A DIVISION OF ULVAC-PHI. Quantera II. Scanning XPS Microprobe

Similar documents
PHI. Scanning XPS Microprobe

A DIVISION OF ULVAC-PHI

PHI 5000 Versaprobe-II Focus X-ray Photo-electron Spectroscopy

A DIVISION OF ULVAC-PHI. Time-of-Flight Secondary Ion Mass Spectrometer with Parallel Imaging MS/MS for Confident Molecular Identification

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

Auger Electron Spectroscopy Overview

Multi-technique photoelectron spectrometer for micro-area spectroscopy and imaging

PHI Model 06-C60 Sputter Ion Gun

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

The Benefit of Wide Energy Range Spectrum Acquisition During Sputter Depth Profile Measurements

Auger Electron Spectroscopy

The solution for all of your

CIG B5. Capitolato Tecnico Technical requirements

Secondary Ion Mass Spectrometry (SIMS)

Large Area TOF-SIMS Imaging of the Antibacterial Distribution in Frozen-Hydrated Contact Lenses

Depth profiling of Organic Films using mixed C60 + and Ar + Ion-Sputtering

Hiden SIMS Secondary Ion Mass Spectrometers. Analysers for surface, elemental and molecular analysis

Application of Surface Analysis for Root Cause Failure Analysis

Dual Beam Helios Nanolab 600 and 650

Characterization of Secondary Emission Materials for Micro-Channel Plates. S. Jokela, I. Veryovkin, A. Zinovev

SNMS. SNMS Applications. Combined SIMS and SNMS

Technical description of photoelectron spectrometer Escalab 250Xi

for XPS surface analysis

ICP-MS. High Resolution ICP-MS.

Mass Spectrometers. for Surface Analysis SURFACE ANALYSIS

TESCAN S New generation of FIB-SEM microscope

Applications of Micro-Area Analysis Used by JPS-9200 X-ray Photoelectron Spectrometer

X-ray Photoelectron Spectroscopy/ Electron spectroscopy for chemical analysis (ESCA), By Francis Chindeka

Methods of surface analysis

Defining quality standards for the analysis of solid samples

Beamline practice at BL01B1 (XAFS) In-situ XAFS measurement of catalyst samples

Elemental analysis by X-ray f luorescence. Sequential benchtop WDXRF spectrometer

Modern Optical Spectroscopy

Photoemission Spectroscopy

ToF-SIMS or XPS? Xinqi Chen Keck-II

An Introduction to Auger Electron Spectroscopy

Secondary Ion Mass Spectroscopy (SIMS)

Characterization of plasma-treated surfaces by X-ray Photoelectron Spectroscopy (XPS)

Clark Atlanta University Center for Surface Chemistry and Catalysis Instrument Capabilities

VASE. J.A. Woollam Co., Inc. Ellipsometry Solutions

Keywords: Abstract. Uwe Scheithauer. Unterhaching

MSE 321 Structural Characterization

Application of the GD-Profiler 2 to the PV domain

MSE 321 Structural Characterization

Auger Electron Spectroscopy (AES)

Gaetano L Episcopo. Scanning Electron Microscopy Focus Ion Beam and. Pulsed Plasma Deposition

S8 TIGER Series 2 for ASTM D 6443

In-situ Ar Plasma Cleaning of Samples Prior to Surface Analysis

The design of an integrated XPS/Raman spectroscopy instrument for co-incident analysis

Secondary ion mass spectrometry (SIMS)

1 Introduction COPYRIGHTED MATERIAL. 1.1 HowdoweDefinetheSurface?

of mass spectrometry

Electrochemical Deposition of Iron Nanoparticles on PPY and H terminated Si substrates. Karan Sukhija Co-op Term # 1 April 28 th, 2005

SCANNING ELECTRON MICROSCOPE

Auger Analyses Using Low Angle Incident Electrons

Introduction to X-ray Photoelectron Spectroscopy (XPS) XPS which makes use of the photoelectric effect, was developed in the mid-1960

Catalysis CAPABILITIES

Dr. Tim Nunney Thermo Fisher Scientific, East Grinstead, UK Dr. Nick Bulloss Thermo Fisher Scientific, Madison, WI, USA Dr. Harry Meyer III Oak Ridge

Nanoscale IR spectroscopy of organic contaminants

Atomic Absorption Spectrometer ZEEnit P series

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

MICRO-TOMOGRAPHY AND X-RAY ANALYSIS OF GEOLOGICAL SAMPLES

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

Nova 600 NanoLab Dual beam Focused Ion Beam IITKanpur

CHARACTERIZATION of NANOMATERIALS KHP

Photoelectron spectroscopy Instrumentation. Nanomaterials characterization 2

Introduction to SIMS Basic principles Components Techniques Drawbacks Figures of Merit Variations Resources

Transmission Electron Microscopy

IONTOF. Latest Developments in 2D and 3D TOF-SIMS Analysis. Surface Analysis Innovations and Solutions for Industry 2017 Coventry

MSN551 LITHOGRAPHY II

Repeatability of Spectral Intensity Using an Auger Electron Spectroscopy Instrument Equipped with a Cylindrical Mirror Analyzer

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

ACCELERATOR MASS SPECTROMETRY AT THE LUND PELLETRON ACCELERATOR

Scanning Kelvin Probe Systems

Practical Surface Analysis

PHI nanotof II TOF-SIMS. 1

IAP NAN of Ukraine activity in. Possible areas of cooperation in. Roman Kholodov, PICS Meeting, Basivka, Ukraine,

Chapter 10. Nanometrology. Oxford University Press All rights reserved.

Microscopy: Principles

MEASUREMENT OF TEMPORAL RESOLUTION AND DETECTION EFFICIENCY OF X-RAY STREAK CAMERA BY SINGLE PHOTON IMAGES

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

IDRaman reader and IDRaman mini: Raster Orbital Scanning (ROS)

X-Ray Photoelectron Spectroscopy (XPS)

Lecture 5-8 Instrumentation

Supporting Information. Effects of Environmental Water Absorption by. Film Transistor Performance and Mobility

XBC300 Gen2. Fully-automated debonder and Cleaner

Spin-resolved photoelectron spectroscopy

Application of surface analysis for root cause failure analysis

Model 2300XP PSL & Process-Particle Wafer Deposition System

Electron beam scanning

Imaging Carbon materials with correlative Raman-SEM microscopy. Introduction. Raman, SEM and FIB within one chamber. Diamond.

XPS/UPS and EFM. Brent Gila. XPS/UPS Ryan Davies EFM Andy Gerger

Solutions for Assignment-8

Supporting Information. For. Preparation and Characterization of Highly Planar Flexible Silver

Applications of XPS, AES, and TOF-SIMS

ABC s of Electrochemistry series Materials Characterization techniques: SEM and EDS Ana María Valenzuela-Muñiz November 3, 2011

Introduction to Fourier Transform Infrared Spectroscopy

Massachusetts Institute of Technology. Dr. Nilanjan Chatterjee

Characteristic X-rays of molybdenum

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

Transcription:

A DIVISION OF ULVAC-PHI Quantera II Scanning XPS Microprobe

X-ray Photoelectron Spectroscopy (XPS/ESCA) is the most widely used surface analysis technique and has many well established industrial and research applications. XPS provides quantitative elemental and chemical state information from surfaces and thin film structures. XPS is applied to a diverse range of materials applications including: polymers, metals, catalysts, thin films, photovoltaics, batteries, wear coatings, nanomaterials, semiconductor devices, magnetic storage media, display technology, and biomedical devices. The Quantera II is built upon Physical Electronics (PHI) revolutionary scanning XPS microprobe instrument platform that includes: a patented micro-focused scanning x-ray source, patented dual beam charge neutralization technology, a floating column ion gun for optimized XPS sputter depth profiling, flexible robotic sample handling, and a fully automated internet ready instrument platform. The Quantera II increases the performance and productivity of these revolutionary technologies, providing the highest performance XPS system available to meet your current and future XPS needs.

THE SCANNING XPS MICROPROBE ADVANTAGE Quartz Crystal Monochromator Energy Analyzer Raster Scanned Electron Gun Unique Capabilities PHI s scanning XPS microprobe instrument platform provides secondary electron images (SXI) generated by scanning a focused 10 μm x-ray beam across the sample. These SXI images have a contrast mechanism that is dominated by photoelectron yield (composition), and therefore often reveal features that are not visible optically or related to topography. SXI images provide a high degree of confidence in locating small features for analysis. The micro-focused x-ray beam defines the analysis area pattern for large area spectroscopy, micro area spectroscopy, chemical state imaging, and depth profiling. Analyzer Input Lens Multi-Channel Detector Sample Al Anode PHI s patented scanning XPS microprobe technology delivers a micro-focused, raster scanned, monochromatic x-ray beam to the sample surface providing unique and powerful capabilities to our users.

SXI Multi-Area Spectroscopy MICRO AREA XPS Microprobe Workflow X-ray beam induced secondary electron image (SXI) from a polymer film reveals the presence of unexpected contaminants on the samples surface. Micro area spectra reveal the composition of the unknown contaminants. Chemical Imaging Elemental images show the smaller features in the secondary electron image do not contain fluorine. A micro area spectrum from the smaller features, obtained using a 10 μm diameter x-ray beam, identifies the presence of a second contaminant that contains Zn. A x-ray beam induced secondary electron image immediately revealed the presence of unexpected localized contaminants on a polymers surface. Micro area spectra obtained with a 20 μm diameter x-ray beam identified a fluorocarbon contaminant in a few minutes. Elemental maps show the smaller features in the secondary electron image do not contain fluorine. A micro area spectrum from the smaller features, obtained using a 10 μm diameter x-ray beam, identifies the presence of a second contaminant that contains Zn.

ROBUST AUTO ANALYSIS High Productivity Whether you are analyzing a thin polymer sheet, a large plastic lens, a steel razor blade, or electrically isolated solder bumps; the instrument set-up is the same. Point and click at an optical image to select the analysis areas. Then start the analysis with the dual beam neutralizer and the auto-z functions activated to provide automatic sample alignment and charge neutralization. There is no individual sample tuning, no concerns over sample composition and size, and no worries about walking away from the instrument and letting it automatically collect data from all your samples. No Special Sample Mounting or Masking Robust Automatic Sample Alignment ( Auto-Z ) Hands-Off Charge Neutralization

THIN FILM ANALYSIS Optimized Configuration 2 kev Ar sputter depth profile of the 10 kev C 60 depth profile of a 50/50 surface species on a solder ball used for rapamycin and PLGA film showing semiconductor packaging segregation of the rapamycin to the surface of the coating. Inorganic Thin Film Analysis Organic Thin Film Analysis 0-5 kv floating column Ar ion gun Optional C 60 cluster source ion gun Low voltage depth profiling for ultra Optional Ar 2500 cluster source thin films ion gun Bend in column to stop neutrals Mass filtered ion beam Compucentric Zalar rotation Bend in column to stop neutrals Micro Area depth profiling Sputters many polymer and organic Multi-point depth profiling materials without damaging their chemistry A focused x-ray beam, high sensitivity spectrometer, high performance floating column ion gun, turnkey dual beam charge neutralization, compucentric Zalar rotation, and advanced data reduction algorithms provide the highest performance XPS depth profiling capability available. Applications include: semiconductor thin film structures, magnetic media thin films, optical coatings, decorative coatings, wear coatings and, with the optional C60 or GCIB cluster ion beams, polymer and organic thin films such as time release drug coatings and organic LED films.

A DIVISION OF ULVAC-PHI Physical Electronics - USA ULVAC-PHI Inc. - Japan Phone: 952-828-6100 Phone: 81-467-85-4220 Email: sales@phi.com www.phi.com Email: Web: webmasterjp@phi.com www.ulvac-phi.co.jp Web: Standard Features XPS microprobe with 7.5 μ m spatial resolution Optional Accessories High performance floating column ion gun High sensitivity electrostatic High speed snapshot depth detection optics profiling mode Dual beam charge Quantitative chemical state neutralization mapping Robotic sample handling Automated Angle Dependent profiles Samples up to 100 mm diameter and 25 mm thick PHI MultiPak data reduction software Two internal sample parking stations Sample Positioning Station Dedicated turbo pump for Ar ion gun Hot/Cold sample stage Cold sample introduction apparatus Sample transfer chamber to external test stations C60 sputter ion gun Ar 2500 Gas Cluster Ion Beam (GCIB)