Copyright 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

Size: px
Start display at page:

Download "Copyright 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim"

Transcription

1 Gauchotte-Lindsay, C., McGregor, L. A., Assal, A., Thomas, R., and Kalin, R. M. (2014) Highlighting the effects of co eluting interferences on compound specific stable isotope analysis of polycyclic aromatic hydrocarbons using comprehensive two dimensional gas chromatography. ChemPlusChem, 79 (6). pp ISSN Copyright 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim A copy can be downloaded for personal non-commercial research or study, without prior permission or charge Content must not be changed in any way or reproduced in any format or medium without the formal permission of the copyright holder(s) When referring to this work, full bibliographic details must be given Deposited on: 01 October 2014 Enlighten Research publications by members of the University of Glasgow

2 Highlighting the effects of co eluting interferences on compound specific stable isotope analysis of polycyclic aromatic hydrocarbons using comprehensive two dimensional gas chromatography Caroline Gauchotte Lindsay [a,b]*, Laura A. McGregor [a], Antoine Assal [a], Russell Thomas [c ]and Robert M. Kalin [a] [a] [b] [c] Dr C Gauchotte Lindsay, Dr L McGregor, Dr A Assal, Prof R Kalin Department of Civil and Environmental Engineering University of Strathclyde, UK. John Anderson Building, 107 Rottenrow, Glasgow, UK. Dr C Gauchotte Lindsay * (corresponding author) now at Infrastructure and Environment Research Division School of Engineering University of Glasgow, UK. Rankine Building, Oakfield Avenue, Glasgow, UK. E mail: caroline.gauchotte lindsay@glasgow.ac.uk Dr R Thomas Parsons Brinckerhoff Queen Victoria House, Redland Hill, Bristol, UK. Accuracy is the most important issue when carrying out compound specific stable isotope analysis of polycyclic aromatic hydrocarbons extracted from complex samples. It depends on two main factors: the possible isotopic fractionation of the compounds during extraction and the potential co elution with interfering compounds with different isotopic signatures. We present here a simplified pressurised liquid extraction method for compound specific stable isotope analysis of polycyclic aromatic hydrocarbons (PAHs) in non aqueous phase liquids of coal tar. Samples extracted using the new method and using fractionation on silica gel column were analysed using comprehensive twodimensional gas chromatography. We were able to evaluate the effect of coelution on carbon and hydrogen stable isotope signatures of the 16 US EPA priority PAHs in the coal tars with various proportions of aromatic and aliphatic content. Even in samples that presented a good baseline resolution, the PAHs of interest co eluted with other aromatic compounds with a notable effect on their stable isotope values; it demonstrated the necessity to check the quality of all extraction and clean up methods (either the simplified pressurized liquid extraction or more traditional labour intensive methods) for the more complex samples prior to data interpretation. Additionally, comprehensive twodimensional gas chromatography enabled visualisation of the suspected coelutions for the first time. Introduction Polycyclic aromatic hydrocarbons (PAHs) are a ubiquitous global contaminant, produced by a number of sources, including vehicle emissions and fuel combustion1. Many PAHs are known to have toxic, mutagenic and carcinogenic properties2, making their source, fate and remediation within the environment a

3 highly studied topic. However, due to the great number (and similarity) of potential PAH sources it is often difficult to provide irrefutable source attribution. This is evident in the analysis of coal tars, a by product produced by manufactured gas plants (MGPs), often found in high volumes at contaminated former MGP sites across Europe and North America3. Isotope studies have gained much popularity within environmental forensic investigations, due to their ability to differentiate between chemically identical contaminants4. Compound specific isotope analysis (CSIA) has the additional ability to measure the isotope ratios of individual compounds within a mixture by the coupling of a gas chromatograph to an online combustion or pyrolysis unit and an isotope ratio mass spectrometer5. Nevertheless, this technique still presents a number of challenges, including the requirement for chromatographic baseline separation to ensure co eluting components do not interfere with the accuracy of the isotope ratios5. Unfortunately, most environmental samples, like coal tars, are extremely complex, thus require labour intensive chemical fractionation processes, such as column chromatography, to separate the initial sample extract into chemical classes (e.g. aliphatics and aromatics). The procedure is time consuming and generally requires large solvent volumes. Buczyńska et al.6 recently published an excellent review on the extraction and clean up methods for source identification and apportionment of PAHs using carbon CSIA demonstrating the variety of clean up methods adopted for CSIA of PAHs. Therefore, it would be of great benefit to develop a fast and efficient method of sample fractionation. Accuracy of compound specific stable isotope results will depend on two main factors. Firstly, it is possible that during extraction of the compounds of interest into the solvent phase the ratio of stable isotopes of carbon (13C/12C expressed in δ13c) and hydrogen (D/H expressed in δd) can be changed through isotopic fractionation6 8. Secondly, because in the combustion reactor, compounds are all converted quantitatively into CO2, (and to H2 in the pyrolysis reactor) if two or more compounds are in the reactor at the same time, the resulting stable isotope ratio value is a weighted average of the stable isotope ratio of the coeluting compounds7,8. The two factors are conflicting, as while limiting extraction steps will limit the isotopic fractionation, it will also result in greater chromatographic interference. The lack of reference material for stable isotope analysis of PAHs in complex environmental samples means that the influence of these factors is difficult to evaluate or quantify. In their review, Buczyńska et al.6 summarise the various approached adopted by scientists to deal with these issues. In general, We present a one step extraction method of PAHs from coal tar dense nonaqueous phase liquids (DNAPLs) using pressurised liquid extraction (PLE) with on line clean up. PAHs are the main chemical family in coal tar samples as coal tar is produced from the combustion of coal. The concentrations of PAHs in coal tar are significantly higher compared to other important families such as alkanes and olefins while in crude oil samples the opposite is true. Consequently, the extraction of PAHs from crude oil samples for stable isotope analysis requires extensive chemical fractionation, clean up and concentrations9. We demonstrate here that because of the prevalence of PAHs in coal tar sample, simpler, less stringent extraction methods can be employed for compound specific stable isotope analysis with comparable precision and accuracy to other methods.

4 The repeatability, and isotopic fractionation associated with the methods were investigated. We uniquely used comprehensive two dimensional chromatography coupled with time of flight mass spectrometry (GCxGC TOFMS) to assess co elution of PAHs with interfering compounds in the aromatic fraction and compared it to the aromatic fraction obtained through a silica gel column, providing the first ever visual evidence of co elution. Results and Discussion 1. Chemical fractionation using the one step pressurised liquid extraction. We previously developed a one step pressurised liquid extraction (PLE) for coal tar samples for the analysis of coal tar DNAPL through GCxGC TOFMS using a single hexane fraction We propose here a modified version of this extraction producing two fractions: a hexane fraction (F1) and a (9:1) (v:v) (hexane:toluene) fraction (F2). DNAPL is mixed with equivalent amount of sodium sulphate and diatomaceous earth and silica gel deactivated at 10% is placed below the sample for in cell clean up. The first fraction was aimed at the alkanes and the olefins and the second fraction at the PAHs and other aromatics. When carrying out isotopic measurements, precision, repeatability and more importantly accuracy of the extraction are the crucial factors to be assessed. PLE has been previously shown to provide consistent and reproducible carbon isotope data when used as an extraction method, prior to silica column fractionation, for PAH contaminated soils13. The use of PLE for simultaneous sample extraction and fractionation, however, has not been reported in the literature. Two different coal tars were used to validate the extraction method: coal tar D7 and coal tar D12. These two coal tar DNAPLs are part of a coal tar library that was collected by the authors and more information can be found on both samples and their composition in previous publications Coal tar D7 came from a site where horizontal retorts were used for the gas manufacturing process while coal tar D12 originated from a carburetted water gas (CWG) sites and contained high levels of alkanes due to the use of oil during gas manufacture. After chemical fractionation, PAHs were found in both fractions. A third fraction (F3) was also extracted using 100% toluene. Gas chromatography coupled with mass spectrometry (GC MS) analysis of F3 for the one step PLE showed no measurable volatile or semi volatile compounds, all compounds were extracted through F1 and F2. The difficulty with coal tar samples is the ease of dissolution of the components from the sample matrix. It was found that optimal separation of the aliphatic (F1) and aromatic (F2) classes could be obtained by restricting the duration of time in which the solvent resides in the accelerated solvent extractor cell. This was achieved by setting the static time in the cell to zero, meaning that the solvent flowed directly through the pressurised cell. The oven was also switched off for the initial extraction to limit the elution of PAHs within F1. A portion of the PAHs was still extracted into F1 with the aliphatic compounds; however, F2 presented a good baseline separation for PAHs for both D7 and D12 (see Figure 1 (a) and (b)). 2. Repeatability The repeatability of both the carbon and hydrogen stable isotopic values of a series of well resolved PAHs in F2 was investigated by extracting coal tar D7 six times and establishing 95% confidence intervals for δ13c and δd. The GC IRMS procedure had to be modified slightly to account for exceptionally high levels of

5 naphthalene in this sample using a high split ratio to prevent overloading and damage to the reactor. The remaining PAHs were analysed in a separate run at a lower split ratio with the naphthalene peak sent to waste. The GC c IRMS chromatogram excluding the naphthalene (N) peak is presented in Figure 1(c). The isotopic values of naphthalene were analysed separately. The 95% confidence intervals for the δ13c were all found to be between 0.2 and 0.5, which are within the range of the instrumental precision and confirmed good precision and repeatability of the extraction method (Table 1). Similarly, the 95% confidence interval for the δd were found to be around 1 or 2 for the 14 PAHs that could be measured (the signal for the higher molecular weight PAHs (Indeno(123 cd)pyrene, dibenzo(a,h)anthracene, Benzo(ghi)perylene) were too low to be measurable for hydrogen isotopes) except for chrysene for which the 95% confidence interval was 13 (Table 1). In three out of six repetitions of the extraction, the δd of chrysene was measured around 28 and in the three others it was measured at around 59. Given the extraction conditions (pressure and temperature), it is unlikely that the chrysene would exchange its aromatic hydrogen atoms with the solvent, so this discrepancy in signature could be due either to non reproducible isotopic fractionation, which does not seem likely as there is a clear cluster of two values or to differences in the integration of the peak. As it can be seen in Figure 1(c), the peak of chrysene in D7 was relatively small and eluted close to other compounds. With the exception of chrysene, which could potentially present more reliable values in other tar samples, the extraction method could also be deemed precise and repeatable for hydrogen stable isotopes. 3. Stable isotopic fractionation through chemical fractionation. Because a portion of the PAHs was extracted into the first fraction, isotopic fractionation could potentially have occurred with heavy or light molecules being preferentially selected into a particular fraction. A standard solution containing the 16 US EPA priority PAHs in equal concentration was extracted three times through the one step PLE method and the stable isotope values for both hydrogen and carbon were measured: before extraction, in F1 and in F2 to evaluate possible isotopic fractionation associated with the extraction steps alone (Figure 2). In F1, only the PAHs eluting between naphthalene and pyrene (see Table 1) were measurable for carbon stable isotope analysis and only those eluting between naphthalene and anthracene were measurable for hydrogen stable isotope analysis. In F2, the carbon and hydrogen stable isotopic signatures of PAHs between acenaphthylene and benzo(ghi)perylene could be determined. The measured δ13c and δd values for each PAH in each fraction were compared by two tailed homoscedastic Student s t test to the δ13c and δd measured in the stock solution before extraction. For carbon stable isotopic values, only one out of 16 PAHs failed the Student s t test in F1 with a 95% confidence (anthracene) while four failed in F2 (phenanthrene, anthracene, benzo(k)fluoranthene, benzo(a)pyrene). The differences between the δ13c of these PAHs in the stock solution and the fraction ranged between 0.3 and 1.26, with only two above 1 (anthracene in both fractions). Although statistically significant these differences are negligible for the purpose of source apportionment, since any difference in δ13c 1 is not considered conclusive by environmental isotopic scientists14. Authors have used isotopic profiles, where the x axis present the

6 compounds and the y axis their δ value as a visual representation of the isotopic signature of complex samples15. As it can be seen in Figure 1, the isotopic profile of the stock solution is conserved through the extraction process. For the hydrogen stable isotopic values, only the δd of fluorene failed the t test in F1 and in F2 the values for fluorene, fluoranthene and chrysene were statistically different. For fluorene and chrysene, the differences between the δd values from the stock solution and the fraction are minimal (between 3 and 4 ). With the difference in values for fluoranthene in F2 being more significant (43 ), due to two out of the three F2 extracts providing values considerably depleted compared to the stock. As with the carbon values, however, the isotopic profile of the stock solution is preserved after extraction, which is the most crucial factor in source apportionment. 4. Effect of co elution with interferences Because the clean up phase of the proposed extraction is much less stringent than extraction methods usually employed for compound specific analysis of PAHs, it was necessary to evaluate the effect of co elution of PAHs with interfering compounds from the matrix. To evaluate the extent and the effect of co elution on the carbon and hydrogen stable isotope signatures, GCxGC TOFMS was employed. F1 and F2 of two different tars: D7 and D12 were analysed by GCxGC TOFMS using in the first dimension the same capillary column that was used in the GC IRMS for isotope measurements. A mid polarity column (Crossbond diphenyl dimethyl polysiloxane) was placed in the second dimension and any further separation of constituents in the second dimension showed the number of co eluting components, which may contribute to the isotopic signature. As mentioned above, D7 is a tar that was likely produced in a horizontal retort while D12 originated from a CWG site. D12 is expected to contain much more aliphatic compounds susceptible to co elute with the PAHs. Figure 3 presents the contour plots for the F1 and F2 of D7 and D12, it also shows the threedimensional surface plots for the two D12 fractions. The PAHs are the family of compounds eluting as an almost straight line across the chromatographic plan on the contour plot of all fractions and the aliphatic elutes below this line. By visual inspection of the total ion two dimensional chromatogram only, it was apparent that D7 did not contain aliphatic compounds in amount susceptible to affect the stable isotopic signatures of the PAHs. The F1 of D12, on the other hand, showed a very high aliphatic content, that was absent from F2. Because the same column used for the GC IRMS analysis was used in the first dimension of the GCxGC and the oven temperature and pressure programmes were identical, it is possible to directly conclude for the first time on the possible matrix interferences and their influences on the isotopic values. Therefore, when choosing F2 for both samples, visual inspection was enough to demonstrate that aliphatic compounds did not contribute to the interferences to the δ13c and δd values of the PAHs. Within the aromatic compounds, it is possible that co elution with the analysed PAHs might occur. To study the effect of aromatic co elution on the stable isotopic signatures, D7 and D12 were also extracted using a silica gel column after dissolution of the tar in hexane. Three fractions were also produced this way for both coal tars, with a first elution in 100% hexane (F 1), a second elution for aromatics in a mixture of 50% hexane and 50% toluene (F 2)

7 and a final elution in 100% toluene (F 3), which as for F3 did not show any detectable compounds. The aromatics were present in both F 1 and F 2 but for D12 in F 2 only were their concentrations high enough for isotope analysis. δ13c and δd values of the PAHs were compared in F2 and F 2 in both samples. The measurable Δδ13C (δ13c(f2) δ13c(f 2)) were all calculated between 2.1 and 1.6 (Figure 4a). Notably, the δ13c of the 5 PAHs measured in the F 2 of D12 were consistently enriched (between 1.2 and 2.1 ) compared to that of F2. In D7, the F 2 values were generally depleted (up to 1.6 for 1 MeN) but only Δδ13C(1 MeN) was greater than 1. When it was possible to measure them, the ΔδD (δd(f2) δd(f 2)) were all between 1.4 and 6.7, which fall within a range that would be considered not significant for hydrogen values, except for ΔδD(N) in D7 ( 12.5 ) and ΔδH(BaA) in D12 (52.4 ) (Figure 4b). The value for benzo(a)anthracene can be explained by a poor separation with chrysene. The GCxGC chromatography for these fractions was studied to estimate coelution. We have demonstrated previously12 that in GCxGC chromatography configuration, aromatic compounds with similar number of carbon atoms elute in similar times in the first dimension and can be separated in the second dimension. This is particularly relevant to CSIA because compounds with the same number of carbon atoms theoretically have the same response factor in a GC c IRMS system (because each carbon atom produces a CO2 molecule). Although the response factor in the TOF MS in total ion mode of two aromatic compounds with the same number of carbon atoms might be marginally different, comparing the peak heights of a measured PAH and a co eluting compound will be useful to estimate the effects on the carbon isotopic signature. Figure 5 presents various zooms on the GCxGC chromatograms of F2 and F 2. The intensity gradient was set so that the maximum is around the intensity of the measured PAH (or the intensity of the least concentrated PAH when more than one are presented together) and that all compounds with peak heights within 25% of this value will appear red. The lowest intensity was set to a one thousandth of the maximum. This aimed to only highlight the peaks that might affect the stable isotopic signatures. For D7, it appeared that F 2 generally presented cleaner chromatograms than F2 with less potential co elutants. For instance, Figure 5a shows how the values for naphthalene and its two methylsubstituted daughter compounds are likely to be more accurate in F 2 over F2. As stated previously, the mean δ13c of most measured PAHs is enriched in F2 compared to F 2 with only the carbon signature of 1 MeN appeared significantly enriched (>1 ). The methylnaphthalene appeared to co elute with substituted heterocycles, C3 benzofurans with 11 carbon atoms and C1 benzothiophene with 9 carbon atoms. There are very little reported stable isotope values for heterocyclic PAHs in coal tar. Steinbach et al.16 reported values for δ13c of methylbenzofuran from an aquifer situated at a former manufactured gas plants. The values at various site locations were all around 20, and the authors suggested that either there was no biodegradation of the compound occurring or that there was no isotopic effect associated with the degradation. If benzofurans had indeed more enriched values compared to other PAHs, the slightly more enriched values for the naphthalenes in F2 could be explained. The hydrogen signature of naphthalene is also significantly affected but depleted. In the case of the D12 sample, both F2 and F 2 presented high concentrations of interfering compounds with significant intensities. F 2 appeared this time more affected

8 than F2, leading to significantly enriched δ13c values in F 2 (the δh seemingly less affected). Generally, even when the one dimensional chromatogram displayed good baseline separation, the GCxGC chromatogram enabled to demonstrate coelution and it appeared that more interferences lead to more enriched values but only in the case of severe co elution was the isotopic effect significant. Results for D7 also helped confirmed that there is no isotopic effect associated with the PLE since F2 and F 2, which had not been subjected to PLE, presented similar results. While the accuracy of the values for D7 was demonstrated, it is hypothesised that accurate values for D12 would actually be more depleted than measured in F2 because of interferences. D12 is an extreme example of coal tar non aqueous phase liquid, because of its CWG origin, it is closer in composition to a petroleum oil sample17. When its carbon and hydrogen isotopic profiles are compared to these of D7 (Figure 4c and d), it can be seen that they are still carrying information on the origin of the sample. In fact, while the hydrogen values were closely related, the δ13c values, notably of the higher molecular weight PAHs, were significantly depleted. Petroleum oils exhibit lower δ13c values (in the range 28 to 31 ) than parent coal (c.a. 25 )17,18. The carbon stable isotopic signatures of D12 are therefore expected to fall between these two ranges of values. Conclusions We developed a fast method for CSIA of PAHs in coal tar DNAPLs for both carbon and hydrogen values. The method produced reproducible and precise results. The accuracy of the methods was deemed appropriate for samples with high PAHs contents while the δ13c values are possibly enriched in lower PAHs contents samples. The accuracy of the δd was always good for the more concentrated PAHs in a sample. The automated PLE procedure minimises solvent consumption to less than 100 ml per sample and two fractions are produced within 30 minutes. It is more efficient for high throughput analysis of coal tars, for example to evaluate several samples from a same site for source apportionment, compared to more lengthy and complicated routine extraction methods. Using GCxGC, we demonstrated that even in samples that presented a good baseline resolution, the PAHs of interest co eluted with other aromatic compounds; it demonstrated the necessity to check the quality of the extraction and clean up processes (either PLE or more traditional silica gel column) for the more complex samples prior to data interpretation. Samples from the library of coal tar DNAPLs we recently characterised through a newly developed GCxGC TOFMS method for environmental forensic investigations10 12 are currently being analysed for stable carbon and hydrogen isotope values so that the efficacy of both methods for source identification and apportionment can be compared. Experimental Section 1. Samples and Standards Coal tar samples were obtained from FMGP sites within the UK. All samples were obtained as free phase coal tar DNAPLs, sealed and stored at 4 C prior to analysis. Coal tar D7 was obtained from a site known to have used high

9 temperature horizontal coal retorts for gas manufacture, which produced a very viscose, dark tar with high aromatic content. Coal tar D12 was obtained from a carburetted water gas (CWG) plant, where additional oil sprays were used to enrich the gas stream, thus producing coal tar with a high aliphatic content and broader range of components. All solvents were of analytical grade, purchased from Fisher Scientific (Loughborough, UK). All standards were supplied by Sigma Aldrich (Gillingham, UK). 2. Fractionation by Accelerated Solvent Extraction Accelerated solvent extraction was performed using an ASE 350 system (Dionex, Camberley, UK) equipped with 10 ml the extraction solvents. The extraction cells were lined with 2 filter papers (to ensure unwanted particulate matter did not collect in the extract) and packed with 3 g silica gel 60 (10% deactivated w/w using deionised water) to provide simultaneous sample extraction, cleanup and fractionation. Approximately 2 g of a homogenised DNAPL/diatomaceous earth (D.E.) mixture was added to the extraction cell and the remaining cell volume was packed with D.E. To allow sample fractionation, three separate ASE methods were employed to sequentially extract the same cell using solvents of increasing polarity. To obtain the first fraction, hexane (50 % cell volume) was used to extract the cell. The oven and static times were switched off to allow the solvent to flow straight through the cell and encourage only the aliphatic portion to elute. The second fraction was eluted with hexane:toluene in a 9:1 ratio (70 % cell volume). The oven temperature was maintained at 50 C with the cells heated for 5 minutes prior to extraction. The final fraction was extracted using toluene (70% cell volume) at 100 C (with 5 minute heating time). All extracts were concentrated to 1 ml prior to analysis using a Büchi Syncore Analyst (Oldham, UK). 3. GC C IRMS Analyses The system used for compound specific carbon isotope analysis comprised of a Trace GC, GC Isolink and Conflo IV interfaces and a Delta V advantage isotope ratio mass spectrometer (all Thermo Fisher Scientific, MA, USA). The gas chromatograph was fitted with a 30 m DB 5 capillary column (0.25mm ID, 0.25μm film thickness) supplied by J&W Scientific. The GC Isolink interface consists of both a high temperature conversion unit (1420 C) for δd measurements and a combustion/oxidation furnace (Ni/Cu reactor; 1020 C) for δ13c measurements. The helium flow was kept constant at 1 ml/min. The initial oven temperature was set to 55 C and held for 2 minutes before the temperature was ramped at 5 C/min to 320 C, with a final temperature hold time of 12 minutes. One microlitre of sample was injected using a Triplus (Thermo Scientific) autosampler. The split ratio varied between 10 and 100 for different extracts in order to obtain a signal size higher than 0.3 V for each of the PAHs investigated. All δ13c and δd values were calculated against references gases of CO2 ( 35.4 ) and H2 ( 246 VSMOW) respectively. Unless otherwise stated, isotopic values (δ) represent means of triplicate analysis, where variations were generally <0.3 for δ13c and <2 for δd. 4. GCxGC TOFMS Analyses

10 All GCxGC TOFMS analyses were performed using a Leco (St. Joseph, Michigan) time of flight mass spectrometer, model Pegasus 4D, connected to an Agilent 7890A gas chromatograph equipped with a Leco thermal modulator. The TOF ion source was fixed at 200 ºC with a detector voltage of 1700 V, applied electron ionization voltage of 70 ev and a scan rate of 200 spectra/second. The column set comprised of a Rxi5Sil MS 30 m x 0.25 mm i.d. x 0.25 µm film thickness) as the primary column and an Rix17 (1.2 m x 0.10 mm i.d. x 0.2 µm film thickness) both supplied by Thames Restek (Buckinghamshire, UK) as the secondary column, connected via a Thames Restek Press tight connector. All extracts were analysed using the same primary oven temperature programme as that of the GC C IRMS analyses, with a secondary oven and modulator temperatures offset of 20 C. The modulation period was 6 seconds with a 1.3 second hot pulse time. Helium was used as the carrier gas, with a flow rate of 1.0 ml/min. An MPS2 twister autosampler (Gerstel, GmbH & Co., Germany) was used to inject one microlitre of sample per run at a split ratio of 1:50 and injection port temperature of 250 C. Acknowledgements We thank the Scottish Funding Council (SFC) Glasgow Research Partnership in Engineering (GRPE) for funding support. Parsons Brinckerhoff is gratefully acknowledged for active support in collecting the coal tar library. The authors also gratefully acknowledge the support of National Grid Property for its assistance with this project. [1] G. Liu et al., Rev. Environ. Contam. Toxicol, 2008, 192, [2] Y. V. Pashin, L. M. Bakhitova, Environ. Health Perspect., 1979, 30, [3] S. D. Emsbo Mattingly P. Boehm., Technical Report , 2003 Electric Power Research Institute. [4] R. P. Philp, Environ. Chem. Letters, 2007, 5, [5] W. Meier Augenstein, J. Chrom A, 1999, 842, [6] A. J. Buczyńska et al., Talanta, 2013, 105C, [7] M. Blessing et al., Anal. Bioanal. Chem., 2008, 390, [8] M. Elsner, J. Environ. Monit., 2010, 12, [9] L. Mazeas, H. Budzinski, Environ. Sci. Technol., 2002, 36, [10] L. A. McGregor et al., J. Chrom A, 2011, 1218, [11] L. A. McGregor et al, Environ. Sci. Technol., 2012, 46, [12] C. Gauchotte Lindsay, J. Chrom A, 2012, 1293, [13] M. C. Graham, STOTEN, 2006, 360, [14] R. P. Philp, E. Jarde in Introduction to Environmental Forensics, Second Edition (Eds: B. L. Murphy, R. D. Morrison), Elsevier B. V,, Amsterdam, 2007, pp [15] L. Mansuy et al., Environ. Sci. Technol., 1997, 31, [16] A. Steinbah et al., Environ. Sci. Technol., 2004, 38, [17] D. Saber et al., Environ. Forensics, 2006, 7, [18] C. McRae et al., Organic Geochem., 1999, 30, Received: ((will be filled in by the editorial staff)) Published online: ((will be filled in by the editorial staff))

11 Figure Legends Figure 1. (a) and (b) GC MS chromatograms of F1 (red trace) and F2 (black trace) of samples D7 and D12 respectively. (c) Chromatogram obtained by GC c IRMS for sample D7 with naphthalene peak cut off. Figure 2. Carbon (top) and Hydrogen (bottom) stable isotopic profiles for 16 EPA PAHs standard solution. Figure 3. Total ion extract contour plot chromatograms for sample D7, F1 (a) and F2 (b). Total ion extract contour plot chromatograms for sample D12, F1 (c) and F2 (d). (c ) and (d ) are the equivalent surface plot chromatograms for sample D12. Figure 4. Δδ 13 C (a) and ΔδD (b) measuring the difference in isotopic values between F2 and F 2 in samples D7 and D12, error bars are the 95% confidence intervals calculated through error propagation. δ 13 C (c) and δd (d) isotopic profiles of samples D7 and D12 for F2. Figure 5. Aromatic co elutions in various fractions. Comparison of GCxGC chromatograms between the F2 and F 2 of D7 for (a) the separation of naphthalene (N) and the two methylnaphathalene (2 MeN and 1 MeN), (b) acenaphthylene (ACY) and (c) fluorene (FLU), phenanthrene (PHE) and anthracene (ANT). Comparison of GCxGC chromatograms between the F2 and F 2 of D12 for (d) a series of priority PAHs (between fluorene and pyrene)

12 Table 1. Mean δ 13 C and δh values for 18 PAHs in 6 extractions of sample D7 (F2 only). PAHs # δ 13 C 95% CI [a] δh 95% CI [a] ( ) ( ) ( ) ( ) Naphthalene N methylnaphtahlene MeN methylnaphthalene MeN Acenaphthylene Acy Acenaphthene Ace Fluorene Flu Phenanthrene Phe Anthracene Ant Fluoranthene Flt Pyrene Pyr Benzo(a)anthracene BaA Chrysene Chr Benzo(b)fluoranthene+ Benzo(k)fluoranthene [b] Benzo(a)pyrene BbF+ BkF BaP Indeno(123-cd)pyrene +dibenzo(a,h)anthracene [b] Benzo(ghi)perylene IP+ DBA BP [a] CI= confidence interval; [b] these compounds co-elute

13 Figure 1. (a) and (b) GC-MS chromatograms of F1 (red trace) and F2 (black trace) of samples D7 and D12 respectively. (c) Chromatogram obtained by GC-c-IRMS for sample D7 with naphthalene peak cut-off.

14 Figure 2. Carbon (top) and Hydrogen (bottom) stable isotopic profiles for 16 EPA PAHs standard solution.

15 (a) (c) (c ) aliphatic region (b) (d) (d ) aromatics Figure 3. Total ion extract contour plot chromatograms for sample D7, F1 (a) and F2 (b). Total ion extract contour plot chromatograms for sample D12, F1 (c) and F2 (d). (c ) and (d ) are the equivalent surface plot chromatograms for sample D12.

16 (a) (c) (b) (d) Figure 4. δ 13 C (a) and δd (b) measuring the difference in isotopic values between F2 and F 2 in samples D7 and D12, error bars are the 95% confidence intervals calculated through error propagation. δ 13 C (c) and δd (d) isotopic profiles of samples D7 and D12 for F2.

17 Entry for the Table of Contents (Please choose one layout) Layout 1: Is it really clean? A novel extraction method for polycyclic aromatic hydrocarbons in coal tare non aqueous phase liquids using pressurized liquid extraction is described. Comprehensive two dimensional gas chromatography was used to evaluate possible interferences in the sample that could affect compound specific stable isotope analysis of the polycyclic aromatic hydrocarbons. Keywords: Comprehensive Two Dimensional Gas Chromatography Compound Specific Stable Isotope Analysis Polycyclic Aromatic Hydrocarbons Environmental Forensics Pressurised Liquid Extraction

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil Che Jinshui, 1 Deng Guifeng, 1 Liang Lina, 1 and Aaron Kettle, 2 1 Thermo Fisher Scientific (China)

More information

Coal Tar Forensics. Russell Thomas - WSP/PB Chris Gallacher and Robert Kalin - University of Strathclyde. YCLF February 2017

Coal Tar Forensics. Russell Thomas - WSP/PB Chris Gallacher and Robert Kalin - University of Strathclyde. YCLF February 2017 Coal Tar Forensics Russell Thomas - WSP/PB Chris Gallacher and Robert Kalin - University of Strathclyde YCLF February 2017 WHAT IS COAL TAR? 2 A by-product of gas manufacturing & coke making Complex mixture

More information

This project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission

This project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission This project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission cannot be held responsible for any use which may be made

More information

Environmental Forensic Principals for Sources Allocation of Polycyclic Aromatic Hydrocarbons

Environmental Forensic Principals for Sources Allocation of Polycyclic Aromatic Hydrocarbons Investigate Integrate Innovate Environmental Forensic Principals for Sources Allocation of Polycyclic Aromatic Hydrocarbons October 2008 Presented by: Gwen O Sullivan, Erik Martin and Court D. Sandau Presentation

More information

Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS

Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS UCT Part Numbers: ECQUUS2-MP (4 g of muffled anh. MgSO 4 and 2 g of NaCl) ECPAHFR50CT (50 ml centrifuge tubes, PAHs removed)

More information

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Anila I. Khan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 243 Key Words TraceGOLD fast GC analysis

More information

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS 1.0 SCOPE AND APPLICATION 1.1 Method 8100 is used to determine the concentration of certain polynuclear aromatic hydrocarbons (PAH). Table 1 indicates compounds

More information

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms Application Note Author Laura Provoost Agilent Technologies, Inc. Introduction In multi-residue analysis different groups

More information

The direct effect of the harbour. micropollutant concentration. Workshop Characterization of atmospheric pollution in harbour areas 26 June 2013

The direct effect of the harbour. micropollutant concentration. Workshop Characterization of atmospheric pollution in harbour areas 26 June 2013 pollution in harbour areas 26 June 2013 The direct effect of the harbour of Brindisi on organic micropollutant concentration Elena Gregoris, Andrea Gambaro Institute for the dynamics of the environmental

More information

Rely on Rxi -PAH Columns

Rely on Rxi -PAH Columns Rely on Rxi -PAH Columns to Ensure Successful Polycyclic Aromatic Hydrocarbon (PAH) Analysis Optimized Efficiency, Selectivity, and Robustness Let You: Report accurate results with speed and confidence.

More information

Sensitive and rapid determination of polycyclic aromatic hydrocarbons in tap water

Sensitive and rapid determination of polycyclic aromatic hydrocarbons in tap water APPLICATION NOTE 70923 Sensitive and rapid determination of polycyclic aromatic hydrocarbons in tap water Authors Chen Jing, Dai Zhenyu, Xu Qun, and Liang Lina, Thermo Fisher Scientific, Shanghai, People

More information

The Effect of Unresolved Complex Mixtures (UCM) on Isotopic Profile of Aromatic Hydrocarbons

The Effect of Unresolved Complex Mixtures (UCM) on Isotopic Profile of Aromatic Hydrocarbons International Journal of Chemistry and Applications. ISSN 0974-3111 Volume 3, Number 1 (2011), pp. 49-54 International Research Publication House http://www.irphouse.com The Effect of Unresolved Complex

More information

PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices

PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices Food Quality and Environmental Author Ken Lynam Agilent Technologies, Inc. 280 Centerville Road Wilmington, DE 19808 Abstract

More information

Determination of 24 PAHs in Drinking Water

Determination of 24 PAHs in Drinking Water Determination of 24 PAHs in Drinking Water Application Note Food Testing and Agriculture Authors M.C. Díaz Ramos, A. Suárez, A. Rúbies, and R. Companyó Laboratori de l Agencia de Salut Publica de Barcelona

More information

ENVIRONMENTAL analysis

ENVIRONMENTAL analysis ENVIRONMENTAL analysis Analyzing Wastewater Effluents for PAH s and PBDE s Using the Agilent 7000 Triple Quadrupole GC/MS Solutions for Your Analytical Business Markets and Applications Programs Authors

More information

The Suite for Environmental GC Analysis

The Suite for Environmental GC Analysis The Suite for Environmental GC Analysis SGE Environmental GC Columns Performance Selectivity Delivery Promise www.sge.com SGE Environmental GC Columns The Suite for Environmental GC Analysis SGE GC Columns

More information

SPE AND GC MS INVESTIGATION OF ORGANIC CONTAMINANTS IN ATMOSPHERIC PRECIPITATION

SPE AND GC MS INVESTIGATION OF ORGANIC CONTAMINANTS IN ATMOSPHERIC PRECIPITATION ACTA CHROMATOGRAPHICA, NO. 17, 2006 SPE AND GC MS INVESTIGATION OF ORGANIC CONTAMINANTS IN ATMOSPHERIC PRECIPITATION M. J. Fabiańska *, U. Skręt, and W. E. Krawczyk Department of Earth Science, University

More information

Selection of a Capillary

Selection of a Capillary Selection of a Capillary GC Column - Series 3 Mark Sinnott Application Engineer March 19, 2009 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector

More information

Supporting Information

Supporting Information 1 Supporting Information 2 3 4 5 6 7 8 9 1 11 12 13 14 MANUSCRIPT TITLE: AUTHORS: ADDRESS: Sediment Records of Polycyclic Aromatic Hydrocarbons (PAHs) in the Continental Shelf of China: Implications for

More information

Application Note. Agilent Application Solution Analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection.

Application Note. Agilent Application Solution Analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection. Agilent Application Solution Analysis of PAHs in soil according to EPA 3 method with UV and fluorescence detection Application Note Environmental Authors Sonja Volk, Angelika Gratzfeld-Huesgen Agilent

More information

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution Application Note Abstract Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution Page 1 Polycyclic Aromatic Hydrocarbons (PAHs) are a large group of organic compounds

More information

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF Analysis of Biomarkers in Crude Oil Using the Agilent 7 GC/Q-TOF Application Note Petrochemical and Environmental Authors Frank David Research Institute for Chromatography, Kennedypark 6, B-85 Kortrijk,

More information

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Analysis of Trace (mg/kg) Thiophene in Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Petrochemical Authors James D. McCurry and Bruce D. Quimby Agilent Technologies

More information

is given for the isotopic fingerprinting methodology.

is given for the isotopic fingerprinting methodology. ADVANTAGES OF COUPLING THE FINGERPRINTING AND BIOCHEMICAL TECHNIQUES IN CONTAMINATION ANALYSIS By Ilaria Pietrini Ph. D. Student at Politecnico di Milano ilaria.pietrini@mail.polimi.it Introduction Thousands

More information

Selection of a Capillary GC Column

Selection of a Capillary GC Column Selection of a Capillary GC Column Mark Sinnott Application Engineer March 13, 2008 Page 1 Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer

More information

Applications of Forensic Chemistry to Environmental Work

Applications of Forensic Chemistry to Environmental Work Applications of Forensic Chemistry to Environmental Work Diane L. Saber, Ph.D. Gas Technology Institute 1700 S. Mount Prospect Road Des Plaines, IL 60018, USA Abstract Recent trends in environmental remediation

More information

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS Thermo Scientific ConFlo IV Universal Interface Continuous Flow Interface Isotope Ratio MS 3 ConFlo IV Universal Interface for Continuous Flow Isotope Ratio MS The development of Continuous Flow carrier

More information

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results P EGAU 4D GCxGC TFM Delivering the Right Results LEC s P EGAU 4D GCxGC-TFM The Ultimate Analytical Instrument Pioneering GCxGC technology, combined with the Pegasus TFM and ChromaTF software provides today

More information

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples AppNote 2/2 Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples Pat Sandra Department of Organic Chemistry, University of Gent, Krijgslaan 281 S4, B-9 Gent, Belgium Erik Baltussen

More information

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs) Stir Bar Sorptive Extraction Analysis of PAHs in Aqueous Solution: Using a polymer based technique to pre-concentrate polyaromatic hydrocarbons for analysis by GC-MS. Background: Polyaromatic hydrocarbons

More information

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY Page 1 of 13 CIPAC/4105/R GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY Prepared for CIPAC by Dr M J Tandy*, P M Clarke and B White (UK) The rapid

More information

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014 Developing Large Volume Injection (LVI) in Split / Splitless Inlets Philip J. Koerner Phenomenex Inc. NEMC 2014 Goal To produce a method that provides the largest response of analytes that will produce

More information

MEASUREMENT OF DRY DEPOSITION AMOUNT OF PAHS IN ZONGULDAK REGION

MEASUREMENT OF DRY DEPOSITION AMOUNT OF PAHS IN ZONGULDAK REGION Journal of Young Scientist, Volume II, 2014 ISSN 2344-1283; ISSN CD-ROM 2344-1291; ISSN Online 2344-1305; ISSN-L 2344 1283 MEASUREMENT OF DRY DEPOSITION AMOUNT OF PAHS IN ZONGULDAK REGION Eren KARAKAVUZ

More information

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor Application Note Pesticides Authors Charlie Spanjers and Paul Dauenhauer University of Minnesota, Twin Cities

More information

Volatile organic compounds (VOCs):

Volatile organic compounds (VOCs): Volatile organic compounds (VOCs): Organic chemicals with a high vapour pressure at room temperature. High vapour pressure results from a low boiling point. The World Health Organization (WHO) defined

More information

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS PAGE: 1 of 14 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY CONTENTS 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS

More information

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary. Application Note 36720111 Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary PLOT Column Keywords Pulsed Flame Photometric

More information

Determination of Polycyclic Aromatic Hydrocarbons (PAH) Adsorbed on Soot Formed in Pyrolysis of Acetylene at Different Temperatures

Determination of Polycyclic Aromatic Hydrocarbons (PAH) Adsorbed on Soot Formed in Pyrolysis of Acetylene at Different Temperatures Determination of Polycyclic Aromatic Hydrocarbons (PAH) Adsorbed on Soot Formed in Pyrolysis of Acetylene at Different Temperatures Nazly E. Sánchez, Alicia Callejas, Ángela Millera, Rafael Bilbao and

More information

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace_Rev3 Introducing

More information

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation Introduction Fire investigation involves many different types of analyses from crime scene

More information

Application Note. Abstract. Authors. Environmental

Application Note. Abstract. Authors. Environmental GC/MS Analysis of European Union (EU) Priority Polycyclic Aromatic Hydrocarbons (PAHs) using an Agilent J&W DB-EUPAH GC Column with a Column Performance Comparison Application Note Environmental Authors

More information

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling Andrea Caruso and Massimo Santoro, Thermo Fisher Scientific, Milan, Italy Application Note 1316 Key

More information

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products Bruno Veyrand, Aline Brosseaud, Philippe Marchand, Fabrice Monteau, François Andre,

More information

Organochlorine Pesticides by GCxGC-ECD

Organochlorine Pesticides by GCxGC-ECD Organochlorine Pesticides by GCxGC-ECD LECO Corporation; Saint Joseph, Michigan USA Key Words: GCxGC-ECD, Environmental, Quantification 1. Introduction United States Environmental Protection Agency Method

More information

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System Application Note Residual Solvent Analysis of USP Method Residual Solvents on the Agilent 889 GC System Author Lukas Wieder, Jie Pan, and Rebecca Veeneman Agilent Technologies, Inc. 8 Centerville Road

More information

JWH-018 and JWH-022 as Combustion Products of AM2201

JWH-018 and JWH-022 as Combustion Products of AM2201 JWH-018 and JWH-022 as Combustion Products of AM2201 The emergence of synthetic cannabinoids continues to prove challenging to the forensic scientist. As the initially popular compounds, such as JWH-018

More information

Compatibility of Surfactants and Thermally Activated Persulfate for Enhanced. Subsurface Remediation

Compatibility of Surfactants and Thermally Activated Persulfate for Enhanced. Subsurface Remediation Compatibility of Surfactants and Thermally Activated Persulfate for Enhanced Subsurface Remediation Li Wang, Libin Peng, Liling Xie, Peiyan Deng, Dayi Deng* School of Chemistry and Environment, South China

More information

Appendix 1: Polycyclic Aromatic Compounds: Nomenclature and Analysis

Appendix 1: Polycyclic Aromatic Compounds: Nomenclature and Analysis Appendix 1: Polycyclic Aromatic Compounds: Nomenclature and Analysis This appendix provides an explanation for and definition of the terms that have been used to describe polycyclic aromatic compounds.

More information

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at

More information

Determination of Hydrocarbon Components in Petroleum Naphthas

Determination of Hydrocarbon Components in Petroleum Naphthas Determination of Hydrocarbon Components in Petroleum Naphthas LECO Corporation; Saint Joseph, Michigan USA Key Words: GC-TOFMS, Petrochemical, Naphtha, Deconvolution, Retention Index 1. Introduction The

More information

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column Frank L. Dorman, Gary B. Stidsen, Chris M. English and Lydia Nolan Restek Corporation, Bellefonte,

More information

Introduction. Chapter 1. Learning Objectives

Introduction. Chapter 1. Learning Objectives Chapter 1 Introduction Learning Objectives To understand the need to interface liquid chromatography and mass spectrometry. To understand the requirements of an interface between liquid chromatography

More information

Facility: Mansfield Revision 3. Title: PAHs by SPME Page 1 of 11

Facility: Mansfield Revision 3. Title: PAHs by SPME Page 1 of 11 Title: PAHs by SPME Page 1 of 11 Determination of Parent and Alkyl Polycyclic Aromatics in sediment Pore Water Using Solid-Phase Microextraction and Gas Chromatography/Mass Spectrometry in Selected Ion

More information

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Application Note # CA 284780 Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Abstract The analysis of semi-volatile organic compounds

More information

CALIBRATION OF GC/MS METHOD AND VALIDATION OF THE MODIFIED SAMPLE PREPARATION FOR DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS

CALIBRATION OF GC/MS METHOD AND VALIDATION OF THE MODIFIED SAMPLE PREPARATION FOR DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS Journal Ivan of Givechev, Chemical Dancho Technology Danalev, and Spaska Metallurgy, Yaneva, 53, Dimitar 4, 2018, Tanev 717-724 CALIBRATION OF GC/MS METHOD AND VALIDATION OF THE MODIFIED SAMPLE PREPARATION

More information

Chemical Fingerprinting and Biomarkers (Hydrocarbon Forensics)

Chemical Fingerprinting and Biomarkers (Hydrocarbon Forensics) Chemical Fingerprinting and Biomarkers (Hydrocarbon Forensics) April 19, 2018 Kesavalu M. Bagawandoss, Ph.D., J.D. Laboratory Director Copyright 2018TestAmerica. All rights reserved. Agenda Introduction

More information

The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane

The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane Jarl Snider, D. J. Hotnisky, Kristi Sellers, Dinesh V. Patwardhan Ph. D. Restek Corporation www.restekcorp.com

More information

PAHs in Parking Lot Sealcoats. Performance Study. Asphalt Based. Coal Tar Sealcoat Sealcoat. Sealcoat. Scrapings. Asphalt Based.

PAHs in Parking Lot Sealcoats. Performance Study. Asphalt Based. Coal Tar Sealcoat Sealcoat. Sealcoat. Scrapings. Asphalt Based. PAHs in Parking Lot s Sitelab Corporation Visit: site-lab.com USA: 978-363-99 Performance Study PAHs in Parking Lot s Page 1 of 5 There is growing concern over the use of sealcoating products used on driveways,

More information

Andrei Medvedovici, Florina Micăle, Florentin Tache

Andrei Medvedovici, Florina Micăle, Florentin Tache Andrei Medvedovici, Florina Micăle, Florentin Tache Department of Analytical Chemistry, Faculty of Chemistry, University of Bucharest, # 90-92 Panduri Ave., Bucharest-050663, Romania; Fax no. + 40214102279;

More information

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID Asian Journal of Chemistry Vol. 21, No. 3 (2009), 1739-1746 Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID PRAVEEN KUMAR BALIYAN*, R.P.

More information

Katherine K. Stenerson, Michael Ye, Michael Halpenny, Olga Shimelis, and Leonard M. Sidisky. Supelco, Div. of Sigma-Aldrich Bellefonte, PA USA

Katherine K. Stenerson, Michael Ye, Michael Halpenny, Olga Shimelis, and Leonard M. Sidisky. Supelco, Div. of Sigma-Aldrich Bellefonte, PA USA New Analytical Tools for the Determination of Persistent Organic Pollutants (POPs) in Fatty Food and Beverage Matrices Using QuEChERS Extraction/Cleanup and Gas Chromatography (GC) Analysis Katherine K.

More information

Tar measurement by the Solid Phase Adsorption (SPA) method

Tar measurement by the Solid Phase Adsorption (SPA) method Tar measurement by the Solid Phase Adsorption (SPA) method A.J. Grootjes Presented at the 19th European Biomass Conference and Exhibition (EU BC&E), ICC Berlin, Germany (Conference 6-10 June 2011 - Exhibition

More information

Method 8270C PAH. FD- Field Duplicate Samples

Method 8270C PAH. FD- Field Duplicate Samples Mr. John Rendall Maine Yankee 321 Old Ferry Road Wiscasset, Maine 04578 RE: Project No.: Maine Yankee Sediment Samples Lab Name: Katahdin Analytical Services, Westbrook, Maine Site Name: Maine Yankee Nuclear

More information

Reviewing Material Safety Data Sheets to Verify Significant Drinking Water Threats

Reviewing Material Safety Data Sheets to Verify Significant Drinking Water Threats Reviewing Material Safety Data Sheets to Verify Significant Drinking Water Threats 1 INTRODUCTION When attempting to verify the existence of a Significant Drinking Water Threat (SDWT) related to the handling

More information

Get Selective. By Jaap de Zeeuw

Get Selective. By Jaap de Zeeuw 34 Get Selective Modern narrow bore columns have made chromatographers lazy when it comes to stationary phase selection. Here s how getting back to basics in gas chromatography by using selectivity can

More information

Polycyclic Aromatic Hydrocarbons in Water by GC/MS PBM

Polycyclic Aromatic Hydrocarbons in Water by GC/MS PBM Organics Revision Date: July 10, 2017 Polycyclic Aromatic Hydrocarbons in Water by GC/MS PBM Parameter Analytical Method Introduction Method Summary MDL(s) and EMS Analyte Codes Polycyclic Aromatic Hydrocarbons

More information

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note. Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID Application Note Volatile Organic Compounds (VOCs) Author Andrew Jones Activated

More information

Potassium permanganate as an oxidant in the remediation of soils polluted by Bonny light crude oil

Potassium permanganate as an oxidant in the remediation of soils polluted by Bonny light crude oil Sky Journal of Soil Science and Environmental Management Vol. 3(2), pp. 4-19, February, 2014 Available online http://www.skyjournals.org/sjssem ISSN 2315-8794 2014 Sky Journals Full Length Research Paper

More information

Environmental Forensics

Environmental Forensics Environmental Forensics N O T E S Volume 4 28 Attention: Webinar Announcement Technical Approaches for Apportioning Liability and Allocating Environmental Costs December 1, 28 click here for more information

More information

TECHNICAL MEMORANDUM June 16, 2011

TECHNICAL MEMORANDUM June 16, 2011 TECHNICAL MEMORANDUM June 16, 2011 Tier 1 Remedial Investigation Results and Tier 2 Sampling Plan Former Salinas Manufactured Gas Plant To: Mr. Henry Chui, Department of Toxics Substances Control From:

More information

Analysis of Polycyclic Aromatic Hydrocarbons in Soil with Agilent Bond Elut HPLC-FLD

Analysis of Polycyclic Aromatic Hydrocarbons in Soil with Agilent Bond Elut HPLC-FLD Analysis of Polycyclic Aromatic Hydrocarbons in Soil with Agilent Bond Elut HPLC-FLD Application Note Environmental Authors Bellah O. Pule, Lesego C. Mmualefe, Nelson Torto Department of Chemistry Rhodes

More information

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes Application Note Environmental Authors Ken Lynam and Doris Smith Agilent Technologies, Inc. 2850 Centerville Road Wilmington,

More information

*

* Supporting information: ACTIVATED CARBON AND BIOCHAR AMENDMENTS DECREASE POREWATER CONCENTRATIONS OF POLYCYCLIC AROMATIC HYDROCARBONS (PAHs) IN SEWAGE SLUDGES Patryk Oleszczuk 1,2*, Sarah Hale 1, Johannes

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

BP1 PONA BPX1. GC Capillary Columns BP1 PONA and BPX1

BP1 PONA BPX1. GC Capillary Columns BP1 PONA and BPX1 GC Capillary Columns 100% Dimethyl Polysiloxane GC Columns and Applications ID (mm) Film Thickness (µm) Length (m) Temperature Limits ( C) Part No. 0.32 0.5 60-60 to 320/340 054069 0.32 1 60-60 to 320/340

More information

VGA-100 Instrument Detection Limits and Linearity

VGA-100 Instrument Detection Limits and Linearity VGA-100 Instrument Detection Limits and Linearity The VGA-100 is the world s first benchtop vacuum ultraviolet (VUV) spectrometer for gas chromatography (GC). It is a universal GC detector that provides

More information

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles LECO Corporation; Saint Joseph, Michigan USA Key Words: GC-TOFMS, GC-MS, Pegasus BT, HS-SPME,

More information

Hypersil BDS Columns TG 01-05

Hypersil BDS Columns TG 01-05 TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide

More information

Defense Technical Information Center Compilation Part Notice

Defense Technical Information Center Compilation Part Notice UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADP012132 TITLE: Fuels Combustion Research: Supercritical Fuel Pyrolysis DISTRIBUTION: Approved for public release, distribution

More information

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A Application Note 19060203 Keywords Coffee Essential Oil Flavor Fragrance Gas Chromatograph (GC) Sulfur Compounds Abstract Sulfur compounds

More information

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS Application Note #1820230 Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS GC-MS Introduction USEPA Method 8270 [1] for semivolatiles is is used by by laboratories to measure

More information

COMPARATIVE HYDROCARBON ANALYSIS OF COSDENOL 180, RB SOLVENT 200B, AND CPCHEM NAPHTHALENE SAMPLES

COMPARATIVE HYDROCARBON ANALYSIS OF COSDENOL 180, RB SOLVENT 200B, AND CPCHEM NAPHTHALENE SAMPLES FINAL REPORT COMPARATIVE HYDROCARBON ANALYSIS OF COSDENOL 180, RB SOLVENT 200B, AND CPCHEM NAPHTHALENE SAMPLES R. Gieleciak, C. Fairbridge, C. Lay and D. Hager CanmetENERGY DEVON Work performed for: CanmetENERGY,

More information

Identifying Disinfection Byproducts in Treated Water

Identifying Disinfection Byproducts in Treated Water Identifying Disinfection Byproducts in Treated Water Jonathan D. Byer, LEC Corporation; Saint Joseph, Michigan USA Susan D. Richardson, University of South Carolina; Columbia, South Carolina USA 1. Introduction

More information

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS Application Note: 56 Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS Yang Shi, Catherine Lafontaine, Matthew Berube, John Fink, François Espourteille Thermo

More information

Understanding Gas Chromatography

Understanding Gas Chromatography Understanding Gas Chromatography What is Really Going on Inside the Box? Simon Jones GC Applications Engineer Page 1 Group/Presentation Title Month ##, 200X ?? K? Page 2 Typical GC System Gas supply Injector

More information

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011 ?? Kβ? Page 1 Typical GC System Gas supply Injector Detector Data handling GAS Column Oven Page 2 CARRIER GAS Carries the solutes down the column Selection and velocity influences efficiency and retention

More information

Author. Abstract. Introduction

Author. Abstract. Introduction Improved Performance for the Analysis of Aromatics in Gasoline by ASTM Method D5769 Using the Agilent 5973 inert Gas Chromatography/Mass Spectrometry System Application Author James D. McCurry Agilent

More information

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column Application Note Environmental Author Doris Smith and Kenneth Lynam Agilent Technologies, Inc. 285 Centerville

More information

The Theory of HPLC. Quantitative and Qualitative HPLC

The Theory of HPLC. Quantitative and Qualitative HPLC The Theory of HPLC Quantitative and Qualitative HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference

More information

EL608. Deodorants [EL /1/ ]

EL608. Deodorants [EL /1/ ] EL608. Deodorants [EL608-2004/1/2004-125] 1. Scope The criteria shall apply to the chemical deodorant which is used in closed or stuffy space (hereinafter referred to as close space ), or in opened space

More information

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS 1. List two advantages of temperature programming in GC. a) Allows separation of solutes with widely varying retention factors in a reasonable

More information

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer Purchasing a mass spectrometer (MS) is an important investment for a laboratory. When considering instrument platforms, selection

More information

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages Daniela Held, PSS Polymer Standards Service GmbH, Mainz, Germany Gel permeation chromatography/size-exclusion chromatography (GPC/SEC)

More information

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES ROBOKROM 1 TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview ROBOKROM 2 +8 OPERATIONAL MODES HRGC+HRGC-MS HRGC+HPLC-MS STATIC HEAD SPACE PURGE & TRAP SMPE

More information

APPENDIX G. Data Management Rules. Dioxin Data Report Appendix G. Lower Duwamish Waterway Superfund Site: T-117 Early Action Area

APPENDIX G. Data Management Rules. Dioxin Data Report Appendix G. Lower Duwamish Waterway Superfund Site: T-117 Early Action Area APPENDIX G Data Management Rules Data Management Rules G.1 LABORATORY REPLICATE SAMPLES Chemical concentrations obtained from the analysis of laboratory duplicate or replicate samples (two or more analyses

More information

Application of an Analytical Technique for Determining Alkyl PAHs, Saturated Hydrocarbons and Geochemical Biomarkers

Application of an Analytical Technique for Determining Alkyl PAHs, Saturated Hydrocarbons and Geochemical Biomarkers Application of an Analytical Technique for Determining Alkyl PAHs, Saturated Hydrocarbons and Geochemical Biomarkers Chuck Neslund, Manager Specialty Services National Environmental Monitoring Conference

More information

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION. APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Author: Kira. Yang PerkinElmer, Inc. Shanghai, China Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS Introduction

More information

CHAPTER 6 GAS CHROMATOGRAPHY

CHAPTER 6 GAS CHROMATOGRAPHY CHAPTER 6 GAS CHROMATOGRAPHY Expected Outcomes Explain the principles of gas chromatography Able to state the function of each components of GC instrumentation Able to state the applications of GC 6.1

More information

DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS IN SOIL AT AL-NAHRAWAN BRICKS FACTORY Thamera K. M. Al-Rudaini 1 and Israa M.H.

DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS IN SOIL AT AL-NAHRAWAN BRICKS FACTORY Thamera K. M. Al-Rudaini 1 and Israa M.H. Pak. J. Biotechnol. VOL. 15 (2) 445-450 (2018) ISSN Print: 1812-1837 ww.pjbt.org ISSN online: 2312-7791 DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS IN SOIL AT AL-NAHRAWAN BRICKS FACTORY Thamera K.

More information

A Single-Method Approach for the Analysis of Volatile and Semivolatile Organic Compounds in Air Using Thermal Desorption Coupled with GC MS

A Single-Method Approach for the Analysis of Volatile and Semivolatile Organic Compounds in Air Using Thermal Desorption Coupled with GC MS Electronically reprinted from Volume 32 Number 10 OCTOBER 2014 www.chromatographyonline.com A Single-Method Approach for the Analysis of Volatile and Semivolatile Organic Compounds in Air Using Thermal

More information