Too Polar for Reversed Phase What Do You Do?

Similar documents
(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

LC and LC/MS Column Selection Flow Chart

Does one-size-fit-all?

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Choosing Columns and Conditions for the Best Peak Shape

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

Packings for HPLC. Packings for HPLC

William E. Barber, Ph.D. Applications Chemist October

Analyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

State-of-the-art C18 HPLC Columns

LC Columns with Liquid Separation Cell Technology

penta-hilic UHPLC COLUMNS

New Product Update. HPLC Columns

A Look at Agilent HPLC Columns Choices

High Resolution Fast LC

Part 2. Overview of HPLC Media

penta-hilic UHPLC COLUMNS

The Theory of HPLC. Ion Pair Chromatography

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

How proteins separate on reverse-phase HPLC

Analysis - HPLC A.136. Primesep 5 µm columns B.136

HPLC Method Development with Eclipse Plus: Standard Practices and New Columns. Agilent Technologies

Acclaim Mixed-Mode WCX-1

Inertsil Technical Library

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

HPLC Method Development: Standard Practices and New Columns

Optimisil HPLC & UPLC Column catalogue

Hamilton. Reversed-Phase Anion Exchange Cation Exchange Ion Exclusion

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Small Molecule Selectivity Sampler

for Acclaim Mixed-Mode HILIC-1 Column

Reversed Phase Solvents

Liquid Chromatography

HILIC Method Development in a Few Simple Steps

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Advantages of polymerbased. an alternative for ODS

ION PAIRING REAGENTS AND BUFFERS

HPLC Separation Fundamentals. Ed Kim Application Engineer Agilent Technologies, Inc January 14, 2009

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

for Acclaim Mixed-Mode WCX-1

Alltech Alltima HP Introduction

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Cation Exchange HPLC Columns

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Fast Separation of Vastly Different Compounds by Isocratic HPLC

UPLC Method Development and Validation

It s hot! ZIC -chilic

Technical Guide Thermo Scientific Syncronis HPLC Columns

A Look at Column Choices. Ed Kim Application Engineer Agilent Technologies, Inc February 12, 2009

1.7µm Fortis UHPLC Columns

InertSustainSwift C8

State - of - the -art C18 HPLC Columns

The Theory of HPLC. Normal Phase (Absorption) Chromatography

1.7 m Fortis UHPLC Columns

LC Technical Information

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

HPLC Method Development: Standard Practices and New Columns. Agilent Technologies February 2007

Agilent LC & LC-MS Cannabis Testing

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

1. Ion exchange chromatography

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

The Evolving HPLC Column Packings

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Multi-mode Separations Using Zirconiabased Stationary Phases

8. Methods in Developing Mobile Phase Condition for C18 Column

Acclaim HILIC-10 Columns

Method Development with ZirChrom's Ion Exchange Phases

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

The column name corresponds to ph value of the mobile phase where acid residue on the column switches from ionize form to neutral one.

Method Development Kits

Hillel K. Brandes and David S. Bell Supelco, Liquid Separations, Bellefonte PA T GIH

Comparison of different aqueous mobile phase HPLC techniques

The new Agilent 1290 Infinity Quaternary LC

for Acclaim Trinity TM P1

Saccharides and Organic Acids

SHARC Separation separation Technology. LC Column with Hydrogen Bonding Based Separation. 65 E. Palatine Rd., Suite 221. SIELC Technologies, Inc.

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Thermo Scientific HILIC Separations Technical Guide HILIC. Separations. A Practical Guide to HILIC Mechanisms, Method Development and Troubleshooting

Trends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles

New To HPLC Avoiding Beginner Pitfalls. Rita Steed LC Columns Application Engineer April 24, 2013

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC

Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

Transcription:

Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1

C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer with 5 to 100% organic Some very polar acids and bases not well retained Increase retention with less organic Performance of C18 columns under highly aqueous conditions not always robust Page 2

Pore Dewetting or Phase Collapse Alkyl phases such as C8 or C18 can exhibit poor retention or reproducibility of retention in low organic mobile phases Phenomenon known as pore dewetting or phase collapse Onset can be unpredictable A method robustness issue often mistaken as a column or lot issue See Przybyciel and Majors, LCGC 20(6), 516-523 (2002). Page 3

What Do You Do? Adjust method conditions Ion-pair chromatography Alternate column choice (polar modified) Normal phase HILIC Ligand exchange

Adjust Method Conditions Reversed-phase methods often use low ph Basic compounds will be charged Adjusting ph up (>8) will generally increase retention High ph can damage many silica based columns Choose ZORBAX Extend-C18 (to 11.5) or PLRP-S (to 14) Page 5

Extend-C18 Bidentate structure Double endcapped ph 2 11.5 (at 40 C) Page 6

Basic Antihistamines at High ph Page 7

Ion-Pair Chromatography Similar to reversed-phase, but an ion-pairing reagent is added to the mobile phase Alkyl sulfonate - + Amine Non-polar stationary phase Non-polar alkyl chain will adsorb into the non-polar stationary phase Polar part of the ion-pairing reagent will stick-out into the mobile phase Page 8

Ion-Pair Chromatography Similar to reversed-phase, but an ion-pairing reagent is added to the mobile phase Quaternary amine + - Carboxylic acid Non-polar stationary phase Non-polar alkyl chain will adsorb into the non-polar stationary phase Polar part of the ion-pairing reagent will stick-out into the mobile phase Page 9

Some Common Ion-Pairing Reagents Pairs with Cations Pairs with Anions CH 3 -(CH 2 ) n Alkyl sulfonates R CH R 3 -(CH 2 ) n R Quaternary amines Heptafluorobutyric acid (HFBA) Page 10

Ion-Pair Parameters IP reagent Longer alkyl chain--more readily adsorbed by stationary phase Choose alkyl length which gives best separation (more retention of amines with octanesulfonate than hexanesulfonate) Select cationic ion-pairing reagent for anions (e.g., acids) Select anionic ion-pairing reagent for cations (e.g., amines) Not both together IP Concentration ph Increase retention with increasing IP concentration Increase concentration with %B - non-linear adsorption Buffer concentration Choice of organic modifier %B Temperature Page 11

Ion-Pair Chromatography Suggested Experimental Conditions Column: C8 or C18 Mobile Phase: Organic often methanol Aqueous - Buffered with appropriate IP reagent Temperature controlled between 35 and 60 C Cations bases Buffer: 25 50 mm phosphate, ph 2-3 IP reagent: 10-100 mm hexane sulfonate Anions acids Buffer: 25 50 mm phosphate, ph 6 7 IP reagent: 10-40 mm tetrabutyl ammonium phosphate Page 12

Ion-Pair Chromatography Issues Higher level of complexity than RP, so generally chosen only if needed Requires careful control of IP reagent, ph, temperature Gradient methods are more difficult than RP Equilibration is much slower than RP Column dedicated to IP IP-reagent in the injection solvent Page 13

Amino Acids by Ion-Pair ZORBAX SB-C18 RRHT, 1.8 µm, 3 x 50 mm, 25 C, 1 µl inj 0.4 ml/min A: water/ 0.5 % FA + 0.3% HFBA B: ACN/0.5% FA + 0.3% HFBA 0 to 5% B over 5 minutes 5991-0904EN Page 14

Alternative Column Choices Some column phases resist dewetting for use at low organic or 100% aqueous conditions Options include: Phenyl or Phenyl-Hexyl Bonus-RP (polar amide embedded) SB-Aq Page 15

ZORBAX Method Development Kits Page 16

Phenyl Phases ZORBAX options include: Eclipse Plus Phenyl-Hexyl Eclipse XDB-Phenyl StableBond SB-Phenyl Poroshell 120 Phenyl-Hexyl Slight selectivity differences Choice of mobile phase important Page 17

Catecholamines on Phenyl Phases 5990-3616EN Page 18

Catecholamines by Ion-Pair 5968-2966E Page 19

Catecholamines on Phenyl Phases 5990-3616EN Page 20

Aliphatic Acids 5990-3616EN Page 21

Nucleobases and Nucleosides 1. Cytosine 2. Uracil 3. Cytidine 4. Guanine 5. Uridine 6. Adenine 7. Thymine 8. Guanosine 9. Thymidine 10. Adenosine A: 20 mm ammonium acetate, ph 4.5 B: methanol 1 ml/min, 254 nm Time (min) % B 0 1 4 1 6 50 Page 22

ZORBAX Bonus-RP Phase Alkyl phase Polar group embedded Triple Endcapped ph 2 9 Page 23

Hair Dye Analysis on Bonus-RP 5991-1289EN Page 24

ZORBAX SB-Aq Phase 5991-1992EN Page 25

Normal Phase Polar stationary phase: Silica Cyano Amine Diol (Relatively) Non-polar mobile phase: Typical solvent systems hexane/methylene chloride, hexane/ethyl acetate, methylene chloride/methanol, hexane/isopropanol, etc. Page 26

Normal Phase Very polar compounds will be well retained Reproducibility often an issue Important to control the amount of water in MP with silica column Slow equilibration of silica columns Tailing peaks Cyano phase equilibration faster, gradients possible Page 27

HILIC Hydrophilic Interaction Chromatography Polar stationary phase: Silica Amine Amide Diol Page 28

HILIC Hydrophilic Interaction Chromatography Polar stationary phase: Silica Amine Amide Diol Polar mobile phase: Water is the strong solvent THF<acetone<ACN<iPrOH<EtOH<MeOH<water Typically ACN/water Buffer controls ionization of analyte and stationary phase Typically ammonium acetate or ammonium formate Page 29

How Does HILIC Work on Silica? Water layer must be adsorbed onto the stationary phase Polar analytes partition in and out of this adsorbed layer Charged polar analytes can also ion exchange with charged silica particles, i.e., cation exchange with amines Combination of mechanisms drives retention in HILIC Retention/elution is from least to most polar opposite of reversed-phase LC HILIC offers more retention than reversed-phase for very polar bases 30 June 21, 2013

HILIC Advantages Good peak shape for basic compounds where RP may give tailing and/or low efficiency Low viscosity mobile phases with high organic content allow the use of higher flow rates and/or long columns Enhanced detection sensitivity with MS Efficient spraying and desolvation in electrospray MS As much as 3X sensitivity Can directly inject ACN extracts from C18 SPE cartridges 31 June 21, 2013

HILIC Challenges Slower equilibration than RPLC Particularly true for bare silica columns Longer to equilibrate initially Longer to equilibrate when mobile phase changes for gradients or method development are required Peak distortion with mobile phase / sample solvent mismatch Mechanism not well understood Page 32

Typical Conditions Silica column (ZORBAX Rx-SIL, HILIC Plus, Poroshell 120 HILIC) Water (at least 2-3%, ~ 25%)/ACN Buffer (e.g., ammonium acetate) ph control, if necessary Page 33

Equilibrate from high aqueous to low Critical factor when changing mobile phases ZORBAX Rx-Sil, 2.1 x 150, 5um mau 250 Equilibrating 200 from 80 to 90% 150 ACN acn works 100 DAD1 A, Sig=254,4 Ref=360,100 (E:\HILIC PYRIMIDINES\BASES000021.D) A: 25mM ammonium acetate with 2.5 mm ammonium formate B: acetonitrile 10:90 A:B Flow : 0.1 ml/min Temp: 25 C Detection: UV 254nm,4, ref=360,100 Inj. Vol 0.5 µl Instrument Quat 1200 Samples: ca. 0.4 mg/ml each in ACN/water 1. thymine 2. Uracil 3. adenine 4. guanine 5. cytosine 50 0 mau 250 2 4 6 8 10 12 14 16 DAD1 A, Sig=254,4 Ref=360,100 (E:\HILIC PYRIMIDINES\BASES000020.D) min 200 Equilibrating from 150 95 to 90% ACN 100 does not work 50 well 0 2 4 6 8 10 12 14 16 min 34 June 21, 2013

HILIC comparison with C18 Page 35

0.824 1.659 3.635 3.970 3.404 HILIC Separation of Catecholamines Poroshell 120 2.1 x 100, 2.7 micron mau 175 DAD1 A, Sig=280,8 Ref=360,100 (CATECHOLAMINE2\MIX1000025.D) Poroshell 120 HILIC 2.1 x 100, 2.7 micron A: 100 mm NH 4 HCO 2 B: Acetonitrile 168 Bar 150 125 Time(min) % B Flow Rate= 0.6 ml/min Initial 97 2.1 x 100 mm 4 85 4.67 85 5 97 6.67 97 100 75 50 1. Dopamine 2. Epinephrine 3. Norepinephrine 25 Approx. 1 mg/ml each in 66:33 DMSO:MeCN 0.5 µl injection 0 2 4 6 8 min

HILIC Separation of B Vitamins 2 3 4 1

HILIC Separation of B Vitamins

HILIC Separation of Sugars ACN/Water: 70:30 ACN/Water: 75:25

Ligand Exchange (Hi-Plex) Used primarily for sugars, sugar alcohols, organic acids Sulfonated polystyrene/divinylbenzene particles Hydrogen form, or Ca, Na, K, Pb Positively charged ion associated with sulfonate Interacts with the slightly negative hydroxyls of sugars (ligand) Size-exclusion mechanism for oligosaccharides

Ligand Exchange (Hi-Plex) Mobile phase is typically water (or dilute acid) Temperature is main variable for adjusting resolution

Sweeteners by Hi-Plex Ca

Organic acids by Hi-Plex H

Temperature Effects with Hi-Plex

Temperature Effects with Hi-Plex

Mobile Phase Effects with Hi-Plex H2SO4

Summary What do you do when your analyte is too polar? Stick with reversed-phase but choose a more polar phase Phenyl, Phenyl-Hexyl, Bonus-RP, SB-Aq Consider HILIC Ion-pair chromatography Consider application specific phases: Carbohydrate Analysis Hi-Plex Page 47