Atmospheric Environment

Size: px
Start display at page:

Download "Atmospheric Environment"

Transcription

1 Atmospheric Environment 66 (2013) 25e32 Contents lists available at SciVerse ScienceDirect Atmospheric Environment journal homepage: Techniques for measuring particle size distribution of particulate matter emitted from animal feeding operations Lingjuan Wang-Li a, *, Zihan Cao a, Michael Buser b, Derek Whitelock c, Calvin B. Parnell d, Yuanhui Zhang e a Department of Biological and Agricultural Engineering, North Carolina State University, Raleigh, NC 27695, USA b Department of Biosystems and Agricultural Engineering, Oklahoma State University, USA c Agricultural Research Service, U.S. Department of Agriculture, Las Cruces, NM, USA d Department of Biological and Agricultural Engineering, Texas A&M University, USA e Department of Agricultural and Biological Engineering, University of Illinois at Urbana-Champaign, USA highlights < Particle size distributions of PM samples were analyzed by four analyzers. < Significant differences in PSD measurements were observed. < Laser diffraction analyzers provided greater and broader PSDs than ESZ analyzer. < Measured PM 2.5 mass fractions differed from the lognormal fitting PM 2.5 fractions. article info abstract Article history: Received 3 April 2012 Received in revised form 21 August 2012 Accepted 25 August 2012 Keywords: Particulate matter Animal feeding operation Particle size distribution analyzer Laser diffraction Electrical sensing zone PM 10 mass fraction PM 2.5 mass fraction While various techniques for measuring particle size distributions (PSD) of particulate matter (PM) exist, there is no a single agreed upon standard or reference method for PM with different characteristics. This study investigated differences in the PSD measurements by four PSD analyzers: LS multi-wave length laser diffraction particle size analyzer, LS230 laser diffraction particle size analyzer, LA-300 laser scattering particle size analyzer, and Coulter Counter Multisizer3 (CCM3). Simultaneously collected total suspended particulate (TSP) samples in a commercial egg production house were analyzed by the four analyzers for PSDs. In addition, four types of testing powders (limestone, starch, No.3 micro aluminum, and No.5 micro aluminum) were also analyzed by these four PSD analyzers. The results suggest when comparing measured mass median diameters (MMDs) and geometric standard deviations (GSD) of the PSDs, the laser diffraction method (LS13 320, LS230 and LA-300) provided larger MMDs and broader distributions (GSDs) than the electrical sensing zone method (CCM3) for all samples. When comparing mass fractions of PM 10 and PM 2.5 between the measured values and the lognormal fitting values derived from the measured MMDs and GSDs, lognormal fitting method produced reasonably accurate PM 10 mass fraction estimations (within 5%), but it failed to produce accurate PM 2.5 mass fraction estimations. The measured PM 2.5 mass fractions significantly differed from the lognormal fitting PM 2.5 fractions and the mean differences reached as high as 95%. It is strongly recommended that when reporting a PSD of certain PM samples, in addition to MMD and GSD, the mass fractions of PM 10 and PM 2.5 should also be reported. Ó 2012 Elsevier Ltd. All rights reserved. 1. Introduction As a criteria pollutant, particulate matter (PM) has been a research topic for numerous studies in the context of air pollution. The studies of health impacts, emission estimation of PM, and * Corresponding author. Tel.: þ ; fax: þ address: Lwang5@ncsu.edu (L. Wang-Li). development of new control technologies require knowledge of PM characteristics. Among these PM characteristics, the particle size distribution (PSD) is perhaps the most important physical parameter governing particle behavior. Various methods and techniques are available for conducting PSD analyses. Advantages and disadvantages associated with each method exist. Unfortunately, there is no single agreed upon method to determine the PSD of PM emitted from difference sources /$ e see front matter Ó 2012 Elsevier Ltd. All rights reserved.

2 26 L. Wang-Li et al. / Atmospheric Environment 66 (2013) 25e32 In the literature, the commonly used techniques for PSD measurements can be classified into five categories based upon the principals applied in particle size measurements (Hinds, 1999): (1) aerodynamic method, including aerodynamic particle sizer (APS) and various cascade impactors; (2) optical method, including various optical particle counters, light scattering and laser diffraction particle size analyzers; (3) electrical sensing zone method, i.e. Coulter Counter; (4) electrical mobility and condensation method, e.g. differential mobility analyzer (DMA) plus condensation nuclei counter (CNC); (5) electron microscopy. The APS measures the aerodynamic equivalent diameter (AED) of individual particles using the time-of-flight principle (Hinds, 1999; Mitchell and Nagel, 1999; Peters and Leith, 2003). It has a particle size measurement range of 0.5e20 mm. The cascade impactor method uses the principle of inertia to separate PM into different particle size ranges based upon different cut-off sizes at different impaction stages connected in series (Hinds, 1999). The impactor method provides onsite PSD measurement of airborne particles, but the PSD classification of this method can only include a small number of size classes. The inertial removal may cause inter-stage loss due to sharp bends in the inter-stage flow path. The optical particle counters (OPCs) are used most frequently for measuring number concentrations corresponding to different size classes. While they can provide real-time concentrations and size measurements of airborne particles, they are not intended for use on larger particles or in hostile environments with high levels of PM and gaseous pollutants (Parker et al., 2009). In light scattering particle size analyzers, for particles larger than the light wavelength, Mie scattering theory is applied to determine the angular distribution of scattered lights by particles suspended in a solvent. This angular distribution of the scattered lights is a very sensitive indicator of PSD (Hinds, 1999). In this method, knowledge of the refractive index of the particle and the solvent is required to solve Mie equations for determination of the scattered light angular distribution. It was reported (Xu and Guida, 2003) that the light scattering method may provide more reliable PSD measurements on account of ease of use and broad size ranges, from sub-micrometers to millimeters. On the other hand, the light scattering methods are typically limited to measuring particles greater than 0.3 mm due to reduced detection efficiency with smaller particle size and errors caused by particle shape and refractive index variations. In particle size measurements of airborne particles, the light scattering analyzers measure PSDs from PM samples taken using gravimetric collection techniques. Thus, the light scattering analyzers don t provide real-time PSD measurements. In this method, PM samples need to be extracted from filter media into a solvent for PSD analysis. Consequently, this method is only suitable for insoluble particles. All the optical analyzers provide PSD measurements in equivalent spherical diameter (ESD), not AED. Information of particle shape and density is needed to convert ESD to AED. The electrical sensing zone (ESZ) method is also known as the Coulter Counter method (Xu and Guida, 2003; Lines et al., 1996). In a Coulter Counter, the particles suspended in an electrolyte solution are forced to pass through a small aperture where an electric field is applied. The solution s conductance changes as the particles pass through the aperture. The change in conductance is a function of particle size. When particles pass through the aperture, the particles individual volumes are directly measured. This method measures a single particle s volume and provides high resolution and reproducibility for individual particle size assessment in ESD (Lines et al., 1996). However, particles that can be analyzed are restricted to those that can be dispersed in an electrolyte solution and still retain their original integrity. Like the light scattering particle size analyzers, the Coulter Counter also analyze PSDs of airborne particles from samples taken using gravimetric collection techniques. Thus, this method does not provide real-time measurements of PSDs either. The electrical mobility depends on the electric mobility of the particles for PSD measurement and it can only work well for particles with good mobility. The electron microscopy method is capable of providing both particle size and morphology information. However, this method could not provide sufficient statistical representation of particle measurements to derive a PSD for a PM sample. It is not appropriate for continuous or long term PSD analysis. Due to lack of a standardized method for PSD measurements in different applications, efforts have been made to compare PSD results measured by some aforementioned methods. When both cascade impactor and laser diffraction particle size analyzer (one type of light scattering analyzers) were used to evaluate PSDs of particles generated by nebulizers (Ziegler and Wachtel, 2005; Smyth and Hickey, 2003), the results of PSDs measured by both of these two techniques correlated with each other very well. In comparison of the light scattering method and the ESZ method, Xu and Guida (2003) reported that the laser diffraction particle size analyzer provided much larger mean sizes and broader distributions for irregular particles when compared with the Coulter Counter. Similar finding was also reported by Jerez et al. (2011) in a study of PSDs in a swine building. When compared the ESZ with other two methods, McClure (2009) found that the Coulter Counter (ESZ method) compared well to APS, whereas Xu and Guida (2003) discovered that the ESZ produced compatible results with dynamic image analysis, which are much less affected by particle shape (Xu and Guida, 2003). In general, particle size results of non-spherical particles measured by different instruments are often less consistent when compared with each other (Xu and Guida, 2003). The objectives of this reported study were to (1) investigate differences of PSDs measured by different particle size analyzers using either laser diffraction or ESZ techniques for PM from animal feeding operations with large mass median diameters (MMDs) and geometric standard deviations (GSDs); (2) compare mass fractions of PM 10 and PM 2.5 between the measured values and the lognormal fitting values derived from the measured MMDs and GSDs. For future relevant studies, it is recommended that limitations of PSD measurements by a given method should be recognized and measured PM 10 and PM 2.5 mass fraction should be simultaneously reported when reporting a MMD and a GSD for apsdmeasurement. 2. Material and methods 2.1. Particle size analyzers The particle size analyzers for the study include (1) a LS multi-wave length laser diffraction particle size analyzer (Beckman Coulter Inc., Miami, FL) owned by the Research Group at North Carolina State University (NCSU); (2) a LA300 laser scattering particle size analyzer (Horiba Instruments Inc., Irvine, CA) owned by the Research Group at University of Illinois at Urbana- Champaign (UIUC); (3) a Coulter Counter Multisizer3, CCM3 (Beckman Coulter Inc., Miami, FL) owned by the Center for Agricultural Air Quality Engineering and Science at Texas A&M University (TAMU); (4) a Coulter Counter Multisizer3, CCM3 (Beckman Coulter Inc., Miami, FL) and a LS230 laser diffraction particle size analyzer (Beckman Coulter Inc., Miami, FL) owned by the research group at USDA-ARS Cotton Production and Processing Research Unit in Lubbock, TX, hereby also known as USDA.

3 L. Wang-Li et al. / Atmospheric Environment 66 (2013) 25e32 27 Since the selection of refractive index is critical for the light scattering analyzers, a preliminary investigation was conducted for unknown refractive index of the PM samples taken from the animal house. The final selection of the refractive index was 1.34 for LA300 at UIUC (swine PM-based), and 1.5 for LS at NCSU (organic matter based). The PSDs measured by all these the analyzers were volume distributions in ESD. Since the U.S. EPA regulates PM by mass in two size ranges (10 mm, or 2.5 mm) in the form of AED, measured PSDs by volume in ESD were then converted to PSDs in AED using the following equation (Hinds, 1999): rffiffiffiffiffi r AED ¼ ESD P (1) c Where r p is the particle density, measured by a pycnometer (AccuPyc1330, Micromeritics, Norcross, GA), c is the shape factor of a particle and was assumed to be 1 in this study (Cao, 2009). It was assumed that densities of particles in different sizes of the same kind PM were the same; hence the volume-based PSD was considered as the mass-based PSD. The volumetric median diameters were treated as MMD Field PM sample collection and sample allocation Samples of total suspended particulate (TSP) were collected using six low-volume (LV) TSP samplers (Wang-Li et al., 2013). This LV-TSP sampler was originally designed and manufactured by the research group at Texas A&M University following the EPA s specifications of the engineering design parameters for a high volume TSP sampler in 40 CFR Part 50 Appendix B (1987). Detailed design and performance of the sampler were reported in Wangjura et al. (2005). The field PM sampling was conducted in a high-rise tunnelventilated egg production (layer) house. The detailed information about the farm and the layer houses is reported in Wang-Li et al. (submitted for publication). In brief, the sampling house has dimensions of 175 m long by 18 m wide with approximately 95,000 laying hens. In this high-rise house, laying hens were housed in the upper floor (referred to as 2nd floor). Manure fell into the pit (referred to as 1st floor). Ventilation air entered the 2nd floor of the house through 36.5 m long air inlets centered on two side walls of the house. Each endwall was equipped with seventeen, 1.2-m (48- in) diameter, 480 VAC, 3-phase, belt-driven ventilation fans (Choretime). Among these seventeen fans, eight fans were located in the 2nd floor, and nine fans were in the 1st floor. Each house had 34 fans in total, and was ventilated in 11 stages. Three (3) LV-TSP samplers were co-located on the first floor and the other three LV-TSP samplers were co-located on the second floor of the same house immediately upstream of the exhaust fans on the east endwall. The placement of the TSP samplers is illustrated in Fig. 1 and more detailed information about the PM sampling is reported in Wang-Li et al. (2013). The co-located sampling design generated three replicates in TSP samples on each floor for each sampling event. Thirteen (13) sampling events were carried out through 4 consecutive days in winter of 2008e2009, spring of 2009, respectively. Thus, each season produced 78 samples in total. After sampling, the three sample replicates on each floor were randomly selected and distributed to three research groups having different instruments at three locations. For each season, 26 samples were allocated for each of the three locations. The PM samples assigned to NCSU, UIUC and TAMU or USDA were analyzed for PSDs in terms of MMDs and GSDs by LS13 320, LA300, CCM3 and LS230 particle size analyzers Filter-based PM sample extraction To measure PSDs of the PM sample collected on the TSP filters, 47 mm (2.5 mm) ZefluorÔ supported PTFE filters (Pall Corporation, Ann Arbor, Michigan), it is required to extract PM from the filters and disperse them into a solvent that could be introduced into the analyzers for PSD analysis. When selecting a suitable solvent as a dispersant for the PM samples, properties of the samples (i.e., solubility, reactivity, and suspendibility) governed the choice of the medium. Through a chemical speciation analysis study, it was discovered that the PM in the egg production houses was organic in nature mainly generated from chicken manure and feed (Li, 2012), and formation of secondary inorganic PM was insignificant due to very short residence time of pollutant gases in the animal houses and lack of acid gases to react with NH 3 (Li, 2012). To minimize soluble loss, the organic solvent, ethanol was used as the PM sample extraction medium. For laser diffraction analyzers, the PM samples were extracted from filters into ethanol using ultrasonic bath method; whereas for Coulter Counter Multisizer, the PM samples were extracted from filters into electrolyte solution, a 5% lithium chloride/methanol solution. A preliminary study on determining optimum ultrasonic time was conducted to obtain the best sample extraction and dispersion without particle breakdown (Cao, 2009). It was discovered that fifteen minutes was the time when the most coagulated particles were separated and yet no break-down of the particles was observed. As a result, all the PM samples were extracted through ultrasonic bath for 15 min. Fig. 1. Placement of the LV-TSP samplers inside the high-rise layer house. [A]: Three LV-TSP samplers collocated on the 1st floor; [B]: Three LV-TSP samplers on the 2nd floor.

4 Testing powders for laboratory comparisons In order to further investigate the difference in PSDs measured by different instruments, four types of testing aerosols were used to reduce the measurement uncertainty possibly caused by field sampling and/or sample extraction at three different locations (NCSU, UIUC and USDA). These four types of testing aerosols include limestone, starch, No.3 micro aluminum, and No.5 micro aluminum. These testing aerosols were prepared using the same operation procedure before they were analyzed by the different analyzers. The testing aerosol samples were analyzed for PSDs in terms of MMDs and GSDs by LS at NCSU, LA300 at UIUC, and CCM3 and LS230 at USDA, respectively Data analysis Cumulative lognormal distribution forms of PSDs The lognormal distribution is the most commonly used PSD model (Hinds, 1999). Typically, a lognormal distribution describing a PSD in mass is characterized by a MMD and a GSD. By definition, MMD is the particle size where 50% of PM mass is larger or smaller than this diameter. The GSD is defined as the ratio of particle sizes corresponding to cumulative mass fraction of 84.1% and 50%, or 50% and 15.9%, or the square root of the ratio of 84.1% and 15.9% (Hinds, 1999). The mathematical expression of a fractional PSD is as following: " 1 df ¼ p ffiffiffiffiffiffi 2p *dp *lnðgsdþ exp lndp lnðmmdþ # 2 2ðlnðGSDÞÞ 2 dd p (2) The PSD can also be described as a cumulative distribution F a, which gives the mass fraction of all the particles with diameters less than a, thus F 10 ¼ PM 10 and F 2.5 ¼ PM 2.5. The cumulative distribution function is presented as: F a ¼ Z a 0 " 1 p ffiffiffiffiffiffi 2p *dp *lnðgsdþ exp lndp lnðmmdþ # 2 2ðlnðGSDÞÞ 2 dd p ¼ F d p ; MMD; GSD (3) Comparisons of PM 10 and PM 2.5 mass fractions: lognormal fitting values vs. measured values As indicators for PM in the National Ambient Air Quality Standards (NAAQS), mass fractions of the PM 10 and PM 2.5 are usually of interests. When a PSD was measured by an analyzer, the mass fractions of PM 10 and PM 2.5 were also measured by the instrument. In the literature, the PSD has often been reported by MMD and GSD assuming that a PSD followed a lognormal distribution. Based upon the measured MMD and GSD, the mass fractions of PM 10 and PM 2.5 may be calculated using cumulative lognormal distribution function (Equation (2)). These calculated PM 10 and PM 2.5 mass fraction are hereby defined as lognormalfitting values. The lognormal-fitting values of PM 10 and PM 2.5 are most probably what could be cited by other researchers if only measured MMD and GSD were reported. It is expected that the measured & the fitting values of PM 10 or PM 2.5 agree only if a PSD follows the lognormal distribution well. To investigate possible errors associated with the lognormal fitting method for PM 10 and PM 2.5 mass fraction determination, the relative differences (RDs) between the measured and the fitting values were defined for comparison: L. Wang-Li et al. / Atmospheric Environment 66 (2013) 25e32 Lognormal Measured RD ¼ 100% (4) Measured Where, Measured is the mass fraction of PM 10 or PM 2.5 measured by the analyzer; Lognormal is the mass fraction of PM 10 or PM 2.5 calculated using the lognormal distribution formula (Equation (3)) with measured MMD and GSD Statistic tests For comparisons of measured PSDs by the different analyzers for field samples taken in winter and spring, or for testing powders samples, single factor ANOVA tests were performance to compare mean MMDs and PSDs. TukeyeKramer test, a multiple comparison procedure was also applied to further check whether measured MMDs and GSDs from different instruments were significantly different from each other. In addition, paired-t tests were conducted on means to identify significant difference between two means. 3. Results and discussion 3.1. PSDs of the field PM samples Since it is not feasible to report all the original PSD measurement curves for all the 156 field samples (78 samples per season for two seasons), one set of measured fractional PSD curves by the different analyzers is illustrated in Fig. 2 as an example. Figs. 3 and 4 show the comparisons of the cumulative PSD curves by the different analyzers for the field TSP samples. These PSD curves were constructed using Equation (2) and the measured mean MMDs and mean GSDs listed in Tables 1 and 2. The statistic tests (ANOVA and TukeyeKramer tests) suggest that there were significant difference in MMDs (p < ) and GSDs (p < ) obtained by these three instruments. In general, LA-300 at UIUC provided the largest MMDs; whereas CCM3 at TAMU gave the smallest MMDs. LS provided the largest GSDs; whereas CCM3 gave the smallest GSDs. As it may be observed in Fig. 2, the size measurement ranges of the analyzers were different. While the laser diffraction analyzers provided large size ranges (0.04e 2000 mm for LS13 320; 0.1e600 mm for LA300), ESZ analyzer, i.e. the CCM3 with 100 mm aperture provided a measurement range in 2.95e60 mm. The differences in size measurement ranges is suspected to be the major source causing measurement difference between light scattering method and ESZ methods for this study. In comparison to the literature, the observation of smaller MMD and GSD measurements by the ESZ method (CCM3) as compared to the laser diffraction method is in agreement with the findings by Jerez et al. (2011) in a study of PSDs of the PM samples taken from a swine building. There was no significant difference in MMDs (p ¼ 0.400) and GSDs (p ¼ 0.297) between LS at NCSU and LS230 at USDA. Significant differences in MMDs (p < ) and GSDs (p < ) from between LS and LA-300 were observed. Using different refractive indices is suspected to be one cause of different PSD measurement results. In addition, LA300 is a laser scattering instrument with much simpler optics and fitting algorithm, compared with LS13 320, although both of these two instruments are laser diffraction particle size analyzers. If there are small peaks in the PSD, LA300 may not be able to detect. As shown in Fig. 5, there were some small peaks missed by the LA300 when compared with the LS13302 s measurement. The MMDs obtained by LA-300 were larger than that measured by LS13 320, whereas GSDs obtained by LA-300 were smaller than that measured by LS for all PM samples. These differences may be considered as

5 L. Wang-Li et al. / Atmospheric Environment 66 (2013) 25e32 29 systematic error due to different characteristics of these two laser diffraction particle size analyzers PSDs of the testing powder samples Figs. 6e9 show the comparisons of the cumulative PSD curves by the different analyzers for the testing powder samples, i.e. limestone, starch, No.3 micro aluminum and No.5 micro aluminum. The measured mean MMDs and GSDs by the different analyzers are listed in Table 3. There was significant difference in MMDs obtained from LA-300 at UIUC and the other three instruments (LS13 320, LS230 and CCM3). Two laser diffraction type analyzers (LS at Fig. 2. (continued). Fig. 3. Comparison of the cumulative PSD curves by the different analyzers for the winter PM samples (Note: the PSD curves were constructed using Equation (2) and the measured mean MMDs and mean GSDs in Table 1). Fig. 2. Illustration of the measured PSD curves by the different analyzers for the field PM samples. Fig. 4. Comparison of the cumulative PSD curves by the different analyzers for spring PM samples (Note: the PSD curves were constructed using Equation (2) and the measured mean MMDs and mean GSDs in Table 2).

6 30 L. Wang-Li et al. / Atmospheric Environment 66 (2013) 25e32 Table 1 Summary of the MMDs (mm) and GSDs measured by the three analyzers for winter samples. PSD a NCSU UIUC TAMU LS LA-300 CCM3 MMD (mean SD) GSD (mean SD) a Mean MMDs and GSDs are the average values of replicates of 26 PM samples. Table 2 Summary of the MMDs (mm) and GSDs measured by the three analyzers for spring samples. PSD a NCUS UIUC USDA LS LA-300 LS230 CCM3 MMD (mean SD) GSD (mean SD) b Mean MMDs and GSDs are average values of replicates of 26 PM samples. Fig. 6. Comparison of the cumulative PSD curves by the different analyzers for limestone samples (Note: the PSD curves were constructed using Equation (2) and the measured mean MMDs and mean GSDs in Table 3). NCSU and LS230 at USDA) provided very similar results for MMDs. In general, LA-300 provided larger MMDs than the other three instruments. No significant difference in MMDs among the other three instruments (LS13 320, LS230 and CCM) was observed. Differences in GSDs obtained from different instruments were observed. In general, laser diffraction series particle size analyzers (LS at NCSU and LS230 at USDA) provided quite similar GSDs. Small but consistent difference in GSDs was observed between CCM3 at USDA and LA-300 at UIUC. However, significant Fig. 7. Comparisons of the cumulative PSD curves by the different analyzers for starch samples (Note: the PSD curves were constructed using Equation (2) and the measured mean MMDs and mean GSDs in Table 3). Fig. 5. Measured PSD curves for the limestone sample by the two light-scattering analyzers. Fig. 8. Comparisons of the cumulative PSD curves by the different analyzers for No.3 aluminum samples (Note: the PSD curves were constructed using Equation (2) and the measured mean MMDs and mean GSDs in Table 3).

7 L. Wang-Li et al. / Atmospheric Environment 66 (2013) 25e32 31 Fig. 9. Comparisons of the cumulative PSD curves by the different analyzers for No.5 aluminum samples (Note: the PSD curves were constructed using Equation (2) and the measured mean MMDs and mean GSDs in Table 3). Table 3 Summary of PSDs a of the testing aerosols measured by the four analyzers. Testing aerosols LS LA-300 LS230 CCM3 MMD (mm) GSD MMD (mm) GSD MMD (mm) GSD MMD (mm) GSD Limestone Starch No.3 micro aluminum No.5 micro aluminum Average a MMDs and GSDs are average values of three replicates. differences in GSDs were observed between LS series and CCM3. In general, LS series provided larger GSDs than CCM3 and LA-300. A T-test was performed on the data to further determine if there were significant differences in MMDs and GSDs measured by four different instruments. The differences in MMD measurements by LS at NCSU and LA-300 at UIUC were significant (p ¼ 0.014), but the GSDs were not (p ¼ 0.079) at the 0.05 level of significance (a). No significant differences in MMDs and GSDs of PSDs were detected between LS at NCSU, LS230 at USDA and CCM3 at USDA. The comparative PSD results of testing powder samples measured by the different instruments were generally consistent with that of the filter-based samples (field samples). Differences in PSDs for both filter-based samples and testing powders measured by the four different instruments at four different locations (LS at NCSU, LA-300 at UIUC, CCM3 at TAMU, CCM3 and LS230 at USDA) are statistically significant. In general, LA-300 provided the largest MMDs and LS230 gave the largest GSDs; the smallest MMDs and GSDs were provided by LS and CCM3, respectively. LS230 and LS provided very similar results for both MMDs and GSDs. Both of LS and CCM3 were produced by Beckman Coulter Inc. Xu and Guida (2003) reported that laser diffraction provided much larger MMDs and broader distributions (GSDs) than the ESZ. In this study, LS provided larger MMDs and GSDs than CCM3, which is consistent with Xu and Guida s report. These differences may be systematic errors due to different principles that these two instruments rely on, and different size measurement range. Specifically, the laser diffraction particle size analyzer (e.g. LS13 320, LS230, LA300) applies aerosol optical property for size measurements. As it is well known, element carbon is a light absorber, whereas organics, sulfates, nitrates and soil are light scatters. Therefore, PM chemical compositions have substantially impact on LS13 320/LS230/LA300, but not on CCM3. On the other hand, the Coulter Counter particle sizer (e.g. CCM3) operates on the electrical resistance principle and uses an apparatus to count and size particles suspended in electrolytes. Irregular shapes and conductivity of the particles passing through the aperture would have substantial impact on measurements. Knowing the chemical and physical properties of PM being studied is essential for selection of an appropriate PSD analyzer Mass fractions of PM 10 and PM 2.5 : measured values vs. lognormal-fitting values The mean mass fractions of PM 10 and PM 2.5 obtained from measurements of PSDs by the different analyzers and from lognormal-fitting values using the measured MMD and GSDs of the corresponding PSD measurements are summarized in Table 4. When examining the PM 10 mass fractions, no significant difference was observed between lognormal-fitting values and the measured values. The mean (SD) of the RDs for PM 10 were in range of 0.39% (0.80%) to 3.34% (5.34%). The lognormal method produced reasonably accurate estimation of PM 10 mass fraction. On the other hand, as shown in Table 4, lognormal-fitting method generated significant smaller PM 2.5 mass fractions than the measured fractions by the different analyzers (laser diffraction or ESZ method) for all the samples. This might be due to the fact that the mass fraction of PM 2.5 is considerably away from medium mass (2.5 mm << MMD). This observation suggests that the PSDs of the PM samples did not follow lognormal distributions. The means (SD) of the RDs for PM 2.5 were in range of 54.96% (13.04%) to 94.46% (3.05%). The significant differences between the measured PM 2.5 mass fraction and the lognormal fitting PM 2.5 mass fraction suggest that the lognormal method cannot produce accurate estimation of PM 2.5 mass fraction although the measured MMD and GSD were used. It is strongly recommended that when Table 4 Summary of the measured and the lognormal-fitting mass fractions of PM 10 and PM 2.5 and the RDs. Location Model PM 10 fraction (%) (measured) PM 10 fraction (%) (lognormal) RD (%) PM 2.5 fraction (%) (measured) PM 2.5 fraction (%) (lognormal) NCSU a LS UIUC a LA TAMU b CCM e d e e USDA c CCM LS a The means are the average values of the replicates of 52 PM samples collected in winter and spring. b The means are the average values of the replicates of 26 PM samples collected in winter. c The means are the average values of the replicates of 26 PM samples collected in spring. d No PM 2.5 measurements. RD (%)

8 32 L. Wang-Li et al. / Atmospheric Environment 66 (2013) 25e32 reporting a PSD of certain PM samples, in addition to MMD and GSD, the mass fractions of PM 10 and PM 2.5 should also be reported. 4. Conclusions This study investigated PSD measurement differences by four commonly used analyzers: LS multi-wave length laser diffraction particle size analyzer, LS230 laser diffraction particle size analyzer, LA-300 laser scattering particle size analyzer, and Coulter Counter Multisizer3 (CCM3). It was discovered that there were significant differences in MMDs and GSDs measurements by the laser diffraction analyzers and the ESZ (Coulter Counter Multisizers) for the PM samples collected in the layer house and for the testing powder samples. The laser diffraction method (LS13 320, LS230 and LA-300) provided much larger MMDs and broader distributions (GSDs) than the ESZ (CCM3). Since the selection of refractive index is critical for the light scattering analyzers, unknown of reflective index for poultry PM is suspected to be a major source of error for the laser diffraction particle size analyzers. In addition, the differences in size measurement ranges is suspected to be another major source causing measurement difference between light scattering method and ESZ method. Different characteristics of principles may also be reasons causing measurement difference. For future relevant studies, it is recommended that limitations of PSD measurements by a given method should be recognized. This study also revealed that when comparing mass fractions of PM 10 between the measured values and the lognormal fitting values derived from the measured MMDs and GSDs, the lognormal fitting method produced reasonably accurate PM 10 mass fraction estimations (within 5%), but it failed to produce accurate PM 2.5 mass fraction estimations for PM samples taken from a poultry house. The mean differences between measured PM 2.5 and lognormal-fitting PM 2.5 were in range of 54.96% (13.04%)e94.46% (3.05%). It is strongly recommended that when reporting a PSD of certain PM sample, in addition to MMD and GSD, the mass fractions of PM 10 and PM 2.5 should also be reported. While the findings of this study provide better understanding of the limitations in PSD measurements by the light scattering technique and electric sensing zone method for PM sources with large MMD and GSD (i.e. PM emitted from animal feeding operations), further investigation is needed to identify most accurate measurement method through comparison of the studied methods with a standard method when the standard becomes available. Acknowledgments This study was supported in part by USDA NRI Grant No and NSF CAREER Award No. CBET Help from Zifei Liu and Qianfeng Li for the field TSP sampling is also acknowledged. A special thank-you goes to the egg production farm for the support. References Cao, Z., Determination of Particle Size Distribution of Particulate Matter Emitted from a Layer Operation in Southeast U.S. M.S. thesis. North Carolina State University, Department of Biological and Agricultural Engineering, Raleigh, NC. Code of Federal Regulations, 40CFR, Part 50-Appendix B, Reference Method for the Determination of Suspended Particulate Matter in the Atmosphere (High-volume Method). Hinds, W.C., Aerosol Technology. Properties, Behavior, and Measurement of Airborne Particles, second ed. John Wiley and Sons, New York. Jerez, S.B., Zhang, Y., Wang, X., Measurement of particle size distribution in a swine building. Trans. ASABE 54 (3), 1103e1117. Lines, R.W., Knapp, J.Z., Barber, T.A., Lieberman, A., Dekker, M. (Eds.), The Electrical Sensing Zone Method in Liquid and Surface-borne Particle Measurement Handbook, New York, (Chapter 4), pp. 113e154. Li, Q.-F., Particulate Matter from an Egg Production Facility: Emission, Chemistry and Local Dispersion. Ph.D. diss. North Carolina State University, Department of Biological and Agricultural Engineering, Raleigh, NC. McClure, J., Determination of Particulate Emissions from Confined Animal Housing. Ph.D. dissertation. University of Illinois at Urbana-Champaign, Urbana, IL. Mitchell, J.P., Nagel, M.W., Time-of-flight aerodynamic particle size analyzers: their use and limitations for the evaluation of medical aerosols. J. Aerosol Medicine-Deposition Clearance and Effects in the Lung 12 (4), 217e240. Parker, J.-M., Rock, J.C., Wang, L., Seo, Y.-C., Bhtnagar, A., Performance evaluation of six different aerosol samplers in a particulate matter generation chamber. Atmos. Environ. 43, 280e289. Peters, T.M., Leith, D., Concentration measurement and counting efficiency of the aerodynamic particle sizer J. Aerosol Sci. 34 (5), 627e634. Smyth, H.D., Hickey, A.J., Multimodal particle size distributions emitted from HFA-134a solution pressurized metered dose inhalers. AAPS Pharm. Sci. Technol. 4, E38. Wangjura, J.D., Parnell, C.B., Shaw, B.W., Lacey, R.E., Design and evaluation of low-volume total suspended particulate sampler. Trans. ASABE 48 (4), 1547e1552. Wang-Li, L., Li, Q.F., Wang, K., Bogan, B.W., Ni, J.-Q., Cortus, E.L., Heber, A.J. National air emission monitoring study-southeast layer site: part I-site specifics and monitoring methodology. Trans. ASABE, submitted for publication. Wang-Li, L., Cao, Z., Li, Q.-F., Liu, Z., Beasley, D.B., Concentration and particle size distribution of particulate matter inside tunnel-ventilated high-rise layer operation houses. Atmos. Environ. 66, 8e16. Xu, R.L., Guida, O.A., Comparison of sizing small particles using different technologies. Power Technol. 132, 145e153. Ziegler, J., Wachtel, H., Comparison of cascade impaction and laser diffraction for particle size distribution measurements. J. Aerosol Med. 18, 311e324.

Effect of Air Density on Cyclone Performance and System Design

Effect of Air Density on Cyclone Performance and System Design Paper Number: 024216 An ASAE Meeting Presentation Effect of Air Density on Cyclone Performance and System Design Lingjuan Wang, Graduate Research Assistant Department of Biological and Agricultural Engineering

More information

Multiple Series Cyclones for Fine Dust

Multiple Series Cyclones for Fine Dust An ASAE Meeting Presentation Paper Number: 054014 Multiple Series Cyclones for Fine Dust D.P. Whitelock, Agricultural Engineer USDA-ARS Southwestern Cotton Ginning Research Laboratory, dwhitelo@nmsu.edu

More information

EFFECT OF AIR DENSITY ON CYCLONE PERFORMANCE AND SYSTEM DESIGN

EFFECT OF AIR DENSITY ON CYCLONE PERFORMANCE AND SYSTEM DESIGN EFFECT OF AIR DENSITY ON CYCLONE PERFORMANCE AND SYSTEM DESIGN L. Wang, M. D. Buser, C. B. Parnell, B. W. Shaw ABSTRACT. 1D3D and 2D2D cyclones were tested at Amarillo, Texas, to evaluate the effect of

More information

STUDY OF DESIGN OF CYCLONE SEPARATOR UNDER COLLECTION EFFICIENCY AND AIR DENSITY EFFECT

STUDY OF DESIGN OF CYCLONE SEPARATOR UNDER COLLECTION EFFICIENCY AND AIR DENSITY EFFECT STUDY OF DESIGN OF CYCLONE SEPARATOR UNDER COLLECTION EFFICIENCY AND AIR DENSITY EFFECT Radhe Shyam Verma 1, Prakash Kumar Sen 2, Shailendra Kumar Bohidar 3 1 Student, Mechanical Engineering, Kirodimal

More information

Estimation of Mass with the Model 3321 APS Spectrometer

Estimation of Mass with the Model 3321 APS Spectrometer Particle Sizers Estimation of Mass with the Model 3321 APS Spectrometer Application Note APS-001 Introduction Particle size and mass are two important parameters that are often used to characterize an

More information

International publications on measuring nanoparticles with the portable testo DiSCmini particle counter.

International publications on measuring nanoparticles with the portable testo DiSCmini particle counter. Testo Book of Abstracts International publications on measuring nanoparticles with the portable testo DiSCmini particle counter. www.testo-particle.com testo DiSCmini Great insights into the world of the

More information

Traceability research activities in the field of airborne particle number/ mass concentration measurement Liu Junjie, Zhang Wenge, Song Xiaoping

Traceability research activities in the field of airborne particle number/ mass concentration measurement Liu Junjie, Zhang Wenge, Song Xiaoping Traceability research activities in the field of airborne particle number/ mass concentration measurement Liu Junjie, Zhang Wenge, Song Xiaoping Division of Nano metrology and Materials Measurement National

More information

Calibration checks of particle counter using primary and other techniques at the laboratory level

Calibration checks of particle counter using primary and other techniques at the laboratory level Calibration checks of particle counter using primary and other techniques at the laboratory level Shankar G. Aggarwal, Ph.D. CSIR-National Physical Laboratory, New Delhi-110 012, India @ Particulate Workshop

More information

Rapid Measurements of Aerosol Size Distributions Using a Fast Integrated Mobility Spectrometer (FIMS)

Rapid Measurements of Aerosol Size Distributions Using a Fast Integrated Mobility Spectrometer (FIMS) Rapid Measurements of Aerosol Size Distributions Using a Fast Integrated Mobility Spectrometer (FIMS) Jason Olfert, Brookhaven National Laboratory Jian Wang, Brookhaven National Laboratory Measurement

More information

DUST SETTLING USING A NEGATIVE IONIZATION SYSTEM

DUST SETTLING USING A NEGATIVE IONIZATION SYSTEM DUST SETTLING USING A NEGATIVE IONIZATION SYSTEM Dust Settling using a Negative Ionization System in a Confinement Swine Building Akihiro Tanaka, Yuanhui Zhang SUMMARY Dust is one of the main contaminants

More information

PARTICLE SIZE ANALYTICAL RANGES AND APPLICABILITY. m mm (10-6 m) nm (10-9 m)

PARTICLE SIZE ANALYTICAL RANGES AND APPLICABILITY. m mm (10-6 m) nm (10-9 m) P A R T I C L E S I Z E A N A L Y S I S PARTICLE SIZE Accurately determining particle size has become essential in many industries, as it is a fundamental physical characteristic that must be selected,

More information

Nanoparticle Exposure in the Workplace

Nanoparticle Exposure in the Workplace Nanoparticle Exposure in the Workplace Michele. L. Ostraat, Ph.D. RTI International September 11, 2012 Practical Workplace Issues Related to Setting & Using Engineered Nanomaterial OELs Lack of instrumentation/characterization

More information

Ultra Sonic Sprayer Controlling Dust in Experimental Poultry Houses

Ultra Sonic Sprayer Controlling Dust in Experimental Poultry Houses 1 Ultra Sonic Sprayer Controlling Dust in Experimental Poultry Houses Atsuo Ikeguchi Lab. of Animal Husbandry Engineering, Dept. of Feeding and Environment, National Institute of Animal Industry, Japan

More information

Continuous measurement of airborne particles and gases

Continuous measurement of airborne particles and gases Continuous measurement of airborne particles and gases Jeff Collett and Taehyoung Lee Atmospheric Science Department Colorado State University Funding: USDA/AES and NPS Outline Why measure particles and

More information

ATOC 3500/CHEM 3152 Week 9, March 8, 2016

ATOC 3500/CHEM 3152 Week 9, March 8, 2016 ATOC 3500/CHEM 3152 Week 9, March 8, 2016 Hand back Midterm Exams (average = 84) Interaction of atmospheric constituents with light Haze and Visibility Aerosol formation processes (more detail) Haze and

More information

429 LIGHT DIFFRACTION MEASUREMENT OF PARTICLE SIZE

429 LIGHT DIFFRACTION MEASUREMENT OF PARTICLE SIZE Search USP29 429 LIGHT DIFFRACTION MEASUREMENT OF PARTICLE SIZE Light diffraction is one of the most widely used techniques for measuring the size of a wide range of particles from very fine to very coarse.

More information

IMPACT OF PARTICLE AGGREGATED MICROBES AND PARTICLE SCATTERING ON UV DISINFECTION

IMPACT OF PARTICLE AGGREGATED MICROBES AND PARTICLE SCATTERING ON UV DISINFECTION IMPACT OF PARTICLE AGGREGATED MICROBES AND PARTICLE SCATTERING ON UV DISINFECTION Hadas Mamane-Gravetz and Karl G. Linden Duke University Department of Civil and Environmental Engineering Box 90287 Durham,

More information

Meetprincipes voor meting van nanodeeltjes in de lucht

Meetprincipes voor meting van nanodeeltjes in de lucht Meetprincipes voor meting van nanodeeltjes in de lucht Andreas Schmidt-Ott Nanostructured Materials, Faculty of Applied Sciences, TU Delft Qauntum dots van verschillende afmetingen geven licht in verschillende

More information

Introduction to Open-Path Transmissometry as a Surrogate Measure of Ambient PM at Cattle Feedyards

Introduction to Open-Path Transmissometry as a Surrogate Measure of Ambient PM at Cattle Feedyards Introduction to Open-Path Transmissometry as a Surrogate Measure of Ambient PM at Cattle Feedyards Brent Auvermann, Naruki Hiranuma, Kevin Heflin and Gary Marek Texas A&M University System Amarillo/Canyon,

More information

MEASURING NANOPARTICLE EXPOSURE

MEASURING NANOPARTICLE EXPOSURE MEASURING NANOPARTICLE EXPOSURE APPLICATION NOTE NSAM-001 The Nanoparticle Surface Area Monitor reports the surface area of inhaled particles deposited in the lung Nanoparticle Exposure There is increasing

More information

The Elzone II Particle Count and Size Analyzer

The Elzone II Particle Count and Size Analyzer The Elzone II 5390 Particle Count and Size Analyzer Elzone II Overview of Basic Theory Operates using the Electrical Sensing Zone (ESZ) Principle, also known as the Coulter Principle. First commercially

More information

Decay of Rotational Airflow with Flow Conditioner in Larger Diameter Ducts for Dust Concentration Measurement using Isokinetic Sampling

Decay of Rotational Airflow with Flow Conditioner in Larger Diameter Ducts for Dust Concentration Measurement using Isokinetic Sampling 1 Decay of Rotational Airflow with Flow Conditioner in Larger Diameter Ducts for Dust Concentration Measurement using Isokinetic Sampling Z. C. Tan, Y. Zhang, S. E. Ford Department of Agricultural and

More information

ASSESSMENT OF SUSPENDED DUST FROM PIPE RATTLING OPERATIONS

ASSESSMENT OF SUSPENDED DUST FROM PIPE RATTLING OPERATIONS ASSESSMENT OF SUSPENDED DUST FROM PIPE RATTLING OPERATIONS A Dissertation by JU-MYON PARK Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements

More information

Comprehensive Measurement of Atmospheric Aerosols with a Wide Range Aerosol Spectrometer

Comprehensive Measurement of Atmospheric Aerosols with a Wide Range Aerosol Spectrometer Comprehensive Measurement of Atmospheric Aerosols with a Wide Range Aerosol Spectrometer Juergen Spielvogel, Lothar Keck, Xiaoai Guo, Markus Pesch Email: jsp@grimm-aerosol.com GRIMM Aerosol Technik GmbH

More information

Fundamentals of Particle Counting

Fundamentals of Particle Counting Fundamentals of Particle Counting 1 Particle Counting: Remains the most significant technique for determining the cleanliness level of a fluid Useful as a tool for qualification and monitoring cleanroom

More information

Standardisation of Particulate and Aerosol Measurements. Hanspeter Andres

Standardisation of Particulate and Aerosol Measurements. Hanspeter Andres Standardisation of Particulate and Aerosol Measurements Hanspeter Andres Agenda 1. Particulates in Aerosols 2. Measures for Particulates in Aerosols 3. Traceability routes 4. International comparability

More information

The new 11-R (one part of the Mini WRAS) and GRIMM MINI-WRAS Andreas Jaksch. Symposium Stockholm Mai

The new 11-R (one part of the Mini WRAS) and GRIMM MINI-WRAS Andreas Jaksch. Symposium Stockholm Mai The new 11-R (one part of the Mini WRAS) and GRIMM MINI-WRAS Andreas Jaksch Symposium Stockholm Mai 2014 1 Outline Optical Particle Detection Method 11-R Main features of the GRIMM 11-R Measurement principle

More information

White Rose Research Online URL for this paper: Version: Accepted Version

White Rose Research Online URL for this paper:  Version: Accepted Version This is a repository copy of A comparison of the sampling efficiency of bioaerosol samplers and particle counters in natural and controlled environments. White Rose Research Online URL for this paper:

More information

Particle size analysis -Chapter 3

Particle size analysis -Chapter 3 Particle size analysis -Chapter 3 Importance of PSA Size and hence surface area of particles affect: The rate of drug dissolution and release from dosage forms Flow properties of granules and powders.

More information

GRIMM Aerosol Spectrometer and Dust Monitors. Measuring principle

GRIMM Aerosol Spectrometer and Dust Monitors. Measuring principle Grimm Aerosol-Technik GRIMM Aerosol Spectrometer and Dust Monitors Measuring principle Eng. Wolfgang Brunnhuber 1 Agenda Part A physical background general principles of optical particle detection Part

More information

Engineered Nanomaterials and Occupational Health

Engineered Nanomaterials and Occupational Health Engineered Nanomaterials and Occupational Health Andrew D. Maynard Chief Science Advisor Society of Toxicology, National Area Chapter. Novemb er 2nd 2005, Washington DC Woodrow Wilson Center, Project on

More information

Differential Mobility Particle Sizer (Aerosol measurements)

Differential Mobility Particle Sizer (Aerosol measurements) Institute for Atmospheric and Climate Science - IACETH Atmospheric Physics Lab Work Differential Mobility Particle Sizer (Aerosol measurements) Abstract A differential mobility particle sizer (DMPS) is

More information

Advanced technique to reduce emissions of fine particulate matter using ultrasounds

Advanced technique to reduce emissions of fine particulate matter using ultrasounds Sustainable Chemistry 61 Advanced technique to reduce emissions of fine particulate matter using ultrasounds B. Bergmans 1, M. Dormann 2, F. Idczak 1, S. Petitjean 1, D. Steyls 2 & B. Vanderheyden 2 1

More information

ARTICLE IN PRESS. Journal of Aerosol Science

ARTICLE IN PRESS. Journal of Aerosol Science Journal of Aerosol Science 41 (2010) 99 107 Contents lists available at ScienceDirect Journal of Aerosol Science journal homepage: www.elsevier.com/locate/jaerosci Use of proton backscattering to determine

More information

Comparing Modal and Sectional Approaches in Modeling Particulate Matter in Northern California

Comparing Modal and Sectional Approaches in Modeling Particulate Matter in Northern California Comparing Modal and Sectional Approaches in Modeling Particulate Matter in Northern California K. Max Zhang* [1], Jinyou Liang [2], Anthony S. Wexler [1], and Ajith Kaduwela [1,2] 1. University of California,

More information

Supplementary Material

Supplementary Material Supplementary Material Description of the Sensitivity Analysis of The Model To test the performance of the model we tested the effect of the input-parameters on the output of the model. The analysis was

More information

Pharmaceutical Particulate Matter

Pharmaceutical Particulate Matter Pharmaceutical Particulate Matter Analysis and Control Thomas A. Barber Baxter Healthcare Illustrations by John G. Williams Photomicrography Section by Damian S. Neuberger Interpharm Press Buffalo Grove,

More information

Review of the IMPROVE Equation for Estimating Ambient Light Extinction

Review of the IMPROVE Equation for Estimating Ambient Light Extinction Review of the IMPROVE Equation for Estimating Ambient Light Extinction Jenny Hand 1 Bill Malm 2 1 CIRA, Colorado State University 2 National Park Service OUTLINE Introduction Sampling Biases Chemical forms

More information

Improvement of traceability in the field of mass concentration measurements of particles in aerodisperse media carried out in the Russian Federation

Improvement of traceability in the field of mass concentration measurements of particles in aerodisperse media carried out in the Russian Federation International Bureau of Weights and Measures Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology Working Group on Gas Analysis PARTICULATE WORKSHOP Improvement of traceability

More information

Elimination of dust production from stables for dairy cows

Elimination of dust production from stables for dairy cows Czech J. Anim. Sci., 51, 2006 (7): 305 310 Original Paper Elimination of dust production from stables for dairy cows J. Dolejš, O. Mašata, O. Toufar Research Institute of Animal Production, Prague-Uhříněves,

More information

58 Guinan St. Waltham, MA Ph.: Fx.: E mail:

58 Guinan St. Waltham, MA Ph.: Fx.: E mail: BGI Incorporated 58 Guinan St. Waltham, MA 02451 Ph.: 781 891 9380 Fx.: 781 891 8151 E mail: bsk29@attglobal.net www.bgiusa.com Technical Report: Evaluation of a Sharp Cut Cyclone for PM 1 Sampling January

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 21501-2 First edition 2007-05-15 Determination of particle size distribution Single particle light interaction methods Part 2: Light scattering liquid-borne particle counter

More information

Urban background aerosols: Negative correlations of particle modes and fragmentation mechanism

Urban background aerosols: Negative correlations of particle modes and fragmentation mechanism Click Here for Full Article GEOPHYSICAL RESEARCH LETTERS, VOL. 34, L11811, doi:10.1029/2006gl029109, 2007 Urban background aerosols: Negative correlations of particle modes and fragmentation mechanism

More information

BGI Incorporated. 58 Guinan St. Waltham, MA Ph.: Fx.: E mail:

BGI Incorporated. 58 Guinan St. Waltham, MA Ph.: Fx.: E mail: BGI Incorporated 58 Guinan St. Waltham, MA 02451 Ph.: 781 891 9380 Fx.: 781 891 8151 E mail: bsk29@attglobal.net www.bgiusa.com Technical Report: Evaluation of SCC and GK Type Personal Cyclones March 2000

More information

Particle size and shape distribution of stable dust analysed with laser diffraction and imaging technique

Particle size and shape distribution of stable dust analysed with laser diffraction and imaging technique M. Romann et al. / Landbauforschung Völkenrode Special Issue 38 91 Particle size and shape distribution of stable dust analysed with laser diffraction and imaging technique M. Romann 1 and T. Hinz 2 Abstract

More information

Swine Enteric Coronavirus Disease (SECD) Situation Report June 30, 2016

Swine Enteric Coronavirus Disease (SECD) Situation Report June 30, 2016 Animal and Plant Health Inspection Service Veterinary Services Swine Enteric Coronavirus Disease (SECD) Situation Report June 30, 2016 Information current as of 12:00 pm MDT, 06/29/2016 This report provides

More information

Jianfei Peng et al. Correspondence to: Jianfei Peng Min Hu and Renyi Zhang

Jianfei Peng et al. Correspondence to: Jianfei Peng Min Hu and Renyi Zhang Supplement of Atmos. Chem. Phys., 17, 10333 10348, 2017 https://doi.org/10.5194/acp-17-10333-2017-supplement Author(s) 2017. This work is distributed under the Creative Commons Attribution 3.0 License.

More information

C H A P T E R 5 ENVIRONMENTAL PROTECTION AGENCY. APTI 413: Control of Particulate Matter Emissions. Student Manual Chapter 5.

C H A P T E R 5 ENVIRONMENTAL PROTECTION AGENCY. APTI 413: Control of Particulate Matter Emissions. Student Manual Chapter 5. Chapter 5 C H A P T E R 5 ENVIRONMENTAL PROTECTION AGENCY APTI 413: Control of Particulate Matter Emissions Student Manual Chapter 5 C H A P T E R 5 A P T I : 4 1 3 C O N T R O L O F P A R T I C U L A

More information

Who is polluting the Columbia River Gorge?

Who is polluting the Columbia River Gorge? Who is polluting the Columbia River Gorge? Final report to the Yakima Nation Prepared by: Dan Jaffe, Ph.D Northwest Air Quality, Inc. 7746 Ravenna Avenue NE Seattle WA 98115 NW_airquality@hotmail.com December

More information

Introduction and Initial Field Data of a Novel, Portable Nanoparticle Sizing Instrument

Introduction and Initial Field Data of a Novel, Portable Nanoparticle Sizing Instrument Introduction and Initial Field Data of a Novel, Portable Nanoparticle Sizing Instrument Torsten Tritscher 1, Thomas J. Krinke 1, Axel F. Zerrath 2, Erik Willis 2 and Oliver F. Bischof 1 1 TSI GmbH, Particle

More information

Comparison of AERONET inverted size distributions to measured distributions from the Aerodyne Aerosol Mass Spectrometer

Comparison of AERONET inverted size distributions to measured distributions from the Aerodyne Aerosol Mass Spectrometer Comparison of inverted size distributions to measured distributions from the Aerodyne Aerosol Mass Spectrometer Peter DeCarlo Remote Sensing Project April 28, 23 Introduction The comparison of direct in-situ

More information

Swine Enteric Coronavirus Disease (SECD) Situation Report Mar 5, 2015

Swine Enteric Coronavirus Disease (SECD) Situation Report Mar 5, 2015 Animal and Plant Health Inspection Service Veterinary Services Swine Enteric Coronavirus Disease (SECD) Situation Report Mar 5, 2015 Information current as of 12:00 pm MDT, 03/04/2015 This report provides

More information

Glossary of Common Laboratory Terms

Glossary of Common Laboratory Terms Accuracy A measure of how close a measured value is to the true value. Assessed by means of percent recovery of spikes and standards. Aerobic Atmospheric or dissolved oxygen is available. Aliquot A measured

More information

Analysis of Data from the 2009 SOOT Experiment

Analysis of Data from the 2009 SOOT Experiment Analysis of Data from the 2009 SOOT Experiment Renyi Zhang Department of Atmospheric Sciences and Department of Chemistry Center for Atmospheric Chemistry and the Environment Texas A&M University College

More information

An assessment of time changes of the health risk of PM10 based on GRIMM analyzer data and respiratory deposition model

An assessment of time changes of the health risk of PM10 based on GRIMM analyzer data and respiratory deposition model J. Keder / Landbauforschung Völkenrode Special Issue 38 57 An assessment of time changes of the health risk of PM based on GRIMM analyzer data and respiratory deposition model J. Keder Abstract PM particles

More information

Performance Characterization of A New Cam System M.J. Koskelo 1, J.C. Rodgers 2, D.C. Nelson 2, A.R. McFarland 3 and C.A. Ortiz 3

Performance Characterization of A New Cam System M.J. Koskelo 1, J.C. Rodgers 2, D.C. Nelson 2, A.R. McFarland 3 and C.A. Ortiz 3 Performance Characterization of A New Cam System M.J. Koskelo 1, J.C. Rodgers 2, D.C. Nelson 2, A.R. McFarland 3 and C.A. Ortiz 3 1 CANBERRA Industries, Meriden, CT 06450 2 Los Alamos National Laboratory,

More information

Aerosol Optical Properties

Aerosol Optical Properties ATM 507 Lecture 25 Text reading Chapter 15 Paper Due Dec. 9 Review Session Dec. 9 Final Dec. 12 (10:30 AM-12:30 PM) Today s topic Aerosol Optical Properties 1 Aerosol Optical Properties There are a number

More information

Big Bend Regional Aerosol & Visibility Observational Study

Big Bend Regional Aerosol & Visibility Observational Study Big Bend Regional Aerosol & Visibility Observational Study BRAVO - Results Bret Schichtel National Park Service, Schichtel@cira.colostate.edu Presented at the BRAVO Public Meeting Alpine, Texas September

More information

MODULE 4.3 Atmospheric analysis of particulates

MODULE 4.3 Atmospheric analysis of particulates MODULE 4.3 Atmospheric analysis of particulates Measurement And Characterisation Of The Particulate Content 1 Total particulate concentration 1 Composition of the particulate 1 Determination of particle

More information

Haze Communication using the CAMNET and IMPROVE Archives: Case Study at Acadia National Park

Haze Communication using the CAMNET and IMPROVE Archives: Case Study at Acadia National Park Haze Communication using the CAMNET and IMPROVE Archives: Case Study at Acadia National Park Light absorption by fine Light scattering by fine Clear line of sight in absence of fine Light extinction is

More information

Regional Haze Metrics Trends and HYSPLIT Trajectory Analyses. May 2017

Regional Haze Metrics Trends and HYSPLIT Trajectory Analyses. May 2017 Regional Haze Metrics Trends and HYSPLIT Trajectory Analyses May 2017 Principal Contributors: Tom Downs, CCM, ME DEP Project manager Martha Webster, ME DEP Trajectory analyses and GIS mapping Rich Greves,

More information

Measurement of Particle Size Distributions

Measurement of Particle Size Distributions Measurement of Particle Size Distributions Static Laser Scattering perfect for Particle Size Measurement in the Range of 0.01 2000 µm Particle size measurement with state of the art laser technology: simple

More information

Chemical mass closure of atmospheric aerosol collected over Athens, Greece.

Chemical mass closure of atmospheric aerosol collected over Athens, Greece. Chemical mass closure of atmospheric aerosol collected over Athens, Greece. Paraskevopoulou D. 1, 2, Liakakou E. 1, Theodosi C. 2, Zarmpas P. 2, Gerasopoulos E. 1 1, 2*, Mihalopoulos N. 1 Institute for

More information

Swine Enteric Coronavirus Disease (SECD) Situation Report Sept 17, 2015

Swine Enteric Coronavirus Disease (SECD) Situation Report Sept 17, 2015 Animal and Plant Health Inspection Service Veterinary Services Swine Enteric Coronavirus Disease (SECD) Situation Report Sept 17, 2015 Information current as of 12:00 pm MDT, 09/16/2015 This report provides

More information

VALIDATION STUDY OF FTIR-BASED EMISSIONS MEASUREMENTS AT A MUNICIPAL WASTE COMBUSTOR

VALIDATION STUDY OF FTIR-BASED EMISSIONS MEASUREMENTS AT A MUNICIPAL WASTE COMBUSTOR AP-157 VALIDATION STUDY OF FTIR-BASED EMISSIONS MEASUREMENTS AT A MUNICIPAL WASTE COMBUSTOR Grant M. Plummer, Ph.D. Peter Zemek, Ph.D. Special Projects Manager Applications Manager Enthalpy Analytical,

More information

Particuology 9 (2011) Contents lists available at SciVerse ScienceDirect. Particuology. j o ur nal homep ag e:

Particuology 9 (2011) Contents lists available at SciVerse ScienceDirect. Particuology. j o ur nal homep ag e: Particuology 9 (2011) 606 610 Contents lists available at SciVerse ScienceDirect Particuology j o ur nal homep ag e: www.elsevier.com/locate/partic Evaluation of particle growth systems for sampling and

More information

Generation of monodisperse aerosols through condensation nuclei control

Generation of monodisperse aerosols through condensation nuclei control Air Pollution XV 505 Generation of monodisperse aerosols through condensation nuclei control H. M. Kadlimatti 1, S. Gangamma 2 & S. K. Varghese 3 1 Department of Mechanical Engineering, Basaveshwar Engineering

More information

Lecture 26. Regional radiative effects due to anthropogenic aerosols. Part 2. Haze and visibility.

Lecture 26. Regional radiative effects due to anthropogenic aerosols. Part 2. Haze and visibility. Lecture 26. Regional radiative effects due to anthropogenic aerosols. Part 2. Haze and visibility. Objectives: 1. Attenuation of atmospheric radiation by particulates. 2. Haze and Visibility. Readings:

More information

Design of experiments and empirical models for up to date burners design for process industries

Design of experiments and empirical models for up to date burners design for process industries Design of experiments and empirical models for up to date burners design for process industries Proceedings of European Congress of Chemical Engineering (ECCE-6) Copenhagen, 16-20 September 2007 Design

More information

Study of "Baffle Type Pre-separator Plus Cyclone" Abatement Systems for Cotton Gins

Study of Baffle Type Pre-separator Plus Cyclone Abatement Systems for Cotton Gins An ASAE/CSAE Meeting Presentation Paper Number: 044017 Study of "Baffle Type Pre-separator Plus Cyclone" Abatement Systems for Cotton Gins Lingjuan Wang, Ph.D., Postdoctoral Research Associate John D.

More information

ISO INTERNATIONAL STANDARD. Particle size analysis Laser diffraction methods. Analyse granulométrique Méthodes par diffraction laser

ISO INTERNATIONAL STANDARD. Particle size analysis Laser diffraction methods. Analyse granulométrique Méthodes par diffraction laser INTERNATIONAL STANDARD ISO 13320 First edition 2009-10-01 Particle size analysis Laser diffraction methods Analyse granulométrique Méthodes par diffraction laser Reference number ISO 13320:2009(E) ISO

More information

Responses of Low Pressure Andersen Sampler for Collecting Substrates

Responses of Low Pressure Andersen Sampler for Collecting Substrates Responses of Low Pressure Andersen Sampler for Collecting Substrates K.Yamasaki 1, Y.Yamada 2, K.Miyamoto 2 and M.Shimo 2 1 Research Reactor Institute, Kyoto University Noda, Kumatori-cho, Sennan-gun,

More information

Latest Technology and Standardization Trends for Liquid-borne Particle Counters

Latest Technology and Standardization Trends for Liquid-borne Particle Counters Latest Technology and Standardization Trends for Liquid-borne Particle Counters Kaoru Kondo Rion Co., Ltd. (Original paper is K.Kondo, Bunseki,Vol.9, p499 (2012)) Abstract Fine particles contaminating

More information

Draft PS 18 APPENDIX A Dynamic Spiking Procedure ( ) 1.1 This appendix to Performance Specification 18

Draft PS 18 APPENDIX A Dynamic Spiking Procedure ( ) 1.1 This appendix to Performance Specification 18 Draft PS 18 APPENDIX A Dynamic Spiking Procedure (4-4-2013) A1. Scope and Application 1.1 This appendix to Performance Specification 18 describes the procedure and performance requirements for dynamic

More information

Chasing Aerosol Particles Down to Nano Sizes

Chasing Aerosol Particles Down to Nano Sizes Chasing Aerosol Particles Down to Nano Sizes ERC Seminar 13 June 2013 Armin Sorooshian Chemical & Environmental Engineering Atmospheric Sciences University of Arizona Outline of Talk 1. What are aerosol

More information

Process Development & Scale-Up of the AIR Technology

Process Development & Scale-Up of the AIR Technology Process Development & Scale-Up of the AIR Technology Lloyd Johnston, Ph.D. Vice President of Process Development & Manufacturing October 6, 2005 Pharmaceutical Industry o Delivering needed therapeutics

More information

GAW - WCCAP recommendation for aerosol inlets and sampling tubes

GAW - WCCAP recommendation for aerosol inlets and sampling tubes GAW - WCCAP recommendation for aerosol inlets and sampling tubes Alfred Wiedensohler, Wolfram Birmili, Leibniz Institute for Tropospheric Research, Leipzig, Germany John Ogren, NOAA ESRL GMD, Boulder,

More information

University of Pécs Institute of Pharmaceutical Technology and Biopharmacy

University of Pécs Institute of Pharmaceutical Technology and Biopharmacy University of Pécs Institute of Pharmaceutical Technology and Biopharmacy Particle Definition In a continuous phase the particle is an (mostly in gaseous or liquid material) existing, dispersed, interface

More information

Determination of particle size distribution Single particle light interaction methods. Part 4:

Determination of particle size distribution Single particle light interaction methods. Part 4: Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 21501-4 Second edition 2018-05 Determination of particle size distribution Single particle light interaction methods Part 4: Light scattering airborne

More information

OPTIMAL WAVELENGTH SELECTION ALGORITHM OF NON-SPHERICAL PARTICLE SIZE DISTRIBUTION BASED ON THE LIGHT EXTINCTION DATA

OPTIMAL WAVELENGTH SELECTION ALGORITHM OF NON-SPHERICAL PARTICLE SIZE DISTRIBUTION BASED ON THE LIGHT EXTINCTION DATA THERMAL SCIENCE, Year 2012, Vol. 16, No. 5, pp. 1353-1357 1353 OPTIMAL WAVELENGTH SELECTION ALGORITHM OF NON-SPHERICAL PARTICLE SIZE ISTRIBUTION BASE ON THE LIGHT EXTINCTION ATA by Hong TANG * College

More information

Appendix A - Test Methods Method 301--Field Validation of Pollutant Measurement Methods from Various Waste Media

Appendix A - Test Methods Method 301--Field Validation of Pollutant Measurement Methods from Various Waste Media Appendix A - Test Methods Method 301--Field Validation of Pollutant Measurement Methods from Various Waste Media 1. APPLICABILITY AND PRINCIPLE 1.1 Applicability. This method, as specified in the applicable

More information

APPLICABILITY OF A PORTABLE PARTICLE MONITOR FOR MEASURING TSP AND PM10 IN THE AMBIENT ENVIRONMENT. A Thesis MINGQI ZOU

APPLICABILITY OF A PORTABLE PARTICLE MONITOR FOR MEASURING TSP AND PM10 IN THE AMBIENT ENVIRONMENT. A Thesis MINGQI ZOU APPLICABILITY OF A PORTABLE PARTICLE MONITOR FOR MEASURING TSP AND PM10 IN THE AMBIENT ENVIRONMENT A Thesis by MINGQI ZOU Submitted to the Office of Graduate and Professional Studies of Texas A&M University

More information

Department of Energy Office of Worker Protection Programs and Hazards Management Radiological Control Technical Position RCTP 99-02

Department of Energy Office of Worker Protection Programs and Hazards Management Radiological Control Technical Position RCTP 99-02 Issue: Title 10 Code of Federal Regulations, Part 835 (10 CFR 835), Occupational Radiation Protection, specifies occupational radiation protection requirements for Department of Energy (DOE) activities

More information

Physics Experimental Physics Temple University, Spring C. J. Martoff, Instructor

Physics Experimental Physics Temple University, Spring C. J. Martoff, Instructor Physics 4796 - Experimental Physics Temple University, Spring 2010-11 C. J. Martoff, Instructor Physics 4796 Lab Writeup Counting Statistics (or, Is it Radioactive?) 0.1 Purpose of This Lab Exercise: Demonstrate

More information

ENVR 116 Aerosol Technology Laboratory Session Fall 2005

ENVR 116 Aerosol Technology Laboratory Session Fall 2005 ENVR 116 Aerosol Technology Laboratory Session Fall 2005 INSTRUMENT CALIBRATION USING PSL SPHERES The objective of this lab is to become familiar with the operation, characteristics, and limitations of

More information

The Coulter Principle for Outlier Detection in Highly Concentrated Solutions

The Coulter Principle for Outlier Detection in Highly Concentrated Solutions The Coulter Principle for Outlier Detection in Highly Concentrated Solutions Particle Characterization Application Note Abstract This application note will benefit chemical and material manufacturers concerned

More information

ITS. One of the highest resolutions for particle sizing and counting. Multisizer 3 COULTER COUNTER SCIENCE

ITS. One of the highest resolutions for particle sizing and counting. Multisizer 3 COULTER COUNTER SCIENCE ITS SCIENCE ITS SCIENCE Sp. z o.o. Sp. K. Poświętne 25B, 26-670 Pionki +48 48 612 71 65 www.itsscience.pl One of the highest resolutions for particle sizing and counting. Multisizer 3 COULTER COUNTER Blood

More information

An analytical model for the fractional efficiency of a uniflow cyclone with a tangential inlet

An analytical model for the fractional efficiency of a uniflow cyclone with a tangential inlet Available online at www.sciencedirect.com Powder Technology 83 (2008) 47 5 www.elsevier.com/locate/powtec An analytical model for the fractional efficiency of a uniflow cyclone with a tangential inlet

More information

Phys Biomedical Physics: Yong-qing Li, PhD. Department of Physics, East Carolina University Greenville, NC 27858, USA.

Phys Biomedical Physics: Yong-qing Li, PhD. Department of Physics, East Carolina University Greenville, NC 27858, USA. Phys 6715 - Biomedical Physics: Optical Trapping in Air Yong-qing Li, PhD Department of Physics, East Carolina University Greenville, NC 27858, USA Email: liy@ecu.edu 1 Outline 1. Why optical trapping

More information

Chapter Eight: Conclusions and Future Work

Chapter Eight: Conclusions and Future Work 2004 PhD Thesis 202 Chapter Eight: Conclusions and Future Work 8.1 Conclusions The Aerodyne aerosol mass spectrometer is capable of providing quantitative information on the chemical composition of the

More information

Author(s) Affiliation. Author(s)

Author(s) Affiliation. Author(s) Send your completed paper to Sandy Rutter at rutter@asae.org by 15 May 2005 to be included in the meeting CD-ROM. fter the meeting, papers will also be included in the SE Online Technical Library. If you

More information

Reactive Nitrogen Monitoring

Reactive Nitrogen Monitoring Reactive Nitrogen Monitoring Some definitions NOy NO + NO 2 + NO 3 + 2xN2 2 O 5 + HNO 3 + HONO + HO 2 NO 2 + RONO 2 (organic nitrates such as PAN and alkyl nitrates) + RONO (organic nitrites) + NO 3 -

More information

ITRS, SEMI and ASTM Guidelines for Semiconductor Ultrapure Water (UPW) Production and the Consequences for UPW Particle Metrology

ITRS, SEMI and ASTM Guidelines for Semiconductor Ultrapure Water (UPW) Production and the Consequences for UPW Particle Metrology ITRS, SEMI and ASTM Guidelines for Semiconductor Ultrapure Water (UPW) Production and the Consequences for UPW Particle Metrology David Blackford, Ph.D. Fluid Measurement Technologies, Inc. St. Paul, Minnesota

More information

USING CYCLONES EFFECTIVELY AT COTTON GINS

USING CYCLONES EFFECTIVELY AT COTTON GINS USING CYCLONES EFFECTIVELY AT COTTON GINS D. P. Whitelock, C. B. Armijo, M. D. Buser, S. E. Hughs ABSTRACT. Cyclones are the most common type of emissions control device used in agricultural processing

More information

ENVE 576 Indoor Air Pollution Fall 2015

ENVE 576 Indoor Air Pollution Fall 2015 ENVE 576 Indoor Air Pollution Fall 2015 Week 11: November 3, 2015 1. SVOCs 2. Aerosol sampling techniques Dr. Brent Stephens, Ph.D. Department of Civil, Architectural and Environmental Engineering Illinois

More information

EP-SAW for Measurement of Atmospheric Particulate Matter

EP-SAW for Measurement of Atmospheric Particulate Matter EP-SAW for Measurement of Atmospheric Particulate Matter M. I. Newton, C. J. Percival, S. M. Stanley and G. McHale Department of Chemistry and Physics The Nottingham Trent University Nottingham NG11 8NS,

More information

Optical properties of atmospheric constituents

Optical properties of atmospheric constituents Optical properties of atmospheric constituents Direct effects of aerosols optical properties on climate Scattering Aerosols Absorbing Aerosols heat heat heat heat heat Cooling Clouds evaporation Graphics:

More information

Characterisation of nanomaterials for REACH dossiers - best practice 30 October 2012

Characterisation of nanomaterials for REACH dossiers - best practice 30 October 2012 Characterisation of nanomaterials for REACH dossiers - best practice 30 October 2012 Abdelqader Sumrein Evaluation Directorate ECHA Outline Nanomaterials under REACH: reflections from 2010 registrations

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 21501-4 First edition 2007-05-15 Determination of particle size distribution Single particle light interaction methods Part 4: Light scattering airborne particle counter for

More information

Sensors - April A Certified-Emissivity Blackbody for Calibrating Infrared Thermometers

Sensors - April A Certified-Emissivity Blackbody for Calibrating Infrared Thermometers Page 1 of 9 www.sensorsmag.com APRIL 2002 SENSOR TECHNOLOGY AND DESIGN A Certified-Emissivity Blackbody for Calibrating Infrared Thermometers As a practical matter, most commercial infrared thermometers

More information