Enhanced odour profiling of strawberries using TD GC TOF MS

Size: px
Start display at page:

Download "Enhanced odour profiling of strawberries using TD GC TOF MS"

Transcription

1 Application Released: April 213 Application Note 515 Enhanced odour profiling of strawberries using TD GC TOF MS Summary This Application Note describes the application of a BenchTOF time-of-flight mass spectrometer to enhance the detection of trace-level components in the headspace gas above fresh strawberries. At the same time, the versatility of TargetView compound identification software is demonstrated by an all-component search against NIST and by a targeted search for various odour-active sulfur compounds. Introduction Food aroma profiles typically contain components at a wide range of concentrations, though very often some of the most odour-active components are only present at trace levels. In such situations a highly sensitive detector is essential to maximise the prospects for analyte detection and identification. Background to BenchTOF instruments Markes BenchTOF time-of-flight mass spectrometers are ideally suited for the analysis of such samples, the following three features being of particular importance: Sensitivity: Highly efficient direct-extraction technology allows BenchTOF instruments to acquire full-range spectra with SIM-like sensitivity, allowing them to reliably detect trace-level analytes in a single run, which would be difficult or impossible on a quadrupole system. Spectral quality: The reference-quality spectra produced by BenchTOF are a close match for those in commercial libraries such as NIST or Wiley. This enables quick and confident matching of both targets and unknowns. Speed: The ability to record full-range mass spectral information to extremely high densities (1, transient spectral accumulations per second) enables advanced spectral deconvolution and data-mining algorithms to extract maximum information from weak, matrix-masked signals. Background to TargetView The advantages of BenchTOF instruments are enhanced by TargetView, an innovative post-run data processing package that allows accurate and automated identification of trace compounds in complex GC MS profiles. TargetView uses sophisticated algorithms to eliminate background interference and deconvolve co-eluting components into individual analyte peaks. The mass spectra produced for each deconvolved component can then be rapidly matched against library spectra using advanced chemometric techniques, which allow both target and unknown compounds to be identified confidently, even at trace levels. Total ion chromatographic (TIC) profiles can either be searched against a target library (a target search ), or screened against the full NIST library (an all-component search ). TargetView is easy to learn, simple to operate, and compatible with GC MS file types from most major vendors. Experimental The extraction and analysis process is depicted schematically in Figure 1. Note that the microchamber system is able to accommodate whole strawberries, which would be not be possible with a standard 2 ml headspace vial. Sampling: Instrument: Chambers: Micro-Chamber/Thermal Extractor (Markes International) (six-chamber version) Inert-coated stainless-steel, 44 ml capacity Chamber temp.: 4 C Equilibration: 5 ml/min of dry nitrogen for 1 min Sampling flow: 2 min using 5 ml/min dry nitrogen Headspace volume: 1 ml sampled Sorbent tubes: Quartz wool Tenax TA SulfiCarb Formerly ALMSCO Application Note 15.

2 Page 2 Place strawberry in microchamber pot and weigh sample. Load pot into the Micro-Chamber/ Thermal Extractor. Attach sorbent tube, pass heated N 2 into the chamber, and collect released vapours. Load tube into the TD-1 automated thermal desorber and......analyse vapours by GC TOF MS. Identify compounds using TargetView software. Figure 1: Flow chart showing the process used to sample and identify the volatile compounds released from whole strawberries. TD: Instrument: TD-1 (Markes International) Flow path temp.: 16 C Focusing trap: Material Emissions Trap Dry-purge: 2 min, 2 ml/min flow Primary (tube) desorption: 12 C for 5 min, then 26 C for 5 min; 4 ml/min trap flow Pre-trap-fire purge: 2 min; 5 ml/min trap flow; 2 ml/min split flow Secondary (trap) desorption: TD split: Trap low: 25 C; trap high: 3 C; heating rate: 24 C/s; hold time: 5. min; split flow: 2 ml/min 21:1 outlet split GC MS System 1: GC: Column: Rtx-5MS 6 m.25 mm.5 µm Carrier: He, constant flow 1. ml/min Temp. programme: 4 C (5. min), 1 C/min to 3 C (5. min) Total run time: 36. min TOF MS: Instrument: BenchTOF (Markes International) Ion source: 28 C Transfer line: 2 C Mass range: m/z Data rate: 2 Hz (5 spectral accumulations per data point) Filament voltage: 1.6 V GC MS System 2: GC: Column: DB-5, 6 m.25 mm.5 µm Carrier: He, constant flow 1. ml/min Temp. programme: 4 C (5. min), 1 C/min to 3 C (5. min) Total run time: 36. min Quadrupole MS: Ion source: 23 C Quadrupole: 15 C Transfer line: 28 C Mass range: m/z Data rate: 5 Hz Gain factor: 1 Results and discussion Analysis of strawberry headspace An example emission profile of a whole strawberry is shown in Figure 2. This chromatogram has been processed by TargetView to remove unwanted background signals, and therefore improve both the identification of trace-level components and the quality of the mass spectra. Following this, the 1 most abundant peaks were searched against a commercial library (NIST 11) using a TargetView all-component search. A lower limit of 7 was placed on the match factor in order to ensure that only high-quality matches were reported. The outcome of this was a list of 76 major compounds identified in the sample, including key olfactory components such as esters and terpenoids (see Table A1 in the Appendix).

3 Page Ethanol 3 Acetone 4 Methyl acetate 5 Acetic acid 9 Butan-1-ol 15 Methyl butanoate 19 Ethyl butanoate 22 1-Methylethyl butanoate 35 Methyl hexanoate 39 Butyl butanoate 4 Ethyl hexanoate 41 Hex-3-en-1-ol acetate 42 Hexyl acetate 43 Hex-2-en-1-ol acetate 5 3,7-Dimethylocta-1,6-dien-3-ol 59 Octyl acetate 62 Octyl butanoate 66 Decalactone 71 Nerolidol 76 1,2,3,6,7,8,9,1,11,12- Decahydrobenzo[e]pyrene Time (min) Figure 2: Analysis of the headspace profile of a whole strawberry, sampled onto a sorbent tube using the Micro-Chamber/Thermal Extractor, and analysed by GC and BenchTOF. The 2 most abundant compounds are labelled (the numbers correlate to those in Table A1 in the Appendix). Detection of sulfur compounds Low-level sulfur compounds in the aroma profile of strawberries and other foods are known or suspected to be strongly linked to customer perception of the quality and flavour of the foodstuff 1. However, previous studies into their sensory role have been hampered by difficulties in detecting and identifying these compounds at very low levels, particularly in complex data sets, where they can be hidden under baseline features or more abundant components. To see if any sulfur compounds were present in these samples, a search of the chromatogram in Figure 2 was conducted using a target library containing 26 sulfurcontaining compounds. To ensure only the most confident matches were reported, a stricter match coefficient of.8 was applied (corresponding to a match factor of 8 in the NIST search). The results of this search are shown in Table 1. This search demonstrated the presence of seven sulfur species from the library, including dimethyl disulfide and ethyl (methylthio)acetate, as shown in Figure 3. Cross-checking the spectra of these two trace-level components against those in NIST using TargetView s Search NIST option confirmed their identity, with very good forward match coefficients of 92 and 812 respectively. This also demonstrated the quality of the spectra produced by BenchTOF instruments. Target compound Retention time (min) Match coefficient Peak sum (TIC) Sulfur dioxide Carbon disulfide Methyl thioacetate Dimethyl disulfide Dimethyl sulfone S-Methyl butanethioate Ethyl (methylthio)acetate Table 1: Results obtained using TargetView for a sample processed against a library containing sulfur compounds. Note also the difference in peak sum for methyl thioacetate and dimethyl sulfone, indicating a dynamic range of over three orders of magnitude. Adoption of GC TOF MS technology, with its inherent advantages of sensitivity and speed, was hampered historically by the fact that many early systems produced distorted spectra that could not be used to search standard libraries. The fact that BenchTOF instruments produce reference-quality spectra allows users to take full advantage of commercial libraries such as NIST and Wiley.

4 Page 4 A Retention time (min) B Dimethyl disulfide Ethyl (methylthio)acetate Retention time (min) Retention time (min) C Dimethyl disulfide Forward match Reverse match Probability % Ethyl (methylthio)acetate Forward match Reverse match Probability % S S S O O Figure 3: (A, B) Detection of the deconvolved peaks for dimethyl disulfide and ethyl (methylthio)acetate (red traces) alongside co-eluting peaks (grey traces). (C) The corresponding mass spectra (top, red) compared to those in the NIST library (bottom, blue). Optimising system sensitivity It is well-established that dynamic headspace enrichment followed by TD pre-concentration offers considerable sensitivity advantages for the analysis of VOC profiles from bulk samples 2. With this confirmed for the case of strawberry headspace, attention turned to the issue of detector sensitivity. Quadrupole mass spectrometers offer a robust MS option for GC detection, and are widely used in many routine and research laboratory environments. However, they collect full spectral data by repeatedly scanning across the mass range, thus limiting system sensitivity. Detection limits can be greatly enhanced by moving to SIM mode, but the lack of spectra then compromises qualitative analysis, particularly of unknowns. In-depth analysis of trace compounds in complex samples may therefore be impossible (or at least require multiple runs) in order to obtain sufficient information about the analytes of interest. TOF MS technology monitors all ions without scanning, and thus generates full spectral information at lower mass/concentration levels. This is particularly true for BenchTOF instruments, which employ direct ion extraction in the source, rather than the less efficient orthogonal extraction used in most conventional TOF instruments for GC. Parallel analyses of the strawberry headspace samples were run using a TD GC quadrupole MS system and a TD GC BenchTOF system to compare the differences. Figure 4 shows the two chromatograms at the same scale, illustrating the sensitivity difference between the two systems, while Figure 5 shows the quadrupole results scaled by a factor

5 Page 5 of 1 for ease of comparison. Although different strawberries were used for the two analyses, the VOC profiles show a high degree of similarity. Clearly, these results demonstrate the sensitivity enhancement that can be achieved using a BenchTOF instrument rather than a single-quadrupole MS for the collection of full spectral information. This makes BenchTOF instruments suitable for the identification of trace compounds, both targets and unknowns, even in the complex chromatographic data generated by foodstuffs such as strawberries. The collection of full spectral information at these low detection levels would also enable users to re-examine stored data for new target species (such as allergens, toxins and olfactory components) should the need arise Quadrupole TOF Time (min) Figure 4: Comparison of the TIC chromatograms obtained using quadrupole and TOF MS detection for the TD GC analysis of large volumes of headspace from whole strawberries collected on sorbent tubes. Analytical conditions were the same in both cases, and the two data sets are displayed on the same scale Quadrupole ( 1) TOF Time (min) Figure 5: TD GC MS (quadrupole and TOF) data for dynamic strawberry headspace samples as shown in Figure 4, but with the quadrupole data scaled by a factor of 1.

6 Page 6 Conclusions In this Application Note, we have shown the ease with which flavour compounds can be profiled and trace-level components can be detected when dynamic headspace extraction and thermal desorption pre-concentration are combined with the inherent sensitivity of BenchTOF instruments. Moreover, we have demonstrated that the 1, spectra per second acquired by BenchTOF, and the reference-quality spectra produced, provide TargetView with the data needed to reliably deconvolve target peaks from baseline interferences and other compounds, and thus enable confident identification. The whole system, therefore, provides high sensitivity (and wide dynamic range) at the same time as allowing both target and unknown compounds to be detected in this complex matrix a task that would otherwise be time-consuming and require considerable skill and experience on the part of the analyst. It is also worth pointing out that the superior sensitivity delivered by BenchTOF instruments would also allow the gas flow from the GC to be split without compromising compound identification. This capability is valuable in food aroma analysis, because it allows the sample to be re-collected for repeat analysis using different GC parameters (e.g. for quantitative analysis of the major constituents), or analysed in parallel using a different technique such as olfactometry, for identification of aroma contributions from individual chemicals. References 1. X. Du, V. Whitaker and R. Rouseff, Changes in strawberry volatile sulfur compounds due to genotype, fruit maturity and sample preparation, Flavour and Fragrance Journal, 212, 27: ; X. Du, M. Song and R. Rouseff, Identification of new strawberry sulfur volatiles and changes during maturation, Journal of Agricultural and Food Chemistry, 211, 59: For examples, see Application Notes 88 (fruit juices and wine), 96 (tobacco) and 11 (cheese). Trademarks BenchTOF, Micro-Chamber/Thermal Extractor, SulfiCarb, TargetView and TD-1 are trademarks of Markes International. Tenax is a registered trademark of Buchem B.V., The Netherlands. Applications were performed under the stated analytical conditions. Operation under different conditions, or with incompatible sample matrices, may impact the performance shown.

7 Page 7 Appendix No. Compound name Retention time (min) Match factor Peak sum (TIC) 1 Isobutene Ethanol Acetone Methyl acetate Acetic acid Hexane Ethyl acetate Methyl propanoate Butan-1-ol Benzene Pentan-2-one Methyl thioacetate Ethyl propanoate n-propyl acetate Methyl butanoate Methylbutan-1-ol Dimethyl disulfide Benzyl methyl ketone Ethyl butanoate Methyl pentanoate Methyl 2-hydroxybutanoate Isopropyl butanoate Ethyl 2-methylbutanoic acid 24 Ethyl 3-methylbutanoate Hex-3-en-1-ol Hex-2-en-1-ol Hexan-1-ol Methylbutyl acetate Methylbutyl acetate Methylhexan-2-one Propyl butanoate Ethyl pentanoate Styrene Pentyl acetate Methyl hexanoate Methylpropyl butanoate Benzaldehyde Phenol Butyl butanoate No. Compound name Retention time (min) Match factor Peak sum (TIC) 4 Ethyl hexanoate Hex-3-enyl acetate Hexyl acetate Hex-2-enyl acetate Ethylhexan-1-ol Isopropyl hexanoate Methylbutyl butanoate Furaneol Dihydromyrcenol Acetophenone Linalool Nonanal Methyl octanoate Ethylhexyl acetate Benzyl acetate Hex-3-enyl butanoate Butyl hexanoate Ethyl octanoate Dodecane Octyl acetate Tridecane Nonyl acetate Octyl butanoate Tetradecane Biphenyl β-farnesene Decalactone α-farnesene β-bisabolene Butylated hydroxy toluene α-muurolene Nerolidol Octyl hexanoate Hexadecane Dodecalactone Isobutyl 2,2,4-trimethyl-3- carboxyisopropylpentanoate 1,2,3,6,7,8,9,1,11,12- Decahydrobenzo[e]pyrene Table A1: Major component list of whole strawberry emission profile. a Concentrations determined in terms of toluene equivalents by comparison with the peak area of a toluene standard analysed under the same conditions. AN515_3_18714

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software NEMC, Washington D.C. August 6 th 2012 Nicola Watson Environmental Specialist Markes International

More information

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation Application Released: January 214 Application Note 522 Characterisation of allergens in cosmetics by GC GC TF MS with Select-eV variable-energy electron ionisation Summary This Application Note shows that

More information

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT AppNote 4/2008 Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps John R. Stuff, Jacqueline A. Whitecavage Gerstel, Inc., 701 Digital Drive, Suite J, Linthicum, MD

More information

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ Application Note Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ -3 Application Note Abstract This application note demonstrates the

More information

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist Innovative Thermal Desorption From Agilent Technologies Vivek Dhyani Application Chemist What is thermal desorption (TD)? How does thermal desorption compare to Head Space? Thermal desorption (TD) is the

More information

Application Note 032

Application Note 032 Application Note 3 Analysis of Sulfur Compounds Using On-line and Off line TD GC Application Note Abstract This application note shows how Markes TD technology is compatible with trace level sulfur compounds,

More information

Application Note 059 Direct Desorption of Car Trim Materials for VOC and SVOC Analysis in Accordance with VDA Method 278

Application Note 059 Direct Desorption of Car Trim Materials for VOC and SVOC Analysis in Accordance with VDA Method 278 Application Note Direct Desorption of Car Trim Materials for VOC and SVOC Analysis in Accordance with VDA Method Application Note Abstract In this application note, we demonstrate the suitability of Markes

More information

Series 2. Continuous monitoring of trace chemical vapours

Series 2. Continuous monitoring of trace chemical vapours Series 2 TT24-7 Continuous monitoring of trace chemical vapours Series 2 TT24-7 TT24-7 Series 2 Continuous monitoring of trace chemical vapours The TT24-7 Series 2 is an advanced thermal desorption (TD)

More information

Thermal Desorption Technical Support

Thermal Desorption Technical Support Thermal Desorption Technical Support Note 47: The Analysis of Landfill Gas Compounds using Thermal Desorption GC/MS and a Retention Time Locked Database Key Words: VOCs, directive, compliance, identifi

More information

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation JSB is an authorised partner of Application Note 522 Application Released: January 214 Characterisation of allergens in cosmetics by GC GC TF MS with Select-eV variable-energy electron ionisation Summary

More information

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS International Gas Union Research Conference 14 THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS Main author Hironori IMANISHI Tokyo Gas Co., Ltd. JAPAN himanishi@tokyo-.co.jp

More information

Thermal Desorption Technical Support

Thermal Desorption Technical Support Thermal Desorption Technical Support Note 86a: US EPA Method TO-17 for Monitoring Air Toxics in Ambient Air Using Sorbent Tubes and Automated, Cryogen-free Thermal Desorption Application Note Environmental,

More information

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles LECO Corporation; Saint Joseph, Michigan USA Key Words: GC-TOFMS, GC-MS, Pegasus BT, HS-SPME,

More information

Centri. A breakthrough in sample automation and concentration for GC MS

Centri. A breakthrough in sample automation and concentration for GC MS Centri A breakthrough in sample automation and concentration for GC MS Centri Fully automated multi-mode sampling and concentration system for GC MS. Built using best-in-class robotic automation and harnessing

More information

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation Introduction Fire investigation involves many different types of analyses from crime scene

More information

Determination of Hydrocarbon Components in Petroleum Naphthas

Determination of Hydrocarbon Components in Petroleum Naphthas Determination of Hydrocarbon Components in Petroleum Naphthas LECO Corporation; Saint Joseph, Michigan USA Key Words: GC-TOFMS, Petrochemical, Naphtha, Deconvolution, Retention Index 1. Introduction The

More information

Headspace Technology for GC and GC/MS: Features, benefits & applications

Headspace Technology for GC and GC/MS: Features, benefits & applications Headspace Technology for GC and GC/MS: Features, benefits & applications Karima Baudin Oct 2015 Why use Headspace? Very Simple no to minimum sample prep Robust enhance uptime Non-detectable carry-over

More information

Analysis of Fast Moving Consumer Goods (FMCG) using GCMS with static and dynamic headspace (HS)

Analysis of Fast Moving Consumer Goods (FMCG) using GCMS with static and dynamic headspace (HS) PO-CON1789E Analysis of Fast Moving Consumer Goods (FMCG) using GCMS with static and dynamic headspace (HS) ASMS 2017 TP 280 Dheeraj Handique, Ankush Bhone, Durvesh Sawant, Prashant Hase, Sanket Chiplunkar,

More information

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek Automated Handling Techniques for the Analysis of Elevated Volatile Organic Compound (VOC) Concentrations in Soils Utilizing the Atomx Concentrator/Multimatrix Autosampler. Application Note By: Anne Jurek

More information

HiSorb sorptive extraction

HiSorb sorptive extraction HiSorb sorptive extraction Rapid, versatile analysis of VCs & SVCs in liquids and solids by TD GC MS Distribuido en España por: Tel: (+3) 9.5.77 Fax: (+3) 9..77 www.ingenieria-analitica.com, inf@ingenieria-analitica.com

More information

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A Application Note 19060203 Keywords Coffee Essential Oil Flavor Fragrance Gas Chromatograph (GC) Sulfur Compounds Abstract Sulfur compounds

More information

Analysis of complex petrochemicals by GC GC TOF MS with Select-eV variable-energy electron ionisation

Analysis of complex petrochemicals by GC GC TOF MS with Select-eV variable-energy electron ionisation JS is an authorised partner of pplication Note 54 nalysis of complex petrochemicals by GC GC TOF MS with Select-eV variable-energy electron ionisation Summary This pplication Note shows that enchtof instruments,

More information

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 77A mini TD and 70A GC Application Note Environmental Authors Tingting Bu, Xiaohua Li Agilent Technologies (Shanghai) Co.,

More information

Low-Level Sulfur Compounds in Beer by Purge and Trap with a Pulsed Flame Photometric Detector (PFPD)

Low-Level Sulfur Compounds in Beer by Purge and Trap with a Pulsed Flame Photometric Detector (PFPD) Application Note 16181100 Low-Level Sulfur Compounds in Beer by Purge and Trap with a Pulsed Flame Photometric Detector (PFPD) Keywords Beer PFPD Purge and Trap Sulfur Introduction The presence or absence

More information

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results P EGAU 4D GCxGC TFM Delivering the Right Results LEC s P EGAU 4D GCxGC-TFM The Ultimate Analytical Instrument Pioneering GCxGC technology, combined with the Pegasus TFM and ChromaTF software provides today

More information

Sampling and Analysis Methodology Concerns for Volatile Organo-Sulfur Compounds (VOSCs)

Sampling and Analysis Methodology Concerns for Volatile Organo-Sulfur Compounds (VOSCs) Sampling and Analysis Methodology Concerns for Volatile Organo-Sulfur Compounds (VOSCs) Paper 614 Eric C. Sivret, Gavin Parcsi, and Richard M. Stuetz UNSW Water Research Centre, The University of New South

More information

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS Application Note Environmental Author Xiaohua Li Agilent Technologies (Shanghai)

More information

Identifying Disinfection Byproducts in Treated Water

Identifying Disinfection Byproducts in Treated Water Identifying Disinfection Byproducts in Treated Water Jonathan D. Byer, LEC Corporation; Saint Joseph, Michigan USA Susan D. Richardson, University of South Carolina; Columbia, South Carolina USA 1. Introduction

More information

TIME OF FLIGHT GC/MSTOF

TIME OF FLIGHT GC/MSTOF A New Concept of TOF-MS for the Latest Generation GC Techniques When productivity is the name of the game, MASTER TOF-MS is the answer Productivity has become of vital importance in most modern laboratories.

More information

Volatile Organic Compounds in Every Day Food

Volatile Organic Compounds in Every Day Food Volatile Organic Compounds in Every Day Food Application Note Abstract Volatile Organic Compounds (VOCs) have been analyzed in drinking water and pharmaceuticals extensively in recent years. Now, VOCs

More information

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS Application Note #1820230 Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS GC-MS Introduction USEPA Method 8270 [1] for semivolatiles is is used by by laboratories to measure

More information

Application of multi-dimensional GC techniques to the analysis of cigarette smoke

Application of multi-dimensional GC techniques to the analysis of cigarette smoke Application of multi-dimensional GC techniques to the analysis of cigarette smoke M. Brokl, J. Foçant, University of Liège, Belgium L. Bishop, J.Ticha, C. Wright, British American Tobacco Group Research

More information

VOC TEST REPORT M1. 6 April Regulation or protocol Conclusion Version of regulation or protocol

VOC TEST REPORT M1. 6 April Regulation or protocol Conclusion Version of regulation or protocol Dana Lim A/S Københavnsvej 220 4600 Køge DENMARK Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark VOC@eurofins.com www.eurofins.com/voc-testing VOC TEST REPORT M1 6 April 2017 1 Sample

More information

Application Note. Application Note 081 Innovative Cryogen-Free Ambient Air Monitoring in Compliance with US EPA Method TO-15. Abstract.

Application Note. Application Note 081 Innovative Cryogen-Free Ambient Air Monitoring in Compliance with US EPA Method TO-15. Abstract. Application Note 8 Innovative Cryogen-Free Ambient Air Monitoring in Compliance with US EPA Method TO-5 Application Note Environmental, Canister, TO-5, Air Monitoring, Air Toxics Abstract This application

More information

Test Report. Muovihaka Oy. Product Emissions in accordance with the Swedish Building Material Assessment Ultima graphite.

Test Report. Muovihaka Oy. Product Emissions in accordance with the Swedish Building Material Assessment Ultima graphite. Test Report Muovihaka Oy Product Emissions in accordance with the Swedish Building Material Assessment July 2012 Client: Muovihaka Oy Kuusimäentie 12 01900 Nurmijärvi Finland Date: 26 July 2012 Testing

More information

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions GAS CHROMATOGRAPHY MASS SPECTROMETRY Pre-Lab Questions Questions to be answered before doing the experiment. The answers are due at the beginning of each experiment without exception (the questions are

More information

M1 Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04

M1 Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04 Würth International AG Aspermontstrasse 1 CH-7000 Chur Switzerland M1 Test Report Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark voc@eurofins.com www.eurofins.com/voc-testing Date 28

More information

Thermal Desorption Technical Support. Note 56: TD-GC/MS analysis of vapour-phase organic compounds for materials emissions testing.

Thermal Desorption Technical Support. Note 56: TD-GC/MS analysis of vapour-phase organic compounds for materials emissions testing. Thermal Desorption Technical Support Note 56: TD-GC/MS analysis of vapour-phase organic compounds for materials emissions testing Keywords certification protocols, (T)(V)(S)VOCs, ULTRA-UNITY, field/laboratory

More information

Test Report ROMA USA LLC. Product Emissions of Furniture in accordance with. Cradle to Cradle section 5.8 ECODOMUS SATIN BASE TR.

Test Report ROMA USA LLC. Product Emissions of Furniture in accordance with. Cradle to Cradle section 5.8 ECODOMUS SATIN BASE TR. Test Report ROMA USA LLC Product Emissions of Furniture in accordance with Cradle to Cradle section 5.8 ECODOMUS SATIN BASE TR March 2015 Client: ROMA USA LLC 554 North Avenue NW, Suite B Atlanta, GA 30318

More information

U.S. EPA Method 8270 for multicomponent analyte determination

U.S. EPA Method 8270 for multicomponent analyte determination ENVIRONMENTAL application note U.S. EPA Method 8270 for multicomponent analyte determination Elaine A. LeMoine and Herman Hoberecht Introduction Multicomponent analytes are compounds that yield several

More information

VOC TEST REPORT EMICODE

VOC TEST REPORT EMICODE Bostik SA 253 rue du Président Wilson 93211 La Plaine St Denis Cedex FRANCE Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark VOC@eurofins.com www.eurofins.com/voc-testing VOC TEST REPORT

More information

CIA Advantage-xr. Cryogen-free automated canister and whole-air sampling system

CIA Advantage-xr. Cryogen-free automated canister and whole-air sampling system CIA Advantage-xr Cryogen-free automated canister and whole-air sampling system CIA Advantage-xr Introducing the CIA Advantage-xr a cryogen-free system for the automated GC and GC MS analysis of trace-level

More information

Test Report. Glava AS. Emission test of Ecophon Venus according to M1 classification. October / November Smedeskovvej 38, DK-8464 Galten

Test Report. Glava AS. Emission test of Ecophon Venus according to M1 classification. October / November Smedeskovvej 38, DK-8464 Galten Test Report Glava AS Emission test of Ecophon Venus according to M1 classification October / November 2006 Client: Glava AS Nybråtveien 2 1832 Askim Norge Date: 8 th of November 2006 Testing Laboratory:

More information

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK Multi-residue GC-MS analysis Richard Fussell CSL York, UK e-mail: r.fussell@csl.gov.uk Outline of Presentation Background Gas Chromatography Mass Spectrometry - Options Capabilities and Applications Summary

More information

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System Application Note Abstract The Massachusetts Department of Environmental Protection (MassDEP) developed the Method

More information

TDTS 16 Round-the-clock, on-line and cryogen-free monitoring of hydrocarbons from acetylene to trimethylbenzene in ambient air

TDTS 16 Round-the-clock, on-line and cryogen-free monitoring of hydrocarbons from acetylene to trimethylbenzene in ambient air Application TDTS 16 Round-the-clock, on-line and cryogen-free monitoring of hydrocarbons from acetylene to trimethylbenzene in ambient air Summary This Application Note describes validation of a thermal

More information

Electronic Supplementary Information (ESI)

Electronic Supplementary Information (ESI) Electronic Supplementary Material (ESI) for Analytical Methods. This journal is The Royal Society of Chemistry 2016 Electronic Supplementary Information (ESI) Application of dynamic headspace and gas chromatography

More information

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer Application Note By: Anne Jurek Abstract This application note presents

More information

EMICODE Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04

EMICODE Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04 Sika Technology AG Tüffenwies 16 8048 Zürich SWITZERLAND EMICODE Test Report 1 Sample Information Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark voc@eurofins.com www.eurofins.com/voc-testing

More information

Breath Analysis Investigating the Human Volatome by ATD-GCMS

Breath Analysis Investigating the Human Volatome by ATD-GCMS Breath Analysis Investigating the Human Volatome by ATD-GCMS Presented by - Renee Cataneo Mayur Mundada Contributors Michael Phillips MD(Menssana Research Inc. CEO) Mark Libardoni PhD (Southwest Research

More information

VOC TEST REPORT M1. 16 August Regulation or protocol Conclusion Version of regulation or protocol

VOC TEST REPORT M1. 16 August Regulation or protocol Conclusion Version of regulation or protocol SGS-Doors A/S Thrigesvej 8-16 7430 Ikast DENMARK Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark VOC@eurofins.com www.eurofins.com/voc-testing VOC TEST REPORT M1 16 August 2016 1 Sample

More information

Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS

Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS Application Note By Tyler Trent Abstract In order to determine the concentration of volatile organic compounds

More information

Introduction to GC/MS

Introduction to GC/MS Why Mass Spectrometry? Introduction to GC/MS A powerful analytical technique used to: 1.Identify unknown compounds 2. Quantify known materials down to trace levels 3. Elucidate the structure of molecules

More information

AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION

AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION Paper # 164-8P Pittsburgh Conference 24 T. Wampler, C. Zawodny, L. Mancini CDS Analytical, Inc 465 Limestone Road, Oxford,

More information

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260 Using Hydrogen as An Alternative Carrier Gas for US EPA 8260 Application Note Abstract Due to regional shortages and increasing costs of helium, the preferred carrier gas in gas chromatography, alternative

More information

Determination of Volatile Substances Proof of Food Adulteration

Determination of Volatile Substances Proof of Food Adulteration ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE Determination of Volatile Substances Proof of Food Adulteration (method: gas chromatography with mass spectrometric detection) Exercise guarantor:

More information

VOC TEST REPORT M1. 23 October Regulation or protocol Conclusion Version of regulation or protocol

VOC TEST REPORT M1. 23 October Regulation or protocol Conclusion Version of regulation or protocol Würth Oy Würthintie 1 11710 Riihimäki Finland Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark VOC@eurofins.com www.eurofins.com/voc-testing VOC TEST REPORT M1 23 October 2017 1 Sample

More information

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench Application Note Forensic Toxicology and Drug Testing Author Jared Bushey Agilent Technologies, Inc. 285 Centerville

More information

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer Purchasing a mass spectrometer (MS) is an important investment for a laboratory. When considering instrument platforms, selection

More information

Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C

Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C APPLICATION NOTE 10441 Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C Authors Andrea Caruso, 1 Tommaso Albertini, 1 Jacob A. Rebholz 2 ; 1 Thermo Fisher Scientific,

More information

Test Report. Tremco-Illbruck GmbH & Co KG. Product Emissions Test (AgBB/DIBt Test Protocol) Butyl und Bitumenprimer. June 2011

Test Report. Tremco-Illbruck GmbH & Co KG. Product Emissions Test (AgBB/DIBt Test Protocol) Butyl und Bitumenprimer. June 2011 Test Report Tremco-Illbruck GmbH & Co KG Product Emissions Test (AgBB/DIBt Test Protocol) Butyl und Bitumenprimer June 2011 Client: Tremco-Illbruck GmbH & Co KG Von Der Wettern Str. 27 51149 Köln Germany

More information

high performance OPTIC 3 and applications a total analytical solution

high performance OPTIC 3 and applications a total analytical solution high performance OPTIC 3 and applications a total analytical solution Excellent by nature Excellent effectivity, efficient performance and great flexibility. OPTIC 3: a fully programmable injector for

More information

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making Restek GC DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making Officially listed USP SA and SNS support material. Ideal for USP and ASTM methods that use white diatomaceous

More information

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative. We don t have anything against mass spectrometry. We just think it s time for a worthy alternative. gas chromatography detector New directions in science are launched by new tools much more often than

More information

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW Paula Hong, John Van Antwerp, and Patricia McConville Waters Corporation, Milford, MA, USA Historically UV detection has been

More information

VOC TEST REPORT AgBB

VOC TEST REPORT AgBB Bostik SA 253 rue du Président Wilson 93211 La Plaine St Denis Cedex FRANCE Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark VOC@eurofins.com www.eurofins.com/voc-testing VOC TEST REPORT

More information

UNIQUE SOLUTION FOR FLAVOUR AND FRAGRANCE IDENTIFICATION BY MEANS OF GC-MS (TOF) / CONDENSED PHASE FTIR

UNIQUE SOLUTION FOR FLAVOUR AND FRAGRANCE IDENTIFICATION BY MEANS OF GC-MS (TOF) / CONDENSED PHASE FTIR UNIQUE SOLUTION FOR FLAVOUR AND FRAGRANCE IDENTIFICATION BY MEANS OF GC-MS (TOF) / CONDENSED PHASE FTIR APPLICATION NOTE Authors: Margita Utczàs * William W. Carson ** Luigi Mondello * *Chromaleont *DANI

More information

VOC TEST REPORT EMICODE

VOC TEST REPORT EMICODE Polyseam Ltd Shaw Park, Silver Street Huddersfield, West Yorkshire, HD5 9AF UK Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark VOC@eurofins.com www.eurofins.com/voc-testing VOC TEST REPORT

More information

Permanent Gas Analysis by Gas Chromatography Vacuum Ultraviolet Spectroscopy

Permanent Gas Analysis by Gas Chromatography Vacuum Ultraviolet Spectroscopy Application Note Permanent Gas Analysis by Gas Chromatography Vacuum Ultraviolet Spectroscopy Permanent Gas Analysis by Gas Chromatography Vacuum Ultraviolet Spectroscopy Introduction Gas Chromatography

More information

ICP-MS. High Resolution ICP-MS.

ICP-MS. High Resolution ICP-MS. ICP-MS attom ES High Resolution ICP-MS www.nu-ins.com Attom ES Enhanced Sensitivity Enhanced Speed Enhanced Selectivity Enhanced Software The Attom ES from Nu Instruments is a double focussing inductively

More information

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0. System Description The VUV PIONA + Analyzer is a VGA-100 Gas Chromatography (GC) detector configured for PIONA compound analysis by the VUV PIONA + method. The VUV PIONA + method uses relatively simple

More information

Methanol Extraction of high level soil samples by USEPA Method 8260C

Methanol Extraction of high level soil samples by USEPA Method 8260C Methanol Extraction of high level soil samples by USEPA Method 8260C Abstract In order to determine the concentration of Volatile Organic Compounds (VOCs) in soil and waste samples the USEPA developed

More information

TDTS. Keywords. Introduction. TD Operation; Calibration; Impedance; Discrimination

TDTS.   Keywords. Introduction. TD Operation; Calibration; Impedance; Discrimination Thermal Desorption Technical Support Note 75: Liquid standard injection, tube impedance and other factors which may cause discrimination during the calibration of thermal desorption methods Keywords TD

More information

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application Static Headspace Blood Alcohol Analysis with the G Network Headspace Sampler Application Forensics Author Roger L. Firor and Chin-Kai Meng Agilent Technologies, Inc. 0 Centerville Road Wilmington, DE 90-0

More information

Analysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic

Analysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic Analysis of pesticide residues using various GC/MS systems Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic OUTLINE Czech Agriculture and Food Inspection Authority (CAFIA)

More information

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA 94804-3614 Ph. 510-236-2325; Fax 510-236-2335 E-mail info@berkeleyanalytical.com VOC Emissions from Building Products Customer & Building

More information

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative. We don t have anything against mass spectrometry. We just think it s time for a worthy alternative. gas chromatography detector Everything you need in one GC detector Universal and selective detector with

More information

Introduction. Chapter 1. Learning Objectives

Introduction. Chapter 1. Learning Objectives Chapter 1 Introduction Learning Objectives To understand the need to interface liquid chromatography and mass spectrometry. To understand the requirements of an interface between liquid chromatography

More information

Detection of Chemical Warfare Agents by Transportable GC/MS

Detection of Chemical Warfare Agents by Transportable GC/MS Detection of Chemical Warfare Agents by Transportable GC/MS Application Note Gas Chromatography/Mass Spectrometry Author Robert V. Mustacich Agilent Technologies, Inc. 5301 Stevens Creek Boulevard Santa

More information

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography Introduction ASTM International publishes a number of different methods for the determination of volatile compounds in water-based coatings.

More information

Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler

Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler Application Note By: Anne Jurek Abstract In order to determine the amount

More information

EMICODE Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No. G12871B_02

EMICODE Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No. G12871B_02 Polyseam A/S Ravneveien 7 Linnestad Næringsområde 3174 Revetal Norway Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark voc@eurofins.com www.eurofins.com/voc-testing Date 09 October 2014

More information

Basic Organic Chemistry Nomenclature CHEM 104 B

Basic Organic Chemistry Nomenclature CHEM 104 B Basic Organic Chemistry Nomenclature CHEM 104 B I have gone ahead and compiled all of the basic naming rules that we will be dealing with into one worksheet. I hope this will be helpful to you as you work

More information

Automated Characterization of Compounds in Fire Debris Samples

Automated Characterization of Compounds in Fire Debris Samples 125 Sandy Drive, Newark, Delaware 19713 USA tel: 302-737-4297 fax: 302-737-7781 www.midi-inc.com Automated Characterization of Compounds in Fire Debris Samples Application Note Forensics Fire Debris Analysis

More information

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application Food Safety, Environmental Authors Chin-Kai Meng and Bruce Quimby Agilent Technologies, Inc. 2850 Centerville

More information

Seattle Central Community College Science and Math Division. Chemistry 211 Analysis of Flavor Component of Gum and Candy by GCMS

Seattle Central Community College Science and Math Division. Chemistry 211 Analysis of Flavor Component of Gum and Candy by GCMS Seattle Central Community College Science and Math Division Chemistry 211 Analysis of Flavor Component of Gum and Candy by GCMS Introduction Fruity, juicy, aromatic or creamy the joys of flavor are sensuous.

More information

Understanding Gas Chromatography

Understanding Gas Chromatography Understanding Gas Chromatography What is Really Going on Inside the Box? Simon Jones GC Applications Engineer Page 1 Group/Presentation Title Month ##, 200X ?? K? Page 2 Typical GC System Gas supply Injector

More information

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW NEXT GENERATION MASS SPECTROMETRY CONTENTS: 3 How SIFT-MS works 4 Soft chemical ionisation 5 Quantification in real-time 6 Utilising

More information

SIFT-MS. technology overview

SIFT-MS. technology overview SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY technology overview contents 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why three reagent ions? c. How does SIFT-MS

More information

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION. APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Author: Kira. Yang PerkinElmer, Inc. Shanghai, China Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS Introduction

More information

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography. Chemical Analysis Low Level Oxygenates Analyzer Trace Analysis of Oxygenates in Hydrocarbon Matrices think forward Gas Chromatography The determination of sub to high ppm levels of ethers, alcohols, aldehydes

More information

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS Application Note Food Authors Nobuo Ochiai and Kikuo Sasamoto GERSTEL K.K. 2-13-18 Nakane

More information

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek Requirements of an Automated Sample Delivery System in Today s Realm of Ever Increasing Sensitivity Demands Utilizing the Atomx Concentrator/Multimatrix Autosampler. Application Note By: Anne Jurek Abstract

More information

Cerno Application Note Extending the Limits of Mass Spectrometry

Cerno Application Note Extending the Limits of Mass Spectrometry Confident Compound Identification with High Mass Accuracy and Elemental Composition Specific NIST Library Search Identification of unknown compounds by unit mass resolution GC-MS systems essentially relies

More information

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA 94804-3614 Ph. 510-236-2325; Fax 510-236-2335 E-mail info@berkeleyanalytical.com VOC Emissions from Building Products Customer & Building

More information

Aroma characterization based on aromatic series analysis in table. grapes

Aroma characterization based on aromatic series analysis in table. grapes Aroma characterization based on aromatic series analysis in table grapes Yusen Wu, Shuyan Duan, Liping Zhao, Zhen Gao, Meng Luo, Shiren Song, Wenping Xu, Caixi Zhang, Chao Ma*, Shiping Wang* Department

More information

Multi-residue analysis of pesticides by GC-HRMS

Multi-residue analysis of pesticides by GC-HRMS An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict

More information

VOC TEST REPORT CDPH

VOC TEST REPORT CDPH Euro Trade Flooring SL. Pol. Ind. Can Estella c/galileo no. 11 08635 Sant Esteve Sesrovires BARCELONA SPAIN Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark VOC@eurofins.com www.eurofins.com/voc-testing

More information

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS Application Note US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS Author Amy Nutter Applications Chemist, Teledyne Tekmar Abstract US EPA Method 8260 in conjunction

More information

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Replaces: Dated: Author: Date: AM-No.: New New Nils Arne Jentoft 18.06.2014 0 CHANGES This procedure is new. 1 SCOPE This document describes

More information