ATEX/IECEx RTD temperature probe

Similar documents
Mineral-insulated thermocouples to DIN and EN

ED 701 General Industry Pressure Transmitter

Pressure Transmitter ED 701

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets

Installation Equipment

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Temperature Measurement

Single point load cells

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Exchangeable measuring insets SensyTemp TSA101

Certificate No.: IECEx BVS issue No. 1 Annex Page 1 of 8 Subject and Type

Z7A. Load cells. Special features. Data sheet. Wiring code

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Pressure transmitters for industrial applications MBS 32 and MBS 33

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Certificate No.: IECEx BVS , issue 3 Annex Page 1 of 9

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

ct m ive p 5/EC Thermal cut-outs

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Pressure Measurement Single-range transmitters for general applications

Thermometers. Applications

Industrial Resistance Thermometers according to DIN Model MWD

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Surface-mounting Thermostats ATH Type Series

EX-EMERGENCY LIGHT FITTINGS

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

8 Installation Equipment

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

Surface-mounting thermostats Series ATH

Field IT 50T Series Transmitters

Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230. KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 KTY 16-6

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

Conductivity sensor for hygienic applications

Temperature sensors SensyTemp TSP311, TSP321, TSP331

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

Ex floating switches and Ex immersion probes

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

ANNEX to IECEx Certificate

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Ring-Torsion Load Cells RTB

CDS. high density spring connection

Solenoid valves 2/2-way direct-operated type EV210A

ZF Series Force Transducers

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

PN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings

Construction and application of resistance thermometers

CONTACT TEMPERATURE MEASUREMENT

PRODUCT CATALOGUE PREssURE switch

TABLE OF CONTENT. ATEX Certificate. Designation code. Circuit diagrams. Sensors. Sensors. Explosion-proof sensors from Pulsotronic

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

Direct-operated 2/2-way compact solenoid valves Type EV210A

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

Air velocity & IAQ measuring instruments

Surface-mounting double thermostat

Installation guide 862 MIT / MIR

Size A DIN EN

Field mounted Temperature Transmitter TF212/TF212-Ex

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

SEN TRONIC AG 1 A 6 6 / "

Air velocity & IAQ measuring instruments

Type UB1 Load Cell. Option Stainless steel cable gland

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

Switches in conformity with ATEX directive

Capacitive Sensors. Contents

Industrial Pressure Transmitter

Thermal-Magnetic Circuit Breaker 2210-S2..

ISEmax CAS40D. Technical Information

Direct-operated 2/2-way solenoid valves Type EV210B

Linear Motors with ATEX and IECEx Certification

fischer connectors General Catalogue Edition 5.2

Thermal-Magnetic Circuit Breaker 2210-S2..

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

GB-distribution boxes and enclosures

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

SmartLine Radar Level Meter RM70

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

Designed to go where you work

Thermal-Magnetic Circuit Breaker 2210-S2..

Load Washers. Force kn until kn. Type 9101A A

Industrial Pressure Transmitter

I Ex d/e Switch- and Control-Equipment I

Pressure. 1 Fitting PA R - N R2

Pushbutton Units and Indicator Lights

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

ISEmax CAM40/CAS40. Technical Information

VA Master FAM540 Metal Cone Variable Area Flowmeter

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Physikalisch-Technische Bundesanstalt

Transcription:

Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or four-wire circuit Shielded connecting cables (silicone, PTFE, metal braiding/glass fiber, PVC, PUR, FEP, RADOX, BETAflam ) Application-specific design types Brief description Due to their specific features, ATEX/IECEx RTD temperature probes with connecting cables are used in pharmaceutical and chemical plants, power plants, pipelines, on test rigs, in engine manufacturing, and at any measuring locations requiring flexibility and simple replacement. The good thermal transfer between the protection tube and temperature sensor enables short response times and excellent measuring accuracy. The special construction guarantees a long operating life. A Pt100 temperature sensor according to DIN EN 60751, class AA, A or B in a two-wire, threewire or four-wire circuit is used as a measuring insert as standard versions with Pt500, Pt1000, Ni1000, or NTC are also possible. Basic type 902821/80 Ex i and 902821/90 Ex e Basic type 902821/81 Ex i and 902821/91 Ex e Basic type 902821/82 Ex i and 902821/92 Ex e Approvals/approval marks (see "Technical data")

Page 2/8 Technical data Connection Connecting cable ends stripped bare or with the insulation stripped in part, available with ferrules (standard), with plug-in sleeves, or multi-pole plug connectors Connecting cable Silicone Ambient temperature -50 to +180 C PTFE Ambient temperature -190 to +260 C Metal braiding/ glass fiber Ambient temperature -50 to +350 C PUR Ambient temperature -30 to +105 C PVC Ambient temperature -5 to +80 C or -5 to +105 C FEP Ambient temperature -5 to +105 C RADOX Ambient temperature -40 to +120 C BETAflam Ambient temperature -40 to +120 C FPM Ambient temperature -50 to +180 C PEEK Ambient temperature -60 to +180 C Protection tube Stainless steel AISI 316, Ø 3 mm, Ø 4 mm, Ø 5 mm, Ø 6 mm, Ø 7 mm, Ø 8 mm, and Ø 9 mm or in the case of the mineral-insulated RTD temperature probe: stainless steel 1.4541, Ø 1.9 mm, Ø 3 mm, and Ø 6 mm Protection tube constant As the diameter of the temperature probe varies, the protection tube constant varies as follows: 3.0 mm = 220 K/W 3.3 mm = 180 K/W 4.0 mm = 110 K/W 5.0 mm = 80 K/W The protection tube constant describes how the temperature rises on the surface of the probe as work is performed and must be taken into account when dimensioning the intrinsically safe electrical circuit and selecting the temperature class. Process connection Thread, clamping socket (clamp), or JUMO PEKA hygienic process connection Measuring insert Standard: Pt100 temperature sensor, DIN EN 60751, class AA, A or B available in two-wire, three-wire, or four-wire circuit NTC upon request

Page 3/8 Approvals/approval marks Approval mark Testing agency Certificates/ Inspection basis Certification numbers II 1/2 G Ex ia IIC T1... T6 Ga/Gb Electrosuisse SEV 13 ATEX 0197 EN 60079-0:2012 + A11:2013 II 1/2 G Ex ib IIC T1... T6 Ga/Gb EN 60079-11:2012 EN 60079-26:2007 II 1/2 D Ex ia IIIC T60 C... T80 C Da/Db IP6X II 1/2 D Ex ib IIIC T60 C... T80 C Da/Db IP6X II 2 G Ex ia IIC T1... T6 Gb Electrosuisse SEV 13 ATEX 0197 EN 60079-0:2012 + A11:2013 II 2 G Ex ib IIC T1... T6 Gb EN 60079-11:2012 EN 60079-26:2007 II 2 D Ex ia IIIC T60 C... T80 C Db IP6X II 2 D Ex ib IIIC T60 C... T80 C Db IP6X II 1/2 G Ex ia IIC T1... T6 Ga/Gb Electrosuisse IECEx SEV 13.0010 IEC 60079-0:2011 II 1/2 G Ex ib IIC T1... T6 Ga/Gb IEC 60079-11:2011 IEC 60079-26:2006 II 1/2 D Ex ia IIIC T60 C... T80 C Da/Db IP6X II 1/2 D Ex ib IIIC T60 C... T80 C Da/Db IP6X II 2 G Ex ia IIC T1... T6 Gb Electrosuisse IECEx SEV 13.0010 IEC 60079-0:2011 II 2 G Ex ib IIC T1... T6 Gb IEC 60079-11:2011 IEC 60079-26:2006 II 2 D Ex ia IIIC T60 C... T80 C Db IP6X II 2 D Ex ib IIIC T60 C... T80 C Db IP6X II 1/2 G Ex e IIC T1... T6 Ga/Gb Electrosuisse SEV 05 ATEX 0137 EN 60079-0:2009 II 1/2 D Ex tb IIIC T60 C... T80 C IP65 Da/Db EN 60079-7:2007 EN 60079-26:2007 EN 60079-31:2009 II 2 G Ex e IIC T1... T6 Gb Electrosuisse SEV 05 ATEX 0137 EN 60079-0:2009 II 2 D Ex tb IIIC T60 C... T80 C IP65 Db EN 60079-7:2007 EN 60079-26:2007 EN 60079-31:2009

Page 4/8 Dimensions rigid = 50 flexible EL 40 AL D Basic type 902821/80 Basic type 902821/81 Basic type 902821/82 Basic type 902821/90 Basic type 902821/91 Basic type 902821/92

Page 5/8 Order details (1) Basic type 902821/80 Ex i Screw-in RTD temperature probe 902821/81 Ex i Push-in RTD temperature probes 902821/82 Ex i Mineral-insulated RTD temperature probes (operating temperature in area of the sheath cable: -50to+600 C) D EL 40 AL (2) Operating temperature in C (connecting cable) x x x 317-60 to +180 C (PEEK) x x x 373-50 to +180 C (FPM) x x x 378-50 to +180 C (silicone) x x x 386-50 to +260 C (PTFE) x x x 402-50 to +400 C (metal braiding/glass fiber) x x x 478-40 to +120 C (RADOX ) x x x 484-40 to +120 C (BETAflam ) x x x 724-5 to +80 C (PVC) x x x 730-5 to +105 C (PVC) x x x 908 5 to 105 C (PUR) x x x 912 5 to 105 C (FEP) (3) Measuring insert x x x 1001 1 Pt100 in three-wire circuit x x x 1003 1 Pt100 in two-wire circuit x x x 1005 1 Pt1000 in two-wire circuit x x x 1011 1 Pt100 in four-wire circuit x x x 2001 2 Pt100 in three-wire circuit (protection tube diameter as of 6 mm with basic type 902821/82) x x x 2003 2 Pt100 in two-wire circuit x x x 2005 2 Pt1000 in two-wire circuit x x 2011 2 Pt100 in four-wire circuit x x 3028 3 Pt100 in 2 three-wire and 1 two-wire circuit (4) Tolerance class according to DIN EN 60751 x x x 1 Class B x x x 2 Class A x x x 3 Class AA (5) Protection tube diameter D in mm x 1.9 Ø 1.9 mm (sheath cable Ø 1.5 mm) x x x 3 Ø 3 mm x x 4 Ø 4 mm x x 5 Ø 5 mm x x x 6 Ø 6 mm x x 7 Ø 7 mm x x 8 Ø 8 mm x x 9 Ø 9 mm (6) Insertion length EL in mm (20 to 50000 mm)

Page 6/8 x x x... Specification in plain text (7) Process connection x x 000 None x 102 Screw connection G 1/4 x 104 Screw connection G 1/2 x 106 Screw connection G 1 x 114 Screw connection M10 1 x 115 Screw connection M10 1.5 x 121 Screw connection M14 1.5 x 163 Union nut G 3/8 x 164 Union nut G 1/2 x 165 Union nut G 3/4 x 254 Compression fitting G 1/2 x 611 Clamping socket (clamp) DN 10/20 DIN 32676 (AISI 316 L) x 613 Clamping socket (clamp) DN 25/40 (1 /1.5 ) DIN 32676 (AISI 316 L) x 616 Clamping socket (clamp) DN 50 (2 ) DIN 32676 (AISI 316 L) x 617 Clamping socket (clamp) 2.5 similar to DIN 32676 (AISI 316 L) x 997 JUMO PEKA hygienic process connection (AISI 316 L) (suitable process connection adapters, data sheet 409711) (8) Process connection material x x x 00 None x x 24 CrNi 1.4404 (AISI 316 L) x x 26 CrNi 1.4571 (AISI 316 Ti) x x 31 CrNi 1.4435 (AISI 316 L) x x 46 CuZn (brass) (9) Connecting cable end x x x 03 Bare connection wires x x x 05 Part stripping of the insulation x x x 11 Ferrules (standard) x x x 13 Plug-in sleeve 6.3 x x x 23 Tab connector 6.3 x x x 42 Lemosa coupling x x x 56 Machine connector M12 1 x x x 57 Machine connector M8 1 (10) Connecting cable length AL in mm (20 to 100000 mm) x x x... Specification in plain text (11) Extra codes x x x 000 None x x x 058 SIL- and PL-compatible x x 310 Protection tube stepped down from Ø 6 mm to Ø 4 mm x x 315 Strain-relief spring x x 316 Strain-relief hose x x x 317 Shielded connecting cable (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) Order code - - - - - - - - - /,... a Order example 902821/80-317 - 1001-1 - 3-200 - 104-26 - 11-2500 / 315 a List extra codes in sequence, separated by commas.

Page 7/8 (1) Basic type 902821/90 Ex e Screw-in RTD temperature probe 902821/91 Ex e Push-in RTD temperature probes 902821/92 Ex e Mineral-insulated RTD temperature probes (operating temperature in area of the sheath cable: -50to+600 C) D EL 40 AL (2) Operating temperature in C (connecting cable) x x x 317-60 to +180 C (PEEK) x x x 373-50 to +180 C (FPM) x x x 378-50 to +180 C (silicone) x x x 386-50 to +260 C (PTFE) x x x 402-50 to +400 C (metal braiding/glass fiber) x x x 478-40 to +120 C (RADOX ) x x x 484-40 to +120 C (BETAflam ) x x x 724-5 to +80 C (PVC) x x x 730-5 to +105 C (PVC) x x x 908 5 to 105 C (PUR) x x x 912 5 to 105 C (FEP) (3) Measuring insert x x x 1001 1 Pt100 in three-wire circuit x x x 1003 1 Pt100 in two-wire circuit x x x 1005 1 Pt1000 in two-wire circuit x x x 1011 1 Pt100 in four-wire circuit x x x 2001 2 Pt100 in three-wire circuit (protection tube diameter as of 6 mm with basic type 902821/92) x x x 2003 2 Pt100 in two-wire circuit x x x 2005 2 Pt1000 in two-wire circuit x x 2011 2 Pt100 in four-wire circuit x x 3028 3 Pt100 in 2 three-wire and 1 two-wire circuit (4) Tolerance class according to DIN EN 60751 x x x 1 Class B x x x 2 Class A x x x 3 Class AA (5) Protection tube diameter D in mm x 1.9 Ø 1.9 mm (sheath cable Ø 1.5 mm) x x x 3 Ø 3 mm x x 4 Ø 4 mm x x 5 Ø 5 mm x x x 6 Ø 6 mm x x 7 Ø 7 mm x x 8 Ø 8 mm x x 9 Ø 9 mm (6) Insertion length EL in mm (20 to 50000 mm) x x x... Specification in plain text (7) Process connection

Page 8/8 x x 000 None x 102 Screw connection G 1/4 x 104 Screw connection G 1/2 x 106 Screw connection G 1 x 114 Screw connection M10 1 x 115 Screw connection M10 1.5 x 121 Screw connection M14 1.5 x 163 Union nut G 3/8 x 164 Union nut G 1/2 x 165 Union nut G 3/4 x 254 Compression fitting G 1/2 x 611 Clamping socket (clamp) DN 10/20 DIN 32676 (AISI 316 L) x 613 Clamping socket (clamp) DN 25/40 (1 /1.5 ) DIN 32676 (AISI 316 L) x 616 Clamping socket (clamp) DN 50 (2 ) DIN 32676 (AISI 316 L) x 617 Clamping socket (clamp) 2.5 similar to DIN 32676 (AISI 316 L) x 997 JUMO PEKA hygienic process connection (AISI 316 L) (suitable process connection adapters, data sheet 409711) (8) Process connection material x x x 00 None x x 24 CrNi 1.4404 (AISI 316 L) x x 26 CrNi 1.4571 (AISI 316 Ti) x x 31 CrNi 1.4435 (AISI 316 L) x x 46 CuZn (brass) (9) Connecting cable end x x x 03 Bare connection wires x x x 05 Part stripping of the insulation x x x 11 Ferrules (standard) x x x 13 Plug-in sleeve 6.3 x x x 23 Tab connector 6.3 x x x 42 Lemosa coupling x x x 56 Machine connector M12 1 x x x 57 Machine connector M8 1 (10) Connecting cable length AL in mm (20 to 100000 mm) x x x... Specification in plain text (11) Extra codes x x x 000 None x x x 058 SIL- and PL-compatible x x 310 Protection tube stepped down from Ø 6 mm to Ø 4 mm x x 315 Strain-relief spring x x 316 Strain-relief hose x x x 317 Shielded connecting cable (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) Order code - - - - - - - - - /,... a Order example 902821/90-317 - 1001-1 - 3-200 - 104-26 - 11-2500 / 315 a List extra codes in sequence, separated by commas.