 Ω do/to 2 kω 8, R + 5 mω 2 kω do/to 20 kω 8, R + 50 mω 20 kω do/to 200 kω 8, R + 0,5 Ω 200 kω do/to 2 MΩ 9, R + 10 Ω 2 MΩ do/to 20 MΩ 2, R + 1 kω 20 MΩ do/to 100 MΩ 1, R kω procedure QP.5.4/01-LEQ 01/05, QP.5.4/02-LEQ 01/05, (EURAMET /cg- 15/v.3.0, 02/2015) 6. kliješta Measuring Jednosmjerni napon DC voltage 330 mv do/to 3,3 V U + 20 µv 3,3 V do/to 33 V U µv Q a, izdanje /izmjena 1/2, datum: Strana: 16/30

17 clamp kliješta Measuring clamp kliješta Measuring clamp kliješta Measuring clamp kliješta Measuring clamp veličina/ predmet item Naizmjenični napon AC voltage Jednosmjerna struja DCcurrent Naizmjenična struja AC current Otpornost Resistance range 33 V do/to 330 V 330 V do/to 1000 V 100 mv do/to 330 mv 45 Hz do/to 65 Hz 330 mv do/to 3,3 V 45 Hz do/to 65 Hz 3,3 V do/to 33 V 45 Hz do/to 65 Hz 33 V do/to 330 V 45 Hz do/to 65 Hz 330 V do/to 600 V 45 Hz do/to 65 Hz 1 and U + 1,5 mv U + 7,5 mv 3, U + 0,08 mv U +0,5 mv 3, U +6 mv 3, U + 60 mv U +100 mv 0,1 A do/to 10 A 0,05 I 10 A do/to 16,5 A 0,01 I + 0,05 A 16,5 A do/to 150 A 0,01 I + 0,5 A 150 A do/to 500 A 0,01 I + 1 A 0,1 A do/to 10 A 45 Hz do/to 65 Hz 0,05 I 10 A do/to 16,5 A 45 Hz do/to 65 Hz 0,01 I + 0,1 A 16,5 A do/to 150 A 45 Hz do/to 65 Hz 0,01 I + 0,5 A 150 A do/to 500 A 45 Hz do/to 65 Hz 0,01 I + 2 A 1Ω do/to 11 Ω R + 1 mω 11 Ω do/to 1,1 kω R + 2 mω 1,1 kω do/to 11 kω R + 20 mω 11 kω do/to 110 kω R + 0,2 Ω 110 kω do/to 1,1 MΩ R + 2 Ω 1,1 MΩ do/to 3,3 MΩ R + 30 Ω 3,3 MΩ do/to 11 MΩ 1, R + 50 Ω Q.P.5.4/03-LEQ 01/04, (EURAMET /cg- 15/v.3.0, 02/2015) Generiranje jednosmjernog napona/ Generating DC voltage Generiranje izmjeničnog napona/ Generating AC voltage Generiranje istosmjerne struje/ Generating DC current Generiranje izmjenične struje/ Generating AC current Q a, izdanje /izmjena 1/2, datum: Strana: 17/30

18 veličina/ predmet item range 1 and 11 MΩ do/to 40 MΩ R + 3 kω Q a, izdanje /izmjena 1/2, datum: Strana: 18/30

19 Detaljan obim akreditacije/ Detailed scope of accreditation Laboratorija za vrijeme i frekvenciju, Kralja Nikole 2, Podgorica * Metoda se sprovodi na terenu ** Metoda se sprovodi u Laboratoriji i na terenu veličina/predm et item range 1 and 1. Frekvencija Izvori frekvencije sources 1 mhz do/to 100kHz Hz QP.5.4/01-LTF 01/ mjerenje / measurement gate time = 100 s sinusni signal / sine wave 2. Frekvencija Izvori frekvencije sources 100 khz do/to 350 MHz f QP.5.4/01-LTF 01/ mjerenje / measurement gate time = 100 s sinusni signal / sine wave Q a, izdanje /izmjena 1/2, datum: Strana: 19/30

20 veličina/predm et item range 1 and 3. Frekvencija Izvori frekvencije sources 1 mhz do/to 1 Hz Hz QP.5.4/01-LTF 01/ mjerenje / measurement gate time = 100 s pravokutni signal / rectangular wave 4. Frekvencija Izvori frekvencije sources 1 Hz do/to 350 MHz f QP.5.4/01-LTF 01/ mjerenje / measurement gate time = 100 s pravokutni signal / rectangular wave 5. Frekvencija Izvori frekvencije sources 1 mhz do/to 100 khz Hz QP.5.4/04-LTF 01/ generiranje / generating sinusni signal / sine wave Q a, izdanje /izmjena 1/2, datum: Strana: 20/30

21 veličina/predm et item range 1 and 6. Frekvencija Izvori frekvencije sources 100 khz do/to 100 MHz f QP.5.4/04-LTF 01/ generiranje / generating sinusni signal / sine wave 7. Frekvencija Izvori frekvencije sources 1 mhz do/to 1 Hz Hz QP.5.4/04-LTF 01/ generiranje / generating pravokutni signal / rectangular wave 8. Frekvencija Izvori frekvencije sources 1 Hz do/to 100 MHz f QP.5.4/04-LTF 01/ generiranje / generating pravokutni signal / rectangular wave Q a, izdanje /izmjena 1/2, datum: Strana: 21/30

22 veličina/predm et item range 1 and Vremenski interval Time interval Vremenski interval Time interval Izvori vremenskog intervala Sources of the time interval Izvori vremenskog intervala Sources of the time interval 1 ns do/to s t + 0,5 ns 0,00 s/d do/to ±100 s/d 2,7 s/d QP.5.4/02-LTF 01/ mjerenje / measurement Ručni sekundomjeri - mjerenje odstupanja s/d Hand stopwatches - measurement of deviation s/d 11. Razlika vremenskih skala Time scale difference Etalon vremena Time standard -1 s do/to 1 s 10 ns In house pr QP.5.4/06-LTF 01/ Direktno mjerenje razlike 1 PPS signala mjerilom vremenskog intervala / Direct measurement of 1 PPS signal difference with time interval measuring instrument Q a, izdanje /izmjena 1/2, datum: Strana: 22/30

23 veličina/predm et item range 1 and 12. Razlika vremenskih skala Time scale difference Etalon vremena Time standard -1 s do/to 1 s 200 ns In house pr QP.5.4/06-LTF 01/ poređenje u odnosu na predviđeno UTC vrijeme / Comparison against predicted UTC time Q a, izdanje /izmjena 1/2, datum: Strana: 23/30

24 Detaljan obim akreditacije/ Detailed scope of accreditation Laboratorija za pritisak, Kralja Nikole 2, Podgorica * Metoda se sprovodi na terenu ** Metoda se sprovodi u Laboratoriji i na terenu veličina/ predmet item range 1 and 1. Pritisak Pressure Nadpritisak/ Elektromehanič ki manometri Gauge Pressure/ Electromechanic al manometers -0,95 bar do/to 1 bar gas 1 bar do/to 25 bar gas 6 bar do/to 1200 bar ulje/oil p+10 Pa p,ali ne manje/but not lower than 25 Pa p,ali ne manje/bat not lower than 1 mbar Vlastite procedure QP.5.4/01-LP 01/ i/and QP.5.4/02-LP 01/ i/and QP.5.4/03-LP 01/ i/and QP.5.4/04-LP 01/ EURAMET cg- 17/ v.3.0 (04/2017) Q a, izdanje /izmjena 1/2, datum: Strana: 24/30

25 veličina/ predmet item range 1 and 0 bar do/to 40 bar gas 0 bar do/to 700 bar voda/water 0,015 bar 0,035bar Vlastite procedure QP.5.4/03-LP 01/ ** i/and QP.5.4/04-LP 01/ ** EURAMET cg- 17/ v.3.0 (04/2017) 2. Pritisak Pressure Apsolutni pritisak/ Elektromehanič ki manometri Absolute Pressure/ Electromechanic al manometers 100 mbar do/to 750 mbar gas 750 mbar do/to 1150 mbar gas 1150 mbar do/to 2 bar gas p+15 Pa 15 Pa p+15 Pa QP.5.4/03-LP 01/ ** EURAMET cg- 17/ v.3.0 (04/2017) Q a, izdanje /izmjena 1/2, datum: Strana: 25/30

26 Detaljan obim akreditacije/ Detailed scope of accreditation Laboratorija za male zapremine, Kralja Nikole 2, Podgorica * Metoda se sprovodi na terenu ** Metoda se sprovodi u Laboratoriji i na terenu Zapremina Volume Zapremina Volume veličina/predm et item Zapremina/ Volumetrijske pipete Volume/ Single-volume pipettes Zapremina/ Graduirane mjerne pipete Volume/ Graduated measuring pipettes range V = 10 ml 1 and 0,005 ml 10 ml < V 25 ml 0,008 ml 25 ml < V 50 ml 0,011 ml 50 ml < V 100 ml 0,022 ml V = 10 ml 0,010 ml 10 ml < V 25 ml 0,018 ml Gravimetrijska Gravimetic method QP.5.4/01-LSV Izdanje / Issue (02/01) Gravimetrijska Gravimetic method QP.5.4/01-LSV Izdanje / Issue (02/01) Zapremina Volume Zapremina/ Birete Volume/ Burettes V = 10 ml 10 ml < V 25 ml 0,010 ml 0,012 ml Gravimetrijska Gravimetic method 25 ml < V 50 ml 0,016 ml 50 ml < V 100 ml 0,022 ml QP.5.4/01-LSV Izdanje / Issue (02/01) Q a, izdanje /izmjena 1/2, datum: Strana: 26/30

27 veličina/predm et item range 1 and Zapremina Volume Zapremina/ Graduirani mjerni cilindri Volume/ Graduated measuring cylinders V = 5 ml 0,010 ml 5 ml < V 10 ml 0,020 ml 10 ml < V 20 ml 0,040 ml 20 ml < V 25 ml 0,050 ml 25 ml < V 50ml 0,10 ml 50 ml < V 100 ml 0,17 ml 100 ml < V 250 ml 0,40 ml 250ml < V 500 ml 0,70 ml 500 ml < V ml 1,3 ml Gravimetrijska Gravimetic method QP.5.4/01-LSV Izdanje/ Issue (02/01) ml V 10 ml 0,006 ml 5. Zapremina Volume Zapremina/ Mjerne tikvice sa jednom mjernom crtom Volume/ One-mark volumetric flasks 10 ml < V 25 ml 0,010 ml 25 ml < V 50 ml 0,015 ml 50 ml < V 100 ml 0,022 ml 100 ml < V 250 ml 0,055 ml 250 ml < V 500 ml 0,11 ml 500 ml < V ml 0,22 ml ml < V 2000 ml 0,44 ml ml < V 5000 ml 1,1 ml Gravimetrijska Gravimetic method QP.5.4/01-LSV Izdanje/ Issue (02/01) Zapremina Volume Zapremina/ Pipete sa klipom Volume/ Piston pipettes V=1 µl 0,034 µl 1 µl < V 10 µl 0,04 µl 10 µl < V 25 µl 0,06 µl 25 µl < V 50 µl 0,12 µl 50 µl < V 100 µl 0,24 µl 100 µl < V 150 µl 0,4 µl Gravimetrijska Gravimetic method Q a, izdanje /izmjena 1/2, datum: Strana: 27/30

28 veličina/predm et item range 1 and 150 µl < V 250 µl 0,6 µl 250 µl < V 500 µl 1,2 µl QP.5.4/02-LSV 500 µl < V 1000 µl 2,4 µl Izdanje / Issue (02/01) 1000 µl < V 1250 µl 3 µl µl < V 2500 µl 6 µl 2500 µl < V 5000 µl 12 µl 5000 µl < V µl 24 µl 7. Zapremina Volume Zapremina/ Piknometri Volume/ Pycnometers V=1 ml 1 ml<v 10 ml 0,0025 ml 0,004 ml Gravimetrijska Gravimetic method 10 ml<v 25 ml 0,006 ml 25 ml<v 50 ml 0,010 ml QP.5.4/03-LSV Izdanje / Issue (02/01) 50 ml<v 100 ml 0,020 ml Q a, izdanje /izmjena 1/2, datum: Strana: 28/30

29 Detaljan obim akreditacije/ Detailed scope of accreditation Laboratorija za velike zapremine, Ul. 27. marta zgrada D9, Podgorica * Metoda se sprovodi na terenu ** Metoda se sprovodi u Laboratoriji i na terenu veličina/predm et item range 1 and Zapremina Volume Zapremina Volume Zapremina/ Etalon prelivne pipete od metala Volume/ Over flow pipettes Zapremina/ Mjerne posude od metala Volume/ Metal standard capacity measures 5 l 10 l 1,1 ml 2 ml Gravimetrijska Gravimetic method 50 l 10 ml 100 l 26 ml QP.5.4/01-LSV Izdanje / Issue (01/03) V = ml 0,40 ml ml <V ml 1 ml ml <V ml 2 ml ml <V ml 4 ml ml <V ml 10 ml ml <V ml 20 ml ml <V ml 40 ml ml <V ml 101 ml Gravimetrijska Gravimetic method QP.5.4/02-LLV Izdanje / Issue (01/03) Zapremina Volume Zapremina/ Mjerne posude od stakla Volume/ Glass standard V = ml 0,20 ml Gravimetrijska ml <V ml 0,40 ml Gravimetic ml <V ml 1 ml method ml <V ml 2 ml Q a, izdanje /izmjena 1/2, datum: Strana: 29/30

30 veličina/predm et item capacity measures range 1 and QP.5.4/02-LLV Izdanje / Issue (01/03) Zapremina Volume Zapremina/ Mjerne posude od metala Volume/ Metal standard capacity measures 5 l 2 ml 20 l 8 ml 50 l 20 ml 100 l 40 ml 200 l 80 ml 500 l 200 ml l 400 ml Volumetrijska Volumetric method QP.5.4/03-LLV Izdanje / Issue (01/03) CMC ( and ) je procijenjena kao proširena mjerna nesigurnost dobijena množenjem standardne nesigurnosti s faktorom pokrivanja k, koji odgovara nivou povjerenja od oko 95%. Uobičajeno je, i ako nije drugačije navedeno, faktor k iznosi 2. CMC je izračunata u skladu s EA 4/02 M:2013 Evaluation of the Uncertainty of measurement in. 1 The CMC ( and ) has been estimated as an expanded uncertainty obtained by multiplying the standard uncertainty by the coverage factor k corresponding to confidence level of about 95 %. rmally and unless stated otherwise, this factor k is 2. The CMC has been determined according to the EA 4/02 M:2013 Evaluation of the Uncertainty of measurement in. Ovаj obim vаži sаmo uz Sertifikаt o аkreditаciji sа аkreditаcionim brojem L K od This Scope of accreditation is valid only with the accreditation certificate L K issued on Direktor ATCG Milivoje Pavićević Q a, izdanje /izmjena 1/2, datum: Strana: 30/30

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for Accreditation (EA) Multilateral Agreement PRILOG POTVRDI O

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Palenque 1 A, Bello Horizonte,. (Hereinafter called

More information

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for Accreditation (EA) Multilateral Agreement PRILOG POTVRDI O

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Compania Nacional de Metrologia S.A.S - Conamet

More information

Scope of Accreditation For ISOLAB Inc. Calibration

Scope of Accreditation For ISOLAB Inc. Calibration Scope of Accreditation For ISOLAB Inc 6260 Hawthorne Dr Windsor, ON N8T 1J9 Pradip Jansari 519-948-8371 In recognition of a successful assessment to ISO/IEC 17025:2005 to the following and Measurement

More information

For the National Voluntary Laboratory Accreditation Program

For the National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 Additel Corporation 2900 Saturn Street Brea, CA 92821 Eric Chavier Phone: 714-998-6899 Fax: 714-998-6999 E-mail: eric.chavier@additel.com URL: http://additel.com

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Ciudad Madero, Tamaulipas, México. C.P. 89520 (Hereinafter

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Asesoría Industrial en Mantenimiento y Calibración

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Guadalupe, Nuevo León, México. C.P. 67110 (Hereinafter

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 EQUIPMENT SERVICES GROUP, LLC 3269 Hilton Rd. Ferndale, MI 48220 Michael Macauley Phone: 248 227 5310 CALIBRATION Valid To: December

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: AMC LABS S.A de C.V (Hereinafter called the Organization)

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ALLOMETRICS, INC Bayport Blvd. Seabrook, TX Terry Baldwin Phone: CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ALLOMETRICS, INC Bayport Blvd. Seabrook, TX Terry Baldwin Phone: CALIBRATION SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ALLOMETRICS, INC. 2500 Bayport Blvd. Seabrook, TX 77586 Terry Baldwin Phone: 281 474 3329 CALIBRATION Valid To: April 30, 2019 Certificate Number: 2039.01 In

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 AMERICAN INSTRUMENT CORPORATION Crossroads Centre 702 Rose Drive Hartland, WI 53029 Jeff Quinn Phone: 262 367 4409 CALIBRATION Valid

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Hards Laboratories cc, t/a Technology Solutions

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 PROTEMP MECHANICAL, INC. 3350 Scott Blvd, Bldg. #3 Santa Clara, CA 95054 Martin L. Reich Phone: 408 244 9821 CALIBRATION Valid To: August

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Laboratory locations: Schedule of Accreditation 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 1G Kilroot Business Park Carrickfergus Co Antrim BT38 7PR Contact: Mr R E Hughes Tel:

More information

For the National Voluntary Laboratory Accreditation Program

For the National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Navy Primary Standards Laboratory NAVAIR North Island Code 4.12.9 Bldg. 469S P.O. Box 357058 San Diego, CA 92135-7058 Mr. Al Teruel Phone: 619-545-7912 Fax

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL Lasheila Hayes Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL Lasheila Hayes Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL 35096 Lasheila Hayes Phone: 205 505 0296 CALIBRATION Valid to: April 30, 2019 Certificate Number:

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: C.V. (Calpromsa) (Hereinafter called the Organization)

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS 38654 CONNIE FOSTER PHONE: 800 327 7727 CALIBRATION Valid To: August 31, 2019 Certificate Number:

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. 705.00 Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc., has assessed the Laboratory of: (Hereinafter called the Organization) and

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: AMC LABS S.A de C.V Av. México # 329 Col. Valle De

More information

Interlaboratory Comparison & Proficiency Testing Program

Interlaboratory Comparison & Proficiency Testing Program Extended scope for the organization of proficiency tests in accordance with the requirements of ISO/IEC 17043 VSL, the Dutch Metrology Institute, has significantly extended the scope for their accreditation

More information

Certificate of Accreditation to ISO/IEC 17025:2005

Certificate of Accreditation to ISO/IEC 17025:2005 United States Department of Commerce National Institute of Standards and Technology Certificate of Accreditation to ISO/IEC 17025:2005 NVLAP LAB CODE: 200508-0 Insco Metrology, Inc. Miami, FL is accredited

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 JEM PRECISION 9615 56 Avenue NW Edmonton, Alberta T6E 0B2 Canada Robert Korthuis Phone: 780-440 1933 CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 RS CALIBRATION SERVICES, INC. 1047 Serpentine Lane Pleasanton, CA 94566 Mr. Ralph Sabiel Phone: 925 462 4217 CALIBRATION Valid To: April

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:. Av. Rio Consulado # 2614, Col. San Juan de Aragón

More information

Interlaboratory Comparison & Proficiency Testing Program

Interlaboratory Comparison & Proficiency Testing Program Extended scope for the organization of proficiency tests in accordance with the requirements of ISO/IEC 17043 VSL, the Dutch Metrology Institute, has significantly extended the scope for their accreditation

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: CONMED LABMET S. de R.L. de C.V. (Hereinafter called

More information

Interlaboratory Comparison & Proficiency Testing Program

Interlaboratory Comparison & Proficiency Testing Program Extended scope for the organization of proficiency tests in accordance with the requirements of ISO/IEC 17043 VSL, the Dutch Metrology Institute, has significantly extended the scope for their accreditation

More information

SERVICES OF DMDM I CALIBRATION MASS PRESSURE... 21

SERVICES OF DMDM I CALIBRATION MASS PRESSURE... 21 SERVICES OF DMDM I CALIBRATION... 2 1. MASS... 2 2. PRESSURE... 2 3. LENGHT & ANGLE... 3 4. ACOUSTICS... 4 5. TIME, FREQUENCY & VELOCITY... 5 6. VOLUME... 6 7. TEMPERATURE... 7 8. HUMIDITY... 9 9. ELECTIRICITY/DC

More information

For the National Voluntary Laboratory Accreditation Program

For the National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Navy Primary Standards Laboratory NAVAIR North Island Code 4.12.9 Bldg. 469S P.O. Box 357058 San Diego, CA 92135-7058 Mr. Al Teruel Phone: 619-545-7912 Fax

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ARCONIC POWER AND PROPULSION RESEARCH CENTER 1500 S. Warner St. Whitehall, MI 49461-1895 Michelle McDonald Phone: 231 894 7586 CALIBRATION

More information

OA07 ANNEX 4: SCOPE OF ACCREDITATION IN CALIBRATION

OA07 ANNEX 4: SCOPE OF ACCREDITATION IN CALIBRATION OA07 ANNEX 4: SCOPE OF ACCREDITATION IN CALIBRATION Table of contents 1 TECHNICAL FIELDS... 2 2 PRESENTING THE SCOPE OF A CALIBRATION LABOORATORY... 2 3 CONSIDERING CHANGES TO SCOPES... 6 4 CHANGES WITH

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Establishing traceability and estimating measurement uncertainty in physical, chemical and biological measurements

Establishing traceability and estimating measurement uncertainty in physical, chemical and biological measurements Establishing traceability and estimating measurement uncertainty in physical, chemical and biological measurements Experimental Design 8.2.2013 Doc. Martti Heinonen etunimi.sukunimi@mikes.fi Outline 1.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALABAMA SCALE & INSTRUMENT MARSHALL, INC. d.b.a. ASI Calibration Labs - Texas 1006 East End Blvd North Marshall, TX 75672 Lawson Hill

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:. (Hereinafter called the Organization) and hereby

More information

2. MASS AND VOLUME MEASUREMENTS Mass measurement Analytical and standard laboratory balances Pre-lab Exercises

2. MASS AND VOLUME MEASUREMENTS Mass measurement Analytical and standard laboratory balances Pre-lab Exercises Name:. Date: Objectives 2. MASS AND VOLUME MEASUREMENTS To overview the metric and SI units of mass and volume measurements. To introduce the laboratory equipment used for mass and volume measurements.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 FLORIDA METROLOGY, LLC 645 NW Enterprise Dr. Port St. Lucie FL 34986 Ron Kupper Phone: (772)212-7158 CALIBRATION Valid To: October 31,

More information

National Voluntary Laboratory Accreditation Program

National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Sapphire Technical Solutions, L.L.C. 10230 Rodney St. Pineville, NC 28134 Mr. Ron Wathan Phone: 704-561-3100 x106 Fax: 866-829-1502 E-mail: rwathan@sapphirests.com

More information

Automated volume measurement for weihts using acoustic volumeter

Automated volume measurement for weihts using acoustic volumeter IMEKO 20th TC3, 3rd TC16 and 1st TC22 International Conference Cultivating metrological knowledge 27th to 30th November, 2007. Merida, Mexico. Automated volume measurement for weihts using acoustic volumeter

More information

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement Publication Reference EA-10/11 EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical PURPOSE This document has been produced by EA as a means of giving advice for calibrating

More information

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard 92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 QAL-TEK ASSOCIATES 3998 Commerce Circle Idaho Falls, ID 83401 Travis Snowder Phone: 208 523 5557 CALIBRATION Valid To: January 31, 2019

More information

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard 92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1

More information

NAPREDNI FIZIČKI PRAKTIKUM 1 studij Matematika i fizika; smjer nastavnički MJERENJE MALIH OTPORA

NAPREDNI FIZIČKI PRAKTIKUM 1 studij Matematika i fizika; smjer nastavnički MJERENJE MALIH OTPORA NAPREDNI FIZIČKI PRAKTIKUM 1 studij Matematika i fizika; smjer nastavnički MJERENJE MALIH OTPORA studij Matematika i fizika; smjer nastavnički NFP 1 1 ZADACI 1. Mjerenjem geometrijskih dimenzija i otpora

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 POLYMER TESTING INSTRUMENTS, INC. 10 National Drive Fletcher, NC 28732 Larry Eisner Phone: 828 252 1326 CALIBRATION Valid To: June 30,

More information

BUREAU INTERNATIONAL DES POIDS ET MESURES

BUREAU INTERNATIONAL DES POIDS ET MESURES BUREAU INTERNATIONAL DES POIDS ET MESURES Bilateral comparison of 1 Ω and 10 kω standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the SMD (Belgium) and the BIPM October 2017 Final

More information

Mason Technology Ltd

Mason Technology Ltd Mason Technology Ltd 228 South Circular Road, Dublin 8 Calibration Laboratory Registration number: 043C is accredited by the Irish National Board (INAB) to undertake calibration as detailed in the Schedule

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 POLYMER TESTING INSTRUMENTS, INC. 74 Patton Ave. Asheville, NC 28801 Greg Skory Phone: 828 252 1326 CALIBRATION Valid To: June 30, 2017

More information

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and

More information

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

CALYS 80P. Field pressure calibrator with high accuracy 0.01% Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS

More information

Ackred. nr 1678 Kalibrering ISO/IEC 17025

Ackred. nr 1678 Kalibrering ISO/IEC 17025 Calibration Tvinnargatan 25 SE-507 30 Brämhult SWEDEN Phone: +4633 22 56 30 info@kalibrera.se www.kalibrera.se Ackred. nr 1678 Kalibrering ISO/IEC 17025 Our calibration lab is accredited by Swedac for:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CONTROL COMPANY 12554 Galveston Road Suite B230 Webster, TX 77598 Aaron Judice Phone: 281 482 1714 CALIBRATION Valid To: March 31, 2018

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Guide for volume determination within the scope of reference measurement procedures in medical reference measurement laboratories, Part 1

Guide for volume determination within the scope of reference measurement procedures in medical reference measurement laboratories, Part 1 Page 1 Translation of eitfaden für die Volumenbestimmung bei Referenzmessprozeduren in medizinischen Referenzlaboratorien, Teil 1: Kalibrierflüssigkeit Wasser, PTB-Mitteilungen 112 (2002) No. 2, pp.139-149

More information

Technical Procedure for Measurement Assurance

Technical Procedure for Measurement Assurance Technical Procedure for Measurement Assurance 1.0 Purpose - This procedure specifies the required elements for measurement assurance in the Drug Chemistry Sections of the State Crime Laboratory. 2.0 Scope

More information

Perry Johnson Laboratory Accreditation, Inc. Calibration Scopes of Accreditation

Perry Johnson Laboratory Accreditation, Inc. Calibration Scopes of Accreditation Perry Johnson Laboratory Accreditation, Inc. Calibration Scopes of Accreditation PL-4 Calibration Scopes Revised: 2/17 Page 1 of 19 1.0 INTRODUCTION 1.1 This policy has been developed by PJLA and its technical

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 A.A. JANSSON Inc. 2070 Airport Road Waterford, MI 48327-1204 Justin Frazzini Phone: 248 674 4811 CALIBRATION Valid To: August 31, 2016

More information

BUREAU INTERNATIONAL DES POIDS ET MESURES

BUREAU INTERNATIONAL DES POIDS ET MESURES BUREAU INTERNATIONAL DES POIDS ET MESURES Bilateral comparison of 1 Ω and 10 kω standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NIMT (Thailand) and the BIPM December 016 Final

More information

Calibration of Volumetric Glassware. Prepared by Allan Fraser May 2016 APPLICATION Note 1

Calibration of Volumetric Glassware. Prepared by Allan Fraser May 2016 APPLICATION Note 1 Calibration of Volumetric Glassware Prepared by Allan Fraser May 2016 APPLICATION Note 1 TABLE OF CONTENTS TABLE OF CONTENTS... i LIST OF TABLES... ii 1. 2. 3. 4. 5. 6. 7. 8. Purpose... 1 Scope... 1 Principle...

More information

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006% ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX

More information

INTRODUCTION TO MEASUREMENTS

INTRODUCTION TO MEASUREMENTS INTRODUCTION TO MEASUREMENTS Introduction: In the first three experiments you will learn how to use equipment that to measure length, mass, and volume. You will apply the rules about significant figures

More information

Mason Technology Ltd

Mason Technology Ltd Mason Technology Ltd 228 South Circular Road, Dublin 8 Calibration Laboratory Registration number: 043C is accredited by the Irish National Board (INAB) to undertake calibration as detailed in the Schedule

More information

CERTIFICATE OF CALIBRATION

CERTIFICATE OF CALIBRATION Page 1 of 5 CERTIFICATE OF CALIBRATION 1K Thermistor CERTIFICATE NO.: MANUFACTURER: Measurement Specialties DATE OF CALIBRATION: 26-Apr-17 TC15249 CUSTOMER: AMBIENT TEMPERATURE: (21 ± 3) C JOB NUMBER:

More information

INTERNATIONAL COMPARISON OF PLATINUM RESISTANCE THERMOMETERS BETWEEN CHILE AND ECUADOR

INTERNATIONAL COMPARISON OF PLATINUM RESISTANCE THERMOMETERS BETWEEN CHILE AND ECUADOR INTERNATIONAL COMPARISON OF PLATINUM RESISTANCE THERMOMETERS BETWEEN CHILE AND ECUADOR M. Araya 1, D. Almeida 2 1 National Laboratory of Temperature of Chile, LCPNT, Santiago, Chile 2 Ecuadorian Standardization

More information

SAMPLE. Accuracy Calibration Certificate. Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC ISO17025 WI v.1.0

SAMPLE. Accuracy Calibration Certificate. Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC ISO17025 WI v.1.0 076-0-067-ACC-USL-S Mettler Toledo, LLC 900 Polaris Parkway Columbus, OH 0.800.METTLER Customer Accredited by the American Association for Laboratory Accreditation (ALA) CALIBRATION CERT #788.0 SAMPLE

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

2.1. Accuracy, n- how close the indication of the thermometer is to the true value. AASHTO Accreditation Policy and Guidance on Thermometer Selection and Records Revised: January 25, 2018 Revision #: 0 1. Objective 1.1. The purpose of this document is to clearly define acceptance criteria

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 QUALITY PLUS, INC. 170 Grove Street Chicopee, MA 01020 Mark J. Vickers Phone: 413 594 5529 CALIBRATION Valid

More information

Calibration of Temperature Block Calibrators

Calibration of Temperature Block Calibrators European Association of National Metrology Institutes Calibration of Temperature Block Calibrators EURAMET cg-13 Version 2.0 (03/2011) Previously EA-10/13 Calibration Guide EURAMET cg-13 Version 2.0 (03/2011)

More information

OA03 UNCERTAINTY OF MEASUREMENT IN CHEMICAL TESTING IN ACCORDANCE WITH THE STANDARD SIST EN ISO/IEC Table of contents

OA03 UNCERTAINTY OF MEASUREMENT IN CHEMICAL TESTING IN ACCORDANCE WITH THE STANDARD SIST EN ISO/IEC Table of contents UNCERTAINTY OF MEASUREMENT IN CHEMICAL TESTING IN ACCORDANCE WITH THE STANDARD SIST EN ISO/IEC 17025 Table of contents 1 GENERAL... 2 2 THE STANDARD SIST EN ISO/IEC 17025... 2 3 SA'S POLICY IN IMPLEMENTING

More information

Physikalisch- Technische Bundesanstalt

Physikalisch- Technische Bundesanstalt Physikalisch- Technische Bundesanstalt Guideline Calibration of Multiple Delivery Dispensers Edition 01/2018 Page: 2 / 22 Deutscher Kalibrierdienst (DKD) German Calibration Service Since its foundation

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Wiltonstraat 25 3905 KW Veenendaal The Netherlands Location(s) where activities are performed under accreditation Head Office Location Abbreviation/ location Main Location Wiltonstraat 25 3905 KW Veenendaal

More information

SAMPLE. Accuracy Calibration Certificate. Mettler Toledo 1900 Polaris Parkway Contact: Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC WI v.1.

SAMPLE. Accuracy Calibration Certificate. Mettler Toledo 1900 Polaris Parkway Contact: Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC WI v.1. 076-00-067-ACC-S Mettler Toledo, LLC 900 Polaris Parkway Columbus, OH 0.800.METTLER Customer SAMPLE Accuracy Calibration Certificate Company: Address: City: Zip / Postal: State / Province: Mettler Toledo

More information

Accuracy Calibration Certificate

Accuracy Calibration Certificate gl06-0-067-acc Mettler Toledo Service Business Unit Industrial 900 Polaris Parkway Columbus, OH 0-800-- Services Provided By: Customer Accuracy Calibration Certificate Company: Sample Company Test Address:

More information

Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018

Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018 Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018 Guidelines on the Calibration of Automatic Instruments for

More information

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-K-15133-02-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 24.01.2018 to 23.01.2023 Holder of certificate: Hexagon

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CLEVELAND SPECIALTY INSPECTION SERVICES, INC. 8562 East Avenue Mentor, OH 44060 James Popovic Phone: 440 974 1818 CALIBRATION Valid

More information

Why the fuss about measurements and precision?

Why the fuss about measurements and precision? Introduction In this tutorial you will learn the definitions, rules and techniques needed to record measurements in the laboratory to the proper precision (significant figures). You should also develop

More information

Mass Mass is the amount of matter in an object. SI unit: kilogram (kg) 1 kg = 1000 g 1 g = 1000 mg. An adult brain: 1.3 ~1.4 kg

Mass Mass is the amount of matter in an object. SI unit: kilogram (kg) 1 kg = 1000 g 1 g = 1000 mg. An adult brain: 1.3 ~1.4 kg Mass Mass is the amount of matter in an object. SI unit: kilogram (kg) 1 kg = 1000 g 1 g = 1000 mg An adult brain: 1.3 ~1.4 kg Beam Balance and Electronic Balance Beam balance and electronic balance are

More information

Training Benefits Adding Values to Your Systems/ Organization through: Potential Attendees These Courses have been designed for;

Training Benefits Adding Values to Your Systems/ Organization through: Potential Attendees These Courses have been designed for; Potential Attendees These Courses have been designed for; Calibration engineers and Technicians. Training Benefits Adding Values to Your Systems/ Organization through: Planning Engineers and decision makers.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ALPHAGAGE th Avenue Rockford, IL James Hoard Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ALPHAGAGE th Avenue Rockford, IL James Hoard Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALPHAGAGE 5245 27 th Avenue Rockford, IL 61109 James Hoard Phone: 815 391 6400 CALIBRATION Valid To: August 31, 2018 Certificate Number:

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

CERTIFICATE OF CALIBRATION

CERTIFICATE OF CALIBRATION Page 1 of 10 CALIBRATION OF Sound Level Meter: Brüel & Kjær Type 3050-A-040 No: 3050-100751 Id: - Microphone: Brüel & Kjær Type 4189 No: 2621142 Preamplifier: Brüel & Kjær Type 2669 No: 2679073 Supplied

More information

EA-10/13. EA Guidelines on the Calibration of Temperature Block Calibrators. Publication Reference PURPOSE

EA-10/13. EA Guidelines on the Calibration of Temperature Block Calibrators. Publication Reference PURPOSE Publication Reference EA-10/13 EA Guidelines on the Calibration of Temperature Block Calibrators PURPOSE This document been produced by EA to improve the harmonisation in the calibration of temperature

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 FRANK COX METROLOGY (Formerly CANADIAN CENTRAL GAUGE LABORATORY) 40 West Drive Brampton, Ontario, Canada L6T 3T6 Hilliard Cox Phone: 905 457 9190 CALIBRATION

More information

EXPERIMENT 30A1: MEASUREMENTS. Learning Outcomes. Introduction. Experimental Value - True Value. 100 True Value

EXPERIMENT 30A1: MEASUREMENTS. Learning Outcomes. Introduction. Experimental Value - True Value. 100 True Value 1 Learning Outcomes EXPERIMENT 30A1: MEASUREMENTS Upon completion of this lab, the student will be able to: 1) Use various common laboratory measurement tools such as graduated cylinders, volumetric flask,

More information

Final Report August 2010

Final Report August 2010 Bilateral Comparison of 100 pf Capacitance Standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the CMI, Czech Republic and the BIPM, January-July 2009 J. Streit** and N. Fletcher* *Bureau International

More information

All part numbers in the coding below start with "TC-" and end with "203"

All part numbers in the coding below start with TC- and end with 203 1. Scope: This specification for approval relates to 2. Type designation: The type designation shall be in the following form : All part numbers in the coding below start with "TC-" and end with "203"

More information

Euramet EM-S40. Bilateral Comparison KIM-LIPI / LNE. Final Report

Euramet EM-S40. Bilateral Comparison KIM-LIPI / LNE. Final Report DC resistance 1 mω, 100 Ω and 100 MΩ Bilateral Comparison KIM-LIPI / LNE Final Report Isabelle BLANC Laboratoire national de métrologie et d essais (LNE) 9 avenue Roger Hennequin F-78190 Trappes (France)

More information

Portuguese Institute for Quality. Contents

Portuguese Institute for Quality. Contents Instituto Português da PORTUGUESE INSTITUTE FOR QUALITY ualidade Final Report Bilateral comparison of a 500 µl micropipette EUROMET Project no. 1004 IPQ Coordinator of the comparison Elsa Batista September

More information

5.5. Calibration and Test Procedures

5.5. Calibration and Test Procedures 5.5. Calibration and Test Procedures - List of Calibration Procedures 1. C-18-010-2000, Calibration procedure of melting point measuring apparatus 2. C-18-011-2000, Calibration procedure of calorimeter

More information

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012 Revision 1.2 October 15, 2012 PAGE II TABLE OF CONTENTS TABLE OF CONTENTS... 1 GUIDANCE...2 1.0 Introduction... 2 2.0 Uncertainty and Traceability... 2 3.0 Need for Traceability... 3 3.1 What does traceability

More information

LAB 15. Traceability: Volumetric Apparatus. Edition 3 February 2019 Draft for Consultation. LAB 15 / Issue: 3 Page 1 of 12

LAB 15. Traceability: Volumetric Apparatus. Edition 3 February 2019 Draft for Consultation. LAB 15 / Issue: 3 Page 1 of 12 LAB 15 Edition 3 February 2019 Draft for Consultation LAB 15 / Issue: 3 Page 1 of 12 Contents 1. Introduction 3 2. Glassware / Plasticware 3 2.1 Scope 3 2.2 Classification of Volumetric Glassware 3 2.3

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 FRANK COX METROLOGY (Formerly CANADIAN CENTRAL GAUGE LABORATORY) 40 West Drive Brampton, Ontario, Canada L6T 3T6 Hilliard Cox Phone: 905 457 9190 CALIBRATION

More information