Certificate No.: IECEx BVS issue No. 1 Annex Page 1 of 8 Subject and Type

Similar documents
Certificate No.: IECEx BVS , issue 3 Annex Page 1 of 9

TÜV NORD CERT GmbH Hanover Office Am TÜV Hanover Germany. Testing Laboratory Explosion Protected Equipment and Monitoring Devices

ANNEX to IECEx Certificate


Page 1 of 16 Issue No. 0 of IECEx TUN X

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

ATEX/IECEx RTD temperature probe

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

I Ex d/e Switch- and Control-Equipment I

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

Reflex-Radar BM 100 A

Pressure Measurement Single-range transmitters for general applications

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

Physikalisch-Technische Bundesanstalt

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

SmartLine Radar Level Meter RM70

ED 701 General Industry Pressure Transmitter

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

PRODUCT CATALOGUE PREssURE switch

Installation guide 862 MIT / MIR

EX-EMERGENCY LIGHT FITTINGS

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

Installation Equipment

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Switches in conformity with ATEX directive

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Electromagnetic Flowmeter

Field mounted Temperature Transmitter TF212/TF212-Ex

Exchangeable measuring insets SensyTemp TSA101

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

Full Metal Variable Area Flow Meter and Counter

Z7A. Load cells. Special features. Data sheet. Wiring code

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

PHOENIX CONTACT - 04/2016. Features

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Single point load cells

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Industrial Resistance Thermometers according to DIN Model MWD

Pressure transmitters for industrial applications MBS 32 and MBS 33

8 Installation Equipment

EX-CONTROL AND DISTRIBUTION SYSTEMS

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

Ex floating switches and Ex immersion probes

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

DATA RACK BUSBAR. Data Rack Busbar Systems A.

Safety Barriers Series 9001, 9002 Standard Applications

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

SANMUR CONTROLS PVT. LTD.

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

TH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation

CEAG Products Main Catalogue Part 1 Chapter 2. Ex-Light fittings. EATON 1.2.1

Temperature sensors SensyTemp TSP311, TSP321, TSP331

CEAG Products Main Catalogue Part 1 Chapter 4. Ex-Ceiling, pendant light fittings and floodlights. EATON 1.4.1

Field IT 50T Series Transmitters

AT9000 Advanced Transmitter Differential Pressure Transmitters

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

PROline promag 53 Division 1

1 Overview. Pressure Measurement Transmitters for applications with basic requirements (Basic) SITRANS P310 - Technical description

tekcor TKC Multivariable Coriolis Flow Sensors

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

Universal limit switches

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Analogue Meters CQ2x07 series

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

System Components. Electric Motors.

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

Model DS1200-AMT-Ex Intrinsically Safe 4-20mA ATEX Certified Dewpoint Hygrometer Ranges available between -120 C to +20 C (-166 F to +68 F) dewpoint

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Linear Motors with ATEX and IECEx Certification

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

E X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S

Pressure Transmitter ED 701

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

VersaFlow TWM 9000 Electromagnetic Flow Converter Technical Datasheet. Specification. Highlights. Electromagnetic product range.

DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER

ISEmax CAM40/CAS40. Technical Information

Type Function Output config. Auxiliary Case Page

Ultrasonic Gas Flow Meter

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

Transcription:

Certificate No.: IECEx BVS 12.0066 issue No. 1 Page 1 of 8 Subject and Type VEGAFLEX FX81(*). I * * ** * * * * * * * Certificates: X = no, M - yes adjustment / indication module PLICSCOM X = without: A = with cable entry: M = M20 x 1.5; N = 1/2" NPT enclosure A = aluminium enclosure IP66 H = special colour aluminium enclosure IP66 D = aluminium double chamber enclosure IP66 S = special colour aluminium double chamber enclosure IP66 V = stainless steel enclosure IP66 W = stainless steel double chamber enclosure IP66 additional electronics X = without, Z = additional output 2 wire 4 20 ma electronics P = Profibus PA F = Foundation Fieldbus H = 2 wire 4 20 ma HART A = 2 wire 4 20 ma HART with SIL B = 4 wire 4 20 ma HART, AC 90 253 VAC; 50/60 Hz I = 4 wire 4 20 ma HART, DC 9.6 48 VAC; AC 20 42 V U = Modbus sealing/second line of defense/process temperature G = FKM (SHS FPM 70C3 GLT)/with/ -40...+150 C P = FFMK (Kalrez 6375)/with/ -20...+150 C L = FFMK (Kalrez 6375)/ with/ -20...+200 C M = EPDM (A+P 75.5/KW75F)/with/ -40...+150 C N = Silicon FEP coated/with/ -40...+ 150 C A = FKM (SHS FPM 70C3 GLT)/without/ -40...+150 C F = FFMK (Kalrez 6375)/without/ -20...+150 C D = FFMK (Kalrez 6375)/without/ -20...+200 C process connection see manual version / material B = exchangeable rope 2 mm with gravity weight/316 D = exchangeable rope 2 mm with centr. gravity weight/316 A = exchangeable rope 4 mm with gravity weight/316 C = exchangeable rope 4 mm with centr. gravity weight/316 E = exchangeable rod 8 mm / 316 L F = exchangeable rod 12 mm / 316 L K = coax version 21.3 mm with single hole / 316 L L = coax version 21.3 mm with multiple hole / 316 L M = coax version 21.3 mm for Ammonia / 316 L N = coax version 42.2 mm with multiple hole / 316 L U = exchangeable rope 4 mm without centr.gravity weight/316l X,Y,Z = basic versions / 316 L certificate R = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db H = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex ia IIC T6, Ga, Ga/Gb (IECEx TUN12.0009X, IECEx TUN13.0029X, IECEx TUN13.0016X) J = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d IIC T6 Ga/Gb (IECEx TUN12.0011X, IECEx TUN13.0032X) I = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d ia IIC T6 Ga/Gb (IECEx TUN12.0019X) optional version differentiation, without relevance for explosion protection

Certificate No.: IECEx BVS 12.0066 issue No. 1 Page 2 of 8 VEGAFLEX FX82(*). I * * ** * * * * * * * certificates X = no, M - yes adjustment / indication module PLICSCOM X = without; A = with cable entry M = M20 x 1.5; N = 1/2" NPT enclosure A = aluminium enclosure IP66 H = special colour aluminium enclosure IP66 D = aluminium double chamber enclosure IP66 S = special colour aluminium double chamber enclosure IP66 V = stainless steel enclosure IP66 W = stainless steel double chamber enclosure IP66 additional electronics X = without Z = additional output 2 wire 4 20 ma electronics P = Profibus PA F = Foundation Fieldbus H = 2 wire 4 20 ma HART A = 2 wire 4 20 ma HART with SIL B = 4 wire 4 20 ma HART, AC 90 253 VAC; 50/60 Hz I = 4 wire 4 20 ma HART, DC 9,6 48 VAC; AC 20 42 V U = Modbus sealing/process temperature A = FKM (SHS FPM 70C3 GLT)/ -40...+80 C F = FKM (SHS FPM 70C3 GLT)/ -40...+150 C B = EPDM /A+P 75.5/KW75F)/ -40...+80 C H = EPDM /A+P 75.5/KW75F)/ -40...+150 C K = FFMK (Kalrez 6375)/ -20...+200 C process connection see manual version / material A = exchangeable rope 4 mm with gravity weight / 316 E = exchangeable rope 6 mm, PA coated, with gravity weight / 316 F = exchangeable rope 6 mm with gravity weight / 316 G = exchangeable rope 11 mm, PA coated, with gravity weight / 316 H = changeable rod 16 mm / 316 L certificate R = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db H = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex ia IIC T6, Ga, Ga/Gb (IECEx TUN12.0009X, IECEx TUN13.0029X, IECEx TUN13.0016X) J = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d IIC T6 Ga/Gb (IECEx TUN12.0011X, IECEx TUN13.0032X) I = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d ia IIC T6 Ga/Gb (IECEx TUN12.0019X) optional version differentiation, without relevance for explosion protection

Certificate No.: IECEx BVS 12.0066 issue No. 1 Page 3 of 8 VEGAFLEX FX83(*). I * * ** * * * * * * * certificates X = no, M - yes adjustment / indication module PLICSCOM X = without; A = with cable entry M = M20x1.5; N = 1/2" NPT enclosure A = aluminium enclosure IP66 H = special colour aluminium enclosure IP66 D = aluminium double chamber enclosure IP66 S = special colour aluminium double chamber enclosure IP66 V = stainless steel enclosure IP66 W = stainless steel double chamber enclosure IP66 additional electronics X = without Z = additional output 2 wire 4 20 ma electronics P = Profibus PA F = Foundation Fieldbus H = 2 wire 4 20 ma HART A = 2 wire 4 20 ma HART with SIL B = 4 wire 4 20 ma HART, AC 90 253 VAC; 50 / 60 Hz I = 4 wire 4 20 ma HART, DC 9.6 48 VAC; AC 20 42 V U = Modbus sealing/process temperature X = without/ -40...+150 C C = EPDM (Freudenberg 70 EPDM 291)/ -20...+130 C E = FFMK (Kalrez 6221)/ -20...+150 C process connection see manual version / material B = rope 4 mm with gravity weight / PFA E = rod 10 mm/pfa F = exchangeable rod 8 mm / 14435 (Basler) G = exchangeable rod 8 mm / 14435 (Basler), autoclaved X = basic version rod 8 mm / 14435 (Basler) R = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db H = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex ia IIC T6, Ga, Ga/Gb (IECEx TUN12.0009X, IECEx TUN13.0029X, IECEx TUN13.0016X) I = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d ia IIC T6 Ga/Gb (IECEx TUN12.0019X) optional version differentiation, without relevance for explosion protection

Certificate No.: IECEx BVS 12.0066 issue No. 1 Page 4 of 8 VEGAFLEX FX86(*). I * * ** * * * * * * * certificates X = no, M - yes adjustment / indication module PLICSCOM X = without; A = with cable entry M = M20 x 1.5; N = 1/2" NPT enclosure A = aluminium enclosure IP66 H = special colour aluminium enclosure IP66 D = aluminium double chamber enclosure IP66 S = special colour aluminium double chamber enclosure IP66 V = stainless steel enclosure IP66 W = stainless steel double chamber enclosure IP66 additional electronics X = without Z = additional output 2 wire 4 20 ma electronics P = Profibus PA F = Foundation Fieldbus H = 2 wire 4 20 ma HART A = 2 wire 4 20 ma HART with SIL B = 4 wire 4 20 ma HART, AC 90 253 VAC; 50 / 60 Hz I = 4 wire 4 20 ma HART, DC 9.6 48 VAC; AC 20 42 V U = Modbus sealing/second line of defense/process temperature 1 = Keramik-Grafit/with/ -196...+280 C 2 = Keramik-Grafit/with/ -196...+450 C (400 C) 3 = PEEK-FFKM (Kalrez 6375) 20 C 250 C process connection see manual version / material B = changeable rope 2 mm with gravity weight / 316 D = changeable rope 2 mm with centr. weight / 316 H = changeable rod 16 mm / 316 L X = basic version / 316 L A = changeable rope 4 mm with gravity weight / 316 C = changeable rope 2 mm with centr. weight / 316 P = coax version 42.2 mm with multiple hole / 316 L certificate R = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db H = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex ia IIC T6, Ga, Ga/Gb (IECEx TUN12.0009X, IECEx TUN13.0029X, IECEx TUN13.0016X) J = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d IIC T6 Ga/Gb (IECEx TUN12.0011X, IECEx TUN13.0032X) I = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d ia IIC T6 Ga/Gb (IECEx TUN12.0019X) optional version differentiation, without relevance for explosion protection Parameters

Certificate No.: IECEx BVS 12.0066 issue No. 1 Page 5 of 8 Electrical data Supply circuits Types VEGAFLEX FX8*(*).IR********** Type VEGAFLEX FX8*(*).IR****H/A***** Supply and signal circuit U = 9.6 V 30 V DC (terminals Kl1/1, Kl1/2 in the electronics U m = 30 V DC compartment or in the terminal compartment regarding the two chamber enclosure version) Type VEGAFLEX FX8*(*).IR****H/AZ**** Supply and signal circuit I U = 9.6 V 30 V DC (terminals Kl1/1, Kl1/2 in the terminal U m = 30 V DC compartment of the two chamber enclosure version) Supply and signal circuit II U = 9.6 V 30 V DC (terminals Kl2/7, Kl2/8 in the terminal U m = 30 V DC compartment of the two chamber enclosure version) Type VEGAFLEX FX8*(*).IR****P/F***** Supply and signal circuit U = 9.6 V 32 V DC (terminals Kl1/1, Kl1/2 in the electronics U m = 32 V DC compartment or in the terminal compartment regarding the two chamber enclosure version) Types VEGAFLEX FX8*(*).II****H/A***** Supply and signal circuit (terminals Kl1/1, U = 14 V 35 V DC Kl1/2 in the terminal compartment) U m = 253 V AC TypesVEGAFLEX FX8*(*).IJ*********** Type VEGAFLEX FX8*(*).IJ****H/A***** Supply and signal circuit U = 9.6 V 35 V DC (terminals Kl1/1, Kl1/2) U m = 35 V DC Type VEGAFLEX FX8*(*).IJ****P/F***** Supply and signal circuit U = 9 V 32 V DC (terminals Kl1/1, Kl1/2) U m = 253 V AC Types VEGAFLEX FX8*(*).IR/I****U***** Supply and signal circuit U = 8 V 30 V DC (terminals Kl1/1, Kl1/2) U m = 253 V AC Supply and signal circuit U max = 5 V DC (terminals MB(+), MB(-)) MODBUS-Signal (telegramme) U m = 30 V DC USB U max = 5 V DC (6 pin mini USB bush) USB-signal (USB-protocol) U m = 30 V DC Types VEGAFLEX FX8*(*).IR/I****B***** Supply and signal circuit U = 90 V 253 V DC (terminals Kl1/1, Kl1/2) U m = 253 V AC

Certificate No.: IECEx BVS 12.0066 issue No. 1 Page 6 of 8 active 4-20 ma signal circuit I out = 4-20 ma with superposed HART-signal (terminals K15(+),K17(-) U m = 60 V AC/DC passive 4-20 ma signal circuit I in = 4-20 ma with superposed HART-signal (terminals K16(+), K17(-)) U m = 60 V AC/DC Types VEGAFLEX FX8*(*).IR/I****I***** Supply and signal circuit U = 9.6 V 48 V DC / 42 V AC (terminals Kl1/1, Kl1/2) U m = 253 V AC active 4-20 ma signal circuit I out = 4-20 ma with superposed HART-signal (terminals K15(+),K17(-) U m = 60 V AC/DC passive 4-20 ma signal circuit I in = 4-20 ma with superposed HART-signal (terminals K16(+), K17(-)) U m = 60 V AC/DC Types VEGAFLEX FX8*(*).IH*********** Type VEGAFLEX FX8*(*).IH****H/A***** Supply and signal circuit (terminals Kl1/1, Kl1/2) in the electronics compartment or in the terminal compartment regarding the two chamber enclosure version) maximum values: U i = 30 V I i = 131 ma P i = 983 mw effective internal inductance L i = 5 H, in the two chamber enclosure version L i = 10 μh effective internal capacitance negligible Type VEGAFLEX FX8*(*).IH****H/AZ**** Supply and signal circuit I (terminals Kl1/1and Kl1/2 in the terminal compartment of the two chamber enclosure version) in type of protection Intrinsic Safety Ex ia IIC for connection to a certified intrinsically safe circuit in type of protection Intrinsic Safety Ex ia IIC for connection to a certified intrinsically safe circuit maximum values: U i = 30 V I i = 131 ma P i = 983 mw effective internal inductance L i = 5 H effective internal capacitance negligible Supply and signal circuit II (terminals Kl2/7and Kl2/8 in the terminal compartment of the two chamber enclosure in type of protection Intrinsic Safety Ex ia IIC for connection to a certified intrinsically safe circuit maximum values U i = 30 V I i = 131 ma P i = 983 mw effective internal inductance L i = 5 H effective internal capacitance negligible Type VEGAFLEX FX8*(*).IH****P/F***** Supply and signal circuit (terminals K1[+]and K2[-] in the electronics compartment or in the terminal compartment in type of protection Intrinsic Safety Ex ia IIC for connection to a certified intrinsically safe circuit

Certificate No.: IECEx BVS 12.0066 issue No. 1 Page 7 of 8 regarding the two chamber enclosure version) maximum values The equipment is suitable for connection to a Fieldbus-system according to FISCO-Model (IEC 60079-11) e.g. PROFIBUS-PA or in the version with fixed cable: U i = 17.5 V I i = 500 ma P i = 5.5 W U i = 24 V I i = 250 ma P i = 1.2 W C i negligible negligible L i C i wire/wire = 58 pf/m and C i wire/screen = 270 pf/m L i = 0.55 5 H/m have to be regarded Intrinsic safe signal circuits, electronics compartment Types VEGAFLEX FX8*(*).IR/H****H/A/P/F*****, VEGAFLEX FX8*(*).IR/H****H/AZ****, VEGAFLEX FX8*(*).II****H/A***** adjustment and indication circuit in type of protection Intrinsic Safety Ex ia IIC (terminals 5, 6, 7, 8) for connection to the intrinsically safe signal circuit of the associated VEGA adjustment and indication unit VEGADIS61 or VEGADIS81 L cable 212 H C cable 1.98 F Types VEGAFLEX FX8*(*).IR/H****H/A/P/F*****, VEGAFLEX FX8*(*).IR/H****H/AZ****, VEGAFLEX FX8*(*).IR/I****B/I/U*****, VEGAFLEX FX8*(*).II****H/A***** adjustment and indication circuit in type of protection Intrinsic Safety Ex ia IIC (spring contact) for connection to the VEGA adjustment and indication unit PLICSCOM or to the interface adapter VEGACONNECT Non- intrinsic safe signal circuits, electronics compartment Types VEGAFLEX FX8*(*).IR****H/A/PF*****, VEGAFLEX FX8*(*).IR****H/AZ***** adjustment and indication circuit For connection to the signal circuit of the associated (terminals 5, 6, 7, 8) VEGA adjustment and indication unit VEGADIS81, type VEGADIS DIS81.RX** Thermal parameter Permitted temperature range At the sensor (zone 20 or 21) Type VEGAFLEX FX81

Certificate No.: IECEx BVS 12.0066 issue No. 1 Page 8 of 8 VEGAFLEX FX81(*).I****AA/H/B/I/U/P/F***** -40 C. +80 C VEGAFLEX FX81(*).I****AA/HZ**** -40 C. +80 C VEGAFLEX FX81(*).I****D/F/PA/H/B/I/U/P/F***** -20 C.+150 C VEGAFLEX FX81(*).I****D/F/PA/HZ**** -20 C.+150 C VEGAFLEX FX81(*).I****LA/H/B/I/U/P/F***** -20 C.+200 C VEGAFLEX FX81(*).I****LA/HZ**** -20 C.+200 C Type VEGAFLEX FX82 VEGAFLEX FX82(*).I****A/BA/H/B/I/U/P/F***** -40 C. +80 C VEGAFLEX FX82(*).I****A/BA/HZ**** -40 C. +80 C VEGAFLEX FX82(*).I****F/HA/HZ**** -40 C.+150 C VEGAFLEX FX82(*).I****F/HA/H/B/I/U/P/F***** -40 C.+150 C VEGAFLEX FX82(*).I****KA/H/B/I/U/P/F***** -20 C.+200 C VEGAFLEX FX82(*).I****KA/HZ**** -20 C.+200 C Type VEGAFLEX FX83 VEGAFLEX FX83(*).I****XA/H/B/I/U/P/F***** -40 C.+150 C VEGAFLEX FX83(*).I****XA/HZ**** -40 C.+150 C VEGAFLEX FX83(*).I****CA/H/B/I/U/P/F***** -20 C.+130 C VEGAFLEX FX83(*).I**** CA/HZ**** -20 C.+130 C VEGAFLEX FX83(*).I****EA/H/B/I/U/P/F***** -20 C.+150 C VEGAFLEX FX83(*).I****EA/HZ**** -20 C.+150 C Type VEGAFLEX FX86 VEGAFLEX FX86(*).I****1A/H/B/I/U/P/F***** -196 C.+280 C VEGAFLEX FX86(*).I****1A/HZ**** -196 C.+280 C VEGAFLEX FX86(*).I****2A/H/B/I/U/P/F***** -196 C.+450 C (400 C) VEGAFLEX FX86(*).I**** 2A/HZ**** -196 C.+450 C (400 C) VEGAFLEX FX86(*).I****3A/H/B/I/U/P/F***** -20 C.+250 C VEGAFLEX FX86(*).I****3A/HZ**** -20 C.+250 C At the electronics enclosure (Zone 20 or 21) -40 C. +60 C Maximum surface temperature At the sensor (zone 20 or 21) VEGAFLEX FX8*(*).I*****A/H/B/I/U/P/F***** VEGAFLEX FX8*(*).I****U****** process temperature + 2 K process temperature + 10 K At the electronics enclosure (Zone 20 or 21) VEGAFLEX FX8*(*).IR/I***B/I****** with temperature fuse limited to 102 C VEGAFLEX FX8*(*).IR/I***U****** ambient temperature + 60 K VEGAFLEX FX8*(*).IR/I***A/H****** ambient temperature + 12 K VEGAFLEX FX8*(*).IH***A/H/P/F****** ambient temperature + 12 K VEGAFLEX FX8*(*).IJ***A/H/P/F****** ambient temperature + 29 K VEGAFLEX FX8*(*).IR/H***A/HZ***** ambient temperature + 24 K Degrees of protection according to IEC 60529 IP 66

Certificate No.: IECEx BVS 12.0066 Page 1 of 7 General product information: Subject and Type VEGAFLEX FX81(*). I * * ** * * * * * * * certificates X = no, M - yes adjustment / indication module PLICSCOM X = without; A = with cable entry M = M20x1.5; N = 1/2" NPT enclosure A = aluminium enclosure IP66 D = aluminium double chamber enclosure IP66 V = stainless steel enclosure IP66 W = stainless steel double chamber enclosure IP66 additional electronics X = without Z = additional output 2 wire 4 20 ma electronics H = 2 wire 4 20 ma HART A = 2 wire 4 20 ma HART with SIL B = 4 wire 4 20 ma HART, AC 90 253 VAC; 50/60 Hz I = 4 wire 4 20 ma HART, DC 9.6 48 VAC; AC 20 42 V U = Modbus sealing/second line of defense/process temperature G = FKM (SHS FPM 70C3 GLT)/with/ -40...+150 C P = FFMK (Kalrez 6375)/with/ -20...+150 C L = FFMK (Kalrez 6375)/ with/ -20...+200 C M = EPDM (A+P 75.5/KW75F)/with/ -40...+150 C N = Silicon FEP coated/with/ -40...+ 150 C A = FKM (SHS FPM 70C3 GLT)/without/ -40...+150 C F = FFMK (Kalrez 6375)/without/ -20...+150 C D = FFMK (Kalrez 6375)/without/ -20...+200 C process connection see manual version / material B = exchangeable rope 2 mm with gravity weight / 316 D = exchangeable rope 2 mm with centr. gravity weight / 316 A = exchangeable rope 4 mm with gravity weight / 316 C = exchangeable rope 4 mm with centr. gravity weight / 316 E = exchangeable rod 8 mm / 316 L F = exchangeable rod 12 mm / 316 L K = coax version 21.3 mm with single hole / 316 L L = coax version 21.3 mm with multiple hole / 316 L M = coax version 21.3 mm for Ammonia / 316 L P = coax version 42.2 mm with multiple hole / 316 L X,Y,Z = basic versions / 316 L certificate R = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db H = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex ia IIC T6, Ga, Ga/Gb (IECEx TUN 12.0009X) J = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d IIC T6, Ga/Gb (IECEx TUN 12.0011X) I = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d ia IIC T6, Ga/Gb (IECEx TUN 12.0019X) optional version differentiation, without relevance for explosion protection

Certificate No.: IECEx BVS 12.0066 Page 2 of 7 VEGAFLEX FX82(*). I * * ** * * * * * * * certificates X = no, M - yes adjustment / indication module PLICSCOM X = without; A = with cable entry M = M20x1.5; N = 1/2" NPT enclosure A = aluminium enclosure IP66 D = aluminium double chamber enclosure IP66 V = stainless steel enclosure IP66 W = stainless steel double chamber enclosure IP66 additional electronics X = without Z = additional output 2 wire 4 20 ma electronics H = 2 wire 4 20 ma HART A = 2 wire 4 20 ma HART with SIL B = 4 wire 4 20 ma HART, AC 90 253 VAC; 50/60 Hz I = 4 wire 4 20 ma HART, DC 9,6 48 VAC; AC 20 42 V U = Modbus sealing/process temperature A = FKM (SHS FPM 70C3 GLT)/ -40...+80 C F = FKM (SHS FPM 70C3 GLT)/ -40...+150 C B = EPDM /A+P 75.5/KW75F)/ -40...+80 C H = EPDM /A+P 75.5/KW75F)/ -40...+150 C K = FFMK (Kalrez 6375)/ -20...+200 C process connection see manual version / material A = exchangeable rope 4 mm with gravity weight / 316 E = exchangeable rope 6 mm, PA coated, with gravity weight / 316 F = exchangeable rope 6 mm with gravity weight / 316 G = exchangeable rope 11 mm, PA coated, with gravity weight / 316 H = changeable rod 16 mm / 316 L certificate R = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db H = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex ia IIC T6, Ga, Ga/Gb (IECEx TUN 12.0009X) J = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d IIC T6, Ga/Gb (IECEx TUN 12.0011X) I = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d ia IIC T6, Ga/Gb (IECEx TUN 12.0019X) optional version differentiation, without relevance for explosion protection

Certificate No.: IECEx BVS 12.0066 Page 3 of 7 VEGAFLEX FX83(*). I * * ** * * * * * * * certificates X = no, M - yes adjustment / indication module PLICSCOM X = without; A = with cable entry M = M20x1.5; N = 1/2" NPT enclosure A = aluminium enclosure IP66 D = aluminium double chamber enclosure IP66 V = stainless steel enclosure IP66 W = stainless steel double chamber enclosure IP66 additional electronics X = without Z = additional output 2 wire 4 20 ma electronics H = 2 wire 4 20 ma HART A = 2 wire 4 20 ma HART with SIL B = 4 wire 4 20 ma HART, AC 90 253 VAC; 50 / 60 Hz I = 4 wire 4 20 ma HART, DC 9.6 48 VAC; AC 20 42 V U = Modbus sealing/process temperature X = without/ -40...+150 C C = EPDM (Freudenberg 70 EPDM 291)/ -20...+130 C E = FFMK (Kalrez 6221)/ -20...+150 C process connection see manual version / material B = rope 4 mm with gravity weight / PFA E = rod 6 mm/pfa F = exchangeable rod 8 mm / 14435 (Basle) G = exchangeable rod 8 mm / 14435 (Basle), autoclaved X = basic version rod 8 mm / 14435 (Basler) certificate R = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db H = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex ia IIC T6, Ga, Ga/Gb (IECEx TUN 12.0009X) J = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d IIC T6, Ga/Gb (IECEx TUN 12.0011X) I = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d ia IIC T6, Ga/Gb (IECEx TUN 12.0019X) optional version differentiation, without relevance for explosion protection

Certificate No.: IECEx BVS 12.0066 Page 4 of 7 VEGAFLEX FX86(*). I * * ** * * * * * * * certificates X = no, M - yes adjustment / indication module PLICSCOM X = without; A = with cable entry M = M20x1.5; N = 1/2" NPT enclosure A = aluminium enclosure IP66 D = aluminium double chamber enclosure IP66 V = stainless steel enclosure IP66 W = stainless steel double chamber enclosure IP66 additional electronics X = without Z = additional output 2 wire 4 20 ma electronics H = 2 wire 4 20 ma HART A = 2 wire 4 20 ma HART with SIL B = 4 wire 4 20 ma HART, AC 90 253 VAC; 50 / 60 Hz I = 4 wire 4 20 ma HART, DC 9.6 48 VAC; AC 20 42 V U = Modbus sealing/second line of defense/process temperature 1 = Keramik-Grafit/with/ -196...+280 C 2 = Keramik-Grafit/with/ -196...+450 C (400 C) process connection see manual version / material B = changeable rope 2 mm with gravity weight / 316 D = changeable rope 2 mm with centr. weight / 316 H = changeable rod 162 mm / 316 L X = basic version / 316 L A = changeable rope 4 mm with gravity weight / 316 C = changeable rope 2 mm with centr. weight / 316 P = coax version 42.2 mm with multiple hole / 316 L certificate R = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db H = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex ia IIC T6, Ga, Ga/Gb (IECEx TUN 12.0009X) J = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d IIC T6, Ga/Gb (IECEx TUN 12.0011X) I = Ex t IIIC T... IP6X, Da, Da/Db, Da/Dc, Db Ex d ia IIC T6, Ga/Gb (IECEx TUN 12.0019X) optional version differentiation, without relevance for explosion protection Description: The guided radar sensor type VEGAFLEX FX8*(*). I * * ** * * * * * * * is used for level measurement in vessels of all types containing powdery or grainy bulk solids. High frequency microwave impulses are guided along a rod resp. a rope and reflected when they reach the product surface. The pulse transmit time is analysed.

Certificate No.: IECEx BVS 12.0066 Page 5 of 7 Type VEGAFLEX FX8*(*).II****H/A***** Supply and signal circuit U = 14 V 35 V DC (terminals 1(+), 2(-)) Um = 253 V AC/DC Type VEGAFLEX FX8*(*).IR****H/A***** Supply and signal circuit U = 9.6 V 30 V DC (terminals 1 [+], 2 [-] in the electronics Um = 30 V DC enclosure or in the terminal compartment regarding the two cell enclosure version) Type VEGAFLEX FX8*(*).IJ****H/A***** Supply and signal circuit U = 9.6 V 35 V DC (terminals 1(+), 2(-)) Um = 35 V DC Type VEGAFLEX FX8*(*).IR/I****U***** Supply and signal circuit U = 8 V 30 V DC (terminals 1(+), 2(-)) U m = 30 V DC Signal circuit U max = 5 V DC (terminals MB(+), MB(-)) MODBUS-signal (telegramme) U m = 30 V DC USB U max = 5 V DC (6 pin mini USB bush) USB-signal (USB-protocol) U m = 30 V DC Type VEGAFLEX FX8*(*).IR/I****B***** Supply and signal circuit U = 90 V 253 V DC (terminals 1(+), 2(-)) U m = 253 V AC aktive 4-20 ma signal circuit I out = 4-20 ma with superposed HART-signal (terminals 5(+),7(-)) U m = 60 V AC/DC passive 4-20 ma signal circuit I in = 4-20 ma with superposed HART-signal (terminals 6(+), 7(-)) U m = 60 V AC/DC Type VEGAFLEX FX8*(*).IR/J****I***** Supply and signal circuit U = 9.6 V 48 V DC / 42 V AC (terminals 1(+), 2(-)) U m = 253 V AC active 4-20 ma signal circuit I out = 4-20 ma with superposed HART-signal (terminals 5(+),7(-) U m = 60 V AC/DC passive 4-20 ma signal circuit I in = 4-20 ma with superposed HART-signal (terminals 6(+), 7(-)) U m = 60 V AC/DC

Certificate No.: IECEx BVS 12.0066 Page 6 of 7 Type VEGAFLEX FX8*(*).IH****H/A***** Supply and signal circuit (terminals 1(+), 2(-) in the electronics or in the terminal compartment regarding the two cell enclosure version) in type of protection Intrinsic Safety Ex ia IIC for connection to a certified intrinsically safe enclosure circuit maximum values: Ui = 30 V Ii = 131 ma Pi = 983 mw effective internal inductance Li = 5 H, in the two cell enclosure version Li = 10 H effective internal capacitance negligible Intrinsic safe signal circuits, electronics compartment Type VEGAFLEX FX8*(*).IR/H****H/A***** adjustment and indication circuit in type of protection Intrinsic Safety Ex ia IIC (terminals 5, 6, 7, 8) for connection to the intrinsically safe signal circuit of the associated VEGA adjustment and indication unit VEGADIS61or VEGADIS81 L cable 212 H C cable 1.98 F Type VEGAFLEX FX8*(*).IR/H****H/A*****, Type VEGAFLEX FX8*(*).IR/I****B/I/U***** adjustment and indication circuit (spring contact) in type of protection Intrinsic Safety Ex ia IIC for connection to the VEGA adjustment and indication unit PLICSCOM or to the interface adapter VEGACONNECT Non- intrinsic safe signal circuits, electronics compartment Type VEGAFLEX FX8*(*).IR****H/A***** adjustment and indication circuit (terminals 5, 6, 7, 8) For connection to the signal circuit of the associated VEGA adjustment and indication unit VEGADIS81, type VEGADIS DIS81.RX** Thermal parameter Permitted temperature range At the sensor (zone 20 or 21) type VEGAFLEX FX81 VEGAFLEX FX81(*).I****A/G/M/N****** -40 C.+150 C VEGAFLEX FX81(*).I****F/P****** -20 C.+150 C VEGAFLEX FX81(*).I****D/L****** -20 C.+200 C type VEGAFLEX FX82 VEGAFLEX FX82(*).I****A/B****** -40 C.+150 C VEGAFLEX FX82(*).I****F/H****** -40 C.+150 C VEGAFLEX FX82(*).I****K****** -20 C.+200 C type VEGAFLEX FX83 VEGAFLEX FX83(*).I****X****** -40 C.+150 C VEGAFLEX FX83(*).I****C****** -20 C.+130 C VEGAFLEX FX83(*).I****K****** -20 C.+150 C

Certificate No.: IECEx BVS 12.0066 Page 7 of 7 type VEGAFLEX FX86 VEGAFLEX FX86(*).I****1****** -196 C.+280 C VEGAFLEX FX86(*).I****2****** -196 C.+450 C At the electronics enclosure (Zone 20 or 21) -40 C.+60 C Maximum surface temperature At the sensor (zone 20 or 21) VEGAFLEX FX8*(*).I****A/H/B/I****** VEGAFLEX FX8*(*).I****U****** At the electronics enclosure (Zone 20 or 21) VEGAFLEX FX8*(*).IR/I***B/I****** VEGAFLEX FX8*(*).IR/I***U****** VEGAFLEX FX8*(*).IJ***A/H****** VEGAFLEX FX8*(*).IR/H***A/H****** process temperature + 2 K process temperature + 10 K with temperature fuse limited to 102 C ambient temperature + 60 K ambient temperature + 29 K ambient temperature + 12 K Degrees of protection according to IEC 60529 IP 66