MARINE SEXTANT INTRODUCTION

Similar documents
Chapter 2. Altitude Measurement

Chapter 2: Measure of the Sun s Altitude: Ho

CHAPTER 16 INSTRUMENTS FOR CELESTIAL NAVIGATION

Modern Navigation. Thomas Herring

CHAPTER 16 INSTRUMENTS FOR CELESTIAL NAVIGATION

NEW STANDARD SEXTANT OF THE U. S. NAVY

Workforms. contents. Note on copyright and reproduction

CHAPTER 14 INSTRUMENTS FOR CELESTIAL NAVIGATION

Ph 3455/MSE 3255 Experiment 2: Atomic Spectra

Navigating by the Stars and Planets

Altitude NAVIGATION. Visible Horizon

Geometry of Earth Sun System

Complete Sun Sight Reduction Procedure

Modern Navigation. Thomas Herring

DUMMIES guide to Astro-Navigation

Guide to Polar Alignment of a Meade LX200GPS Telescope

QUADRANT WITH SPHERICAL LEVEL FOR FIXING THE POSITION IN A BALLOON.

Experiment #4: Optical Spectrometer and the Prism Deviation

DISPERSION OF A GLASS PRISM

This unit is primarily aimed at learners who intend to seek employment within the maritime industry.

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

CHAPTER 20 SIGHT REDUCTION

National Maritime Center

GERMAN TYPE EQUATORIAL MOUNT (FM 51/52 - FM 100/102 - FM150) USER MANUAL

Meridian Circle through Zenith, North Celestial Pole, Zenith Direction Straight Up from Observer. South Celestial Pole

Directions for use

Collimation with a Takahashi collimating scope

TELESCOPE POINTING ERRORS AND CORRECTIONS

Surveying Prof. Bharat Lohani Indian Institute of Technology, Kanpur. Module 5 Lecture 1

6-3 Solving Systems by Elimination

Instruction Manual. Model #: (Reflector) Lit #: / 06-07

THE DIFFRACTION GRATING SPECTROMETER

To determine the wavelengths of light emitted by a mercury vapour lamp by using a diffraction grating.

CIV : THEODOLITE ADJUSTMENT

SUN SIGHT REDUCTION CALCULATIONS

b. Assuming that the sundial is set up correctly, explain this observation.

Experiment #5: Cauchy s Formula

Laboratory Exercise 7 MEASUREMENTS IN ASTRONOMY

WATTS MICROPTIC ALIDADE OPERATING INSTRUCTIONS 20-7

NORTHERN ILLINOIS UNIVERSITY PHYSICS DEPARTMENT. Physics 211 E&M and Quantum Physics Spring Lab #9: Diffraction Spectroscopy

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

2 - Machining Fundamentals Measurement. Manufacturing Processes - 2, IE-352 Ahmed M El-Sherbeeny, PhD Spring-2015

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 FRAUNHOFER DIFFRACTION

Celestial Navigation. 6. Time Objective Greenwich Mean Time

C A S S I N I. MODEL : C EQ3 900mm X 135mm COSMO BRANDS INC.

D.A.R.V. (DSLR / CCD Drift Alignment by Robert Vice)

Galileo Telescope Solar Viewer Joseph Hora, Elizabeth Hora 2017/09/18

Surveying Prof. Bharat Lohani Indian Institute of Technology, Kanpur. Module - 5 Lecture - 3 Theodolites and Total Stations

Using Your Astrolabe

CHAPTER 11 USE OF SEXTANT IN PILOTING

Laboratory #29: Spectrometer

Marine Sextants: History & Technology

INTRODUCTION TO THE TELESCOPE

CHAPTER 19 SIGHT REDUCTION

7-6 Adding and Subtracting Polynomials

Energy Efficiency, Acoustics & Daylighting in building Prof. B. Bhattacharjee Department of Civil Engineering Indian Institute of Technology, Delhi

Seminar report Autocollimator Submitted in partial fulfillment of the requirement for the award of degree Of Mechanical

Data for Best Viewing of the Planets July 15, 2018

Interferometers. PART 1: Michelson Interferometer The Michelson interferometer is one of the most useful of all optical instru

Chapter 4. Dispersion of Glass. 4.1 Introduction. 4.2 Apparatus

Earth & Space Science, Interpreting Data DURATION Preparation: 5 minutes Activity: 40 minutes (total over one day)

Chapter Seven. Solar Energy

Design Considerations for a Variable Angle Absolute Reflectance Accessory For the LAMBDA 950/850/650 UV/Vis/NIR and UV/Vis Spectrophotometers

1 YEAR LIMITED WARRANTY TELESCOPES

How to Collimate a Newtonian Telescope

EXPLANATION OF NAVIGATION TABLES

INTRODUCTION FOREWORD

LAB 2: Earth Sun Relations

Operating Instructions Spectro-Goniometer Student. 1 Functional Elements. 2 Safety Precautions. Figure 1: Spectro-Goniometer Student

Answers to Lyra Celestial Navigation Refresher Exercise

Astro Navigation (i.e. Celestial Navigation)

Computer Activity #3 SUNRISE AND SUNSET: THE SEASONS

Lecture 2. September 13, 2018 Coordinates, Telescopes and Observing

Unit III Introduction sine bar Sine bar Working principle of sine bar

Introduction to Telescopes Pre-lab

Auto collimator. Introduction. Objectives: Apparatus: Theory:

Dispersion and resolving power of the prism and grating spectroscope (Item No.: P )

Experiment O-2. The Michelson Interferometer

THE UNITED REPUBLIC OF TANZANIA NATIONAL EXAMINATIONS COUNCIL CERTIFICATE OF SECONDARY EDUCATION EXAMINATION. Instructions

Lecture 8. October 25, 2017 Lab 5

ASTRONOMICAL NAVIGATION

EXPERIMENT 12 THE GRATING SPECTROMETER AND ATOMIC SPECTRA

Determination of Cauchy s Contants

CHAPTER 26 EMERGENCY NAVIGATION

AGES INSTRUCTION MANUAL. Juno 50mm Telescope Space Exploration Gear

MAHATMA GANDHI MISSION S JAWAHARLAL NEHRU ENGINEERING COLLEGE, AURANGABAD. (M.S.)

Quick Start Guide. The ieq45 GoTo German Equatorial Mount # 8000C

CHAPTER II THE COORDINATES SYSTEM AND FORMULARIES

Atomic emission spectra experiment

Appendix 2: Disassembling and Assembling the Telescopes and the Celestron Equatorial Mounts

UNIT-4 THEODOLITE SURVEYING

b. So at 12:00 p.m., are the shadows pointing in the direction you predicted? If they are not, you must explain this observation.

DISPERSION AND SPECTRA CHAPTER 20

Surveying Instruments. B Series B20 B30 B40. Automatic Levels


LESSON PLAN - Optimum Orientation of Solar Panels Using Soltrex Data

3. a. In the figure below, indicate the direction of the Sun with an arrow.

NAVIGATION THEORY QUESTIONS Basics of Navigation

Telescope. 1. Read these instructions carefully and familiarise yourself with the procedure before assembling the unit.

Dispersion of Glass Introduction Apparatus Theory

Transcription:

MARINE SEXTANT INTRODUCTION The marine sextant is used by the mariner to observe the altitude of celestial bodies as well as to measure horizontal and vertical angles of terrestrial objects. On the image of a sextant below I have highlighted the main component features: Shades Index Mirror Telescope Horizon Mirror Arc Clamp Frame Micrometer Index Arm PRINCIPLE OF USE The principle of the sextant is based on the first law of light. That being that when a ray of light is reflected from a plane mirror the angle of incidence of the ray equals the angle of reflection. For a sextant the light is reflected twice in the same plane from the index mirror to the horizon mirror then again from the horizon mirror to the telescope.

In these circumstances the angle between the first and last direction of the ray of light is twice the angle between the index and horizon mirrors. ERRORS The sextant suffers from two main types of error, correctable and non-correctable. The latter as the name suggests may only be rectified by returning the device to the manufacturer for servicing. Correctable Errors There are three different correctable errors which the OOW can easily rectify providing they have the knowledge to do so. These errors should be adjusted for in a particular order as follows: First Adjustment Error of Perpendicularity This is caused by the index mirror not being perpendicular to the plane of the instrument. To check whether this error is present the OOW should set the index arm about half way along the arc. The sextant should be held horizontally and the OOW should look obliquely into the index mirror. The true and reflected arcs should be aligned with one another. If this is not the case then error of perpendicularity exists. This error can be resolved by adjusting the screw at the rear of the index mirror until the true and the reflected arcs are aligned. Second Adjustment Side Error This occurs when the horizon mirror is not perpendicular to the plane of the instrument. There is two simple ways for the OOW to check whether this error is present. The easiest in my opinion is to observe a star. The sextant should be held vertically and the index arm set to 0. A bright star with a low magnitude should be observed through the telescope if the true and reflected images are shown side by side then side error is present. During daylight hours it is also possible to test for side error by setting the index arm to 0 and holding the sextant at a small angle off horizontal. You should look through the telescope and observe whether the reflected and true horizons are misaligned. In this instance it will appear that one is slightly higher or lower than the other. If this misalignment is present then once again it can be said that side error is present. In either instance to correct for this error you should adjust the screw located on the index mirror furthest from the plane of the instrument. An easy way to remember which screw if you re unsure is side error, side screw. You should continue to make the adjustment to the screw until the image is aligned.

Third Adjustment Index Error This occurs when the horizon and index mirrors are not parallel to each other when the index arm is set at 0. There is three main methods to detect whether index error is present. Observation of a star Set the index arm to 0 and observe a star of a low magnitude. If the reflected star is observed higher or lower than the true star then index error must exist. Observation of the horizon Set the index arm to 0 and hold the sextant vertically. If the true and reflected horizons are not aligned then index error exists. In both these methods the value of the index error can be obtained by adjusting the micrometer until the true and reflected images are aligned. The OOW can then simply observe the micrometer reading importantly noting whether the error is on or off the arc. The final method of checking for index error is slightly more convoluted. It involves taking observations of the sun. Firstly set the index arm to approximately 32 on or off the arc and then using the micrometer raise or lower the sun so that the true and reflected images of the suns lower and upper limbs are in contact with one another, then repeated with the limbs in the opposite position, as illustrated below: True Reflected Reflected True On each observation you should note the reading on the micrometer e.g. 32 on the arc and 29 off the arc. The index error is then easily calculated by subtracting the lesser observation from the greater observation and dividing the result by two. The value of on or off the arc is dictated by the greater of the two observations. The example above would be calculated as follows: Index Error= 32-29 = 1.5 on the arc. 2

If you are in doubt as to the accuracy of this methodology it can be verified by adding the two observations together and dividing them by 4. The result should be equal to the suns semi-diameter as tabulated in the nautical almanac for the date of the observation. Index error can be solved using two different methods. If the error is very small for example only 1 or 2 then the mariner can simply note the value of the error and include this in their subsequent calculations. For larger errors however this error can be corrected by adjusting the screw on the horizon mirror which is closest to the plane of the instrument, making small alterations until the images are aligned. Non Adjustable Errors: The sextant has the potential to suffer from the following non-adjustable errors which can only be solved by returning the instrument to the manufacturer for servicing/repair. 1. Centering Error Occurs when the index arm does not pivot along the exact point at the centre of the arcs curvature. This is normally caused by a worm pivot which the index arm moves on. 2. Prismatic Error Caused when the faces of the two mirrors are not parallel to each other. 3. Shade Error Caused by the faces of the shades not being parallel to each other. Should this error exist it is possible to use the telescope with a dark eyepiece rather than sending the whole device away for servicing. 4. Graduation Error This error is caused by imperfections on the arc or the scales of the micrometer/vernier. 5. Worm and Rack Error Occurs by failures in the worm and rack gearing of the micrometer and main arc. 6. Collimation Error Occurs when the telescope is not parallel to the plane of the instrument. Instrument Error The sextants manufacturer calculates all of the nonadjustable errors at the time of production or servicing and issues each sextant with a certificate in its case. These errors are combined into a single instrument error which is given as on or off the arc.

HOW TO READ A SEXTANT 42 0.5 29 As well as being able to correct the instrument the OOW must understand how to read it. There is three steps in this process. Firstly you must note the number of full degrees indicated in the arrow on the index arm pointing to a corresponding value on the sextant arc in this example 29. Secondly you should note the number of full minutes which can be obtained by reading the nearest value on the micrometer drum which is beside the 0 graduation on the Vernier scale. Here is reads 42. Finally the fraction of a minute is obtained by examining the Vernier scale. The mark which most matches a mark on the micrometer drum indicates the value. In this instance 0.5. By observing the image above you can state that the reading for this sextant is 29 42.5 on the arc.

CONCLUSION Despite the advancements of modern technology the sextant remain an essential tool for obtaining celestial observations. It remains important that every deck officer is aware of how to use, correct and read a sextant.