Contents. Charged Particles. Coulomb Interactions Elastic Scattering. Coulomb Interactions - Inelastic Scattering. Bremsstrahlung

Similar documents
EEE4106Z Radiation Interactions & Detection

MEASUREMENT AND DETECTION OF RADIATION

DETECTORS. I. Charged Particle Detectors

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Chapter Seven (Nuclear Detectors)

Nuclear Physics and Astrophysics

Radionuclide Imaging MII Detection of Nuclear Emission

RADIATION DETECTION AND MEASUREMENT

Radiation Detection and Measurement

Radiation Detection and Measurement

APPLIED RADIATION PHYSICS

SCINTILLATION DETECTORS AND PM TUBES

Chapter 4 Scintillation Detectors

Radiation Dose, Biology & Risk

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

Radiation Detectors. How do we detect ionizing radiation? What are these effects? Types of Ionizing Radiation Detectors

PHYS 3446 Lecture #12

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Detection and measurement of gamma-radiation by gammaspectroscopy

The interaction of radiation with matter

Chapter 11: Neutrons detectors

Quality Assurance. Purity control. Polycrystalline Ingots

Particle Energy Loss in Matter

Anwendungen von Radionukliden und Strahlung (FS2011) Radiation Detectors (Week 2, 2 nd part)

Analysis of γ spectrum

Radiation Detection and Measurement

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

Gamma and X-Ray Detection

Radiation (Particle) Detection and Measurement

Unit 2. Instrumentation. Experts Teaching from Practical Experience

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

Chem 481 Lecture Material 3/20/09

Radioactivity. Lecture 6 Detectors and Instrumentation

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

Dosimetry. Sanja Dolanski Babić May, 2018.

08 - Miscellaneous and historical detectors

Sensors and Detectors Part 2

Scintillation Detector

Atoms, Radiation, and Radiation Protection

XRF books: Analytical Chemistry, Kellner/Mermet/Otto/etc. 3 rd year XRF Spectroscopy Dr. Alan Ryder (R222, Physical Chemistry) 2 lectures:

Emphasis on what happens to emitted particle (if no nuclear reaction and MEDIUM (i.e., atomic effects)

Radiation Protection & Radiation Therapy

Photon Instrumentation. First Mexican Particle Accelerator School Guanajuato Oct 6, 2011

Scintillators General Characteristics

ABSORPTION OF BETA AND GAMMA RADIATION

Trace Element Analysis of Geological, Biological & Environmental Materials By Neutron Activation Analysis: An Exposure

Experimental Particle Physics

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples

Particle Energy Loss in Matter

electrons out of, or ionize, material in their paths as they pass. Such radiation is known as

ORTEC. Review of the Physics of Semiconductor Detectors. Interaction of Ionizing Radiation with Semiconductor Detectors. Heavy Charged Particles

Modern Physics Laboratory (Physics 6180/7180)

Alpha-particle Stopping Powers in Air and Argon

Dosimetry of ionizing radiation

Outline. Radiation Interactions. Spurs, Blobs and Short Tracks. Introduction. Radiation Interactions 1

Experimental Particle Physics

Scintillation Detectors

Lecture # 3. Muhammad Irfan Asghar National Centre for Physics. First School on LHC physics

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Waste Characterization

Chapter 18 Radiation Detectors

Chemical Engineering 412

Interaction of particles in matter

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

Chapter Four (Interaction of Radiation with Matter)

Chapter 6: Basic radiation detectors

Lecture 4. Detectors for Ionizing Particles

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Nuclear techniques in solid state research. Manfred Forker

05 - Scintillation detectors

Basic physics Questions

Rad T 290 Worksheet 2

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Radioactivity and Ionizing Radiation

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Last Lecture 1) Silicon tracking detectors 2) Reconstructing track momenta

"Neutron Flux Distribution"

Detection and Measurement of Radiation

Physics 663. Particle Physics Phenomenology. April 23, Physics 663, lecture 4 1

Particle Interactions in Detectors

Experimental Particle Physics

Ionization Detectors. Mostly Gaseous Detectors

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

Physics in Nuclear Medicine

Physics of X-RAY Production

5) Measurement of Nuclear Radiation (1)

III. Energy Deposition in the Detector and Spectrum Formation

Seminar talks. Overall description of CLAS12 (Jefferson Lab) MAPS. Talks on Feb. 6 th, (Contact JR) (Contact TS)

There are three mechanisms by which gamma rays interact with absorber atoms from which two are important for nuclear medicine.

Airo International Research Journal October, 2015 Volume VI, ISSN:

Interaction of Radiation with Matter

Y2 Neutrino Physics (spring term 2017)

Introduction to Radiation Monitoring

Diffraction: spreading of waves around obstacles (EM waves, matter, or sound) Interference: the interaction of waves

Name Date Class NUCLEAR RADIATION. alpha particle beta particle gamma ray

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

Lab KF6: GAMMA SPECTROSCOPY I

Transcription:

Contents Marcel MiGLiERiNi Nuclear Medicine, Radiology and Their Metrological Aspects. Radiation in Medicine. Dosimetry 4. Diagnostics & Therapy 5. Accelerators in Medicine 6. Therapy Planning 7. Nuclear Medicine 8. Radiology 9. MRI 0. Combined Techniques Principles of detection of ionizing radiation interaction of radiation with matter charged particles photons neutrons detection of radiation Detectors of ionizing radiation gas filled detectors detectors of neutrons scintillation detectors semiconductor detectors dosimeters Pulse counting system signal chain basic blocks of a counting system Marcel MiGLiERiNi MMiiii Charged Particles Coulomb Interactions Elastic Scattering heavy particles: p +, d, α, ions light particles: e -, e + interaction with nuclei and/or electrons no energy transfer Coulomb interactions elastic scattering inelastic scattering excitation ionization bremsstrahlung nuclear reactions Cerenkov radiation Marcel MiGLiERiNi MMiiii 3 Marcel MiGLiERiNi MMiiii 4 Coulomb Interactions - Inelastic Scattering Bremsstrahlung excitation ionization high for heavy particles (α) at the end of their trajectory mean linear losses: de NZ dx v ( ze) E kinetic energy N number of nuclei inabsorber Z atomic number of absorber ze electric charge of particle v velocity of particle Marcel MiGLiERiNi MMiiii 5 observed for electrons change in acceleration scattering of moving electrons (e - ) in the electric field of nuclei acceleration ofelectrons (e - ) along a non straight path (synchrotron) radiation losses r ionization losses -i de dx r t = de dx i Eβ.Z = 800 E β maximum energy of β-spectrum in MeV Z atomic number of absorber Marcel MiGLiERiNi MMiiii 6

Nuclear Reactions Cerenkov Radiation direct excitation of a nucleus by (heavy) charged particles (p +, d, α) originates when the velocity of particle in a given medium (water) is higher than the velocity of light blue fluorescence (in a nuclear reactor) electron-positron annihilation ( x 0.5 MeV) 0.5 MeV 0.5 MeV Marcel MiGLiERiNi MMiiii 7 Marcel MiGLiERiNi MMiiii 8 Interactions of Photons Photons Photoelectric Effect electromagnetic interactions but other mechanisms no Coulomb forces (interactions) velocity of photons does not change => absorption, scattering no definition of range (loss of energy per unit length) decrease in beam intensity bound e - E k = h.ν I A ν. + + h A + e h. ν > I h.ν E k I X-rays three independent processes: photoelectric effect (photoeffect) Compton scattering (Compton effect) electron-positron pair production E k kinetic energy of electron h Planck constant ν frequency I binding energy nuclear photoeffect Marcel MiGLiERiNi MMiiii 9 Marcel MiGLiERiNi MMiiii 0 Photons Compton Scattering Photons Pair Production free e - λ = λ - λ = Λ.sin (θ/) Λ = h/m.c A ν. + + h A + e h.ν h.ν h.ν min =.0 MeV = x0.5 MeV pair production e - -e + only at the vicinity of heavy nuclei consecutive e - -e + annihilation 0.5 MeV h. ν >> I 0.5 MeV λ wave length Λ Compton wave length θ angle between original and scattered photon m mass of electron h Planck constant c velocity of light h.ν A ν. + + + h A + e + e h. ν >. m c 0. Marcel MiGLiERiNi MMiiii Marcel MiGLiERiNi MMiiii

Photons Neutrons probability of interaction via: photoelectric effect Compton scattering 00 pair production decrease in photon beam intensity I t ( t) = I e 0. µ. t thickness µ linear attenuation coefficient I 0 intensityof incoming radiation Z - atomic number 0 0.0 0. 0 00 E γ - energy of photons (MeV) Marcel MiGLiERiNi MMiiii 3 80 60 40 0 photoeffect 53 I 6 C Compton scattering pair production interactions via strong forces (~0-3 m) scattering inelastic elastic absorption Marcel MiGLiERiNi MMiiii 4 Neutrons -Absorption Measurement of Radiation absorption radiation capture ofn 0 fission absorption with consequent emission hadron shower All types of radiation, whether directly or indirectly ionizing, interact with the atoms or molecules of the medium through which they traverse and produce: ionization in gaseous media scintillations in certain materials (scintillators) exposure of photographic emulsions decomposition of chemical media heating of a medium in calorimeters damage in crystals (tracks in vapours, gasses) These properties are used in the design and development of various devices for the detection as well as measurement of radiation. Marcel MiGLiERiNi MMiiii 5 Marcel MiGLiERiNi MMiiii 6 Principles of Detection Gas Filled Detectors formation of electron ion pair gas amplification regions: interaction mechanisms: charged particles: e -, e +, p, d, α, heavy ions (A>4) photons: γ, X-rays neutrons secondary ionization (Townsend avalanche) α β I. recombination II. ionization ionisation chambers III. proportional proportional counters IV. limited proportionality V. Geiger-Müller GM counters VI. continuous discharge Marcel MiGLiERiNi MMiiii 7 Marcel MiGLiERiNi MMiiii 8 3

Type of Detectors Ionisation Chamber Ionization chamber type of particle and its energy only strong ionizing particles: α, p, fission fragments, heavy ions detection of neutrons Proportional counters any type of particle (α, β, γ, neutrons) and its energy detection of low energy possible Geiger-Müller counters only number of particles can be detected detection of low-level radiation quenching gas Marcel MiGLiERiNi MMiiii 9 chamber filled with gas (air) small noise current without radiation (gas is insulator) ionization of gas by passing ionizing radiation charge carriers produce a current flow current is proportional to the intensity of radiation Marcel MiGLiERiNi MMiiii 0 Proportional Counter Geiger-Müller Counter much higher electric field than in ionization chamber acceleration of electrons towards the central electrode gain of sufficient energy further ionization by collision gas amplification Marcel MiGLiERiNi MMiiii lower pressure of gas (Ar+CH 4 ) than in ionization chamber high voltage (~ kv) strong gas amplification single particle of radiation gives a pulse Marcel MiGLiERiNi MMiiii Fission chamber slow neutrons 33 U, 35 U, 39 Pu Boron-lined counter Detection of Neutrons working chamber boron lined gamma + neutrons compensated chamber uncoated gamma only net signal proportional to neutrons Compensated Ionization Chamber BF 3 counter He counter 0 5 3 B 5 7 +++ 4 ++ + 0n 3Li + He + e He + n 0 T + 3 Marcel MiGLiERiNi MMiiii 3 p Marcel MiGLiERiNi MMiiii 4 4

Scintillations Scintillators scintillation = emission of visible light principle excitation of electrons from valence to conduction band by incoming radiation without activator states emission of the same photon reabsorption presence of activator non-radiative transition emission of a scintillation photon emission of a photon with lower energy no absorption occurs energy states of electrons in crystal Scintillators inorganic: NaI(Tl), CsI(Tl), CaI(Na), LiI(Eu), CaF (Eu), ZnS high efficiency for gamma, ms organic: stilbene, anthracene detection of beta, 0 ns plastic: chemicals in plastic matrix detection of fast neutrons possible (contain H ), - ns gaseous: noble gasses Photomultiplier tube ~5 dynodes 80 0 V amplification >0 6 scintillator photocathode dynode anode Marcel MiGLiERiNi MMiiii 5 Marcel MiGLiERiNi MMiiii 6 Scintillation Detectors Semiconductor Detectors Principle: electron hole pair Types of detectors surface barrier detector oxidized high purity Si Ł p-type surface layer diffused junction detector high purity Si wafer with n-type layer (P) Ł p-n junction silicon-lithium drifted detector SiLi formation of n-p junction by Li diffusion germanuim-lithium drifted detector GeLi operated at low temperature hyper pure germanium detector HPGe impurity concentration less than 0 6 atoms/m 3 Marcel MiGLiERiNi MMiiii 7 Marcel MiGLiERiNi MMiiii 8 Standard Cryostat Configuration NaI(Tl) Gamma Spectroscopy We can use energy of detected gamma radiation to determine radionuclides and their activities. 60 Co 37 Cs Some types of silicon and all types of germanium detectors must be operated at low temperatures. GeLi Marcel MiGLiERiNi MMiiii 9 Marcel MiGLiERiNi MMiiii 30 5

Thermoluminescence Detectors TLD personal dosimeter Personal Dosimeters thermoluminescence -some materials, such as LiF and CaF, when exposed to radiation can store energy which can be released by heating to a certain temperature in a form of visible light scintillation is prompt luminescence thermoluminescence is delayed luminescence initiated by heating neutron personal TLD dosimeter 6 Li, 7 Li: beta + gamma 6 Li: neutrons 6 Li(n, α) 3 H Marcel MiGLiERiNi MMiiii 3 Marcel MiGLiERiNi MMiiii 3 Photographic Dosimeter Film Badge Dosimeters blackening evaluation It is well known that the effect of ionizing radiation on photographic emulsion is similar to that of visible light. The degree of blackening is a measure of the dose. Historical Hanford film badge dosimeter (970) Marcel MiGLiERiNi MMiiii 33 Marcel MiGLiERiNi MMiiii 34 Electronic Personal Dosimeter Energy Spectrum energy compensated silicon pin diode detector dose equivalent: µsv 0 Sv dose equivalent rate: µsv/h Sv/h alarm thresholds: current dose and dose rate day dose month/quarter cumulative doses interface bidirectional infrared RS-3 link pulses from a detector energy spectrum Marcel MiGLiERiNi MMiiii 35 Marcel MiGLiERiNi MMiiii 36 6

Signal Chain Signal Chain (cont.) detector preamplifier amplifier discriminator counter detector identification of ionizing radiation electronic output signal preamplifier amplification of a weak signal from detector (mv) impedance matching amplifier linear amplification to 0 V signal shaping (pile-up) optimization of signal-to-noise ratio timer discriminator analog-to-digital converter single-channel analyzer (SCA) sorts incoming signals according to their height LLD, ULD window modes of operation normal (or differential) window: ULD = LLD + E integral counter accumulation of pulses from SCA multichannel analyzer (MCA) different memory locations for different amplitudes of pulses Marcel MiGLiERiNi MMiiii 37 Marcel MiGLiERiNi MMiiii 38 7