Keysight Technologies Measuring Substrate-Independent Young s Modulus of Low-k Films by Instrumented Indentation. Application Note

Similar documents
Keysight Technologies Young s Modulus of Dielectric Low-k Materials. Application Note

Keysight Technologies Instrumented Indentation Testing with the Keysight Nano Indenter G200. Application Note

Performance and Control of the Agilent Nano Indenter DCM

Keysight Technologies Oxygen-Free High-Resolution Electrochemical SPM. Application Note

Keysight Technologies Measuring Stress-Strain Curves for Shale Rock by Dynamic Instrumented Indentation. Application Note

Keysight Technologies Mechanical Testing of Shale by Instrumented Indentation. Application Note

Keysight Technologies Measurement Uncertainty of VNA Based TDR/TDT Measurement. Application Note

Session 15: Measuring Substrate-Independent Young s Modulus of Thin Films

Keysight Technologies Carbon Nanotube Tips for MAC Mode AFM Measurements in Liquids. Application Note

Keysight Technologies Nanomechanical Mapping of Graphene Quantum Dot-Epoxy Composites Used in Biomedical Applications

Keysight Technologies Contact Deformation of LiNbO3 Single Crystal: Dislocations, Twins and Ferroelectric Domains.

Keysight Technologies In situ Electrochemical Measurement Using 9500 AFM. Application Note

Keysight Technologies Introduction to SECM and Combined AFM-SECM. Application Note

Agilent EEsof EDA.

Dynamic Mechanical Analysis (DMA) of Polymers by Oscillatory Indentation

International Standardization for Measurement and Characterization of Nanomaterials

2017 Source of Foreign Income Earned By Fund

CONSIDERATIONS ON NANOHARDNESS MEASUREMENT

Session 11: Complex Modulus of Viscoelastic Polymers

Determining the Elastic Modulus and Hardness of an Ultrathin Film on a Substrate Using Nanoindentation

Keysight Technologies Measuring Polarization Dependent Loss of Passive Optical Components

Determining thermal noise limiting properties of thin films

IN QUALITATIVE ANALYSIS,

READY TO SCRAP: HOW MANY VESSELS AT DEMOLITION VALUE?

Aerospace part number guide

Application of nanoindentation technique to extract properties of thin films through experimental and numerical analysis

Nonlinear Finite Element Modeling of Nano- Indentation Group Members: Shuaifang Zhang, Kangning Su. ME 563: Nonlinear Finite Element Analysis.

Global Data Catalog initiative Christophe Charpentier ArcGIS Content Product Manager

Quick Guide QUICK GUIDE. Activity 1: Determine the Reaction Rate in the Presence or Absence of an Enzyme

[ Care and Use Manual ]

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

STTH61R04TV. Ultrafast recovery diode. Main product characteristics. Features and benefits. Order codes. Description A1 K2 ISOTOP ISOTOP STTH61R04TV1

L7800AB/AC SERIES PRECISION 1A REGULATORS

KD A LOW DROP POSITIVE VOLTAGE REGULATOR ADJUSTABLE AND FIXED

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541

Appendix B: Detailed tables showing overall figures by country and measure

CHARACTERIZATION OF VISCOELASTIC PROPERTIES OF POLYMERIC MATERIALS THROUGH NANOINDENTATION


IMPROVED METHOD TO DETERMINE THE HARDNESS AND ELASTIC MODULI USING NANO-INDENTATION

HCF4532B 8-BIT PRIORITY ENCODER

Cyclone Click to go to the page. Cyclone

of mass spectrometry

AN2970 Application note

2006 Supplemental Tax Information for JennisonDryden and Strategic Partners Funds

Obsolete Product(s) - Obsolete Product(s)

BSH Description. 2. Features. 3. Applications. 4. Pinning information. N-channel enhancement mode field-effect transistor

AN1755 APPLICATION NOTE

STTH60R04. Ultrafast recovery diode. Main product characteristics. Features and benefits. Description. Order codes

7.5A LOW DROP POSITIVE VOLTAGE REGULATOR ADJUSTABLE AND FIXED. October 2002

Augmented Reality Market Research Report- Global Forecast till 2023

protein interaction analysis bulletin 6300

Thermal correction - workpiece expansion. Thermal correction - workpiece expansion AP306. Problem

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

2N3904 SMALL SIGNAL NPN TRANSISTOR

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

TECHNICAL INFORMATION

L7800 SERIES POSITIVE VOLTAGE REGULATORS

74VHCT138ATTR 3 TO 8 LINE DECODER (INVERTING)

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 4, No 1, 2013

04 June Dim A W V Total. Total Laser Met

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

STTH6004W. Ultrafast high voltage rectifier. Table 1: Main product characteristics I F(AV) 60 A V RRM. 400 V T j (max) 175 C V F (typ)

LD29300xx. 3 A, very low drop voltage regulators. Features. Description


STTH6110TV. Ultrafast recovery - high voltage diode. Main product characteristics. Features and benefits. Order codes. Description ISOTOP ISOTOP

for XPS surface analysis

LD1117A SERIES LOW DROP FIXED AND ADJUSTABLE POSITIVE VOLTAGE REGULATORS

Order codes Part numbers DPAK (tape and reel) PPAK (tape and reel)

DO-15 DO-201AD STTH3R04Q STTH3R04

STTH16R04CT. Ultrafast recovery diode. Main product characteristics. Features and benefits. Description. Order codes TO-220AB TO-220FPAB

L7800 SERIES POSITIVE VOLTAGE REGULATORS

L79L00 SERIES NEGATIVE VOLTAGE REGULATORS

Nigerian Capital Importation QUARTER THREE 2016

Mat. Res. Soc. Symp. Proc. Vol Materials Research Society

Obsolete Product(s) - Obsolete Product(s)

EFFECT OF PILE-UP ON THE MECHANICAL CHARACTERISTICS OF STEEL WITH DIFFERENT STRAIN HISTORY BY DEPTH SENSING INDENTATION

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

A Prior Distribution of Bayesian Nonparametrics Incorporating Multiple Distances

Keysight Technologies In Situ Studies of a Fungal Polysaccharide Using MAC Mode AFM. Application Note

Canadian Imports of Honey

LD1117A SERIES LOW DROP FIXED AND ADJUSTABLE POSITIVE VOLTAGE REGULATORS

ORGANISATION FOR ECONOMIC CO-OPERATION AND DEVELOPMENT

Dielectric Analysis of Solid Insulations

Nanoindentation of Fibrous Composite Microstructures: Experimentation and Finite Element Investigation. Mark Hardiman

MECHANICAL PROPERTIES OF HYDROGEL USING NANOINDENTATION

NANOINDENTATION STUDIES OF PAPER

TECHNICAL INFORMATION

ST3L01 TRIPLE VOLTAGE REGULATOR

Obsolete Product(s) - Obsolete Product(s)

SDG s and the role of Earth Observation

IEEE Transactions on Image Processing EiC Report

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

Analysis of contact deformation between a coated flat plate and a sphere and its practical application

AN922 Application note

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

A Laboratory Experiment Using Nanoindentation to Demonstrate the Indentation Size Effect

Supplementary Figures

Transcription:

Keysight Technologies Measuring Substrate-Independent Young s Modulus of Low-k Films by Instrumented Indentation Application Note

Introduction In digital circuits, insulating dielectrics separate the conducting parts (wire interconnects and transistors) from one another. As components have scaled and transistors have gotten closer and closer together, the insulating dielectrics have thinned to the point where charge build-up and crosstalk adversely affect the performance of the device. It is this reduction in scale which drives the need for insulating materials with lower dielectric constant. A low-k material is one with a small value for dielectric constant relative to silicon dioxide (SiO 2 ) a former dielectric of choice. The dielectric constant of SiO 2 is 3.9. This number is the ratio of the permittivity of SiO 2 divided by permittivity of vacuum, SiO2 / O,where O = 8.854 x 10-6 pf/μm. There are many materials with lower dielectric constants, but few of them can be suitably integrated into a semiconductor manufacturing process [1]. At the extreme, dry air (20 C, 1 atm) has a dielectric constant of 1.00059 [2], but dry air cannot keep conducting materials mechanically separated, so it cannot be used as an insulator. But as one incorporates material for structure, the dielectric constant also increases. So the optimization problem in materials development for semiconductors is to lower the permittivity of the dielectric material as far as possible without compromising mechanical integrity, as quantified by the Young s modulus. Generally, processes purposed for reducing permittivity (such as pore introduction) also have the effect of reducing Young s modulus. Instrumented indentation is commonly employed in the semiconductor industry to measure the Young s modulus of low-k films deposited on silicon wafers. Two typical wafers are shown in Figure 1. Commonly, these films are less than 200 nm thick. Without any correction for influence of the underlying silicon substrate, one faces a compromise between uncertainty and error. At very small displacements, the error due to the substrate influence is small, but the uncertainty is greater due to surface roughness, tip variations, vibration, temperature variations, etc. As indentation depth increases, the uncertainty decreases, but the error due to substrate influence increases. The issue is even more complex because many low-k films present a skin with properties that are not representative of the bulk of the film. When testing such a film by instrumented indentation, the near-surface data are affected by this skin, and data at larger depths are affected by the substrate, leaving no domain in which the properties of the film alone can be obtained. Thus, the purpose of this work was to apply an analytic model to the analysis of low-k films tested by instrumented indentation in order to obtain the Young s modulus of the film alone. In a previous application note, such a model was introduced and verified by finite-element analysis [3]. Hereafter, this model will be called the Hay-Crawford model. Figure 1. Whole silicon wafers, coated with low-k materials.

03 Keysight Measuring Substrate-Independent Young s Modulus of Low-k Films by Instrumented Indentation - Application Note Theory The Hay-Crawford model provides an analytic means for accounting for substrate influence on measured modulus. The model presumes that apparent modulus has already been determined. Here, apparent modulus means modulus calculated according to the method of Oliver and Pharr [4]. This method has been explained in detail elsewhere [5, 6]. The Hay-Crawford model is expressed in terms of shear modulus; the general relation between Young s modulus (E), shear modulus (μ), and Poisson s ratio (υ) is E = 2μ(1+ υ). The Hay-Crawford model presumes that the film acts in series and in parallel with the substrate as illustrated in Figure 2. Thus, the apparent (substrate-affected) shear modulus (μ a ) is related to the shear modulus of the film (μ f ) and that of the substrate (μ s ) through this expression:. (Equation 1) Figure 2. Schematic of the proposed model. Top spring represents the action of the film. Bottom two springs represent the film and substrate acting in parallel. The weighting function, I 0, is due to Gao [7] ; it provides for a smooth transition between the influence of the film and that of the substrate. The expression for I 0 is provided in Figure 3 where it is plotted against normalized contact radius (a/t). Thus, the shear modulus of the film is calculated from the apparent value by solving Equation 1 for μ f :, where (Equation 2) A = 0.0626I 0 /μ a B = μ s /μ a + I 0 1 0.0626I 0 2 C = - I 0 /μ s Finally, the Young s modulus of the film is calculated from the shear modulus and Poisson s ratio as E f = 2μ f (1+ υ f ). (Equation 3) Figure 3. Weighting functions for shear modulus (I 0 ) and Poisson s ratio (I 1 ).

04 Keysight Measuring Substrate-Independent Young s Modulus of Low-k Films by Instrumented Indentation - Application Note Calculation of μ a from standard indentation results for use in Equation 1 requires a value for Poisson s ratio. The weighting function I 0 also utilizes Poisson s ratio. But what value should be used that of the film or that of the substrate? To be sure, this problem is of second order, but Gao also suggest a weighting function, I 1, for handling the transition in Poisson s ratio, so that the apparent Poisson s ratio, υ a, is calculated as. (Equation 4) Equation 4 provides the value for Poisson s ratio used in the calculation of μ a and I 0. It should be noted that if film and substrate have the same Poisson s ratio (that is, if υ s = υ f = υ), then Equation 4 reduces to υ a = υ. The expression for I 1 is also provided in Figure 3 where it is plotted against normalized contact radius. Experimental Method Samples Two low-k films on silicon were tested; the thickness of the first film was 1007 nm and the thickness of the second film was 445 nm. Figure 4 shows the two samples mounted for testing. In a previous application note, results were reported for these same samples, but without any accounting for substrate influence [8]. In this work, we compare results obtained by the Hay-Crawford model to those previously reported. Equipment and Procedure The two low-k samples were tested in a Keysight lab with a Keysight G200 NanoIndenter, utilizing the CSM option and a DCM II head fitted with a Berkovich indenter. Results were achieved using the NanoSuite test method G-Series DCM CSM for Thin Films. This test method implements the Hay-Crawford model to achieve substrate-independent measurements of Young s modulus. It should be noted that this method does not correct measurements of hardness for substrate influence. However, hardness measurements are generally less sensitive to substrate influence, because the extent of the plastic field is much smaller than the extent of the elastic field. Even when there is a substantial difference between film hardness and substrate hardness, the hardness measured at 10% of the film thickness usually manifests negligible substrate influence. Figure 4. Two low-k samples, as mounted for testing in the G200. Keysight NanoIndenters have been the industry choice for thin-film testing precisely because of the continuous stiffness measurement (CSM) option, which measures elastic contact stiffness (S) dynamically. With the CSM option, every indentation test returns complete depth profiles of Young s modulus and hardness. Using this option, eight tests were performed on each low-k sample. Loading was controlled such that the loading rate divided by the load (P /P) remained constant at 0.05/sec; loading was terminated at a penetration depth of 200 nm or greater. The excitation frequency was 75 Hz, and the excitation amplitude was controlled such that the displacement amplitude remained constant at 1 nm.

05 Keysight Measuring Substrate-Independent Young s Modulus of Low-k Films by Instrumented Indentation - Application Note Results and Discussion Results are summarized in Table 1. Figure 5 and Figure 6 show the Young s modulus as a function of penetration depth for each sample. The blue traces are the uncorrected values; these show what would be achieved without any correction for substrate influence using a standard NanoSuite test method such as G-Series DCM CSM Standard Hardness, Modulus, and Tip Cal. These blue traces show Young s modulus increasing as a function of displacement, because the silicon substrate, which is much stiffer, increasingly affects the measurement. The effect is more pronounced for thinner film; the blue traces increase most rapidly for the low-k 2 sample, because it is the thinnest film tested in this work. The red diamonds show the range used to calculate the (uncorrected) Young s moduli in the fifth column of Table 1. Logistically, these diamonds are placed by the user so as to select data which are, in the user s judgment, free from both surface anomalies and substrate influence. Table I. Summary of results. 1 2 3 4 5 6 7 8 9 Results, Standard Results, by Equations 1-3 Sample N Thickness Range* E a σ(e a ) Range** E f σ(e f ) nm nm GPa GPa nm GPa GPa low-k 1 8 1007 35-40 4.69 0.07 95.9-105.4 4.34 0.06 low-k 2 8 445 25-30 8.23 0.13 42.2-46.8 7.46 0.12 * Selected by eye ** Corresponds to 9.5-10.5% of film thickness The green traces of Figure 5 and Figure 6 are the values calculated according to Equations 1-3. The red diamonds show the range used to calculate the Young s moduli in the eighth column of Table 1, but diamonds were placed automatically by the software at 9.5% and 10.5% of the film thickness, respectively, so as to reduce the amount of user judgment involved in deriving results. The corrected Young s moduli cited at 10% of the film thickness (Table 1, column 8) are significantly lower than what was previously reported for these samples (Table 1, column 5). Another important observation is that when a correction for substrate influence is employed, the results can be taken from deeper into the film where surface anomalies have less influence. As a result, the standard deviations are smaller, as can be seen by comparing values in the sixth and ninth columns of Table 1. Figure 5. Low-k 1 on silicon substrate, t f = 1007 nm. Figure 6. Low-k 2 on silicon substrate, t f = 445 nm.

06 Keysight Measuring Substrate-Independent Young s Modulus of Low-k Films by Instrumented Indentation - Application Note Conclusions The Keysight G200 NanoIndenter with a DCM II head is the industry choice for these measurements because of its high-precision, speed, ease of use, and the CSM option, which delivers properties as a continuous function of penetration depth. In this work, NanoSuite Explorer was used to implement an analytic model which accounts for substrate influence. Test methods with this analysis are now available to customers with NanoSuite Professional. Having a model which corrects for substrate influence affords several practical advantages: Reported moduli are for the film alone, Less user influence, because depth range for calculating moduli does not have to be selected by eye, and Smaller uncertainty in results, because moduli are taken from deeper into the film. References 1. http://en.wikipedia.org/wiki/low-k#spin-on_organic_polymeric_dielectrics 2. http://hyperphysics.phy-astr.gsu.edu/hbase/tables/diel.html 3. J.L. Hay, A new model for measuring substrate-independent Young s modulus of thin films by instrumented indentation, Keysight Technologies application note (2014). 4. W.C. Oliver and G.M. Pharr, An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments, J. Mater. Res., 7(6): 1564 1583 (1992). 5. J.L. Hay, Introduction to instrumented indentation testing,experimental Techniques 33(6): 66-72 (2014). 6. J.L. Hay, P. Agee, and E.G. Herbert, Continuous stiffness measurement during instrumented indentation testing, Experimental Techniques 34(3):86-94 (2010). 7. H. Gao, C.-H. Chiu, and J. Lee, Elastic contact versus indentation modeling of multi-layered materials. Int. J. Solids Structures, 29: 2471-2492 (1992). 8. J.L. Hay, Young s modulus of dielectric low-k materials, Keysight Technologies application note (2014). Nano Mechanical Systems from Keysight Technologies Keysight Technologies, the premier measurement company, offers highprecision, modular nano-measurement solutions for research, industry, and education. Exceptional worldwide support is provided by experienced application scientists and technical service personnel. Keysight s leading-edge R&D laboratories ensure the continued, timely introduction and optimization of innovative, easy-to-use nanomechanical system technologies. www.keysight.com/find/nanoindenter For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-09-23-14) This information is subject to change without notice. Keysight Technologies, 2011-2015 Published in USA, March 11, 2015 5990-6508EN www.keysight.com