NECESSARY SEPARATION DISTANCES FOR LIGHTNING PROTECTION SYSTEMS - IEC REVISITED

Size: px
Start display at page:

Download "NECESSARY SEPARATION DISTANCES FOR LIGHTNING PROTECTION SYSTEMS - IEC REVISITED"

Transcription

1 X International Symposium on Lightning Protection 9 th -13 th November, 29 Curitiba, Brazil NECESSARY SEPARATION DISTANCES FOR LIGHTNING PROTECTION SYSTEMS - IEC REVISITED Fridolin H. Heidler 1, Wolfgang J. Zischank 2 1 University of Federal Armed Forces, Munich, Germany fridolin.heidler@unibw.de 2 University of Federal Armed Forces, Munich, Germany wolfgang.zischank@unibw.de Abstract - In case of direct lightning strike to a building dangerous sparking may occur between the external lightning protection system and conductive installations inside the building. To avoid such side flashes a minimum separation distance between conductive parts inside the building and the air termination or down system is required. The standard IEC provides formulae to determine the necessary separation distance. Objective of the paper is to re-visit the determination of separation distances. The international standard IEC recommends using electrically conductive parts of a building or structure as so-called natural components of the lightning protection system. The use of such extended metal parts can lead to significant reduction of the necessary separation distances. Objective of the paper is also to study the necessary separation distances for buildings using metal roofs, walls or attics as integral part of the lightning protection system. Such configurations are not yet covered by the IEC-standards. 1 INTRODUCTION According to the standard IEC 6235 part 1 [1] and part 2 [2] the lightning protection system (LPS) consists of the external and the internal LPS. Components of the external LPS are the air termination system, the down system and the earth termination system. The functions of the external LPS are to intercept the lightning flash, to conduct the lightning current safely to earth and to disperse it into the ground. In case of direct lightning strike, dangerous sparking may occur between the external LPS and metal installations inside the building. The function of the internal lightning protection is to prevent such dangerous sparking either by lightning equipotential bonding or by keeping the separation distance. The separation distance is the minimum clearance required at the proximity of conductive parts inside the building and the external LPS to avoid side flashes. According to the standard IEC [2] the necessary separation distance is given by the following equation kc s = ki l (1) k m The induction coefficient k i takes into account the highest voltage expected at the proximity considering the behaviour of the dielectric strength of air for sub-microsecond impulse voltages [3, 4]. With the steepness (di/dt) of the lightning current, the induced voltage is given by u = M ( di / dt) (2) The mutual inductance M is given by the structure resulting from the wiring of the external LPS and of installations inside the building. Because the subsequent strokes have much higher current steepness than the first strokes, in IEC [2] only the subsequent strokes are considered as short stroke current with the waveform.25/1 μs (front time T 1 =.25 μs, decay time to half value T 2 =.25 μs) [1]. Four lightning protection levels (LPL) are defined, the highest level being LPL I and the lowest level LPL IV. According to that classification, the current peak (5 ka) is highest for LPL I and reduced to 37,5 ka for LPL II and to 25 ka for LPL III and LPL IV. With the reduction of the current amplitude, the average front steepness i max /T 1 is lowered from 2 ka/μs for LPL I to 15 ka/μs for LPL II and to 1 ka/μs for LPL III/IV, seen in Table 1. 91

2 Corresponding to the four lightning protection levels, in IEC [2] four classes of LPS (I, II, III, IV) are defined. In the highest class of LPS I the induction coefficient is fixed to k i =,8 and reduced to k i =,6 and k i =,4 for LPS II and LPS III/IV considering the reduction of the current steepness (see Table 1). The configuration coefficient k c takes into account the percental current share to the individual down s being the same for all classes of LPS. Fig. 1 visualizes the configuration coefficient k c for three basic arrangements. The arrangements apply for simple structures with earth termination systems consisting of horizontal or vertical earth electrodes [2]. For a direct strike to a Franklin rod, the total current flows through that rod and thus the configuration coefficient results in k c = 1 (Fig. 1a). For the 2-dimensional arrangement in Fig. 1b, approximately 66 % of the lightning current flows through the outer down. That current share gives the value k c =,66. For the 3- dimensional arrangement in Fig. 1c, the fraction of current flowing through the corner down becomes about 44 % resulting in k c =,44. Table 1: Peak current i max, average front steepness i max /T 1 of the subsequent short stroke [1] and the configuration coefficient k i [2] LPL/LPS i max i max /T 1 k i I 5 ka 2 ka/μs,8 II 37,5 ka 15 ka/μs,6 III and IV 25 ka 1 ka/μs,4 a) Franklin rod i o (t) s metallic/electric installation down i o (t) l k c = 1 b) i o (t) air termination wire outer down s w,66 i o (t) l down w k c =,66 c) air termination mesh corner down,44 i o (t) s i o (t) w l down down w k c =,44 Fig. 1 Separation distance s and coefficient k c (a) Franklin rod (1-dimensional) (b) Air termination wire with down s (2-dimensional) (c) Meshed air termination and down system (3-dimensional) 92

3 For 3-dimensional grid-like structures using ring earth electrodes or foundation earth electrodes, in IEC annex C [2] the following formula is given k c 1 2 n c h = +,1 +,2 3 (3) with the spacing between the down-s c, the total number of down-s n and the height of structure h. The coefficient k m finally considers the dielectric strength of materials other than air present at the location of the proximity. Table 2 contains the values of the coefficient k m. For air k m = 1 applies. For construction materials (e.g. brick) this coefficient is reduced to the half. Table 2: Values of the coefficient k m. Material k m Air 1 Concrete, bricks,5 2 MOTIVATION TO REVISIT IEC Originally, Eq. (1) was developed using the vertical distance between the point, where the separation distance is to be considered, to the nearest equipotential bonding point for the length l. Meanwhile the length has been re-defined in the IEC standard as the total length along the air termination and the down s from the point, where the separation distance is to be considered to the nearest equipotential bonding point. The formula for k c later on was refined taking into account the height of the structure and the distance between the down s [2]. Furthermore, the original values of k i were reduced by 2 %. The k i -values (see Table 1) were originally fixed to,1 for LPS I, to,75 for LPS II and to,5 for LPS III and LPS IV [5]. Eq. (1) and the values for the parameters are based on calculations published in the mid 198s [3]. Due to the limited computer capacity available at that time, the modeling was limited to simple one-, two-, and three dimensional (cubic) lightning protection systems consisting of only stretched wires. Objective of the paper is to test the IEC equation for separation distances with state of the art computer codes solving the complete Maxwell equations. The international standard IEC [2] further recommends using electrically conductive parts of a building or structure as so-called natural components of the lightning protection system. Suited as natural components of the air termination and down system are e.g. the reinforcement of concrete, metal roofs, metal facades or attics as long as they are electrically continuously interconnected and provide a sufficient cross sectional area to conduct the lightning current without undue heating. The use of such extended metal parts as natural components of the lightning protection system can result in a significant reduction of the necessary separation distances between conductive parts inside the building and the air termination or down system. However, formulae to determine the necessary separation distance for such natural components are not yet contained in the IEC 6235 standard series. In this paper the influence of metal roofs, metal facades and attics on the separation distance is studied. The calculations were performed with the software CONCEPT II, which solves the Maxwell equations in the frequency domain using the method of moments (MoM). Exemplarily, the structures studied were all equipped with a lightning protection system according to class II of IEC [2]. The dimensions of the structures were varied in a wide range. In each case the induced voltages were calculated for three different points of strike on the roof and for two different induction s inside the structure. From the induced voltages the necessary separation distances were determined using the constant-area-criterion. 93

4 3 CONSTANT-AREA-CRITERION Fig. 2 shows the spark-over behavior of an air gap when exposed to impulse voltages of different steepness. The static onset voltage U o is the threshold below which no spark-over occurs. The voltage-time characteristic shows that the dielectric strength is a function of the voltage waveshape. For fast rising voltages, the air gap sparks over at higher voltage levels than U o. That behaviour is addressed to the fact that a certain period of time is needed to built up the arc between the electrodes of the air gap. The time characteristic of the dielectric strength is taken into account by the well established constant-area-criterion [6]. For unipolar impulse voltages of arbitrary wave shape the following equation applies: t 2 [ u(t) U ] dt = A (4) t1 The definitions used in Eq. (4) are illustrated in Fig. 3. The voltage-time area A is a constant value for a particular air gap. If the air gap is altered by varying the distance s between the electrodes, both the static onset voltage U o and the voltage-time area A are changed. For rod-rod gaps exposed to negative impulse voltages the following values apply [7]: U o s =,63 (5) [ MV ] [ m] A s =,59 (6) [ Vs] [ m] Eqs. (4 6) are used to evaluate the separation distance s between the wiring of the electrical installations inside the building and the external LPS. u(t) u Voltage-time characteristic of an air gap A U o U o t Fig. 2 Spark-over behavior of an air gap stressed by impulse voltages with different steepness t t 1 t2 Fig. 3 Illustration of the constant-area-criterion 4 COMPUTATIONAL APPROACH The fast rising current of the subsequent stroke induces very short voltage impulses in the considered installation s. Fig. 4 gives two examples of the induced voltage waveshapes: Almost any waveshape may occur, from a dominant peak at the beginning followed by only minor oscillations up to only slightly damped oscillations. The oscillations originate from the resonant effects of the considered. The resonances are due to the fact, that the dimensions are not small enough compared to the corresponding wave lengths of the fast rising current. These resonance effects are not covered by the simple formula of Eq. (2). 94

5 More precise computation of the voltage requires the solution of the complete Maxwell s equations. Therefore, the electromagnetic computations are carried out using the computer code CONCEPT, which has been developed during the last two decades by the Technical University Hamburg-Harburg [8]. This computer code is based on the so-called Method of Moments (MOM) [9] and is written in FORTRAN 77. It is a well-known computer code in the area of electromagnetic computations, and has been validated by several tests [8,1]. This computer code solves the complete Maxwell s equations in the frequency domain. Therefore, the time-domain solutions of currents and voltages are obtained from the inverse Fourier transformation. The fundamental assumptions of the computer code are given in [8,11] and the handling of the program package is described in [11]. 2 1,5 (MV) 1,5 u -,5 (a) 1,5 (MV) 1,5 u -,5,5 1 1,5 2 t (µs) -1 (b),5 1 1,5 2 t (µs) Fig. 4 Examples of voltage shapes induced by the subsequent return stroke current (waveform.25/1μs) (a) LPS type a (Fig. 6), Air termination: mesh, Point of strike: corner, Induction: Corner (b) LPS type b (Fig. 7 ), Air termination: metal roof, Point of strike: center, Induction: Center wire In the computer code CONCEPT, the return stroke process is simulated with the transmission-line (TL)-model introduced by Uman [12]. Using this model, the return stroke channel is assumed to be straight and perpendicular to the earth surface. The return stroke channel is considered to increase along the z-coordinate with the constant return stroke velocity chosen to v = 1 m/s. The TL-model only describes the interferences due to the return stroke process. This involves that the coupling of the lightning channel to the structure under study is taken into account, while the coupling from the structure back to the lightning channel is ignored. The TL model uses a pre-defined current source i B (t) at the channel-base, from where the time-varying current waveform propagates upwards in z-direction (Fig. 5). The current along the lightning channel as a function of time t and coordinate z is given by i( z, t) = ib( t z / v) (7) i(z,t) v z Lightning channel i B (t) striking point Fig. 5 Propagation of the lightning current along the return stroke channel according to the TL-model 95

6 This behavior is transferred to the frequency domain using the time shifting theorem of the Fourier analysis. The propagation of the current wave is simulated by means of the following equation z jω v I( z) = Î B e (8) Î(z) denotes the current on the lightning channel at the coordinate z and Î B is the channel-base current [13]. According to the IEC standard [1], the channel-base current i B (t) of subsequent stroke is simulated with a front time of T 1 = 25 ns. The following channel-base current it considered in the paper: ib / ib ( t) = T1 ib / max max t,, for for t T1 t T 1 (9) Eq. (9) defines a lightning current with a constant steepness during the current rise. After the current rise the current is kept constant at the peak value i B/max. The so-called thin wire approach is used to simulate the cylindrical s. The cylindrical s of the air termination system and of the down system are taken into account with the radius of 4 mm and with the conductivity of 56,2 1 6 S/m. These values are typical for an external lightning protection system consisting of copper. Metal sheets are simulated by rectangular and triangular patches assumed as ideal s. The segmentation of the patches can be seen in the Figs The ground is considered as plane also with ideal conductivity. Isolating materials other than air are disregarded (k m = 1). Three different frequency regimes are chosen in order to minimize the number of frequencies. Starting with a lowest frequency of 1 khz, the frequency is increased in steps of Δf = 2 khz up to 99 khz. Then in the second frequency regime, the frequency step is increased to Δf = 3 khz up to 2 MHz. In the highest frequency regime between 2 MHz and 2 MHz, the frequency step is further increased to Δf = 4 khz. As a general rule, the dimensions of the wires and of the patches should not exceed about λ/8, where λ is the wavelength of the highest frequency considered. In the paper, the highest considered frequency of 2 MHz corresponds to the wavelength of 15 m. Consequently, the wires and patches were subdivided into segments with maximum dimensions of 2 m. 5 EXAMINED STRUCTURES Various structures simulating the dimensions of typical buildings were selected for this study. Four structures had a base area of 2 m x 2 m with different heights of 1 m, 2 m, 4 m and 6 m, seen in Figs Further, a fifth structure with a large base area of 6 m x 6 m and a height of 1 m was included, seen in Figs. 11,12 [14,15]. The mesh size of the wire air termination system was 1 m x 1 m and the interspacing between the down s was 1 m, corresponding to a LPS of class II in IEC [2]. Whenever applicable, ring s, horizontally interconnecting the down s, were installed every 1 m of structure height. Four basic types of lightning protection systems (LPS) were considered for these five structures, as shown in Table 3. The LPS type a comprises stretched wires used for the air termination and the down s, as shown in Fig. 6. Fig. 7 and Fig. 8 show the LPS of the types b and c. Compared to the LPS of the type a, in the LPS of the types b and c the stretched wires are substituted by flat metal plates in order to simulate the metal roof and the metal walls, respectively. LPS type d shown in Fig. 9 considers the typical case of a circumferential metal attic at the roof. Three different lightning attachment points are considered, as shown in the Figs. 6-9: to the corner of the roof, to the middle of the roof side and to the center of the roof. In the following, they are denoted as corner strike, side strike and center strike. For calculation purposes, at these locations short lightning rods of 1 m length are placed and connected to the air termination system. The vertical lightning channel is attached to the tops of the rods. The channel-base current is injected at these attachment points corresponding to the TL-model (see Fig. 5). According to LPL II of IEC [1] the peak value of a subsequent stroke is i B/max = 37,5 ka, the front time being T 1 = 25 ns (see Table 1). 96

7 For the evaluation of the necessary separation distances two induction s were installed inside each structure. They are denoted as corner and center wire and shown as dashed lines in the Figs The corner starts from the roof corner of the structure with a 1 m long horizontal section pointing diagonally to the center. Following, a vertical section leads to ground. Of course, in case of the metal roof the horizontal section is missing. The center wire connects the air termination system and ground vertically in the center of the structure. Each is loaded by a high resistance of 1 MΩ in order to simulate open conditions at the proximity between the lightning protection system and internal conductive parts. Type of LPS Table 3: Types of lightning protection systems Air termination Down s a meshed wires wires b metal roof wires c meshed wires metal walls d meshed wires with metal attic Wires corner strike side strike corner strike center strike side strike corner center wire corner center wire Fig. 6 LPS type a Fig. 7 LPS type b corner strike corner center strike side strike corner strike side strike center strike corner center wire Fig. 8 LPS type c Fig. 9 LPS type d 97

8 6 CURRENTS 6.1 Current distribution to the down s The share of the injected current to the down s is determined for the asymmetric case of a lightning strike to the corner of the roof. Of special interest is the current through the corner down located directly beneath the point of strike: The ratio of the peak current through this down, i 1/max, to the peak of the incident lightning current, i B/max, equals to the parameter k c of Eq. (1). Table 4 gives the ratios of the corner down peak current i 1/max to the incident lightning current peak i B/max for the meshed air termination system (LPS type a ) and the flat metal roof (LPS type b ). In comparison to the meshed wire air termination also the values of k c according to Eq. (3) are listed in Table 4. In case of the structures with meshed air termination systems the values for k c according to IEC are in good agreement to the values calculated, the maximum deviation being 18 % in case of the large 6 m x 6 m structure. Fig. 1 shows the percentage current share p = i n/max / i B/max to the down s for the large 6 m x 6 m base structure. The numbering n of the down s can be seen from Figs. 11 and 12. Table 4: Ratio of the corner down current to the incident lightning current for strikes to the corner Structure size i 1/max / i B/max Meshed wire k c acc. to Eq. (3) flat metal roof x 1m,4,36,25 x 2m,33,32,22 6m x 6m x 1m,39,32,22 p [%] b a n Fig. 1 Percentage current distribution to the down s for the 6 m x 6 m x 1 m structure in case of corner strike. a) LPS type a with meshed air termination b) LPS typ b with flat metal roof Corner strike Side strike Center strike Meshed air termination system Corner strike Side strike Center strike Flat metal roof Corner 4 5 Center wire Down Corner Down s Fig. 11 LPS type a (6 m x 6 m x 1 m) with meshed air termination system of 1 m x 1 m mesh size and down s with 1 m interspacing Fig. 12 LPS typ b (6 m x 6 m x 1 m) with metal roof and down s with 1 m interspacing 98

9 Obviously, the down at the corner and its immediate neighbours carry the bulk of the current, while the rest of the down diverts only 5 % or less of the incident lightning current to ground. It should be noted that also in the case of the metal roof a remarkable part of the incident current flows through the corner down (about 22 %), although it is clearly less compared to the case of a meshed wire air termination (about 4 %). 6.2 Influence of the lightning current waveform For comparison, calculations were also performed using lightning current waveforms other than the linear rise according to Eq. (9). In these cases, the injected negative subsequent stroke (i B/max = 37,5 ka, T 1 = 25 ns) was simulated using the standardized lightning waveform of IEC annex B [1] given with Eq. (1) as well as a double exponential current waveform given with (11): i ( t) B B i ( t) i ( t / τ ) 1 = B / max 1 t / τ 2 e 1 η 1 + ( t / τ1), with τ 1 =.454 μs, τ 2 = 143 μs and η =.993 (1) i t / τ1 t / τ 2 ( e e ) B / max =, with τ 1 =.92 μs, τ 2 = 143 μs and η =.995 (11) η The comparison was performed for the x 1m LPS typ a structure and with lightning current injection to the roof corner. The maximum voltages induced to the corner are quite similar for the linear rising current waveform of Eq. (9) and the IEC current given in Eq. (1). Differences here are less than 25 %. Compared to the linear rising current waveform, the double exponential current waveform given by Eq. (11), however, produces maximum voltages about twice as high. This is due to the significantly higher maximum current steepness at t = inherent to a double exponential current waveform. 7.1 LPS type a consisting only of stretched wires 7 INDUCED VOLTAGE AND SEPARATION DISTANCE Table 5 contains the peak values of the induced voltages for the five examined structures of LPS type a consisting of only stretched wires. The corresponding separation distances are summarized in Table 6 for air (k m = 1). For all structures the corner strike represents the worst case, because it produces the highest peak values of the induced voltage in the corner. On the other hand, the induced voltages in the center wire are also very high in case of the center strike. Table 5: Induced voltages for LPS type a (k m = 1) Structure Peak voltage [kv] Induction Base area s Lightning attachment point Height Corner Side Center 2 m x 2 m Corner m Center wire m x 2 m Corner m Center wire m x 2 m Corner m Center wire m x 2 m Corner m Center wire m x 6 m Corner m Center wire Table 6: Separation distance for LPS type a (k m = 1) Structure Separation distance [cm] Induction Base area Loop Lightning attachment point Height Corner Side Center 2 m x 2 m Corner 29 9,6 7,3 1 m Center wire 6,1 8, m x 2 m Corner m Center wire m x 2 m Corner m Center wire m x 2 m Corner m Center wire m x 6 m Corner 28 2,1 3,2 1 m Center wire 2,5 3,

10 In the following, the CONCEPT calculation results are compared to the calculation results according to IEC , clause 6.3 and annex C (Eq. (1,3) in section 1). Fig. 13 illustrates the separation distances for the cases of corner strike and center strike. For the corner strike, the calculations with CONCEPT reveal separation distances being about 15 % to 3 % higher compared to IEC The deviations are due to the fact that in IEC the k i - values were reduced by 2 % compared to the original calculation results [3-5]. s [cm] Center strike Concept VDE 185 CONCEPT IEC m x 6m 1m 2m 4m 6m 1m s [cm] Corner strike Concept VDE 185 CONCEPT IEC m x 6m 1m 2m 4m 6m 1m Fig. 13 Comparison of the separation distances resulting from the CONCEPT computer code and from IEC (eq. (3)) for the cases of corner strike and center strike to LPS type a For the center strike, the deviations are much higher between the CONCEPT computation and IEC : The values determined according to the formula of IEC are higher by a factor of about 1,5 2,5. These high separation distances are due to the modified calculation method of IEC Whereas originally [3,4] only the height between the equipotential plane bonding point and the location of the proximity is considered, according to IEC now the total length of the path along the air termination and the down s is to consider for the length l in Eq. (1). 7.2 LPS type b with flat metal roof Table 7 summarizes the separation distances for the LPS type b using flat metal roofs (k m = 1). For the structure with 2 m x 2 m of base area, the separation distances are fairly independent on the location of the striking points and of the induction. On contrast, the structure with the large base area of 6 m x 6 m has a somewhat different trend. Anyhow, the highest value of the separation distance (6,1 cm) is very low and 3 % less compared to the 2 m x 2 m structure of the same height of 1 m. Table 7: Separation distance for LPS type b (k m = 1) Structure Separation distance [cm] Induction Base area Lightning attachment point Height Corner Side Center 2 m x 2 m Corner 8,4 8,1 7,8 1 m Center wire 7,6 7,8 7,8 2 m x 2 m Corner m Center wire m x 2 m Corner m Center wire m x 2 m Corner m Center wire m x 6 m Corner 6,1 2,8 2,2 1 m Center wire 2,4 2,6 2,6 1

11 Compared to LPS type a, the use of a metal roof reduces the separation distances significantly, especially for low structures of 1 m or 2 m of height. For these low structures the reduction factors vary from about 2 to 4. For higher structures the reduction is less pronounced. Fig. 14 shows the separation distances for the structures with 2 m x 2 m base area as function of the structure height. The following linear relation is found for the separation distance s and the structure height h (for a class II LPS): s = k h, 83 h (12) An approach for structures with a metal roof and classical down s with rounded up figures, also allowing for some safety margin, could be: h s = k (13) k m The constants k could be,12 for a class I LPS,,9 for a class II LPS and,6 for a class III/IV LPS. The coefficient k m denotes the material factor as in Eq. (1). s [cm] h [m] Fig. 14 Separation distance s for the 2 m x 2 m base area structures of LPS type b (metal roof) as function of the structure height h. 7.3 LPS type c with metal walls The LPS type c uses metal walls as down system and meshed metal wires for the air termination system. The calculations revealed induced voltages typically strongly oscillating. Because the constant-area-criterion given by Eq. (4-6) applies only for unipolar impulse voltages, the separation distance cannot be specified in detail. Therefore, only the peak values of the induced voltages are summarized in Table 8. For the induced voltages the following two cases are found distinguishing between the locations of the lightning attachment point: 1. In case of the corner and side strike, the attachment point is directly at the top of the metal walls (see Fig. 8). In these cases the induced voltages are always less than 5 kv, irrespective of the structure height. Due to these low voltage level, a separation distance of s 15 cm seems to be adequate concerning the class II lightning protection system according to IEC In the case of center strike, the peak values of the induced voltages (in the center wire) are close to the values found for LPS type a, seen in Table 5. Obviously, in case of the center strike use of metal walls does not reduce the separation distances significantly. The values given in Table 8 are based on ideal metal walls directly connected to the equipotential plane. In reality, however, short metal wires are used to connect the metal facades to the earth termination system. The influence of 1 m long connecting wires is examined for the structure with the base area of 2 m x 2 m and the height of 1 m. The interspacing between the connecting wires is taken into account with 5 m and 1 m, respectively. Table 9 summarizes the results in comparison to the ideal case of the walls directly connected to the equipotential plane. Only the values of the worst-case combinations corner strike/corner and center strike/center wire are given. The results reveal that the use of such connecting wires increases the induced voltages only marginally by less than 1 %. 11

12 Structure Table 8: Induced voltage for LPS type c (k m = 1) Peak voltage [kv] Base area Induction Lightning attachment point Height Corner Side Center 2 m x 2 m Corner m Center wire m x 2 m Corner m Center wire m x 6 m Corner m Center wire Table 9: Influence of the wires connecting the metal walls to the equipotential plane on the induced voltages for LPS type c (k m = 1). The connecting wires are 1 m long and the 1 m high structure has the base area of 2 m x 2 m. Interspacing between the connecting wires Induction Peak voltage [kv] Lightning attachment point Corner Center Walls directly connected to Corner ground plane Center wire m - Interspacing 1 m - Interspacing Corner Center wire - 17 Corner Center wire LPS type d with circumferential metal attic at the roof The influence of the circumferential metal attic (see Fig. 9) is examined for the structure with the dimensions of 2 m x 2 m x 2 m and for two flat attic sheets having a width of,5 m and 1 m. Table 1 summarizes the resulting separation distances in comparison to the LPS type a configuration without attic. For the cases of side strike and center strike no significant reduction of the separation distance is found, irrespective of the sheet width. Only for the worst-case combination of corner strike/corner the separation distance is reduced by about 3 % for the sheets width of,5 m and by about 4 % for the sheets width of 1 m. Table 1: Separation distance for LPS type d (k m = 1) with the base area of 2 m x 2 m and the height of 2 m circumferential metal attic at the roof Without attic,5 m 1, m Separation distance [cm] Induction Lightning attachment point Corner Side Center Corner Center wire Corner Center wire Corner Center wire

13 8 CONCLUSION Extensive sheet metal plates used as natural components of lightning protection systems may reduce the separation distances considerably. In the present paper the influence of metal roofs, of metal facades and of metal circumferential attics is analyzed. The calculations are based on the CONCEPT II computer code which solves the Maxwell s Equations with the Method of Moments in the frequency domain. The use of metal roofs can reduce the separation distances significantly by the factor of about Here, the separation distance is proportional to the height of the proximity over the equipotential plane. For metal walls two different cases are found depending on the location of the point of strike: If the point strike is at the top of the metal wall as is the case of the corner strike and the side strike, the separation distances are relatively small. For instance, about 15 cm are sufficient to keep the required separation distances for class II lightning protection system according to IEC In case of center strike, however, the use of a metal facade gives only marginal reduction of the separation distances. In this case the induction resulting from the air termination wires on the roof dominate. The use of a circumferential metal attic is of minor influence, whereat the separation distance is reduced by some tens of percents, at best. 9 REFERENCES [1] IEC :26-1, Protection against lightning - Part 1: General principles, Jan. 26. [2] IEC :26-1, Protection against lightning-part 3: Physical damage to structures and life hazard, Jan. 26. [3] O. Beierl, H. Steinbigler, "Induced over-voltages at lightning protection systems with meshed air termination s, Proc. of the 18 th International Conference on Lightning Protection ICLP, Munich, paper 4.1, Sep (in German). [4] W. Zischank, Isolated lightning protection systems for buildings with flammable content, Proc. of the 19 th International Conference on Lightning Protection ICLP, paper 6.8, Graz, April 1988 (in German). [5] IEC , Protection of structures against lightning, Ed. 2., [6] D. Kind, The constant-area-criterion for impuls voltages at electrodes in air, Ph. D. Thesis, Technical University Munich, 1957 (in German) [7] L. Thione, The Dielectric Strength of Large Air Insulation in K. Ragaller: Surges in High-Voltage Networks, Plenum Press, New York, 198. [8] H. Bruens, Pulse generated electromagnetic response in three-dimensional wire structures, Ph. D. Thesis, University of the Federal Armed Forces Hamburg, Germany, 1985 (in German). [9] R.F. Harrington, Field Calculations by Moment Methods, New York, The MacMillan Company, [1]H. Bruens, D. Koenigstein, Calculation and measurements of transient electromagnetic fields in EMP simulators, Proc. of the 6th Symposium on Electromagnetic Compati-bility, Zurich, paper 66L2, pp , March [11]H. Singer, H. Brüns, T. Mader, A. Freiberg, CONCEPT II Manual of the program system, University Hamburg-Harburg, Germany, 23. [12]M.A. Uman, R.D. Brantley, Y.T. Lin, J.A. Tiller, E.P. Krider, D.K. McLain, Correlated electric and magnetic fields from lightning return strokes, J. Geophysical. Res., vol. 8, pp , Jan [13]H. Bruens, H. Singer, F. Demmel, Calculation of transient processes at direct lightning stroke into thin wire structures, Proc. of the 7th Symposium on Electromagnetic Compatibility, Zurich, paper 17D5, pp. 85-9, March [14]W. Zischank, F. Heidler, Reduction of separation distances by using extensive metal parts as natural components of the external lightning protection system, Proc. of the 29 th International Conference on Lightning Protection ICLP, Uppsala, Sweden, paper 1-1, June 28. [15]F. Heidler, W. Zischank, A. Kern, Analysis of necessary separation distances for lightning protection systems including natural components, Proc. of the 28th Intern. Conf. on Lightning Protection ICLP, Kanazawa, Japan, vol. II, report X-1, pp , Sep

DETERMINATION OF THE DIELECTRIC STRENGTH OF LPS COMPONENTS BY APPLICATION OF THE CONSTANT-AREA-CRITERION

DETERMINATION OF THE DIELECTRIC STRENGTH OF LPS COMPONENTS BY APPLICATION OF THE CONSTANT-AREA-CRITERION X International Symposium on Lightning Protection 9 th -13 th November, 29 Curitiba, Brazil DETERMINATION OF THE DIELECTRIC STRENGTH OF LPS COMPONENTS BY APPLICATION OF THE CONSTANT-AREA-CRITERION Ottmar

More information

Application of Lightning Location System Data for Designing the External Lightning Protection System

Application of Lightning Location System Data for Designing the External Lightning Protection System 21, rue d Artois, F-758 PARIS International Colloquium INSA LYON http : //www.cigre.org on Lightning and Power systems France Application of Lightning Location System Data for Designing the External Lightning

More information

Experimental and Analytical Studies on Lightning Surge Response of 500kV Transmission Tower

Experimental and Analytical Studies on Lightning Surge Response of 500kV Transmission Tower Experimental and Analytical Studies on Lightning Surge Response of 500kV Transmission Tower H. Motoyama, CRIEPI, Japan motoyama@criepi.denken.or.jp Y. Kinoshita, Chube Electric Power Co., Inc., Japan K.

More information

Electrodynamic Forces Affecting Lightning Protection System Components and Structures

Electrodynamic Forces Affecting Lightning Protection System Components and Structures 2014 International Conference on Lightning Protection (ICLP), Shanghai, China Electrodynamic Forces Affecting Lightning Protection System Components and Structures Volodymyr Shostak, Mikhailo Sypchenko

More information

THE EARLY STREAMER EMISSION PRINCIPLE DOES NOT WORK UNDER NATURAL LIGHTNING!!

THE EARLY STREAMER EMISSION PRINCIPLE DOES NOT WORK UNDER NATURAL LIGHTNING!! IX International Symposium on Lightning Protection 26 th -30 th November 2007 Foz do Iguaçu, Brazil THE EARLY STREAMER EMISSION PRINCIPLE DOES NOT WORK UNDER NATURAL LIGHTNING!! Marley Becerra Vernon Cooray

More information

Lightning Phenomenology Notes Note 23 8 Jan Lightning Responses on a Finite Cylindrical Enclosure

Lightning Phenomenology Notes Note 23 8 Jan Lightning Responses on a Finite Cylindrical Enclosure Lightning Phenomenology Notes Note 23 8 Jan 2014 Lightning Responses on a Finite Cylindrical Enclosure Kenneth C. Chen and Larry K. Warne Sandia National Laboratories, P. O. Box 5800, Albuquerque, NM 87185,

More information

An Optimised High Current Impulse Source

An Optimised High Current Impulse Source An Optimised High Current Impulse Source S. Kempen, D. Peier Institute of High Voltage Engineering, University of Dortmund, Germany Abstract Starting from a predefined 8/0 µs impulse current, the design

More information

Modeling of Transmission Line and Substation for Insulation Coordination Studies

Modeling of Transmission Line and Substation for Insulation Coordination Studies TRAINING DUBROVNIK, CROATIA - APRIL, 27-29 2009 SIMULATION & ANALYSIS OF POWER SYSTEM TRANSIENTS WITH EMTP-RV Modeling of Transmission Line and Substation for Insulation Coordination Studies Prof. Ivo

More information

Implementation of a Transmission Line Model with the PEEC Method for Lightning Surge Analysis

Implementation of a Transmission Line Model with the PEEC Method for Lightning Surge Analysis Implementation of a Transmission Line Model with the PEEC Method for Lightning Surge Analysis PEERAWUT YUTTHAGOWITH Department of Electrical Engineering, Faculty of Engineering King Mongkut s Institute

More information

Influence of Grounding Material s Property on the Impulse Grounding Resistance of Grounding Grids

Influence of Grounding Material s Property on the Impulse Grounding Resistance of Grounding Grids International Conference on Electrical, Electronics and Mechatronics (ICEEM 2015) Influence of Grounding Material s Property on the Impulse Grounding Resistance of Grounding Grids Leishi Xiao1, Qian Li1

More information

Analyses of characteristics of spatial lightning electromagnetic field at different horizontal distances and observation point heights

Analyses of characteristics of spatial lightning electromagnetic field at different horizontal distances and observation point heights Journal of Physics: Conference Series Analyses of characteristics of spatial lightning electromagnetic field at different horizontal distances and observation point heights To cite this article: Xiaojia

More information

Copyright 2014 IEEE. Paper presented at 2014 IEEE conference on electrical insulation and dielectric phenomena, Des Moines, USA, October, 2014.

Copyright 2014 IEEE. Paper presented at 2014 IEEE conference on electrical insulation and dielectric phenomena, Des Moines, USA, October, 2014. Copyright 2014 IEEE Paper presented at 2014 IEEE conference on electrical insulation and dielectric phenomena, Des Moines, USA, 19-22 October, 2014. This material is posted here with the permission of

More information

The leader propagation velocity in long air gaps

The leader propagation velocity in long air gaps The leader propagation velocity in long air gaps Liliana Arevalo, Dong Wu Research and development ABB Power Grids, HVDC Ludvika, Sweden Liliana.Arevalo@se.abb.com Pasan Hettiarachchi, Vernon Cooray, André

More information

Correlated time derivatives of current, electric field intensity, and magnetic flux density for triggered lightning at 15 m

Correlated time derivatives of current, electric field intensity, and magnetic flux density for triggered lightning at 15 m JOURNAL OF GEOPHYSICAL RESEARCH, VOL. 107, NO. D13, 4160, 10.1029/2000JD000249, 2002 Correlated time derivatives of current, electric field intensity, and magnetic flux density for triggered lightning

More information

xˆ z ˆ. A second vector is given by B 2xˆ yˆ 2z ˆ.

xˆ z ˆ. A second vector is given by B 2xˆ yˆ 2z ˆ. Directions for all homework submissions Submit your work on plain-white or engineering paper (not lined notebook paper). Write each problem statement above each solution. Report answers using decimals

More information

Transient analysis of the behaviour of grounding systems consisted by driven rods

Transient analysis of the behaviour of grounding systems consisted by driven rods Transient analysis of the behaviour of grounding systems consisted by driven rods I.F. GONOS M.K. ANTONIOU I.A. STATHOPULOS F.V. TOPALIS Department of Electrical and Computer Engineering, High Voltage

More information

FREQUENCY DEPENDENT CHARACTERISTICS OF GROUNDING SYSTEM BURIED IN MULTILAYERED EARTH MODEL BASED ON QUASI-STATIC ELECTRO- MAGNETIC FIELD THEORY

FREQUENCY DEPENDENT CHARACTERISTICS OF GROUNDING SYSTEM BURIED IN MULTILAYERED EARTH MODEL BASED ON QUASI-STATIC ELECTRO- MAGNETIC FIELD THEORY Progress In Electromagnetics Research M, Vol. 33, 169 183, 2013 FREQUENCY DEPENDENT CHARACTERISTICS OF GROUNDING SYSTEM BURIED IN MULTILAYERED EARTH MODEL BASED ON QUASI-STATIC ELECTRO- MAGNETIC FIELD

More information

DIRECT STROKE LIGHTNING PROTECTION DESIGN

DIRECT STROKE LIGHTNING PROTECTION DESIGN International Journal of Research in Engineering and Applied Sciences(IJREAS) Available online at http://euroasiapub.org/journals.php Vol. 7 Issue 1,January7, pp. 1~12cv ISSN (O): 2249-3905, ISSN(P) :

More information

Boundary element modelling of the metalic post protection zone

Boundary element modelling of the metalic post protection zone Boundary element modelling of the metalic post protection zone B. 3ajac1, D. poljak2 &N. ~0vai5' I Department of Electrical Engineering, University of Split, Croatia 2 Department of Electronics, University

More information

DC/DC regulator Input V Output up to 16 A

DC/DC regulator Input V Output up to 16 A PMC 4000 series Contents Product Program...................... 2 Mechanical Data...................... 3 Connections......................... 3 Absolute Maximum Ratings............. 4 Input...............................

More information

Recent Improvements in K-Factor Models

Recent Improvements in K-Factor Models 1 Recent Improvements in K-Factor Models Yixin Zhang NEETRAC, Georgia Institute of Technology 2014 IEEE PES Panel Session Discussions on IEEE Std.4-2013: High-Voltage Testing Techniques 2 Related Standards

More information

Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2

Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2 Electrical, Electronic and Computer Engineering ENEL4HB - High oltage 2 Main Examination October 2016 Instructions Answer all questions, show all working and include all necessary comments (it is your

More information

An Empirical Formula for the Surge Impedance of a Grounding Conductor along a Reinforced Concrete Pole in a Distribution Line

An Empirical Formula for the Surge Impedance of a Grounding Conductor along a Reinforced Concrete Pole in a Distribution Line An Empirical Formula for the Surge Impedance of a Grounding Conductor along a Reinforced Concrete Pole in a istribution Line T. Mozumi N. Nagaoka A. Ametani S. Sekioka oshisha University Kyo-tanabe, 61-321,

More information

Lightning Protection Of Wind Turbines

Lightning Protection Of Wind Turbines Lightning Protection Of Wind Turbines By Vidyadhar Peesapati Electrical Energy and Power Systems Group University Of Manchester 1.1 LIGHTNING PROTECTION OF WIND TURBINES What is lightning? Lightning is

More information

Outline of College Physics OpenStax Book

Outline of College Physics OpenStax Book Outline of College Physics OpenStax Book Taken from the online version of the book Dec. 27, 2017 18. Electric Charge and Electric Field 18.1. Static Electricity and Charge: Conservation of Charge Define

More information

A Roadmap for Evaluation of Lightning Elimination Technologies

A Roadmap for Evaluation of Lightning Elimination Technologies Non-Conventional Lightning Mitigation: Fact or Fiction? A Roadmap for Evaluation of Lightning Elimination Technologies IEEE PES 2003 General Meeting July 16, 2003 Purpose of Talk Review methods that have

More information

Effective Design of Large Grounding Systems

Effective Design of Large Grounding Systems Effective Design of Large Grounding Systems Lorentzou M.I. Hatziargyriou N.D. National Technical University of Athens Department of Electrical Engineering 9 Heroon Politechniou, Zografou Campus, Athens,

More information

HIGH FREQUENCY CURRENT DISTRIBUTION IN A STRUCTURE WITH APPLICATION TO LIGHTNING PROTECTION SYSTEMS

HIGH FREQUENCY CURRENT DISTRIBUTION IN A STRUCTURE WITH APPLICATION TO LIGHTNING PROTECTION SYSTEMS HIGH FREQUENCY CURRENT DISTRIBUTION IN A STRUCTURE WITH APPLICATION TO LIGHTNING PROTECTION SYSTEMS Andrew Graham Swanson A research report submitted to the faculty of Engineering and the Built Environment,

More information

Comparison of Finite Element Analysis to IEC for Predicting Underground Cable Ampacity

Comparison of Finite Element Analysis to IEC for Predicting Underground Cable Ampacity Comparison of Finite Element Analysis to IEC-60287 for Predicting Underground Cable Ampacity Simon Dubitsky Tor Ltd, St. Petersburg, Russia simon.dubitsky@ieee.org Georgy Greshnyakov Sevkabel Research

More information

Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2

Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2 Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2 Main Examination October 2015 Instructions Answer all questions and show all working. Time allowed = 2 hours Full marks = 100 Question

More information

Film Capacitors. EMI suppression capacitors. Date: June 2018

Film Capacitors. EMI suppression capacitors. Date: June 2018 Film Capacitors EMI suppression capacitors Date: June 2018 EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without

More information

NUMERICAL ANALYSES OF ELECTROMAGNETIC FIELDS IN HIGH VOLTAGE BUSHING AND IN ELECTROMAGNETIC FLOW METER

NUMERICAL ANALYSES OF ELECTROMAGNETIC FIELDS IN HIGH VOLTAGE BUSHING AND IN ELECTROMAGNETIC FLOW METER Intensive Programme Renewable Energy Sources May 2011, Železná Ruda-Špičák, University of West Bohemia, Czech Republic NUMERICAL ANALYSES OF ELECTROMAGNETIC FIELDS IN HIGH VOLTAGE BUSHING AND IN ELECTROMAGNETIC

More information

Measuring Lightning Currents on Wind Turbines

Measuring Lightning Currents on Wind Turbines 4 th International Symposium on Winter Lightning (ISWL2017) Measuring Lightning Currents on Wind Turbines J. Birkl, DEHN+SOEHNE GmbH + Co. KG., Neumarkt, Germany E. Shulzhenko, Group for Lightning and

More information

Evaluation of the risk of failure due to switching overvoltages of a phase to phase insulation

Evaluation of the risk of failure due to switching overvoltages of a phase to phase insulation Evaluation of the risk of failure due to switching overvoltages of a phase to phase insulation A. Xemard, J. Michaud, A. Guerrier, I. Uglesic, G. Levacic, M. Mesic Abstract-- The upgrade of an overhead

More information

Partial discharge (PD) is well established as a diagnostic

Partial discharge (PD) is well established as a diagnostic F E A T U R E A R T I C L E Application of Maxwell Solvers to PD Propagation Part I: Concepts and Codes Key Words: Partial discharge propagation, electromagnetic field analysis, Maxwell solvers, boundary

More information

Sandia National Laboratories, P. O. Box 5800, Albuquerque, NM 87185, USA

Sandia National Laboratories, P. O. Box 5800, Albuquerque, NM 87185, USA Progress In Electromagnetics Research M, Vol. 23, 299 3, 22 LINEAR DIFFUSION INTO A FARADAY CAGE K. C. Chen *, Y. T. Lin, L. K. Warne, and K. O. Merewether Sandia National Laboratories, P. O. Box 58, Albuquerque,

More information

Lightning Effect on Scaled Protected and Un-Protected Building Structures and the Air Terminal Bypasses

Lightning Effect on Scaled Protected and Un-Protected Building Structures and the Air Terminal Bypasses Indonesian Journal of Electrical Engineering and Computer Science Vol.11, No.1, July 2018, pp. 182~186 ISSN: 2502-4752, DOI: 10.11591/ijeecs.v11.i1.pp182-186 182 Lightning Effect on Scaled Protected and

More information

COPPER FOR BUSBARS CHAPTER 4: SHORT-CIRCUIT EFFECTS

COPPER FOR BUSBARS CHAPTER 4: SHORT-CIRCUIT EFFECTS European Copper Institute COPPER FOR BUSBARS CHAPTER 4: SHORT-CIRCUIT EFFECTS David Chapman August 2011 ECI Available from www.leonardo-energy.org Document Issue Control Sheet Document Title: Publication

More information

Parameters of Rocket-Triggered Lightning

Parameters of Rocket-Triggered Lightning 80 International Journal of Plasma Environmental Science & Technology, Vol.4, No.1, MARCH 2010 Parameters of Rocket-Triggered Lightning V. A. Rakov Department of Electrical and Computer Engineering, University

More information

Characteristics and Definitions Used for Film Capacitors

Characteristics and Definitions Used for Film Capacitors Characteristics and Definitions Used for Film Capacitors COMMON FILM DIELECTRICS USED IN FILM CAPACITORS PRODUCTS PARAMETER DIELECTRIC (1) UNIT Dielectric constant 1 khz 3.3 3 3. - Dissipation factor 1

More information

Two point charges, A and B, lie along a line separated by a distance L. The point x is the midpoint of their separation.

Two point charges, A and B, lie along a line separated by a distance L. The point x is the midpoint of their separation. Use the following to answer question 1. Two point charges, A and B, lie along a line separated by a distance L. The point x is the midpoint of their separation. 1. Which combination of charges would yield

More information

Lightning Protection Of Wind Turbines. EWEC 2010 Warsaw Poland By Vidyadhar Peesapati

Lightning Protection Of Wind Turbines. EWEC 2010 Warsaw Poland By Vidyadhar Peesapati Lightning Protection Of Wind Turbines EWEC 2010 Warsaw Poland By Vidyadhar Peesapati LIGHTNING What is lightning? Lightning is an electrical discharge in the atmosphere, very similar to a spark. It is

More information

Physics 240 Fall 2003: Final Exam. Please print your name: Please list your discussion section number: Please list your discussion instructor:

Physics 240 Fall 2003: Final Exam. Please print your name: Please list your discussion section number: Please list your discussion instructor: Physics 40 Fall 003: Final Exam Please print your name: Please list your discussion section number: Please list your discussion instructor: Form #1 Instructions 1. Fill in your name above. This will be

More information

, times the dielectric constant of the material, k d. . With these definitions, Eq. 1 can be written as:

, times the dielectric constant of the material, k d. . With these definitions, Eq. 1 can be written as: Introduction An Examination of Lightning-Strike-Grounding Physics by C. B. Moore, G. D. Aulich and William Rison Langmuir Laboratory for Atmospheric Research, New Mexico Tech, Socorro, NM 87801 Observations

More information

STUDIES ON LIGHTNING CHARACTERISTICS

STUDIES ON LIGHTNING CHARACTERISTICS STUDIES ON LIGHTNING CHARACTERISTICS Lohit Singh.G 1, Piyush Kankariya 1, Rakesh Kumar 1, Varun.P 1, Shreyas 1, Madhu Palati 2 1 UG Student, 2 Assistant Professor, 1, 2 Department of Electrical & Electronics

More information

TYPE. max. working voltage 250 V 350 V 500 V 750 V. max. overload voltage 500 V 700 V 1000 V 1500 V. basic specifications IEC B

TYPE. max. working voltage 250 V 350 V 500 V 750 V. max. overload voltage 500 V 700 V 1000 V 1500 V. basic specifications IEC B FEATURES Non inductive High pulse loading capability. APPLICATIONS Application for overload and high voltage surge hazard circuits. DESCRIPTION A carbon film is deposited on a high grade ceramic body.

More information

Microwave Phase Shift Using Ferrite Filled Waveguide Below Cutoff

Microwave Phase Shift Using Ferrite Filled Waveguide Below Cutoff Microwave Phase Shift Using Ferrite Filled Waveguide Below Cutoff CHARLES R. BOYD, JR. Microwave Applications Group, Santa Maria, California, U. S. A. ABSTRACT Unlike conventional waveguides, lossless

More information

Physics 2220 Fall 2010 George Williams THIRD MIDTERM - REVIEW PROBLEMS

Physics 2220 Fall 2010 George Williams THIRD MIDTERM - REVIEW PROBLEMS Physics 2220 Fall 2010 George Williams THIRD MIDTERM - REVIEW PROBLEMS Solution sets are available on the course web site. A data sheet is provided. Problems marked by "*" do not have solutions. 1. An

More information

Physics 42 Exam 3 Spring 2016 Name: M T W

Physics 42 Exam 3 Spring 2016 Name: M T W Physics 42 Exam 3 Spring 2016 Name: M T W Conceptual Questions & Shorty (2 points each) 1. Which magnetic field causes the observed force? 2. If released from rest, the current loop will move a. upward

More information

AC Circuits. The Capacitor

AC Circuits. The Capacitor The Capacitor Two conductors in close proximity (and electrically isolated from one another) form a capacitor. An electric field is produced by charge differences between the conductors. The capacitance

More information

Conventional Paper-I-2011 PART-A

Conventional Paper-I-2011 PART-A Conventional Paper-I-0 PART-A.a Give five properties of static magnetic field intensity. What are the different methods by which it can be calculated? Write a Maxwell s equation relating this in integral

More information

EPRI Lightning Protection Design Workstation

EPRI Lightning Protection Design Workstation EPRI Lightning Protection Design Workstation Tom McDermott Electrotek Concepts, Inc. 2000 Winter Power Meeting LPDW v5 Components Includes 1988-97 flash data from the National Lightning Detection Network

More information

EXPERIMENTAL DEVELOPMENTS ON SOIL IONIZATION: NEW FINDINGS

EXPERIMENTAL DEVELOPMENTS ON SOIL IONIZATION: NEW FINDINGS GROUND 2008 & 3 rd LPE International Conference on Grounding and Earthing & 3 rd International Conference on Lightning Physics and Effects Florianopolis - Brazil November, 2008 EXPERIMENTAL DEVELOPMENTS

More information

MAGNETIC NOZZLE PLASMA EXHAUST SIMULATION FOR THE VASIMR ADVANCED PROPULSION CONCEPT

MAGNETIC NOZZLE PLASMA EXHAUST SIMULATION FOR THE VASIMR ADVANCED PROPULSION CONCEPT MAGNETIC NOZZLE PLASMA EXHAUST SIMULATION FOR THE VASIMR ADVANCED PROPULSION CONCEPT ABSTRACT A. G. Tarditi and J. V. Shebalin Advanced Space Propulsion Laboratory NASA Johnson Space Center Houston, TX

More information

Measurement of the electric field at the near field radiating by electrostatic discharges

Measurement of the electric field at the near field radiating by electrostatic discharges Proceedings of the 6th WSEAS International Conference on Instrumentation, Measurement, Circuits & Systems, Hangzhou, China, April 15-17, 2007 43 Measurement of the electric field at the near field radiating

More information

Overhead lines. 110 kv wood tower with guy wires

Overhead lines. 110 kv wood tower with guy wires Overhead lines a) ja b) 0 kv wood poles c) free standing 0 kv metal tower with I-strings d) free standing 440 kv metal tower with V-strings e) 400 kv metal tower with guy wires 0 kv wood tower with guy

More information

66kV & 220kV Substation Protection From Lightning by Fixed Angle, Rolling Sphere and Early Streamer Method

66kV & 220kV Substation Protection From Lightning by Fixed Angle, Rolling Sphere and Early Streamer Method RESEARCH ARTICLE OPEN ACCESS 66kV & 220kV Substation Protection From Lightning by Fixed Angle, Rolling Sphere and Early Streamer Method Pruthak C. Chauhan. 1, Rinkesh S. Kansara 2, Mukesh P. Patel 3, Anil

More information

HAL501...HAL506, HAL508 Hall Effect Sensor ICs MICRONAS INTERMETALL MICRONAS. Edition May 5, DS

HAL501...HAL506, HAL508 Hall Effect Sensor ICs MICRONAS INTERMETALL MICRONAS. Edition May 5, DS MICRONAS INTERMETALL HAL1...HAL, HAL Hall Effect Sensor ICs Edition May, 1997 1--1DS MICRONAS HAL1...HAL HAL Hall Effect Sensor IC in CMOS technology Common Features: switching offset compensation at khz

More information

188 Equating the moments of above two forces about point O, we get, T y = w x x or y = w x T The maximum dip (sag) is represented by the value of y at

188 Equating the moments of above two forces about point O, we get, T y = w x x or y = w x T The maximum dip (sag) is represented by the value of y at 187 Fig. 8.3. (i) shows a conductor suspended between two equilevel supports A and B. The conductor is not fully stretched but is allowed to have a dip. The lowest point on the conductor is O and the sag

More information

OR Explain thermal breakdown in solid dielectrics. How this mechanism is

OR Explain thermal breakdown in solid dielectrics. How this mechanism is Subject : High Voltage Engineering (2090) ITM Universe, Vadodara Electrical Engineering Department Class : Electrical Sem : th Long Questions Sr. No Question Unit No : 0 Explain Charge Simulation method

More information

Final Exam Physics 7b Section 2 Fall 2004 R Packard. Section Number:

Final Exam Physics 7b Section 2 Fall 2004 R Packard. Section Number: Final Exam Physics 7b Section 2 Fall 2004 R Packard Name: SID: Section Number: The relative weight of each problem is stated next to the problem. Work the easier ones first. Define physical quantities

More information

Test method to assess the suitability of materials and surfaces to avoid problems from static electricity by measurement of capacitance loading

Test method to assess the suitability of materials and surfaces to avoid problems from static electricity by measurement of capacitance loading 1 of 15 JCI 12 October 2001 Test method to assess the suitability of materials and surfaces to avoid problems from static electricity by measurement of capacitance loading 1 Introduction This document

More information

Phys 132: Supplementary Exercises

Phys 132: Supplementary Exercises Phys 132 Fall 2017 Phys 132: Supplementary Exercises 1 Charged spheres Various identical metal spheres are separated and charged. The excess charges on each sphere, whose charges have the same magnitude,

More information

A SIMPLIFIED RELATIONSHIP BETWEEN SURFACE TRANSFER IMPEDANCE AND MODE STIRRED CHAMBER SHIELDING EFFECTIVENESS OF CABLES AND CONNECTORS

A SIMPLIFIED RELATIONSHIP BETWEEN SURFACE TRANSFER IMPEDANCE AND MODE STIRRED CHAMBER SHIELDING EFFECTIVENESS OF CABLES AND CONNECTORS Record of the EMC Europe 22 International Symposium on Electromagnetic Compatibility, Sorrento, Italy, September 22, pp 441-4461 A SIMPLIFIED RELATIONSHIP BETWEEN SURFACE TRANSFER IMPEDANCE AND MODE STIRRED

More information

Study of Time Correlation Between Lightning Data Recorded by LLS and Relay Protection

Study of Time Correlation Between Lightning Data Recorded by LLS and Relay Protection 2012 International Conference on Lightning Protection (ICLP), Vienna, Austria Study of Time Correlation Between Lightning Data Recorded by LLS and Relay Protection Ivo Uglešić, Viktor Milardić, Bojan Franc

More information

The Booster has three magnet systems for extraction: Kicker Ke, comprising two identical magnets and power supplies Septum Se

The Booster has three magnet systems for extraction: Kicker Ke, comprising two identical magnets and power supplies Septum Se 3.2.7 Booster Injection and Extraction 3.2.7.1 Overview The Booster has two magnet systems for injection: Septum Si Kicker Ki The Booster has three magnet systems for extraction: Kicker Ke, comprising

More information

An ion follows a circular path in a uniform magnetic field. Which single change decreases the radius of the path?

An ion follows a circular path in a uniform magnetic field. Which single change decreases the radius of the path? T5-1 [237 marks] 1. A circuit is formed by connecting a resistor between the terminals of a battery of electromotive force (emf) 6 V. The battery has internal resistance. Which statement is correct when

More information

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing

More information

AP Physics C. Magnetism - Term 4

AP Physics C. Magnetism - Term 4 AP Physics C Magnetism - Term 4 Interest Packet Term Introduction: AP Physics has been specifically designed to build on physics knowledge previously acquired for a more in depth understanding of the world

More information

Electromagnetic Waves

Electromagnetic Waves Electromagnetic Waves Our discussion on dynamic electromagnetic field is incomplete. I H E An AC current induces a magnetic field, which is also AC and thus induces an AC electric field. H dl Edl J ds

More information

The objective of a grounding system are: 1. To provide safety to personnel during normal and fault conditions by limiting step and touch potential.

The objective of a grounding system are: 1. To provide safety to personnel during normal and fault conditions by limiting step and touch potential. GROUNDING SYSTEMS Part 1 Professor Ahdab Elmorshedy 1 Reference: High Voltage Engineering Theory and Practice, Text Book, Marcel Dekker Inc. NY, USA, 2000. Mazen Abdel-Salam, Hussein Anis, Ahdab Elmorshedy,

More information

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1 AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1 Picture of product with pencil Introduction The HC6H family is for the electronic measurement of DC, AC or pulsed currents in high power

More information

Electric Fields and Potentials

Electric Fields and Potentials Electric Fields and Potentials INTRODUCTION This experiment is intended to illustrate the concepts of electric fields and electric potentials and how they are related to the charge distribution that produces

More information

Anna University B.E/B.Tech Degree Examination November/December 2010, Seventh Semester, Electrical and Electronics Engineering, EE1402-HIGH VOLTAGE ENGINEERING Answer all the questions. Part-A (10*2=20)

More information

Mansfield Independent School District AP Physics C: Electricity and Magnetism Year at a Glance

Mansfield Independent School District AP Physics C: Electricity and Magnetism Year at a Glance Mansfield Independent School District AP Physics C: Electricity and Magnetism Year at a Glance First Six-Weeks Second Six-Weeks Third Six-Weeks Lab safety Lab practices and ethical practices Math and Calculus

More information

LIGHTNING PHYSICS AND LIGHTNING PROTECTION: STATE OF ART 2013 Prof. Carlo Mazzetti di Pietralata

LIGHTNING PHYSICS AND LIGHTNING PROTECTION: STATE OF ART 2013 Prof. Carlo Mazzetti di Pietralata LIGHTNING PHYSICS AND LIGHTNING PROTECTION: STATE OF ART 2013 Prof. Carlo Mazzetti di Pietralata 1st October 2013, Warsaw WARSAW UNIVERSITY OF TECHNOLOGY TOPICS 1. Physics 2. Modern research method 3.

More information

EFFECTIVENESS OF WORLDWIDE EXISTING ESE LIGHTNING PROTECTION SYSTEMS MANUFACTURED IN EUROPE

EFFECTIVENESS OF WORLDWIDE EXISTING ESE LIGHTNING PROTECTION SYSTEMS MANUFACTURED IN EUROPE EFFECTIVENESS OF WORLDWIDE EXISTING ESE LIGHTNING PROTECTION SYSTEMS MANUFACTURED IN EUROPE V.Pomar, S.Polo (Aplicaciones Tecnológicas, S.A.) S. Fauveaux (Indelec) Abstract Scientific basis of any kind

More information

Fault Calculation Methods

Fault Calculation Methods ELEC9713 Industrial and Commercial Power Systems Fault Calculation Methods There are two major problems that can occur in electrical systems: these are open circuits and short circuits. Of the two, the

More information

1. Explain the various methods of methods of grounding. In power system, grounding or earthing means connecting frame of electrical equipment (non-cur

1. Explain the various methods of methods of grounding. In power system, grounding or earthing means connecting frame of electrical equipment (non-cur 1. Explain the various methods of methods of grounding. In power system, grounding or earthing means connecting frame of electrical equipment (non-current carrying part) or some electrical part of the

More information

Phys102 Final-163 Zero Version Coordinator: Saleem Rao Tuesday, August 22, 2017 Page: 1. = m/s

Phys102 Final-163 Zero Version Coordinator: Saleem Rao Tuesday, August 22, 2017 Page: 1. = m/s Coordinator: Saleem Rao Tuesday, August 22, 2017 Page: 1 Q1. A 125 cm long string has a mass of 2.00 g and a tension of 7.00 N. Find the lowest resonant frequency of the string. A) 2.5 Hz B) 53.0 Hz C)

More information

High-current Modulator with Nonlinear Coupled Tank Circuits

High-current Modulator with Nonlinear Coupled Tank Circuits PACS : 84.30.Jc;84.70.+p Institute for Electromagnetic Research, Kharkov, Ukraine E-mail:iemr@online.kharkiv.com High-current Modulator with Nonlinear Coupled Tank Circuits Contents 1. Introduction 266

More information

Comparison of Transient Simulations on Overhead Cables by EMTP and FDTD

Comparison of Transient Simulations on Overhead Cables by EMTP and FDTD Comparison of Transient Simulations on Overhead Cables by EMTP and FDTD H. Xue, M. Natsui, A. Ametani, J. Mahseredjian, H. Tanaka, Y. Baba 1 Abstract--Transient simulations on an overhead cable are performed

More information

Physics 1308 Exam 2 Summer 2015

Physics 1308 Exam 2 Summer 2015 Physics 1308 Exam 2 Summer 2015 E2-01 2. The direction of the magnetic field in a certain region of space is determined by firing a test charge into the region with its velocity in various directions in

More information

A Long Term Study on the Performance of Early Streamer Emission Air Terminals in a High Keraunic Region

A Long Term Study on the Performance of Early Streamer Emission Air Terminals in a High Keraunic Region A Long Term Study on the Performance of Early Streamer Emission Air Terminals in a High Keraunic Region Z. A. Hartono and I. Robiah Lightning Research Pte. Ltd. Mail: 457 Jalan B11, Taman Melawati 53100

More information

SP3022 Series 0.35pF 20kV Bidirectional Discrete TVS

SP3022 Series 0.35pF 20kV Bidirectional Discrete TVS 0.35pF 20kV Bidirectional iscrete TVS RoHS Pb GREEN escription The SP3022 includes back-to-back TVS diodes fabricated in a proprietary silicon avalanche technology to provide protection for electronic

More information

Do not fill out the information below until instructed to do so! Name: Signature: Section Number:

Do not fill out the information below until instructed to do so! Name: Signature:   Section Number: Do not fill out the information below until instructed to do so! Name: Signature: E-mail: Section Number: No calculators are allowed in the test. Be sure to put a box around your final answers and clearly

More information

FDTD Calculation of Transient Electromagnetic Fields in the Grounding System of Wind Towers Due to Direct Lightning Strikes

FDTD Calculation of Transient Electromagnetic Fields in the Grounding System of Wind Towers Due to Direct Lightning Strikes Send Orders for Reprints to reprints@benthamscience.net Journal of Lightning Research, 2014, 6, 1-13 1 Open Access FDTD Calculation of Transient Electromagnetic Fields in the Grounding System of Wind Towers

More information

Arrangement of conductors in 220 kv double circuit line to reduce E-fields in view of public exposure

Arrangement of conductors in 220 kv double circuit line to reduce E-fields in view of public exposure Proc. 2018 Electrostatics Joint Conference 1 Arrangement of conductors in 220 kv double circuit line to reduce E-fields in view of public exposure N K Kishore, IIT Kharagpur, INDIA-721032 kishor@ee.iitkgp.ernet.in

More information

Power Engineering II. Power System Transients

Power Engineering II. Power System Transients Power System Transients Oeroltage Maximum supply oltage U m the maximum effectie alue of line oltage that can occur at any time or place under normal operating conditions Rated oltage (k) 6 10 22 35 110

More information

General Physics (PHYC 252) Exam 4

General Physics (PHYC 252) Exam 4 General Physics (PHYC 5) Exam 4 Multiple Choice (6 points). Circle the one best answer for each question. For Questions 1-3, consider a car battery with 1. V emf and internal resistance r of. Ω that is

More information

PROPERTY STUDY ON EMATS WITH VISUALIZATION OF ULTRASONIC PROPAGATION

PROPERTY STUDY ON EMATS WITH VISUALIZATION OF ULTRASONIC PROPAGATION More Info at Open Access Database www.ndt.net/?id=18576 PROPERTY STUDY ON EMATS WITH VISUALIZATION OF ULTRASONIC PROPAGATION T. Yamamoto, T. Furukawa, I. Komura Japan Power Engineering and Inspection Corporation,

More information

POWER FACTOR IN THE DIGITAL AGE A N E N V I R O N M E N T A L P O T E N T I A L S W H I T E P A P E R. Power Quality For The Digital Age

POWER FACTOR IN THE DIGITAL AGE A N E N V I R O N M E N T A L P O T E N T I A L S W H I T E P A P E R. Power Quality For The Digital Age Power Quality For The Digital Age POWER FACTOR IN THE DIGITAL AGE A N E N V I R O N M E N T A L P O T E N T I A L S W H I T E P A P E R Introduction One method to measure the efficiency of the electrical

More information

INTEGRATION OF CURRENT METER MEASUREMENTS IN GENERAL FLOW CROSS SECTIONS

INTEGRATION OF CURRENT METER MEASUREMENTS IN GENERAL FLOW CROSS SECTIONS 10 th International Conference on Innovation in Hydraulic Efficiency Measurements September 16 19, 2014, Itajubá, Brasil INTEGRATION OF CURRENT METER MEASUREMENTS IN GENERAL FLOW CROSS SECTIONS T. Staubli

More information

FEATURES APPLICATIONS DESCRIPTION QUICK REFERENCE DATA. PILKOR components

FEATURES APPLICATIONS DESCRIPTION QUICK REFERENCE DATA. PILKOR components FEATURES Excellent anti-surge characteristics Stable characteristics to moisture resistance even in high resistance range. Good replacement for ceramic plate resistors. APPLICATIONS Telecommunication Industrial

More information

Design of an RF Photo-Gun (PHIN)

Design of an RF Photo-Gun (PHIN) Design of an RF Photo-Gun (PHIN) R. Roux 1, G. Bienvenu 1, C. Prevost 1, B. Mercier 1 1) CNRS-IN2P3-LAL, Orsay, France Abstract In this note we show the results of the RF simulations performed with a 2-D

More information

WCAP-FTXX Film Capacitors

WCAP-FTXX Film Capacitors A Dimensions: [mm] B Recommended hole pattern: [mm] D1 Electrical Properties: Properties Test conditions Value Unit Tol. Capacitance 1 V/ 1 khz ± 0.2 khz C 0.1000 µf ± 10% Rated voltage U R 310 V (AC)

More information

Approximate Analytical Calculation of the Skin Effect in Rectangular Wires

Approximate Analytical Calculation of the Skin Effect in Rectangular Wires Approimate Analytical Calculation of the Skin Effect in Rectangular Wires Dieter Gerling University of Federal Defense Munich, 85579 Neubiberg, Germany Dieter.Gerling@unibw.de Abstract- It is well-known

More information

Transmission Lines. Plane wave propagating in air Y unguided wave propagation. Transmission lines / waveguides Y. guided wave propagation

Transmission Lines. Plane wave propagating in air Y unguided wave propagation. Transmission lines / waveguides Y. guided wave propagation Transmission Lines Transmission lines and waveguides may be defined as devices used to guide energy from one point to another (from a source to a load). Transmission lines can consist of a set of conductors,

More information

Power System Engineering Prof. Debrapriya Das Department of Electrical Engineering Indian Institute of Technology, Kharagpur

Power System Engineering Prof. Debrapriya Das Department of Electrical Engineering Indian Institute of Technology, Kharagpur Power System Engineering Prof. Debrapriya Das Department of Electrical Engineering Indian Institute of Technology, Kharagpur Lecture - 01 Overhead Line Insulators So, welcome to this another course that

More information

TPC Suppressor Capacitors Classes X & Y A KYOCERA GROUP COMPANY

TPC Suppressor Capacitors Classes X & Y A KYOCERA GROUP COMPANY Suppressor Capacitors Classes X & Y A KYOCERA GROUP COMPANY Contents General Technical Information on Interference Suppression..... 2 Ordering Code......................................... 3 QX Series

More information