Ion-selective Measurement (ISE)

Size: px
Start display at page:

Download "Ion-selective Measurement (ISE)"

Transcription

1 Ion-selective Measurement (ISE) Page 1 of 39

2 Table of contents 1 Basic information 1.1 Introduction to ion-selective measurement 1.2 Reference electrode design and principle of operation 1.3 Concentration and activity 1.4 Diffusion voltage, diffusion potential 1.5 Stirrer 1.6 Selectivity 2 Description of ion-selective electrodes 2.1 Solid-state electrodes 2.2 PVC membrane electrodes 2.3 Gas-sensitive electrodes 3 Calibration 3.1 One-point calibration 3.2 Two-point calibration 3.3 Multi-point calibration 4 Sample preparation 4.1 ph value 4.2 Interfering ions Precipitation Complexing Cooking 4.3 Trace analysis Shifting the nonlinear region of the characteristic curve Extraction Ion exchangers 5 Measurement methods 5.1 Direct potentiometry 5.2 Incremental methods Standard addition Double standard addition Standard subtraction Sample addition Sample subtraction Standard addition with blank value correction 5.3 Titration methods Direct titration Indirect titration Back titration End point indicator Page 2 of 39

3 6 Maintenance and special information 6.1 Electrode contamination 6.2 Cleaning the electrodes 6.3 Storing the electrodes 6.4 Faults during measurement and calibration 6.5 Measuring ranges 7 Bibliography 8 Appendix: Interfering Ions Page 3 of 39

4 1 Basic information 1.1 Introduction to ion-selective measurement Ion-selective measurement is an analytical method that frequently offers advantages over other methods. The most important advantages are: 1. Relatively low purchase costs 2. Rapid arrival at measuring results 3. Use in turbid and coloured solutions in which other methods such as photometry cannot be applied. This list of advantages could easily be extended. Of course, this method also has some disadvantages over other methods. At an error rate of 2-5%, the measuring accuracy is not particularly high. Nevertheless, it is perfectly adequate for many applications. Moreover, the method unfortunately cannot be used for every substance. It generally does not work for organic substances. However, it is particularly well suited for measuring ions, i.e. for the measurement of salts. Ions, the components of salts, are electrically charged particles. When an electrode is introduced into an ion solution, the ions interact with the electrode surface. Interaction means that ions accumulate on the electrode surface. This can be a two-part adsorption of the ions. Alternatively, ions may penetrate the electrode material. Finally, ions may become detached from the electrode and enter into the solution. An electrode is an electrical conductor that is immersed in the solution at one end and connected to a millivoltmeter at the other. In its simplest form, it is nothing more than a simple metal wire. Incidentally, substances that form free mobile ions in aqueous solutions are called electrolytes. Often this term is also used to refer to the ion solution itself. What is the significance of the interaction of the ions with the electrode? Ions are electrically charged particles. They carry an electrical charge onto the electrode, thereby generating a voltage between the electrode and the solution. In the ion-selective measuring technique, as shown below, the magnitude of this voltage is a function of the concentration of the ion to be measured. However, our measuring device in its present form is not yet capable of measuring a voltage at all since the second input of the device has not yet been defined. It would be ideal if we could simply connect the second input directly to the solution. However, this cannot be accomplished without the use of an electrical conductor. If we were to use such a conductor and immerse it in the solution, the same processes that take place at the surface of the first electrode would also occur at this conductor. Experience in the field has provided us with a similar solution. The second input is connected to a reference electrode. Essentially, this reference electrode operates in a manner similar to that already described above. However, it exhibits a constant voltage difference between the electrolyte output, with which the reference electrode is immersed in the solution, and the connection to the device. Thus, we have a fixed reference point with respect to which we can measure the voltage at the first electrode. If the surface of the first electrode is now coated with an ion-selective substance, i.e. with a substance that only interacts with a specific ion species, we then have the basic component needed for working with the ion-selective measuring technique. The ion-selective electrode and the reference electrode are collectively known as an electrode. If they are physically separated, they are referred to as a two-probe electrode. If they are combined in a single probe, they are known as a combination electrode. Page 4 of 39

5 As already indicated above, ion-selective measurement is about measuring voltage changes in order to draw conclusions about ion concentrations. To do so, we need to establish a physicalmathematical relationship between these two parameters. This is provided by the Nernst equation as the expression: RT E = E0 + 2,303 log c nf E Measured voltage between the measuring and reference electrodes E 0 Measured voltage between the measuring and reference electrodes at a concentration of c = 1 R Universal gas constant (R = Joule mol -1 K -1 ) T Absolute temperature in Kelvin (the absolute temperature is defined as T = t. The units are Kelvin K. t is the numerical value of the measured temperature in C. F Faraday constant (F = C mol -1 ) n Electrical ionic charge c Ion concentration R and F are constants and therefore not of further concern. Since temperature appears in the Nernst equation, the measured voltage is a function of the temperature. The ionic charge n influences a parameter we call the electrode slope. The Nernst slope is given by the expression: RT 2,303 nf Depending on the ionic charge, the slope has the following values in millivolt at 20 C and 25 C: Ionic charge Slope 20 C Slope 25 C Examples Copper (Cu 2+ ), lead (Pb 2+ ) Sodium (Na + ), potassium (K + ) Fluoride (F - ), chloride (Cl - ) Sulphide (S 2- ) In practice, many electrode types actually achieve these slopes. Only a few do not. If the slope decreases over time, this generally indicates ageing of the electrode. Finally, we should discuss the expression log c. While it may be difficult for some readers to understand this expression, this should not be grounds for rejecting the ion-selective measuring technique. After all, log c is usually not needed when performing standard measurements. Also, any good calculator today is capable of calculating the value. Example: Using a calculator that features the log function, enter the numerical value for concentration c and press the log key. The number that appear on the display is the value of log c and can be substituted in for log c in the Nernst equation. (A brief remark is in order regarding concentration c: For small and very small concentrations, the Nernst equation applies without limitations. Deviations arise for larger concentrations. Later we shall see that this problem can be solved by introducing the activity parameter.) Page 5 of 39

6 We will now try to plot the characteristic curve of an ion-selective electrode. This will make it easier to perform analyses later on. Also, this task is a good example that will help you understand this measurement technique. The characteristic curve of an ion-selective electrode represents the relationship between voltage E and concentration c. In other words, it is a graphic representation of the Nernst equation. Because of the log c expression, it is not practical to plot the concentration c itself on an axis. It is much more convenient to use the value of log c. The plot then takes on the form of a straight line. This procedure is easy to master. Using semi-logarithmic paper, we plot log c on the logarithmic axis and voltage E on the other. An example illustrates how this is done. Now let us move on to the practical part. We will record the characteristic curve of a bromide electrode. To do so, we require the following equipment and chemicals: Instrumentation 1 millivoltmeter (resolution of 0.1 mv, input impedance ) 1 bromide electrode (BR 500, Br 501) 1 reference electrode (R 502) 1 stirrer with stirrer bar 1 electrode stand 6 plastic beakers (150 ml volume) 8 graduated flasks (100 ml volume) 1 pipette (1 ml volume) 1 pipette (10 ml volume) Bromide standard with mg/l bromide Conducting salt solution: solution of 5 mol/l or 425 g/l sodium nitrate (The reason for using conducting salt will be explained later on.) We dilute the bromide standard to prepare two additional standard solutions, one of 100 mg/l bromide and the other of 1 mg/l bromide. Preparation of the 100 mg/l bromide standard Add 1 ml of mg/l bromide standard to a 100 ml graduated flask. The flask is filled to the calibration mark with deionized water and mixed well. Preparation of the 1 mg/l bromide standard Add 1 ml of 100 mg/l bromide standard to a 100 ml graduated flask. The flask is filled to the calibration mark with deionized water and mixed well. Measuring solutions are prepared in a similar manner according to the following table: Concentration of measuring solution mg/l bromide Volume of standard solution ml Standard solution mg/l bromide Volume of conducting salt solution ml Measured values mv Page 6 of 39

7 To prevent mistakes, the preparation of the 1000 mg/l bromide measuring solution is described here in detail. Preparation of the 1000 mg/l bromide measuring solution Add to a 100 ml graduated flask: 10 ml mg/l bromide standard 2 ml conducting salt solution Fill the flask to the calibration mark with deionized water and mix. The other solutions are prepared in a similar manner according to the table. The measuring solutions are now poured into plastic beakers and placed on the stirrer one after the other to be measured. The electrodes connected to the millivoltmeter are dipped into the solution with the aid of the electrode stand. The solution is stirred while readings are taken. The reason for stirring is described later on. The measured value usually drifts at the beginning of a particular measurement. After some time, the readings stabilise and the final value can be read and recorded before the next solution is measured in a similar manner. To avoid transferring substances from one measurement solution to the other, the electrodes are rinsed with deionized water after each measurement and the residual water is blotted with a soft paper towel. Surely not every reader will be able to reproduce these steps immediately. Therefore, the table also contains the values we ourselves measured in millivolts. How can we graphically represent the characteristic curve of the bromide electrode? A look at the semi-logarithmic graph paper reveals that the lines have a 1-mm spacing in one direction only. The voltage values are plotted in this direction, i.e. values of approx. 80 to approx. 180 mv. We recommend that 1 mm be used to represent 1 mv. In the other direction the line spacing varies. This is the logarithmic scale. The lines are arranged in such a way that when the concentration is plotted, the log c logarithm automatically generates a linear plot. This is precisely what we require and why the line spacing varies and repeats periodically. The same applies to the plotted numbers 2 to 10. For each number 10, we draw a short line and write below it the concentration of our measuring solutions, beginning from the right and moving along in ascending order. We can now plot the measuring points as usual. Fig. 1 shows this graph. Figure 1: Characteristic curve of a bromide electrode as a function of the decadic logarithm of the concentration Characteristic curve of bromide electrode Voltage mv log c Page 7 of 39

8 The following information can be gathered from this plot: 1. The plotted points for concentrations 1, 10, 100 and 1000 mg/l bromide lie in what is almost a straight line. This is the strictly linear part of the characteristic curve. The voltage difference between neighbouring points and, in general, between the concentrations, which have a ratio of 1 to 10, is 58.4 mv. We already encountered a value of this magnitude for the Nernst slope. In this case, however, it is referred to as the electrode slope. Mathematically, the value of this slope is negative, i.e. S = mv. This is easy to remember. All negatively charged ions, also known as anions, have negative slopes. A positive slope can also occur. The characteristic curve is then rotated by approx. 90. This is the case for all positively charged ions, which are also called cations. 2. The measuring points for concentrations 0.1 and 0.01 mg/l bromide no longer lie on the straight line. Thus, the characteristic curve has a nonlinear part. All ion-selective electrodes exhibit this phenomenon. The reason for this behaviour is found in the electrode structure. The ionselective membrane usually already contains the ion that is to be measured. Unfortunately, there are no perfectly insoluble substances in this field. Thus, a small quantity dissolves out of the membrane and introduces into the solution precisely that ion which is to be measured. If the measured concentrations are low, the magnitude of the dissolved ion concentration is significant. There is also another bothersome phenomenon found within this measuring range. The stabilisation period of the voltage can become extremely long. Frequently, one cannot be sure at what point the final value has actually been reached. 3. The characteristic curve can be used to determine the concentration of an unknown sample. The sample is usually prepared in the same manner as the solution for recording the characteristic curve. In this particular case, 2 ml conducting salt solution are added to 100 ml sample. The voltage of the solution is determined during stirring. The voltage reading is compared to the values in the plot of the characteristic curve and the corresponding concentration is found. This is done by drawing a line parallel to the concentration axis from the voltage value to the characteristic curve. At the point of intersection, a perpendicular is dropped to the concentration axis. The point of intersection with the concentration axis represents the concentration value we are looking for. To be precise, this value is actually the concentration of the measuring solution rather than of the sample itself. The sample was diluted. By performing a simple calculation, we can arrive at the concentration of the sample. For example, let us assume we have a measured value of 25 mg/l bromide. Our measuring solution had 102 ml and the sample had 100 ml. Thus, the absolute bromide quantity in the plastic beaker is 25 mg/l * l = 2.55 mg bromide. A 100 ml sample therefore contains a concentration of 2.55 mg/0.1 l = 25.5 mg/l bromide. Even if we haven t yet done so practically, we have at least theoretically carried out the first analysis using the ion-selective measuring technique. Incidentally, when this measuring technique was first developed, it was used in just this way. Only later did some companies build the first ion meters, which eliminated the need for recording measuring points. Today, modern ion meters are highly advanced and simplify the task for the user by offering many additional functions. However, even these devices require that at least two points of the characteristic curve be recorded, i.e. two solutions of know concentrations are needed. The user must enter these concentrations into the device. The device can then measure the corresponding voltages and determine the slope. The slope is generally indicated on the display. This entire procedure is referred to as calibration. In this particular case, it is also known as a two-point calibration. Most users employ this method. You should proceed in such a way that the expected sample concentration lies between the two calibration concentrations. This ensures that measurement imprecisions will have the lowest impact on the results. Page 8 of 39

9 When using new ion-selective electrodes for the first time, voltage stabilisation may be very sluggish at first. This does not necessarily mean that the electrode is defective. Rather, the electrode first requires conditioning, meaning that it must be kept in a diluted standard solution for several hours. This builds a so-called solvent layer on the membrane surface that accelerates voltage stabilisation. Of course, there is a lot more to say on many of the topics discussed here. There is also much to add from the point of view of physics and chemistry. Up to now we have refrained from touching on these topics to give the reader a chance to understand the basics of ion-selective measurement without the distraction of extraneous information. On the following pages, we now make up for this lapse. 1.2 Reference electrode design and principle of operation The most important property of a reference electrode has already been mentioned. At a fixed temperature, it guarantees that the voltage between the measuring device connection and the electrolyte outlet remains constant. The electrolyte will be referred to as the diaphragm from here on in. A constant voltage is indispensable for being able to measure voltage changes at the ionselective electrode. The function of the diaphragm is to provide the necessary electrical contact with the measuring solution. This is established by an electrolyte passing through the diaphragm. There are several types of diaphragms, including the ground diaphragm, ceramic diaphragm, pinhole diaphragm and platinum wire diaphragm. Ion-selective measurement usually employs the ground diaphragm. It has a relatively high flow rate and is easy to clean. It is also the diaphragm type that most reliably provides the defined electrical conditions with respect to the measuring solution. This issue is further discussed under Diffusion Potential or Diffusion Voltage. Since electrolyte continuously flows out of the reference electrode, it must be ensured that there is always an adequate quantity of electrolyte inside the reference electrode. When performing measurements, the electrolyte level within the reference electrode should be about 1 cm higher than the level of the measuring solution. How does the reference electrode generate a constant voltage? In the silver-silver chloride reference electrode, a silver wire coated with silver chloride plays a very important role. It is usually immersed in a chloride solution. Depending on the chloride concentration, a constant silver ion concentration is generated in the chloride solution (in a chemistry book, you will find this concept under solubility product). In accordance with the Nernst equation, the silver concentration generates a constant voltage between the chloride solution and the silver wire. The processes that take place at the silver wire have already been described in the introduction. This is the design of a simple reference electrode. For many applications, it does a good job of accomplishing the required tasks. However, what happens if we would like to measure small chloride ion concentrations? Then the ions that flow through the diaphragm into the solution are precisely those that we want to measure. Obviously, this does not allow for accurate measurement. In practice, therefore, the reference electrode consists of two parts. The actual reference electrode is contained in an internal chamber. Beyond it there is an additional diaphragm that leads to the outer chamber, which in turn comes into contact with the measuring solution through the ground diaphragm. The internal chamber has a chloride as an electrolyte (internal electrolyte, usually coloured), while the outer chamber contains an electrolyte of your choice (outer electrolyte). In this way we can select the electrolyte that flows into the measuring solution to match the measuring task at hand. The outer chamber is also called the bridge or electrolyte bridge, and the electrolyte is also referred to as the bridge electrolyte. Page 9 of 39

10 As already indicated, the voltage between the device connection and the ground diaphragm is only constant at a fixed temperature. A change in temperature brings with it a change in the voltage. This change is described by the Nernst equation and by the fact that the solubility of the silver chloride on the silver wire is temperature-dependent. Discharge electrode Reference electrolyte solution Internal bridge Bridge electrolyte solution Outer bridge Figure 2: Reference electrode Unfortunately, all voltages that contribute to the electrode voltage are temperature dependent. We have already noted the temperature-dependence of the electrode slope of the measuring electrode. To keep measurement errors caused by temperature fluctuations to a minimum, there is a basic rule that says the calibration temperature and the measuring temperature may not differ by more than 2 C. In modern WTW ion meters, the display blinks if this limit is exceeded. In addition to the silver-silver chloride electrode described here, which is the electrode type most commonly used today, other types of reference electrodes are also available. They differ in the nature of the electrochemical reactions on which they are based. The most familiar types are the calomel electrode and the thalamide electrode. The normal hydrogen electrode occupies a special position among electrodes. It is primarily employed in scientific research. It consists of a platinum plate that is coated with platinum black and immersed in hydrochloric acid with a concentration of 1 mol/l. Pure hydrogen gas at a pressure of p = 1 bar is bubbled over the electrode. By definition, this type of reference electrode has a potential of 0 mv at all temperatures. Because it is difficult to handle, it is not used for standard field work. Instead, either of the following electrodes are used: the silver-silver chloride electrode, which at 3 mol/l potassium chloride and a temperature of 25 C has a voltage of 208 mv with respect to the normal hydrogen electrode; or the calomel electrode, which at a temperature of 25 and a saturated potassium chloride solution exhibits a voltage of 244 mv with respect to the normal hydrogen electrode. Page 10 of 39

11 If a voltage measured against a particular reference electrode is to be converted to the corresponding value for the normal hydrogen electrode, the following simple conversion equation is used: U = U + U H gem U H = Voltage that would be measured using the normal hydrogen electrode U Gem = Measured voltage with respect to the reference electrode actually in use U Ref = Voltage of the reference electrode actually in use with respect to the normal hydrogen electrode Re f It is of no relevance which type of reference electrode is actually used for the ion-selective measurement. It has no effect on the nature of the characteristic curve. The use of different reference electrode merely causes the characteristic curve to shift to larger or smaller voltage values. 1.3 Concentration and activity We have already established that for low ion concentrations, the Nernst equation yields the correct voltage values. (This of course does not apply to concentrations in the nonlinear region of the characteristic curve). The calculated values closely coincide with the measured values. When measuring higher concentrations, however, deviations begin to appear. The ion solutions then behave as though a part of the ions were no longer present. There is an apparent loss in ions. This is a common phenomenon in chemistry. It is related to the fact that ions in high concentrations impede each other. To eliminate this source of error, a new entity, namely the activity, was introduced. The activity represents that portion of ions that are free to act. Mathematically, the activity is defined by the following equation: a i = f c i i a i = Activity of ion i c i = Concentration of ion i f i = Activity coefficient of ion i The activity coefficient is a function of the concentration and approaches the value of f i = 1 as the solution becomes more and more dilute. The activity then becomes equal to the concentration. With an increase in the concentration, the activity coefficient falls to values < 1 and the activity becomes smaller than the concentration. It has been shown that the activity coefficient depends not only on the concentration, but also on the ionic charge. A parameter that takes this into account is the ionic strength J. It is defined by the following equation: c i = Concentration of ion i z i = Charge of ion i J = 0,5 c i z i 2 A continuation of this line of thought produced a relationship between the activity coefficient f i and the ionic strength J. log f i = A J A = Constant Page 11 of 39

12 This equation is a mathematical expression for what we already know, namely that the activity coefficient depends on the ionic strength, which is a function of the concentration and charge of all ions in a solution. The addition of a conducting salt to the calibration and measuring solutions generates the same activity coefficient for all solutions. Under these conditions, the activity, which correctly appears in the Nernst equation, is proportional to the concentration. Therefore, we can then work with this entity as well. The difference between the activity and the concentration is cancelled out during calibration. Voltage Concentration Voltage Concentration Figure 3: Relationship between the concentration and the measured signal without and with the addition of a conducting salt Page 12 of 39

13 1.4 Diffusion voltage, diffusion potential Two different electrolyte solutions come into contact at the ground diaphragm of the reference electrode. They are the bridge solution and the measuring solution. Generally, they will differ in their composition and concentration. A voltage will usually be generated at bridges of this type. The voltage is generated from the difference in the diffusion speeds of the different ion species. For example, if the cations of one solution diffuse more rapidly into the other solution than the anions, a positively charged liquid front will build up, which is followed by a negative front. Separated electrical charges always give rise to an electrical voltage. Unfortunately, this voltage lies within the measuring circuit and is included in the measurements. The diffusion voltage, or the diffusion potential as this voltage is also called, can rise to values of 30 mv under certain conditions. In particular, this may be assumed to be the case when solutions with very different diffusion properties, such as acids and neutral salt solutions, border on each other. Considering that a measurement error of 1 mv results in a 4% error in the measurement results for monovalent ions and in an 8% error for divalent ions, it is clear that the diffusion voltage is the weakest link in the measurement circuit. Luckily, errors such as these can be prevented. For example, the salt concentration of the measuring solution can be raised. This is accomplished by adding salt to the measuring solution as described in the previous section, which already counts as a sample preparation. However, still more can be done. The generation of a diffusion voltage can be limited by the selection of suitable salts. If the cations and anions wander at roughly the same speeds, the ensuing diffusion voltage will only be small. This is the case for potassium chloride, potassium nitrate, ammonium chloride and, to a limited degree, for sodium nitrate and sodium chloride. The maintenance of identical calibration and measurement conditions is extremely important under this aspect. In technical jargon, the solutions used to add salt to the calibration and measuring solutions are known as ISA solutions. The abbreviation ISA stands for Ionic Strength Adjustor. Reference electrode Measuring medium K + Cl - Cl - Cl - K + K + K + K + Cl- K + ClK - + Cl - K + Cl - + K Cl - Cl - Figure 4: Balanced diffusion at the reference electrode diaphragm Page 13 of 39

14 1.5 Stirrer When working with ion-selective electrodes, we generally use a magnetic stirrer that allows uniform and comparable stirring of all solutions. Stirring has a stabilising effect on the diffusion voltage, that is, it brings about the constant values we require. Since this also accelerates the transportation processes at the measuring electrode and at the diaphragm, the voltage stabilisation periods are shortened as well. A disadvantage is that the stirrer can warm up the solution. An insulated plate between the stirrer and the vessel can effectively suppress this effect. 1.6 Selectivity Up to now, we have assumed that every ion-selective electrode responds only to one type of ion and remains unaffected by all other species. Unfortunately, this is not the case. For almost all electrodes, there are ions that we do not wish to measure, but that still affect the electrode signal. These ions are often called interfering ions and one speaks of interference error. Building on the Nernst equation, Nikolsky developed an equation that carries his name and allows a mathematical treatment of the interference effect. n i n s a i a j K is RT U = U 2,303 nif a j ai Charge of ion to be measured Charge of interfering ion species Activity of the ion to be measured Activity of the interfering ion species Sum of all interfering ion species Selectivity constant (measured ion interfering ion) n /n j i s 0 + log (ai + Kis a ) Strictly speaking, the selectivity constant K is is not really a constant since its value is a function of the ionic strength. Moreover, K is is also dependent on the method of determination. This especially applies to PVC membrane electrodes. In contrast, the selectivity constant of pure solid-state membrane electrodes is clearly a function of the solubility products. The Nikolsky equation shows that the interference effect increases with a rise in the interfering ion concentration and the selectivity constant. Therefore, it is advantageous to have a small selectivity constant. A small selectivity constant of means that the interfering ion, if it has the same concentration as the measured ion, causes only 1/1000 of the resulting voltage. However, it should be mentioned that some manufacturers of ion-selective electrodes specify the selectivity constant as the reciprocal value. This is always the case when the formulation more sensitive than is used. In practice, selectivity constants > 1 may also be encountered. This means: The interfering ion plays a greater role in generating the voltage than the measured ion itself. This is often the case with calcium electrodes, which are three times as sensitive to zinc ions than to calcium ions. As long as the calcium ions are not measured in the presence of zinc ions, as is usually the case, this fact will be of no importance. Page 14 of 39

15 2 Description of ion-selective electrodes Ion-selective electrodes can be categorised into three groups according to their design: 1. Solid-state electrodes 2. PVC membrane electrodes (matrix electrodes) 3. Gas-sensing electrodes 2.1 Solid-state electrodes The ion-selective membrane in these electrodes is a solid substance that is in direct contact with the measuring solution. Substances suitable as membrane material possess a very small yet detectable electrical conductivity, have ion-selective properties and are sparingly soluble in water, i.e. the solubility product is extremely small. Lanthanum fluoride is used for fluoride measurement since it dissolves in water to only 19.5 g/l. This minute amount is dissociated, i.e. it is completely broken down into ions. LaF 3 La F The ions are in equilibrium with the solid membrane and generate a voltage at the membrane that is a function of the fluoride or lanthanum concentration. The membrane has a glassy appearance and is very hard. The silver electrode is of similar design. A membrane of silver sulphide, Ag 2 S, is used. The solubility of this compound is almost a factor smaller than the solubility of the lanthanum fluoride. The dissociation is described by the following reaction: Ag + 2 2S 2 Ag + S Just as the fluoride electrode responds to lanthanum and fluoride, the silver electrode responds to silver and sulphide. Silver sulphide is very suitable for creating electrodes of the third type. These are electrodes whose membrane consists of a combination of silver sulphide, Ag 2 S, and either a sulphide of a heavy metal, MeS, or a silver halide, AgX. Both types of compounds are sparingly soluble in water. Electrodes with this membrane design respond to either the heavy metal or the halite ion. The scope of identifiable ions is thus usefully extended. The method of operation of these electrodes can be explained by looking at the equilibrium equations. In the electrodes that respond to heavy metals, the components Ag 2 S and MeS are present in the membrane. Both exist in the solution in a dissociated state: Ag + 2 2S 2 Ag + S MeS Me S 2 The second equilibrium is shifted to the left by the addition of the heavy metal ion, Me 2+, i.e. insoluble heavy metal sulphide is formed and the concentration of the sulphide ions, S 2-, decreases. This process affects the first equilibrium shown here. As the sulphide concentration decreases, the equilibrium is shifted to the right. This means: Silver sulphide, Ag 2 S, dissolves and the concentration of the voltage-determining silver ions, Ag +, increases. The sensitivity of the Ag 2 S/AgX mixtures to the halites has a similar explanation. Examples of electrodes with a heavy metal sulphide are the electrodes for lead, cadmium and copper; examples of electrodes with a silver halite are the electrodes for chloride, bromide, iodide and rhodanide. Page 15 of 39

16 With regard to the copper electrode, it should be added that its ion-selective membrane is photosensitive. The electrode voltage varies depending on the intensity of illumination in the laboratory. This may no longer be tolerated by the acceptance criterion of modern ion meters. Also, the use of a copper chloride standard for the calibration should be avoided because it gives rise to the following equilibrium: 2+ Ag2 S + Cu + 2 Cl 2 AgCl + CuS The silver chloride on the membrane of the electrode is sparingly soluble and slowly converts the copper electrode into a chloride electrode. It delivers an interference voltage that is a function of the chloride concentration. When measuring the sample, small chloride concentrations can be tolerated to a certain degree. This depends on the concentration conditions. More information is provided in the operating manuals of the copper electrode. The cyanide electrode represents a special case. It is actually a standard iodide electrode whose membrane consists of silver sulphide, Ag 2 S, and silver iodide, AgJ. The cyanide ion is a good complex builder for heavy metals and slowly dissolves the silver iodide of the electrode: AgJ + CN AgCN + J or AgJ + 2 CN Ag(CN) 2 + J The iodide electrode responds to the liberated iodide. Electrodes that slowly dissolve in the measured medium are also called corrosion electrodes. Care should be taken not to leave them in the measuring solution for longer than necessary. The iodide electrode, however, can do still more. The thiosulphate ion, like the cyanide ion, is capable of forming stable complexes with silver ions, which makes it possible to measure the thiosulphate. The iodide electrode can even be used to measure mercury silver ions within the concentration range of 10-4 to 10-8 mol/l. Mercury-II salts also dissolve the silver iodide. However, in this reaction it is the silver ion rather than the iodide ion that is liberated. This is of secondary importance for the measurement. 2+ AgJ + Hg HgJ + Ag + + The last solid-state electrode to be discussed here is the sodium electrode. On the surface, it has a different design than the electrodes discussed up to now and is very similar to the ph electrodes. This is not a coincidence. After all, it was developed on the basis of the ph electrode. The electrode voltage of ph electrodes exhibits deviations from the linear characteristic that are called alkaline error and acid error. The alkaline error can be increased by selecting a suitable glass type. If an electrode of this type is placed in a solution with a high constant ph value, it develops a sensitivity for sodium ions. To establish and maintain the ph value, buffer solutions based on organic amines are required. A sodium electrode can determine sodium concentrations as low as 0.02 to mg/l. However, preparation of the buffer requires very good water, i.e. water that is low in sodium, and very clean laboratory procedures since traces of sodium are widespread. Page 16 of 39

17 2.2 PVC membrane electrodes (matrix electrodes) There are many ions for which there are no known membrane substances that are sufficiently sparingly soluble to be able to use them in solid-state electrodes. However, there are substances that are in part organic which are able to form complexes with the ions to be measured or that have ion exchange properties. Substances such as these are dissolved in organic solvents. The substance and solvent should be sparingly soluble in water. The ion to be measured is capable of migrating in both directions across the border area between the organic solvent and the water. This builds up a voltage jump. To create electrodes that are practical to use, the organic solvent is polymerised into a PVC membrane together with the ion-selective organic substance. Many manufacturers build PVC membrane electrodes that are similar in design to the solid-state electrodes, the only difference being that the PVC membrane is found at the end of the head which is screwed onto the other part of the electrode. Because the PVC membrane is exhausted after ¼ to 1 year at the latest, the availability of a separate, exchangeable measuring head lowers the costs of measuring with these electrodes. The lifetime of the membrane largely depends on the frequency of use. 2.3 Gas-sensing electrodes These sensors are actually not counted among the ion-selective electrodes, since they are designed to respond to gasses. However, they can be used to determine ion concentrations as well, and we will discuss them here briefly in this capacity. As an example, we will single out the ammonia electrode, which is used to determine ammonium concentrations. From a chemical point of view, the following equilibrium exists between the ammonium ion, NH 4 +, and ammonia, NH 3 : + + NH3 + H2O NH4 OH This equilibrium indicates that the ammonium ion dominates in a strongly acidic solution, while ammonia gas dominates in a strongly alkaline solution. Each form can be converted to the other by shifting the ph. There is an intermediate range in which the ammonium ion exists alongside the ammonia in a particular ratio. At a ph of 9.25, the ratio is 1:1. At a ph of 12.25, only 1/1000 exists in the form of the ammonium ion, i.e. practically all ammonium ions will have been converted into ammonia. How can the ammonia be measured in order to determine the concentration of ammonium ions? In principle, the ammonia, which is dissolved in the alkaline solution, is allowed to diffuse through a Teflon membrane into a chamber that contains an ammonium chloride solution with a relatively high concentration. The equilibrium shown above now takes effect, i.e. the ammonia reacts with water and produces ammonium ions and OH - ions. The formulation of the equilibrium using the mass action law yields the following expression: a OH a = K a NH3 + NH4 a OH - K a NH3 + a NH4 Activity of the OH - ions Equilibrium constant Activity of the ammonia Activity of the ammonium ion Page 17 of 39

18 If we assume that the activity of the ammonium ion is constant, we have the following relationship: a OH = K a NH 3 This equation shows: When in equilibrium, the activity of the OH - ions is proportional to the activity of the ammonia. Due to the diffusion equilibrium, this also applies to the activity of the ammonium ions in the original sample. Thus, by measuring the voltage at a ph electrode, we can determine the ammonium concentration. The electrode design differs only marginally from the ion-selective measuring apparatus. We connect the ammonia electrode to our ion meter, calibrate the device with two ammonium standards that have been made alkaline and directly measure the ammonium concentration in the sample that has been made alkaline. To prevent ammonia from escaping from the solution, which would lead to a result that lies below the actual value, it is advisable to calibrate and measure in a closed vessel. If a closed vessel is used, the ammonia electrode does not even have to be dipped into the alkaline solution. Measurements can be made in the gaseous phase because it, too, builds up an equilibrium. Electrodes that work on the same principle as the ammonia electrode described above have been built for other systems as well. The most important ones are: Carbon dioxide/hydrogen carbonate Sulphur dioxide/hydrogen sulphite Hydrocyanic acid/cyanide Hydrofluoric acid /fluoride Hydrogen sulphide/hydrogen sulphide Naturally, the sample preparation differs for each system and the solutions for establishing a defined ph value have different compositions. 3 Calibration The user can select from three different calibration procedures depending on the design and features of the ion meter. 1. One-point calibration 2. Two-point calibration 3. Multi-point calibration 3.1 One-point calibration A prerequisite to using this procedure is that you must have available to you an ion meter on which the slope of the characteristic curve can be adjusted and the characteristic curve itself can be shifted horizontally. The theoretical slope is usually used. The equipment is calibrated using a single calibration standard. The electrode is dipped into the standard. The characteristic curve on the ion meter is now shifted until the reference value of the calibration standard is reached. This procedure is often the method of choice for production control purposes. The concentration of the calibration standard should be very close to that of the product. Under these conditions, a slope that has not been precisely set to the actual value has little bearing on the results. The advantage of this method is the speed with which both the procedure and a calibration check can be performed. Also, it avoids the expense of having to have a second calibration solution. Page 18 of 39

19 3.2 Two-point calibration The two-point calibration precisely defines the characteristic curve of the electrode by recording two measuring points. At the same time it calculates the slope. Two calibration standards are needed to record the two measuring points. Their concentration must be entered into the device. The standards are generally prepared by the user since solutions with a low concentration have a limited shelf life and also because the sample preparation must be taken into account when calibrating. The concentrations of the calibration standard should differ by a factor of 10. A smaller difference will have a negative effect the accuracy of the calibration. With a larger difference you run the risk of going well into the nonlinear range of the characteristic curve. It is advisable to define the calibration standards in such a way that the expected measured value lies between the two calibration points. Since the characteristic curve is a function of the temperature, the two calibration standards must be at the same temperature. The temperature during measurement should deviate as little as possible from this temperature. A deviation of 2 C is considered to be the absolute limit. E 2 E 1 Figure 5: Example of a two-point calibration c 1 c Multi-point calibration The purpose of the multi-point calibration is to determine where the characteristic curve deviates from a straight line during calibration in order to achieve a higher accuracy during measurement. This may not be of very great significance for a three-point calibration, since the user can select the required calibration points for the two-point calibration. However, if 5 or 6 calibration points are available, the nonlinear part of the characteristic curve can be reproduced, making this range available for measurement as well. The two-point calibration would fail in this region of the curve. In practice, the multi-point calibration reproduces the entire characteristic curve between the calibration points. One method is to use the polygon procedure where the ion meter uses straight lines to connect the calibration points. However, a more accurate method is the polynomial procedure. Here the device calculates the characteristic curve with a high degree of accuracy using polynomials of the fourth order. Be aware that the polynomial is only defined between the first and last standard. Measuring samples outside of this range can lead to errors. This situation can be avoided by selecting a more suitable calibration standard. Many ion meters output a warning when the measurement range limit is exceeded. When taking measurements, you should also know that the electrode voltages adjust very slowly in the nonlinear range of the characteristic curve. Page 19 of 39

20 6-point calibration with a nonlinear region Voltage Concentration c Figure 6: Example of a 6-point calibration with a nonlinear region 4 Sample preparation Samples are prepared with the aim of ensuring that the conditions for measurement are optimal. After preparation, the sample to be measured should be in a condition where the ions are in a free state. Any factors that arise from the measuring solution and can affect the electrode must be constant at all times. This applies to both the calibration and the measuring solutions. Any interfering ions should be removed. The most important method of sample preparation has already been presented. It is the use of ISA solutions. In the calibration and measuring solutions, the concentration of ISA solutions with a value of 1.1 should be 0.1 mol/l. The ISA solutions ensure that the electrical conductivity of the solutions is adequate, the diffusion voltage remains constant and the activity coefficient of the measured ion also remains constant. If the sample already has this concentration of salts, then adding ISA solution would be superfluous. Solutions with a salt content greater than 1 mol/l are diluted as required. Other methods of sample preparation are available and are described here in detail: 4.1 ph value It is necessary to establish specific ph ranges if the ion to be measured reacts with the H + or OH - ions at lower or higher ph values. The reaction products cannot be detected by the ion-selective electrode. For example, if ph values are too high, the ions of the heavy metals silver, copper, lead and cadmium are precipitated as hydroxides. Likewise, the measurement of fluoride is disturbed because the OH - ions cause the lanthanum fluoride in the membrane to be converted into lanthanum hydroxide. Especially at low concentrations, the liberated fluoride ions simulate a higher fluoride concentration. On the other hand, incorrect measured values can also result from solutions that are too acidic. For example, this is the case for the fluoride, cyanide, sulphide and thiocyanate anions. From these anions, H + is taken up to form undissociated acids that cannot no longer be detected. As a corrective measure, it is advisable to substitute the ISA solution with a suitable buffer. The specifications in the application reports provided by the companies should be observed. Page 20 of 39

21 4.2 Interfering ions As mentioned above, there is a very large number of different interfering ions, which is why only the most important examples will be discussed here. The procedures available for eliminating these interfering ions are precipitation, complexing and cooking Precipitation High concentrations of lead interfere with cadmium measurement. Since lead sulphate is sparingly soluble, an ISA solution of 5 mol/l sodium sulphate is used here. Iron-II ions interfere with the measurement of lead, cadmium and copper. Several milliliters of hydrogen peroxide are added to raise the ph value to 5-6. By adding ammonia solution drop by drop, iron-iii hydroxide precipitates and can be filtered out. Calcium measurement is disturbed by the divalent ions of iron, copper, magnesium, nickel and zinc. These ions can be precipitated at a ph value of 8. The calcium can then be directly measured at this ph value. Carbonates are destroyed prior to measurement (see below). Nitrate measurement is disturbed by iodide, cyanide, bromide, chloride, hydrogen sulphide and phosphate ions. Here, an ISA solution containing silver sulphate is used. The interfering ions are precipitated. Specifically for nitrate measurement in the presence of chloride, WTW sells a nitrate TISAB solution that contains silver ions (TISAB: total ionic strength adjustment buffer). If carbon acids are also interfering with the nitrate electrode, they can be precipitated by the addition of an ISA solution with 0.1 mol/l aluminium sulphate Complexing Often the ions to be determined are bound in complexes or are themselves complexing agents. Fluoride is an example for the latter case. Many metal ion species can form complexes with fluoride, which then can no longer be identified by an ion-selective electrode. Therefore, a TISAB solution is added to the sample solutions. The CDTA (Titriplex IV) contained in the TISAB solutions enters into a more stable complex with the metal ion than with the fluoride. The fluoride is displaced from the original complex and can then be measured. A ph value of 5-6 is used. This procedure has proved effective in most cases. However, for aluminium and iron fluoride complexes, it is often more advantageous to use TIRON (disodium catechol disulphonate) at a ph value of 6-7. The other case also occurs, namely that the ion to be determined is made unavailable for measurement by a complexing agent. To bring the ion into a form that is measurable, the complexing agent must be destroyed. For example, for the many different cyanide complexes, the metal ion can generally be liberated by treatment with acid. Dilute sulphuric acid will be sufficient for complexes that are easily dissociated. Those that are more difficult to dissociate must be treated with concentrated sulphuric acid. Caution: extremely toxic hydrocyanic acid is produced when cyanide complexes are dissociated. The dissociation reaction must therefore be performed under a good fume hood Cooking Certain interfering ions can be removed by cooking. These include the cyanide ion. The sample is made acidic and heated. Caution: In an acidic environment, the cyanide ions can form extremely toxic hydrocyanic acid. Therefore, removal of the cyanide must take place under a fume hood. Carbonates can also be removed by this method. A different procedure is used if large quantities of ammonium ion are an interference factor. Here, the ph value is raised to approximately 13. The heat causes the gaseous ammonia generated from the ammonium ion to escape. It has a biting odour (fume hood). Page 21 of 39

F- Cl- Br- I- CN- S2- NO3-

F- Cl- Br- I- CN- S2- NO3- Middle of the 60 s First ISE for fluoride Na+ K+ Ag+ Ca2+ NH + 4 Cu2+ Pb2+ F- Cl- Br- I- CN- S2- NO3- Environment Food industry and agriculture Medecine, pharmaceutical, cosmetics Power plants Fluoride

More information

GENERAL INSTRUCTIONS GENERAL PREPARATION

GENERAL INSTRUCTIONS GENERAL PREPARATION GENERAL INSTRUCTIONS Introduction The Van London-pHoenix Company Fluoroborate Ion Selective Electrode is used to quickly, simply, accurately, and economically measure Fluoroborate in aqueous solutions.

More information

GENERAL INSTRUCTIONS GENERAL PREPARATION

GENERAL INSTRUCTIONS GENERAL PREPARATION GENERAL INSTRUCTIONS Introduction The Van London-pHoenix Company Ammonium Ion Selective Electrode is used to quickly, simply, accurately, and economically measure potassium in aqueous solutions. Required

More information

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015 Ion Selective Electrodes for the Laboratory Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015 Outline Review ISE measurement technology How to properly calibrate

More information

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste Experiment ISE: Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste 67 You have been hired by the government to check the fluoride concentration labelling on some major

More information

Na+ K+ Ag+ Ca2+ NH + 4. F- Cl- Br- I- CN- S2- NO3-

Na+ K+ Ag+ Ca2+ NH + 4. F- Cl- Br- I- CN- S2- NO3- 1 1 HISTORY 2 Middle of the 60 s First ISE for fluoride Na+ K+ Ag+ Ca2+ NH + 4 Cu2+ Pb2+ F- Cl- Br- I- CN- S2- NO3- Until the 60 s the only ISE is in fact the ph electrode with a glass sensitive to protons.

More information

Experiment 8 - Double Displacement Reactions

Experiment 8 - Double Displacement Reactions Experiment 8 - Double Displacement Reactions A double displacement reaction involves two ionic compounds that are dissolved in water. In a double displacement reaction, it appears as though the ions are

More information

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE 1.0 SCOPE AND APPLICATION 1.1 This method can be used for measuring total solubilized nitrate in drinking

More information

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0) 150mV 300mV Mono/Reference Combination S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) 1376 340 456 Fax: +44 (0) 1376 340 453 Email:

More information

PRACTICAL 3 ph AND BUFFERS

PRACTICAL 3 ph AND BUFFERS PRACTICAL 3 ph AND BUFFERS ph and Buffers Structure 3.1 Introduction 3.2 ph and Buffers: Basic Concept 3.2.1 ph 3.2.2 Buffers and Buffer Solutions 3.3 Methods for Determining ph Experiment 1: Measurement

More information

The Cole-Parmer Nitrate Ion Electrodes are used to quickly, simply, accurately, and economically measure nitrate in aqueous solutions.

The Cole-Parmer Nitrate Ion Electrodes are used to quickly, simply, accurately, and economically measure nitrate in aqueous solutions. COLE-PARMER NITRATE ION ELECTRODES INSTRUCTION MANUAL GENERAL INSTRUCTIONS Introduction The Cole-Parmer Nitrate Ion Electrodes are used to quickly, simply, accurately, and economically measure nitrate

More information

Chapter 3 Electrochemical methods of Analysis-Potentiometry

Chapter 3 Electrochemical methods of Analysis-Potentiometry Chapter 3 Electrochemical methods of Analysis-Potentiometry Electroanalytical chemistry Contents Introduction Galvanic and electrolytic cells Salt bridge Electrode potential and cell potential Indicator

More information

COLE-PARMER LABORATORY NITRATE ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER LABORATORY NITRATE ION ELECTRODE INSTRUCTION MANUAL COLE-PARMER LABORATORY NITRATE ION ELECTRODE INSTRUCTION MANUAL Cole-Parmer Instrument Company (800)323-4340 Fax:(847)247-2929 625 East Bunker Court, Vernon Hills, Illinois 60061 http://www.coleparmer.com

More information

Use a pipet bulb when pipeting cyanide solutions, as these solutions are highly toxic.

Use a pipet bulb when pipeting cyanide solutions, as these solutions are highly toxic. GENERAL INSTRUCTIONS Introduction The Van London Co. Cyanide Ion Selective Electrode is used to measure dissolved cyanide ion in aqueous solutions. *IMPORTANT NOTICE* Acidic cyanide solutions produce hydrogen

More information

Operating Instructions for Ammonium ISE Specifications

Operating Instructions for Ammonium ISE Specifications Operating Instructions for Ammonium ISE Specifications Range: The Ammonium Electrode responds to uncomplexed ion activity over the range 1 x 10-1M to 1 x 10-6M. Linear detection limit is about 10-5M Interference's:

More information

Instrumental Chemical Analysis. Dr. Abdul Muttaleb Jaber Professor Faculty of Pharmacy Philadelphia University Fall 2012/2013

Instrumental Chemical Analysis. Dr. Abdul Muttaleb Jaber Professor Faculty of Pharmacy Philadelphia University Fall 2012/2013 0510212 Instrumental Chemical Analysis Dr. Abdul Muttaleb Jaber Professor Faculty of Pharmacy Philadelphia University Fall 2012/2013 Chapter 1 Electroanalytical Methods Electroanalytical Chemistry Electroanalytical

More information

CHAPTER 14: ELECTRODES AND POTENTIOMETRY

CHAPTER 14: ELECTRODES AND POTENTIOMETRY CHAPTER 14: ELECTRODES AND POTENTIOMETRY Chapter 14 Electrodes and Potentiometry Potentiometry : The use of electrodes to measure voltages that provide chemical information. (The cell voltage tells us

More information

For the element X in the ionic compound MX, explain the meaning of the term oxidation state.

For the element X in the ionic compound MX, explain the meaning of the term oxidation state. 1. (a) By referring to electrons, explain the meaning of the term oxidising agent.... For the element X in the ionic compound MX, explain the meaning of the term oxidation state.... (c) Complete the table

More information

Titration of a strong acid with a strong base with Cobra4

Titration of a strong acid with a strong base with Cobra4 Titration of a strong acid with a strong base with Cobra4 TEC Related topics Strong and weak acids and bases, ph value, titration curves, equivalence point, potentiometry. Principle Hydrochloric acid is

More information

Try this one Calculate the ph of a solution containing M nitrous acid (Ka = 4.5 E -4) and 0.10 M potassium nitrite.

Try this one Calculate the ph of a solution containing M nitrous acid (Ka = 4.5 E -4) and 0.10 M potassium nitrite. Chapter 17 Applying equilibrium 17.1 The Common Ion Effect When the salt with the anion of a is added to that acid, it reverses the dissociation of the acid. Lowers the of the acid. The same principle

More information

Fig. Electrochemical Cell/ Potentiometric Titration

Fig. Electrochemical Cell/ Potentiometric Titration Fig. Electrochemical Cell/ Potentiometric Titration The accurate, precise and effective potentiometric measurements can be made with the help of the following two types of electrodes namely : REFERENCE

More information

CHM-201 General Chemistry and Laboratory I Laboratory 4. Introduction to Chemical Reactions (based in part on Small Scale Chemistry methodology as

CHM-201 General Chemistry and Laboratory I Laboratory 4. Introduction to Chemical Reactions (based in part on Small Scale Chemistry methodology as CHM-201 General Chemistry and Laboratory I Laboratory 4. Introduction to Chemical Reactions (based in part on Small Scale Chemistry methodology as described in Chemtrek by Stephen Thompson at Colorado

More information

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution , drinking water, 8359 DOC316.53.01239 Direct Measurement ISE Method Method 8359 0.04 to 4.00 mg/l NO 3 N TISAB Solution Scope and Application: Drinking water Test preparation How to use instrument-specific

More information

1) A ph/mv meter or an ion meter, either line operated or portable.

1) A ph/mv meter or an ion meter, either line operated or portable. COLE-PARMER Sodium Ion Electrodes Instruction Manual GENERAL INSTRUCTIONS The Cole-Parmer Sodium Ion Electrodes are used to quickly, simply, accurately, and economically measure sodium ion concentrations

More information

Chapter 18 Electrochemistry. Electrochemical Cells

Chapter 18 Electrochemistry. Electrochemical Cells Chapter 18 Electrochemistry Chapter 18 1 Electrochemical Cells Electrochemical Cells are of two basic types: Galvanic Cells a spontaneous chemical reaction generates an electric current Electrolytic Cells

More information

The Cole-Parmer Ammonium Ion Electrode is used to quickly, simply, accurately, and economically measure ammonium ions in aqueous solutions.

The Cole-Parmer Ammonium Ion Electrode is used to quickly, simply, accurately, and economically measure ammonium ions in aqueous solutions. Cole-Parmer Ammonium Ion Electrodes Instruction Manual GENERAL INSTRUCTIONS Introduction The Cole-Parmer Ammonium Ion Electrode is used to quickly, simply, accurately, and economically measure ammonium

More information

Section B: Some Essential Background Chemistry

Section B: Some Essential Background Chemistry Section B: Some Essential Background Chemistry Soluble and insoluble salts The importance of knowing whether a salt is soluble or insoluble in water You will remember that acids react with carbonates to

More information

Electrodes are normally made out of inert (unreactive) materials. Graphite and platinum are common electrode materials.

Electrodes are normally made out of inert (unreactive) materials. Graphite and platinum are common electrode materials. Electrolysis Electrolysis is using an electric current to break up an ionic compound to form elements. Covalent compounds can t be split up by electrolysis. Terms used in electrolysis: Electrolyte - the

More information

Sodium Chloride - Analytical Standard

Sodium Chloride - Analytical Standard Sodium Chloride - Analytical Standard Determination of Arsenic Former numbering: ECSS/CN 312-1982 & ESPA/CN-E-105-1994 1. SCOPE AND FIELD OF APPLICATION The present EuSalt Analytical Standard describes

More information

Unit - 3 ELECTROCHEMISTRY VSA QUESTIONS (1 - MARK QUESTIONS) 3. Mention the purpose of salt-bridge placed between two half-cells of a galvanic cell?

Unit - 3 ELECTROCHEMISTRY VSA QUESTIONS (1 - MARK QUESTIONS) 3. Mention the purpose of salt-bridge placed between two half-cells of a galvanic cell? Unit - 3 ELECTROCHEMISTRY 1. What is a galvanic cell? VSA QUESTIONS (1 - MARK QUESTIONS) 2. Give the cell representation for Daniell Cell. 3. Mention the purpose of salt-bridge placed between two half-cells

More information

COLE-PARMER LABORATORY AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER LABORATORY AMMONIUM ION ELECTRODE INSTRUCTION MANUAL COLE-PARMER LABORATORY AMMONIUM ION ELECTRODE INSTRUCTION MANUAL Cole-Parmer Instrument Company (800)323-4340 Fax:(847)247-2929 625 East Bunker Court, Vernon Hills, Illinois 60061 http://www.coleparmer.com

More information

4.4. Revision Checklist: Chemical Changes

4.4. Revision Checklist: Chemical Changes 4.4. Revision Checklist: Chemical Changes Reactivity of metals When metals react with other substances the metal atoms form positive ions. The reactivity of a metal is related to its tendency to form positive

More information

Chapter 3: Solution Chemistry (For best results when printing these notes, use the pdf version of this file)

Chapter 3: Solution Chemistry (For best results when printing these notes, use the pdf version of this file) Chapter 3: Solution Chemistry (For best results when printing these notes, use the pdf version of this file) Section 3.1: Solubility Rules (For Ionic Compounds in Water) Section 3.1.1: Introduction Solubility

More information

C = concentration as ppm sulfide V t = volume of titrant at endpoint V s = volume of standard used (10 ml)

C = concentration as ppm sulfide V t = volume of titrant at endpoint V s = volume of standard used (10 ml) GENERAL INSTRUCTIONS Introduction The Van London-pHoenix Silver/Sulfide Ion Electrode is used to measure silver or sulfide ions in aqueous solutions. The two ions are virtually never present in solution

More information

Properties of Compounds

Properties of Compounds Chapter 6. Properties of Compounds Comparing properties of elements and compounds Compounds are formed when elements combine together in fixed proportions. The compound formed will often have properties

More information

Net Ionic Equations. Making Sense of Chemical Reactions

Net Ionic Equations. Making Sense of Chemical Reactions Making Sense of Chemical Reactions Now that you have mastered writing balanced chemical equations it is time to take a deeper look at what is really taking place chemically in each reaction. There are

More information

NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC

NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC OPERATING MANUAL ba15362e03 10/2014 NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC NITRATE SENSITIVE ELECTRODE NO 500 NO 800 Note The latest version of the present operating manual can be found on the Internet

More information

Ch. 14. ELECTRODES AND POTENTIOMETRY

Ch. 14. ELECTRODES AND POTENTIOMETRY Ch. 14. ELECTRODES AND POTENTIOMETRY 14.1 Analytical chemists design electrodes (voltage sensitive to conc. change) galvanic cells ion-selective electrodes ion-sensing field effect transistors potentiometry

More information

Chemistry 20 Lesson 17 Solubility

Chemistry 20 Lesson 17 Solubility Chemistry 20 Lesson 17 Solubility The ability of one compound to dissolve in another compound is called solubility. The term solubility can be used in two senses, qualitatively and quantitatively. Qualitatively,

More information

#13 Electrochemical Cells

#13 Electrochemical Cells #13 Electrochemical Cells If a copper strip is placed in a solution of copper ions, one of the following reactions may occur: Cu 2+ + 2e - Cu Cu Cu 2+ + 2e - The electrical potential that would be developed

More information

READING A. INTRODUCTION CHE425L POTENTIOMETRY WITH K + ION-SELECTIVE ELECTRODE. Skoog, Holler and Crouch: Chapter 23 and Appendix 3.

READING A. INTRODUCTION CHE425L POTENTIOMETRY WITH K + ION-SELECTIVE ELECTRODE. Skoog, Holler and Crouch: Chapter 23 and Appendix 3. CHE425L POTENTIOMETRY WITH K + ION-SELECTIVE ELECTRODE READING Skoog, Holler and Crouch: Chapter 23 and Appendix 3. A. INTRODUCTION Potentiometry is a static electroanalytical method in which the potential

More information

CHM 213 (INORGANIC CHEMISTRY): Applications of Standard Reduction Potentials. Compiled by. Dr. A.O. Oladebeye

CHM 213 (INORGANIC CHEMISTRY): Applications of Standard Reduction Potentials. Compiled by. Dr. A.O. Oladebeye CHM 213 (INORGANIC CHEMISTRY): Applications of Standard Reduction Potentials Compiled by Dr. A.O. Oladebeye Department of Chemistry University of Medical Sciences, Ondo, Nigeria Electrochemical Cell Electrochemical

More information

ORGANIZATION OF THE SCHEME FOR QUALITATIVE ANALYSIS

ORGANIZATION OF THE SCHEME FOR QUALITATIVE ANALYSIS : Precipitation and Separation of Group I Ions PURPOSE To provide an overview of a general scheme for separating and identifying ten cations. To introduce the laboratory techniques used in qualitative

More information

COLE-PARMER REPLACEABLE MEMBRANE CALCIUM ION ELECTRODES INSTRUCTION MANUAL

COLE-PARMER REPLACEABLE MEMBRANE CALCIUM ION ELECTRODES INSTRUCTION MANUAL COLE-PARMER REPLACEABLE MEMBRANE CALCIUM ION ELECTRODES INSTRUCTION MANUAL GENERAL INSTRUCTIONS Introduction The Cole-Parmer Calcium Ion Electrodes are used to quickly, simply, accurately, and economically

More information

4.4. Revision Checklist: Chemical Changes

4.4. Revision Checklist: Chemical Changes 4.4. Revision Checklist: Chemical Changes Reactivity of metals When metals react with other substances the metal atoms form positive ions. The reactivity of a metal is related to its tendency to form positive

More information

Part 01 - Notes: Reactions & Classification

Part 01 - Notes: Reactions & Classification Objectives: Identify, define, and explain: combination reaction, synthesis reaction, decomposition reaction, single replacement reaction, double replacement reaction, combustion reaction, rapid oxidation,

More information

Chemistry 213. Electrochemistry

Chemistry 213. Electrochemistry Chemistry 213 Electrochemistry Part A: Electrochemical Cells Objective Oxidation/reduction reactions find their most important use in the construction of voltaic cells (chemical batteries). In this experiment,

More information

Year 8 Chemistry Knowledge Organiser Topic 1: Periodic Table

Year 8 Chemistry Knowledge Organiser Topic 1: Periodic Table KPI 1.1: Identify, with reasons, differences between atoms, elements and compounds Key Terms Element Mixture Compound Elements Definitions A substance that contains only one type of atom A substance that

More information

EXPERIMENTS. Testing products of combustion: Reducing Copper(III) Oxide to Copper. Page 4

EXPERIMENTS. Testing products of combustion: Reducing Copper(III) Oxide to Copper. Page 4 APPARATUS Page 2 APPARATUS Page 3 Reducing Copper(III) Oxide to Copper EXPERIMENTS Page 4 Testing products of combustion: EXPERIMENTS Showing that oxygen and water is needed for rusting iron Page 5 Showing

More information

Draw one line from each solution to the ph value of the solution. Solution ph value of the solution

Draw one line from each solution to the ph value of the solution. Solution ph value of the solution 1 The ph scale is a measure of the acidity or alkalinity of a solution. (a) Draw one line from each solution to the ph value of the solution. Solution ph value of the solution 5 Acid 7 9 Neutral 11 13

More information

Chemistry: The Central Science. Chapter 20: Electrochemistry

Chemistry: The Central Science. Chapter 20: Electrochemistry Chemistry: The Central Science Chapter 20: Electrochemistry Redox reaction power batteries Electrochemistry is the study of the relationships between electricity and chemical reactions o It includes the

More information

1.11 Redox Equilibria

1.11 Redox Equilibria 1.11 Redox Equilibria Electrochemical cells Electron flow A cell has two half cells. The two half cells have to be connected with a salt bridge. Simple half cells will consist of a metal (acts an electrode)

More information

Final NYB Fall 2009 Condensed Version (Working Spaces Removed)

Final NYB Fall 2009 Condensed Version (Working Spaces Removed) Please Note: 1. There was a set of 15 multiple choice questions that were present on this exam, but have not been reproduced for the practice version. It would have taken approximately 10-30 minutes to

More information

5072 CHEMISTRY (NEW PAPERS WITH SPA) BASIC TECHNIQUES 5067 CHEMISTRY (NEW PAPERS WITH PRACTICAL EXAM) BASIC TECHNIQUES

5072 CHEMISTRY (NEW PAPERS WITH SPA) BASIC TECHNIQUES 5067 CHEMISTRY (NEW PAPERS WITH PRACTICAL EXAM) BASIC TECHNIQUES 5072 CHEMISTRY (NEW PAPERS WITH SPA) BASIC TECHNIQUES 5067 CHEMISTRY (NEW PAPERS WITH PRACTICAL EXAM) BASIC TECHNIQUES LEARNING OUTCOMES a) Be able to write formulae of simple compounds b) Be able to write

More information

Electrochemistry. Part I: Electrochemical Activity from Chemical Reactions. Part II. Electrochemical activity from cell potentials.

Electrochemistry. Part I: Electrochemical Activity from Chemical Reactions. Part II. Electrochemical activity from cell potentials. Electrochemistry Introduction: Redox (oxidation-reduction) reactions will be used to determine the relative electrochemical reactivity of 5 metals. In Part I of the experiment, you will determine the activity

More information

NCERT. [H O] Since water is in large excess, its concentration can be assumed to be constant and combining it with K provides a new constant K w

NCERT. [H O] Since water is in large excess, its concentration can be assumed to be constant and combining it with K provides a new constant K w UNIT-5 PH AND PH CHANGE IN AQUEOUS SOLUTIONS YOU have already performed experiments on dynamic equilibrium between unionised salt and the ions produced by it on dissolving in a solvent. In this unit we

More information

Solubility Rules and Net Ionic Equations

Solubility Rules and Net Ionic Equations Solubility Rules and Net Ionic Equations Why? Solubility of a salt depends upon the type of ions in the salt. Some salts are soluble in water and others are not. When two soluble salts are mixed together

More information

Set 4 Marking Scheme: Acid Bases & Salts 2010

Set 4 Marking Scheme: Acid Bases & Salts 2010 Set 4 Marking Scheme: Acid Bases & Salts 00 ACID AND BASES PAPER : STRUCTURE (a) Neutralisation KOH + H SO 4 K SO 4 + H O Correct formulae of reactants and products Balanced equation i. H +, OH -, K +

More information

The Oakton Cadmium Ion Electrodes are used to quickly, simply, accurately, and economically measure cadmium ions in aqueous solutions.

The Oakton Cadmium Ion Electrodes are used to quickly, simply, accurately, and economically measure cadmium ions in aqueous solutions. OAKTON Cadmium Ion Electrodes Instruction Manual GENERAL INSTRUCTIONS Introduction The Oakton Cadmium Ion Electrodes are used to quickly, simply, accurately, and economically measure cadmium ions in aqueous

More information

COLE-PARMER LABORATORY CYANIDE ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER LABORATORY CYANIDE ION ELECTRODE INSTRUCTION MANUAL COLE-PARMER LABORATORY CYANIDE ION ELECTRODE INSTRUCTION MANUAL Cole-Parmer Instrument Company (800)323-4340 Fax:(847)247-2929 625 East Bunker Court, Vernon Hills, Illinois 60061 http://www.coleparmer.com

More information

CSUS Department of Chemistry Experiment 3 Chem.1A

CSUS Department of Chemistry Experiment 3 Chem.1A Experiment 3: Reactions in Aqueous Solutions: Pre lab Name: 10 points Due at the beginning of lab. Section: 1. Precipitation Reactions a. On the reverse side of this page or on a separate piece of paper,

More information

John Abbott College Department of Chemistry Chemistry 202-NYB-05 Sample Final Exam

John Abbott College Department of Chemistry Chemistry 202-NYB-05 Sample Final Exam John Abbott College Department of Chemistry Chemistry 202-NYB-05 Sample Final Exam Please Note: 1. Available space for answers has been removed from some questions to conserve space. 2. The questions begin

More information

Electro Analytical Methods

Electro Analytical Methods CH 2252 Instrumental Methods of Analysis Unit II Electro Analytical Methods Dr. M. Subramanian Associate Professor Department of Chemical Engineering Sri Sivasubramaniya Nadar College of Engineering Kalavakkam

More information

Electrochemistry. Redox reactions. Half Reactions. Nernst Equation Ion selective electrodes

Electrochemistry. Redox reactions. Half Reactions. Nernst Equation Ion selective electrodes Electrochemistry Nernst Equation Ion selective electrodes Redox reactions oxidation - loss of electrons M n+ M n+1 + e - M is oxidized - reducing agent reduction - gain of electrons N n+ + e - N n-1 N

More information

Analysis of cations and anions by Ion- Selective Electrodes (ISEs)

Analysis of cations and anions by Ion- Selective Electrodes (ISEs) Analysis of cations and anions by Ion- Selective Electrodes (ISEs) Purpose: The purpose of this assignment is to introduce potentiometric measurements of ionic species by ion selective electrodes (ISEs)

More information

ELECTROCHEMISTRY. these are systems involving oxidation or reduction there are several types METALS IN CONTACT WITH SOLUTIONS OF THEIR IONS

ELECTROCHEMISTRY. these are systems involving oxidation or reduction there are several types METALS IN CONTACT WITH SOLUTIONS OF THEIR IONS Electrochemistry 1 ELECTROCHEMISTRY REDOX Reduction gain of electrons Cu 2+ (aq) + 2e > Cu(s) Oxidation removal of electrons Zn(s) > Zn 2+ (aq) + 2e HALF CELLS these are systems involving oxidation or

More information

COLE-PARMER LABORATORY CUPRIC ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER LABORATORY CUPRIC ION ELECTRODE INSTRUCTION MANUAL COLE-PARMER LABORATORY CUPRIC ION ELECTRODE INSTRUCTION MANUAL Cole-Parmer Instrument Company (800)323-4340 Fax:(847)247-2929 625 East Bunker Court, Vernon Hills, Illinois 60061 http://www.coleparmer.com

More information

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA , 10255 DOC316.53.01322 Direct Measurement ISE Method Method 10255 3.55 g/l to 35 g/l Cl Powder Pillow ISA Scope and Application: For the determination of high concentrations (1 M) of chloride in brine

More information

Unit 4: Chemical Changes (Higher Content)

Unit 4: Chemical Changes (Higher Content) Metals react with oxygen to produce metal oxides. E.g. Copper + Oxygen > Copper Oxide The reactions are oxidation reactions because the metals gain oxygen. Reactivity of Metals Metal Extraction Metals

More information

COLE-PARMER LABORATORY CALCIUM ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER LABORATORY CALCIUM ION ELECTRODE INSTRUCTION MANUAL COLE-PARMER LABORATORY CALCIUM ION ELECTRODE INSTRUCTION MANUAL Cole-Parmer Instrument Company (800)323-4340 Fax:(847)247-2929 625 East Bunker Court, Vernon Hills, Illinois 60061 http://www.coleparmer.com

More information

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA. Background

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA. Background POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA Background In this experiment, students will familiarize themselves with potentiometric titration, practice using the first derivative to find the equivalence

More information

Year 10 Chemistry. Practice questions. Topics

Year 10 Chemistry. Practice questions. Topics Year 10 Chemistry Practice questions Topics 1 Group 1 2 Group 7 3 Reactivity series 4 Air and Water 5 Rates of reaction 6 Electrolysis 7 Acids, Alkali and Salts Objective: Evaluate group 1 & 7 reactivity

More information

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Subsidiary Level and Advanced Level CHEMISTRY 9701/03

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Subsidiary Level and Advanced Level CHEMISTRY 9701/03 Centre Number Candidate Number Name UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Subsidiary Level and Advanced Level CHEMISTRY 9701/03 Paper 3 Practical

More information

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT METHOD 9040B ph ELECTROMETRIC MEASUREMENT 1.0 SCOPE AND APPLICATION 1.1 Method 9040 is used to measure the ph of aqueous wastes and those multiphase wastes where the aqueous phase constitutes at least

More information

CHEMISTRY. SCIENCE Paper 2

CHEMISTRY. SCIENCE Paper 2 CHEMISTRY SCIENCE Paper 2 (Two hours) Answers to this Paper must be written on the paper provided separately. You will not be allowed to write during the first 15 minutes. This time is to be spent in reading

More information

EXPERIMENT 7 Precipitation and Complex Formation

EXPERIMENT 7 Precipitation and Complex Formation EXPERIMENT 7 Precipitation and Complex Formation Introduction Precipitation is the formation of a solid in a solution as the result of either a chemical reaction, or supersaturating a solution with a salt

More information

4.4: Solubility and Ionic Equations

4.4: Solubility and Ionic Equations 4.4: Solubility and Ionic Equations Solubility Curves Graphs of solubility (maximum concentration) against temperature allow quick and easy reference, and are very useful for a wide variety of questions

More information

Form 4 Chapter 7: Acid and Bases

Form 4 Chapter 7: Acid and Bases Form 4 Chapter 7: Acid and Bases The ph Scale Properties Acids Alkalis Physical. Substances that ionized in water to produce hydrogen ions.. Sour taste.. Turn blue litmus paper red. 4. Give a ph value

More information

DOUBLE DISPLACEMENT REACTIONS. Double your pleasure, double your fun

DOUBLE DISPLACEMENT REACTIONS. Double your pleasure, double your fun DOUBLE DISPLACEMENT REACTIONS Double your pleasure, double your fun Industrial processes produce unwanted by-products. Dissolved toxic metal ions-copper, mercury, and cadmium-are common leftovers in the

More information

S4 CHEMISTRY SUMMARY NOTES

S4 CHEMISTRY SUMMARY NOTES S4 CHEMISTRY SUMMARY NOTES 1. The Mole One mole of a substance = GRAM FORMULA MASS e.g. H 2 SO 4 RAM from databook pg.7 2H 2 x 1 = 2 1S 1 x 32 = 32 4O 4 x 16 = 64 98g Mass = number of moles x Mass of 1

More information

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about Electrochemistry LEC 06 What you can learn about Galvanic cell Types of electrodes Nernst equation Potentiometry Principle and tasks The cell voltage and the Galvani voltage of the electrodes of an galvanic

More information

Chem 321 Lecture 17 - Potentiometry 10/24/13

Chem 321 Lecture 17 - Potentiometry 10/24/13 Student Learning Objectives Chem 321 Lecture 17 - Potentiometry 10/24/13 Electrodes The cell described in the potentiometric chloride titration (see 10/22/13 posting) consists of a Ag/AgCl reference electrode

More information

NH 3 -selective electrodes

NH 3 -selective electrodes NH 3 -selective electrodes Manual 8.109.8031EN Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com NH 3 -selective electrodes Manual 8.109.8031EN

More information

The electrolysis of sodium chloride solution produces useful substances. covalent ionic non-metallic

The electrolysis of sodium chloride solution produces useful substances. covalent ionic non-metallic 1 The electrolysis of sodium chloride solution produces useful substances. (a) (i) Choose a word from the box to complete the sentence. covalent ionic non-metallic Electrolysis takes place when electricity

More information

(i) The atomic number of an atom is the number of... (ii) The mass number of an atom is the number of...

(i) The atomic number of an atom is the number of... (ii) The mass number of an atom is the number of... C2 Essential Questions Atomic Structure Q1.This question is about atomic structure and elements. (a) Complete the sentences. (i) The atomic number of an atom is the number of... (ii) The mass number of

More information

Exercise 6: Determination of Hardness of Water

Exercise 6: Determination of Hardness of Water Fundamentals of Analytical Chemistry, CHC014011L Exercise 6: Determination of Hardness of Water Introduction: Hardness in water is generally caused by the presence of dissolved calcium and magnesium carbonates

More information

Chapter 13 POTENTIOMETRIC ELECTRODES AND POTENTIOMETRY

Chapter 13 POTENTIOMETRIC ELECTRODES AND POTENTIOMETRY Chapter 13 POTENTIOMETRIC ELECTRODES AND POTENTIOMETRY POTENTIOMETRIC ELECTRODES AND POTENTIOMETRY Ch.13 In this chapter Understand the concept of the various types of electrodes that can be used for measuring

More information

perfection Guidebook perfection Combination Fluoride Electrode Successful Ion Measurement

perfection Guidebook perfection Combination Fluoride Electrode Successful Ion Measurement perfection Guidebook perfection Combination Fluoride Electrode Successful Ion Measurement Contents Table of Contents 1. Introduction 1 2. Required Equipment 2 3. Electrode and Measurement Setup 4 Electrode

More information

Lesson on Electrolysis

Lesson on Electrolysis Lesson on Electrolysis This lesson package includes a lesson plan, a worksheet for students, and teachers notes on the worksheet. Activity Lesson 1 (50 min-2 Period lesson) Teacher explains (page 1 to

More information

To determine relative oxidizing and reducing strengths of a series of metals and ions.

To determine relative oxidizing and reducing strengths of a series of metals and ions. Redox Reactions PURPOSE To determine relative oxidizing and reducing strengths of a series of metals and ions. GOALS 1 To explore the relative oxidizing and reducing strengths of different metals. 2 To

More information

Electrochemistry. To use principles of electrochemistry to understand the properties of electrochemical cells and electrolysis.

Electrochemistry. To use principles of electrochemistry to understand the properties of electrochemical cells and electrolysis. Electrochemistry Objectives: To use principles of electrochemistry to understand the properties of electrochemical cells and electrolysis. Background: Part I: Galvanic Cells: A Galvanic cell is a device

More information

Naming salts. Metal Acid Salt. Sodium hydroxide reacts with Hydrochloric acid to make Sodium chloride

Naming salts. Metal Acid Salt. Sodium hydroxide reacts with Hydrochloric acid to make Sodium chloride Naming salts A salt is any compound formed by the neutralisation of an acid by a base. The name of a salt has two parts. The first part comes from the metal, metal oxide or metal carbonate. The second

More information

( 1 ) Concept of acid / base

( 1 ) Concept of acid / base Section 6.2 Ionic Equilibrium Unit 628 ( 1 ) Concept of acid / base The best definition of acids and bases is that proposed by T.M. Lowry and also, independently by J.N. Bronsted in 1923. BronstedLowry

More information

The design and operational theory of ph electrodes is a very complex subject, explored only briefly here. What is important to understand is that thes

The design and operational theory of ph electrodes is a very complex subject, explored only briefly here. What is important to understand is that thes ph measurement A very important measurement in many liquid chemical processes (industrial, pharmaceutical, manufacturing, food production, etc.) is that of ph: the measurement of hydrogen ion concentration

More information

Chemistry 12 Solubility Equilibrium I. Name: Date: Block: 1. Solutions Vocab & Calculations 2. Predicting Solubility 3.

Chemistry 12 Solubility Equilibrium I. Name: Date: Block: 1. Solutions Vocab & Calculations 2. Predicting Solubility 3. Chemistry 12 Solubility Equilibrium I Name: Date: Block: 1. Solutions Vocab & Calculations 2. Predicting Solubility 3. Writing Equations Solutions Vocab & Calculations What is a solution? A homogenous

More information

Lab #14: Electrochemical Cells

Lab #14: Electrochemical Cells Lab #14: Electrochemical Cells Objectives: 1. To understand the nature of electrochemical cells. 2. To construct a table listing the reduction potentials of a series of metal ions, in order of ease of

More information

CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education Centre Number Candidate Number Name CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education CHEMISTRY 0620/05 Paper 5 Practical Test Candidates answer on the Question

More information

AP Chemistry Unit #4. Types of Chemical Reactions & Solution Stoichiometry

AP Chemistry Unit #4. Types of Chemical Reactions & Solution Stoichiometry AP Chemistry Unit #4 Chapter 4 Zumdahl & Zumdahl Types of Chemical Reactions & Solution Stoichiometry Students should be able to: Predict to some extent whether a substance will be a strong electrolyte,

More information