Total Sulfide, Methylene Blue Method

Size: px
Start display at page:

Download "Total Sulfide, Methylene Blue Method"

Transcription

1 Title: Total Sulfide, Methylene Blue Method Page 1 of 10 Total Sulfide, Methylene Blue Method References: EPA 376.2: Methods for the Chemical Analysis of Water and Wastes, EPA 600/ , SM 4500S2-AD: Standard Methods for the Examination of Water and Wastewater, APHA-AWWA-WPCF, 21 st Edition, EPA 9030B: SW-846, Test Methods for Evaluating Solid Waste: Physical/Chemical Methods, EPA SW-846, Update III, Scope and Application Matrices: This method is applicable to water, wastewater and seawater samples. Definitions: Refer to Alpha Analytical Quality Manual. Sulfide often is present in groundwater, especially in hot springs. Its common presence in wastewaters comes partly from the decomposition of organic matter, sometimes from industrial wastes, but mostly from the bacterial reduction of sulfate. Hydrogen sulfide escaping into the air from sulfide-containing wastewater causes odor nuisances. The threshold odor concentration of H 2 S in clean water is between and 0.25µg/L. H 2 S is very toxic and has claimed the lives of numerous workers in sewers. It attacks metals directly and has indirectly caused serious corrosion of concrete sewers because it is oxidized biologically to H 2 SO 4 on the pipe wall. From an analytical standpoint, three categories of sulfide in water and wastewater are distinguished: Total sulfide includes dissolved H 2 S and HS-, as well as acid-soluble metallic sulfides present in suspended matter. The S -2 is negligible, amounting to less than 0.5% of the dissolved sulfide at ph 12, less than 0.05% at ph 11, etc. Copper and silver sulfides are so insoluble that they do not respond in ordinary sulfide determinations; they can be ignored for practical purposes. Dissolved sulfide is that remaining after suspended solids have been removed by flocculation and settling. Un-ionized hydrogen sulfide may be calculated from the concentration of dissolved sulfide, the sample ph, and the practical ionization constant of H 2 S. The data report packages present the documentation of any method modification related to the samples tested. Depending upon the nature of the modification and the extent of intended use, the laboratory may be required to demonstrate that the modifications will produce equivalent results for the matrix. Approval of all method modifications is by one or more of the following laboratory personnel before performing the modification: Area Supervisor, Department Supervisor, Laboratory Director, or Quality Assurance Officer. This method is restricted to use by or under the supervision of trained analysts. Each analyst must demonstrate the ability to generate acceptable results with this method by performing an initial demonstration of capability, analyzing a proficiency test sample and completing the record of training. After initial demonstration, ongoing demonstration is based on acceptable laboratory performance of at least a quarterly laboratory control sample or acceptable performance from an annual proficiency test sample. A major modification to this procedure requires demonstration of performance. The identification of major method modification requiring performance demonstration is directed by the Quality Assurance Officer and/or Laboratory Director on a case-by-case basis.

2 Title: Total Sulfide, Methylene Blue Method Page 2 of Summary of Method Sulfide is separated from the sample matrix by suspending the sample in a hydrochloric acid solution and vigorous agitation. Hydrogen sulfide gas is released from the sample and collected in a gas scrubbing bottle cotaining sodium hydroxide. The methylene blue method is based on the reaction of sulfide, mild oxidizing agent potassium dichromate, and dimethyl-pphenylenediamine to produce methylene blue. 2.1 Method Modifications from Reference None. 3. Reporting Limits The reported detection limit is 0.1 mg/l. 4. Interferences 4.1 Strong reducing agents interfere in the methylene blue test by preventing formation of the blue color. Thiosulfate at concentrations about 10mg/L may retard color formation or completely prevent it. Sulfide itself prevents the reaction if its concentration is very high, in the range of several hundred milligrams per liter. To avoid the possibility of false negative results, use the antimony method to obtain a qualitative result in industrial wastes likely to contain sulfide but showing no color by the methylene blue method. Iodide, which is likely to be present in oil-field wastewaters, may diminish color formation if its concentration exceeds 2mg/L. Ferrocyanide produces a blue color. 4.2 Eliminate interferences due to sulfite, thiosulfate, iodide, and many other soluble substances (but not ferrocyanide), by precipitating ZnS. 4.3 Interference Removal or Sample Concentration: Put 0.15mL (3 drops) zinc acetate solution into a 100mL glass bottle, fill with sample, and add 0.10mL (2 drops) 6N NaOH solution. Stopper, making sure no air bubbles are present and mix by rotating back and forth vigorously about a transverse axis. Add enough NaOH to produce a ph above 9. Let precipitate settle for 30 minutes. The treated sample is relatively stable and can be held for several hours. However, if much iron is present, oxidation may be fairly rapid. 5. Health and Safety The toxicity or carcinogenicity of each reagent and standard used in this method is not fully established; however, each chemical compound should be treated as a potential health hazard. From this viewpoint, exposure to these chemicals must be reduced to the lowest possible level by whatever means available. A reference file of material safety data sheets is available to all personnel involved in the chemical analysis. Additional references to laboratory safety are available in the Chemical Hygiene Plan. All personnel handling environmental samples known to contain or to have been in contact with municipal waste must follow safety practices for handling known disease causative agents.

3 Title: Total Sulfide, Methylene Blue Method Page 3 of Sample Collection, Preservation, Shipping and Handling 6.1 Sample Collection Take samples with minimum aeration in either a glass or plastic bottle. Fill the bottle completely and cover. Aqueous samples are collected in a 250mL plastic bottle, soil/solid samples are collected in an amber glass container. 6.2 Sample Preservation All samples must be preserved with 2N zinc acetate (Section 8.8) and 6N sodium hydroxide (Section 8.9). Use four drops of 2N zinc acetate solution per 100mL aqueous sample. Adjust the ph to greater than 9.0 with 6N NaOH. 6.3 Sample Shipping No specific requirements. 6.4 Sample Handling Samples are stored refrigerated at 4 ± 2 C. Soil samples are analyzed within a 28-day holding time. Aqueous samples are analyzed within a 7-day holding time. 7. Equipment and Supplies 7.1 Spectrophotometer, Genesys 10vis: For use at a wavelength of 664nm with cells providing light paths of 1cm. 7.2 Test Tubes: 25mL capacity 7.3 Pipets: Glass, volumetric, various volumes 7.4 Volumetric Flasks: 100mL and 1L volumes 7.5 Erlenmeyer Flasks: 125mL volume 7.6 Three-neck Flask: 500mL volume, 24/40 standard taper joints. 7.7 Dropping funnel: 100mL volume, 24/40 joint. 7.8 Purge gas inlet tube: 24/40 joint with coarse frit. 7.9 Purge gas outlet: 24/40 joint reduced to ¼ in. tube Gas scrubbing bottles: 125mL volume, with ¼ inch o.d. inlet and outlet tubes Tubing: ¼ inch o.d. polytetrafluoroethylene (PTFE) or polypropylene Magnetic Stirrer 7.13 Nitrogen gas: 5.0 Ultra pure.

4 Title: Total Sulfide, Methylene Blue Method Page 4 of Nitrogen regulator 7.15 Flowmeter 7.16 Teflon-coated stirring bar 7.17 Analytical Balance: Capable of weighing 0.1g Glass fiber filter disks: 90mm 7.19 Filtration Apparatus: With membrane filter funnel Suction flask 7.21 Vacuum pump 8. Reagents and Standard different sources. Stock Sulfide Solution, approximately 0.05M: Weigh 12 grams of Na 2 S 9H 2 O (Section 8.13) and add to a 1L volumetric flask. Bring to volume with DI water. Mix by swirling gently to prevent oxygen entrapment. Transfer into a 1L amber glass container and store at room temperature. This solution reacts slowly with oxygen but the change is unimportant within a few hours Standardization against thiosulfate solution Immediately after preparation, standardize the Stock Sulfide Solution as follows. Also standardize the Stock Solution if the % recovery falls below 75% Pipet 10mL of 0.025N standard iodine solution (Section 8.5) into each of two 125mL Erlenmeyer flasks Pipet 2mL of sulfide stock standard solution (Section 8.1) into one flask. Pipet 2mL of DI water, as a reagent blank, into the other flask Add 5mL of 6M HCl (Section 8.12) into each flask, swirl slightly, then cover and place in the dark for 5 minutes Titrate each with 0.025N thiosulfate (Section 8.4) until the yellow iodine color fades to a pale straw color. Just before all the iodine has been titrated, add starch indicator (Section 8.6) dropwise to form a pale blue color. Continue the titration with the thiosulfate. The end point is reached when the blue color first disappears.

5 Title: Total Sulfide, Methylene Blue Method Page 5 of Calculate the sulfide concentration as follows: Sulfide (µmol/ml) = ( T blank - T sample ) X N S 2 O mole S µmoles V sample 2 equiv S 2-1 mmole Where: T = volume of titrant used for the blank and sample (ml) N = concentration of S 2 O 3 2- titrant V = volume of sample used (ml), 2mL recommended Calculation: g Na2S. 9H2O in 140-ml DI= 1097mg/l. 8.2 Sulfide 1 Reagent: Available commercially from HACH Company. Store at 4 ± 2. Reagent expires upon manufacturer s specified date. 8.3 Sulfide 2 Reagent: Available commercially from HACH Company. Store at 4 ± 2. Reagent expires upon manufacturer s specified date. 8.4 Sodium Thiosulfate, 0.025N: Purchased commercially prepared and standardized. Store at room temperature, away from light. Expires upon manufacturer s specified date. 8.5 Standard Iodine Solution, approximately 0.025N: Dissolve 25g of potassium iodide (KI) (Section 8.14) in 700mL of DI water in a 1L volumetric flask. Add 3.2g of iodine (Section 8.15). Allow to dissolve. Dilute to 1L with DI water and standarize exactly 20mL of the iodine solution. Titrate with 0.025N sodium thiosulfate (Section 8.4) until the amber floor fades. Add starch indicator solution (Section 8.6) until the solution turns a deep blue. Continue titration drop by drip until the blue color disappears. Prepare solution fresh as needed. Standard Iodine Solution, N; Purchased commercially LCS/ICV/CCV Solution: The sulfide stock soln. (Section 8.1) is diluted with 0.2N NaOH soln.to a concentration at about the mid-point of the calibration curve. 8.6 Starch indicator solution: Purchased commercially prepared. Store at room temperature. There is no expiration date. 8.7 Sulfide Calibration Solutions: These solutions are used to generate the calibration curve in Section Prepare a series of sulfide solutions by diluting the Stock Sulfide Standard second source(section 8.1). These solutions are prepared fresh prior to generating a calibration curve. Into seven 100mL volumetric flasks, pipet 0mL, 0.5mL, 1mL, 2.0mL, 4mL, 6mL and 8mL of Stock Sulfide Solution (Section 8.1). Bring each to volume with 0.2N NAOH Solution. 8.8 Zinc Acetate Solution: Dissolve 220g Zn(C 2 H 3 O 2 ) 2 2H 2 O in 500mL water. This solution is used as the preservative during sampling. Store at room temperature. Solution is stable. 8.9 Sodium Hydroxide Solution, NaOH, 1N and 6N: For 1N NaOH, dissolve 40g NaOH in 1L of DI water. For 6N, dissolve 240g NaOH in 1L of DI water. This solution is used as a preservative during sampling. Store at room temperature. Solution is stable.

6 Title: Total Sulfide, Methylene Blue Method Page 6 of Sodium Hydroxide Solution, NaOH, 0.2N: In a 100mL volumetric flask, pipet 20mL of 1N NaOH (Section 8.8). temperature. Solution is stable. Bring to volume with DI water. Store at room 8.11 HCL Solution, 2N: Add 175mL concentrated HCL (Section 8.16) to 500mL of DI water. Dilute to 1L with DI water. Store at room temperature HCL (50%): Carefully add 250mL of concentrated HCL (Section 8.16) to 250mL DI water. Store at room temperature Na 2 S 9H 2 O: Store at room temperature, out of direct light. Expires one year from date of opening Potassium Iodide (KI): Store at room temperature, away from light. No expiration date Iodine: Store at room temperature, away from light. No expiration date Concentrated HCL: Store at room temperature. 9. Quality Control The laboratory must maintain records to document the quality of data that is generated. Ongoing data quality checks are compared with established performance criteria to determine if the results of analyses meet the performance characteristics of the method. 9.1 Blanks Method Blank: Distill and analyze one Method Blank of DI water per batch of 20 samples or less. The Method Blank results must be less than the Reporting Limit. Refer to Section 12 for any corrective actions ICB/CCB: The ICB/CCB is not distilled. It consists of 0.2N NaOH soln and is analyzed following each ICV/CCV. Results must be less than the Reporting Limit. Refer to Section 12 for any corrective actions. 9.2 Laboratory Control Sample (LCS) Distill and analyze one LCS (Section 8.5.1) per batch of 20 samples or less. % Recovery must be within %. Refer to Section 12 for any corrective actions. 9.3 Initial Calibration Verification (ICV) The ICV is not distilled. It consists of the ICV Standard (Section 8.5.1) and is analyzed after every 10 samples in the batch. % Recovery must be within %. Refer to Section 12 for any corrective actions. 9.4 Continuing Calibration Verification (CCV) The CCV is not distilled. It consists of the CCV Standard (Section 8.5.1) and is analyzed after every 10 samples in the batch. % Recovery must be within %. Refer to Section 12 for any corrective actions. 9.5 Matrix Spike Prepare and analyze one matrix spike per batch of 20 samples or less.

7 Title: Total Sulfide, Methylene Blue Method Page 7 of Laboratory Duplicate Prepare and analyze one sample in duplicate per batch of 20 samples or less. %RPD must be < 25%. Refer to Section 12 for any corrective actions. 9.7 Method-specific Quality Control Samples None. 9.8 Control Limits The laboratory maintains performance records to document the quality of data that is generated. Method accuracy for samples is assessed and records maintained. After the analysis of 20 spiked samples, and 20 laboratory control samples, calculate the average percent recovery (R) and the standard deviation of the percent recovery (S). Control limits for the method parameters are generated. The control limits are calculated based on in-house performance data. The limits are compared to the control limits found in the reference method. 9.9 Method Sequence 10. Procedure Standardize the Stock Sulfide Solution. Generate a calibration curve. Add 1mL Sulfide 1 Reagent to 25mL of sample and swirl gently to mix. Add 1mL of Sulfide 2 Reagent. Wait 5 15 minutes. Read the absorbances of samples and QC samples. Calculate results Initial Calibration Prepare a calibration curve using the selected standards from Section 8.7. Analyze the standards as in Section 10.3 below, and plot concentration vs. absorbance. Determine the slope and the y-intercept. The correlation coefficient must be > Equipment Operation and Sample Processing Sample Preparation Soil samples: Weigh 10 grams of the sample on parafilm and place into the reaction flask with a clean stirbar. Record the weight in the laboratory notebook Aqueous samples: Filter entire sample volume through a 90mm glass fiber filter and rinse with DI water. Place filter into the reaction flask with a clean Teflon stirbar. Record the volume of sample filtered in the laboratory notebook Add 200mL of deaerated 2N HCL Solution (Section 8.11) into the thistle tube, making sure that the stopcock is closed Add 20mL of deaerated 1N NaOH (Section 8.9) and 50mL of deaerated DI to the 250mL collection vessel Assemble the distillation train.

8 Title: Total Sulfide, Methylene Blue Method Page 8 of Connect the thistle flask to the center position of the reaction flask Connect the collection vessel to the left side of the reaction flask, and the impinger tube to the collection vessel. The impinger tube must be below the surface of the NaOH solution. Make sure that all ground glass joints are sealed Connect the Nitrogen gas to the right side of the collection vessel. The gas inlet must be above the surface of the reaction flask solution (about two inches) Making sure that the train is a closed system, purge the train with Nitrogen for 5 minutes. Open the valve on the Nitrogen tank (Section 7.13) and open up the regulator so that 45 psi of Nitrogen is flowing (this will effectively give a flow rate of about 150mL/min) Once the system has been purged for 5 minutes, open the stopcock fully on the thistle tube and release the 2N HCL solution into the reaction vessel. At this point the sample should be stirring. Close the stopcock as soon as all of the 2N HCL solution has been delivered to the reaction flask. Let the reaction progress for 1 hour After one hour has passed, dissemble the train and bring the total volume of the collection vessel to 100mL with deaerated DI Color Development: Transfer 25mL sample to a test tube using a special wide-tip pipet. Add 1.0mL Sulfide 1 reagent (Section 8.2) and swirl to mix. Add 1mL of Sulfide 2 reagent (Section 8.3). Let the reaction continue for 5 minutes. Excessive mixing causes low results by loss of H 2 S as a gas before it has had time to react. The presence of sulfide will be indicated by the appearance of blue color. Color development usually is complete in about 1 minute, but a longer time is often required for fading out of the initial pink color. Wait 5 to 15 minutes and make color comparisons. If zinc acetate was used, wait at least 10 minutes before making a visual color comparison Absorbance Determination: Set the spectrophotometer to a wavelength of 664nm. Zero the instrument with a portion of the blank sample using a 1 cm cell. Read the absorbances of the samples and QC samples and record this information in the laboratory notebook. If the absorbance is greater than the highest standard in the calibration curve, the sample must be diluted with 0.2N NaOH (Section 8.10) and reanalyzed as in Section above. Record in the laboratory notebook any dilutions that are prepared Continuing Calibration See Section Preventive Maintenance An instrument service company calibrates the spectrophotometers on a semi-annual basis. Certificates are kept on file. 11. Calculations Calculate sulfide concentration using the calibration curve generated in Section 10.2: Sulfide (mg/l) = Absorbance y intercept X Dilution factor Slope

9 Title: Total Sulfide, Methylene Blue Method Page 9 of Contingencies for Handling Out-of-Control Data or Unacceptable Data Holding time exceedence and improper preservation are noted on the nonconformance report form. Perform routine preventative maintenance following manufacturer's specification. Record all maintenance in the instrument logbook. Review of standards, blanks and standard response for acceptable performance occurs for each batch of samples. Record any trends or unusual performance on a nonconformance action form. If the CV or LCS recovery of any parameter falls outside the designated acceptance range, the laboratory performance for that parameter is judged to be out of control, and the problem must be immediately identified and corrected. The analytical result for that parameter in the unspiked samples is suspect and is only reported for regulatory compliance purposes with the appropriate nonconformance action form. Immediate corrective action includes reanalyzing all affected samples by using any retained sample before the expiration of the holding time. If the Method Blank result is greater than the reporting limit, and all associated sample results are non-detect, or greater than 10x the concentration of the Method Blank, the data may be reported and a narrative submitted for inclusion on the final report. If associated sample results are positive, but at a concentration less than 10x the concentration of the Method Blank, those samples are redigested and reanalyzed. If the LCS fails acceptance criteria, the entire batch must be redigested and reanalyzed. If there is insufficient sample volume to redigest, then the Client Services Department is notified and the sample results are reported as estimated, with a narrative to be included on the final report. If %RPD for the Duplicate fails acceptance criteria, the non-conformance is narrated and included on the final report. 13. Method Performance 13.1 Method Detection Limit Study (MDL) / Limit of Detection Study (LOD) / Limit of Quantitation (LOQ) The laboratory follows the procedure to determine the MDL, LOD, and/or LOQ as outlined in Alpha SOP/ These studies performed by the laboratory are maintained on file for review Demonstration of Capability Studies Refer to Alpha SOP/08-12 for further information regarding IDC/DOC Generation Initial (IDC) The analyst must make an initial, one-time, demonstration of the ability to generate acceptable accuracy and precision with this method, prior to the processing of any samples Continuing (DOC) The analyst must make a continuing, annual, demonstration of the ability to generate acceptable accuracy and precision with this method.

10 Title: Total Sulfide, Methylene Blue Method Page 10 of Pollution Prevention and Waste Management Refer to Alpha s Chemical Hygiene Plan and Waste Management and Disposal SOP for further pollution prevention and waste management information. 15. Referenced Documents Chemical Hygiene Plan SOP/08-05 MDL/LOD/LOQ Generation SOP/08-12 IDC/DOC Generation SOP/14-01 Waste Management and Disposal SOP 16. Attachments None.

Acid Volatile Sulfides and Simultaneously Extracted Metals in Sediments

Acid Volatile Sulfides and Simultaneously Extracted Metals in Sediments Title: AVS-SEM Page 1 of 8 Acid Volatile Sulfides and Simultaneously Extracted Metals in Sediments Reference: Determination of acid-volatile sulfide and simultaneously-extracted metals in sediments using

More information

ALLOWAY METHOD OUTLINE

ALLOWAY METHOD OUTLINE ALLOWAY METHOD OUTLINE Standard Laboratory Method SM4500-Cl -G Parameter Residual Chlorine & Free Chlorine Method DPD Colorimetric Test Kit Date Issued Originator: Section Supervisor: QA Manager Date:

More information

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method: ALLOWAY METHOD OUTLINE Standard Laboratory Method: SM Parameter: Methylene Blue Method: Colorimetric Reporting Level: Reference: 0.05 mg/l Standard Methods for the Examination Of Water and Wastewater;

More information

Seawater Extraction Procedure for Trace Metals

Seawater Extraction Procedure for Trace Metals Title: Seawater Extraction Page 1 of 10 Seawater Extraction Procedure for Trace Metals References: Danielson, L., B. Magnusson, and S. Westerlund. 1978. An improved metal extraction procedure for the determination

More information

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater. Nitrogen, Ammonia DOC316.53.01078 USEPA 1 Nessler Method 2 Method 8038 0.02 to 2.50 mg/l NH 3 N Reagent Solution Scope and application: For water, wastewater and seawater. Distillation is required for

More information

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater Hach Company TNTplus 835/836 Nitrate Method 10206 Spectrophotometric Measurement of Nitrate in Water and Wastewater Hach Company TNTplus 835/836 Method 10206 Revision 2.2 January 15, 2013 Spectrophotometric

More information

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water Hach Method 1041 Spectrophotometric Measurement of Free Chlorine (Cl ) in Finished Drinking Water Hach Company Method 1041 Revision 1. November 015 Spectrophotometric Measurement of Free Cl in Finished

More information

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows Nitrate DOC316.53.01067 Cadmium Reduction Method Method 8192 0.01 to 0.50 mg/l NO 3 N (LR) Powder Pillows Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific

More information

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis Hach Method 1061 Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis Hach Company Method 1061 Revision 1. December 015 Organic Carbon in Finished

More information

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample.

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample. METHOD 9200 NITRATE 1.0 SCOPE AND APPLICATION 1.1 This method is applicable to the analysis of ground water, drinking, surface, and saline waters, and domestic and industrial wastes. Modification can be

More information

Percent Solids Determination

Percent Solids Determination Title: Percent Solids Page 1 of 10 Percent Solids Determination References: Method 2540G, Standard Methods For the Examination of Water and Wastewater, APHA 18 th edition, 1992. 1. Scope and Application

More information

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE 1.0 SCOPE AND APPLICATION 1.1 This method can be used for measuring total solubilized nitrate in drinking

More information

Method to 0.50 mg/l NH 3 N Powder Pillows

Method to 0.50 mg/l NH 3 N Powder Pillows , 8155 Salicylate Method 1 Scope and Application: For water, wastewater and seawater 1 Adapted from Clin. Chim. Acta., 14, 403 (1966) DOC316.53.01077 Method 8155 0.01 to 0.50 mg/l NH 3 N Powder Pillows

More information

Z/zs. tnitiats: wu\ Z-z* I A. sop-c-102. Determination of Chemical Oxygen Demand. Revision 6. Approval: Effective date: 3. Renewat date: 7lt:,:

Z/zs. tnitiats: wu\ Z-z* I A. sop-c-102. Determination of Chemical Oxygen Demand. Revision 6. Approval: Effective date: 3. Renewat date: 7lt:,: sop-c-102 Determination of Chemical Oxygen Demand Revision 6 Approval: Laborato ry Manager/LQAO/RS O Date Z/zs Date Z-z* I A Renewat date: 7lt:,: Effective date: 3, tnitiats: wu\ Texas lnstitute for Applied

More information

Method to 0.50 mg/l NH 3 N Powder Pillows

Method to 0.50 mg/l NH 3 N Powder Pillows , 8155 Salicylate Method 1 Scope and Application: For water, wastewater and seawater 1 Adapted from Clin. Chim. Acta., 14, 403 (1966) DOC316.53.01077 Method 8155 0.01 to 0.50 mg/l NH 3 N Powder Pillows

More information

Nitrogen, Total Inorganic

Nitrogen, Total Inorganic Nitrogen, Total Inorganic DOC316.53.01090 Titanium Trichloride Reduction Method Method 10021 0.2 to 25.0 mg/l N Test N Tube Vials Scope and application: For water, wastewater and seawater. Test preparation

More information

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Nitrate DOC316.53.01066 Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific

More information

DR/4000 PROCEDURE NITRATE. 2. The display will show:

DR/4000 PROCEDURE NITRATE. 2. The display will show: Method 8192 Powder Pillows DR/4000 PROCEDURE Cadmium Reduction Method LR (0 to 0.50 mg/l NO 3 N) Scope and Application: For water, wastewater and seawater. The estimated detection limit for program number

More information

Shaker Table Extraction

Shaker Table Extraction Title: Shaker Table Extraction Page 1 of 11 Shaker Table Extraction References: This standard operating procedure (SOP) is a performance-based method. This SOP describes the procedure as developed by Alpha

More information

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters) Nitrate, MR DOC316.53.01069 Cadmium Reduction Method Method 8171 0.1 to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters) Scope and application: For water, wastewater

More information

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows Silver DOC316.53.01134 Colorimetric Method Method 8120 0.02 to 0.70 mg/l Ag Powder Pillows Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows

More information

DR/4000 PROCEDURE. IRON, Total

DR/4000 PROCEDURE. IRON, Total Method 8365 Powder Pillows DR/4000 PROCEDURE FerroMo Method* (0 to 1.800 mg/l) Scope and Application: For cooling water containing molybdate-based treatment; digestion is required for determining total

More information

+ H 2 O Equation 1. + NaOH CO 2 Na

+ H 2 O Equation 1. + NaOH CO 2 Na Experiment # 5 VINEGAR: AN FDA INVESTIGATION Objective In this experiment, you will play the role of an FDA analytical chemist, You will verify whether a vinegar manufacturer's quality control lab remains

More information

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows Potassium DOC316.53.01127 Tetraphenylborate Method Method 8049 0.1 to 7.0 mg/l K Powder Pillows Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific information

More information

Experiment 2: Analysis of Commercial Bleach Solutions

Experiment 2: Analysis of Commercial Bleach Solutions Experiment 2: Analysis of Commercial Bleach Solutions I. Introduction The ability of household bleach to remove stains is related to the amount of oxidizing agent in it. The oxidizing agent in bleach is

More information

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials Nitrogen, Total DOC316.53.01085 Persulfate Digestion Method Method 10072 2 to 150 mg/l N (HR) Test N Tube Vials Scope and application: For water and wastewater. Test preparation Instrument-specific information

More information

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials Nitrogen, Total DOC316.53.01086 Persulfate Digestion Method Method 10071 0.5 to 25.0 mg/l N (LR) Test N Tube Vials Scope and application: For water and wastewater. Test preparation Instrument-specific

More information

ASTM Designation: D Standard Test Method for Determination of Iodine Number of Activated Carbon

ASTM Designation: D Standard Test Method for Determination of Iodine Number of Activated Carbon ASTM Designation: D4607-94 Standard Test Method for Determination of Iodine Number of Activated Carbon 1. Scope 1.1 This test method covers the determination of the relative activation level of unused

More information

Oxygen Demand, Chemical

Oxygen Demand, Chemical Oxygen Demand, Chemical DOC316.53.01103 USEPA Reactor Digestion Method Method 10211 1 to 60 mg/l COD (ULR) TNTplus 820 Scope and application: For wastewater, process water, surface water, and cooling water.

More information

Oxygen Demand, Chemical

Oxygen Demand, Chemical Oxygen Demand, Chemical DOC316.53.01104 USEPA Reactor Digestion Method Method 10212 250 to 15,000 mg/l COD (UHR) TNTplus 823 Scope and application: For wastewater and process waters; digestion is required.

More information

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows FILL LINE Method 8155 Salicylate Method 1 Powder Pillows Scope and Application: For water, wastewater, and seawater 1 Adapted from Clin. Chim. Acta., 14, 403 (1966) (0.01 to 0.50 mg/l NH 3 N) Test Preparation

More information

Synthesis and Analysis of a Coordination Compound

Synthesis and Analysis of a Coordination Compound Synthesis and Analysis of a Coordination Compound In addition to forming salts with anions, transition metal cations can also associate with neutral molecules (and ions) through a process called ligation.

More information

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3 , MR, 8171 DOC316.53.01069 Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3 N) Powder Pillows or AccuVac Ampuls Scope and Application: For water, wastewater and seawater Test preparation

More information

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

DR/4000 PROCEDURE NITRATE. Using Powder Pillows DR/4000 PROCEDURE Method 8171 Powder Pillows or AccuVac Ampuls Cadmium Reduction Method MR (0 to 5.0 mg/l NO 3 N) Scope and Application: For water, wastewater and seawater. The estimated detection limit

More information

SOP-C-120 Determination of ph

SOP-C-120 Determination of ph i. Identification of the method a. SM 4500-H + (approved 2011) and EPA 9045C (approved 1997) ii. Applicable matrix or matrices a. Waters or aqueous solutions and suspensions iii. Limits of detection and

More information

Scope and application: For wastewater, seawater, drinking water, surface water and process water.

Scope and application: For wastewater, seawater, drinking water, surface water and process water. Cyanide DOC316.53.01495 USEPA 1 Pyridine Barbituric Acid Method 2 Method 10265 0.01 to 0.60 mg/l CN TNTplus 862 Scope and application: For wastewater, seawater, drinking water, surface water and process

More information

Phenolphthalein and Total Alkalinity Method to 4000 mg/l as CaCO 3 Digital Titrator

Phenolphthalein and Total Alkalinity Method to 4000 mg/l as CaCO 3 Digital Titrator Alkalinity DOC316.53.01166 Phenolphthalein and Total Alkalinity Method 8203 10 to 4000 mg/l as CaCO 3 Digital Titrator Scope and application: For water, wastewater and seawater. Test preparation Before

More information

Sulfide DOC Methylene Blue Method 1 (0 0.70, and mg/l) Method Test procedure

Sulfide DOC Methylene Blue Method 1 (0 0.70, and mg/l) Method Test procedure Methylene Blue Method 1 (0 0.70, 0 7.00 and 0 70.00 mg/l) DOC316.53.01320 Method 10254 Scope and Application: For oil and gas field waters. 1 Adapted from Standard Methods for the Examination of Water

More information

LACTIC ACID. The method is applicable to the determination of lactic acid and lactate salts (Note 2) in light or heavy steepwater.

LACTIC ACID. The method is applicable to the determination of lactic acid and lactate salts (Note 2) in light or heavy steepwater. LACTI.01-1 LACTIC ACID PRINCIPLE SCOPE Lactic acid in steepwater (Note 1) is oxidized to acetaldehyde following treatment with copper sulfate and calcium hydroxide to remove interfering substances. Acetaldehyde

More information

Copper (II) Glycinate Titration

Copper (II) Glycinate Titration Copper (II) Glycinate Titration In this experiment you will standardize (determine the concentration of) a solution of sodium thiosulfate. You will then use that sodium thiosulfate solution to titrate

More information

Spectrophotometric Determination of Ferrocyanide in Effluents

Spectrophotometric Determination of Ferrocyanide in Effluents Spectrophotometric Determination of Ferrocyanide in Effluents ECN-0025-1 INTRODUCTION This method is used to determine the concentration of ferrocyanide ion in photoprocessing solution effluents. The ion

More information

METHOD 9012 TOTAL AND AMENABLE CYANIDE (COLORIMETRIC, AUTOMATED UV)

METHOD 9012 TOTAL AND AMENABLE CYANIDE (COLORIMETRIC, AUTOMATED UV) METHOD 9012 TOTAL AND AMENABLE CYANIDE (COLORIMETRIC, AUTOMATED UV) 1.0 SCOPE AND APPLICATION 1.1 Method 9012 is used to determine the concentration of inorganic cyanide in an aqueous waste or leachate.

More information

Chemistry Determination of Mixed Acids

Chemistry Determination of Mixed Acids Chemistry 3200 Acid-base titration is one of the most common operations in analytical chemistry. A solution containing an unknown amount of ionizable hydrogen can be titrated with a solution of standard

More information

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856 Nickel DOC316.53.01065 Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows

More information

EXPERIMENT 22 SOLUBILITY OF A SLIGHTLY SOLUBLE ELECTROLYTE

EXPERIMENT 22 SOLUBILITY OF A SLIGHTLY SOLUBLE ELECTROLYTE EXPERIMENT 22 SOLUBILITY OF A SLIGHTLY SOLUBLE ELECTROLYTE INTRODUCTION Electrolytes are compounds that are present in solution as ions. They are more likely to be soluble in water than in most other liquids

More information

EXPERIMENT NINE Part I - The Standardization of Thiosulfate Solutions

EXPERIMENT NINE Part I - The Standardization of Thiosulfate Solutions EXPERIMENT NINE Part I - The Standardization of Thiosulfate Solutions In general, thiosulfate solutions are standardized by indirect methods, Primary-standard oxidizing agents such as KIO 3, As 2 O 3,

More information

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ). Method 8194 DR/4000 PROCEDURE Diaminobenzidine Method* (0 to 1.000 mg/l) Scope and Application: For water and wastewater; distillation is required for determining total selenium. See the Distillation procedure

More information

Method 630. The Determination of Dithiocarbamate Pesticides in Municipal and Industrial Wastewater

Method 630. The Determination of Dithiocarbamate Pesticides in Municipal and Industrial Wastewater The Determination of Dithiocarbamate Pesticides in Municipal and Industrial Wastewater The Determination of Dithiocarbamate Pesticides in Municipal and Industrial Wastewater 1. SCOPE AND APPLICATION 1.1

More information

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY 1.0 SCOPE AND APPLICATION 1.1 Method 8032 is used to determine trace amounts of acrylamide monomer (CAS No. 79-06-1) in aqueous matrices. This method may be

More information

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE) METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE) 1.0 SCOPE AND APPLICATION 1.1 This method is applicable to ground water, drinking, surface, and saline waters, and domestic and industrial wastes.

More information

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV Iron, Total DOC316.53.01338 FerroZine Method 1 Method 10264 1 to 100 µg/l Fe (10-cm cell) Reagent Solution Scope and application: For ultrapure water. 1 Adapted from Stookey, L.L., Anal. Chem., 42(7),

More information

Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters)

Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters) Aluminum DOC316.53.01002 Aluminon Method 1 Method 8012 0.008 to 0.800 mg/l Al 3+ (spectrophotometers) Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters) Scope and application: For water and wastewater.

More information

Phosphorus, Total. USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method to 3.50 mg/l PO. Test preparation

Phosphorus, Total. USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method to 3.50 mg/l PO. Test preparation Phosphorus, Total DOC316.53.01121 USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method 8190 0.06 to 3.50 mg/l PO 3 4 (0.02 to 1.10 mg/l P) Test N Tube Vials Scope and application: For water,

More information

Standard Operating Procedure for: Conductivity Using Cole-Parmer Traceable Portable Conductivity Meter. Missouri State University.

Standard Operating Procedure for: Conductivity Using Cole-Parmer Traceable Portable Conductivity Meter. Missouri State University. Standard Operating Procedure for: Conductivity Using Cole-Parmer Traceable Portable Conductivity Meter Missouri State University and Ozarks Environmental and Water Resources Institute (OEWRI) Prepared

More information

Chromium, Total. Alkaline Hypobromite Oxidation Method 1 Method to 0.70 mg/l Cr (spectrophotometers) 0.01 to 0.60 mg/l Cr (colorimeters)

Chromium, Total. Alkaline Hypobromite Oxidation Method 1 Method to 0.70 mg/l Cr (spectrophotometers) 0.01 to 0.60 mg/l Cr (colorimeters) Chromium, Total DOC316.53.01034 Alkaline Hypobromite Oxidation Method 1 Method 8024 0.01 to 0.70 mg/l Cr (spectrophotometers) 0.01 to 0.60 mg/l Cr (colorimeters) Scope and application: For water and wastewater.

More information

Hach Company TNTplus TM Phosphorus Spectrophotometric Measurement of Phosphorus in Water and Wastewater

Hach Company TNTplus TM Phosphorus Spectrophotometric Measurement of Phosphorus in Water and Wastewater Hach Company TNTplus TM Phosphorus Spectrophotometric Measurement of Phosphorus in Water and Wastewater Hach Company TNTplus TM Phosphorus Method 10209/10210/843/844/845 November 2015 Revison 2 Spectrophotometric

More information

Chromotropic Acid Method Method to 30.0 mg/l NO 3 N (HR) Test N Tube Vials

Chromotropic Acid Method Method to 30.0 mg/l NO 3 N (HR) Test N Tube Vials Nitrate, HR DOC316.53.01068 Chromotropic Acid Method Method 10020 0.2 to 30.0 mg/l NO 3 N (HR) Test N Tube Vials Scope and application: For water and wastewater. Test preparation Instrument-specific information

More information

DR/4000 QUATERNARY AMMONIUM COMPOUNDS PROCEDURE. 2. The display will show: 3. Fill a sample cell (the blank) with 25 ml of deionized water.

DR/4000 QUATERNARY AMMONIUM COMPOUNDS PROCEDURE. 2. The display will show: 3. Fill a sample cell (the blank) with 25 ml of deionized water. Method 8337 Powder Pillows DR/4000 TT PROCEDURE QUATERNARY AMMONIUM COMPOUNDS Direct Binary Complex Method (0 to 5.00 mg/l as CTAB) Scope and Application: For cooling tower and pool/spa water. The estimated

More information

Chlorine, Free and Total, High Range

Chlorine, Free and Total, High Range Chlorine, Free and Total, High Range DOC316.53.01490 USEPA DPD Method 1 Method 10069 (free) 10070 (total) 0.1 to 10.0 mg/l Cl 2 (HR) Powder Pillows Scope and application: For testing higher levels of free

More information

Chlorine, Free and Total, Low Range

Chlorine, Free and Total, Low Range Chlorine, Free and Total, Low Range DOC316.53.01450 USEPA DPD Method 1 Method 8021 (free) 8167 (total) 0.02 to 2.00 mg/l Cl 2 (LR) Powder Pillows or AccuVac Ampuls Scope and application: For testing residual

More information

ALLOWAY. Method Outline. Standard Laboratory Method: Total Fluoride via Distillation. Distillation then Specific Ion. Date Issued: 01/04/82

ALLOWAY. Method Outline. Standard Laboratory Method: Total Fluoride via Distillation. Distillation then Specific Ion. Date Issued: 01/04/82 ALLOWAY Method Outline Standard Laboratory Method: SM4500-F - B and SM4500-F-C Parameter: Total Fluoride via Distillation Method: Distillation then Specific Ion Date Issued: 01/04/82 Date Revised: 04/09/02,

More information

Sodium Chloride - Analytical Standard

Sodium Chloride - Analytical Standard Sodium Chloride - Analytical Standard Determination of Arsenic Former numbering: ECSS/CN 312-1982 & ESPA/CN-E-105-1994 1. SCOPE AND FIELD OF APPLICATION The present EuSalt Analytical Standard describes

More information

Mercuric Thiocyanate Method Method to 25.0 mg/l Cl Reagent Solution

Mercuric Thiocyanate Method Method to 25.0 mg/l Cl Reagent Solution Chloride DOC316.53.01017 Mercuric Thiocyanate Method Method 8113 0.1 to 25.0 mg/l Cl Reagent Solution Scope and application: For water and wastewater. Test preparation Instrument-specific information Table

More information

Chlorine, Free and Total, High Range

Chlorine, Free and Total, High Range Chlorine, Free and Total, High Range DOC316.53.01449 USEPA DPD Method 1 Method DPD 0.1 to 8.0 mg/l Cl 2 Powder Pillows Scope and application: For testing residual chlorine and chloramines in water, wastewater,

More information

Ohio EPA Total (Extracellular and Intracellular) Microcystins - ADDA by ELISA Analytical Methodology Ohio EPA DES Version 2.

Ohio EPA Total (Extracellular and Intracellular) Microcystins - ADDA by ELISA Analytical Methodology Ohio EPA DES Version 2. Ohio EPA Total (Extracellular and Intracellular) Microcystins - ADDA by ELISA Analytical Methodology Ohio EPA DES 701.0 Version 2.3 July 2018 1. SCOPE AND APPLICATION This method is used for the determination

More information

Cyanide, colorimetric, pyridine-pyrazolone

Cyanide, colorimetric, pyridine-pyrazolone Cyanide, colorimetric, pyridine-pyrazolone Parameters and Codes: Cyanide, dissolved, I-1300-85 mg/l as CN): 00723 Cyanide, total, I-3300-85 (mgll as CN): 00720 Cyanide, total-in-bottom-material, dry wt,

More information

SECTION D.2 AMMONIA NITROGEN

SECTION D.2 AMMONIA NITROGEN SECTION D.2 AMMONIA NITROGEN CEDR Method Code: NH4F L01 a) Scope and Application i) This method describes the determination of low-level ammonia nitrogen concentrations in filtered samples taken from fresh

More information

Analysis of Hypochlorite in Bleach

Analysis of Hypochlorite in Bleach Experiment 8 Analysis of Hypochlorite in Bleach Adapted by B. D. West and S. E. Schullery of Eastern Michigan University from ANAL 119, written by Enno Wolthuis, Calvin College, published by Chemical Education

More information

Extraction of Water Samples by Separatory Funnel

Extraction of Water Samples by Separatory Funnel Title: Extraction of Water Samples by Separatory Funnel 3510 Page 1 of 11 Extraction of Water Samples by Separatory Funnel References: EPA 3510C, SW-846, Test Methods for Evaluating Solid Waste: Physical/Chemical

More information

PURPOSE: To determine the Rate Law for the following chemical reaction:

PURPOSE: To determine the Rate Law for the following chemical reaction: PURPOSE: To determine the Rate Law for the following chemical reaction: H 2 O 2 (aq) + 2 I - (aq) + 2 H 3 O + (aq) 4 H 2 O(l) + I 2 (aq) Hydrogen Iodide Hydronium Water Iodine Peroxide Ion Ion PRINCIPLES:

More information

Timberline Ammonia-001. Determination of Inorganic Ammonia by Continuous Flow Gas Diffusion and Conductivity Cell Analysis

Timberline Ammonia-001. Determination of Inorganic Ammonia by Continuous Flow Gas Diffusion and Conductivity Cell Analysis Timberline Ammonia-001 Determination of Inorganic Ammonia by Continuous Flow Gas Diffusion and Conductivity Cell Analysis Prepared By: Dr. Edward F. Askew Date: June 24, 2011 Table of Contents 1. SCOPE

More information

Nitrate plus Nitrite and Nitrite in Seawater by Segmented Flow Analysis (SFA)

Nitrate plus Nitrite and Nitrite in Seawater by Segmented Flow Analysis (SFA) Methodology Nitrate plus Nitrite and Nitrite in Seawater by Segmented Flow Analysis (SFA) (Cartridge Part #A002603) 1.0 Scope and Application 1.1 This method is used to determine the concentration of nitrate

More information

Chloramine (Mono) and Nitrogen, Free Ammonia

Chloramine (Mono) and Nitrogen, Free Ammonia Chloramine (Mono) and Nitrogen, Free Ammonia DOC316.53.01016 Indophenol Method 1 Method 10200 0.04 to 4.50 mg/l Cl 2 0.01 to 0.50 mg/l NH 3 N Powder Pillows Scope and application: For the determination

More information

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR The fill line is to the right.

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR The fill line is to the right. Aluminum DOC316.53.01003 Eriochrome Cyanine R Method 1 Method 8326 0.006 to 0.250 mg/l Al 3+ Powder Pillows Scope and application: For water. 1 Adapted from Standard Methods for the Examination of Water

More information

Ascorbic Acid Titration of Vitamin C Tablets

Ascorbic Acid Titration of Vitamin C Tablets Ascorbic Acid Titration of Vitamin C Tablets Introduction This experiment illustrates how titration, the process of slowly adding one solution to another until the reaction between the two is complete,

More information

DR/4000 PROCEDURE LEAD. 2. The display will show: 3. Fill a 250-mL graduated cylinder to the 250-mL mark with sample.

DR/4000 PROCEDURE LEAD. 2. The display will show: 3. Fill a 250-mL graduated cylinder to the 250-mL mark with sample. Method 8033 DR/4000 PROCEDURE Dithizone Method* (0 to 300 µg/l) Scope and Application: For water and wastewater; USEPA accepted for reporting for wastewater analysis (digestion is required).** See Section

More information

Solubility Product Constant (K sp ) and the Common-Ion Effect for Calcium Iodate, a Salt of Limited Solubility

Solubility Product Constant (K sp ) and the Common-Ion Effect for Calcium Iodate, a Salt of Limited Solubility Solubility Product Constant (K sp ) and the Common-Ion Effect for Calcium Iodate, a Salt of Limited Solubility Purpose Determine the solubility product constant (K sp ) for a sparingly soluble salt. Study

More information

METHOD 9012B TOTAL AND AMENABLE CYANIDE (AUTOMATED COLORIMETRIC, WITH OFF-LINE DISTILLATION)

METHOD 9012B TOTAL AND AMENABLE CYANIDE (AUTOMATED COLORIMETRIC, WITH OFF-LINE DISTILLATION) METHOD 9012B TOTAL AND AMENABLE CYANIDE (AUTOMATED COLORIMETRIC, WITH OFF-LINE DISTILLATION) 1.0 SCOPE AND APPLICATION 1.1 This method is used to determine the concentration of inorganic cyanide (CAS Registry

More information

Alkalinity, USEPA by Flow Injection Analysis (FIA)

Alkalinity, USEPA by Flow Injection Analysis (FIA) Methodology Alkalinity, USEPA by Flow Injection Analysis (FIA) (Cartridge Part #A002745) 1.0 Scope and Application 1.1 This method is used for the determination of alkalinity in drinking water, surface

More information

Safety Note: Safety glasses and laboratory coats are required when performing this experiment

Safety Note: Safety glasses and laboratory coats are required when performing this experiment The Determination of Hypochlorite in Bleach Reading assignment: Burdge, Chemistry 4 th edition, section 4.6. We will study an example of a redox titration in order to determine the concentration of sodium

More information

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID) Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID) Table of Contents Section 1: Summary of Method Section 2: Scope and Application Section

More information

Quaternary Ammonium Compounds

Quaternary Ammonium Compounds , 8337 Quaternary Ammonium Compounds DOC316.53.01128 Direct Binary Complex Method Method 8337 0.2 to 5.0 mg/l as CTAB Powder Pillows Scope and Application: For cooling tower water and pool/spa water Test

More information

Name Period Date. Lab 9: Analysis of Commercial Bleach

Name Period Date. Lab 9: Analysis of Commercial Bleach Name Period Date Lab 9: Analysis of Commercial Bleach Introduction Many common products are effective because they contain oxidizing agents. Some products, which contain oxidizing agents, are bleaches,

More information

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY 1.0 SCOPE AND APPLICATION 1.1 Method 8030 is used to determine the concentration of the following volatile organic compounds: Compound Name

More information

METHOD 9034 TITRIMETRIC PROCEDURE FOR ACID-SOLUBLE AND ACID INSOLUBLE SULFIDES

METHOD 9034 TITRIMETRIC PROCEDURE FOR ACID-SOLUBLE AND ACID INSOLUBLE SULFIDES METHOD 9034 TITRIMETRIC PROCEDURE FOR ACID-SOLUBLE AND ACID INSOLUBLE SULFIDES 1.0 SCOPE AND APPLICATION 1.1 This procedure may be used as a determinative step for acid-soluble and acidinsoluble sulfides

More information

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC) METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC) 1.0 SCOPE AND APPLICATION 1.1 Method 7196 is used to determine the concentration of dissolved hexavalent chromium [Cr(VI)] in EP/TCLP characteristic extracts

More information

Cyanide, Total or Weak Acid Dissociable, by Manual Distillation - PBM

Cyanide, Total or Weak Acid Dissociable, by Manual Distillation - PBM Inorganics Revision Date: March 8, 2017 (Draft) Cyanide, Total or Weak Acid Dissociable, by Manual Distillation - PBM Parameter Analytical Method Introduction Method Summary MDL(s) and EMS Analyte Codes

More information

METHOD 3520C CONTINUOUS LIQUID-LIQUID EXTRACTION

METHOD 3520C CONTINUOUS LIQUID-LIQUID EXTRACTION METHOD 3520C CONTINUOUS LIQUID-LIQUID EXTRACTION 1.0 SCOPE AND APPLICATION 1.1 This method describes a procedure for isolating organic compounds from aqueous samples. The method also describes concentration

More information

Ascorbic Acid Titration of Vitamin C Tablets

Ascorbic Acid Titration of Vitamin C Tablets Ascorbic Acid Titration of Vitamin C Tablets Introduction This experiment illustrates how titration, the process of slowly adding one solution to another until the reaction between the two is complete,

More information

Method for estimation of iodine in urine

Method for estimation of iodine in urine Method for estimation of iodine in urine Described herewith is the standard operating procedure for estimation of iodine in urine by colorimetric method after chloric acid digestion A) Principle: Urine

More information

$ % K st. K D [ I 2 ] Aqueous. [ I 2 ] Hexane. % Aqueous

$ % K st. K D [ I 2 ] Aqueous. [ I 2 ] Hexane. % Aqueous Determination of the Stability Constant of the Tri- Iodide Ion by Solvent Extraction Introduction Molecular iodine reacts with iodide to form a complex, called the tri- iodide ion, according to the reaction:

More information

Test Method: CPSC-CH-E

Test Method: CPSC-CH-E UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 10901 DARNESTOWN RD GAITHERSBURG, MD 20878 Test Method: CPSC-CH-E1001-08 Standard Operating Procedure

More information

Microscale Solvent Extraction (MSE)

Microscale Solvent Extraction (MSE) Title: Microscale Solvent Extraction (MSE) 3570 Page 1 of 11 Microscale Solvent Extraction (MSE) References: EPA Method 3570, Test Methods for Evaluating Solid Waste, SW-846, November 2002, Revision 0,

More information

Powder Pillows 0.01 to 1.60 mg/l SiO 2 (LR, colorimeters)

Powder Pillows 0.01 to 1.60 mg/l SiO 2 (LR, colorimeters) Silica DOC316.53.01132 Heteropoly Blue Method 1 Method 8186 0.010 to 1.600 mg/l SiO 2 (LR, spectrophotometers) Powder Pillows 0.01 to 1.60 mg/l SiO 2 (LR, colorimeters) Scope and application: For boiler

More information

Total Kjeldahl Nitrogen by Gas Diffusion and Flow Injection Analysis (FIA)

Total Kjeldahl Nitrogen by Gas Diffusion and Flow Injection Analysis (FIA) Methodology Total Kjeldahl Nitrogen by Gas Diffusion and Flow Injection Analysis (FIA) (Cartridge Part #A002380) 1.0 Scope and Application 1.1 This method is used for the determination of Total Kjeldahl

More information

Chlorphosphonazo Colorimetric Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Solution Pillow. Instrument Adapter Sample cell

Chlorphosphonazo Colorimetric Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Solution Pillow. Instrument Adapter Sample cell Hardness DOC316.53.01044 Chlorphosphonazo Colorimetric Method Method 8374 8 to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Solution Pillow Scope and application: For boiler and ultrapure water. Test preparation

More information

METHOD DETERMINATION OF SULFATE BY AUTOMATED COLORIMETRY. Edited by James W. O'Dell Inorganic Chemistry Branch Chemistry Research Division

METHOD DETERMINATION OF SULFATE BY AUTOMATED COLORIMETRY. Edited by James W. O'Dell Inorganic Chemistry Branch Chemistry Research Division METHOD 375.2 DETERMINATION OF SULFATE BY AUTOMATED COLORIMETRY Edited by James W. O'Dell Inorganic Chemistry Branch Chemistry Research Division Revision 2.0 August 1993 ENVIRONMENTAL MONITORING SYSTEMS

More information

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction II. Quality Control A. Introduction ENCO adheres to strict quality control practices in order to assure our clients that the data provided are accurate and reliable. We are required by the EPA to analyze

More information

DR/4000 PROCEDURE MERCURY. Phase 1: Sample Digestion must be done in a fume hood! Toxic gases may be produced.

DR/4000 PROCEDURE MERCURY. Phase 1: Sample Digestion must be done in a fume hood! Toxic gases may be produced. Method 10065 DR/4000 PROCEDURE Scope and Application: For water, wastewater and seawater. * Adapted from Analytical Chemistry, 25 (9) 1363 (1953) Cold Vapor Mercury Preconcentration Method* (0.1 to 2.5

More information

Chem 2115 Experiment #7. Volumetric Analysis & Consumer Chemistry Standardization of an unknown solution, analysis of vinegar & antacid tablets

Chem 2115 Experiment #7. Volumetric Analysis & Consumer Chemistry Standardization of an unknown solution, analysis of vinegar & antacid tablets Chem 2115 Experiment #7 Volumetric Analysis & Consumer Chemistry Standardization of an unknown solution, analysis of vinegar & antacid tablets OBJECTIVE: The goals of this experiment are to learn titration

More information