Selecting Detectors for Compounds with No Optical Absorbance

Size: px
Start display at page:

Download "Selecting Detectors for Compounds with No Optical Absorbance"

Transcription

1 C146-E114 Selecting Detectors for Compounds with No Optical Absorbance Technical Report vol Features of Absorbance Detectors In HPLC, the detector is selected in accordance with the analyte. Many of the detectors used are based on optical absorbance, such as UV-Vis absorbance detectors and photodiode array (PDA) detectors. Absorbance detectors have the following features: The detector sensitivity and selectivity can be adjusted by setting an appropriate detector wavelength. The sensitivity is relatively high (although it depends on the molar extinction coefficient). The relationship between the elution concentration and the detection response is linear and covers a wide range (Lambert-Beer law). The gradient elution method can be used. The stability is high. The difference between instruments is small. They perform nondestructive detection and can therefore be used for fractionation. It is partly because of this large number of features and the consequent high level of versatility that absorbance detectors are used so widely. 2. Principle of Absorbance Detectors Fig. 1 illustrates the principle of absorbance detectors. When light of a certain wavelength is directed at a flow cell, the substance inside the flow cell absorbs the light. As a result, the intensity of the light that leaves the flow cell is less than that of the light that enters it. An absorbance detector measures the extent to which the light intensity decreases (i.e., the absorbance). During analysis, the mobile phase and sample continuously flow through the flow cell, and the data obtained by monitoring this absorbance in real time is represented as a chromatogram. As the absorbance varies in proportion to the compound concentration, the areas of the peaks in the chromatogram can be used to ascertain the concentrations of the target components. Ein Flow cell L Eout C: Concentration Absorbance Absorbance = C L = -log (Eout / Ein ) Time Fig. 1 Principle of Absorbance Detectors UV-Vis Absorbance Detector SPD-20A/20AV Photodiode Array Detector SPD-M20A Fig. 2 Absorbance Detectors

2 3. Limitations of Absorbance Detectors Although absorbance detectors are highly versatile and afford a high level of selectivity, they are not capable of handling every type of application. If the analyte (target compound) does not absorb UV light, then due to its operating principle, an absorbance detector cannot generate a peak for this compound. Techniques that can be used to analyze compounds that do not absorb UV light include the following: (1) Introduce chromophores to the target compound to derivatize it. (2) Use a detector other than an absorbance detector. Techniques that, like (1), use absorbance detectors together with derivatization have many advantages but they are not appropriate for situations where it is desirable or essential that the target compound is analyzed in its original state (i.e., intact). Also, the necessity of derivatization requires extra pretreatment before analysis. For this reason, in the analysis of target compounds with no absorbance, it is common to employ method (2), namely, use a detector based on a different detection principle. 4. What Kind of Detectors Complement Absorbance Detectors? If there were detectors that were as versatile as, and could compensate for the deficiencies of, absorbance detectors, then it would be possible to handle all types of compounds, including those with no absorbance. The following types of detectors are possible candidates for this role: (1) Refractive index detector Example: Shimadzu RID-10A Refractive Index Detector (2) Evaporative light scattering detector Example: Shimadzu ELSD-LT2 Evaporative Light Scattering Detector (3) Charged particle detector Example: ESA Biosciences Corona CAD * 1 (Charged Aerosol Detector) (4) Mass spectrometer (LCMS) Example: Shimadzu LCMS-2010EV Liquid Chromatograph Mass Spectrometer These detectors all have their own features and so, in order to ensure the successful analysis of target compounds, selection of the optimum detector should be based on a thorough understanding of the detectors' operating principles and features. Let us look, then, at the operation principle of each type of detector. Refractive Index Detector RID-10A Evaporative Light Scattering Detector ELSD-LT2 Charged Aerosol Detector Corona CAD Liquid Chromatograph Mass Spectrometer LCMS-2010EV Fig. 3: Detectors That Complement Absorbance Detectors 4-1. Principle of Refractive Index Detectors (RID) Fig. 4 illustrates the principle of RID. As shown in the left part of the figure, the "refractive index" is a measure of the extent to which the direction of light changes at the interface between two media when it passes from one medium into another. A RID uses difference in refractive index measured when the medium on the far side of the interface consists of mobile phase without eluted sample and mobile phase with eluted sample. As shown in the right part of the figure, the flow cell in a RID consists of two neighboring independent cells called the "reference cell" and the "sample cell". The reference cell contains only mobile phase, while the sample cell is part of the analysis flow line, so therefore contains both mobile phase and eluted sample. As the sample compounds separated in the column pass through the sample cell, the refractive index continuously changes. The amount of change is measured by the RID. As the refractive index varies in proportion to the compound concentration, the areas of the peaks in the chromatogram obtained can be used to ascertain the concentration of compounds. Incidence angle Air Refraction angle Water Sample cell Light-detection point Fig. 4: Principle of RID Reference cell Detection cell Light-receiving surface 4-2. Principle of Evaporative Light Scattering Detectors (ELSD) Fig. 5 illustrates the principle of ELSD. The column eluate that reaches the glass tube is nebulized by nitrogen gas that is simultaneously introduced into the tube, and then enters the drift tube. As the droplets flow through the drift tube, which is heated at a constant temperature, the mobile phase solvent evaporates, and as a result, the nonvolatile sample that remains takes the form of dust-like particles. In this state, the sample proceeds to the detection section. When the sample is exposed to light emitted from a light source, light is scattered, and the intensity of the scattered light is measured. Column eluate Fine droplets Glass tube Nitrogen gas Light-receiving unit Drift tube Nitrogen gas Minute particles of dried sample Fig. 5: Principle of ELSD 2

3 Thus, ELSD are based on the following principles: (1) The column eluate is nebulized by nitrogen gas, and converted to fine droplets. (2) When the fine droplets are heated, the mobile phase evaporates and minute particles of dried sample remain. (3) In the detection section, light is directed at the minute sample particles, and the intensity of the scattered light created by the collision between the particles and the light is measured. Light-receiving unit From drift tube Fig. 6: Detection Section in ELSD 4-3. Principle of Corona Charged Aerosol Detection Fig. 7 illustrates the principle of Corona CAD. Both Corona CAD and the ELSD described above use nebulization to form droplets. In a Corona CAD, nitrogen carrier gas is used to evaporate mobile phase solvent and convey the nonvolatile sample particles to a mixing chamber. A second stream of nitrogen gas acquires charge by passing over a corona discharge and collides with these analyte particles to form charged particles. These charged particles travel to the detection section, where the intensity of the current that they create is measured. In other words, the Corona CAD is based on the following principles: (1) The column eluate is nebulized by nitrogen gas, and converted to fine droplets. (2) When passing through a drying tube, the mobile phase evaporates and minute particles of dried sample remain. (3) The minute sample particles collide with charged nitrogen gas created by corona discharge and thereby become charged particles. (4) In the detection section, the intensity of the charged particles is measured. HPLC column eluate Gas inlet Large droplets to waste Nebulizer and impactor Drying tube Electrometer Charge Is measured by a sensitive electrometer Fig. 7: Principle of Corona CAD Signal out Signal is directly proportional to quantity of analyte in sample Collector Analyte particles transfer their charge Ion trap Negatively charged ion trap removes high-mobility particles Secondary gas stream positively charged Positive charge transferred by a high-voltage platinum Corona wire to analyte particles by charged opposing secondary gas stream 4-4. Principle of Mass Spectrometers (LCMS) As with the Corona CAD described above, mass spectrometers* 3 can also use Corona discharge to perform ionization for certain types of analyses. Mass spectrometers differ greatly from Corona CAD, however, in that the process starting with the mass separation performed after ionization and culminating with the final ion detection is carried out under vacuum conditions, and that separation is performed using the masses of the sample molecule ions mass to charge ratio (m/z). There are many different ionization methods that are used in mass spectrometry. Fig. 8 and Fig. 9 illustrate the APCI (atmospheric pressure chemical ionization) method, which is based on a principle similar to that used in Corona CAD. In a mass spectrometer, after the column eluate that reaches the ion source is heated and evaporated by a heater, it is nebulized with nitrogen gas. There is a Corona needle positioned at the outlet of the nebulizer, and the Corona discharge emitted from the tip of the needle causes the nitrogen gas and solvent molecules in the immediate vicinity to be ionized. Due to the exchange of protons between these reactant ions and the sample molecules, the sample molecules are ionized. The sample molecule ions then enter the ion focusing section, which is kept under vacuum, and the range of the direction of travel is narrowed. After the molecules are led into the mass separation section and separated according to mass, they travel to the detector, where their intensities are measured. In other words, mass spectrometers are based on the following principles: (1) After the column eluate is evaporated by heating, it is nebulized by nitrogen gas. (2) The sample molecules collide with reactant ions that are charged by Corona discharge, and are thereby ionized. (3) As the sample molecule ions pass through the mass separation section, they are separated according to mass. (4) In the detection section, the intensities of the sample molecule ions are measured. Ion source Ion focusing section Heater Vacuum Mass separation section Fig. 8: Principle of Mass Spectrometers Corona needle Fig. 9: Ion Source Used with APCI Method Detection section To mass separation section 3

4 5. Comparison of Detector Features In order to facilitate an understanding of the characteristics of the different detectors, such as mass spectrometers, Table 1 compares their properties, such as quantitative performance and selectivity, and other important points relevant to analysis, such as mobile phase restrictions. The evaluations presented here are general in nature, while in practice, the suitability of a given detector varies with the analyte. Table 1: Comparison of Detectors Detection Principle Versatility Polarity of Target Compound Sensitivity to Compounds of Medium Polarity Quantitative performance Dynamic Range Linearity Absorbance Detector Refractive Index Detector Absorbance intensity Refractive index Not applicable Evaporative Light Scattering Detector Scattered light intensity Medium polarity Charged Aerosol Detector Ion intensity Medium polarity Mass Spectrometer Ion intensity Medium/high polarity Stability Calibration Curve Selectivity Substances of Medium Polarity Ionization Ion Mass Log-log calibration curve required. Restrictions on Mobile Phase Nonvolatile Buffer Solutions Solvents with Absorbance Ultrapure Water Applicable Analyses Isocratic Analysis Gradient Analysis Yes Required No Yes Essential Multicomponent Simultaneous Analysis High-Throughput Analysis Ease of Use Stability Reproducibility Utilities (Nitrogen Gas) Not required Required 6. Important Points Concerning Detector Selection As can be seen from Table 1, there are various features that distinguish the different detectors, and in order to ensure that the analysis objective is attained, the optimum detector must be selected. Let us look at some of the points that must be considered when selecting a detector RID RID are very versatile because they can detect all compounds that have a different refractive index from the mobile phase. With GPC (gel permeation chromatography), for example, this characteristic is used effectively. However, because RID perform detection using the refractive index, they are subject to some restrictions. For example, it is difficult to improve the sensitivity and, because the refractive index changes if the relative proportion of the mobile phase changes, the gradient elution method cannot be used. Also, because these detectors are easily influenced by changes in temperature and pressure, various considerations must be addressed in order to obtain stable results. With Shimadzu's RID-10A refractive index detector, temperature fluctuation is suppressed with the adoption of a double temperature control mechanism. This means that, compared to other RID, the time required for stabilization with the RID-10A is relatively short and, because it is not easily influenced by temperature changes, stable data can be obtained. Optical system Heater Aluminum block Heat insulation material Fig. 10: Double Temperature Control Mechanism in RID-10A Optical System 4

5 6-2. ELSD, Corona CAD, and Mass Spectrometers Selection of an ELSD, a Corona CAD or mass spectrometer is appropriate if the sensitivity or stability provided with a RID is inadequate, or if gradient analysis is required. Because these three types of detectors use nebulization, their application is restricted to the use of mobile phases that do not contain nonvolatile salts or reagents. With HPLC analysis, because ph adjustment is extremely important for separation, phosphate and citrate buffer solutions are often used. If, however, these types of nonvolatile buffer solutions are used with a nebulization-type detector, the efficiency of the generation and desolvation of fine droplets by nebulization decreases significantly. Therefore, the following reagents are usually used with nebulization-type detectors: Acids: Acetic acid, formic acid, trifluoroacetic acid Bases: Ammonia (water), diethylamine, triethylamine Salts: Ammonium acetate, ammonium formate Ion-pair reagents: Fluorinated alkyl carboxylic acids such as pentafluorobutyric acid, alkylammoniums such as dibutylammonium acetate In addition, unless high purity water is used with these detectors, a high level of noise may be expected. Therefore, it is advisable to use water produced with an ultrapure water purification system. Furthermore, although there is no problem using organic solvents such as acetonitrile and methanol, as long as they are of HPLC grade, care is required when using solvents such as THF (tetrahydrofuran) because they may contain nonvolatile stabilizers. Nitrogen gas Glass tube Fig. 11: Nebulization Method Used in ELSD To drift tube 6-3. ELSD In addition to the points described above, ELSD also have the restriction of not being able to analyze volatile or sublimable compounds. This is because ELSD are only capable of detecting scattered light for compounds that are not removed by evaporation. Shimadzu's ELSD-LT 2* 4 evaporative light scattering detector can evaporate mobile phases at low temperatures and so it can be used for a wide range of mobile phases and target compounds. If the above restriction is overcome, ELSD have the following advantages over refractive index detectors: The sensitivity is 5 to 10 times higher. The gradient elution method can be used. They are not easily influenced by changes in temperature and pressure. These characteristics are utilized in the analysis of sugars, surfactants, lipids, and pharmaceutical products that have no chromophores. Fig. 12: Prominence ELSD-2 System 6-4. Corona CAD The Corona CAD detector is based on nebulization as in ELSD, and therefore is used in similar applications. Whereas ELSD optically measure scattered light, the Corona CAD detector performs electrical measurements for charged particles and so, in comparison to ELSD, attains higher sensitivity and a larger dynamic range Corona CAD and Mass Spectrometers Both the Corona CAD detector and mass spectrometers use corona discharge. A large amount of nitrogen is present in the area where corona discharge takes place and so reactive nitrogen ions (N2 + ) are generated. However the fundamental use of this phenomenon differs in the two techniques. Furthermore in mass spectrometers, if a protic solvent is present, ions such as H3O + and CH3OH2 + are generated. These ions become reactant ions, and the components separated in the column become ionized by a charge transfer process. However, not all compounds are ionized. Only compounds strong enough to take protons from the H3O + and CH3OH2 + ions (i.e., compounds with a high proton affinity) are ionized. The mass spectrometers have the restriction, then, that they cannot detect compounds that are not ionized. Because the Corona CAD detector does not operate in the same way as a mass spectrometer it does not have this restriction. Although mass spectrometers and Corona CAD have similarities, the process starting with the nebulization and culminating in detection differs greatly between the two types of detectors. With a Corona CAD, the total volume of the charged particles is used for the detection response, whereas with a mass spectrometer, the generated ions are detected after separation according to the mass-to-charge ratio (m/z). This is a fundamental difference and is extremely significant in terms of selectivity. 5

6 6-6. Mass Spectrometers Here we will look at important consideration in the selection of a mass spectrometer as a detector. (1) Application to Analysis of Impurities With other detectors, the chromatogram retention times are the only qualitative criteria available and so in the analysis of impurities, for example, impurities cannot be identified just by the retention time. With a mass spectrometer, however, estimation and identification are possible using information about the masses. Impurities can be estimated with the LCMS-2010EV single-stage quadrupole mass spectrometer or LC-MS/MS, and structual analysis is possible with the LCMS-IT-TOF ion-trap/time-of-flight hybrid mass spectrometer, which can perform accurate mass measurement and MS n analysis* 5. This is because mass spectrometry is a technique in which sample molecules are ionized, and after the generated sample molecule ions are separated according to mass-to-charge ratio (m/z), the ion intensities are measured, and so information about the masses of the sample compounds can be used. In other words, in situations where a high qualitative capability is required of analysis data, such as the analysis of impurities, it is important to select a mass spectrometer as the detector. Also, as they have a much higher detection sensitivity than other detectors, mass spectrometers could be described as ideal for the analysis of impurities. (2) Application to High-Throughput Analysis In applications such as high-throughput analysis and multicomponent simultaneous analysis, it is unlikely that complete separation is achieved for all compounds simply with column separation. In this kind of situation, the separation capacity of a mass spectrometer is an extremely effective tool for analysis requiring a higher level of selectivity. (3) Application to Thermally Labile Samples Mass spectrometers, the removal of the mobile phase (i.e., desolvation) is performed by heating. In the analysis of thermally labile compounds, however, it may not be possible to use this kind of heating. With mass spectrometers, replacing the ion source makes it possible to apply ESI (electrospray ionization), which does not involve heating, to thermally labile compounds. This means that mass spectrometers can be used for a wider range of applications than ELSD and Corona CAD. Drying gas Fig. 13: Ion Source Used in ESI Fig. 14: LCMS-2010EV System To mass separator *1: ESA, Corona, CAD, arec registered trademark of ESA Biosciences, Inc. All other trade names, trademarks, and registered trademarks are the property of their respective holders. *2: Source: P. Garnache, R. McCarthy, S. Freeto, D. Asa, D.M. Woodcock, K. Laws, and R. Cole: HPLC Analysis of Nonvolatile Analytes Using Charged Aerosol Detection. LCGC North America 23(2), (2005) *3: In this report, "mass spectrometry" refers to mass spectrometry based on APCI unless stated otherwise. *4: Refer to Technical Report vol. 6, "Principles and Practical Applications of Shimadzu s ELSD-LT2 Evaporative Light Scattering Detector". *5: Refer to Technical Report vol. 3, "Structural Prediction of Impurities in Drugs using MS n Data". Or refer to Technical Report vol.16, "Structural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS". The information contained in this report is protected by copyright by the publisher, Shimadzu Corporation ( Shimadzu ). The sale, use, reproduction or alteration of this information for any purpose is forbidden without Shimadzu s express written consent, which may be granted or withheld in Shimadzu s sole discretion. Moreover, although the information contained herein has been reviewed, Shimadzu makes no warranty or representation as to its accuracy or completeness. Therefore, if some sort of business or contract is to be entered into in reliance upon this published report and the information contained therein, a Shimadzu business representative must be contacted beforehand for authorization and contractual purposes. This report was created based upon information available to Shimadzu when it was issued, and Shimadzu reserves the right to make revisions to the form and content of this published report without prior notice. First Edition: January, 2008 Founded in 1875, Shimadzu Corporation, a leader in the development of advanced technologies, has a distinguished history of innovation built on the foundation of contributing to society through science and technology. We maintain a global network of sales, service, technical support and applications centers on six continents, and have established long-term relationships with a host of highly trained distributors located in over 100 countries. For information about Shimadzu, and to contact your local office, please visit our Web site at JQA-0376 SHIMADZU CORPORATION. International Marketing Division 3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo , Japan Phone: 81(3) Fax. 81(3) URL The contents of this brochure are subject to change without notice. Printed in Japan ANS

Structural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS

Structural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS C146-E118 Structural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS Technical Report vol.16 1. Introduction MetID Solution is a software application that was developed

More information

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD) The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD) Basically all compounds which are less volatile than the mobile phase can be detected. Detection is based on a Universal property of

More information

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Chemistry Instrumental Analysis Lecture 37. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 37 Most analytes separated by HPLC are thermally stable and non-volatile (liquids) (unlike in GC) so not ionized easily by EI or CI techniques. MS must be at

More information

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography Tips and Techniques to Optimize ELSD and MS based Purification Utilizing ELSD and MS as Secondary Detectors for Prep

More information

M M e M M H M M H. Ion Sources

M M e M M H M M H. Ion Sources Ion Sources Overview of Various Ion Sources After introducing samples into a mass spectrometer, the next important step is the conversion of neutral molecules or compounds to gas phase ions. The ions could

More information

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC INTRODUCTION Principle: LC/MS is a technique that combines physical separation capabilities of liquid

More information

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection Ian Acworth, Bruce Bailey, Paul Gamache, and John Waraska Thermo Fisher Scientific, Chelmsford, MA, USA Introduction

More information

TANDEM MASS SPECTROSCOPY

TANDEM MASS SPECTROSCOPY TANDEM MASS SPECTROSCOPY 1 MASS SPECTROMETER TYPES OF MASS SPECTROMETER PRINCIPLE TANDEM MASS SPECTROMETER INSTRUMENTATION QUADRAPOLE MASS ANALYZER TRIPLE QUADRAPOLE MASS ANALYZER TIME OF FLIGHT MASS ANALYSER

More information

Routine MS Detection for USP Chromatographic Methods

Routine MS Detection for USP Chromatographic Methods Daniel S. Root, Thomas E. Wheat, and Patricia McConville Waters Corporation, Milford, MA, USA APPLICATION BENEFITS This approach enables mass spectral analysis of peaks directly from unmodified USP HPLC

More information

HPLC Analysis of Nonvolatile Analytes Using Charged Aerosol Detection

HPLC Analysis of Nonvolatile Analytes Using Charged Aerosol Detection 150 LCGC NORTH AMERICA VOLUME 23 NUMBER 2 FEBRUARY 2005 www.chromatographyonline.com HPLC Analysis of Nonvolatile Analytes Using Charged Aerosol Detection A new detection method based upon aerosol charging

More information

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

Selecting an LC/MS Interface Becky Wittrig, Ph.D. Selecting an LC/MS Interface Becky Wittrig, Ph.D. RESTEK CORPORATION LC/MS Interfaces I. Background of LC/MS I. Historical Perspective II. Reasons for use II. Interfaces I. Transport devices II. Particle

More information

HPLC Analysis of Non-volatile Analytes Using

HPLC Analysis of Non-volatile Analytes Using HPLC Analysis of Non-volatile Analytes Using Charged Aerosol Detection Paul H. Gamache, Ryan S. McCarthy, Scott M. Freeto, Darwin J. Asa, Matthew J. Woodcock, Katherine Laws and Roderic O. Cole ESA Inc.,

More information

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis Application Note AN89.V.1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Page 1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Prior to LC-MS/MS Analysis Sample Preparation

More information

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics Mass spectrometry (MS) is the technique for protein identification and analysis by production of charged molecular species in vacuum, and their separation by magnetic and electric fields based on mass

More information

HPLC solvents and mobile phase additives

HPLC solvents and mobile phase additives HPLC solvents and mobile phase additives The following is intended to be a guide for the choice of solvent and mobile phase additives. Of course the choice of solvents for LC will be dictated primarily

More information

Electrospray Ion Trap Mass Spectrometry. Introduction

Electrospray Ion Trap Mass Spectrometry. Introduction Electrospray Ion Source Electrospray Ion Trap Mass Spectrometry Introduction The key to using MS for solutions is the ability to transfer your analytes into the vacuum of the mass spectrometer as ionic

More information

Analysis of Polar Metabolites using Mass Spectrometry

Analysis of Polar Metabolites using Mass Spectrometry Analysis of Polar Metabolites using Mass Spectrometry TransMed Course: Basics in Clinical Proteomics and Metabolomics. Oct 10-19, 2012 dd.mm.yyyy Vidya Velagapudi, Ph.D, Adjunct Professor Head of the Metabolomics

More information

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core

More information

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC LC800 Smart HPLC Until now UHPLC From now Smart HPLC Smart HPLC Leads to Ultimate Performance Patent Pending S LC800 is a completely new and unique concept, designed for maximum performance in high resolution

More information

No Chromophore? No Problem! Universal HPLC Detection. The world leader in serving science

No Chromophore? No Problem! Universal HPLC Detection. The world leader in serving science No Chromophore? No Problem! Universal HPLC Detection The world leader in serving science Topics Key concepts behind Thermo Scientific Charged Aerosol Detection (CAD) Universal Detection and Uniform Response

More information

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Applied Biosystems QStar Pulsar i Features of the API QSTAR Pulsar i The

More information

Hypericin Analysis by LC/MS

Hypericin Analysis by LC/MS Hypericin Analysis by LC/MS Jeanne B. Li and Michael P. Balogh LC/MS Waters Corporation LC GC, Vol 17, No. 6, June 1999 Introduction to hypericin analysis by LC/MS Hypericin and Related Compounds O Protohypericin

More information

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA Use of High Speed/High Resolution Size-Based Chromatographic Separation of Surfactants and Oligomeric Materials with Single Quadrupole Mass Spectrometry Michael O Leary, Jennifer Gough, Tanya Tollifson

More information

Mass Spectrometry in MCAL

Mass Spectrometry in MCAL Mass Spectrometry in MCAL Two systems: GC-MS, LC-MS GC seperates small, volatile, non-polar material MS is detection devise (Agilent 320-MS TQ Mass Spectrometer) Full scan monitoring SIM single ion monitoring

More information

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science C101-E112 BioSpec-nano Shimadzu Spectrophotometer for Life Science Power of small. BioSpec-nano BioSpec-nano Shimadzu Spectrophotometer for Life Science Quick and Simple Nucleic Acid Quantitation Drop-and-Click

More information

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS Liquid Chromatography Mass Spectrometry SSI-LCMS-096 Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS LCMS-8045 Summary: A short, robust quantitative method for the analysis

More information

HPLC Workshop 16 June 2009 What does this do? Chromatography Theory Review Several chromatographic techniques Even though each method utilizes different techniques to separate compounds, the principles

More information

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF application Note Liquid Chromatography/ Mass Spectrometry Author Sharanya Reddy PerkinElmer, Inc. Shelton, CT USA Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

More information

MODERN HPLC FOR PRACTICING SCIENTISTS

MODERN HPLC FOR PRACTICING SCIENTISTS MODERN HPLC FOR PRACTICING SCIENTISTS Michael W. Dong Synomics Pharmaceutical Services, LLC Wareham, Massachusetts WILEY- INTERSCIENCE A JOHN WILEY & SONS, INC., PUBLICATION Preface xv 1 Introduction 1

More information

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365 Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365 Effortless Performance The LCMS-9030 quadrupole time-of-flight (Q-TOF) mass spectrometer integrates the world s fastest

More information

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for Clinical Toxicology Page of 0 Materials and Methods Biomass Component Extraction: The uneaten cooked plant specimen was prepared for chemical analysis as follows. The sample was frozen, diced, pulverized

More information

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Application Note EPA Method 535 EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS API 3200 LC/MS/MS System Overview Described here is the

More information

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS Application Note Traditional Chinese Medicine Author Rongjie Fu Agilent Technologies

More information

Quantitation of Surfactants in Samples by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Quantitation of Surfactants in Samples by High Performance Liquid Chromatography and Corona Charged Aerosol Detection Quantitation of Surfactants in Samples by High Performance Liquid Chromatography and Corona Charged Aerosol Detection Marc Plante, Bruce Bailey, and Ian N. Acworth Thermo Fisher Scientific, Chelmsford,

More information

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution Marc Plante, Bruce Bailey, Christopher Crafts, Ian N. Acworth Thermo Fisher Scientific, Chelmsford,

More information

Agilent G3212 GC-APCI Source

Agilent G3212 GC-APCI Source Agilent G3212 GC-APCI Source Quick Start Guide Where to find information 2 Getting Started 3 Step 1. Start the Data Acquisition program for the GC and the Q-TOF 3 Step 2. Prepare the GC and Q-TOF for data

More information

BIOINF 4399B Computational Proteomics and Metabolomics

BIOINF 4399B Computational Proteomics and Metabolomics BIOINF 4399B Computational Proteomics and Metabolomics Sven Nahnsen WS 13/14 3. Chromatography and mass spectrometry Overview Recall last lecture Basics of liquid chromatography Algorithms to predict and

More information

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Q&A Transcript ---------------- Q - How do you generate multiple charges reproductively? A - If you use the same settings on the

More information

Technical Note. Introduction

Technical Note. Introduction Technical Note Analysis and Characterization of Psilocybin and Psilocin Using Liquid Chromatography - Electrospray Ionization Mass Spectrometry (LC-ESI-MS) with Collision-Induced-Dissociation (CID) and

More information

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada) Quantitation and Identification of Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples using Advanced TripleTOF MS/MS Technology André Schreiber AB SCIEX Concord, Ontario (Canada)

More information

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma Jon Bardsley 1, James Goldberg 2 1 Thermo Fisher Scientific, Runcorn, UK; 2 Thermo Fisher Scientific, West Palm Beach,

More information

Evaporative Light Scattering Detector (ELSD)

Evaporative Light Scattering Detector (ELSD) BÜCHI Labortechnik AG Evaporative Light Scattering Detector (ELSD) Martin Verstegen ELSD 3300 page 1 Overview of Common HPLC Detectors 1. UV/Vis 2. RI 3. Fluorescence 4. Mass Spectrometry 5. ELSD page

More information

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved We have made it easy for you to find a PDF Ebooks without any digging. And by having access

More information

LC-MS Based Metabolomics

LC-MS Based Metabolomics LC-MS Based Metabolomics Analysing the METABOLOME 1. Metabolite Extraction 2. Metabolite detection (with or without separation) 3. Data analysis Metabolite Detection GC-MS: Naturally volatile or made volatile

More information

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity Janet Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS High

More information

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer APPLICATION NOTE 72385 Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer Authors Stephan Meding, Katherine Lovejoy, Martin Ruehl Thermo Fisher Scientific,

More information

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION Quantitation by High Resolution Mass Spectrometry: Using Target Enhancement and Tof-MRM to Achieve Femtogram-level On-column Sensitivity for Quantitation of Drugs in Human Plasma Yun W. Alelyunas, Mark

More information

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved We have made it easy for you to find a PDF Ebooks without any digging. And by having access

More information

TR ACE ORGANIC. lgcstandards.com/foodandenvironment

TR ACE ORGANIC. lgcstandards.com/foodandenvironment U S E O F S TA B L E I S OTO P E I NTE R N A L S TA N D A R D S F O R TR ACE ORGANIC A N A LY S I S lgcstandards.com/foodandenvironment dr.ehrenstorfer@lgcgroup.com This paper explains why stable isotope

More information

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection Mark Tracy, Xiaodong Liu, and Ian Acworth, Thermo Fisher Scientific, Sunnyvale, CA,

More information

Discover what you re missing

Discover what you re missing Discover what you re missing Thermo Scientific Corona Veo Charged Aerosol Detector Hidden peaks revealed The analyte detection challenge No single liquid chromatography (LC) detector delivers ideal results.

More information

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer 38 Current Trends in Mass Spectrometry November 6 Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer This article demonstrates the improved

More information

Questions on Instrumental Methods of Analysis

Questions on Instrumental Methods of Analysis Questions on Instrumental Methods of Analysis 1. Which one of the following techniques can be used for the detection in a liquid chromatograph? a. Ultraviolet absorbance or refractive index measurement.

More information

Varian 385-LC. ELSD for Low Molecular Weight Compounds

Varian 385-LC. ELSD for Low Molecular Weight Compounds D ATA S H E E T Varian 8-LC EVAPORATIVE LIGHT SCATTERING DETECTOR ELSD for Low Molecular Weight Compounds Evaporative light scattering detectors are ideal for detecting analytes with no UV chromophore

More information

Accurate Mass Analysis of Hydraulic Fracturing Waters

Accurate Mass Analysis of Hydraulic Fracturing Waters Application Note Environmental Accurate Mass Analysis of Hydraulic Fracturing Waters Using the Kendrick mass defect with the Agilent LC/Q-TOF MS Authors E. Michael Thurman and Imma Ferrer Department of

More information

1. The range of frequencies that a measurement is sensitive to is called the frequency

1. The range of frequencies that a measurement is sensitive to is called the frequency CHEM 3 Name Exam 1 Fall 014 Complete these problems on separate paper and staple it to this sheet when you are finished. Please initial each sheet as well. Clearly mark your answers. YOU MUST SHOW YOUR

More information

C101-E111. Talk Letter. Vol.2 February 2009

C101-E111. Talk Letter. Vol.2 February 2009 C101-E111 UV Talk Letter Vol.2 February 2009 UV Talk Letter UV Talk Letter The Structure of a Spectrophotometer Vol.2 February 2009 1.The Measurement Principle Used by a Spectrophotometer The basic measurement

More information

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Analysis - HPLC A.136. Primesep 5 µm columns B.136 Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using

More information

GPC/MS. Analysis of PET

GPC/MS. Analysis of PET Recent Developments in:- GPC/MS High Temperature ELSD Analysis of PET Graham Cleaver BWM Overview Coupling GPC with APCI Mass Spectrometry To identify the number of oligomers in a low molecular weight

More information

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS) Liquid Chromatography Mass Spectrometry (LC/MS) Prelab Questions: Questions to be answered before doing the experiment. The answers are due at the beginning of each experiment without exception (the questions

More information

Peptide Isolation Using the Prep 150 LC System

Peptide Isolation Using the Prep 150 LC System Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System, an affordable, highly reliable system for preparative chromatography, is suitable

More information

Introduction. Chapter 1. Learning Objectives

Introduction. Chapter 1. Learning Objectives Chapter 1 Introduction Learning Objectives To understand the need to interface liquid chromatography and mass spectrometry. To understand the requirements of an interface between liquid chromatography

More information

Chromatographic Analysis

Chromatographic Analysis Chromatographic Analysis Distribution of Analytes between Phases An analyte is in equilibrium between the two phases [S 1 ] [S 2 ] (in phase 1) (in phase 2) AS [S2 ] K 2 A S [S1 ] 1 AS, A 1 S Activity

More information

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS APPLICATION NOTE Liquid Chromatography/ Mass Spectrometry Authors: Roberto Troiano Milan, Italy Wilhad M. Reuter Shelton, CT Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS Introduction

More information

IN QUALITATIVE ANALYSIS,

IN QUALITATIVE ANALYSIS, IN QUALITATIVE ANALYSIS, YOU VE ALWAYS HAD TO CHOOSE BETWEEN ACCURACY AND THROUGHPUT. NOW THERE S NO REASON TO ever have to. WATERS QUALITATIVE ANALYSIS solutions Waters ACQUITY UPLC System with the Waters

More information

Biochemistry. Biochemical Techniques HPLC

Biochemistry. Biochemical Techniques HPLC Description of Module Subject Name Paper Name 12 Module Name/Title 13 1. Objectives 1.1. To understand the basic concept and principle of 1.2. To understand the components and techniques of 1.3. To know

More information

Molecular Mass Spectrometry

Molecular Mass Spectrometry Molecular Mass Spectrometry Mass Spectrometry: capable of providing information about (1) Elemental composition of samples of matter: atomic mass (2) Structures of inorganic, organic, and biological molecules

More information

Analysis of Organic Light Emitting Diode Materials by UltraPerformance Convergence Chromatography Coupled with Mass Spectrometry (UPC 2 /MS)

Analysis of Organic Light Emitting Diode Materials by UltraPerformance Convergence Chromatography Coupled with Mass Spectrometry (UPC 2 /MS) Analysis of Organic Light Emitting Diode Materials by UltraPerformance Convergence Chromatography Coupled with Mass Spectrometry (UPC 2 /MS) Michael D. Jones, Andrew Aubin, Peter J. Lee, and Tim Jenkins

More information

Agilent 385-ELSD Evaporative Light Scattering Detector

Agilent 385-ELSD Evaporative Light Scattering Detector Agilent 8-ELSD Evaporative Light Scattering Detector For Low Molecular Weight Compounds Data Sheet Introduction Evaporative light scattering detectors are ideal for detecting analytes with no UV chromophore

More information

C101-E116. Talk Letter. Vol.4 March 2010

C101-E116. Talk Letter. Vol.4 March 2010 C101-E116 UV Talk Letter Vol.4 March 2010 UV UV Talk Letter Detectors Talk Letter Vol.4 March 2010 In the context of spectrophotometers, the term "detector" refers to a light-receiving element that absorbs

More information

Varian 380-LC. ELSD for Routine HPLC and GPC Analysis. Key Benefits

Varian 380-LC. ELSD for Routine HPLC and GPC Analysis. Key Benefits D ATA S H E E T EVAPORATIVE LIGHT SCATTERING DETECTOR ELSD for Routine HPLC and GPC Analysis Evaporative light scattering detectors are ideal for detecting analytes with no UV chromophore as they do not

More information

Choosing the metabolomics platform

Choosing the metabolomics platform GBS 748 Choosing the metabolomics platform Stephen Barnes, PhD 4 7117; sbarnes@uab.edu So, I have my samples what s next? You ve collected your samples and you may have extracted them Protein precipitation

More information

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Application Note: 3 Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Yoko Yamagishi, Thermo Fisher Scientific, C-2F 3-9

More information

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539) Determination of ormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell P Column (EPA 539) Application Note Environmental Authors Rong-jie Fu and Chen-ao (Andy) Zhai Agilent Technologies

More information

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Christopher Borton AB SCIEX Golden, Colorado verview Described here is the analysis of

More information

CHROMATOGRAPHY AND MASS SPECTROMETER

CHROMATOGRAPHY AND MASS SPECTROMETER 22 CHROMATOGRAPHY AND MASS SPECTROMETER 22.1 INTRODUCTION We know that the biochemistry or biological chemistry deals with the study of molecules present in organisms. These molecules are called as biomolecules

More information

FLUDEOXYGLUCOSE ( 18 F) INJECTION: Final text for addition to The International Pharmacopoeia (January 2009)

FLUDEOXYGLUCOSE ( 18 F) INJECTION: Final text for addition to The International Pharmacopoeia (January 2009) January 2009 FLUDEOXYGLUCOSE ( 18 F) INJECTION: Final text for addition to The International Pharmacopoeia (January 2009) This monograph was adopted at the Forty-third WHO Expert Committee on Specifications

More information

2501 High Performance Liquid Chromatography

2501 High Performance Liquid Chromatography 2501 High Performance Liquid Chromatography High Performance Liquid Chromatography Scheme Chp25:: 1 High Performance Liquid Chromatography Components of HPLC High Performance Liquid Chromatography Scheme

More information

UPLC Intact MASS Analysis Application Kit

UPLC Intact MASS Analysis Application Kit (Part Number: 176001519) CONTENTS I. INTACT MASS ANALYSIS APPLICATION KIT COMPONENTS II. INSTALLING THE PRE-COLUMN TUBING INTO MASSPREP MICRO DESALTING COLUMN III. CONNECTING THE COLUMN TO LCT PREMIER

More information

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide What is the MassHunter METLIN Metabolite PCD/PCDL? 2 Where to find more information 2 Kit Content 3 Installation 5 Before you start 5 Install MassHunter

More information

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD) Agilent 16 Infinity Evaporative Light Scattering Detector (ELSD) Data Sheet Introduction Evaporative light scattering detectors (ELSDs) are ideal for detecting analytes with no UV chromophore as they do

More information

Charged Aerosol Detection: Factors for consideration in its use as a generic quantitative detector

Charged Aerosol Detection: Factors for consideration in its use as a generic quantitative detector Charged Aerosol Detection: Factors for consideration in its use as a generic quantitative detector Ian Sinclair and Richard Gallagher - Global Compound Sciences/DMPK, AstraZeneca, Mereside, Alderley Park,

More information

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS Improved Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS Abstract In this work, we demonstrate an improved automated sample preparation for liquid chromatography-tandem mass spectrometry

More information

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS Application Note Food Testing and Agriculture Author Chen-Hao (Andy) Zhai and Rong-jie Fu Agilent Technologies (Shanghai)

More information

Evaluation of a novel glass vial overcoming adsorption effect for pharmaceutical drugs

Evaluation of a novel glass vial overcoming adsorption effect for pharmaceutical drugs PO-CON1577E Evaluation of a novel glass vial overcoming adsorption effect for pharmaceutical drugs HPLC 215 PSB-PHARM-17 Minori Nakashima*(1), Yuki Sato (2,3), Takeshi Kuwahara (3), Azusa Uchida (1), Takenao

More information

Agilent 385-ELSD Evaporative Light Scattering Detector

Agilent 385-ELSD Evaporative Light Scattering Detector Agilent 8-ELSD Evaporative Light Scattering Detector For Low Molecular Weight Compounds Data Sheet Introduction Evaporative light scattering detectors are ideal for detecting analytes with no UV chromophore

More information

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Marian Twohig, Michael D. Jones, Dominic Moore, Peter Lee, and Robert Plumb Waters Corporation, Milford, MA, USA APPLICATION

More information

Chromatography & instrumentation in Organic Chemistry

Chromatography & instrumentation in Organic Chemistry Chromatography & instrumentation in Organic Chemistry What is Chromatography? Chromatography is a technique for separating mixtures into their components in order to analyze, identify, purify, and/or quantify

More information

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph SCIETIFIC ISTRUMET EWS 2016 Vol. 7 SEPTEMBER Technical magazine of Electron Microscope and Analytical Instruments. Technical Explanation Introduction of Hitachi Chromaster 5610 MS Detector for High Performance

More information

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate Michael D. Jones, Xiang Jin Song, Robert S. Plumb, Peter J. Lee, and

More information

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n 20.2 Ion Sources electron ionization produces an M + ion and extensive fragmentation chemical ionization produces an M +, MH +, M +, or M - ion with minimal fragmentation MALDI uses laser ablation to transfer

More information

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis Application Note AN785 Extraction of Aflatoxins and chratoxin From Dried Chili Using ISLUTE Myco prior to LC-MS/MS Analysis Page Extraction of Aflatoxins and chratoxin from Dried Chili Using ISLUTE Myco

More information

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW Paula Hong, John Van Antwerp, and Patricia McConville Waters Corporation, Milford, MA, USA Historically UV detection has been

More information

Direct Analysis of Surfactants using HPLC with Charged Aerosol Detection

Direct Analysis of Surfactants using HPLC with Charged Aerosol Detection Direct Analysis of Surfactants using HPLC with Charged Aerosol Detection Marc Plante, Bruce Bailey, Ian N. Acworth, Christopher Crafts, Thermo Fisher Scientific, Chelmsford, MA, USA Overview Purpose: Examples

More information

Introduction to Chromatography

Introduction to Chromatography Introduction to Chromatography Dr. Sana Mustafa Assistant Professor Department of Chemistry, Federal Urdu University of Arts, Science & Technology, Karachi. What is Chromatography? Derived from the Greek

More information

LC MS analysis of metabolites. Basis of Chromatography

LC MS analysis of metabolites. Basis of Chromatography GBS 724 LC MS analysis of metabolites Stephen Barnes, PhD 4 7117; sbarnes@uab.edu Basis of Chromatography A moving (mobile) phase passes over an inert, stationary phase The compounds differentially interact

More information

The Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics

The Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics APPLICATION NOTE TOF MS The Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics Purpose The Applied Biosystems 4700

More information

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Chemistry Instrumental Analysis Lecture 34. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 34 From molecular to elemental analysis there are three major techniques used for elemental analysis: Optical spectrometry Mass spectrometry X-ray spectrometry

More information

Introduction to Pharmaceutical Chemical Analysis

Introduction to Pharmaceutical Chemical Analysis Introduction to Pharmaceutical Chemical Analysis Hansen, Steen ISBN-13: 9780470661222 Table of Contents Preface xv 1 Introduction to Pharmaceutical Analysis 1 1.1 Applications and Definitions 1 1.2 The

More information

Use of Charged Aerosol Detection as an Orthogonal Quantification Technique for Drug Metabolites in Safety Testing (MIST)

Use of Charged Aerosol Detection as an Orthogonal Quantification Technique for Drug Metabolites in Safety Testing (MIST) Use of harged Aerosol Detection as an rthogonal Quantification Technique for Drug Metabolites in Safety Testing (MIST) hristopher rafts, Bruce Bailey, Marc Plante, John Waraska, Paul Gamache, and Ian Acworth

More information