DETERMINATION OF UPTAKE RATES FOR VOCs IN AMBIENT AIR BY USING AXIAL TYPE THERMAL DESORPTION PASSIVE TUBES

Similar documents
Magnitudes of Back Diffusion During Long-Term Diffusive Sampling of Volatile Organic Compounds Using Carbotrap and Chromosorb 106

Vapor Intrusion Sampling Options: Performance Data for Canisters, Badges, and Sorbent Tubes for VOCs

Raw Material Finished product By product Exposure standards Length of shift Physical environment

THEORETICAL DETERMINATION OF THE SAMPLING RATES OF DIFFUSION SAMPLERS FOR VOCS AND ALDEHYDES

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

TDTS 16 Round-the-clock, on-line and cryogen-free monitoring of hydrocarbons from acetylene to trimethylbenzene in ambient air

A STUDY OF VOLATILE ORGANIC CARBON POLLUTION ON A UNIVERSITY CAMPUS DUE TO TRAFFIC

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

VINYL CHLORIDE. Recommended by NIOSH, partially evaluated by OSHA Laboratory.

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

Electronic Supplementary Material Experimentally Validated Mathematical Model of Analyte Uptake by Permeation Passive Samplers

EMICODE Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No. G12871B_02

Real-Time Detection: From Gisclard et al.: A Simple Device for Air Analysis. AIHA Quarterly, 14(1):23-25 (1953)

Test Report- VOC emission regulations in Europe

Test Report- VOC emission regulations in Europe

Air Monitoring Sorbent Pens. For Environmental and IH Applications

HYDROCARBONS, AROMATIC 1501

Application Note 032

VOC EMISSION TEST REPORT ISO 16000

TO-17 Extending the Hydrocarbon Range above Naphthalene for Soil Vapor and Air Samples Using Automated

VOC EMISSION TEST REPORT BREEAM NOR

Test Report- VOC emission regulations in Europe

Copyright 2009 PerkinElmer LAS and CARO Analytical Services, Inc.

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

SURVEY OF CHEMICALS EMISSION FACTORS FROM BUILDING MATERIALS FOR INTERIORS

Thermal Desorption Technical Support. Note 56: TD-GC/MS analysis of vapour-phase organic compounds for materials emissions testing.

Supplement of Non-methane hydrocarbon variability in Athens during wintertime: the role of traffic and heating

Test Report. Tremco-Illbruck GmbH & Co KG. Product Emissions Test (AgBB/DIBt Test Protocol) Butyl und Bitumenprimer. June 2011

Thermal Desorption Technical Support

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Test Report- VOC emission regulations in Europe

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

Test Report in accordance CDPH-IAQ

SELECTED ION FLOW TUBE MASS SPECTROMETRY. Interscience Expert Center: VIP Meeting 15 Sept. 2009

Test Report. Glava AS. Emission test of Ecophon Venus according to M1 classification. October / November Smedeskovvej 38, DK-8464 Galten

VOC TEST REPORT CDPH

Test Report ROMA USA LLC. Product Emissions of Furniture in accordance with. Cradle to Cradle section 5.8 ECODOMUS SATIN BASE TR.

VOC TEST REPORT CDPH

method for monitoring exposure to gasoline vapour in air revision 2002

M1 Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04

Optimization of a Polydimethylsiloxane Based Passive Sampler of Common Household Volatile Organic Compounds

Real Time On-Site Odor and VOC Emission Measurements Using a znose

Test Report- VOC emission regulations in Europe

The Application of Method TO-15 to Naphthalene Measurements in Indoor Air

INNOVATIVE PRODUCTS, SUPERIOR SUPPORT. Presenter: Anne Jurek, Senior Applications Chemist, EST Analytical

EVALUATION OF A PID-BASED PORTABLE DETECTION SYSTEM FOR TVOC AS AN INDOOR POLLUTION ANALYZER

Evaluation of Indoor Exposition to Benzene, Toluene, Ethylbenzene, Xylene, and Styrene by Passive Sampling with a Solid-Phase Microextraction Device

EMICODE Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04

GAW Expert Workshop VOC, C. Plass-Dülmer et al., FEHp-B 1

Test Report in accordance CDPH-IAQ

VOC TEST REPORT M1. 6 April Regulation or protocol Conclusion Version of regulation or protocol

Time Integrated Indoor Air Sampling using a Membrane Based Passive Sampler

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

VOC TEST REPORT EMICODE

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Breath Analysis Investigating the Human Volatome by ATD-GCMS

VOC TEST REPORT M1. 23 October Regulation or protocol Conclusion Version of regulation or protocol

Characterising Volatile Organic Compounds from Sewer Emissions by Thermal Desorption coupled with Gas- Chromatography-Mass Spectrometry

VOC measurements in ambient air using Selected Ion Flow Tube Mass Spectrometry-automation and calibration considerations

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Application Note. Application Note 081 Innovative Cryogen-Free Ambient Air Monitoring in Compliance with US EPA Method TO-15. Abstract.

Date: March 6, 2008 RWDI Reference #: W B Pages (Including Cover):

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

VOC TEST REPORT AgBB

VOC TEST REPORT EMICODE

Site Specific Conditional Sampler Garfield County, Colorado. VOC Data Summaries. Prepared for

Test Report. Muovihaka Oy. Product Emissions in accordance with the Swedish Building Material Assessment Ultima graphite.

WP3: In-situ chemical, physical and optical properties of aerosols. WP4: Trace gases networking: Volatile organic carbon and nitrogen oxides

Watercare Air Quality Group March 2002 APPENDIX A. Monitoring Site Location Diagrams

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

VOC TEST REPORT Indoor Air Comfort GOLD

Sampling for Gases and Vapors

Determination of Benzene, Toluene, Ethylbenzene and Xylene in River Water by Solid-Phase Extraction and Gas Chromatography

TDTS. Keywords. Introduction. TD Operation; Calibration; Impedance; Discrimination

VOC TEST REPORT CDPH

DEVELOPMENT OF A SENSITIVE THERMAL DESORPTION GC-MS METHOD USING SELECTIVE ION MONITORING FOR A WIDE RANGE OF VOCS

VOC TEST REPORT Indoor Air Comfort GOLD

Tar analysis by Solid Phase Adsorption (SPA) associated with Thermal Desorption (TD) and Gas Chromatography (GC) analysis

VOC TEST REPORT Tarkett Indoor Air Quality

AIR. Ambient, Indoor, Workplace Air and Stack Emissions Proficiency Testing Scheme. Sample Preparation Instructions Round 1

VOC TEST REPORT M1. 16 August Regulation or protocol Conclusion Version of regulation or protocol

VOC TEST REPORT Indoor Air Comfort

Intertek Environmental VOC Emissions

VOC TEST REPORT Indoor Air Comfort

EPA TO-17 Volatile Organic Compounds

VOC TEST REPORT Indoor Air Comfort GOLD

VOC EMISSION TEST REPORT Indoor Air Comfort

VOC EMISSION TEST REPORT Indoor Air Comfort GOLD

A Single-Method Approach for the Analysis of Volatile and Semivolatile Organic Compounds in Air Using Thermal Desorption Coupled with GC MS

A Single Calibration for Waters and Soil Samples Performing EPA Method Anne Jurek Applications Chemist

THERMAL DESORPTION CAPABILITY DEVELOPMENT FOR ENHANCED ON-SITE HEALTH RISK ASSESSMENT: HAPSITE ER PASSIVE SAMPLING IN THE FIELD

Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air. Second Edition. Compendium Method TO-17

VOC EMISSION TEST REPORT Indoor Air Comfort GOLD

Emission measurements according to, M1 (3 appendices)

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

Hexane isomers (except n-hexane) and methylcyclopentane

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

VOC TEST REPORT Indoor Air Comfort GOLD

SAB Soil Vapour Forum July 8, Overview of Soil Vapour Assessment From A Laboratory Industry Perspective

Transcription:

DETERMINATION OF UPTAKE RATES FOR VOCs IN AMBIENT AIR BY USING AXIAL TYPE THERMAL DESORPTION PASSIVE TUBES Mihriban Yılmaz Civan, Öznur Kuntasal and Gürdal Tuncel 1 1

OUTLINE Introduction Importance and scope of the study Passive Tube Theory Material & Methods Sampling Site and Duration Sample Preparation&Handling Analytical Techniques Performance Evaluation Results & Discussions Uptake Rate Meteoroligical Parameters Future Works 2 2

INTRODUCTION Uptake rate for VOCs VOCs: Organic compounds having vapor pressure >10-4 atm @ 25 C 0 and 1 atm 3 3

Introduction... VOCs are important because: Precursors of photochemical reactions with NO x O 3 adverse health effects (iritation to noise and throat, asthama and bronchitis) and damage vegetation 4 4

Introduction... toxic substances known or suspected carcinogen VOC Conc. exhaust emmisions industrial process evaporation 5 5

Introduction... Sampling and Analyzing Techniques: Use near real time instrument (infrared spectrometers or portable GC) sample from air using Canister Adsorbtion on selective sorbents (passive and active sampling) 6 6

Introduction... PASSIVE (DIFFUSIVE) SAMPLING: taking samples by a physical process (diffusion and permeation) 7 7

Introduction... Passive Sampling Theory: Adsorbtion of the sample onto adsorbent surface through the air movement Fick s First Law Analyte Conc( ppm) = U. R. ( ng / M a ( ng) ppm min) t(min) 8 8

Introduction... Uptake rate (UR): Experimental U.R (exposure chamber or online GC system) Ideal U.R (Diffusion Coefficent (D) is obtained from literature) Uptake Rate ( ng / ppm min) = D ( cm 2 2 / s) A ( cm ) L ( cm) 9 9

Introduction... 10 10

MATERIALS & METHODS Sampling Site Bursa Station Urban Sampling Passive Sampling Active Sampling (Hourly measurement) 11 Continous and un interrupted data obtained 11

Sample Preparation and Handling Thermally desorber stainless steel passive tubes Advantage: 9 not require solvent extraction 9 have chance to select sorbent 9 leave long term in sampling area without breakthrough 9 less affected from relative humidity 12 12

Sample Preparation and Handling Sorbent: Chromosorb 106 by Supelco Characteristics: suitable analyte volatility range for VOC in concern Hydrophobic analyte volatility range boiling point 50 0 C 200 0 C maximum temperature: 250 0 C specific surface area : 750 m 2 /g 13 13

Sampling Methodology Condition of tubes Swagelock-type screw caps with combined PTFE ferrule Sealed glass tubes filled with silica gel and charcoal at the bottom Deep-freeze in the laboratory Glass sealed jar filled with activated charcoal 14 14

Sampling Methodology European Standard (EN) 13528 Shelters made from aluminum Replacing the sampling cap with diffusion part placed between 1.6-2.0 m from ground level Field /Lab Blanks 15 15

16 16

Methodology... Analysis of collected samples on sorbents Organics (VOCs) GC-FID-Unity TD 17 17

Methodology... GC-FID coupled with Unity Air Server Markes Unity-Air Server Thermal Desorber HP 6890 Dual Column GC coupled to FID with Dean Switch System 18 18

Methodology... (GC-FID) 19 19

Methodology... (GC-FID) 20 20

Methodology... Calibration gas standard: 148 VOCs (C 2 -C 12 ) from AAQD of Environment Canada 95 point calibration Sorrogate Standard: 1-Bromoflourobenzene 21 21

Methodology... Typical Calibration Standard Chromotogram 22 22

Methodology... Typical Sample Chromotogram 23 23

Performance Evaluation Detection Limit 0.21 μg m -3 (0.08 μg m -3-0.31 μg m -3 ) Recovery/Desorption Efficiency 93.6% (80-100%) Precision 7.7% (2.6-15.7%) Sampling Stability?? 24 24

25 25

RESULT Exposure Date Number of active samples Number of passive tubes 5-19 Oct.2005 258 (77%) 3 21-29 Oct.2005 173 (90%) 5 1-7 Nov.2005 84 (58%) 4 03-10 Apr.2006 144 (86%) 6 13-20 Apr2006 152 (90%) 4 25.Apr 03 May.2006 181 (100%) 3 26 26

Uptake Rates for BTEX 27 27

Uptake Rates for NMHCs 28 28

Meteorological Parameters: 90 18 Relative Humidity (%) 85 80 75 70 65 60 Temperature (C) 16 14 12 10 8 55 6 50 5-19 Oct 2005 21-29 Oct 2005 1-7 Nov 2005 Wind Speed (m/sec) 03-10 Apr 2006 2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 13-20 Apr2006 25 Apr- 0 3 May2006 4 5-19 Oct 2005 21-29 Oct 2005 1-7 Nov 2005 03-10 Apr 2006 13-20 Apr2006 25 Apr- 03 May2006 5-19 Oct 2005 21-29 Oct 2005 1-7 Nov 2005 03-10 Apr 2006 13-20 Apr2006 25 Apr- 03 May2006 29 29

UPTAKE RATE COMPOUND UPTAKE RATE (ng ppb -1 min -1 ) Benzene 0.323 Toluene 0.562 Ethylbenzene 0.718 m&p-xylene 1.535 o-xylene 1.123 30 30

UPTAKE RATE COMPOUND UPTAKE RATE (ng ppb -1 min -1 ) 1-Heptene 0.3219 3-M-Hexane 0.257 Heptane& cis-3-heptene 0.568 n-hexane 0.189 n-nonane 0.543 n-probylbenzene 0.351 31 31

Future Works Long term sampling with canister Meterological parameter QA/QC complete 32 32