Optimally enhanced optical emission in laserinduced breakdown spectroscopy by combining spatial confinement and dual-pulse irradiation

Size: px
Start display at page:

Download "Optimally enhanced optical emission in laserinduced breakdown spectroscopy by combining spatial confinement and dual-pulse irradiation"

Transcription

1 University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Faculty Publications from the Department of Electrical and Computer Engineering Electrical & Computer Engineering, Department of Optimally enhanced optical emission in laserinduced breakdown spectroscopy by combining spatial confinement and dual-pulse irradiation L. B. Guo Huazhong University of Science and Technology, University of Nebraska-Lincoln B. Y. Zhang University of Nebraska-Lincoln X. N. He University of Nebraska-Lincoln C. M. Li Huazhong University of Science and Technology, University of Nebraska-Lincoln Y. S. Zhou University of Nebraska-Lincoln See next page for additional authors Follow this and additional works at: Part of the Computer Engineering Commons, and the Electrical and Computer Engineering Commons Guo, L. B.; Zhang, B. Y.; He, X. N.; Li, C. M.; Zhou, Y. S.; Wu, T.; Park, J. B.; Zeng, X. Y.; and Lu, Yongfeng, "Optimally enhanced optical emission in laser-induced breakdown spectroscopy by combining spatial confinement and dual-pulse irradiation" (2012). Faculty Publications from the Department of Electrical and Computer Engineering This Article is brought to you for free and open access by the Electrical & Computer Engineering, Department of at DigitalCommons@University of Nebraska - Lincoln. It has been accepted for inclusion in Faculty Publications from the Department of Electrical and Computer Engineering by an authorized administrator of DigitalCommons@University of Nebraska - Lincoln.

2 Authors L. B. Guo, B. Y. Zhang, X. N. He, C. M. Li, Y. S. Zhou, T. Wu, J. B. Park, X. Y. Zeng, and Yongfeng Lu This article is available at of Nebraska - Lincoln: electricalengineeringfacpub/232

3 Optimally enhanced optical emission in laserinduced breakdown spectroscopy by combining spatial confinement and dual-pulse irradiation L. B. Guo, 1,2 B. Y. Zhang, 2 X. N. He, 2 C. M. Li, 1,2 Y. S. Zhou, 2 T. Wu, 1 J. B. Park, 2 X. Y. Zeng, 1 and Y. F. Lu 2,* 1 Wuhan National Laboratory for Optoelectronics (WNLO), College of Optoelectronics Science and Engineering, Huazhong University of Science and Technology, Wuhan, Hubei , China 2 Department of Electrical Engineering, University of Nebraska-Lincoln, Lincoln, NE , USA *ylu2@unl.edu Abstract: In laser-induced breakdown spectroscopy (LIBS), a pair of aluminum-plate walls were used to spatially confine the plasmas produced in air by a first laser pulse (KrF excimer laser) from chromium (Cr) targets with a second laser pulse (Nd:YAG laser at 532 nm, 360 mj/pulse) introduced parallel to the sample surface to re-excite the plasmas. Optical emission enhancement was achieved by combing the spatial confinement and dual-pulse LIBS (DP-LIBS), and then optimized by adjusting the distance between the two walls and the interpulse delay time between both laser pulses. A significant enhancement factor of for the emission intensity of the Cr lines was obtained at an excimer laser fluence of 5.6 J/cm 2 using the combined spatial confinement and DP-LIBS, as compared with an enhancement factor of was obtained with DP-LIBS only. The enhancement mechanisms based on shock wave theory and reheating in DP- LIBS are discussed Optical Society of America OCIS codes: ( ) Spectroscopy, laser induced breakdown; ( ) Plasmas. References and links 1. L. J. Radziemski and D. A. Cremers, Laser Induced Plasma and Applications, (Marcel Dekker, New York, 1989). 2. U. Panne, R. E. Neuhauser, M. Theisen, H. Fink, and R. Niessner, Analysis of heavy metal aerosols on filters by laser-induced plasma spectroscopy, Spectrochim. Acta, B At. Spectrosc. 56(6), (2001). 3. L. M. Cabalín and J. J. Laserna, Surface stoichiometry of manganin coatings prepared by pulsed laser deposition as described by laser-induced breakdown spectrometry, Anal. Chem. 73(6), (2001). 4. A. C. Samuels, F. C. DeLucia, Jr., K. L. McNesby, and A. W. Miziolek, Laser-induced breakdown spectroscopy of bacterial spores, molds, pollens, and protein: initial studies of discrimination potential, Appl. Opt. 42(30), (2003). 5. N. J. McMillan, R. S. Harmon, F. C. De Lucia, and A. M. Miziolek, Laser-induced breakdown spectroscopy analysis of minerals: Carbonates and silicates, Spectrochim. Acta, B At. Spectrosc. 62B(12), (2007). 6. F. C. De Lucia, Jr., J. L. Gottfried, and A. W. Miziolek, Evaluation of femtosecond laser-induced breakdown spectroscopy for explosive residue detection, Opt. Express 17(2), (2009). 7. F. Hilbk-Kortenbruck, R. Noll, P. Wintjens, H. Falk, and C. Becker, Analysis of heavy metals in soils using laser-induced breakdown spectrometry combined with laser-induced fluorescence, Spectrochim. Acta, B At. Spectrosc. 56(6), (2001). 8. R. Noll, H. Bette, A. Brysch, M. Kraushaar, I. Mönch, L. Peter, and V. Sturm, Laser-induced breakdown spectrometry applications for production control and quality assurance in the steel industry, Spectrochim. Acta, B At. Spectrosc. 56(6), (2001). 9. X. K. Shen, J. Sun, H. Ling, and Y. F. Lu, Spatial confinement effects in laser-induced breakdown spectroscopy, Appl. Phys. Lett. 91(8), (2007). 10. J. Gruber, J. Heitz, H. Strasser, D. Bäuerle, and N. Ramaseder, Rapid in-situ analysis of liquid steel by laserinduced breakdown spectroscopy, Spectrochim. Acta, B At. Spectrosc. 56(6), (2001). 11. R. E. Neuhauser, U. Panne, and R. Niessner, Laser-induced plasma spectroscopy (LIPS): a versatile tool for monitoring heavy metal aerosols, Anal. Chim. Acta 392(1), (1999). 12. B. J. Marquardt, B. M. Cullum, T. J. Shaw, and S. M. Angel, Fiber optic probe for determining heavy metals in solids based on laser-induced plasmas, Proc. SPIE 3105, (1997). (C) 2012 OSA 16 January 2012 / Vol. 20, No. 2 / OPTICS EXPRESS 1436

4 13. C. M. Davies, H. H. Telle, and A. W. Williams, Remote in situ analytical spectroscopy and its applications in the nuclear industry, Anal. Bioanal. Chem. 355(7-8), (1996). 14. K. Y. Yamamoto, D. A. Cremers, M. J. Ferris, and L. E. Foster, Detection of metals in the environment using a portable laser-induced breakdown spectroscopy instrument, Appl. Spectrosc. 50(2), (1996). 15. D. Anglos, Laser-induced breakdown spectroscopy in art and archaeology, Appl. Spectrosc. 55(6), 186A 205A (2001). 16. M. Corsi, G. Cristoforetti, M. Hidalgo, S. Legnaioli, V. Palleschi, A. Salvetti, E. Tognoni, and C. Vallebona, Application of laser-induced breakdown spectroscopy technique to hair tissue mineral analysis, Appl. Opt. 42(30), (2003). 17. A. K. Knight, N. L. Scherbarth, D. A. Cremers, and M. J. Ferris, Characterization of laser-induced breakdown spectroscopy (LIBS) for application to space exploration, Appl. Spectrosc. 54(3), (2000). 18. J. Scaffidi, W. Pearman, J. C. Carter, and S. M. Angel, Observations in collinear femtosecond-nanosecond dualpulse laser-induced breakdown spectroscopy, Appl. Spectrosc. 60(1), (2006). 19. J. Scaffidi, J. Pender, W. Pearman, S. R. Goode, B. W. Colston, Jr., J. C. Carter, and S. M. Angel, Dual-pulse laser-induced breakdown spectroscopy with combinations of femtosecond and nanosecond laser pulses, Appl. Opt. 42(30), (2003). 20. R. E. Russo, X. L. Mao, J. J. Gonzalez, and S. S. Mao, Femtosecond laser ablation ICR-MS, J. Anal. At. Spectrom. 17(9), (2002). 21. X. K. Shen, H. Wang, Z. Q. Xie, Y. Gao, H. Ling, and Y. F. Lu, Detection of trace phosphorus in steel using laser-induced breakdown spectroscopy combined with laser-induced fluorescence, Appl. Opt. 48(13), (2009). 22. X. N. He, W. Hu, C. M. Li, L. B. Guo, and Y. F. Lu, Generation of high-temperature and low-density plasmas for improved spectral resolutions in laser-induced breakdown spectroscopy, Opt. Express 19(11), (2011). 23. A. M. Popov, F. Colao, and R. Fantoni, Enhancement of LIBS signal by spatially confining the laser-induced plasma, J. Anal. At. Spectrom. 24(5), (2009). 24. A. M. Popov, F. Colao, and R. Fantoni, Spatial confinement of laser-induced plasma to enhance LIBS sensitivity for trace elements determination in soils, J. Anal. At. Spectrom. 25(6), (2010). 25. L. B. Guo, C. M. Li, W. Hu, Y. S. Zhou, B. Y. Zhang, Z. X. Cai, X. Y. Zeng, and Y. F. Lu, Plasma confinement by hemispherical cavity in laser-induced breakdown spectroscopy, Appl. Phys. Lett. 98(13), (2011). 26. S. Singha, Z. Hu, and R. J. Gordon, Ablation and plasma emission produced by dual femtosecond laser pulses, J. Appl. Phys. 104(11), (2008). 27. J. Uebbing, J. Brust, W. Sdorra, F. Leis, and K. Niemax, Reheating of a laser-produced plasma by a second pulse laser, Appl. Spectrosc. 45(9), (1991). 28. A. De Giacomo, M. Dell Aglio, O. De Pascale, and M. Capitelli, From single pulse to double pulse ns-laserinduced breakdown spectroscopy under water: elemental analysis of aqueous solutions and submerged solid samples, Spectrochim. Acta, B At. Spectrosc. 62(8), (2007). 29. X. K. Shen, J. Sun, H. Ling, and Y. F. Lu, Spectroscopic study of laser-induced Al plasmas with cylindrical confinement, J. Appl. Phys. 102(9), (2007). 30. L. B. Guo, W. Hu, B. Y. Zhang, X. N. He, C. M. Li, Y. S. Zhou, Z. X. Cai, X. Y. Zeng, and Y. F. Lu, Enhancement of optical emission from laser-induced plasmas by combined spatial and magnetic confinement, Opt. Express 19(15), (2011). 31. D. K. Killinger, S. D. Allen, R. D. Waterbury, C. Stefano, and E. L. Dottery, Enhancement of Nd:YAG LIBS emission of a remote target using a simultaneous CO( 2) laser pulse, Opt. Express 15(20), (2007). 32. F. F. Chen, Introduction to Plasma Physics, (Plenum, New York, 1974). 1. Introduction Over the last few decades, laser-induced breakdown spectroscopy (LIBS) has been demonstrated as a promising and useful element analysis technique [1 8]. By focusing a powerful pulsed laser beam onto a sample surface, a hot luminous spark, forming a plasma, is generated, emission from the plasma used to identify and quantify within the sample. LIBS offers a simple and fast method of elemental analysis. The ability to form a plasma on unprocessed samples makes LIBS an amazingly versatile diagnostic tool [9 11]. It is one of the few techniques that can be used for non-contact elemental analysis, making LIBS uniquely suited to measurements of hazardous materials and materials in difficult-to-reach locations [12,13]. In recent years, LIBS has been successfully applied in many areas such as civilian and military environmental monitoring, cultural heritage analysis and characterization, biological and medical identification, and even space exploration [14 17]. Despite its obvious advantages, one of the major shortcomings of LIBS is its low detection sensitivity. Continuous studies have been made to improve the sensitivity of LIBS. These studies have led to investigations such as dual-pulse excitation and various plasma confinements [18 25]. The methods mentioned above have improved the detection sensitivity in LIBS though individual enhancement approaches. Further improvement of LIBS sensitivity will rely on (C) 2012 OSA 16 January 2012 / Vol. 20, No. 2 / OPTICS EXPRESS 1437

5 combination of these approaches. For example, dual-pulse LIBS (DP-LIBS) can be combined with spatial confinement of plasmas to effectively improve the sensitivity of LIBS. In DP- LIBS using orthogonal geometry, the first pulse is introduced onto the sample surface and the second pulse is focused parallel to the surface to reheat the plasma ablated by the first pulse. An increase in optical emission from the re-excited plasma can be observed [26 28]. At the same time, along with the generation and expansion of the laser-induced plasma in air by the first pulse, a shock wave is produced. The shock wave will be reflected back when it encounters some obstacles to compress the plasma plume [29]. The collision rate among the particles will be increased within the compressed plasma, resulting in an increase in the number of atoms at high-energy states, and hence, enhancing the emission intensity. Either dual-pulse excitation or plasma confinement was employed separately in previous studies. For instance, we [30] studied the enhancement of optical emission plasmas confined with the combination of spatial and magnetic confinements, resulting in a maximum enhancement factor of only 24 for pure metallic Cr sample. Killinger et al. [31] reported the enhancement of plasmas using a simultaneous CO 2 laser pulse, resulting in an increase of 60x for the Al atomic lines at 308 nm. In this study, our aim was to further improve the enhancement effects by the spatial confinement and dual-pulse in LIBS. Laser-induced plasmas with shock waves were produced and confined between a pair of parallel walls. The plasma plumes in LIBS were also investigated to study the evolution of the plasmas. 2. Experimental methods 2.1 Experiment setup Fig. 1. Schematic diagram of the experiment setup. The schematic diagram of the experimental setup of the spatially confined DP-LIBS is shown in Fig. 1. The experiments were performed in ambient air. A KrF excimer laser (Lambda Physik, Compex 205, wavelength: 248 nm, pulse duration: 23 ns) was used for the first laser pulse to generate plasmas. The laser beam was reflected both by a reflector (Reflector 1) and a dichroic mirror, respectively. The dichroic mirror is reflective to the laser beam but transparent to the other wavelengths studied. The laser beam was then focused onto a chromium (Cr) sample, which was sandwiched by a pair of aluminum (Al) parallel walls, by an UV-grade quartz lens (L1) of 15 cm focal length. The laser beam was slightly focused to a spot size of about mm 2 to reach a laser fluence of 5.6 J/cm 2. Plasma plumes with a size of several millimeters were generated between the walls. A Q-switched Nd:YAG laser operating at 532 nm (Continuum, Powerlite Precision II 8010, pulse duration of 6 ns) with a (C) 2012 OSA 16 January 2012 / Vol. 20, No. 2 / OPTICS EXPRESS 1438

6 pulse energy of 360 mj/pulse was introduced in parallel to the sample surfaces to reheat the plasmas generated by the first pulse. Both lasers were synchronized by a digital delay generator (Stanford Research System DG535, 5 ps delay resolution). The pulse repetition rate was set to 10 Hz. The Nd:YAG laser was focused by a convex lens (Lens 3 with f/10 cm focal length). The spatial position of the second pulse was adjusted by the Reflector 2 and Lens 3. The Nd:YAG laser was focused to a spot with a diameter of about 1 mm, around 2 mm above the sample surfaces. To avoid over ablation, the Cr target was mounted on a motorized translation stage, so that a new surface was exposed at each shot. 2.2 Spectral measurements The optical emission from plasmas was coupled to an optical fiber by Lens 1 and another UVgrade quartz lens (Lens 2 with f/6 cm focal length). The optical fiber, with a core diameter of 100 μm, was coupled to a spectrometer (Andor Tech., Shamrock 303i) with three gratings of 150, 600, and 2400 lines/mm. The grating of 2400 lines/mm, with a spectral resolution of 0.04 nm at 435 nm, was used in this study. A pixel intensified charge-coupled device (ICCD) (Andor Tech., istar, DH-712) was attached to the exit focal plane of the spectrometer. The gate delay and width of the ICCD was adjusted so that the spectra at different time delays after the laser pulse can be obtained. Plasma reheating with different interpulse delays was studied to obtain the optimal enhancement. The spectrometer started to acquire spectra at 3 μs after the first-pulse plasma. For all experiments, the excimer laser was fired first to produce a plasma. The Nd:YAG laser at 532 nm was fired second for plasma reheating. The purity of the Cr targets is 99.95%. Fig. 2. Time-integrated spectra from Cr targets with combined walls and dual pulse (solid curve), with dual-pulse laser (short dashed curve) and with excimer laser only (short dotted curve). Excimer laser fluence: 5.6 J/cm 2 ; Nd:YAG laser pulse energy: 360 mj/pulse. 3. Results and discussion 3.1 Time-integrated OES from the pure Cr targets The time-integrated emission spectra of the laser-induced Cr plasmas in a spectral range of nm were recorded with the presence of the walls in the DP-LIBS, (solid curves), DP- LIBS only (dashed curves), and excimer laser only (dotted curves), as shown in Fig. 2. The distance between the two flat walls was 13 mm. All the spectra were averaged over 30 shots to reduce the standard deviation. The time delay between the excimer laser and Nd:YAG laser was 0 μs. The gate delay and width of the ICCD detector was 3 and 30 μs, respectively. The emission intensities for the Cr atomic lines (425.44, , and nm) were all (C) 2012 OSA 16 January 2012 / Vol. 20, No. 2 / OPTICS EXPRESS 1439

7 obviously enhanced in the DP-LIBS with and without the presence of the walls, comparing to the excimer laser only. Enhancement factors of about 8 and 6 were obtained in the DP-LIBS with and without the walls. This clearly shows the difference cases with and without the walls in the DP-LIBS. The transition configuration for the three Cr atomic lines is 3d 5 ( 6 S)4s - 3d 5 ( 6 S)4p, where the 3d 5 ( 6 S)4s is the ground state of the Cr atom. Fig. 3. Emission intensity of Cr atomic lines ( nm) as a function of time delay, using both dual-pulse and walls (square dots and solid curve), using dual-pulse (circle dots and short dashed curve) and excimer only (triangle dots and short dotted curve), at excimer laser fluence of 5.6 J/cm 2, Nd:YAG laser: 360 mj/pulse. 3.2 Temporal evolution of emission intensities for Cr atomic lines from the pure Cr target A better understanding of the process of plasma emission enhancement with walls in the DP- LIBS was obtained. Figure 3 shows the temporal evolution of the emission intensities of the Cr atomic line ( nm) in DP-LIBS with the walls (square dots and solid curve), DP- LIBS without the walls (circle dots and short dashed curve), and LIBS using excimer laser only (triangle dots and short dotted). The time delay between the excimer laser and Nd:YAG laser was 9 μs. The ICCD started to acquire spectra from 3 μs after the first laser pulse and ended at 63 μs, with a gate width of 2 μs and a step of 2 μs. There were two significant enhancement peaks in the DP-LIBS with the walls. The two peaks occurred during the time periods from 7 to 17 μs and from 19 to 47 μs, while only one peak occurred from 7 to 17 μs in under DP-LIBS without the walls for comparison. The first peak was due to the enhancement by the reheating of Nd:YAG laser, whereas the second enhancement peak was due to the spatial confinement of the plasmas. Dual-pulse enhancement factors of about 12 (with aluminum walls) and 10 (without aluminum walls) have been acquired in DP-LIBS. (C) 2012 OSA 16 January 2012 / Vol. 20, No. 2 / OPTICS EXPRESS 1440

8 Fig. 4. Emission intensity for Cr atomic lines (All with nm) as a function of time delay. The distance between the walls are 11 mm, 13 mm, 15 mm, and 17 mm, at excimer laser fluence of 5.6 J/cm 2, Nd:YAG laser: 360 mj/pulse. 3.3 The optimization of the distance between the plate-walls To optimize the distance between the two walls in the DP-LIBS, Fig. 4 shows the evolutions of the emission intensity as a function of the time delay with different wall distances of 11 (square dots and curve), 13 (circle dots and curve), 15 (pentagon dots and curve), and 17 mm (triangle dots and curve), respectively. The intensity of LIBS using excimer laser only (diamond dots and curve) was also plotted for comparison. It is observed that the emission intensities were all enhanced although the enhancement factor depends on the wall distance. The maximum enhancement factor of the second peak decreased with a longer time delay as the wall distance increased. This is because the energy of the shock wave dissipates quickly with distance, and the traveling time increases as the wall distance increases. The best distance between the two flat walls is 11 mm. 3.4 The optimization of the interpulse delay time between the excimer laser and Nd:YAG laser After the optimization of the wall distance, the time delay between the excimer laser and Nd:YAG laser pulses was adjusted to further optimize the enhancement effects. Figure 5(a) shows the temporal evolution of DP-LIBS spectra with walls with an interpulse delay of 17 μs. The first spectrum was acquired with a delay of 3 μs after the first pulse and a gate width of 2 μs, and the following spectra were acquired with an increment of 2 μs. In Figs. 5(b) - 5(d), time-integrated LIBS spectra of Cr lines from reheating were compared with the firstpulse LIBS spectra to show the enhancement with different interpulse delays. As indicated in Figs. 5(b) - 5(d), after reheating of the plasmas, the intensity of LIBS spectra of Cr lines increased significantly compared with first-pulse LIBS spectra. Time-integrated LIBS spectra from the plasma of the Cr targets were acquired under first-pulse only condition [3 μs after plasma generation (dashed lines)] and with reheating [2 μs after second pulse (solid lines)] at different interpulse delays: Figs. 5(b) 17, (c) 25, and (d) 33 μs. It is shown that the strongest emission intensity of the Cr atomic lines appeared with an interpulse delay of 25 μs, significantly higher than shorter or longer interpulse delays. (C) 2012 OSA 16 January 2012 / Vol. 20, No. 2 / OPTICS EXPRESS 1441

9 Fig. 5. (a) Temporal evolution of DP-LIBS spectra with 50 μs interpulse delay; time-integrated LIBS spectra of plasmas from a Cr target under first-pulse only condition [3 μs after plasma generation (dashed lines)] and with reablation [2 μs after second pulse (solid lines)] at different interpulse delays of (b) 17, (c) 25, and (d) 33 μs. At excimer laser fluence of 5.6 J/cm 2, Nd:YAG laser: 360 J/pulse. Table 1. The enhancement factors of emission intensity for Cr atomic lines ( nm) in the DP-LIBS with and without walls Experiments Interpulse delay: (μs). ICCD gate delay: (μs). Start to acquire from the second pulse. ICCD gate width: (μs). Enhancement factor VS. Excimer laser only DP-LIBS only DP-LIBS with walls Therefore, the optimized interpulse delay time for DP-LIBS with confining walls is 25 μs. under the best interpulse delay of 25 μs, as is shown in Table 1, the Cr line ( nm) recorded by the spectrometer were acquired from 2 μs after the second-pulse plasma and with a gate width of 2 μs, the enhancement factor reached when adding walls in DP-LIBS, while the enhancement factor was only in DP-LIBS without confining walls. The reason can be explained by the combination of both spatial confinement of plasmas and dual-pulse reheating. When the plasma is generated by the first laser, the drastically increased pressure around the plasma induces a localized shock wave. The shock wave usually spreads out at a speed higher than the ordinary sound wave. When it reaches the walls, the shock wave is reflected by the parallel walls and travels back to the plasma center. Thus, the plasma is confined to a smaller size with increased emission intensity [32]. At the same time, the second laser pulse enters to reheat the plasma which is confined by the shock wave. As a result, the confined plasma is re-excited by the second laser pulse, leading to an increased number of excited atoms within the plasma, and consequently, temperature at the center of the plasma (C) 2012 OSA 16 January 2012 / Vol. 20, No. 2 / OPTICS EXPRESS 1442

10 increases. Therefore, the LIBS spectra of the Cr plasmas with combined spatial confinement of plasmas and dual-pulse LIBS can be further enhanced, resulting in a high sensitivity. 4. Conclusions In summary, the enhancement effects of optical emission in DP-LIBS with spatial confinement was studied. The significant enhancements in the atomic lines from Cr plasmas were observed. By the optimization of the distance between two Al walls and the interpulse delay time, the maximum enhancement factor for Cr atomic lines reached 168.6, as compared with an enhancement factor of for DP-LIBS without Al walls. It is obvious that the combined enhancement effects of confinement walls and dual-pulse in LIBS is much stronger than that of DP-LIBS only. The results of this study provide a new pathway in improving the sensitivity of LIBS. Acknowledgment This research work was financially supported by National Natural Science Foundation China (grant number ) and National Science Foundation (CMMI and CMMI ). (C) 2012 OSA 16 January 2012 / Vol. 20, No. 2 / OPTICS EXPRESS 1443

Enhancement of optical emission from laserinduced plasmas by combined spatial and magnetic confinement

Enhancement of optical emission from laserinduced plasmas by combined spatial and magnetic confinement University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Faculty Publications from the Department of Electrical and Computer Engineering Electrical & Computer Engineering, Department

More information

Accuracy improvement of quantitative analysis by spatial confinement in laser-induced breakdown spectroscopy

Accuracy improvement of quantitative analysis by spatial confinement in laser-induced breakdown spectroscopy University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Faculty Publications from the Department of Electrical and Computer Engineering Electrical & Computer Engineering, Department

More information

Generation of high-temperature and low-density plasmas for improved spectral resolutions in laser-induced breakdown spectroscopy

Generation of high-temperature and low-density plasmas for improved spectral resolutions in laser-induced breakdown spectroscopy Generation of high-temperature and low-density plasmas for improved spectral resolutions in laser-induced breakdown spectroscopy X.N. He, 1 W. Hu, 1 C.M. Li, 1,2 L.B. Guo, 1,2 and Y.F. Lu 1,* 1 Department

More information

The importance of longer wavelength reheating in dual-pulse laser-induced breakdown spectroscopy

The importance of longer wavelength reheating in dual-pulse laser-induced breakdown spectroscopy Appl Phys B (2012) 107:873 880 DOI 10.1007/s00340-012-4997-6 The importance of longer wavelength reheating in dual-pulse laser-induced breakdown spectroscopy R.W. Coons S.S. Harilal S.M. Hassan A. Hassanein

More information

Quantitative Analysis of Carbon Content in Bituminous Coal by Laser-Induced Breakdown Spectroscopy Using UV Laser Radiation

Quantitative Analysis of Carbon Content in Bituminous Coal by Laser-Induced Breakdown Spectroscopy Using UV Laser Radiation Quantitative Analysis of Carbon Content in Bituminous Coal by Laser-Induced Breakdown Spectroscopy Using UV Laser Radiation LI Xiongwei ( ) 1,3, MAO Xianglei ( ) 2, WANG Zhe ( ) 1, Richard E. RUSSO 2 1

More information

Outline. LIBS Background. LIBS Developments. LIBS Overview. Atomic Emission Spectroscopy

Outline. LIBS Background. LIBS Developments. LIBS Overview. Atomic Emission Spectroscopy Introduction to Laser Induced Breakdown Spectroscopy (LIBS) for Glass Analysis Module 4 José R. Almirall, Erica Cahoon, Maria Perez, Ben Naes, Emily Schenk and Cleon Barnett Department of Chemistry and

More information

JAAS Accepted Manuscript

JAAS Accepted Manuscript JAAS Accepted Manuscript This is an Accepted Manuscript, which has been through the Royal Society of Chemistry peer review process and has been accepted for publication. Accepted Manuscripts are published

More information

Title duration on laser ablation in liqui. Rightc 2009 Elsevier B.V. All rights res

Title duration on laser ablation in liqui.   Rightc 2009 Elsevier B.V. All rights res Title Spectral profile of atomic emission duration on laser ablation in liqui Author(s) Sakka, Tetsuo; Masai, Satoru; Fukam H. Citation Spectrochimica Acta Part B: 64(10): 981-985 Atomic Issue Date 2009-10

More information

Single pulse laser-induced breakdown spectroscopy of bulk aqueous solutions at oceanic pressures: interrelationship of gate delay and pulse energy

Single pulse laser-induced breakdown spectroscopy of bulk aqueous solutions at oceanic pressures: interrelationship of gate delay and pulse energy Single pulse laser-induced breakdown spectroscopy of bulk aqueous solutions at oceanic pressures: interrelationship of gate delay and pulse energy Anna P. M. Michel 1,2,3, * and Alan D. Chave 1 1 Department

More information

Measurements of plasma temperature and electron density in laser-induced copper plasma by time-resolved spectroscopy of neutral atom and ion emissions

Measurements of plasma temperature and electron density in laser-induced copper plasma by time-resolved spectroscopy of neutral atom and ion emissions PRAMANA c Indian Academy of Sciences Vol. 74, No. 6 journal of June 2010 physics pp. 983 993 Measurements of plasma temperature and electron density in laser-induced copper plasma by time-resolved spectroscopy

More information

A Fundamental Study of Laser-Induced Breakdown Spectroscopy Using Fiber Optics for Remote Measurements of Trace Metals

A Fundamental Study of Laser-Induced Breakdown Spectroscopy Using Fiber Optics for Remote Measurements of Trace Metals A Fundamental Study of Laser-Induced Breakdown Spectroscopy Using Fiber Optics for Remote Measurements of Trace Metals Scott R. Goode, Principal Investigator S. Michael Angel, Co-Principle Investigator

More information

Influence of laser energy on the electron temperature of a laser induced Mg plasma

Influence of laser energy on the electron temperature of a laser induced Mg plasma Appl. Phys. B (2017) 123:22 DOI 10.1007/s00340-016-6617-3 Influence of laser energy on the electron temperature of a laser induced Mg plasma Emmanuel Asamoah 1 Yao Hongbing 1 Received: 6 October 2016 /

More information

Chapter 4 LIBS system: Performance evaluation and optimization of conditions for quantitative analysis

Chapter 4 LIBS system: Performance evaluation and optimization of conditions for quantitative analysis LIBS system: Performance evaluation and optimization of conditions for quantitative analysis Journal of Instrumentation, 5, P4005, 2010 Pramana Journal of Physics, 75, 1145-1150, 2010 ABSTRACT The LIBS

More information

Time-Resolved Emission Spectroscopic Study of Laser-Induced Steel Plasmas

Time-Resolved Emission Spectroscopic Study of Laser-Induced Steel Plasmas Plasma Science and Technology, Vol.15, No.6, Jun. 2013 Time-Resolved Emission Spectroscopic Study of Laser-Induced Steel Plasmas M. L. SHAH, A. K. PULHANI, B. M. SURI, G. P. GUPTA Laser and Plasma Technology

More information

EFFECT OF LASER INTENSITY AND DYNAMICS OF PLASMA ON LASER INDUCED BREAKDOWN SPECTROSCOPY

EFFECT OF LASER INTENSITY AND DYNAMICS OF PLASMA ON LASER INDUCED BREAKDOWN SPECTROSCOPY EFFECT OF LASER INTENSITY AND DYNAMICS OF PLASMA ON LASER INDUCED BREAKDOWN SPECTROSCOPY V. N. Rai and Jagdish P. Singh, 3 Raja Ramanna Centre for Advanced Technology Indore-4503 (INDIA) vnrai@rrcat.gov.in

More information

International Journal of Scientific and Research Publications, Volume 5, Issue 5, May ISSN Osayuwamen Ogboghodo

International Journal of Scientific and Research Publications, Volume 5, Issue 5, May ISSN Osayuwamen Ogboghodo International Journal of Scientific and Research Publications, Volume 5, Issue 5, May 2015 1 Laser Induced Breakdown Spectroscopy for Identification & Quantification of Elemental Composition of Steel Structures:

More information

Measurements of egg shell plasma parameters using laser-induced breakdown spectroscopy

Measurements of egg shell plasma parameters using laser-induced breakdown spectroscopy PRAMANA c Indian Academy of Sciences Vol. 85, No. 1 journal of July 2015 physics pp. 105 114 Measurements of egg shell plasma parameters using laser-induced breakdown spectroscopy WENFENG LUO 1,, XIAOXIA

More information

Temporally resolved laser induced plasma diagnostics of single crystal silicon effects of ambient pressure

Temporally resolved laser induced plasma diagnostics of single crystal silicon effects of ambient pressure Temporally resolved laser induced plasma diagnostics of single crystal silicon effects of ambient pressure Cowpe, JS, Astin, JS, Pilkington, RD and Hill, AE http://dx.doi.org/10.1016/j.sab.2008.09.007

More information

THEORETICAL ASPECT OF ENHANCEMENT AND SATURATION IN EMISSION FROM LASER PRODUCED PLASMA

THEORETICAL ASPECT OF ENHANCEMENT AND SATURATION IN EMISSION FROM LASER PRODUCED PLASMA THEORETICAL ASPECT OF ENHANCEMENT AND SATURATION IN EMISSION FROM LASER PRODUCED PLASMA V. N. Rai Indus Synchrotron Utilization Division Raja Ramanna Centre for Advanced Technology Indore-4503 (INDIA)

More information

Time-resolved ultraviolet laser-induced breakdown spectroscopy for organic material analysis

Time-resolved ultraviolet laser-induced breakdown spectroscopy for organic material analysis Spectrochimica Acta Part B 62 (2007) 1329 1334 www.elsevier.com/locate/sab Time-resolved ultraviolet laser-induced breakdown spectroscopy for organic material analysis Matthieu Baudelet a, Myriam Boueri

More information

Elemental analysis by microwave-assisted laser-induced breakdown spectroscopy: Evaluation on ceramics

Elemental analysis by microwave-assisted laser-induced breakdown spectroscopy: Evaluation on ceramics PAPER www.rsc.org/jaas Journal of Analytical Atomic Spectrometry Elemental analysis by microwave-assisted laser-induced breakdown spectroscopy: Evaluation on ceramics Yuan Liu, Matthieu Baudelet* and Martin

More information

Design, construction and assessment of a field-deployable laser-induced breakdown spectrometer for remote elemental sensing

Design, construction and assessment of a field-deployable laser-induced breakdown spectrometer for remote elemental sensing Spectrochimica Acta Part B 61 (2006) 88 95 www.elsevier.com/locate/sab Design, construction and assessment of a field-deployable laser-induced breakdown spectrometer for remote elemental sensing Santiago

More information

Measurements of Deuterium Retention and Surface Elemental Composition with Double Pulse Laser Induced Breakdown Spectroscopy

Measurements of Deuterium Retention and Surface Elemental Composition with Double Pulse Laser Induced Breakdown Spectroscopy EUROFUSION CP(15)04/19 S. Almaviva et al. Measurements of Deuterium Retention and Surface Elemental Composition with Double Pulse Laser Induced Breakdown Spectroscopy (18th May 2015 22nd May 2015) Aix-en-Provence,

More information

Investigation of fundamental mechanisms related to ambient gas heating and hydrodynamics of laser-induced plasmas

Investigation of fundamental mechanisms related to ambient gas heating and hydrodynamics of laser-induced plasmas Investigation of fundamental mechanisms related to ambient gas heating and hydrodynamics of laser-induced plasmas P. J. Skrodzki Acknowledgements This work is supported by the DOE/NNSA Office of Nonproliferation

More information

Laser heating of noble gas droplet sprays: EUV source efficiency considerations

Laser heating of noble gas droplet sprays: EUV source efficiency considerations Laser heating of noble gas droplet sprays: EUV source efficiency considerations S.J. McNaught, J. Fan, E. Parra and H.M. Milchberg Institute for Physical Science and Technology University of Maryland College

More information

Development of advanced optical techniques for verification measurements Igor Jovanovic University of Michigan

Development of advanced optical techniques for verification measurements Igor Jovanovic University of Michigan Development of advanced optical techniques for verification measurements Igor Jovanovic University of Michigan Outline 1. Impetus and technical approach 2. Isotopic measurements from atomic and molecular

More information

Correction of Matrix Effects in Quantitative Elemental Analysis With Laser Ablation Optical Emission Spectrometry

Correction of Matrix Effects in Quantitative Elemental Analysis With Laser Ablation Optical Emission Spectrometry Correction of Matrix Effects in Quantitative Elemental Analysis With Laser Ablation Optical Emission Spectrometry C. CHALÉARD, P. MAUCHIEN*, N. ANDRE, J. UEBBING, J. L. LACOUR AND C. GEERTSEN Commissariat

More information

Spectrochimica Acta Part B

Spectrochimica Acta Part B Spectrochimica Acta Part B 64 (2009) 961 967 Contents lists available at ScienceDirect Spectrochimica Acta Part B journal homepage: www.elsevier.com/locate/sab Thermodynamic and spectroscopic properties

More information

Evaluation of laser-induced breakdown spectroscopy (LIBS) as a new in situ chemical sensing technique for the deep ocean

Evaluation of laser-induced breakdown spectroscopy (LIBS) as a new in situ chemical sensing technique for the deep ocean Evaluation of laser-induced breakdown spectroscopy (LIBS) as a new in situ chemical sensing technique for the deep ocean Anna P. M. Michel, Norman E. Farr, and Alan D. Chave Department of Applied Ocean

More information

Determination of Cl/C and Br/C ratios in pure organic solids using laser-induced plasma spectroscopy in near vacuum ultraviolet{

Determination of Cl/C and Br/C ratios in pure organic solids using laser-induced plasma spectroscopy in near vacuum ultraviolet{ Determination of Cl/C and Br/C ratios in pure organic solids using laser-induced plasma spectroscopy in near vacuum ultraviolet{ Saara Kaski,* Heikki Häkkänen and Jouko Korppi-Tommola Department of Chemistry,

More information

Controlling Graphene Ultrafast Hot Carrier Response from Metal-like. to Semiconductor-like by Electrostatic Gating

Controlling Graphene Ultrafast Hot Carrier Response from Metal-like. to Semiconductor-like by Electrostatic Gating Controlling Graphene Ultrafast Hot Carrier Response from Metal-like to Semiconductor-like by Electrostatic Gating S.-F. Shi, 1,2* T.-T. Tang, 1 B. Zeng, 1 L. Ju, 1 Q. Zhou, 1 A. Zettl, 1,2,3 F. Wang 1,2,3

More information

Remote Femtosecond Laser Induced Breakdown Spectroscopy (LIBS) in a Standoff Detection Regime

Remote Femtosecond Laser Induced Breakdown Spectroscopy (LIBS) in a Standoff Detection Regime Remote Femtosecond Laser Induced Breakdown Spectroscopy (LIBS) in a Standoff Detection Regime C.G. Brown a, R. Bernath a, M. Fisher a, M.C. Richardson a, M. Sigman b, R.A. Walters c, A. Miziolek d, H.

More information

Assessment of the Upper Particle Size Limit for Quantitative Analysis of Aerosols Using Laser-Induced Breakdown Spectroscopy

Assessment of the Upper Particle Size Limit for Quantitative Analysis of Aerosols Using Laser-Induced Breakdown Spectroscopy Anal. Chem. 2002, 74, 5450-5454 Assessment of the Upper Particle Size Limit for Quantitative Analysis of Aerosols Using Laser-Induced Breakdown Spectroscopy Jorge E. Carranza and David W. Hahn* Department

More information

OPTICAL DETECTION OF SLOW EXCITED NEUTRALS IN PLASMA- ASSISTED EXCIMER LASER ABLATION

OPTICAL DETECTION OF SLOW EXCITED NEUTRALS IN PLASMA- ASSISTED EXCIMER LASER ABLATION OPTICAL DETECTION OF SLOW EXCITED NEUTRALS IN PLASMA- ASSISTED EXCIMER LASER ABLATION P. MUKHERJEE, P. SAKTHIVEL AND S. WITANACHCHI Department of Physics, University of South Florida, Tampa, FL 33620,

More information

Chemical warfare detection by LIBS

Chemical warfare detection by LIBS Chemical warfare detection by LIBS Catherine GALLOU a, Agnès PAILLOUX a, Jean-Luc LACOUR a, Patrick MAUCHIEN a, Jean-Baptiste SIRVEN a, Evelyne VORS a, Elisabeth BOURIAH-COINDRE b a CEA, DEN, Department

More information

Laser Ablation for Chemical Analysis: 50 Years. Rick Russo Laser Damage Boulder, CA September 25, 2012

Laser Ablation for Chemical Analysis: 50 Years. Rick Russo Laser Damage Boulder, CA September 25, 2012 Laser Ablation for Chemical Analysis: 50 Years Rick Russo Lawrence Berkeley National Laboratory Applied Spectra, Inc 2012 Laser Damage Boulder, CA September 25, 2012 Laser Ablation for Chemical Analysis:

More information

Achievement of local thermodynamic equilibrium for ns laser-induced plasmas on aluminium sample at different wavelengths

Achievement of local thermodynamic equilibrium for ns laser-induced plasmas on aluminium sample at different wavelengths Journal of Physics: Conference Series OPEN ACCESS Achievement of local thermodynamic equilibrium for ns laser-induced plasmas on aluminium sample at different wavelengths To cite this article: Vincent

More information

Effect of applying static electric field on the physical parameters and dynamics of laser-induced plasma

Effect of applying static electric field on the physical parameters and dynamics of laser-induced plasma Journal of Advanced Research (2010) 1, 129 136 Cairo University Journal of Advanced Research ORIGINAL ARTICLE Effect of applying static electric field on the physical parameters and dynamics of laser-induced

More information

Comparative study of two new commercial echelle spectrometers equipped with intensified CCD for analysis of laser-induced breakdown spectroscopy

Comparative study of two new commercial echelle spectrometers equipped with intensified CCD for analysis of laser-induced breakdown spectroscopy Comparative study of two new commercial echelle spectrometers equipped with intensified CCD for analysis of laser-induced breakdown spectroscopy Mohamad Sabsabi, Vincent Detalle, Mohamed A. Harith, Walid

More information

LASER-INDUCED BREAKDOWN SPECTROSCOPY FOR REAL TIME AND ONLINE ELEMENTAL ANALYSIS

LASER-INDUCED BREAKDOWN SPECTROSCOPY FOR REAL TIME AND ONLINE ELEMENTAL ANALYSIS 1 LASER-INDUCED BREAKDOWN SPECTROSCOPY FOR REAL TIME AND ONLINE ELEMENTAL ANALYSIS Virendra N. Rai 1, Awadhesh K. Rai 2, Fang-Yu Yueh and J. P. Singh Diagnostic Instrumentation and Analysis Laboratory

More information

Analytical capability of LIBS method for carbon detection

Analytical capability of LIBS method for carbon detection JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS Vol. 12, No. 3, March 21, p. 668-673 Analytical capability of LIBS method for carbon detection T. CTVRTNICKOVA, M. P. MATEO, A. YAÑEZ, G. NICOLAS * Universidad

More information

Chamber Development Plan and Chamber Simulation Experiments

Chamber Development Plan and Chamber Simulation Experiments Chamber Development Plan and Chamber Simulation Experiments Farrokh Najmabadi HAPL Meeting November 12-13, 2001 Livermore, CA Electronic copy: http://aries.ucsd.edu/najmabadi/talks UCSD IFE Web Site: http://aries.ucsd.edu/ife

More information

Remote laser-induced plasma spectrometry for elemental analysis of samples of environmental interest

Remote laser-induced plasma spectrometry for elemental analysis of samples of environmental interest ARTICLE Remote laser-induced plasma spectrometry for elemental analysis of samples of environmental interest C. Lo pez-moreno, S. Palanco and J. J. Laserna* www.rsc.org/jaas Department of Analytical Chemistry,

More information

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source 3rd International EUVL Symposium NOVEMBER 1-4, 2004 Miyazaki, Japan Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source H. Tanaka, A. Matsumoto, K. Akinaga, A. Takahashi

More information

Study of the Matrix Effect on the Plasma Characterization of Heavy Elements in Soil Sediments using LIBS with a Portable Echelle Spectrometer

Study of the Matrix Effect on the Plasma Characterization of Heavy Elements in Soil Sediments using LIBS with a Portable Echelle Spectrometer Study of the Matrix Effect on the Plasma Characterization of Heavy Elements in Soil Sediments using LIBS with a Portable Echelle Spectrometer Walid Tawfik Y. Mohamed, and Abeer Askar National Inst. of

More information

Development of an Alternating Electric Field Accelerator for Laser-Ablation Plasma Acceleration

Development of an Alternating Electric Field Accelerator for Laser-Ablation Plasma Acceleration Development of an Alternating Electric Field Accelerator for Laser-Ablation Plasma Acceleration IEPC-2015-91125 Presented at Joint Conference of 30th International Symposium on Space Technology and Science

More information

Introduction to laser-based combustion diagnostics

Introduction to laser-based combustion diagnostics Introduction to laser-based combustion diagnostics (Lecture 1b) Lecture prepared for course in laser-based combustion diagnostics by Per-Erik Bengtsson and Joakim Bood Division of Combustion Physics at

More information

Remote Raman & Fluorescence Capabilities for Chemical Detection at University of Hawaii

Remote Raman & Fluorescence Capabilities for Chemical Detection at University of Hawaii Remote Raman & Fluorescence Capabilities for Chemical Detection at University of Hawaii Anupam Misra Shiv Sharma HIGP, SOEST, Univ. of Hawaii * Daytime Operation * Long Detection Range (no sample collection)

More information

EMISSION SPECTRA OF LASER-INDUCED PLASMAS AT THE ELEMENTAL ANALYSIS OF SOLIDS: MEASUREMENT AND MODELING RESULTS

EMISSION SPECTRA OF LASER-INDUCED PLASMAS AT THE ELEMENTAL ANALYSIS OF SOLIDS: MEASUREMENT AND MODELING RESULTS VI Serbian-Belarusian Symp. on Phys. and Diagn. of Lab. & Astrophys. Plasma, Belgrade, Serbia, 22-25 August 2006 eds. M. Ćuk, M.S. Dimitrijević, J. Purić, N. Milovanović Publ. Astron. Obs. Belgrade No.

More information

Analysis by laser-induced breakdown spectroscopy of complex solids, liquids, and powders with an echelle spectrometer

Analysis by laser-induced breakdown spectroscopy of complex solids, liquids, and powders with an echelle spectrometer Analysis by laser-induced breakdown spectroscopy of complex solids, liquids, and powders with an echelle spectrometer Pascal Fichet, Denis Menut, René Brennetot, Evelyne Vors, and Annie Rivoallan One of

More information

Comparisons between LIBS and ICP/OES

Comparisons between LIBS and ICP/OES Anal Bioanal Chem (26) 385: 338 344 DOI 1.17/s216-6-384-7 ORIGINAL PAPER P. Fichet. M. Tabarant. B. Salle. C. Gautier Comparisons between LIBS and ICP/OES Received: 2 January 26 / Revised: 17 February

More information

Work Piece Identification based on Plasma Emission Analysis for Customized Laser Processing

Work Piece Identification based on Plasma Emission Analysis for Customized Laser Processing Work Piece Identification based on Plasma Emission Analysis for Customized Laser Processing David DIEGO-VALLEJO *1,2, David ASHKENASI 3 and Hans Joachim EICHLER 1 1 Technische Universität Berlin, Institut

More information

Differential Spectral Imaging of the CN Violet Band in Laser-Induced Plasmas on TNT Simulant Molecules

Differential Spectral Imaging of the CN Violet Band in Laser-Induced Plasmas on TNT Simulant Molecules Publications 214 Differential Spectral Imaging of the CN Violet Band in Laser-Induced Plasmas on TNT Simulant Molecules J. Merten Arkansas State University - Main Campus M. Jones Anton Paar S. Hoke Arkansas

More information

Underwater Raman Sensor for Detecting High Explosives and Homemade Explosives (HMEs)

Underwater Raman Sensor for Detecting High Explosives and Homemade Explosives (HMEs) Underwater Raman Sensor for Detecting High Explosives and Homemade Explosives (HMEs) Shiv K. Sharma* Hawaii Institute of Geophysics & Planetology, University of Hawaii (UH) at Manoa, Honolulu, Hawaii,

More information

Approach to Detection in Laser-Induced Breakdown Spectroscopy

Approach to Detection in Laser-Induced Breakdown Spectroscopy Anal. Chem. 2007, 79, 4419-4426 Approach to Detection in Laser-Induced Breakdown Spectroscopy M. Mueller,*, I. B. Gornushkin, S. Florek, D. Mory, and U. Panne Federal Institute for Materials Research and

More information

Glass surface modification using Nd:YAG laser in SF 6 atmospheres

Glass surface modification using Nd:YAG laser in SF 6 atmospheres J Theor Appl Phys (2015) 9:135 140 DOI 10.1007/s40094-015-0171-y RESEARCH Glass surface modification using Nd:YAG laser in SF 6 atmospheres H. R. Dehghanpour P. Parvin Received: 2 September 2014 / Accepted:

More information

BRET C. WINDOM UNIVERSITY OF FLORIDA

BRET C. WINDOM UNIVERSITY OF FLORIDA IMPLEMENTATION OF AERODYNAMIC FOCUSING AND A DUAL-PULSE CONFIGURATION TO IMPROVE LASER-INDUCED BREAKDOWN SPECTROSCOPY AEROSOL PARTICLE SAMPLING RATES AND ANALYTE RESPONSE By BRET C. WINDOM A THESIS PRESENTED

More information

UNDERWATER LIBS INVESTIGATIONS SETUP FOR METALS IDENTIFICATION

UNDERWATER LIBS INVESTIGATIONS SETUP FOR METALS IDENTIFICATION U.P.B. Sci. Bull., Series A, Vol. 72, Iss. 4, 2010 ISSN 1223-7027 UNDERWATER LIBS INVESTIGATIONS SETUP FOR METALS IDENTIFICATION Monica SIMILEANU 1, Roxana RADVAN 2, Niculae PUSCAS 3 LIBS este o tehnică

More information

Richard Miles and Arthur Dogariu. Mechanical and Aerospace Engineering Princeton University, Princeton, NJ 08540, USA

Richard Miles and Arthur Dogariu. Mechanical and Aerospace Engineering Princeton University, Princeton, NJ 08540, USA Richard Miles and Arthur Dogariu Mechanical and Aerospace Engineering Princeton University, Princeton, NJ 08540, USA Workshop on Oxygen Plasma Kinetics Sept 20, 2016 Financial support: ONR and MetroLaser

More information

Laser matter interaction

Laser matter interaction Laser matter interaction PH413 Lasers & Photonics Lecture 26 Why study laser matter interaction? Fundamental physics Chemical analysis Material processing Biomedical applications Deposition of novel structures

More information

Oceanic Applications of Laser Induced Breakdown Spectroscopy: Laboratory Validation

Oceanic Applications of Laser Induced Breakdown Spectroscopy: Laboratory Validation Oceanic Applications of Laser Induced Breakdown Spectroscopy: Laboratory Validation Anna PM Michel, Marion J. Lawrence-Snyder, S. Michael Angel, and Alan D. Chave Massachusetts Institute of Technology

More information

No. 9 Experimental study on the chirped structure of the construct the early time spectra. [14;15] The prevailing account of the chirped struct

No. 9 Experimental study on the chirped structure of the construct the early time spectra. [14;15] The prevailing account of the chirped struct Vol 12 No 9, September 2003 cfl 2003 Chin. Phys. Soc. 1009-1963/2003/12(09)/0986-06 Chinese Physics and IOP Publishing Ltd Experimental study on the chirped structure of the white-light continuum generation

More information

Self-channeling of Femtosecond Laser Pulses for Rapid and Efficient Standoff Detection of Energetic Materials

Self-channeling of Femtosecond Laser Pulses for Rapid and Efficient Standoff Detection of Energetic Materials Self-channeling of Femtosecond Laser Pulses for Rapid and Efficient Standoff Detection of Energetic Materials Matthieu Baudelet, Martin Richardson, Townes laser Institute, CREOL, University of Central

More information

MICHAEL J. WITTE 1 AND CHRISTIAN G. PARIGGER 1,a

MICHAEL J. WITTE 1 AND CHRISTIAN G. PARIGGER 1,a I R A M P Measurement and Analysis of Carbon Swan Spectra Following Laser-induced Optical Breakdown International in AirScience Press ISSN: 2229-3159 4(1), June 2013, pp. 63-67 Measurement and Analysis

More information

The role of laser wavelength on plasma generation and expansion of ablation plumes in air

The role of laser wavelength on plasma generation and expansion of ablation plumes in air JOURNAL OF APPLIED PHYSICS 113, 143305 (2013) The role of laser wavelength on plasma generation and expansion of ablation plumes in air A. E. Hussein, 1,2 P. K. Diwakar, 1 S. S. Harilal, 1 and A. Hassanein

More information

Remote Femtosecond Laser Induced Breakdown Spectroscopy (LIBS) in a Standoff Detection Regime

Remote Femtosecond Laser Induced Breakdown Spectroscopy (LIBS) in a Standoff Detection Regime Remote Femtosecond Laser Induced Breakdown Spectroscopy (LIBS) in a Standoff Detection Regime C.G. Brown a, R. Bernath a, M. Fisher a, M.C. Richardson a, M. Sigman b, R.A. Walters c, A. Miziolek d, H.

More information

Nanosecond Broadband Spectroscopy For Laser-Driven Compression Experiments

Nanosecond Broadband Spectroscopy For Laser-Driven Compression Experiments Nanosecond Broadband Spectroscopy For Laser-Driven Compression Experiments Dylan K. Spaulding, R. Jeanloz Department of Earth and Planetary Science, University of California, Berkeley307 McCone Hall, Berkeley,

More information

LASER-INDUCED BREAKDOWN SPECTROSCOPY INFRARED EMISSION FROM INORGANIC AND ORGANIC SUBSTANCES

LASER-INDUCED BREAKDOWN SPECTROSCOPY INFRARED EMISSION FROM INORGANIC AND ORGANIC SUBSTANCES LASER-INDUCED BREAKDOWN SPECTROSCOPY INFRARED EMISSION FROM INORGANIC AND ORGANIC SUBSTANCES C.S-C. Yang Battelle Eastern Science and Technology Center Aberdeen, MD 21001 E. Brown and U. Hommerich Department

More information

LIBSlab ANALYZERS ANALYZERS

LIBSlab ANALYZERS ANALYZERS ANALYZERS ANALYZERS Chemical multi-elemental analysis with LIBS in modular benchtop design LIBSlab LIBSpector compact sample chamber for the LIBS analysis of solid, liquid and gaseous samples. Sample chamber

More information

The application of spectrum standardization method for carbon analysis in coal using laser-induced breakdown spectroscopy

The application of spectrum standardization method for carbon analysis in coal using laser-induced breakdown spectroscopy The application of spectrum standardization method for carbon analysis in coal using laser-induced breakdown spectroscopy Xiongwei Li, Zhe Wang *, Yangting Fu, Zheng Li, Jianming Liu, Weidou Ni State Key

More information

Laser-produced extreme ultraviolet (EUV) light source plasma for the next generation lithography application

Laser-produced extreme ultraviolet (EUV) light source plasma for the next generation lithography application Laser-produced extreme ultraviolet (EUV) light source plasma for the next generation lithography application EUV light source plasma Tin icrodroplet Main pulse (CO2 laser pulse) Pre-pulse (Nd:YAG laser

More information

Multi-diagnostic comparison of femtosecond and nanosecond pulsed laser plasmas

Multi-diagnostic comparison of femtosecond and nanosecond pulsed laser plasmas JOURNAL OF APPLIED PHYSICS VOLUME 92, NUMBER 5 1 SEPTEMBER 2002 Multi-diagnostic comparison of femtosecond and nanosecond pulsed laser plasmas Z. Zhang, a) P. A. VanRompay, J. A. Nees, and P. P. Pronko

More information

Spectroscopic Studies of Soft X-Ray Emission from Gadolinium Plasmas

Spectroscopic Studies of Soft X-Ray Emission from Gadolinium Plasmas I. Kambali, G. Atom O Sullivan Indonesia / Atom Vol. Indonesia 4 No. 2 (24) Vol. 47 No. - 2 (24) 7 - Spectroscopic Studies of Soft X-Ray Emission from Gadolinium Plasmas I. Kambali * and G. O Sullivan

More information

Title. Author(s)Takeuchi, Masato; Sasaki, Koichi. CitationApplied physics A: Materials science & processing, 1. Issue Date Doc URL.

Title. Author(s)Takeuchi, Masato; Sasaki, Koichi. CitationApplied physics A: Materials science & processing, 1. Issue Date Doc URL. Title Spectrum of laser light scattered by nanoparticles i Author(s)Takeuchi, Masato; Sasaki, Koichi CitationApplied physics A: Materials science & processing, 1 Issue Date 216-4 Doc URL http://hdl.handle.net/211/64912

More information

Laser-Induced Breakdown Spectroscopy: Application to Nuclear Waste Management Seong Yong Oh, Fang Yu Yueh, Jagdish P.

Laser-Induced Breakdown Spectroscopy: Application to Nuclear Waste Management Seong Yong Oh, Fang Yu Yueh, Jagdish P. Laser-Induced Breakdown Spectroscopy: Application to Nuclear Waste Management -- 9166 Seong Yong Oh, Fang Yu Yueh, Jagdish P. Singh* Institute for Clean Energy Technology Mississippi State University,

More information

Behavior and Energy States of Photogenerated Charge Carriers

Behavior and Energy States of Photogenerated Charge Carriers S1 Behavior and Energy States of Photogenerated Charge Carriers on Pt- or CoOx-loaded LaTiO2N Photocatalysts: Time-resolved Visible to mid-ir Absorption Study Akira Yamakata, 1,2* Masayuki Kawaguchi, 1

More information

Answers to questions on exam in laser-based combustion diagnostics on March 10, 2006

Answers to questions on exam in laser-based combustion diagnostics on March 10, 2006 Answers to questions on exam in laser-based combustion diagnostics on March 10, 2006 1. Examples of advantages and disadvantages with laser-based combustion diagnostic techniques: + Nonintrusive + High

More information

DISCHARGE CHARACTERISTICS OF A LASER-ASSISTED PLASMA THRUSTER

DISCHARGE CHARACTERISTICS OF A LASER-ASSISTED PLASMA THRUSTER DISCHARGE CHARACTERISTICS OF A LASER-ASSISTED PLASMA THRUSTER Hideyuki Horisawa *, Masatoshi Kawakami *, Wun-Wei Lin *, Akira Igari *, and Itsuro Kimura # * Department of Aeronautics and Astronautics,

More information

Dynamics of carbon and tungsten colliding plumes

Dynamics of carbon and tungsten colliding plumes Dynamics of carbon and tungsten colliding plumes H. Sato 2,Y. Hirooka 1, K. A. Tanaka 2 and the Reactor Eng. Group 2 1) National Institute for Fusion Science 2) Osaka University 2009,Oct 8 th -9 th TITAN

More information

Highly Efficient and Anomalous Charge Transfer in van der Waals Trilayer Semiconductors

Highly Efficient and Anomalous Charge Transfer in van der Waals Trilayer Semiconductors Highly Efficient and Anomalous Charge Transfer in van der Waals Trilayer Semiconductors Frank Ceballos 1, Ming-Gang Ju 2 Samuel D. Lane 1, Xiao Cheng Zeng 2 & Hui Zhao 1 1 Department of Physics and Astronomy,

More information

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and education use, including for instruction at the authors institution

More information

Optimization of laser-produced plasma light sources for EUV lithography

Optimization of laser-produced plasma light sources for EUV lithography page 1 of 17 Optimization of laser-produced plasma light sources for EUV lithography M. S. Tillack and Y. Tao 1 University of California, San Diego Center for Energy Research 1 Currently at Cymer Inc.

More information

Assessment of Threshold for Nonlinear Effects in Ibsen Transmission Gratings

Assessment of Threshold for Nonlinear Effects in Ibsen Transmission Gratings Assessment of Threshold for Nonlinear Effects in Ibsen Transmission Gratings Temple University 13th & Norris Street Philadelphia, PA 19122 T: 1-215-204-1052 contact: johanan@temple.edu http://www.temple.edu/capr/

More information

Mandatory Assignment 2013 INF-GEO4310

Mandatory Assignment 2013 INF-GEO4310 Mandatory Assignment 2013 INF-GEO4310 Deadline for submission: 12-Nov-2013 e-mail the answers in one pdf file to vikashp@ifi.uio.no Part I: Multiple choice questions Multiple choice geometrical optics

More information

DIAGNOSTIC OF A LASER-INDUCED OPTICAL BREAKDOWN BASED ON HALF-WIDTH AT HALF AREA OF H LINES , H , AND H

DIAGNOSTIC OF A LASER-INDUCED OPTICAL BREAKDOWN BASED ON HALF-WIDTH AT HALF AREA OF H LINES , H , AND H INTERNATIONAL REVIEW OF ATOMIC AND MOLECULAR PHYSICS (IRAMP) Volume 1, No. 2, July-December 2010, pp. 129-136, International Science Press, ISSN: 2229-3159 RESEARCH ARTICLE DIAGNOSTIC OF A LASER-INDUCED

More information

Plume expansion and stoichiometry in the growth of multi-component thin films using dual-laser ablation

Plume expansion and stoichiometry in the growth of multi-component thin films using dual-laser ablation Ž. Applied Surface Science 127 129 1998 620 625 Plume expansion and stoichiometry in the growth of multi-component thin films using dual-laser ablation Pritish Mukherjee 1, John B. Cuff, Sarath Witanachchi

More information

Spatially and temporally resolved temperature measurements of plasma generated in percussion drilling with a diode-pumped Nd:YAG laser

Spatially and temporally resolved temperature measurements of plasma generated in percussion drilling with a diode-pumped Nd:YAG laser JOURNAL OF APPLIED PHYSICS VOLUME 84, NUMBER 8 15 OCTOBER 1998 Spatially and temporally resolved temperature measurements of plasma generated in percussion drilling with a diode-pumped Nd:YAG laser M.

More information

MAPPING OF ATOMIC NITROGEN IN SINGLE FILAMENTS OF A BARRIER DISCHARGE MEASURED BY TWO PHOTON FLUORESCENCE SPECTROSCOPY (TALIF)

MAPPING OF ATOMIC NITROGEN IN SINGLE FILAMENTS OF A BARRIER DISCHARGE MEASURED BY TWO PHOTON FLUORESCENCE SPECTROSCOPY (TALIF) MAPPING OF ATOMIC NITROGEN IN SINGLE FILAMENTS OF A BARRIER DISCHARGE MEASURED BY TWO PHOTON FLUORESCENCE SPECTROSCOPY (TALIF) C. LUKAS, M. SPAAN, V. SCHULZ VON DER GATHEN, H. F. DÖBELE Institut für Laser

More information

dating of geological samples by laser ablation ICPMS

dating of geological samples by laser ablation ICPMS U-Th-Pb dating of geological samples by laser ablation ICPMS Winter Conference on Plasma Spectrochemistry Fort Lauderdale, Florida, January 3, 2004 Short course ST-19 Jan Košler 1 and Mike Tubrett 2 1.

More information

LASER ABLATION SYNTHESIS OF ZINC OXIDE CLUSTERS:

LASER ABLATION SYNTHESIS OF ZINC OXIDE CLUSTERS: LASER ABLATION SYNTHESIS OF ZINC OXIDE CLUSTERS: A NEW FAMILY OF FULLERENES? Alexander V. Bulgakov a, Igor Ozerov b, Wladimir Marine b a Institute of Thermophysics, Prospect Lavrentyev 1, 630090 Novosibirsk,

More information

Femtosecond laser rapid fabrication of large-area rose-like micropatterns on freestanding flexible graphene films

Femtosecond laser rapid fabrication of large-area rose-like micropatterns on freestanding flexible graphene films Femtosecond laser rapid fabrication of large-area rose-like micropatterns on freestanding flexible graphene films Xuesong Shi, 1 Xin Li, 1 Lan Jiang, 1,* Liangti Qu, 2 Yang Zhao, 2 Peng Ran, 1 Qingsong

More information

Magnetic Assisted Laser Micromachining for Highly Reflective Metals

Magnetic Assisted Laser Micromachining for Highly Reflective Metals Magnetic Assisted Laser Micromachining for Highly Reflective Metals Yuan-Jen Chang, Chia-Lung Kuo, and Nai-Yu Wang Department of Mechanical Engineering, National Yunlin University of Science and Technology,

More information

Magnetic fields applied to laser-generated plasma to enhance the ion yield acceleration

Magnetic fields applied to laser-generated plasma to enhance the ion yield acceleration Magnetic fields applied to laser-generated plasma to enhance the ion yield acceleration L. Torrisi, G. Costa, and G. Ceccio Dipartimento di Scienze Fisiche MIFT, Università di Messina, V.le F.S. D Alcontres

More information

HYPER-RAYLEIGH SCATTERING AND SURFACE-ENHANCED RAMAN SCATTERING STUDIES OF PLATINUM NANOPARTICLE SUSPENSIONS

HYPER-RAYLEIGH SCATTERING AND SURFACE-ENHANCED RAMAN SCATTERING STUDIES OF PLATINUM NANOPARTICLE SUSPENSIONS www.arpapress.com/volumes/vol19issue1/ijrras_19_1_06.pdf HYPER-RAYLEIGH SCATTERING AND SURFACE-ENHANCED RAMAN SCATTERING STUDIES OF PLATINUM NANOPARTICLE SUSPENSIONS M. Eslamifar Physics Department, BehbahanKhatamAl-Anbia

More information

Direct measurement of spectral phase for ultrashort laser pulses

Direct measurement of spectral phase for ultrashort laser pulses Direct measurement of spectral phase for ultrashort laser pulses Vadim V. Lozovoy, 1 Bingwei Xu, 1 Yves Coello, 1 and Marcos Dantus 1,2,* 1 Department of Chemistry, Michigan State University 2 Department

More information

Electron Density Measurements of Argon Surface-Wave Discharges

Electron Density Measurements of Argon Surface-Wave Discharges Plasma Chemistry and Plasma Processing, Vol. 5, No. 3, 1985 Electron Density Measurements of Argon Surface-Wave Discharges M. Brake, 1'2 J. Rogers, 1'3 M. Peters, 1 J. Asmussen, 1 and R. Kerber 1 Received

More information

GA A25842 STUDY OF NON-LTE SPECTRA DEPENDENCE ON TARGET MASS IN SHORT PULSE LASER EXPERIMENTS

GA A25842 STUDY OF NON-LTE SPECTRA DEPENDENCE ON TARGET MASS IN SHORT PULSE LASER EXPERIMENTS GA A25842 STUDY OF NON-LTE SPECTRA DEPENDENCE ON TARGET MASS IN SHORT PULSE LASER EXPERIMENTS by C.A. BACK, P. AUDBERT, S.D. BATON, S.BASTIANI-CECCOTTI, P. GUILLOU, L. LECHERBOURG, B. BARBREL, E. GAUCI,

More information

Portable LIBS system for determining the composition of multilayer structures on objects of cultural value

Portable LIBS system for determining the composition of multilayer structures on objects of cultural value Journal of Physics: Conference Series Portable LIBS system for determining the composition of multilayer structures on objects of cultural value To cite this article: Lesther Moreira Osorio et al 211 J.

More information

Spectroscopic Diagnostics of Laser Plasma Plume of Aluminum

Spectroscopic Diagnostics of Laser Plasma Plume of Aluminum Optics 2015; 4(5): 31-36 Published online October 8, 2015 (http://www.sciencepublishinggroup.com/j/optics) doi: 10.11648/j.optics.20150405.11 ISSN: 2328-7780 (Print); ISSN: 2328-7810 (Online) Spectroscopic

More information

Growth and collapse of laser-induced bubbles in glycerol water mixtures

Growth and collapse of laser-induced bubbles in glycerol water mixtures Vol 17 No 7, July 2008 c 2008 Chin. Phys. Soc. 1674-1056/2008/17(07)/2574-06 Chinese Physics B and IOP Publishing Ltd Growth and collapse of laser-induced bubbles in glycerol water mixtures Liu Xiu-Mei(

More information