REVERSE ENGINEERING PHARMACEUTICAL FORMULATION USING THE MORPHOLOGI G3-ID.

Similar documents
Component specific particle characterisation of the active components in a pharmaceutical topical formulations

Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS)

Morphologically directed chemical identification Coupling particle characterization by morphological imaging with Raman spectroscopy

Sample measurements to demonstrate Zetasizer specifications (Zetasizer Nano, Zetasizer APS, Zetasizer μv)

Introducing the Morphologi G3 ID The future of particle characterization

The Diffusion Barrier Technique, Practical Aspects and Data interpretation

MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20

Measurements of protein electrophoretic mobility using the Zetasizer Nano ZSP

next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

Laser diffraction and automated imaging: complementary techniques for nasal spray development

Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

Nanobubble Applications and Characterization by Nanoparticle Tracking Analysis

GPC/SEC Analysis of Polymer Degradation

ZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight

Differentiation of polymer branching and composition using the Mark Houwink plot

Electrophoretic Light Scattering Overview

10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS

Overcoming and quantifying Wall Slip in measurements made on a rotational rheometer

Method validation for laser diffraction measurements

Use of DLS/Raman to study the thermal unfolding process of lysozyme

Evaluating the rheological properties of hyaluronic acid hydrogels for dermal filler applications

Using rheology to study the hardness and spreadability of butter

The ultimate in desktop particle characterization

The ultimate in desktop particle characterization

Determining cure profile and post-cure shrinkage of photopolymers using UV accessory on a rotational rheometer

Snowy Range Instruments

GPC/SEC Analysis of Polymer Solutions Used in Inkjet Printing

Studying the Effect of Steric Layer Thickness on Emulsion Stability

Inform is a series of white papers designed to provide advice on material characterization issues. Mie theory The rst 100 years

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

Understanding the colloidal stability of protein therapeutics using dynamic light scattering

Introduction to the calculators in the Zetasizer software

MORPHOLOGI 4 RANGE. Automated imaging for advanced particle characterization

Executive Summary. Introduction WHITEPAPER

Characterization of Single Wall Carbon Nanotubes (SWNTs) by combining Dynamic Light Scattering and Raman Spectroscopy

Measuring the flow properties of powders. FT4 Powder Rheometer. freemantechnology

The power of multi-detector SEC in the analysis of antibodies

How switching mobile phases can improve your OMNISEC results

How to use GPC/SEC for compositional analysis

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

SARA Pharm Solutions

QbD QUANTITATIVE MEASUREMENTS OF CQAS IN SOLID DOSAGE FORM UNIT OPERATIONS

Using the Zetasizer Nano to optimize formulation stability

ISO INTERNATIONAL STANDARD. Sample preparation Dispersing procedures for powders in liquids

MATERIAL SAFETY DATA SHEET

PARTICLE SIZE CHARACTERISATION OF AGRICULTURAL SPRAYS USING LASER DIFFRACTION

CONTINUOUS FLOW CHEMISTRY (PROCESSING) FOR INTERMEDIATES AND APIs

CDER Risk Assessment to Evaluate Potential Risks from the Use of Nanomaterials in Drug Products

Preformulation & Solid State Chemistry Services

SCI Career Options Seminar My Career in the Pharmaceutical Industry. Gareth Ensor, AstraZeneca University of York 14 th November 2012

ActiPix SDI300 Surface Dissolution Imaging System

Physicochemical Characterization of Acyclovir Topical Semisolid Dosage Forms Towards TCS Validation Flavian Ștefan Rădulescu, Dalia Simona Miron

KINEXUS DSR SERIES REDEFINING RHEOMETER CAPABILITIES FOR ASPHALT TESTING

MetWorks Metabolite Identification Software

Surface Zeta Potential Cell (ZEN1020)

Setting Attainable and Practical Particle Size Specifications

Levasil and Bindzil colloidal silica dispersions. for the adhesive industry uses and benefits

Pharmaceutics and Pharmaceutical Technology

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

WHITE PAPER ENSURING CONSISTENCY IN POLYMORPHIC DRUG SUBSTANCES AND PRODUCTS: When and How to Apply a Specification Limit

Guide to Registration Requirements for Active Substance Manufacturers, Importers and Distributors in Ireland

Retail Price List. 200 Plus Skilled Manpower 35+ Domestic Market w.e.f. 01/06/2015 This price list supersedes all previous price list(s).

Handling Human Interpreted Analytical Data. Workflows for Pharmaceutical R&D. Presented by Peter Russell

Introduction to E&Ls 1

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS

HIGH PERFORMANCE PARTICLE SIZER THE FIRST SYSTEM TO COMBINE HIGH SENSITIVITY WITH A HIGH CONCENTRATION CAPABILITY

Testing for particles in injectable products

ISO INTERNATIONAL STANDARD

Phone: +44 (0) or BioPortfolio Limited

Systems, services and solutions for material characterization

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Understanding the conformational stability of protein therapeutics using Raman spectroscopy

Ultrasonic Spectroscopy a rheological tool?

Elemental Scientific. Spike Recovery. Elemental Scientific

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

Accelerate Unknown Detection in Emerging Drug Testing Using Thermo Scientific Compound Discoverer and mzcloud

Bindzil for the beverage industry. Colloidal silica dispersions uses and benefits

Harmonisation of product notification. Ronald de Groot Dutch Poisons Information Center

Reference: 4880(DOP.ADA)1136 Subject: Survey on the integration of geographic information systems into postal address development

HCS CellMask Stains. Introduction

Solution Story: Dr. Carsten Schauerte, Managing Director of solid-chem GmbH

International Symposium Standardisation of non-targeted methods for food authentication, Session II: Standardisation of Analytical Methods

Since 1988 High Force Research has worked with organizations operating in practically all end use sectors requiring chemical synthesis input, and

Practical Pharmaceutical Technology I USP Dissolution Method for PARACETAMOL 500 mg Tablets Section No. 6 Group D

Bohlin. Rheological instruments backed with rheological experience. Rheological properties

INGREDIENT-SPECIFIC PARTICLE SIZING: REDUCING RISK, CUTTING COST AND SAVING TIME IN PRECLINICAL INHALABLE FORMULATION DEVELOPMENT

Particle Characterization of Pharmaceutical Products by Dynamic Image Analysis

SOUTH AFRICAN NATIONAL STANDARD

Measuring the rheology of thermoplastic polymer melts

Teaching Old Drugs New Tricks: Applications of ASAP in OTC Product Development. The Procter and Gamble Company SoS 9/26/16

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Application of Geographic Information Systems for Government School Sites Selection

Elemental Scientific. Spike Recovery. Elemental Scientific

CIMA Dates and Prices Online Classroom Live September August 2016

A Basic Guide to INFORM WHITE PAPER. Abstract:

Humidity Calibration Solutions

GIS FOR MAZOWSZE REGION - GENERAL OUTLINE

3.0 APPARATUS : Capsule Machine, Analytical balance, Spatula, Beaker, Pestle and mortar, Powder paper.

Particle Size and Shape Analysis in PHARMACEUTICAL INDUSTRY.

Powder. Aulton Chapter 8-10,14,24. Powders

Transcription:

REVERSE ENGINEERING PHARMACEUTICAL FORMULATION USING THE MORPHOLOGI G3-ID. Introduction According to the definition established by the FDA, a generic drug is a drug product which is comparable to a reference listed drug (RLD) product in dosage form, strength, route of administration, quality, performance characteristics, and intended use. Rigorous rules and regulations pertaining to abbreviated new drug application (ANDA) submissions are complex and the generic drug industry strives to meet these regulations to obtain FDA s approval. And being the first to file is the most fundamental principle in the generics business because several companies compete to create generics of successful products going off patent. Therefore, generics companies must be highly skilled and disciplined in product development and achieving bioequivalence the most critical development area. Though generics companies commonly use reverse engineering techniques, the topic and, more importantly, the tools needed to carry out the process are rarely discussed in the public domain. In this application note we discuss one such tool that can be used for oral solid dose formulations. Case Study Two cold remedy formulations were analysed on the Morphologi G3-ID: one was a commercial brand and the other a generic one. Individual components within the formulations were identified by comparing their Raman spectra with those in a commercial database. Once the components were identified the particle size distributions of individual components in each formulation were compared, as was the overall composition of the two formulations. Methodology The cold remedies were dry powder formulations that were automatically dispersed and analysed using the Morphologi G3-ID. 13 mm3 of sample was dispersed using the instrument s integrated dry powder dispersion unit using the low pressure dispersion option. Figure 1 shows an example image of one of the dispersed samples. The samples were morphologically analysed using the 5 x objective. Particles with a circular equivalent diameter (CED) larger than 25 μm were targeted for the Raman chemical identification. In this case the acquisition time was 10 seconds for each particle and spectra from a few thousand particles from each sample were gathered in an overnight analysis. Malvern Instruments Worldwide Sales and services centres in over 65 countries www.malvern.com/contact 2013 Malvern Instruments Limited MRK1937-01 1

Figure 1: Example image of dispersed sample (5x magnification). Results and discussion Figure 2 presents the overlays of the Circular Equivalent Diameter (CED) particle size distributions of the two cold remedies by number and volume respectively. The commercial brand contains more particles in the 30 to 200 μm range than the generic brand. The number based distribution indicates the commercial brand also contains more fine particles less than 20 μm in size. Figure 2: Overlay of the number based (top) and volume based (bottom) CED distributions. Morphologi G3-iD application note - MRK1937-01 2

Component identification Both of the cold remedies are made of more than ten components, including the two active pharmaceutical ingredients (APIs) Paracetamol and Phenylephrine. Since pure materials were not available from which to create reference libraries, Raman spectra acquired by the Morphologi G3-ID from 11 different components were identified and these were used as reference library spectra. As examples, the reference spectra for the components 1, 2 and 11 are displayed in figure 3. Figure 3: Raman spectra collected for components 1, 2 and 11. Morphologi G3-iD application note - MRK1937-01 3

Based on the reference spectra, it is possible to classify individual particles as being one of the formulation components. During this classification process a correlation calculation is performed between each particle s spectrum and the reference spectra and a correlation score generated. A score close to 1 indicates a good match whereas a score close to zero indicates no match. Chemical classifications based on these correlation scores were applied to the results to identify the proportion of each component present in the two formulations. The results of the volume based classifications and are presented in figure 4. The three most common components in both formulations were components 1, 2 and 11. The commercial product contains more of component 1 than the generic product whereas the generic product was found to contain more of component 2. Figure 4: Volume based chemical classification results Some of the components were identified by performing an advanced spectrum search using Thermo Scientific s online database ftirsearch.com. Figure 5 shows the result for the identification of Components 1, 2 and 11. Component 2 was found to be the API Acetaminophen (Paracetamol). Components 1 and 11 were found to be different forms of sucrose. Morphologi G3-iD application note - MRK1937-01 4

Figure 5: Result of an Advanced Spectrum Search for components 1, 2 and 11 respectively using Thermo Scientific s online database ftirsearch.com. Morphologi G3-iD application note - MRK1937-01 5

Individual component size distributions Figure 6 presents the overlay of the volume based CED size distributions for the particles that were classed as Paracetamol in each sample along with example particle images. The generic product contains larger particles of Paracetamol than the commercial product. Figure 6: Overlay of the CED particle size distribution for the Paracetamol particles. Whilst component 7 was not found to be very abundant in either sample, on comparing the particle shape of the various components, it was found to be considerably more elongated (needle-like) than the others. Figure 7 presents the scattergram of correlation score to component 7 vs. elongation. It shows that all particles with a high correlation score to reference component 7 do have a high elongation. The particle images shown in the top left of the figure also confirm this. Figure 7: Scattergram of correlation score to component 7 vs. elongation. Morphologi G3-iD application note - MRK1937-01 6

An advanced spectrum search was performed on the reference spectrum for component 7 and it was found to be Aspartame, another form of sweetener (figure 8). The generic product contained significantly more Aspartame while the commercial product contained significantly more Sucrose. This may suggest the generic product uses more artificial sweetener to reduce cost, while the commercial product contains more natural sweetener which may give an improved taste. Figure 8: Result of an Advanced Spectrum Search for component 7 using Thermo Scientific s online database ftirsearch.com. Conclusion Two different cold and flu remedy formulations were analysed on the Morphologi G3-ID. Eleven different chemical components were identified and characterised. The most abundant in both formulations were found to be forms of sucrose and the API Paracetamol. The commercial formulation was found to contain more Paracetamol by volume and presented a larger particle size distribution. Whilst not very abundant in either formulation, Aspartame was also identified in both formulations and was found to have a more needle-like particle shape relative other components. The commercial formulation contained more natural sugar in comparison to the generic product. In the case of the cold and flu remedies the particle size and shape affects the dissolution rate for each component; this may influence the effectiveness of the remedy and may also affect mouth feel and perceived quality. The composition of the formulations may affect taste, and therefore perceived quality, but may also contribute to their effectiveness in relieving cold and flu like symptoms. For an over-the counter cold and flu remedy these differences may be trivial but for formulations requiring submission to the FDA these differences would be critical therefore the ability to identify and characterise different components within a formulation can be critical when reverse engineering a product. Morphologi G3-iD application note - MRK1937-01 7

Malvern Instruments Ltd Enigma Business Park Grovewood Road Malvern Worcestershire UK WR14 1XZ Tel: +44 (0)1684 892456 Fax: +44 (0)1684 892789 Malvern Instruments Worldwide Sales and service centers in over 50 countries for details visit www.malvern.com/contact Malvern Instruments Ltd 2013 more information at www.malvern.com Morphologi G3-iD application note - MRK1937-01 8