next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

Size: px
Start display at page:

Download "next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size"

Transcription

1 Particle size Welcome to the next generation Your sample, expertly processed and prepared Dispersion options 3000 detailed specification sheets from

2 Getting your sample preparation right The US Pharmacopeia provides a helpful summary of what a sample preparation unit for laser diffraction must provide: A representative sample, dispersed at an adequate concentration in a suitable liquid or gas * Sounds simple doesn t it? But with the Mastersizer 3000 specified for the measurement of very many materials, from coarse granulates to finely dispersed emulsions, no single sample dispersion technique or unit is universally applicable. So, Malvern has created a range of accessories to ensure reproducible sample preparation, in line with ISO13320:2009 and pharmacopeia requirements. *General Chapter 429, Light Diffraction Measurement of Particle Size. United States Pharmacopeia. Wet or dry... For wet dispersion, we have the Hydro family of products. Aero is the dry dispersion engine. Designed from the ground up, Aero redefines what a dry dispersion unit can do. All are controlled in real-time via the analyzer software. Auto-locking measurement cells, coupled with automated system initialization, streamlines the switch from one to another. The result is fast, efficient, well-controlled dispersion, whatever the sample. Flexible, independent operation for any user. 2

3 Back to basics - Wet dispersion Wet dispersion is the most common choice for particle size measurement. Essential for slurries and emulsions, it is also used in the analysis of fine, friable and fragile powders. Wet dispersion is more gentle than dry, enabling de-agglomeration without primary particle break-up, for even the most delicate of materials. The process of dispersion using liquids involves wetting each individual particle to ensure agglomerate separation. Dispersant choice and the use of sonication are important for success, while stabilizers may also be used to prevent re-agglomeration. From measurement cell To measurement cell Stirrer In-line ultrasound probe Centrifugal pump Dispersant pump Drain Rely on our experience Malvern s sample preparation accessories build on the experience and know-how that comes from having delivered more than 10,000 Mastersizer systems.the Hydro family is a range of compact units which span a variety of dispersant volumes. They meet the need for the larger sample volumes often required to representatively measure highly polydisperse materials, as well as the smaller volumes preferred when measuring high-value materials, especially during product development. Hydro units in the ml dispersant range benefit from in-line sonication for more efficient dispersion, and powerful centrifugal pumps that prevent sedimentation. Wetted surfaces are chemically compatible with a wide choice of dispersants. The automatic delivery of organic and inorganic dispersants allows for close matching with application requirements. 3

4 The established leaders in wet dispersion Hydro LV The Hydro LV is a large volume dispersion unit, designed to achieve precise, automated dispersion in applications where sample availability is not an issue. Ideal for the measurement of higher density materials and broad size distributions, the system achieves agglomerate dispersal thought the use of in-line sonication, rapidly achieving reproducible dispersion and reproducible results. 600ml dispersant volume Powerful centrifugal pump system ensures bias-free sampling 35W in-line sonication probe, for rapid agglomerate dispersion Automated dispersant supply Full software control of all measurement functions, including dispersant supply, sample dispersion and cleaning Full chemical compatibility Hydro EV Using Malvern s unique dip-in sample dispersion head, the Hydro EV achieves full, rapid dispersion of samples in a standard laboratory beaker. Able to operate with a range of dispersant volumes, its efficient design ensures representative sampling across a wide range of particle sizes. Following measurement, the dispersion head can be raised out of the beaker, enabling quick cleaning and sample recovery. Compatible with 250ml, 600ml and 1000ml laboratory beakers Dip-in centrifugal pump and stirrer design 35W in-line sonication probe, for rapid agglomerate dispersion Software control of pump/stirrer and sonication Sample easily recovered following analysis Full chemical compatibility 4

5 Hydro MV The Hydro MV is an automated, smaller volume dispersion unit, enabling the measurement of a wide range of materials in both aqueous and non-aqueous liquids. Designed for applications where material is in short supply, or where dispersant use must be minimized, it ensures reproducible dispersion for smaller sample sizes. This makes it ideal for use during early stage product development, or for the dispersion of samples which are water-soluble ml dispersant volume 35W in-line sonication probe, for rapid agglomerate dispersion Powerful centrifugal pump system ensures bias-free sampling Precise software control of all measurement functions, including dispersant supply, sample dispersion and cleaning Full chemical compatibility 5

6 Enjoy the advantages of dry dispersion Dry dispersion is fast and avoids the use of dispersants. The best method for suitable dry samples, it is especially important when particle size is influenced by hydration, for certain foodstuffs, pharmaceuticals, coatings and building materials, for example. Collision Collision Velocity gradients caused by shear stress Particle-to-particle collisions Particle-to-wall collisions Mechanisms for dry dispersion. Representative measurement relies on providing sufficient energy to break up agglomerates without causing primary particle damage. Dry powder dispersers accelerate particles in an airstream to achieve this. New thinking Aero is a brand new dispersion engine, designed from the ground up using the latest dispersion theory. Capable of applying significant shear, it has no impaction surfaces. As a result Aero achieves complete and robust dispersion, even for friable and fragile particles, without inflicting particle damage. Aero extends the range of applicability for dry measurement. Three parameters are used to control dry dispersion: sample feed rate; disperser geometry; and air pressure. Advantage Aero Interchangeable geometries match the requirements of different sample types Air pressure dictates the amount of energy applied during dispersion, increasing pressure increasing the intensity of dispersion Sample feed rate can be precisely manipulated to control measurement concentration and ensure that sufficient data is recorded to reproducibly quantify the sample With a data acquisition rate of 10kHz, Mastersizer 3000 measures accurately at relatively fast feed rates, accelerating analysis 6

7 Aero S the new standard Achieving rapid, reproducible aerodynamic dispersion of dry powders, the Aero S dry powder disperser extends the range of applications for dry dispersion by providing a modular platform which is easily configured for different applications. Dispersion is achieved by accelerating particles through a venturi using compressed air. The availability of different disperser designs enables the system to measure friable materials and robust samples equally well, across an extremely wide size range ( μm). Precise control of the sample feed rate and the applied dispersion pressure ensure the Aero system delivers the most reproducible results possible. Put simply, Aero is the world s most capable dry powder disperser Standard dispersers for both cohesive and fragile particle measurements Impaction systems available for robust material dispersion Precise dispersion pressure control, to 0.1 bar precision Range of sample feed trays and hoppers enable measurement of different sample sizes Enclosed cell delivers bias-free measurements whilst minimising user exposure to the sample Full software control of all measurement functions, including sample feed and dispersion 7

8 Accessory Specifications Wet Analysis Hydro MV Hydro LV Hydro EV Pump speed range * rpm rpm rpm Pump speed resolution +/-10 rpm +/-10 rpm +/-10 rpm Pump speed accuracy +/-50 rpm +/-50 rpm +/-50 rpm Maximum flow rate * 2.3 l/m 2.3 l/min 1.7 l/min Sonication power / frequency * 35W max, 40kHz (nominal) 35W max, 40kHz (nominal) 35W max, 40kHz (nominal) Maximum volume 120ml 600ml 250ml/600ml/1000ml (using lab beaker) 316 stainless Borosilicate Glass Tygon 316 stainless Borosilicate Glass Tygon 316 stainless Borosilicate Glass Tygon Materials in contact with sample Viton (cell seal only - Viton (cell seal only - Viton (cell seal only - perlast upgrade available) perlast upgrade available) perlast upgrade available) PTFE PEEK FEP PTFE PEEK FEP PTFE PEEK FEP Maximum particle size ** 2100µm (density 2100kg/m 3 ) 2100µm (density 2100kg/m 3 ) 2100µm (density 2100kg/m 3 ) Minimum time between measurements ** less than 60 sec less than 60 sec less than 60 sec Dimensions (LxWxH) 280mm x 180mm x 300mm 280mm x 180mm x 300mm 220mm x 150mm x 300mm Mass 5kg 5kg 4kg Dry Analysis Aero S Dispersion Pressure Range 0 4 bar Pressure setting precision +/-0.1 bar Pressure setting accuracy +/-0.03 bar Feed rate range 0 6g (expressed as 0 100%) Feed rate precision +/-0.06g (1%) Feed rate accuracy Better than 1% 410 hardened stainless Polyurethane Materials in contact with sample Borosilicate Glass Carbon Filled Acetal EPDM Aluminium PTFE Neoprene Maximum particle size ** 3500µm (density 2200kg/m 3 ) Minimum time between measurements ** less than 60 sec Dimensions (LxWxH) 260mm x 180mm x 380mm Mass Power Product storage conditions Operational conditions Regulatory testing IP Rating Computer Specification (recommended) Notes 10.5kg Accessory Systems Compliance (all units) Accessory Systems Compliance Powered via Mastersizer 3000 optics unit -20 C to +50 C, 10% 80% RH (non-condensing) +10 C to +35 C, 10% 80% RH (non-condensing) RoHS and WEEE compliant ICES / CE / C-Tick / FCC / VCCI compliant Meets requirements of the European Low Voltage directive IP41D in use As per Mastersizer 3000 optics unit * Dispersant dependent ** Sample dependant Sample dependant Malvern Instruments Limited Grovewood Road Malvern Worcestershire UK WR14 1XZ Tel: +44 (0) Fax: +44 (0) Malvern Instruments Worldwide Sales and service centres in over 50 countries. For details visit distributor details 3000 All information supplied is correct at time of publication. Malvern, Mastersizer and the hills logo are international Trade Marks owned by Malvern Instruments Ltd. detailed specifications at Copyright 2011, Malvern Instruments Ltd. All rights reserved. MRK Malvern Instruments has a policy of continuous improvement and specifications may change. Malvern Instruments is part of Spectris plc, the Precision Instrumentation and Controls Company.

MASTERSIZER 3000 SMARTER PARTICLE SIZING

MASTERSIZER 3000 SMARTER PARTICLE SIZING MASTERSIZER 3000 SMARTER PARTICLE SIZING MASTERSIZER 3000 WELCOME TO THE NEXT GENERATION Rapid, reliable particle size measurements made easy. The Mastersizer 3000 is the latest generation of the world

More information

MASTERSIZER 3000 SMARTER PARTICLE SIZING

MASTERSIZER 3000 SMARTER PARTICLE SIZING MASTERSIZER 3000 SMARTER PARTICLE SIZING MASTERSIZER 3000 WELCOME TO THE NEXT GENERATION Rapid, reliable particle size measurements made easy. The Mastersizer 3000 is the latest generation of the world

More information

MASTERSIZER 3000 SMARTER PARTICLE SIZING

MASTERSIZER 3000 SMARTER PARTICLE SIZING MASTERSIZER 3000 SMARTER PARTICLE SIZING MASTERSIZER 3000 WELCOME TO THE NEXT GENERATION Rapid, reliable particle size measurements made easy. The Mastersizer 3000 is the latest generation of the world

More information

ZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight

ZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight Particle size Zeta potential Molecular weight ZS90 The ultimate in desktop particle characterization detailed specifications from www.malvern.com/zetasizernano A routine analysis system for particle characterization

More information

Inform is a series of white papers designed to provide advice on material characterization issues. Mie theory The rst 100 years

Inform is a series of white papers designed to provide advice on material characterization issues. Mie theory The rst 100 years Inform is a series of white papers designed to provide advice on material characterization issues Mie theory The rst 100 years Mie theory the rst 100 years One hundred years ago Gustav Mie developed an

More information

10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS

10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS 10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS Abstract: New components and measurement techniques continue to be introduced for the Zetasizer Nano. New to the system are a Surface

More information

The ultimate in desktop particle characterization

The ultimate in desktop particle characterization Particle size Zeta potential Molecular weight ZS The ultimate in desktop particle characterization detailed specification from www.malvern.com/zetasizernano The Zetasizer Nano ZS brings you the practicality

More information

Overcoming and quantifying Wall Slip in measurements made on a rotational rheometer

Overcoming and quantifying Wall Slip in measurements made on a rotational rheometer Overcoming and quantifying Wall Slip in measurements made on a rotational rheometer RHEOLOGY AND VISCOSITY Introduction When making shear rheological measurements on structured liquids, in particular suspensions,

More information

Determining cure profile and post-cure shrinkage of photopolymers using UV accessory on a rotational rheometer

Determining cure profile and post-cure shrinkage of photopolymers using UV accessory on a rotational rheometer Determining cure profile and post-cure shrinkage of photopolymers using UV accessory on a rotational rheometer RHEOLOGY AND VISCOSITY Introduction A photopolymer usually consists of monomers, oligomers

More information

The ultimate in desktop particle characterization

The ultimate in desktop particle characterization Particle size Zeta potential Molecular weight ZS The ultimate in desktop particle characterization detailed specification from www.malvern.com/zetasizernano The Zetasizer Nano ZS brings you the practicality

More information

Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS)

Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS) Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS) CHEMICAL IDENTIFICATION PARTICLE SIZE PARTICLE SHAPE Introduction Interest in studying mixed

More information

Component specific particle characterisation of the active components in a pharmaceutical topical formulations

Component specific particle characterisation of the active components in a pharmaceutical topical formulations Component specific particle characterisation of the active components in a pharmaceutical topical formulations PARTICLE SIZE PARTICLE SHAPE CHEMICAL IDENTIFICATION Introduction Most pharmaceutical products

More information

Method validation for laser diffraction measurements

Method validation for laser diffraction measurements Method validation for laser diffraction measurements Introduction When undertaking particle size measurements it is important to validate the analysis method to ascertain both its robustness and integrity.

More information

Using rheology to study the hardness and spreadability of butter

Using rheology to study the hardness and spreadability of butter Using rheology to study the hardness and spreadability of butter RHEOLOGY AND VISCOSITY Introduction Butter is a multiphase emulsion consisting of fat globules, crystalline fat and an aqueous phase dispersed

More information

KINEXUS DSR SERIES REDEFINING RHEOMETER CAPABILITIES FOR ASPHALT TESTING

KINEXUS DSR SERIES REDEFINING RHEOMETER CAPABILITIES FOR ASPHALT TESTING KINEXUS DSR SERIES REDEFINING RHEOMETER CAPABILITIES FOR ASPHALT TESTING ASPHALT CHARACTERIZATION AND CLASSIFICATION TO ASPHALT INDUSTRY STANDARDS Asphalt, or bitumen, is a petroleum product used in the

More information

REVERSE ENGINEERING PHARMACEUTICAL FORMULATION USING THE MORPHOLOGI G3-ID.

REVERSE ENGINEERING PHARMACEUTICAL FORMULATION USING THE MORPHOLOGI G3-ID. REVERSE ENGINEERING PHARMACEUTICAL FORMULATION USING THE MORPHOLOGI G3-ID. Introduction According to the definition established by the FDA, a generic drug is a drug product which is comparable to a reference

More information

Bohlin. Rheological instruments backed with rheological experience. Rheological properties

Bohlin. Rheological instruments backed with rheological experience. Rheological properties Rheological properties ṙ Bohlin Rheological instruments backed with rheological experience detailed specification sheets from /bohlingemini The Bohlin Gemini rheometers are an advanced range of compact

More information

GPC/SEC Analysis of Polymer Degradation

GPC/SEC Analysis of Polymer Degradation MOLECULAR WEIGHT Introduction MOLECULAR Understanding the effects of processing a polymer on its molecular weight, STRUCTURE molecular weight distribution, and solution viscosity are important to MOLECULAR

More information

Nanobubble Applications and Characterization by Nanoparticle Tracking Analysis

Nanobubble Applications and Characterization by Nanoparticle Tracking Analysis Nanobubble Applications and Characterization by Nanoparticle Tracking Analysis Review of ultra-fine bubble (nanobubble) applications and characterization examples PARTICLE CONCENTRATION PARTICLE SIZE Introduction

More information

Your partner in Science!

Your partner in Science! Your partner in Science! Your partner in Science! Laser Diffraction Particle Size Distribution Analyzer LA-960 Simple, Powerful, Reliable 10 nm - 5 mm The LA-960 features intuitive software, unique accessories,

More information

Evaluating the rheological properties of hyaluronic acid hydrogels for dermal filler applications

Evaluating the rheological properties of hyaluronic acid hydrogels for dermal filler applications Evaluating the rheological properties of hyaluronic acid hydrogels for dermal filler applications RHEOLOGY AND VISCOSITY PARTICLE SIZE Introduction Hyaluronic acid (HA) is a naturally occurring polysaccharide

More information

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements Optimization of PLA/PLGA molecular weight and structure to suit final application requirements MOLECULAR SIZE MOLECULAR STRUCTURE MOLECULAR WEIGHT Introduction The biodegradable and biocompatible polymers,

More information

Sample measurements to demonstrate Zetasizer specifications (Zetasizer Nano, Zetasizer APS, Zetasizer μv)

Sample measurements to demonstrate Zetasizer specifications (Zetasizer Nano, Zetasizer APS, Zetasizer μv) Sample measurements to demonstrate Zetasizer specifications (Zetasizer Nano, Zetasizer APS, Zetasizer μv) Contents Size using Non-Invasive back-scatter (NIBS) optics Zetasizer Nano S/ZS...2 Minimum size

More information

Studying the Effect of Steric Layer Thickness on Emulsion Stability

Studying the Effect of Steric Layer Thickness on Emulsion Stability Studying the Effect of Steric Layer Thickness on Emulsion Stability Dr Tim J. Wooster, Professor Mary A. Augustin, Food Science Australia (CSIRO) of Chemistry, Monash University, Victoria 3800, Australia

More information

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES KINEXUS SERIES Redefining rheometer capabilities for characterizing dispersed systems At Malvern, we haven t just redesigned a rheometer we ve redefined

More information

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD Setting the Standard WHAT CAN ADVANCED GPC/SEC DETECTION OFFER YOU? A modern research environment

More information

Measuring the flow properties of powders. FT4 Powder Rheometer. freemantechnology

Measuring the flow properties of powders. FT4 Powder Rheometer. freemantechnology Measuring the flow properties of powders FT4 Powder Rheometer freemantechnology Efficiency, quality and productivity Successful powder processing requires the ability to reliably and repeatably predict

More information

Use of DLS/Raman to study the thermal unfolding process of lysozyme

Use of DLS/Raman to study the thermal unfolding process of lysozyme Use of DLS/Raman to study the thermal unfolding process of lysozyme A Malvern Instruments' Bioscience Development Initiative Executive summary The combination of dynamic light scattering (DLS) and Raman

More information

DRY METHOD DEVELOPMENT FOR LASER DIFFRACTION PARTICLE SIZE MEASUREMENTS

DRY METHOD DEVELOPMENT FOR LASER DIFFRACTION PARTICLE SIZE MEASUREMENTS DRY METHOD DEVELOPMENT FOR LASER DIFFRACTION PARTICLE SIZE MEASUREMENTS Developing an appropriate method for measuring particle size distribution of powders dispersed in air using laser diffraction requires

More information

GPC/SEC Analysis of Polymer Solutions Used in Inkjet Printing

GPC/SEC Analysis of Polymer Solutions Used in Inkjet Printing GPC/SEC Analysis of Polymer Solutions Used in Inkjet Printing Introduction Inkjet printing of polymer solutions is an area of interest for depositing precise, high-throughput patterns of functional polymer.

More information

Understanding the colloidal stability of protein therapeutics using dynamic light scattering

Understanding the colloidal stability of protein therapeutics using dynamic light scattering Understanding the colloidal stability of protein therapeutics using dynamic light scattering A Malvern Instruments' Bioscience Development Initiative Executive summary The combination of dynamic light

More information

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES KINEXUS SERIES Redefining rheometer capabilities for characterizing dispersed systems At Malvern, we haven t just redesigned a rheometer we ve redefined

More information

The Diffusion Barrier Technique, Practical Aspects and Data interpretation

The Diffusion Barrier Technique, Practical Aspects and Data interpretation The Diffusion Barrier Technique, Practical Aspects and Data interpretation Introduction The diffusion barrier technique is a method for reliably measuring the electrophoretic mobility of proteins by minimising

More information

Method Development. Creating the Perfect Standard Operating Procedure (SOP) 2007 HORIBA, Ltd. All rights reserved.

Method Development. Creating the Perfect Standard Operating Procedure (SOP) 2007 HORIBA, Ltd. All rights reserved. Method Development Creating the Perfect Standard Operating Procedure (SOP) Method Development Goal: Reproducible method that tracks product performance Choose measurement approach (dry vs. suspension)

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy Morphologi G3-ID CHEMICAL IDENTIFICATION PARTICLE SHAPE PARTICLE SIZE PROTEIN

More information

The power of multi-detector SEC in the analysis of antibodies

The power of multi-detector SEC in the analysis of antibodies The power of multi-detector SEC in the analysis of antibodies How OMNISEC can measure antibody absolute MW independent of size and structural changes MOLECULAR SIZE MOLECULAR STRUCTURE MOLECULAR WEIGHT

More information

How to use GPC/SEC for compositional analysis

How to use GPC/SEC for compositional analysis How to use GPC/SEC for compositional analysis Determining the relative concentration of two components in a polymer sample MOLECULAR SIZE MOLECULAR STRUCTURE MOLECULAR WEIGHT Introduction Over the last

More information

The Elzone II Particle Count and Size Analyzer

The Elzone II Particle Count and Size Analyzer The Elzone II 5390 Particle Count and Size Analyzer Elzone II Overview of Basic Theory Operates using the Electrical Sensing Zone (ESZ) Principle, also known as the Coulter Principle. First commercially

More information

Laser diffraction and automated imaging: complementary techniques for nasal spray development

Laser diffraction and automated imaging: complementary techniques for nasal spray development Laser diffraction and automated imaging: complementary techniques for nasal spray development PARTICLE SIZE PARTICLE SHAPE Together the techniques of laser diffraction and automated particle imaging support

More information

Morphologically directed chemical identification Coupling particle characterization by morphological imaging with Raman spectroscopy

Morphologically directed chemical identification Coupling particle characterization by morphological imaging with Raman spectroscopy Inform is a series of white papers designed to provide advice on material characterization issues Morphologically directed chemical identification Coupling particle characterization by morphological imaging

More information

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz LABOTRON EXTRACTION & SYNTHESIS 2450 MHz The LABOTRON TM series is the generic name for a ground breaking range of integrated reactor and microwave transmission systems especially designed to carry out

More information

Differentiation of polymer branching and composition using the Mark Houwink plot

Differentiation of polymer branching and composition using the Mark Houwink plot Differentiation of polymer branching and composition using the Mark Houwink plot MOLECULAR SIZE MOLECULAR STRUCTURE MOLECULAR WEIGHT Introduction The manipulation of polymer properties through changes

More information

Introduction to the calculators in the Zetasizer software

Introduction to the calculators in the Zetasizer software Introduction to the calculators in the Zetasizer software PARTICLE SIZE ZETA POTENTIAL MOLECULAR WEIGHT MOLECULAR SIZE Introduction The calculators are a series of tools in the Zetasizer software that

More information

Measurements of protein electrophoretic mobility using the Zetasizer Nano ZSP

Measurements of protein electrophoretic mobility using the Zetasizer Nano ZSP Measurements of protein electrophoretic mobility using the Zetasizer Nano ZSP Introduction Zetasizer Nano is the market leader in dynamic and electrophoretic light scattering technology for measurements

More information

Particle Analyzer CAMSIZER XT

Particle Analyzer CAMSIZER XT Particle Analyzer CAMSIZER XT Particle size and particle shape measurement with Dynamic Image Analysis Measurement of fine powders, granules and suspensions in a range from 1 µm to 3 mm Precise measurement

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion

More information

473 Dew Point Hygrometer

473 Dew Point Hygrometer High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct

More information

LABSONIC The convenient ultrasonic homogenizer for your laboratory

LABSONIC The convenient ultrasonic homogenizer for your laboratory LABSONIC The convenient ultrasonic homogenizer for your laboratory LABSONIC Ultrasonic homogenizers for every application The LABSONIC M and LABSONIC P homogenizers from Sartorius are compact laboratory

More information

The solution for all of your

The solution for all of your The solution for all of your nanoparticle sizing and zeta potential needs. DelsaNano Series Blood Banking Capillary Electrophoresis Cell Analysis Centrifugation Genomics Lab Automation Lab Tools Particle

More information

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

PTG-NIR Powder Characterisation System (not yet released for selling to end users) Powder Characterisation System - PTG-NIR PTG-NIR Powder Characterisation System (not yet released for selling to end users) The PTG-NIR automatic powder and granule inspection system with integrated NIR

More information

How switching mobile phases can improve your OMNISEC results

How switching mobile phases can improve your OMNISEC results How switching mobile phases can improve your OMNISEC results Analysis of ester- and acid-capped PLGA samples in mobile phases of DCM and THF MOLECULAR SIZE Introduction MOLECULAR Biodegradable, thermoplastic

More information

Using the Zetasizer Nano to optimize formulation stability

Using the Zetasizer Nano to optimize formulation stability Using the Zetasizer Nano to optimize formulation stability PARTICLE SIZE ZETA POTENTIAL The top five ways you can use the Zetasizer Nano to help improve the stability of your formulation. Formulation development

More information

Measuring the rheology of thermoplastic polymer melts

Measuring the rheology of thermoplastic polymer melts Measuring the rheology of thermoplastic polymer melts Using rotational and capillary rheometry to characterize polymer melts RHEOLOGY AND VISCOSITY Introduction Rheology is the science of studying the

More information

Particle Charge Titration Zeta Potential Size Distribution

Particle Charge Titration Zeta Potential Size Distribution Particle Charge Titration Zeta Potential Size Distribution Stabino NANO-flex ZETA-check (without Titration) Stabino ZETA-check Rapid Particle Charge Titrations and Size Distribution In many applications,

More information

Systems, services and solutions for material characterization

Systems, services and solutions for material characterization Particle size Zeta potential Particle shape Absolute molecular weight Rheological properties Systems, services and solutions for material characterization detailed specifications at www.malvern.co.uk Advanced

More information

ActiPix SDI300 Surface Dissolution Imaging System

ActiPix SDI300 Surface Dissolution Imaging System Product Note: PN002B Figure 1. SDI300 Surface Dissolution Imaging System Introduction The ActiPix SDI300 is a powerful UV area imaging system which enables quantitative imaging of surface phenomena for

More information

White Paper Optimization of Dry Powder Particle Size Analysis

White Paper Optimization of Dry Powder Particle Size Analysis -------------------------------------------------------------------White Paper Optimization of Dry Powder Particle Size Analysis Reprinted with permission from VertMarkets, Inc Optimization of Dry Powder

More information

PARTICLE SIZE CHARACTERISATION OF AGRICULTURAL SPRAYS USING LASER DIFFRACTION

PARTICLE SIZE CHARACTERISATION OF AGRICULTURAL SPRAYS USING LASER DIFFRACTION ILASS-Europe 2002 Zaragoza 9 11 September 2002 PARTICLE SIZE CHARACTERISATION OF AGRICULTURAL SPRAYS USING LASER DIFFRACTION Paul Kippax *, Steve Parkin ** and Clive Tuck ** Paul.Kippax@malvern.co.uk *

More information

Executive Summary. Introduction WHITEPAPER

Executive Summary. Introduction WHITEPAPER The Characterization of Single Wall Carbon Nanotubes Using The Malvern Instruments Helix System: Integrating Dynamic Light Scattering (DLS) and Raman Spectroscopy Executive Summary The combination of DLS

More information

QbD QUANTITATIVE MEASUREMENTS OF CQAS IN SOLID DOSAGE FORM UNIT OPERATIONS

QbD QUANTITATIVE MEASUREMENTS OF CQAS IN SOLID DOSAGE FORM UNIT OPERATIONS QbD QUANTITATIVE MEASUREMENTS OF CQAS IN SOLID DOSAGE FORM UNIT OPERATIONS Particle Size Material Segregation-Flow USP USP USP Ph. Eur. 2.9.31 Ph. Eur. 2.9.36 JP 1 JP 18 Light Diffraction

More information

LABORATORY LINE. REACTRON RT 1 and RT 2. Reaction and mixing processes at a laboratory level, modular design laboratory reactors

LABORATORY LINE. REACTRON RT 1 and RT 2. Reaction and mixing processes at a laboratory level, modular design laboratory reactors LABORATORY LINE REACTRON RT 1 and RT 2 Reaction and mixing processes at a laboratory level, modular design laboratory reactors Efficient and economic. RT 1 and RT 2 REACTRON laboratory systems consist

More information

Protocol Particle size distribution by centrifugal sedimentation (CPS)

Protocol Particle size distribution by centrifugal sedimentation (CPS) Protocol Particle size distribution by centrifugal sedimentation (CPS) 1. Method The CPS Disc Centrifuge separates particles by size using centrifugal sedimentation in a liquid medium. The sedimentation

More information

YOUR PARTNER IN PARTICLE CHARACTERIZATION

YOUR PARTNER IN PARTICLE CHARACTERIZATION YOUR PARTNER IN PARTICLE CHARACTERIZATION SERVICES escubed limited provides comprehensive analytical and research and development services in colloidal, particulate and powder technology to customers across

More information

Particle Size and Shape Analysis in PHARMACEUTICAL INDUSTRY.

Particle Size and Shape Analysis in PHARMACEUTICAL INDUSTRY. Particle Size and Shape Analysis in PHARMACEUTICAL INDUSTRY Generalities Many analytical methods exist for the characterization of products manufactured in the pharmaceutical industry. Measuring the size

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.

More information

Characterization of Single Wall Carbon Nanotubes (SWNTs) by combining Dynamic Light Scattering and Raman Spectroscopy

Characterization of Single Wall Carbon Nanotubes (SWNTs) by combining Dynamic Light Scattering and Raman Spectroscopy Characterization of Single Wall Carbon Nanotubes (SWNTs) by combining Dynamic Light Scattering and Raman Spectroscopy PARTICLE SIZE Executive Summary The combination of DLS and Raman spectroscopy offers

More information

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry RheolabQC Rotational Rheometer for Quality Control ::: Intelligence in Rheometry RheolabQC The Powerful QC Instrument Viscosity measurement and rheological checks for quality control are made routine and

More information

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis Application Note AN785 Extraction of Aflatoxins and chratoxin From Dried Chili Using ISLUTE Myco prior to LC-MS/MS Analysis Page Extraction of Aflatoxins and chratoxin from Dried Chili Using ISLUTE Myco

More information

Organic Polymer Feeding

Organic Polymer Feeding Organic Polymer A successful Nalco polymer program requires the appropriate equipment to efficiently make up and feed the polymer. The feed equipment selected for a certain application depends on the polymer

More information

The Fundamentals of Moisture Calibration

The Fundamentals of Moisture Calibration The Fundamentals of Moisture The following guide will provide you with a basic knowledge of humidity calibration, help you to understand your requirements and select an appropriate solution. 1 Why Humidity

More information

Surface Zeta Potential Cell (ZEN1020)

Surface Zeta Potential Cell (ZEN1020) Surface Zeta Potential Cell (ZEN1020) MAN0483 Issue 1.0 September 2011 English Copyright Malvern Instruments Ltd. 2011 Malvern Instruments makes every effort to ensure that this document is correct. However,

More information

MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20

MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20 MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20 Introduction Protein aggregation is recognised as a major issue in the biopharmaceutical industry. Proteins have a tendency to aggregate over

More information

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES APPLICATION NOTE 43145 Analysis of trace elements in polymer s to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES Authors Introduction Sanja Asendorf, Application

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

CILAS PARTICLE SIZE AND SHAPE ANALYSIS

CILAS PARTICLE SIZE AND SHAPE ANALYSIS DISPERSIONEN CILAS PARTICLE SIZE AND SHAPE ANALYSIS BUILDING MATERIALS SOILS AND SEDIMENTS PAINTS, INKS, LACQUERS GLASS AND CERAMICS HOME AND PERSONAL CARE PHARMACEUTICALS FOOD AND BEVERAGES GRAPHITE AND

More information

Compact ph Measuring Instruments With Pro Engineering

Compact ph Measuring Instruments With Pro Engineering testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode ph C The new ph instruments with innovative probe engineering Measurement of the ph

More information

Humidity Calibration Solutions

Humidity Calibration Solutions Humidity Calibration Solutions www.michell.com Humidity Calibration Solutions The Importance of Regular Calibration The reliable operation of a hygrometer and indeed any measuring instrument, can only

More information

LCTech GmbH Chromatographie

LCTech GmbH Chromatographie EVA III - an analytical preparation system for all kinds of applications a new system by LCTech that makes work so much easier Overview of Contents: y Broad Spectrum of Application y Automatisation of

More information

Litesizer Sheet 1. [Home]

Litesizer Sheet 1. [Home] Litesizer 500 15.01.15 Sheet 1 [Home] The Product: Litesizer 500 Measurement Modes Particle Size & Distribution Dynamic light scattering (DLS) Zeta Potential Electrophoretic light scattering (ELS) Molecular

More information

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) The Agilent

More information

X-CELL Analytical. Petroleum Fluids Analysis. St. Francis Xavier University Analytical Services Lab. Equipment Specification Brochure

X-CELL Analytical. Petroleum Fluids Analysis. St. Francis Xavier University Analytical Services Lab. Equipment Specification Brochure X-CELL Analytical Petroleum Fluids Analysis St. Francis Xavier University Analytical Services Lab Equipment Specification Brochure Physical Sciences Center PO Box 5000 Antigonish, NS, B2G 2W5 Canada Phone:

More information

A Basic Guide to INFORM WHITE PAPER. Abstract:

A Basic Guide to INFORM WHITE PAPER. Abstract: A Basic Guide to Abstract: The aim of this guide is to provide you with a basic grounding in the main particle characterization techniques currently in use within industry and academia. It assumes no prior

More information

FLASH CHROMATOGRAPHY

FLASH CHROMATOGRAPHY Turnkey Laboratories Solutions FLASH CHROMATOGRAPHY FC 3065 EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES Analytical Technologies Limited An ISO 9001 Certified Company

More information

Sympatec GmbH, System-Partikel-Technik, Burgstätterstraße 6, D Clausthal-Zellerfeld, Germany

Sympatec GmbH, System-Partikel-Technik, Burgstätterstraße 6, D Clausthal-Zellerfeld, Germany W. Witt and M. Heuer Sympatec GmbH, System-Partikel-Technik, Burgstätterstraße 6, D-38678 Clausthal-Zellerfeld, Germany Quick and Tubeless Suspension Analysis with Laser-diffraction 1 Introduction Laser

More information

DEVELOPING A BIOFORMULATION STABILITY PROFILE

DEVELOPING A BIOFORMULATION STABILITY PROFILE DEVELOPING A BIOFORMULATION STABILITY PROFILE Light Scattering and Micro-Capillary Viscometry A Malvern Instruments Bioscience Development Initiative Executive Summary: When used in combination, light

More information

Humidity Calibration Solutions

Humidity Calibration Solutions Instruments Humidity Solutions www.michell.com Instruments Humidity Solutions The Importance of Regular The reliable operation of a hygrometer and indeed any measuring instrument, can only be verified

More information

Malvern - Innovative Solutions in Material Characterization

Malvern - Innovative Solutions in Material Characterization Malvern - Innovative Solutions in Material Characterization Malvern solutions Advanced technology made simple Material Characterization for Industry Malvern recognizes and supports industry s continuing

More information

Determination of Solubility Parameters using Inverse Gas Chromatography

Determination of Solubility Parameters using Inverse Gas Chromatography Determination of Solubility Parameters using Inverse Gas Chromatography Anett Kondor PhD IGC-SEA Product Manager and igc Product Specialist 7 th April 017 Overview Introduction Inverse Gas Chromatography

More information

96 Well? Done! Eppendorf epmotion 96 semi-automated electronic pipette for fast and precise 96 channel microplate processing

96 Well? Done! Eppendorf epmotion 96 semi-automated electronic pipette for fast and precise 96 channel microplate processing 96 Well? Done! Eppendorf epmotion 96 semi-automated electronic pipette for fast and precise 96 channel microplate processing Try it and you will see how easy and fast your 96-well and 384-well plates get

More information

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination Measurement & Analytics Measurement made easy MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination Adapted for polyols and polyurethanes applications The MB3600-CH70 Polyol Analyzer

More information

ICP-MS. High Resolution ICP-MS.

ICP-MS. High Resolution ICP-MS. ICP-MS attom ES High Resolution ICP-MS www.nu-ins.com Attom ES Enhanced Sensitivity Enhanced Speed Enhanced Selectivity Enhanced Software The Attom ES from Nu Instruments is a double focussing inductively

More information

High Pressure Chemistry. Hydrogenation & Catalysis Tools.

High Pressure Chemistry. Hydrogenation & Catalysis Tools. High Pressure Chemistry Hydrogenation & Catalysis Tools www.helgroup.com HYDROGENATION AND CATALYSIS Product Selection Guide HEL Group s top quality high pressure reactors and systems offer innovative,

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Electrophoretic Light Scattering Overview

Electrophoretic Light Scattering Overview Electrophoretic Light Scattering Overview When an electric field is applied across an electrolytic solution, charged particles suspended in the electrolyte are attracted towards the electrode of opposite

More information

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple Reliable TOC measurements Stop throwing away your first rep. QbD1200 has virtually eliminated sample-to-sample carryover

More information

MORPHOLOGI 4 RANGE. Automated imaging for advanced particle characterization

MORPHOLOGI 4 RANGE. Automated imaging for advanced particle characterization MORPHOLOGI 4 RANGE Automated imaging for advanced particle characterization 2 MORPHOLOGICAL IMAGING FOR YOU Morphological imaging is fast becoming an essential technology in the laboratory toolkit for

More information

CRYSTA-APEX C. The modular system for 3D CNC coordinate measurement in the production environment. Quick, versatile and high performing.

CRYSTA-APEX C. The modular system for 3D CNC coordinate measurement in the production environment. Quick, versatile and high performing. Coordinate Measuring Machines CRYSTA-APEX C The modular system for 3D CNC coordinate measurement in the production environment. Quick, versatile and high performing. Future-proofed high performance. CRYSTA-APEX

More information

DI 3500 Discrete Aoalvzer

DI 3500 Discrete Aoalvzer DI 3500 Discrete Aoalvzer Automated Chemistry and Ion Analysis ':t O+Analytical:!, A World ofsolutions. - Discrete Analysis Efficient Microscale Chemistry Increasingly laboratories are being challenged

More information