LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

Similar documents
Switches in conformity with ATEX directive

Universal limit switches

Non-Contact Safety Systems CMS

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2..

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

TeSys circuit-breakers

microswitches Low force

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

MINIATURE MICROSWITCHES - PREMIUM

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka

TeSys enclosed starters 2

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

ED 701 General Industry Pressure Transmitter

MINIATURE MICROSWITCHES - PREMIUM

SUBMINIATURE MICROSWITCHES - PREMIUM

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

Size A DIN EN

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

EX-EMERGENCY LIGHT FITTINGS

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics

X T O B P 1 6 B C 1 S

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

MR medium rating busbar

MCB NB1-63H Miniature Circuit Breaker

UL 1077 DIN Rail Supplementary Protectors

RoHS. Versatile. X g. X 2 e

CDS. high density spring connection

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

American Zettler AZ742 RELAY Datasheet

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Direct-operated 2/2-way solenoid valves Type EV210B

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

Surface-mounting Thermostats ATH Type Series

Linear measuring technology

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

VOLUMEC. Valve Position Indicator 5

General characteristics, Products

Installation guide 862 MIT / MIR

Imformation of C091D series

Capacitive Sensors. Contents

BETA Protecting Miniature Circuit Breakers

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

90 MCB range Modular circuit breakers for circuit protection

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Pushbutton Units and Indicator Lights

Field IT 50T Series Transmitters

H i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

Pressure Transmitter ED 701

5SP and 5SY Supplementary Protection UL 1077

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Film Capacitors. EMI suppression capacitors. Date: June 2018

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

DATA RACK BUSBAR. Data Rack Busbar Systems A.

Operating Instructions for Digital Manometer. Model: MAN-SD

General characteristics

TURQUOISE SWITCHES V TYPE (ABV)

PHOENIX CONTACT - 04/2016. Features

W 30 Photoelectric proximity switches: Clear signals even with low remission

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

8 Installation Equipment

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

E8EB-N0C2B E8EB-N0B2B

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

SIRCOVER Manual transfer switches from 125 to 3200 A

Test Report issued under the responsibility of: SHA-001 Date of issue... : Total number of pages... : 292. Report Number...

TeSys DF IEC-Type Fuseholders

TEST REPORT IEC/EN Circuit-breakers for over current protection for household and similar installations

Pressure transmitters for industrial applications MBS 32 and MBS 33

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

Surface-mounting thermostats Series ATH

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

LuxSpace recessed high efficiency, visual comfort and a stylish design

Impedance relay and protection assemblies

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Semiconductor (AC) fuses


Transcription:

TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks available Transverse head or longitudinal head versions M12 assembled connector versions D Series C Series Options & Ordering Codes Housing metal housing, one conduit entry metal housing, three conduit entries polymer housing, one conduit entry Contact Blocks,, 1NO+,,,,, Actuating Head longitudinal head P right transverse head (D & housing only) Note: The feasibility of a code number does not mean the effective availability of a product D C18 RRS J G X50 D left transverse head (D & housing only) C18 C9 C C21 C22 RRS RR RRR J J9 X0 4 pole M12 assembled plastic connector Threaded Conduit Entry PG 13.5 (standard) M x 1.5 Contact Type silver contacts (standard) G silver contacts gold plated 1 µm Actuating Force standard X21 X50 initial N...final N (only for head RRS) initial 13N...final 5N (only for heads RR & RRR) C RRS J G X22 H6 H6 Temperature standard - C to +80 C Preinstalled Cable Glands or Connectors no cable gland or connector (standard) with assembled cable gland suitable for Ø 6 to Ø 12mm cable ranges 5 pole M12 assembled metal connector Housing Preinstalled Cable Glands or Connectors metal housing, one conduit entry C no cable gland or connector (standard) Contact Blocks X22 with assembled cable gland suitable for Ø 5 to Ø 10mm cable ranges,, X26 with assembled cable gland suitable for Ø 3 to Ø mm cable ranges Actuating Head (as above) Actuating Force (as above) Threaded Conduit Entry PG 11 (standard) M x 1.5 p1 Contact Type (as above)

TECHNICA DATASHEET Specifications For safety applications up to: SI 3 acc. to EN 661 P e acc. to EN ISO 139 1 Safety parameters: B 10d : 2,000,000 for NC contacts Service life: years Ambient temperature: 25 C +80 C Max. actuation frequency: 1 cycle / 6 s Mechanical endurance: 1 million operating cycles 1 Max. actuation speed: 0.5 m/s Min. actuation speed: 1 mm/s In conformity with standards IEC 94-5-1, EN 94-5-1, EN 94-1, IEC 4-1, EN 4-1, EN ISO 14119, EN ISO 12100, IEC 529, EN 529, EN ISO 13850, EN 418, U 508, CSA 22.2 No.14. (1) One operation cycle means two movements, one to close and one to open contacts, as defined in EN 94 5 1. Housing P series housing made of glass fiber reinforced technopolymer, self-extinguishing, shock-proof and with double insulation: D, and C series: metal housing, baked powder coating. D, P, C series: one threaded conduit entry: PG13.5 (standard) series: three threaded conduit entries: Protection degree: PG13.5 (standard) IP6 acc. to EN 529 with cable gland of equal or higher protection degree In conformity with requirements requested by ow Voltage Directive 06/95/EC, Machinery Directive 06/42/EC and EMC Directive 04/122/EC. Positive contact opening in conformity with standards IEC 94 5 1, EN 94 5 1. Max cable cross section (flexible copper wire) Contact blocks C, C21, C22,, : min. 1 x 0.34 mm 2 (1 x AWG 22) max. 2 x 1.5 mm 2 (2 x AWG ) Contact blocks C18, C9: min. 1 x 0.5 mm 2 (1 x AWG ) max. 2 x 2.5 mm 2 (2 x AWG 14) Electrical data Utilization category without connector Thermal current (Ith): 10 A Rated insulation voltage (Ui): 500 Vac 0 Vdc 0 Vac 500 Vdc (contact blocks C, C21, C22,, ) Rated impulse withstand voltage (U imp ): 6 kv 4 kv (contact blocks C, C21, C22,, ) Conditional short circuit current: 1000 A acc. to EN 94 5 1 Protection against short circuits: type am fuse 10 A 500 V Pollution degree: 3 Alternating current: AC (50/ Hz) Ue (V) 250 0 500 Ie (A) 6 4 1 Direct current: DC13 Ue (V) 24 125 250 Ie (A) 6 1.1 0.4 with M12 connector 4 and 5 poles Thermal current (Ith): 4 A Rated insulation voltage (Ui): 250 Vac 0 Vdc Protection against short circuits: type gg fuse 4 A 500 V Pollution degree: 3 Alternating current: AC (50/ Hz) Ue (V) 24 1 250 Ie (A) 4 4 4 Direct current: DC13 Ue (V) 24 125 250 Ie (A) 4 1.1 0.4 with M12 connector 8 poles Thermal current (Ith): 2 A Rated insulation voltage (Ui): Vac 36 Vdc Protection against short circuits: type gg fuse 2 A 500 V Pollution degree: 3 Alternating current: AC (50/ Hz) Ue (V) 24 Ie (A) 2 Direct current: DC13 Ue (V) 24 Ie (A) 2 p2

TECHNICA DATASHEET Description These rope operated safety switches can be installed on machines or conveyor belts and are used to activate the emergency stop of the machine on intervention with the rope, at any point. They allow for cost savings on machines of medium-large size, where normally numerous emergency stop push buttons can be replaced by one single rope switch. Provided with a self-control function, when fitted properly they constantly check for correct operation, signalling with the opening of the contacts with a manual intervention (emergency stop activation) of an eventual pull, loosening or breaking of the rope. After activation the contacts remain open, until they are reset. Orientable heads aser engraving The markings of all devices are ASER printed on to the unit. As the markings are directly printed they are less likely to be rubbed off and do not fall off as found with some attached labels, making them suitable for extreme environments. Removing the four fastening screws makes it is possible to rotate the head in 90 steps. Protection degree IP6 These devices are designed to be used in the toughest environmental conditions and they pass the IP6 immersion test acc. to IEC 529. Indicator for the state of the reset Armed Reset Released Reset Reduced actuating force These switches can be supplied with a spring requiring less tension for movement hence reducing the effort needed to actuate the switch, while, maintaining the correct actuation of the electrical contacts. If the rope tensioning indicator is in the correct area, within the green band, the unit can be reset by pulling the blue button to close the safety contacts. The state of the switch can be quickly checked by observing the tension indicator s position with respect to the green band, and the blue button in the Released Reset/Armed Reset state. Adjustment point indicator of the rope All switches are provided with a green band, this green band area is for setting the correct tensioning of the rope. The installer has to tension the rope until the black indicator is set to the middle of this green band. Extended temperature range This switch range is also available in a special version with an ambient operating temperature range of - C to +80 C for low temperature environments such as cold stores and sterilisers. When set, a pull or loosing of the rope allows the black indictor to travel to the outside of the correct tension area (green band), at this point the safety contacts are opened and the reset device is triggered. Adjustment of the operating point Tension indicator Area of correct rope tightening Tighten the rope connected to the switch, until the end of the indicator (1) reaches about the middle of the green ring (2). Pull the knob (3) in order to close the safety contacts inside the switch. A green band (4) will be exposed to indicate the Armed reset condition. p3

TECHNICA DATASHEET Selection diagram RRS RRS RR RRR ACTUATORS ACTUATORS CONTACT BOCKS C18 C9 C C21 1NO+,, P D C C22,, CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland With M12 plastic connector With M12 metal connector Product option p4

Dimensional drawings All measures in the drawings are in mm Contact type: =.8-34.3.8-34.3 65 28 28. -.2 65 28 28. -.2 C18 C9 C C21 C22.8-34.3.8-34.3 65 28 28. -.2 6.5 6.5 5 6.5 18 18 18 5 5 5.4.2 Contact blocks 5.9 5.4x.4.2.4 38.6 6.2 x.3.4 36.5 6.2 x.3.4 36.5 6.2 x.3.4 36.5 PC18RRS DC18RRS DC18RR DC18RRR PC9RRS DC9RRS DC9RR DC9RRR PCRRS 1NO+ DCRRS 1NO+ DCRR 1NO+ DCRRR 1NO+ PC21RRS DC21RRS DC21RR DC21RRR PC22RRS DC22RRS DC22RR DC22RRR PRRS DRRS DRR DRRR PRRS DRRS DRR DRRR Min. force Travel diagrams Initial 63 N...final 83 N (90 N ) group 1 Initial 63 N...final 83 N (90 N ) group 1 Initial 14 N final 235 N (250 N ) Initial 14 N final 235 N (250 N ) Contact blocks 56 31.5 56 31.5 56 31.5 C18 C18RRS C18RR C18RRR C9 C9RRS C9RR C9RRR C CRRS 1NO+ CRR 1NO+ CRRR 1NO+ C21 C21RRS C21RR C21RRR C22 C22RRS C22RR C22RRR RRS RR RRR RRS RR RRR Min. force Travel diagrams Initial 63 N...final 83 N (90 N ) group 1 Initial 14 N final 235 N (250 N ) Initial 14 N final 235 N (250 N ) p5

Contact type: = 65 28 28. -.2.8-34.3.8-34.3 45.5 45.5 45.5 Contact blocks Min. force Travel diagrams 33.4 CRRS CRRS Initial 63 N...final 83 N (90 N ) group 1 33.4 CRR CRR Initial 14 N final 235 N (250 N ) 33.4 CRRR CRRR Initial 14 N final 235 N (250 N ) How to read travel diagrams All measures in the diagrams are in mm NC opening NO closing Reset intervention Ideal rope tension point Max. travel 0 4 23-24 diagram Closed contact 8 11-12 Open contact Cut of the rope Traction of the rope NC opening NO closing Reset intervention Positive opening travel Travel diagrams table Contact blocks C18 C9 C 1NO+ C21 C22 1NC+1NO Group 1 Group 2 0 4 0 8 14 8 0 4 14 0 8 8 0 4 8 0 8 14 0 4 8 0 8 14 0 4 8 0 14 8 0 4 8 0 8 14 0 4 0 8 14 8 IMPORTANT: In safety applications, actuate the switch at least up to the positive opening travel shown in the travel diagrams with symbol. Operate the switch at least with the positive opening force, indicated between brackets below each article, aside the minimum force value. p6

Application examples and max. rope length for switches with longitudinal head (showing IMO accessories part numbers) A DC18RRS DC18RRS 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m 24 m MAX AC-ME8 B DC18RRS 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m 18 m MAX E AC-F05 C DC18RRS AC-CA10 2 3 m 2 3 m 2 3 m 12 m MAX D DC18RRS AC-F05 DC18RRS AC-TR8 6 m MAX 3 m max 3 m max Application examples and max. rope length for switches with transversal head (showing IMO accessories part numbers) F G H DC18RRR DC18RRR DC18RRR 3 5 m 3 5 m 3 5 m 3 5 m 3 5 m 3 5 m 3 5 m 0 m MAX 3 5 m 3 5 m 3 5 m 3 5 m 3 5 m 3 5 m 35 m MAX 50 m MAX 3 5 m 3 5 m 3 5 m AC-ME80 AC-CA10 DC18RR J AC-F05 AC-F05 FD DC18RR 1880-M2 AC-TR8 I DC18RRR m MAX 35 m max 35 m max p8

Max. rope length Max. rope length (m) 25 10 Max. rope length for switches with longitudinal head example A example B example C-E example D In the diagram, the suggested max. rope lengths with regard to changes of temperature (thermal differential) to which the switch is expected to be exposed in the working area are indicated. For instance, for an installation acc. to example C which expects a thermal differential of C, a max. rope length of 10 meters is suggested. 5 0 0 10 50 0 80 90 100 80 0 Thermal differential ( C) Max. rope length for switches with transverse head example F example G example H-J example I Max. rope length (m) 50 10 0 0 10 50 0 80 90 100 Thermal differential ( C) Important: The above data are guaranteed only using original rope and accessories. p8