Digital Torque Meter ADT-C Series OPERATION MANUAL

Similar documents
Acceleration/Velocity/Displacement VIBRATION METER

Bright Advance Corporation

AW/AHW Professional Weighing Scale. User Manual

OP-02 / OP-03 / OP-04

GW Professional Weighing Scale. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW

Agilent 4263B LCR Meter Operation Manual. Manual Change. Change 1 Add TAR in Test Signal Frequency Accuracy Test (Page 9-38) as follows.

244241, Operation Manual Contents subject to change without notice. Version 1.0 Issue AA

MP3 Digital Voice Module Model No.: VCM-SD Rev.A3. Content

ED 701 General Industry Pressure Transmitter

Dual laser + type K thermometer INFRARED THERMOMETER

Minimum (-31) every 10 s -35 (-31)

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System

Pressure Transmitter ED 701

DIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

RQ1A070AP. V DSS -12V R DS(on) (Max.) 14mW I D -7A P D 1.5W. Pch -12V -7A Power MOSFET. Datasheet 外観図 内部回路図 特長 1) 低オン抵抗 2) ゲート保護ダイオード内蔵

DIGITAL THERMOMETER OPERATOR S MANUAL

Dewpoint Meter Data Sheet / Instructions

Single cam type. Double cam type. Grip force N. Type Model/size Stroke Screw type straight style. Screw type tee style

Data Sheet / Instructions. Dewpoint MeterO

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Operation Manual Contents subject to change without notice

PG-200/PG-208 PRESSURE GAUGES P G G P P

Product Specification

473 Dew Point Hygrometer

VIBRATION METER. Instruction Manual.

STANDARD OPERATING PROCEDURE


SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

Vet Photometer DP 700 Operating Manual. Version V5.9

FATEK. FBs-1HLC. Precision Load Cell Module. Operation manual V1.1 06/07/2017 FATEK AUTOMATION CORP.

Nichia STS-DA <Cat.No > SPECIFICATIONS FOR NICHIA LUMINOUS FLUX WHITE STANDARD LED MODEL : NLHW01S02 NICHIA CORPORATION

473-SHX Dew Point Mirror

Operating Instructions for Digital Manometer. Model: MAN-SD

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

OPERATING INSTRUCTIONS

O P E R A T I N G M A N U A L

PG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive

PS R975B 12R976B 12R977B 12R978B 12R979B

WEIGHT INDICATOR WIDRA W90

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Circular Motion and Centripetal Force

Automatic titrators, TitroMatic

英語問題 (60 分 ) 受験についての注意 3. 時計に組み込まれたアラーム機能 計算機能 辞書機能などを使用してはならない 4. 試験開始前に 監督から指示があったら 解答用紙の受験番号欄の番号が自身の受験番号かどうかを確認し 氏名を記入すること

ランプブラケット モールドタイプランプブラケット品番説明

Quick Start Guide. The ieq45 GoTo German Equatorial Mount # 8000C

473 Dew Point Hygrometer

Instruction Manual HI Refractometer for Invert Sugar Measurements

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

MAN-SGY-012-V11 EC 5195 Fairford Electronics Ltd - Synergy Modbus RTU Programming Manual - 22nd February 2016 Page 1 of 59.

Sitting height... 6 Back tilt and back height... 6 Armrest... 7 Brakes... 7 Charging VELA Tango 300E... 7

SAFETY STANDARD APPROVED METALLIZED POLYPROPYLENE CAPACITOR 海外規格メタライズドポリプロピレンコンデンサ TYPE ECQUA

1WMPD GXA-25 External fanless ionizer

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

UNIVERSAL SIGNAL INTERFACE UNIT

ea980r Digital Anemometer User Manual

京都 ATLAS meeting 田代. Friday, June 28, 13

INFRARED THERMOMETER Model : TM-959

Mini Environmental Quality Meter

ONOSOKKI HT Handheld Tachometer. Instruction Manual ONO SOKKI CO., LTD.

Portable ph/orp/ion Meter D-73 Instruction Manual CODE:GZ A

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

CTC 155 / 350 / 660 Dry-block calibrator

C A S S I N I. MODEL : C EQ3 900mm X 135mm COSMO BRANDS INC.

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

INE-PHS-3E ph Meter Operating Manual

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

PAR Meter Instruction Manual. Product # Product # Year Warranty

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

INSTRUCTION MANUAL RS 51 & RS 52 DIGITAL THERMOMETER

Bante210 Benchtop ph Meter Instruction Manual

INE-DDB-303A Portable Conductivity Meter Instruction Manual

User's Guide. DISTO online. Leica Geosystems

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

MODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

IDENTIFICATION STS400

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

HD32.2 WBGT Index HD 32.2 INSTRUMENT FOR THE ANALYSIS OF THE WBGT INDEX

Title rays. Citation Advanced Materials Research, 409: 5. Issue Date Journal Article. Text version author.

Please complete this form and enclose it with your carefully packed watch for repair. Add a check for postage and handling.

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

Youhei Uchida 1, Kasumi Yasukawa 1, Norio Tenma 1, Yusaku Taguchi 1, Jittrakorn Suwanlert 2 and Somkid Buapeng 2

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

34000 Series. Compact High Power DC Electronic Load. Prodigit Electronics Co., Ltd. 60V 600V 1000V. 20 Models Type. 5kW~ 40kW. Features.

Thermal Mass Flow Meter for Gases

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

Red and Green Dot Sight FF26002 USER MANUAL

Transcription:

ADT-C Series Digital Torque Meter ADT-C Series OPERATION MANUAL CO., LTD

Digital Torque Meter It is the torque-measuring instrument of the electronic formula which can measure torque power. It corresponds to a large area from the field of a quality control to the research and development. Our Digital Torque Meters are used well to check intensity or movement of some parts in automobile industry, electric industry and etc. Features Our Digital Torque Meter has original design. Sampling Speed 1ms The digital range of display is max. 9999. Digimatic, Analog, RS-232C and Comparator out-put are attached as standard accessory. Example Use Peak Holding Measurement and Tracking Measurement Peak Holding Memory is 50 Measurements Value. The limit of HI(HIGH) and LO(LOW) can be made by comparator out-put. Selectable 3 units (N m Kg f cm in lbf) Battery Volume can be checked on display. Power auto-off function. When there is no key 5 minutes,a power supply is turned off automatically.. -1-

Notes Do not overload The limit of overload capacity is 120% of full scale. When the load is reached to 110% of Full Scale, OVER LOAD is indicated on display. Keep it within 100% of Full Scale. This is the cause forthe breakdown of load sensor. In case of over load setting 1~100 %, OVER LOAD will be indicated on display when the load is reached over your setting value. (Regarding over load setting, please see page No.9.) Do not use other adapter Should other adapter be used, there are possibility to breakdown or may lead to a fire. Also, do not charge or operate unit in other voltage. Do not impact or damage unit This is the cause for the breakdown of load sensor or other troubles. Do not store and operate in the following conditions Wet area Where dew condensation Dusty area Where oil or chemicals Do not disassemble, trouble-shoot and remodel Should you perform any of these, that may cause malfunction of the unit. -2-

Specifications Standard Specifications Measuring Unit : Selectable 3 units N m(n cm)/kgf cm/in lbf Accuracy : ±0.5% of F/S Measurement : Peak Holding / Tracking Peak Holding : Digital Peak Holding Peak Holding Memory : 50 Measurement Values Sampling Speed : 1ms Display : 4 digits LCD Over Load Capacity : 120% Auto Power Off Term : 5 minutes Attachment : Please refer page No.5 and 6. Net Weight : About 3.2 kg Guarantee : 1 year Power Supply : Rechargeable Ni-MH Battery (Charging Time : About 4 hours) Out-Put : 1Digimatic out-put 2RS-232C out-put 3 Reset signal in-put 4Comparator out-put 5 Analogue out-put (±1V) *Regarding the details for out-put, please refer page No.13. -3-

Model & Indication Range MODEL ADT-C1 ADT-C2 ADT-C5 ADT-C10 ADT-C20 ADT-C50 ADT-C100 ADT-C200 Measuring Range Min. Indication 1.000-9.999N cm/0.100-1.000kgf cm/0.100-1.000in lbf 0.001N cm/0.001kgf cm/0.001in lbf 2.00-20.00N cm/0.200-2.000kgf cm/0.200-2.000in lbf 0.01N cm/0.001kgf cm/0.001in lbf 5.00-50.00N cm/0.500-5.000kgf cm/0.500-5.000in lbf 0.01N cm/0.001kgf cm/ 0.001in lbf 0.100-0.999N m/1.000-9.999kgf cm/1.000-9.999in lbf 0.001N m/0.001kgf cm/0.001in lbf 0.200-2.000N m/2.00-20.00kgf cm/2.00-20.00in lbf 0.001N m/0.01kgf cm/0.01in lbf 0.500-5.000N m/5.00-50.00kgf cm/5.00-50.00in lbf 0.001N m/0.01kgf cm/0.01in lbf 1.000-9.999N m/10.00-99.99kgf cm/10.00-99.99in lbf 0.001N m/0.01kgf cm/0.01in lbf 2.00-20.00N m/20.0-200.0kgf cm/20.0-200.0in lbf 0.01N m/0.1kgf cm/0.1in lbf 1 In case of 100% to 110% of full scale of measuring range, the display indicate the measuring value. However this measuring value can not be used for your measurement. Incase of 110% over, OVER LOAD is indicated on display. (This is in case of over load setting 0 ) In case of over load setting 1 ~ 100 %, OVER LOAD will be indicated on display when the load is reached over yoursetting value. (Regarding over load setting, please see page No.9.) -4-

Standard Attachments for each model Model No. Standard Accessories (each 1 pce.) ADT-C1 TC-2 TSS-5 ADT-C2 TC-2 TSS-5 ADT-C5 TC-2 TSS-5 ADT-C10 TC-3 TSS-10 ADT-C20 TC-3 TSS-20 ADT-C50 TC-6 TSS-30 ADT-C100 TC-4 TSS-30 ADT-C200 TC-4 TSS-30 Attachments ADT-C1 2 5 TSS-5 TC-2 (M3Screw/#2+With Spring) (M3Screw/#2) 0.1~0.5N m TSS-5: Screw is areplacement formula. Screw of the side is loosened. *Reserve:Two screws each are attached. ADT-C10 TC-3 (M4Screw/#2) TSS-10 (M4Screw/#2+With Spring) 0.2~1N m TSS-10: Screw is a replacement formula. Screw of the side is loosened. *Reserve:Two screws each are attached. -5-

ADT-C20 TC-3 (M4Screw/#2) TSS-20 (M5Screw/#2+With Spring) 0.5~2N m TSS-20: Screw is a replacement formula. Screw of the side is loosened. *Reserve:Two screws each are attached. -5-2-

ADT-C50 TC-6 (M5Screw/#2) TSS-30 (M6Screw/#3+With Spring) 0.5~3N m TSS-30: Screw is a replacement formula. Screw of the side is loosened. *Reserve:Two screws each are attached. ADT-C100 200 TC-4 (M6Screw/#3) TSS-30 (M6Screw/#3+With Spring) 0.5~3N m TSS-30: Screw is a replacement formula. Screw of the side is loosened. *Reserve:Two screws each are attached. -6-

-7- L C D D i s p l a y M o d e l a n d M a x. C a p a c i t y S t i c k e r -7- F u n c t i o n S w i t c h D a t a O u t p u t S w i t c h P o w e r S w i t c h R e s e t S w i t c h P o w e r C o n n e c t o r E x t e r n a l I n p u t / O u t p u t G a i n A j u s t D i a l G A I N C O N. D C M A D E I N J A P A N A D T - C 2 0 M A X. C a p a c i t y 2. 0 0 0 N m 2 0. 0 0 K g f c m 2 0. 0 0 i n l b P D F R E S E T D I G I T A L T O R Q U E M E T E R 注意事項 表示の最大許容値以上を絶対に加えないで下さい 連続での衝撃測定には使用しないで下さい 充電時間は絶対に 4 時間以内にして下さい P r e c a u t i o n s L o a d m u s t n o t e x c e e d m a x c a p a c i t y. A v o i d s u c c e s s i v e s h o c k t e s t s. D o n o t r e c h a r g e f o r m o r e t h a n 4 h o u r s. M A D E I N J A P A N N O. 1 2 3 4 5 S e r i a l N u m b e r S t i c k e r P r o t e c t i o n G l a s s M e a s u r i n g S o c k e t Description of Parts Name

Explanation of each parts (1) EXTERNAL INPUT / OUTPUT (CON.) It is possible to do the various outside output and display reset from outside. For details, see the explanation of the output connector page No.9. POWER CONNECTOR (DC) Insertion connector of AC adapter for the charging. The standard recharging time is about 4 hours after making a power off. The charging condition can be confirmed by display when making a power on. Also, it can be used inserting AC adapter. However, it becomes the cause which hastens the degradation of the charging battery. Recommend to use without using AC adapter as much as possible. GAIN ADJUST DIAL ONLY MANUFACTURE SIDE (NEVER CHANGE THIS DIAL) It is used when the calibration at the manufacture. LCD DISPLAY Using graphic LCD (liquid crystal), it is possible to show a feature character, setting character, numbers and charging scale in the display. PROTECTION GLASS Digital display is covered by protection glass. MODEL AND MAX. CAPACITY STICKER Model number and maximum display value of 3 units and indicated. POWER SWITCH (P) On/Off button of the power. The buzzer sounds in case of start the operation. DATA OUTPUT SWITCH (D) Output button for the digimatic signal and RS-232C signal of the data. It outputs a digital signal firstly and it outputs a RS-232C signal. (Caution) It outputs the digital signal when using a functionfeature. Also, in case of function feature (FU), it can be changed Peak Hold and Tracking, the reading of memory data and various setting of value. -8-

Explanation of each part(2) UNCTION SWITCH (F) This button is for setting up each function. To change function mode, keep to push about 6 seconds. ( FU is indicated in LCD Dispay), can be set up each function. RESET SWITCH This button is for resetting data indication of peak-hold and tracking. Besides when the mode is function (FU), you can reset all of the memory data (but cannot reset the data one-by-one), and can alter the figure (then the figure is underlined) by this button. SERIAL NUMBER STICKER Serial number is mentioned on this sticker. MEASURING SOCKET Attachment should be set on this measuring socket. -9-

Explanation of a button setting function (1) Various functional set up in button operation. Set up the function 1 Change Peak Hold (PEAK) and Tracking (TRUCK) 2 Check Memory (MO) Data and Elimination of all memory data 3 Set up Comparator Function (HI) 4 Set up Comparator Function (LO) 5 Change Measuring Unit (UN) 6 Set up Over Load (OV) 7 Set up Power Auto Off(AP) 8 Set up Number of Digits on display / NP setting 9 Reverse Digital Display Power switch is turned ON while pressed the P-button. (Becomes MEASUREMENT MODE) (When there is no key 2-3minutes,a power supply is turned off automatically) Keep to push F button about 6 seconds, indicate by FU unction). (Becomes SETTING MODE) Preparations the various setting were completed. The programming procedure after FU display 1 Change Peak Hold (PEAK) and Tracking (TRUCK) Change the Peak hold (PEAK) and change the tracking (TRUCK) when pressed the D button. (Initial setting : TRACK) 2 Check Memory (MO) Data and Elimination of all memory data MO in the upper right side of the display.can be confirmed the memory date. The memory data is advanced when press the D button. (from M01 up to M50) Elimination of all memory data should press the RESET button. (Each data is not eliminable) The display indicate MO 0 when data is eliminated. (Initial setting : 0) 3 Set up Comparator Function (HI) Set up the upper limit of comparator function Figure rising by D-button and Digit rising by RESET-button. When not using this function, setting to the 0. (Initial setting : 0) -10-

Explanation of a button setting function (2) 4 Set up Comparator Function (LO) Set up the low limit of comparator function. Figure rising by D-button and Digit rising by RESET button. When not using this function, setting to the 0. (Initial setting : 0) 5 Change Measuring Unit (UN) To push D button, display change from N Kgf lb f N (Initial setting : N) 6 Set up Overload (OV) Count up by D button. Figure up by RESET button. Setting value is %. It cannot set under 0. When not using this function, setting to the 0. (Initial setting : 0) In case of setting 0, OVER LOAD will be indicated on display when the load is reached from 100% to 110% of full scale. 7 Set up Power Auto Off(AP) To push D button, Set up the Power auto off 1 release 0 (Initial setting : 1) 8 Set up Number of Digits on display / NP setting (NP) Push "D" button. If you need 3 digits on display, please set"1". If you need 4 digits, please set " 2 ". It is possible to change number of digits by this function. 9 Reverse Digital Display The Value becomes flashing & dark. To push D button, the direction of display indication is reversed in upside down position. TO 1 Change Peak Hold (PEAK) and Tracking (TRUCK) Keep to push F button about 6 seconds, the gauge is now ready to measure. -11-

Digital indication for function mode It will become FU display if F Switch is pushed for about 6 seconds. (Measurement functional stop state) Next,if F Switch is pushed, a setup of each function can be performed. PEAK FU N m PEAK FU MO 0 PEAK N m FU HI N m PEAK FU LO PEAK FU UN PEAK FU OV N m N m N m PEAK FU AP PEAK FU NP PEAK FU N m N m N m *Display reversed with D Switch PEAK FU N m Digital indication for warning messages Over Load Indication Low Battery Indication OVER LOAD BATT -12-

External Input / Output *Connector of HIROSE brand HR25-9TR-16S is used.(16 pins) Please prepare a plug HR25-9TP-16P. Name of signal for each connector pin is as follows. 1.Analog output ±1V 2.Analog GND 3.Signal input for External reset Indication reset 4.Input COM 5.Comparator HI Open Collector Output (50V / 100mA) 6.Comparator GO 7.Comparator LO 8. 9.Output COM 10.RS-232C Rx Please refer the following RS-232C Format 11.RS-232C Tx 12.Digimatic output (DATA) 13.Digimatic output (CK) 14.Digimatic output (RD) 15.Digimatic output (REQ) 16. GND Connector Form 1 3 4 8 9 13 14 16 RS-232C Format 1. Interfacing (Bit) Spec. Start Bit : 1 bit Date Length : 8 bit Stop Bit : 1 bit Parity : None Baud Rate : 9600 BPS -13-

CO., LTD. 600-5 HIGASHI TAKADACHO, TOYOHASHI AICHI 441-8115 JAPAN. TEL : (0532)-41-5357 FAX : (0532)-41-4826 URL:http://www.attonic.co.jp E-mail:info@attonic.co.jp