Application Note TABLE OF CONTENTS

Size: px
Start display at page:

Download "Application Note TABLE OF CONTENTS"

Transcription

1 Application Note 25 Making optical density measurements automatically corrected to a 1 cm pathlength in the SPECTRAmax PLUS microplate spectrophotometer (The three P s of Pathcheck : Principle, Procedures and Precautions) TABLE OF CONTENTS INTRODUCTION PRINCIPLES OF PATHCHECK Pathlength correction using near infra-red measurements The pre-installed Water Constant: a shortcut PATHLENGTH CORRECTION BY THE SPECTRAmax PLUS Two ways to correct pathlength Why must the plate be pre-read? USING PATHCHECK Getting ready Materials Set up SOFTmax PRO to use PathCheck Pre-read the microplate Pathlength correction using a cuvette reference Pathlength correction using the Water Constant Using PathCheck to inspect a microplate for pipetting errors EXPERIMENTAL RESULTS Experimental design and cuvette results Plate optical densities displayed without pathlength correction Plate optical densities displayed with pathlength correction Plate data displayed as absolute pathlength in centimeters The three data presentations combined into a single graph DISCUSSION Advice and precautions Evaporation Failure to subtract appropriate pre-read values Potential interference

2 INTRODUCTION UV/VIS spectrophotometers and microplate readers differ fundamentally in their beam geometry. In spectrophotometers, samples are read through cuvettes or tubes with a horizontal (cross-sectional) light path. The horizontal light beam and the customary 1 cm pathlength make assays based on extinction coefficients straightforward and allow easy comparison of results between labs. In microplate readers, the vertical light beam results in a pathlength that depends on the volume of fluid in each well. The variable pathlength in microplates has made it difficult to perform extinctionbased assays and confusing to compare results obtained in a microplate reader with those obtained in a spectrophotometer. This problem has been remedied by the introduction of the SPECTRAmax PLUS microplate spectrophotometer and its PathCheck feature, the ability to determine the pathlength in each well of a microplate and automatically normalize the absorbance value to a 1 cm pathlength. This application note discusses the principles on which PathCheck is based, and gives specific instructions for using it with a SPECTRAmax PLUS microplate spectrophotometer and SOFTmax PRO 2.0 software. PRINCIPLES OF PATHCHECK Pathlength correction using near infra-red measurements Water is essentially transparent from 200 nm to 900 nm, but in the near infrared (NIR), it has a distinctive absorption peak near 977 nm (Figure 1). This characteristic absorbance band in a spectral region where most biological molecules have little or no absorbance can be utilized to measure the pathlength of light through an aqueous sample Absorbance Wavelength (nm) Figure 1: Absorbance of water Lambert s law of light absorption predicts absorbance is proportional to the distance that light travels through the sample: the longer the pathlength, the higher the absorbance peak. Baseline absorbance can be measured at a wavelength distant from the water peak, e.g. 900 nm. The pathlength of light 2

3 through an aqueous sample can be calculated by comparing the peak height obtained in a microplate well with the peak height obtained in a standard 1 cm cuvette: ( A 977 A 900 ) sample ( = A 977 A 900 ) Pathlength of aqueous sample 1.0 cm aqueous solvent In practice, 977 nm is not an ideal wavelength for pathlength measurements because at that wavelength the absorption of water is temperature-dependent. Pathlength measurements are subject to error if the microplate and cuvette measurements are not made at exactly the same temperature. SPECTRAmax PLUS avoids temperature-dependency by measuring water absorbance at 1000 nm, near a temperature isosbestic point. The trade-off is an increased requirement for the instrument to have superior wavelength reproducibility, because the measurement is made on a slope of the absorbance curve, rather than at the absorbance maximum. Using the ratio in the equation above, the absorbance of the aqueous sample in a microplate well (in the example below, protein at 280 nm) can be corrected to a 1 cm pathlength as follows: ( A 280 ) ( A sample 1000 A 900 ) cm aqueous solvent = ( A 1000 A 900 ) A 280 sample corrected to 1.0 cm sample The pre-installed Water Constant: a shortcut Because comparatively few substances absorb in the NIR, the quantity (A 1000 A 900 ) 1.0 cm aqueous solvent in the equation above is, for aqueous solutions, practically a constant, and is referred to as the Water Constant. The value of the Water Constant for each SPECTRAmax PLUS is determined during instrument manufacture and is pre-installed into the instrument s firmware. Substituting the Water Constant for (A 1000 A 900 ) 1.0 cm aqueous solvent in the equation for correcting absorbance values in the UV/VIS region then yields: ( A 280 ) Water Constant sample = ( A 1000 A 900 ) A 280 sample corrected to 1.0 cm sample PATHLENGTH CORRECTION BY THE SPECTRAMAX PLUS Two ways to correct pathlength The SPECTRAmax PLUS gives you two options when making pathlength-corrected measurements: 1) putting the aqueous solvent into a clean 1 cm reference cuvette in the instrument s cuvette port and having the instrument base the calculations on the A 1000 and A 900 of the cuvette, or 2) using the Water Constant. the first option is strongly recommended because it ensures the highest possible accuracy and will accommodate a variety of sample solvents. Indeed, a cuvette reference is necessary in cases where the sample solvent is greater than 0.5 M in salts or solutes, contains organic solvent or has unusual absorbance in the NIR. Use of the Water Constant should be considered a shortcut and potentially less accurate. 3

4 In addition to reporting absorbance measurements corrected to a 1 cm pathlength, SOFTmax PRO can report the pathlength in each of the 96 wells. This ability is useful to screen a microplate for volume irregularities or to check for pipetting errors. When performing an absorbance read with PathCheck, SOFTmax PRO performs the following sequence of calculations: 1 Subtraction of the plate pre-read values from the normal read values (i.e., subtraction of the plate background in the UV/VIS region). 2 Pathlength correction (using the ratio of the NIR measurements). 3 Subtraction of plate/group blanks (if any). 4 Additional user-specified custom data reduction (if any). Why must the plate be pre-read? The plate pre-read doesn t necessarily correct for well-to-well variability of the microplate. Instead, the purpose is to subtract the absorbance due to the plate material before pathlength correction is applied. The NIR measurements for pathlength correction do not need blanking or pre-reading because the calculation requires the difference between A 1000 and A 900, and the plate background is essentially the same at both wavelengths. However, at the wavelength(s) in the UV/VIS where the analyte is measured, the plate can contribute significantly to the overall absorbance, therefore the absorbance due to the plate must be subtracted before pathlength correction is applied. For accurate pathlength-corrected measurements, the plate must be pre-read with water in the wells. The reason is not because water absorbs (it doesn t), but because the refractive index of light differs at a plate/air interface versus a plate/water interface. If the plates are sufficiently transparent at the wavelength(s) of interest and have low well-to-well variability, the pre-read doesn t have to be made on the same plate the samples will be read in; another clean plate from the same lot will be adequate. Even more convenient, a single plate can be pre-read, then the pre-read data stored for subsequent use. On the other hand, if the plates are inherently variable at the wavelength(s) of interest, it may be necessary to use the same plate for pre-reading and reading samples, so that adequate well-by-well correction is achieved. USING PATHCHECK Getting ready Materials 1 SPECTRAmax PLUS microplate spectrophotometer 2 High-quality microplates; e.g.: SPECTRAplate Quartz, suitable for all wavelengths, Molecular Devices Corp. (catalog # R8024) SPECTRAplate Quartz half-area microplate, suitable for all wavelengths, Molecular Devices Corp. (catalog # R8028) Quartz microtest 8-well strip, suitable for all wavelengths, Hellma (catalog # QS); use with a frame for 8-well strips, E & K Scientific Products (catalog # ) Note: the 8-well strip frame sold by Evergreen Scientific does not fit 4

5 properly. Disposable UV Plate, suitable for wavelengths > 220 nm (pre-read on same plate recommended below 250 nm), Corning Costar Corp. (catalog # 3635) Nunc flatbottom plates, suitable for wavelengths > 320 nm (pre-read on same plate recommended below 350 nm), Fisher Scientific (catalog # ) Greiner flatbottom plates, suitable for wavelengths > 400 nm (340 nm to 400 nm with same-plate pre-read), E & K Scientific Products (catalog # ) 3 Pipettor and tips or transfer pipets suitable for use with microplates 4 Samples ( µl each) Set up SOFTmax PRO to use PathCheck Step 1 Step 2 Launch SOFTmax PRO, then open a Plate Section or, if necessary, create a new Plate Section. Set up the Instrument Settings dialog box as shown in Figure 2. Select to perform an endpoint read at the desired wavelength(s). Click the Path- Check box to mark it, (pre-read plate will automatically be checked) then click the Cuvette Reference or Water Constant button, depending upon which you wish to use. Automix is not advised because it provides no benefit in this measurement. If you wish to read only part of the plate, click the Strips button and select the strips (columns) to be read. Figure 2: The Instrument Settings dialog box, set up for measurements incorporating PathCheck Step 3 Step 4 Use the Template Editor to create a template showing where standards and unknowns will be located on the microplate. Click the Reduction button in the toolbar to display the Reduction dialog box (Figure 3). Set the wavelength combination (for example, to L1 for single wavelength reads) and the data mode to Absorbance. Click in 5

6 the Apply Pathcheck checkbox to select it, upon which SOFTmax PRO will automatically select Use pre-read plate. Figure 3: The Reduction dialog box, set up for applying a pre-read and PathCheck Pre-read the microplate Step 1 Inspect a clean microplate by holding it up to the light and looking for dust. If needed, blow clean air into and across it, to remove dust particles. Note: For highest accuracy it is important that the plate be dust-free, because dust particles can interfere with the pre-read. Step 2 Step 3 Step 4 Step 5 Pipet distilled water into each well. (The volumes should be about the same as the subsequent sample volumes though accurate pipetting is not necessary.) Put the plate in the SPECTRAmax PLUS drawer, then click the Read button in the Plate section s Status Bar. A dialog box will appear, requesting you to confirm that the read is a pre-read. Click the OK button. After the pre-read is complete, remove the plate from the drawer, pour out the water and blot it dry. If you are planning to use the pre-read data for more than one plate, save an extra copy of the data file containing the pre-read values. Quartz plates are so uniform that you do not need to subtract the plate background on a well-by-well basis. You can use different plates for the pre-reads and sample reads. Better still, you can pre-read once and store the pre-read file for subsequent re-use, being careful to use the Save As command to save the file with a different name each time you use it, to avoid over-writing the original file. Nunc flat-bottom plates are also sufficiently uniform that stored preread values can be used above 380 nm. Between 320 and 380 nm, it is advisable to use the same plate for pre-reads and sample reads. If using Costar UV plates, you may or may not choose to use stored preread values obtained from a plate from the same lot, depending on the precision you require. Costar plates have approximately.050 OD with approximately.007 OD spread at 280 nm. If the raw absorbance in a given well is 1.0, the potential error due plate background variation is less than 1%. But if the raw absorbance is 0.1, the maximum potential error in a given well approaches 10%. Between 220 nm and 250 nm, it is advisable to use the same plate for pre-reads and sample reads. 6

7 Pathlength correction using a cuvette reference If you are using stored pre-read values (see above), open the data file containing the pre-read data you want to use, then skip Steps 1 & 2 below. Step 1 Step 2 Step 3 Step 4 Step 5 Set up SOFTmax PRO to use PathCheck as detailed in "Set up SOFTmax PRO to use PathCheck" on page 5. Select Read Cuvette Reference in the Instrument Settings dialog box. Pre-read an appropriate microplate, following the instructions above. Place a clean quartz or glass cuvette containing distilled water or your aqueous sample solvent in the SPECTRAmax PLUS cuvette port. Plastic cuvettes are also generally acceptable, but the performance of a particular cuvette should be verified before use in an assay. Take the pre-read microplate (or another microplate from the same high quality lot) and transfer aliquots of your samples and blanks into their designated wells. Accurate pipetting is not necessary though the volumes should be between 100 µl and 300 µl for best pathlength-corrected results. Put the plate in the SPECTRAmax PLUS drawer, then click the Read button in the Plate section s Status Bar. A dialog box will appear, requesting you to confirm that the read is a normal read. Click the OK button. The cuvette will be read at the same time the plate is read, and its NIR absorbance values used in the PathCheck calculations. Note:To avoid errors due to evaporation, make the readings within a few minutes of putting the samples in the microplate. If the read must be delayed, cover the plate with an adhesive seal. Remove the seal immediately prior to reading the plate. Pathlength correction using the Water Constant Step 1 Set up SOFTmax PRO to use PathCheck as detailed in "Set up SOFTmax PRO to use PathCheck" on page 5. Select Water Constant in the Instrument Settings dialog box (Figure 4). Figure 4: The Instrument Settings dialog box, set up to use PathCheck with the Water Constant Step 2 Pre-read an appropriate microplate, following the instructions above. 7

8 Step 3 Step 4 Take the pre-read microplate (or another microplate from the same high quality lot) and transfer aliquots of your samples and blanks into their designated wells. Accurate pipetting is not necessary, though the volumes should be between 100 µl and 300 µl for best pathlength-corrected results. Put the plate in the SPECTRAmax PLUS drawer. Click the Read button in the Plate section s Status Bar. A dialog box will appear, requesting you to confirm that the read is a normal read. Click the OK button. Note:To avoid errors due to evaporation, make the readings within a few minutes of putting the samples in the microplate. If the read must be delayed, cover the plate with an adhesive seal. Remove the seal immediately prior to reading the plate. Using PathCheck to inspect a microplate for pipetting errors Step 1 Step 2 Using SOFTmax PRO, select a Plate Section or, if necessary, create a new Plate by selecting New Plate from the Experiment menu. Set up the Instrument Settings dialog box as shown in Figure 5. Select to perform an end-point read at any wavelength. Note: SOFTmax PRO requires that you enter a UV/VIS wavelength at which to read, even though that measurement is not used in calculating pathlength Select PathCheck with a cuvette reference (or use the Water Constant, if desired) and de-select pre-read plate. (Pre-reading is unnecessary because the UV/VIS measurement is not used in calculating pathlength.) Figure 5: The Instrument Settings dialog box, set up to check pipetting accuracy with PathCheck Step 3 Click the Reduction button in the Plate Section s tool bar to display the Reduction dialog box (Figure 6). Select Custom from the Wavelength Combination pop-up menu, then click the formula button to display the Calculation dialog box. Type!Pathlength in the formula field of the 8

9 dialog box (do not include the quote marks, and do not put a space between the! and Pathlength). Figure 6: The Reduction dialog box, set up for checking pipetting accuracy with PathCheck Step 4 For quick visualization of the plate it is useful to display the data in grayscale. Click the Display button in the Plate section s toolbar to produce the Display dialog box (Figure 7), then click the Grayscale button. If desired, you can also select to have the reduced number displayed in each well. Figure 7: The Display dialog box, set to display data in grayscale Step 5 Put the plate into the of SPECTRAmax PLUS drawer, then click the Read button in the Plate Status Bar. EXPERIMENTAL RESULTS Experimental design and cuvette results A yellow buffer solution (Fisher certified buffer, ph 7.00) was used to illustrate the performance of SPECTRAmax PLUS and PathCheck. The buffer has an absorbance maximum at 426 nm and its absorbance at that wavelength was first measured in a standard 1 cm cuvette. The buffer was then pipetted into wells of a Nunc flat-bottomed microplate in volumes of 75 to 300 µl, and the absorbance was measured, using PathCheck to normalize it to a 1 cm pathlength. Note: 75 µl is less than the recommended minimum volume per well, but was included to illustrate the variability occurring at marginal volumes. 9

10 A Cuvette Set was created and in the Cuvette Set Template dialog box, a group called Cuvette was created, comprising 3 samples named Yellow Buffer (Figure 8). Figure 8: The Template Editor for a Cuvette Section In the Instrument Setup dialog box for the Cuvette Set, an endpoint read at 426 nm was specified. A glass cuvette was filled with deionized water and placed in the SPECTRAmax PLUS cuvette port. The REF button in the status bar was clicked to perform a reference read on the cuvette. The cuvette was then replaced with a matched cuvette containing the yellow buffer, and the absorbance of the yellow buffer was read three times. Figure 9 shows the resulting absorbance values in the Cuvette Set and in the Group Table. The results indicate that the absorbance of the yellow buffer at 426 nm in a standard 1 cm cuvette was Figure 9: The Cuvette set for Fisher yellow buffer, and the corresponding Group Table 10

11 A Nunc flat-bottom microplate was pre-read, then the buffer was pipetted into a second microplate from the same lot, in the volumes specified in the template (Figure 10). The cuvette was left in the cuvette port and the plate was read using the cuvette as a reference. Figure 10: Template showing the location of the sample volumes on the microplate Plate optical densities displayed without pathlength correction Figure 11 displays the results when PathCheck is de-selected in the Reduction dialog box. The plate section is displayed in grayscale for easy visualization. As one would predict, without pathlength correction, the absorbance values increase with increasing volume of sample in the microplate wells. The Group Table indicates that the mean values range from 0.09 for the 75 µl group to for the 300 µl group. Figure 11: Plate Section and Group Table showing plate data with PathCheck deselected 11

12 Plate optical densities displayed with pathlength correction Figure 12 shows the same set of data with PathCheck applied to it. For all the sample volumes, the corrected values are close to the cuvette value. The column Wells/Cuvette in the Group Table gives the mean corrected OD 426 divided by the value obtained in the cuvette (0.386). The mean values are all within 1% of the cuvette value. The considerably greater variability in the wells containing only 75 µl is obvious in the grayscale representation. Even though the latter group was still within 1% of the cuvette value in this carefully controlled experiment, we recommend that PathCheck be applied only to wells containing at least 100 µl. Figure 12: Plate Section and Group Table showing plate data with PathCheck applied 12

13 Plate data displayed as absolute pathlength in centimeters Figure 13 shows the same data set displayed in absolute pathlength. Not surprisingly, the grayscale representation of the data looks similar to that in Figure 11, which displays the raw OD 426 values. The Group Table indicates that the mean pathlength values ranged from cm to cm. Figure 13: Plate Section and Group Table showing mean pathlength in centimeters The three data presentations combined into a single graph In Figure 12, absorbance at 426 nm with and without pathlength correction is plotted as a function of pathlength in centimeters. As expected, the uncorrected absorbance values increase with increasing pathlength (i.e., with increasing volume in the wells). When PathCheck is applied, the corrected absorbance values are almost identical. Figure 14: OD 426 with and without pathlength correction 13

14 DISCUSSION Advice and precautions When pathlength-corrected measurements are made using an appropriate procedure, the values should be within 2.5% or better of values obtained from the same solution in a 1 cm cuvette. Two potential causes of erroneous results are evaporation and failure to subtract pre-read values. Evaporation Recall the equation for pathlength correction: ( A 280 ) ( A sample 1000 A 900 ) cm aqueous solvent = ( A 1000 A 900 ) A 280 sample corrected to 1.0 cm sample If evaporation occurs, the value for (A A 900 ) sample in the denominator decreases, causing a progressive overcorrection. (The reading in the UV/VIS region does not change unless the analyte happens to be volatile.) The effect is particularly noticeable in wells with small volumes. Even if the wells contain 300 µl of solution, the effect of evaporation is noticeable within 15 min (~1% error). To avoid errors due to evaporation, take the readings within minutes of putting the samples in the microplate. If the read must be delayed, cover the plate with an adhesive seal, then remove the seal immediately before reading the plate. Failure to subtract appropriate pre-read values When using PathCheck to correct for pathlength through a sample, SOFTmax PRO goes through the following sequence of calculations: 1 Subtraction of the plate pre-read values from the normal read values (i.e., the readings in UV/VIS region). 2 Pathlength correction (using the ratio of the NIR measurements). 3 Subtraction of plate/group blanks (if any). 4 Additional user-specified custom data reduction (if any). The purpose of the pre-read is not necessarily to correct for well-to-well variability in the microplate, but instead to subtract the absorbance due to the plate material before pathlength correction is applied. The plate should be preread with water in the wells. Wells pre-read with water generally have less absorbance than dry wells. (e.g., at 426 nm Nunc microplates give absorbance values of approximately and when read with and without water in the wells.) Thus pre-reading a dry plate results in pathlength-corrected absorbance values that are lower than the cuvette values. If the pre-read step is omitted entirely, the pathlength-corrected results are grossly high. The good news is that pre-reads do not necessarily have to be made with the same plate as the final reads. Some plates are so uniform (2-3 MOD spread overall) that one plate can be pre-read and another clean, dry plate be used for the samples. Even more convenient, pre-read data can be stored in SOFTmax PRO and used over and over again. Also, SOFTmax PRO allows you to copy and paste pre-read data from one plate section to another, provided the instrument settings are identical in the two plate sections. 14

15 Potential interference Pathlength correction is intended for use with aqueous solutions, although small quantities of organic solvents can be tolerated if the PathCheck measurements are made with a cuvette reference. As stated above, a cuvette reference is strongly recommended for pathlength-corrected measurements, although the water constant can often be used as a shortcut. However, if the sample solvent contains a high concentration (e.g. > 0.5 M) of salts or other solutes, or contains organic solvent, the NIR absorbance values may differ from water. In such cases the Water Constant is not appropriate, and it is essential to take pathlength-corrected measurements using a cuvette reference containing the sample solvent. Pathlength correction using NIR absorbance is appropriate as long as there is nothing in the sample that interferes with the measurements. Turbidity is one source of interference. Also, any molecule with differential absorption at 1000 and 900 nm will interfere if present in a high enough concentration. Although few biological substances absorb between 900 and 1000 nm, interference may be expected from some highly-conjugated molecules such as the pthalocyanines, chlorophylls, carotenoids, phycobilins, as well as porphyrin-containing or related molecules such a myoglobin, hemoglobin and peroxidases. Reduced phosphomolybdate complexes also absorb between 900 and 1000 nm. Pathlength correction in such solutions, however, can still be applied if the interfering substances are dilute enough such their NIR absorption is insignificant relative to water. Provided that the interfering species is present at a constant concentration in all samples, the interference also can be eliminated by placing a sample with the interfering species in the reference cuvette. SALES OFFICE United States & Canada Molecular Devices Tel Fax Brazil Molecular Devices Brazil Tel Fax China Molecular Devices Shanghai Tel Fax Germany Molecular Devices GmbH Tel / Fax / Japan Molecular Devices Japan, Osaka Tel Fax Molecular Devices Japan, Tokyo Tel Fax South Korea Molecular Devices Korea, LLC Tel Fax United Kingdom Molecular Devices Ltd. Tel Fax FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES. The trademarks used herein are the property of Molecular Devices, Inc. or their respective owners Molecular Devices, Inc. Printed in U.S.A. 6/10 # B 15

Optical density measurements automatically corrected to a 1-cm pathlength with PathCheck Technology

Optical density measurements automatically corrected to a 1-cm pathlength with PathCheck Technology APPLICATION NOTE Optical density measurements automatically corrected to a 1-cm pathlength with PathCheck Technology Introduction UV/VIS spectrophotometers and microplate readers differ fundamentally in

More information

Microdetermination of phosphorus using the SPECTRAmax PLUS microplate spectrophotometer: choice of microplate, cuvette or test tube assay formats

Microdetermination of phosphorus using the SPECTRAmax PLUS microplate spectrophotometer: choice of microplate, cuvette or test tube assay formats Application Note 24 Microdetermination of phosphorus using the SPECTRAmax PLUS microplate spectrophotometer: choice of microplate, cuvette or test tube assay formats INTRODUCTION Most spectrophotometric

More information

Measurement of L-Malic Acid in Wines Using the SpectraMax Plus 384 Microplate Reader

Measurement of L-Malic Acid in Wines Using the SpectraMax Plus 384 Microplate Reader now part of MDS Analytical Technologies Measurement of L-Malic Acid in Wines Using the SpectraMax Plus 384 Microplate Reader SpectraMax Application Note #18 By Theresa Heredia and Gillian Sutherland from

More information

L-malic acid measurement in wines using the SpectraMax Plus 384 Microplate Reader

L-malic acid measurement in wines using the SpectraMax Plus 384 Microplate Reader APPLICATION NOTE L-malic acid measurement in wines using the SpectraMax Plus 384 Microplate Reader Introduction Analysis of malic acid, residual sugar, volatile acidity and ammonia is very important for

More information

Human anti-deoxyribonuclease B, anti-dnase B ELISA Kit

Human anti-deoxyribonuclease B, anti-dnase B ELISA Kit Human anti-deoxyribonuclease B, anti-dnase B ELISA Kit Catalog No: E0311h 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ

More information

Spectrometer User s Guide

Spectrometer User s Guide Spectrometer User s Guide (Order Codes: V-SPEC, SPRT-VIS, SP-VIS, SP-UV-VIS, ESRT-VIS) The spectrometer is a portable light spectrophotometer, combining a spectrometer and a light source/cuvette holder.

More information

Monkey Kidney injury molecule 1,Kim-1 ELISA Kit

Monkey Kidney injury molecule 1,Kim-1 ELISA Kit Monkey Kidney injury molecule 1,Kim-1 ELISA Kit Catalog No: E0785Mo 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH

More information

Canine Erythropoietin,EPO ELISA Kit

Canine Erythropoietin,EPO ELISA Kit Canine Erythropoietin,EPO ELISA Kit Catalog No: E0028c 96 Tests Operating instructions www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE

More information

Instructor s Advance Preparation

Instructor s Advance Preparation INSTRUCTOR'S MANUAL Instructor s Advance Preparation This protocol is designed for 80 workstations of 4 students. Each group will prepare a set of standards, a blank, and 2 milk samples (can be a blind

More information

Predictor Assay Setup Guide on the BMG LABTECH CLARIOstar Microplate Readers

Predictor Assay Setup Guide on the BMG LABTECH CLARIOstar Microplate Readers Page 1 of 18 Predictor Assay Setup Guide on the BMG LABTECH CLARIOstar Microplate Readers The BMG LABTECH CLARIOstar Microplate Readers were tested for compatibility with Life Technologies' Predictor herg

More information

Human papillomavirus,hpv ELISA Kit

Human papillomavirus,hpv ELISA Kit Human papillomavirus,hpv ELISA Kit Catalog No: E0787h 96 Tests Operating instructions www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE

More information

Canine brain natriuretic peptide,bnp ELISA Kit

Canine brain natriuretic peptide,bnp ELISA Kit Canine brain natriuretic peptide,bnp ELISA Kit Catalog No: E0541c 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH

More information

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III) Chem 1B Saddleback College Dr. White 1 Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III) Objectives To use spectroscopy to relate the absorbance of a colored solution to its concentration. To

More information

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS) Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS) The UV-VIS spectrometer is a portable ultraviolet light and visible light spectrophotometer, combining a spectrometer and a light source/cuvette

More information

Mouse Cholecystokinin (CCK) ELISA Kit

Mouse Cholecystokinin (CCK) ELISA Kit Mouse Cholecystokinin (CCK) ELISA Kit Catalog No. CSB-E08115m (96T) This immunoassay kit allows for the in vitro quantitative determination of mouse CCK concentrations in serum, plasma and other biological

More information

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III) Chem 1B Dr. White 11 Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III) Objectives To use spectroscopy to relate the absorbance of a colored solution to its concentration. To prepare a Beer s

More information

Mouse Glutathione S Transferase Alpha 1 (GSTa1)

Mouse Glutathione S Transferase Alpha 1 (GSTa1) Mouse Glutathione S Transferase Alpha 1 (GSTa1) For the quantitative determination of mouse (GSTa1) in serum, plasma and other biological fluids Cat. No. KT-16414 For Research Use Only. Not for use in

More information

Nucleic Acid Quantitation in Microplates

Nucleic Acid Quantitation in Microplates PHARMACEUTICAL application note Nucleic Acid Quantitation in Microplates HansWilly Mueller, Ph.D. J. Fenton Williams, Ph.D. Introduction Many molecular biology applications require the determination of

More information

Human placenta lactogen (HPL)ELISA Kit. MyBioSource.com. Catalog No. MBS (96T)

Human placenta lactogen (HPL)ELISA Kit. MyBioSource.com. Catalog No. MBS (96T) \ Human placenta lactogen (HPL)ELISA Kit Catalog No. MBS703864 (96T) This immunoassay kit allows for the in vitro quantitative determination of human HPL concentrations in serum, plasma. Expiration date

More information

Porcine Factor-related Apoptosis(FAS) ELISA Kit

Porcine Factor-related Apoptosis(FAS) ELISA Kit Porcine Factor-related Apoptosis(FAS) ELISA Kit Catalog No. CSB-E09369p (96T) This immunoassay kit allows for the in vitro quantitative determination of porcine FAS concentrations in serum, plasma and

More information

Human Mullerian Inhibiting Substance/Anti-Mullerian hormone (MIS/AMH)Elisa Kit

Human Mullerian Inhibiting Substance/Anti-Mullerian hormone (MIS/AMH)Elisa Kit Human Mullerian Inhibiting Substance/Anti-Mullerian hormone (MIS/AMH)Elisa Kit Catalog No. CSB-E12756h (96T) This immunoassay kit allows for the in vitro quantitative determination of human MIS/AMH concentrations

More information

Mouse cross linked N-telopeptide of typeⅠcollagen, NTX ELISA Kit

Mouse cross linked N-telopeptide of typeⅠcollagen, NTX ELISA Kit Mouse cross linked N-telopeptide of typeⅠcollagen, NTX ELISA Kit Catalog No: E0639m 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE

More information

Determining the Concentration of a Solution: Beer s Law

Determining the Concentration of a Solution: Beer s Law Determining the Concentration of a Solution: Beer s Law Vernier Spectrometer 1 The primary objective of this experiment is to determine the concentration of an unknown copper (II) sulfate solution. You

More information

Human Anti-Ovary Antibody (IgG)ELISA Kit

Human Anti-Ovary Antibody (IgG)ELISA Kit Human Anti-Ovary Antibody (IgG)ELISA Kit Catalog No. MBS703636 (96 tests) This immunoassay kit allows for the in vitro semi-quantitative determination of human Anti-Ovary Antibody(IgG) concentrations in

More information

Pig Vascular Endothelial Cell Growth Factor A (VEGF-A) ELISA

Pig Vascular Endothelial Cell Growth Factor A (VEGF-A) ELISA Pig Vascular Endothelial Cell Growth Factor A (VEGF-A) ELISA For the quantitative determination of pig VEGF-A in serum, plasma and other biological fluids. Cat. No. KT-32008 For Research Use Only. Not

More information

Human anti-ige receptor antibody ELISA Kit

Human anti-ige receptor antibody ELISA Kit Human anti-ige receptor antibody ELISA Kit Catalog No. MBS702743 (96 T) This immunoassay kit allows for the in vitro semi-quantitative determination of human anti-ige receptor antibody concentrations in

More information

Human Aspartate aminotransferase, AST ELISA Kit

Human Aspartate aminotransferase, AST ELISA Kit Human Aspartate aminotransferase, AST ELISA Kit Catalog No: E1214h 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH

More information

Z -LYTE Assay Setup Guide on the BMG LABTECH CLARIOstar Reader

Z -LYTE Assay Setup Guide on the BMG LABTECH CLARIOstar Reader 08 Jan 15 Page 1 of 18 Z -LYTE Assay Setup Guide on the BMG LABTECH CLARIOstar Reader The BMG LABTECH CLARIOstar Microplate Readers were tested for compatibility with the Life Technologies Z -LYTE Assay

More information

ab Caspase 3, Caspase 8 and Caspase 9 Multiplex Activity Assay Kit (Fluorometric)

ab Caspase 3, Caspase 8 and Caspase 9 Multiplex Activity Assay Kit (Fluorometric) Version 1 Last updated 6 April 2017 ab219915 Caspase 3, Caspase 8 and Caspase 9 Multiplex Activity Assay Kit (Fluorometric) For monitoring multiple caspase activation in live cells. This product is for

More information

Human von Willebrand Factor cleavingprotease(vwf-cp) ELISA Kit. Catalog No. MBS (96T)

Human von Willebrand Factor cleavingprotease(vwf-cp) ELISA Kit. Catalog No. MBS (96T) Human von Willebrand Factor cleavingprotease(vwf-cp) ELISA Kit Catalog No. MBS705447 (96T) This immunoassay kit allows for the in vitro quantitative determination of human vwf-cp concentrations in serum,

More information

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Operation Manual SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC. 4.18 Foreword

More information

Human anti-gliadin antibody (IgA)ELISA Kit

Human anti-gliadin antibody (IgA)ELISA Kit Human anti-gliadin antibody (IgA)ELISA Kit Catalog No. MBS701727 (96 tests) This immunoassay kit allows for the in vitro semi-quantitative determination of human anti-gliadin antibody(iga) concentrations

More information

Human hepatitis B virus surface antigen(hbsag) ELISA Kit

Human hepatitis B virus surface antigen(hbsag) ELISA Kit Human hepatitis B virus surface antigen(hbsag) ELISA Kit Catalog Number. CSB-E10089h For the qualitative determination of human hepatitis B virus surface antigen (HBsAg) concentrations in serum, plasma.

More information

NanoDrop One Viewer software NanoDrop One Website. NanoDrop One Website NanoDrop One Viewer software NanoDrop One Website Software System Update Update Update Software, Update Note OK Language Measure

More information

Mouse estrogen, E ELISA Kit

Mouse estrogen, E ELISA Kit Mouse estrogen, E ELISA Kit Catalog No: E0696m 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE

More information

Human cross linked N-telopeptide of typeⅠcollagen, NTX ELISA Kit

Human cross linked N-telopeptide of typeⅠcollagen, NTX ELISA Kit Human cross linked N-telopeptide of typeⅠcollagen, NTX ELISA Kit Catalog No: E0639h 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE

More information

Human anti-ganglioside IgG antibody (GM1-IgG) ELISA Kit

Human anti-ganglioside IgG antibody (GM1-IgG) ELISA Kit Human anti-ganglioside IgG antibody (GM1-IgG) ELISA Kit Catalog No. CSB-E09694h (96 tests) This immunoassay kit allows for the in vitro semi-quantitative determination of human GM1-IgG concentrations in

More information

Sheep myeloperoxidase(mpo) ELISA kit

Sheep myeloperoxidase(mpo) ELISA kit Sheep myeloperoxidase(mpo) ELISA kit Catalog No. CSB-EL014757SH (96T) This immunoassay kit allows for the in vitro quantitative determination of sheep MPO concentrations in serum and plasma. Expiration

More information

Human Paraneoplastic pemphigus (PNP)antibody ELISA Kit. Catalog No. MBS (96 T)

Human Paraneoplastic pemphigus (PNP)antibody ELISA Kit. Catalog No. MBS (96 T) Human Paraneoplastic pemphigus (PNP)antibody ELISA Kit Catalog No. MBS704248 (96 T) This immunoassay kit allows for the in vitro quantitative determination of human Paraneoplastic pemphigus(pnp)antibody

More information

Porcine Immunoglobulin E (IgE)ELISA Kit

Porcine Immunoglobulin E (IgE)ELISA Kit Porcine Immunoglobulin E (IgE)ELISA Kit Catalog No. MBS703293 (96T) This immunoassay kit allows for the in vitro quantitative determination of porcine IgE concentrations in serum and plasma,. Expiration

More information

The Plus for your lab!

The Plus for your lab! BioPhotometer plus NEW! analysis system The Plus for your lab! The easy, rapid and reliable BioPhotometer plus analysis system See it clearly! UVette Precision in plastics The patented* 1 UVette is the

More information

Bisphenol A ELISA Kit

Bisphenol A ELISA Kit Bisphenol A ELISA Kit Catalog Number KA1495 96 assays Version: 11 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Principle of the Assay... 3 General

More information

Human vitamin A (VA) ELISA

Human vitamin A (VA) ELISA Human vitamin A (VA) ELISA For the quantitative determination of human VA in serum and plasma Cat. No. KU-113 For Research Use Only. Not for use in diagnostic procedures. Page 1 of 6 Rev. 13335113 INTENDED

More information

Human cyclophilin A, CyPA ELISA Kit

Human cyclophilin A, CyPA ELISA Kit Human cyclophilin A, CyPA ELISA Kit Catalog No: E0979h 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE

More information

Rat Advanced Glycation End Products(AGEs) ELISA Kit

Rat Advanced Glycation End Products(AGEs) ELISA Kit Rat Advanced Glycation End Products(AGEs) ELISA Kit Catalog No. CSB-E09413r (96 T) This immunoassay kit allows for the in vitro quantitative determination of rat AGEs concentrations in serum, plasma and

More information

Human rheumatoid factor (RF) antibody (IgM) ELISA Kit

Human rheumatoid factor (RF) antibody (IgM) ELISA Kit Human rheumatoid factor (RF) antibody (IgM) ELISA Kit Catalog Number. CSB-EQ027654HU For the qualitative determination of human rheumatoid factor (RF) antibody (IgM) concentrations in serum, plasma. This

More information

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013 Absorbance Experiment 13 Dilutions and Data Handling in a Spreadsheet rev 1/2013 GOAL: This lab experiment will provide practice in making dilutions using pipets and introduce basic spreadsheet skills

More information

Acetylcholine (Human) ELISA Kit

Acetylcholine (Human) ELISA Kit Acetylcholine (Human) ELISA Kit Catalog Number KA1167 96 assays Version: 02 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle

More information

Mouse Tri-iodothyronine, T3 ELISA Kit

Mouse Tri-iodothyronine, T3 ELISA Kit Mouse Tri-iodothyronine, T3 ELISA Kit Catalog No: E0453m 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE

More information

Human Papillomavirus Antibody (IgG) ELISA Kit

Human Papillomavirus Antibody (IgG) ELISA Kit Human Papillomavirus Antibody (IgG) ELISA Kit Catalog No. CSB-E08782h (96 tests) This immunoassay kit allows for the in vitro semi-quantitative determination of human papillomavirus antibody(igg) concentrations

More information

Procine GHb ELISA Kit

Procine GHb ELISA Kit Procine GHb ELISA Kit For the quantitative in vitro determination of Procine Glycated hemoglobin concentrations in serum - plasma - celiac fluid - tissue homogenate - body fluid FOR LABORATORY RESEARCH

More information

Human anti-myelin associated glycoprotein antibody (MAG) Ab ELISA Kit

Human anti-myelin associated glycoprotein antibody (MAG) Ab ELISA Kit Human anti-myelin associated glycoprotein antibody (MAG) Ab ELISA Kit Catalog Number. MBS700087 For the qualitative determination of human anti-myelin associated glycoprotein antibody (MAG) concentrations

More information

Human prolactin, PRL ELISA Kit

Human prolactin, PRL ELISA Kit Human prolactin, PRL ELISA Kit Catalog No: E0846h 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE

More information

MEASUREMENT: PART II

MEASUREMENT: PART II 1 MEASUREMENT: PART II Copyright: Department of Chemistry, University of Idaho, Moscow, ID 83844-2343, 2013. INTRODUCTION Read and/or review Section 1.7 and Figure 7.5 in your textbook. The first part

More information

Jasco V-670 absorption spectrometer

Jasco V-670 absorption spectrometer Laser Spectroscopy Labs Jasco V-670 absorption spectrometer Operation instructions 1. Turn ON the power switch on the right side of the spectrophotometer. It takes about 5 minutes for the light source

More information

Human cholecystokinin octapeptide, CCK-8 ELISA Kit

Human cholecystokinin octapeptide, CCK-8 ELISA Kit Human cholecystokinin octapeptide, CCK-8 ELISA Kit Catalog No: E1044h 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH

More information

Mouse cyclooxygenase-2, COX-2 ELISA Kit

Mouse cyclooxygenase-2, COX-2 ELISA Kit Mouse cyclooxygenase-2, COX-2 ELISA Kit Catalog No: E0699m 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE

More information

Pig immunoglobulin E (IgE) ELISA Kit

Pig immunoglobulin E (IgE) ELISA Kit Pig immunoglobulin E (IgE) ELISA Kit Catalog Number. CSB-E06803p For the quantitative determination of pig immunoglobulin E (IgE) concentrations in serum, plasma. This package insert must be read in its

More information

Human 25-hydroxy vitamin D3 (25HVD3) ELISA Kit

Human 25-hydroxy vitamin D3 (25HVD3) ELISA Kit Human 25-hydroxy vitamin D3 (25HVD3) ELISA Kit Catalog Number. CSB-E08097h For the quantitative determination of human 25-hydroxy vitamin D3 (25HVD3) concentrations in serum. This package insert must be

More information

Determining the Concentration of a Solution: Beer s Law

Determining the Concentration of a Solution: Beer s Law Determining the Concentration of a Solution: Beer s Law LabQuest 11 The primary objective of this experiment is to determine the concentration of an unknown nickel (II) sulfate solution. You will be using

More information

Aflatoxin M1 (AFM1) ELISA Kit

Aflatoxin M1 (AFM1) ELISA Kit Aflatoxin M1 (AFM1) ELISA Kit Catalog Number. CSB-EL027236 This immunoassay kit allows for the in vitro quantitative determination of Aflatoxin M1 concentrations in milk, milk power. This package insert

More information

Determination of an Equilibrium Constant

Determination of an Equilibrium Constant Last updated 1/29/2014 - GES Learning Objectives Students will be able to: Determine the numerical value of an equilibrium constant from measured concentrations of all reaction species. Use an absorption

More information

MyBioSource.com. This package insert must be read in its entirety before using this product.

MyBioSource.com. This package insert must be read in its entirety before using this product. Tetracyclines ELISA Kit Catalog Number. MBS940077 This immunoassay kit allows for the in vitro quantitative determination of Tetracyclines concentrations in honey, tissue(chicken, pork). This package insert

More information

MQCA ELISA Test Kit. Catalog No. LSY-10046

MQCA ELISA Test Kit. Catalog No. LSY-10046 MQCA ELISA Test Kit Catalog No. LSY-10046 1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of MQCA in the sample. The coupling antigens are pre-coated on the

More information

Lab 5: Calculating an equilibrium constant

Lab 5: Calculating an equilibrium constant Chemistry 162 The following write-up is inaccurate for the particular chemicals we are using. Please have all sections up through and including the data tables ready before class on Wednesday, February

More information

Human Epinephrine/Adrenaline, EPI ELISA Kit

Human Epinephrine/Adrenaline, EPI ELISA Kit Human Epinephrine/Adrenaline, EPI ELISA Kit Catalog No: E0858h 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE

More information

CTX-II (Human) ELISA Kit

CTX-II (Human) ELISA Kit CTX-II (Human) ELISA Kit Catalog Number KA1225 96 assays Version: 15 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Principle of the Assay... 3 General

More information

Human amyloid beta peptide 1-42, Aβ1-42 ELISA Kit

Human amyloid beta peptide 1-42, Aβ1-42 ELISA Kit Human amyloid beta peptide 1-42, Aβ1-42 ELISA Kit Catalog No: E0946h 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH

More information

Determining the Concentration of a Solution: Beer s Law

Determining the Concentration of a Solution: Beer s Law Determining the Concentration of a Solution: Beer s Law The primary objective of this experiment is to determine the concentration of an unknown cobalt (II) chloride solution. You will use a Vernier SpectroVis

More information

Serotonin (Human) ELISA Kit

Serotonin (Human) ELISA Kit Serotonin (Human) ELISA Kit Catalog Number KA1151 96 assays Version: 02 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Principle of the Assay... 3 General

More information

Human antidiuretic hormone/vasopressin/arginine vasopressin, ADH/VP/AVP ELISA Kit

Human antidiuretic hormone/vasopressin/arginine vasopressin, ADH/VP/AVP ELISA Kit Human antidiuretic hormone/vasopressin/arginine vasopressin, ADH/VP/AVP ELISA Kit Catalog No: E1139h 96 Tests Operating instruction www.eiaab.cn FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC

More information

Additional Materials Required (NOT PROVIDED):

Additional Materials Required (NOT PROVIDED): Protocol VeriKine TM Human Interferon Gamma ELISA Kit Catalog No: 41500 Lot No: 6841 Expiration: December 31, 2018 Assay Range: 12.5-500 pg/ml Store all components at 2 8 C Please review the protocol in

More information

protein interaction analysis bulletin 6300

protein interaction analysis bulletin 6300 protein interaction analysis bulletin 6300 Guide to SPR Data Analysis on the ProteOn XPR36 System Ruben Luo, Bio-Rad Laboratories, Inc., 2000 Alfred Nobel Drive, Hercules, CA 94547 Kinetic Analysis To

More information

Tetracyclines (TCs) ELISA Test Kit

Tetracyclines (TCs) ELISA Test Kit Tetracyclines (TCs) ELISA Test Kit 1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Tetracyclines in the sample. The coupling antigens are pre-coated on the

More information

Human Arachidonic Acid, AA ELISA Kit

Human Arachidonic Acid, AA ELISA Kit Human Arachidonic Acid, AA ELISA Kit Catalog No: E1098h 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE

More information

Human placenta lactogen, HPL ELISA kit

Human placenta lactogen, HPL ELISA kit Human placenta lactogen, HPL ELISA kit Catalog No. E1442h (96 tests) Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE

More information

Biology Unit 2, Structure of Life, Lab Activity 2-2

Biology Unit 2, Structure of Life, Lab Activity 2-2 Biology Unit 2, Structure of Life, Lab Activity 2-2 Photosynthesis is the process by which energy used by living systems is converted from electromagnetic radiation from the sun to chemical energy. This

More information

BIOO FOOD AND FEED SAFETY. Histamine Enzymatic Assay Kit Manual. Catalog #: Reference #:

BIOO FOOD AND FEED SAFETY. Histamine Enzymatic Assay Kit Manual. Catalog #: Reference #: BIOO FOOD AND FEED SAFETY Histamine Enzymatic Assay Kit Manual Catalog #: 1032-05 Reference #: 1032-05 BIOO Scientific Corp. 2010 TABLE OF CONTENTS GENERAL INFORMATION... 1 Product Description... 1 Procedure

More information

Nitrofuran (SEM) ELISA test Kit

Nitrofuran (SEM) ELISA test Kit Nitrofuran (SEM) ELISA test Kit Nitrofuran (SEM) ELISA Test Kit Catalog No. LSY-10004 1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Nitrofuran (SEM) in

More information

Human IL-1 beta ELISA Kit

Human IL-1 beta ELISA Kit For detection and measurement of human interleukin 1 beta Catalog #02004 Catalog #02005 2 Plates 10 Plates Product Description The Human Interleukin 1 beta (IL-1β) ELISA Kit is designed for the quantitative

More information

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1 Determining the Concentration of a Solution: Beer s Law Computer 17 The primary objective of this experiment is to determine the concentration of an unknown copper (II) sulfate solution. You will use a

More information

Human Toll-like receptor 4, TLR4 ELISA Kit

Human Toll-like receptor 4, TLR4 ELISA Kit Human Toll-like receptor 4, TLR4 ELISA Kit Catalog No: E0753h 96 Tests Operating instruction www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE

More information

Cyproheptadine ELISA Test Kit

Cyproheptadine ELISA Test Kit Cyproheptadine ELISA Test Kit Catalog No. LSY-10041 1. Principal This test kit is based on the competitive enzyme immunoassay for the detection of Cyproheptadine in urine, tissue sample. The coupling antigens

More information

Zetasizer Nano-ZS User Instructions

Zetasizer Nano-ZS User Instructions Zetasizer Nano-ZS User Instructions 1. Activate the instrument computer by logging in to CORAL. If needed, log in to the local instrument computer Username: zetasizer. Password: zetasizer. 2. Instrument

More information

ELISA Kit for Plant Gibberellic Acid(GA)

ELISA Kit for Plant Gibberellic Acid(GA) Li StarFish S.r.l. Via Cavour, 35-20063 Cernusco S/N (MI), Italy Tel. +39-02-92150794 - Fax. +39-02-92157285 info@listarfish.it -www.listarfish.it ELISA Kit for Plant Gibberellic Acid(GA) Instruction manual

More information

Human Coagulation Factor X Total Antigen ELISA Kit

Human Coagulation Factor X Total Antigen ELISA Kit Human Coagulation Factor X Total Antigen ELISA Kit Catalog No: IHFXKT-TOT Lot No: SAMPLE INTENDED USE This human coagulation Factor X antigen assay is intended for the quantitative determination of total

More information

Formaldehyde Fluorescent Detection Kit

Formaldehyde Fluorescent Detection Kit K-ASSAY KAMIYA BIOMEDICAL COMPANY KAMIYA BIOMEDICAL COMPANY Formaldehyde Fluorescent Detection Kit For detection in human urine and tissue culture media Cat. No. KT-723 For Research Use Only. Not for Use

More information

FLUORESCENCE APPLICATIONS

FLUORESCENCE APPLICATIONS FLUORESCENCE APPLICATIONS CORRECTION OF EMISSION SPECTRA USING THE PERKINELMER MODEL LS-50 LUMINESCENCE SPECTROMETER Spectra collected on luminescence spectrometers consist of true spectral information

More information

Human Syndecan-3 ELISA Kit

Human Syndecan-3 ELISA Kit BioAim Scientific Inc Human Syndecan-3 ELISA Kit Cat.No: 3010574 Instruction Manual (Last revised May 01, 2017) For research use only TABLE OF CONTENTS I. INTRODUCTION.......3 II. MATERIALS SUPPLIED 4

More information

Predictor Assay Setup Guide on the Tecan Safire 2 Microplate Reader

Predictor Assay Setup Guide on the Tecan Safire 2 Microplate Reader Page 1 of 16 Predictor Assay Setup Guide on the Tecan Safire 2 Microplate Reader NOTE: The Tecan Safire 2 Microplate Reader was tested for compatibility with Invitrogen's Predictor herg FP Assay (PV5365)

More information

This immunoassay kit allows for the in vitro quantitative determination of Aflatoxin M1 concentrations in milk, milk power.

This immunoassay kit allows for the in vitro quantitative determination of Aflatoxin M1 concentrations in milk, milk power. Aflatoxin M1 (AFM1) ELISA Kit This immunoassay kit allows for the in vitro quantitative determination of Aflatoxin M1 concentrations in milk, milk power. This package insert must be read in its entirety

More information

Malachite Green Phosphate Detection Kit Catalog Number: DY996

Malachite Green Phosphate Detection Kit Catalog Number: DY996 Malachite Green Phosphate Detection Kit Catalog Number: DY996 This Malachite Green Phosphate Detection Kit employs a simple, sensitive, reproducible, and non-radioactive method for measuring inorganic

More information

CA125 (Human) ELISA Kit

CA125 (Human) ELISA Kit CA125 (Human) ELISA Kit Catalog Number KA0205 96 assays Version: 03 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Principle of the Assay... 3 General

More information

Kinetics of Crystal Violet Bleaching

Kinetics of Crystal Violet Bleaching Kinetics of Crystal Violet Bleaching Authors: V. C. Dew and J. M. McCormick* From Update March 12, 2013 with revisions Nov. 29, 2016 Introduction Chemists are always interested in whether a chemical reaction

More information

ab83360 Ammonia Assay Kit

ab83360 Ammonia Assay Kit Version 8 Last updated 18 December 2017 ab83360 Ammonia Assay Kit For the measurement of total ammonia and ammonium levels in various samples This product is for research use only and is not intended for

More information

Instrumental Technique: Cuvette. Md Rabiul Islam

Instrumental Technique: Cuvette. Md Rabiul Islam Instrumental Technique: Cuvette Md Rabiul Islam 16-7-2016 What is cuvette? A cuvette is a small tube of circular or square cross section, sealed at one end, made of plastic, glass, or fused quartz (for

More information

ab83360 Ammonia Assay Kit

ab83360 Ammonia Assay Kit Version 9 Last updated 7 February 2019 ab83360 Ammonia Assay Kit For the measurement of total ammonia and ammonium levels in various samples View kit datasheet: www.abcam.com/ab83360 (use www.abcam.cn/ab83360

More information

Human Scavenger Receptor B, SRB ELISA Kit Catalog No: E1530h 96 Tests Operating instruction

Human Scavenger Receptor B, SRB ELISA Kit Catalog No: E1530h 96 Tests Operating instruction DATA SHEET Human Scavenger Receptor B, SRB ELISA Kit Catalog No: E1530h 96 Tests Operating instruction FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE

More information

Investigating Food Dyes in Sports Beverages. Sample

Investigating Food Dyes in Sports Beverages. Sample Investigating Food Dyes in Sports Beverages Investigation 1 There are many different brands of beverages that fall under the general category of sports drinks. Most of these beverages contain an FD&C food

More information

NECi Nitrate Kits FAQs

NECi Nitrate Kits FAQs Why use enzymes? Enzymes are catalysts that drive complex biological reactions. They happen to be excellent reagents for analytical chemistry because they are reliable, accurate, sensitive, selective,

More information