Style 5. Style 7 AFNOR/DHF INSTALLATION AND OPERATING INSTRUCTIONS. Réf.: M

Similar documents
Minute Impulse Clock Controller I01DN

Operating Instructions for Digital Manometer. Model: MAN-SD

Meteorological Station P03/3-RS485-WAGO

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

Installation guide 862 MIT / MIR

A clock designed in close consultation with people living with Dementia.

Installation and Operation Manual. AllSync Plus Wired Clocks

Lamp and Control Panel (Lamp Panel)

WT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

To Set Time: Turn the set knob on back of the clock movement in either direction.

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Weather Station P03/3-RS485 with RS485 Interface

Zone Clocks. Installation Manual. Version Number 2.0 Current as of July 20, The Sapling Company, Inc. 670 Louis Drive Warminster, PA USA

Weather Station P03/3-Modbus-GPS for Modbus

Weather Station P03/3-RS485-GPS with RS485 Interface

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD

B Left-hand case side (x1) F

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

OPERATING MANUAL. EIB-Kombisensor AS 315 N

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

2 ACCESSING VARIOUS MODES

SVH with HYDROVAR (HVL range)

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

ISEmax CAM40/CAS40. Technical Information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Wireless Weather Station Instruction Manual

3B SCIENTIFIC PHYSICS

Drive electronics pq12

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

16 Input AC Block I/O Module

The Weather Station FEATURES:

LED light engines LED linear / area. Module QLE G3+ ADV Modules QLE ADVANCED

LED light engines LED linear / area

INE-PHS-3E ph Meter Operating Manual

Data Sheet / Instructions. Dewpoint MeterO

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE STARK-CLE EM STARK-CLE EM-SO Ø315

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

Installation and User Instructions

32 Input AC Block I/O Module

PHOENIX CONTACT - 04/2016. Features

Dewpoint Meter Data Sheet / Instructions

PHASED OUT. LED light engines LED linear / area. Module CLE Quadrant G2 ADV Modules CLE ADVANCED

P03/3-RS485-WAGO. Weather Station with RS485 Interface. Technical specifications and installation instructions

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

LED light engines LED linear / area. Module CLE Quadrant G3 ADV Modules CLE ADVANCED

Contents. English 1. French 56. Spanish

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

VK2 volume flow controller Overview

FOR CAN-AM ATV s P/N ASSEMBLY / OWNERS MANUAL

LED light engines LED compact. Module DLE G4 ADV Modules DLE

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

Surface-mounting thermostats Series ATH

PLOW MOUNT KIT FOR YAMAHA VIKING P/N ASSEMBLY / OWNERS MANUAL. Application PLOW PUSH FRAME NO or

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

APPMODULE WEATHER App Documentation

LED light engine / OLED LED linear / area. Module QLE Shallow G1 ADV Modules QLE ADVANCED

Cardiff Astronomical Observatory

Operating instructions Vortex flow meter. SVxxx / / 2015

Kingspan Smart-Lite Kite Luminaire

USER GUIDE AIR MINDER PLUS INDOOR AIR QUALITY/HEAT RECOVERY WHOLEHOUSE VENTILATION SYSTEMS FROM IMPORTANT: TO BE LEFT WITH END USER

Suntracer KNX-GPS. Weather Station. Technical specifications and installation instructions Item number 3093

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE

LED modules LED linear / area

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

THF / 1SCC330001M THF 1S1 C

PHASED OUT. LED light engines LED linear / area. Module QLE G1 471x462mm 5000lm SNC Modules QLE ESSENCE

FOR POLARIS ATV s P/N ASSEMBLY / OWNERS MANUAL

POINTS OF CAUTION BEFORE USE...

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK QLE G2 CLASSIC STARK QLE

473 Dew Point Hygrometer

Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE Shallow G1 ADV Modules QLE ADVANCED

WS-7391U Wireless 433 MHz Radio-controlled Weather Station. Instruction Manual

LED light engine / OLED LED linear / area

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

Emergency lighting units EM Inverter

LOW POWER SCHOTTKY. GUARANTEED OPERATING RANGES ORDERING INFORMATION PLASTIC N SUFFIX CASE 648

Operating instructions Pressure sensor PN / / 2007

WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

LED light engines LED linear / area

INSTALLATION INSTRUCTIONS FRONT PLOW MOUNT KIT Part Number: Application: Polaris Sportsman 400, 500, 800

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

One-Year Limited Warranty

Circular Motion and Centripetal Force

WARNING. INJURY HAZARD Failure to observe these instructions could lead to severe injury or death.

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

Transcription:

Style 5 Style 7 AFNOR/DHF INSTALLATION AND OPERATING INSTRUCTIONS B.P. 1 49340 TRÉMENTINES FRANCE Tél. : 02 41 71 72 00 Fax : 02 41 71 72 01 www.bodet.com Réf.: 605827 M When receiving goods please check nothing is broken otherwise make a claim near shipping company.

Table of contents 1) INITIAL CHECKS................................. 3 2) INSTALLATION OF AND ELECTRIC POWER SUPPLY FOR STYLE CLOCKS..... 3 3) LOCATION OF THE SELECT AND + KEYS.................. 5 4) CONFIGURATION................................. 6 4.1 DHF clock.............................. 8 4.2 AFNOR clock............................ 8 5) CONFIGURING A WORLD CLOCK........................ 10 6) DISPLAY BRIGHTNESS ADJUSTMENT..................... 11 7) DATA BACK-UP.................................. 11 8) CLEANING..................................... 11 APPENDIX : TECHNICAL FEATURES....................... 11 2

1) INITIAL CHECKS E S S E - In its original packaging, each Style clock is supplied clipped onto its wall holder, together with a cleaning kit (impregnated anti-static cloth), a bag containing 3 screws and 3 rawlplugs. - Unclip the holder (A) : insert your finger at the base of the opening (B), then pull firmly towards you. 1,5 mm 2 maxi D A B C 5 mm maxi - IMPORTANT : Product information Coded time input 115 or 230V Two descriptive labels are affixed to the back of the clock, and visible once the holder has been removed. One of them indicates the following information : Clock model (Style 5, Style 7,...), power supply, type of clock (refer to information below), other information such as the colour for example. Check that the Style clock which has been delivered to you is suitable for the intended mode of operation. REC. AFNOR The clock must be linked up to a coded time distribution network complying with the AFNOR or IRIG B extended DIEM. Radio DHF The clock is radio-synchronised by a DHF transmitter. Any operation not complying with the present instructions can cause irreversible damage to the clock, and renders the warranty invalid. The present instruction booklet concerns AFNOR and "DHF" clocks. For other models, please refer to the appropriate instruction booklet. Security rules : The installation and the maintenance service of this clock has to be done by skilled person. The installation has to be done according to the standard (NFC 15-100 for France). You need a 4A break circuit before the power supply. This break circuit has to be turned off in case of maintenance service. The power supply has to be turned on only after fixing the clock. Connection according to the installation instructions TN or TT. 2) INSTALLATION OF AND ELECTRIC POWER SUPPLY FOR STYLE CLOCKS - Wall mounting : fix the holder (A) in the chosen position, using the 3 rawlplugs and 3 screws supplied. 3

- Mounting on vertical bracket or ceiling bracket : the holder (A) fits the single-sided mounting bracket, P/N 936301, the double-sided mounting bracket, P/N 936300, and the double-sided chain suspension P/N 936302. Use the tapping screws supplied with the bracket. - A flush-mounting holder for Style 5 s clocks is also available, P/N 936306. This type of mounting is particularly suitable for operating theatres in hospitals and clinics. Mains connections : - Remove the black protective cover covering the terminal strip (C). Connect up the 115 or 230 Volt 50/60 Hz mains supply line to the terminal strip : Live and Neutral on terminals 1 and 2 (Wire max. section : 1.5 mm 2 with 5 mm bare). As this clock is classified on the 2 nd level, the connection to the earth is not required because it is not used. Put the protective cover back in place. Lock the wires with collars (S). N.B.: Style clocks have been designed for a 115 or 230 Volt ± 10 % mains supply. This clock is protected by a fuse (F1). Style 5 Style 5S and Style 7 Style 5D, Style 7D and 7E 0,5 A slow act ing 0,8 A slow act ing 4 A slow act ing 2 1 Mains supply 110 or 230VAC AFNOR clocks : - Connect the time coded line to terminals 7 and 8 on the terminal strip (D). There is no polarity. Coded time Mas ter clock D Style 5S Timer mode : If the clock is to be connected to a timer control unit : The timer control unit, P/N 936400, operates in count-up or count-down modes. Its various functions include : Start, Stop, Split Time, triggering of a relay at the end of the count-down or count-up operation (to stop at a pre-programmed time). The timer control unit can control up to ten Style 5 s clocks. Style 5 s clocks are equipped with a loose terminal strip (F), independent of the two terminal strips (C) and (D) fixed on the mounting. - Connect up the timer control unit to the terminal strip (F), using a 4 wires cable (T-, T+, and 2 wires for the 12 Volt supply). T- T+ 12V { F brown white green yel low 4

BT CHRONO RESET SPLIT STOP START - Chaining several Style 5 s clocks on the same timer control unit can be achieved by connecting all T- terminals together, as well as all T+ terminals together, using a 2 wires telephone cable. The first clock remains connected to the timer control unit through a 4 wires cable. H M Maxi 20m Maxi F F F 20cm Maxi 500m and 10 style 5S - For further information, please refer to the instructions relating to the timer control unit. Wall setting : - Clip the clock onto its holder, by introducing the two studs (E) into the two corresponding openings made in the back of the clock, and then by pressing firmly on the lower part of the clock, until it clicks into place. Take care not to jam the cables during this operation. E 1 - The clock can be subsequently unclipped from its holder, by pulling the lower part of the clock firmly towards you, and then by removing it via the top. 2 - You may now configure your Style clock, and adjust the display brightness. Please refer to Chapters 4 to 6. - Remove the protective sheet from the front panel and use the anti-static cloth to clean the clock. - Caution : if the AFNOR signal is lost, the clock continues to operate for 15 minutes in independent mode and then the display goes off. Only the separating column sign : remains on, indicating that power continues to be supplied to the clock. 3) LOCATION OF THE SELECT AND + KEYS - These two keys are located on the back of the clock, on the right on Style 5, Style 5 s and Style 5 date clocks, on the left on Style 7, Style 7 ellipse and Style 7 date clocks. - The Select key is above the + key. 5

4) CONFIGURATION To access this menu, first press the SELECT key, then keeping the SELECT key pressed down, press the + key for 3 seconds. It is possible to exit this menu at any time. All you have to do is to press the Select key, and then with the Select key pressed down, press the + key. Release the two keys afterwards. a - Selecting the operating mode The clock displays the previously selected operating mode : Operating Mode Coded Time Slave Clock World Clock Calibration Display Style 5, 5 s, 7 and 7 ellipse Style 5 date and 7 date Select the required operating mode using the + key. When the chosen operating mode (e.g. Cod ) appears on the display, press the Select key to enter your selection. The Calibration mode enables to display the version no., press the Select key to confirm. The clock displays 88:88" (all leds are on) and VV XX" (eg.: 26 80 means that the version no. is 2.6 and the calibration value is 80). Press the Select key to exit. In Coded Time Slave Clock mode, it displays the received coded time, without any modification. In World Clock mode, it computes and displays the local time, using the received coded time and its parameters for summer / winter daylight time changeover (paragraph c) and time lag (paragraph d). b - 12 or 24H display selection The clock displays 24 H (time display from 0:00 to 23:59) or 12AM (UK/USA display from 1:00 to 12:59). - You can choose one of these options using the + key. Enter by pressing the Select key. c - Style 5, Style 5 s, Style 7 and Style 7 ellipse clocks Using the + key, select the type of display required from one of the following four options : - The current time blinks (e.g. 20:29). This selection corresponds to the most frequent mode of operation : permanent time display. - 31 12" blinks : this selection corresponds to an 6

alternate display of the time and of the date (day-month). - 12 31" blinks : this selection corresponds to an alternate display of the time and of the date, in the USA manner (month - day). - 52" blinks : this selection corresponds to an alternate display of the time and of the week number. Enter by pressing the Select key. This last pression allows to exit the configuration menu. d - Style 5 date and Style 7 date clocks The language blinks : F = French N = Norwegian GB = English S = Swedish SP = Spanish DK = Danish D = German FI = Finnish I = Italian CA = Catalan P = Portuguese BA = Basque NL = Dutch GA = Gallego - Select the desired language using the + key, then enter by pressing the Select key. - Using the + key, choose any second language as required for alternate display. If you select - -, only the first language will be used. Enter by pressing the Select key. For a Style 5 date clock, this last pression allows to exit the configuration menu. e - Style 7 Date clocks Using the + key, select the type of central display required from one of the following two options : - Day of the week (MON, TUE,..., SUN) - 52". This selection corresponds to a week number display. Enter by pressing the Select key. This last pression allows to exit the configuration menu. The clock then returns to the display mode corresponding to its normal use. 7

4.1 DHF clock Caution: when installing the clock, the master clock Sigma or the transmitter must be set to INIT mode. On leaving the factory, the DHF clock is set in Initialisation mode and on the initial powering up the time is initialised at 00h00mn00ss on 01/01/2000. It memorises the address of the transmitter and switches to normal mode automatically when time is received. If needed (change of communication channel, new installation ), the clock can be switched to Initialisation mode by pressing [SEL] button for more than 6 seconds. The clock displays 00h00mn on 01/01/2000. The DHF radio clocks are set as AFNOR time code receivers. 4.2 AFNOR clock a - Selecting the Code Code AFNOR NF S 87-500-A IRIG B Extended DIEM Display Style 5, 5 s, 7 and 7 ellipse Style 5 date and 7 date Select the code using the + key, then enter your selection using the Select key. If you do not know which code is supplied by the master clock : If the selected code on the Style Clock is different from the one managed by the master clock, then the Style clock may either : - Refuse entirely the coded time message : the clock can not be set to time. - or be confused between both codes. It will be set automatically to the right time, but with a wrong date. In both cases, try another code. The chart below described the information available for both codes. AFNOR NF S 87-500-A DIEM s Ex tended IRIG B Seconds (00 to 59) Seconds (00 to 59) Minutes (00 to 59) Minutes (00 to 59) Hours (00 to 23) Hours (00 to 23) Julian Date (001 to 366) Day of week (1 to 7) Year (00 to 99) Day of month (01 to 31) Month (01 to 12) Year (00 to 99) 8

b - Summer / Winter time changeover selection, only if the operating mode selected is LOC (World Clock). Using the + key, select the required country of reference for the summer / winter time changeover, then enter your selection using the Select key. Country of Reference No changeover Europe, except for the United Kingdom United Kingdom United States / Canada Australia Display Style 5, 5 s, 7 and 7 ellipse Style 5 date and 7 date Rules used by the Style clock to define the periods of Daylight Time Europe, except for United Kingdom: from last Sunday of March to last Sunday of October. All changeovers occur at 1.00 AM GMT. United Kingdom : from last Sunday of March to the day after the 4 th Saturday of October. All changeovers occur at 1.00 AM GMT. United States / Canada : from the second Sunday of March to the first Sunday of November. All changeovers occur at 2.00 AM Local Time. Australia : from first Sunday of October to first Sunday of April. All changeovers occur at 2.00 AM Local Time. c - Time Lag selection, only if the operating mode selected is LOC (World Clock) The time lag blinks (00 by default). - Select the time lag required, from -15 h to +15 h, using the + key, then enter by pressing the Select key. The selected time lag will be only effective after 2 correct receptions of the coded time message, i.e. about 3 seconds. 9

5) CONFIGURING A WORLD CLOCK NEW-YORK LONDON PARIS TOKYO SYDNEY - Use as many AFNOR Style Clocks as towns concerned. Connect them (as explained in Chapter 2) to an AFNOR (or extended IRIG B) Coded Time Master Clock, e.g. an AFNOR Emitting Style 7 date. - Important : configure the Coded Time Master Clock so that it generates G.M.Time. No summer / winter daylight time changeover. - As described in Chapter 4, configure each AFNOR Style Clocks selecting LOC (World Clock) as to the operating mode, and choosing the adequate Reference Country (for automatic daylight time changeover) and Time Lag, depending on the town which local time you want to display. Time Lag = Winter Time - Greenwich Mean Time Daylight Time = Winter Time + 1 hour. Examples : Town Ref er ence Coun try Time Lag LOS ANGELES United States / Canada - 08 MEXICO No changeover - 06 CHICAGO United States / Canada - 06 NEW-YORK, TORONTO United States / Canada - 05 BUENOS-AIRES No changeover - 04 LONDON United Kingdom 00 PARIS * Europe, except for UK + 01 HELSINKI, ATHENS Europe, except for UK + 02 JOHANNESBURG No changeover + 02 MOSCOU Europe, except for UK + 03 HONG-KONG ** No changeover + 08 TOKYO, SEOUL No changeover + 09 SYDNEY Australia + 10 Notes : * Paris, as well as Frankfurt, Madrid, Stockholm, Oslo, Zürich, Milan, Amsterdam, ** Hong-Kong, as well as Tai-Pei, Bangkok, Singapore, Kuala Lumpur, Beijin,... 10

6) DISPLAY BRIGHTNESS ADJUSTMENT - The display brightness can be adjusted when the Style clock is in normal operating mode, i.e. when the clock is neither in the configuration menu, nor in the time-setting menu. - By pressing the + key several times in succession, you can directly select the level of display brightness most suited to the level of ambient lighting, from the four brightness levels proposed. 7) DATA BACK-UP - Style clocks possess a permanent data back-up facility which permits the clock to store all the configuration parameters and display selections, even in the event of a prolonged mains power failure. 8) CLEANING Use an anti-static cleaner similar to that supplied in the original packaging. Never use cleaning spirits, acetone or any other solvents which are likely to damage the casing and the filter of your Style clock. APPENDIX : TECHNICAL FEATURES The Style clocks are compliant to the electromagnetic standard 89/336/CEE They are designed for indoor use. They are compliant with the following European standards : NF EN 55022 (December 1994). NF EN 50082-1 (June 1992). EN 60950 - Power supply : 115 or 230 V ± 10 % 50/60 Hz. - Operating temperature : 0 to 50 C - Protection index : IP30 These clocks are protected by a fuse (F1). Style 5 Style 5S and Style 7 Style 5D, Style 7D and 7E 0,5 A slow act ing 0,8 A slow act ing 4 A slow act ing 11

Style 5 - Size (in mm) : - Weight : 0,8 kg - Maximum nominal current : 40 ma Style 5S - Size (in mm) : - Weight : 1 kg - Maximum nominal current : 55 ma Style 5D - Size (in mm) : - Weight : 1,6 kg - Maximum nominal current : 100 ma Style 7 - Size (in mm) : - Weight : 1,1 kg - Maximum nominal current : 65 ma Style 7D - Size (in mm) : - Weight : 2,2 kg - Maximum nominal current : 150 ma Style 7E - Size (in mm) : - Weight : 2,1 kg - Maximum nominal current : 80 ma. Wall bracket 50.25 8 7 6 5 9 69 69 165 12 42.5 63.9 4.2 230V.AC 74.12 8 50.25