A fast triple GEM detector for high-rate charged-particle triggering

Similar documents
A Complete Simulation of a Triple-GEM Detector

A complete simulation of a triple-gem detector

Performance of a triple-gem detector for high-rate particle triggering

A Triple-GEM Telescope for the TOTEM Experiment

GEM-based photon detector for RICH applications

Electron transparency, ion transparency and ion feedback of a 3M GEM

Advances in the Micro-Hole & Strip Plate gaseous detector

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

arxiv:physics/ v2 27 Mar 2001

Nuclear Instruments and Methods in Physics Research A

CCD readout of GEM-based neutron detectors

The Cylindrical GEM detector for the KLOE-2 Inner Tracker

Simulation of GEM-TPC Prototype for the Super-FRS Beam Diagnostics System at FAIR

HIGH energy physics research requires a constant improvement

GEM upgrade of the ALICE TPC. Markus Ball Physics Department E18 Technische Universität München On Behalf of the ALICE TPC upgrade

Performance of triple GEM tracking detectors in the COMPASS experiment

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Breakdown limit studies in high-rate gaseous detectors

GEM: A new concept for electron amplification in gas detectors

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Micro-pattern gaseous detectors

Detectors in Nuclear and High Energy Physics. RHIG summer student meeting June 2014

Digital Hadron Calorimetry for the Linear Collider using GEM Technology

Development of a Time Projection Chamber with GEM technology in IMP. Herun yang Gas detector group

Angular resolution of the gaseous micro-pixel detector Gossip

Discharge studies in Micromegas detectors in low energy hadron beams

Neutron Structure Functions and a Radial Time Projection Chamber

ALICE TPC upgrade for High-Rate operations

3D Simulation of Electron and Ion Transmission of GEM-based Detectors

Physics studies to define the CMS muon detector upgrade for High-Luminosity LHC

Microscopic Simulation of GEM Signals

A pattern recognition method for the RICH-based HMPID detector in ALICE

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

THE MULTIGAP RESISTIVE PLATE CHAMBER. Abstract

Precision Calibration of Large Area Micromegas Detectors Using Cosmic Muons

Evaluation and reduction of ion back-flow in multi-gem detectors

THE MULTIGAP RESISTIVE PLATE CHAMBER

Performance test of triple GEM detector at CERN n_tof facility

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

Recent advances in gaseous imaging photomultipliers

Characterization and installation at FTU (ENEA) of a fast neutron flux monitor;

Track Resolution Measurements for a Time Projection Chamber with Gas Electron Multiplier Readout

Results from Silicon Photo-Multiplier neutron irradiation test

arxiv: v1 [physics.ins-det] 7 Dec 2018

Study of GEM-like detectors with resistive electrodes for RICH applications

Flux and neutron spectrum measurements in fast neutron irradiation experiments

Position sensitive detection of thermal neutrons with solid state detectors (Gd Si planar detectors)

Response uniformity of a large size RPC

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

Recent advances in gaseous imaging photomultipliers

arxiv: v1 [physics.ins-det] 28 Mar 2016

Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency

Improvement of Spatial Resolution by Selfconsistent Full Muon Track Reconstruction in Gaseous Detectors

Particle Energy Loss in Matter

PoS(EPS-HEP2015)232. Performance of a 1 m 2 Micromegas Detector Using Argon and Neon based Drift Gases

ALICE A Large Ion Collider Experiment

Measurement of material uniformity using 3-D position sensitive CdZnTe gamma-ray spectrometers

Lecture 18. New gas detectors Solid state trackers

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

A progress report on the development of the CsI-RICH detector for the ALICE experiment at LHC

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

Assessment of the Čerenkov light produced in a PbWO 4 crystal by means of the study of the time structure of the signal

NEW DEVELOPMENTS IN GASEOUS DETECTORS. Fabio Sauli. CERN, Geneva, Switzerland

GEM operation in helium and neon at low temperatures

Triple GEM Detectors for the Forward Tracker in STAR

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

GEM-based gaseous photomultipliers for UV and visible photon imaging

Charge readout and double phase

arxiv:physics/ v2 [physics.ins-det] 31 Oct 2003

Physics sources of noise in ring imaging Cherenkov detectors

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

New irradiation zones at the CERN-PS

A proposal to study gas gain fluctuations in Micromegas detectors

Spatial resolution measurement of Triple-GEM detector and diffraction imaging test at synchrotron radiation

Micro Pixel Chamber with resistive electrodes for spark reduction

Siberian Branch of Russian Academy of Science. A. Buzulutskov, A. Bondar, L. Shekhtman, R. Snopkov, Yu. Tikhonov

R&D on Astroparticles Detectors. (Activity on CSN )

Optimization of the Gas Flow in a GEM Tracker with COMSOL and TENDIGEM Development. Presented at the 2011 COMSOL Conference

Summer Student Project: GEM Simulation and Gas Mixture Characterization

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

SIMULATION OF CHARGED PARTICLE DETECTORS FOR FUTURE UPGRADES OF THE CMS EXPERIMENT AT THE LARGE HADRON COLLIDER

Micro Pixel Chamber Operation with Gas Electron Multiplier

Part II. Momentum Measurement in B Field. Contribution from Multiple Scattering. Relative Momentum Error

Rate Dependency Study on Gas Electron Multiplier Gain

arxiv:physics/ v1 [physics.ins-det] 2 Aug 2000

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH GAS DETECTORS: ACHIEVEMENTS AND TRENDS. Fabio Sauli. CERN, CH-1211 Geneva, Switzerland ABSTRACT

The heavy-ion magnetic spectrometer PRISMA

The Luminosity Monitor

PoS(RPC2012)034. Simulation studies on the Effect of SF 6 in the RPC gas mixture

Performance studies of MicroMegas for the ATLAS experiment

Triple GEM gas detectors as real time fast neutron beam monitors for spallation neutron sources

Charge ampli"cation and transfer processes in the gas electron multiplier

Near detector tracker concepts. D. Karlen / U. Vic. & TRIUMF T2K ND280m meeting August 22, 2004

polarized HCAL ECAL2 ECAL1 HCAL1

Study of GEM-TPC Performance in Magnetic Fields

The TRD of the CBM experiment

Digital Imaging Calorimetry for Precision Electromagnetic and Hadronic Interaction Measurements

ALICE-TPC upgrade with GEMs. Jens Wiechula for the ALICE TPC Upgrade collaboration

Transcription:

Nuclear Instruments and Methods in Physics Research A 478 (2002) 245 249 A fast triple GEM detector for high-rate charged-particle triggering G. Bencivenni a, W. Bonivento b,1, C. Bosio c, A. Cardini b, *, G. Felici a, A. Lai b, F. Murtas a, D. Pinci b,d, B. Saitta b,d,1, L. Satta a, P. Valente a a Laboratori Nazionali di Frascati - INFN, Frascati, Italy b Sezione INFN di Cagliari, Cittadella Universitaria di Monserrato, Strada Prov.le per Sestu Km. 1,00, 09042 Monserrato, Cagliari, Italy c Sezione INFN di Roma, Roma, Italy d Universit "a degli Studi di Cagliari, Cagliari, Italy Abstract Triple-GEM detectors with pad readout has been tested at the CERN PS T11 Hadron Beam Facility. A time distribution RMS of6 ns has been obtained with an Ar/CO 2 /CF 4 (60/20/20) gas mixture, achieving a substantial improvement with respect to Ar/CO 2 (70/30), where an RMS of10 ns was obtained. This resulted in an efficiency of about 96% in a 25 ns time-window (and a total efficiency of99.7%), suggesting that these detectors could be interesting devices for triggering at the typical LHC interaction rate. r 2002 Elsevier Science B.V. All rights reserved. PACS: 29.40; 29.40.C Keywords: Gas electron multiplier; GEM; High rate triggering; Tetrafluoromethane 1. Introduction *Corresponding author. Tel.: +39-070-6754837; fax: +39-070-510212. E-mail address: alessandro.cardini@cern.ch (A. Cardini). 1 Now at CERN, EP Division, Geneva, Switzerland. A gas electron multiplier (GEM) [1] is a thin metal clad Kapton foil perforated with a high density ofholes. By applying a suitable voltage difference between the two sides ofthe GEM, an electric field with an intensity as high as 100 kv/cm is produced inside the holes. By means ofan appropriate electric field, electrons produced above the GEM are collected into the holes and are multiplied thanks to the high field. A chargedparticle detector can be made by inserting a GEM between a cathode and a board equipped with charge collecting electrodes and by flushing an appropriate gas mixture in this structure. Two or more GEMs can be stacked one above the other, allowing to reach a higher gain and to decrease the spark probability ofthe structure for a given total gain. In particular triple-gem structures [2] seem very promising devices to be used at high luminosity colliders. The distribution ofthe time response ofgem based detectors working with an Ar/CO 2 (70/30) gas mixture was measured to have an RMS of 10 ns [3] when no electronics slewing corrections are performed. In order to improve the detector time resolution a detailed study on the electric 0168-9002/02/$ - see front matter r 2002 Elsevier Science B.V. All rights reserved. PII: S 0168-9002(01)01764-8

246 G. Bencivenni et al. / Nuclear Instruments and Methods in Physics Research A 478 (2002) 245 249 fields, detector geometry and gas mixtures has been performed and results are reported in this paper. Three similar detector prototypes (Fig. 1) were built using CERN standard 10 10 cm 2 GEMs [4]. Each GEM has bi-conical holes with 70 mm (50 mm) external (internal) diameter with a pitch of140 mm. In each detector three GEMs are stacked one above the other at 2 mm distance (the transfer gaps) and positioned 1 mm above the readout pads (the induction gap). On the top of the stack a cathode plane defines a 3 mm-thick ionization gap. The readout board is segmented in 6 16 mm 2 pads. Fifteen pads in each detector are connected to fast preamplifiers having a gain of 10 mv/fc, a peaking time of 5 ns and an electronic noise ofabout 1300e RMS at zero input capacitance. The test ofthese detectors was performed during October 2000 at the CERN PS T11 hadron beam facility using charged pions of energy between 2 and 4 GeV at an intensity ofabout 1 khz/cm 2 : Scintillators equipped with constant fraction discriminators were used to provide a precise common stop signal to the TDCs. 3. Choosing the working conditions 2. Detector, electronics and test setup The intrinsic time spread ofa GEM-based detector is sðtþ ¼1=nv drift ; where n is the average number ofclusters per unit length and v drift is the electron drift velocity in the ionization gap. This arises from the probability distribution PðxÞ ¼ ne nx ofthe distance ofthe cluster produced closer to the first GEM, which gives sðxþ ¼1=n: To achieve a good time resolution, high yield and fast gas mixtures are needed. However, a low efficiency for primary electron detection could worsen this time resolution. To reduce this effect it is important to adjust the electric fields to maximize the detector transparency to electrons and to reach a sufficient electron multiplication in the GEM holes. For each GEM the effective gain depends on [5]: * the efficiency ofcollecting primary electrons into the hole, which decreases for high electric field above the GEM because ofthe defocusing ofthe field lines (some electrons could hit the GEM upper electrode); Fig. 1. (a) The three GEMs glued on the G10 frames of different thickness. (b) Readout pads mounted on the gas-tight G10 box. (c) The three GEMs stacked in the box.

G. Bencivenni et al. / Nuclear Instruments and Methods in Physics Research A 478 (2002) 245 249 247 * the capability ofextracting secondary electrons from the holes, which increases while increasing the intensity ofthe electric field below the GEM; * the electron multiplication into the holes, which increases exponentially with the voltage applied to the GEM electrodes. Two different gas mixtures were tested, Ar/CO 2 (70/30) and Ar/CO 2 /CF 4 (60/20/20). The electron drift velocity for both mixtures is reported in Fig. 2. 4. Detector performances 4.1. Transparency optimization Scans in the drift (E d ) and in the transfer fields (E t ¼ E t1 ¼ E t2 ) were performed with the purpose ofmaximizing the detector efficiency in a 25 ns window. 2 At low E d the efficiency decreases due to the small drift velocity and the electron diffusion in the gas. At high E d efficiency losses are due to the field-lines defocusing effect (see Fig. 3a). For the transfer fields it was observed that at low E t the efficiency decreases due to the poor electron extraction capability from the lower side ofthe GEM. At high E t the extraction efficiency saturates but the defocusing effect on the GEM below starts to appear (see Fig. 3b). The optimal working point was found at E d ¼ 3 kv/cm, E t ¼ 4 kv/cm and E i ¼ 5 kv/cm, where a total efficiency of96% was reached. The value chosen for E i is a compromise between a good electron extraction capability from the last GEM and a low sparking probability in the induction gap. It should be noted however that in this case the GEMs gain were kept at moderate values, with only 390 V on each GEM, and in these conditions the detector is not at full efficiency. 2 Only the scans performed with Ar/CO 2 /CF 4 (60/20/20) are described here since no dependence on the gas mixture has been found. Fig. 2. Measured electron drift velocity for Ar/CO 2 (70/30) [6] and Ar/CO 2 /CF 4 (60/20/20) [7]. 4.2. Total gain optimization In order to increase the first cluster detection probability, it is important to have a high detector total gain and a high electron transparency on the first GEM. A scan on the voltage ofthe first GEM (V gem ) was performed while keeping the other two GEMs supplies at moderate values (390 V). This was done to avoid possible discharges on the last GEM due to the high total charge and to reduce the amplification ofthe ionization created between the first and the second GEMs, which could generate hits early in time. Efficiency in a 25 ns time window increases with the voltage supply ofthe first GEM and seems to saturate to a value close to 90% for Ar/CO 2 (70/ 30) and to 96% for Ar/CO 2 /CF 4 (60/20/20) (Fig. 4). It was also found that in the configuration where the electric fields increase progressively by 30% from gap to gap (the so-called Field Scaling configuration) a 94% efficiency is obtained at low values of V gem (390 V) (Fig. 4b), indicating that it might be possible to have an efficient detector working in safer conditions for what concerns the spark probability.

248 G. Bencivenni et al. / Nuclear Instruments and Methods in Physics Research A 478 (2002) 245 249 Fig. 3. Efficiency (total and in a 25 ns window) as a function of the intensity of(a) the drift field E d (for E t ¼ 2:2 kv/cm) and of (b) the transfer fields E t (for E d ¼ 3 kv/cm). Fig. 4. Efficiency in a 25 ns window as a function of V gem ; using Ar/CO 2 (70/30) (a) and Ar/CO 2 /CF 4 (60/20/20) (b). The efficiency measured in the Field Scaling configuration is also reported. The time spectra recorded with the two gas mixtures, for the two runs with the highest efficiencies, are shown in Fig. 5. A substantial improvement in the spread ofthe distribution was obtained using the CF 4 -based gas mixture, reducing the RMS from 10 to 6 ns. 5. Conclusions Three-GEM detectors prototypes equipped with pad readout and supplied with a mixture ofar/ CO 2 /CF 4 (60/20/20) at STP have shown very good time performances, resulting in a time distribution

G. Bencivenni et al. / Nuclear Instruments and Methods in Physics Research A 478 (2002) 245 249 249 stability ofthese detectors under high chargedparticle rate and their ageing properties are in progress. A fine tuning ofgas mixture, electric field configuration and detector geometry might allow additional improvements on the time resolution. Acknowledgements The authors would like to thank F. Sauli for useful discussions. This work would not have been possible without the support ofthe technical staff both at INFN Cagliari and at LNF, and in particular of: M. Arba and M. Tuveri (INFN Cagliari) for the realization ofthe mechanics ofthe Cagliari prototype; D. Marras (INFN Cagliari) for the design and the assembly of the front-end electronics ofthe Cagliari prototype; B. Ortenzi (LNF) for the design of the detector box of the Frascati prototypes; E. Iacuessa and S. Valeri for the realization ofthe mechanics ofthe Frascati prototypes; the LNF Electronics Pool for the realization ofthe front-end electronics ofthe Frascati prototypes. References Fig. 5. Time distribution oftriple-gem detectors using Ar/ CO 2 (70/30) (a) and Ar/CO 2 /CF 4 (60/20/20) (b). m GAUSS and s GAUSS are respectively the mean and the standard deviation of the gaussian fit ofthe peak. [1] F. Sauli, Nucl. Instr. and Meth. A 386 (1997) 531. [2] S. Bachmann, et al., Nucl. Instr. and Meth. A 470 (2001) 548. [3] A. Bressan, J.C. Labbe, P. Pagano, L. Ropelewski, F. Sauli, Nucl. Instr. and Meth. A 425 (1999) 262. [4] A. Gandi, Laboratory ofphotomechanical Techniques and Printed Circuits, EST-SM-CI Section, CERN, Geneva, Switzerland. [5] C. Richter, et al., Nucl. Instr. and Meth. A 461 (2001) 38, and references therein. [6] S. Bachmann, et al., Nucl. Instr. and Meth. A 438 (1999) 376. [7] U. Becker, et al., Gas R&D Home Page, http://cyclotron. mit.edu/drift. RMS of6 ns and an efficiency of96% in a 25 ns time window. Studies aiming to investigate the