Sputter Ion Pump (Ion Pump) By Biswajit

Similar documents
ION Pumps for UHV Systems, Synchrotrons & Particle Accelerators. Mauro Audi, Academic, Government & Research Marketing Manager

VARIAN SPUTTER ION PUMPS A 50 YEAR HISTORY

Ultra-High Vacuum Technology. Sputter Ion Pumps l/s

Ion Pump Applications

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

AGILENT SPUTTER ION PUMPS A 60 YEAR HISTORY

Vacuum. Kai Schwarzwälder, Institut für Physik Universität Basel October 6 th 2006

( KS A ) (1) , vapour, vapor (USA) , saturation vapour pressure. , standard reference conditions for gases. , degree of saturation

Repetition: Practical Aspects

Electrical Discharges Characterization of Planar Sputtering System

Repetition: Physical Deposition Processes

NEXTorr HV 100 HIGHLIGHTS

NEXTorr Z 100 HIGHLIGHTS

Earlier Lecture. In the earlier lecture, we have seen non metallic sensors like Silicon diode, Cernox and Ruthenium Oxide.

6.5 Optical-Coating-Deposition Technologies

TMT4320 Nanomaterials November 10 th, Thin films by physical/chemical methods (From chapter 24 and 25)

VACUUM PUMPING METHODS

To move a particle in a (straight) line over a large distance

Vacuum II. G. Franchetti CAS - Bilbao. 30/5/2011 G. Franchetti 1

Vacuum. Residual pressure can thwart the best cryogenic design. Each gas molecule collision carries ~kt from the hot exterior to the cold interior.

Table of Content. Mechanical Removing Techniques. Ultrasonic Machining (USM) Sputtering and Focused Ion Beam Milling (FIB)

Lecture 10. Vacuum Technology and Plasmas Reading: Chapter 10. ECE Dr. Alan Doolittle

(1) E. & F. N. SPON London VACUUM MANUAL. Edited by. W. Steckelmacher. J. Yarwood. L. Holland

Previous Lecture. Electron beam lithoghraphy e - Electrons are generated in vacuum. Electron beams propagate in vacuum

CapaciTorr B MK5

CHAPTER 6: Etching. Chapter 6 1

Huashun Zhang. Ion Sources. With 187 Figures and 26 Tables Э SCIENCE PRESS. Springer

Introduction to Plasma

D- Charge Exchange Ionizer for the JINR Polarized Ion Source POLARIS

Effect of Spiral Microwave Antenna Configuration on the Production of Nano-crystalline Film by Chemical Sputtering in ECR Plasma

Generation of vacuum (pumps): Vacuum (pressure) measurements:

Ion Getter and Titanium Sublimation Pumps. Ion Getter Pumps (IGP)

1 AT/P5-05. Institute of Applied Physics, National Academy of Sciences of Ukraine, Sumy, Ukraine

Characterization of the operation of RITs with iodine


Chapter 13: Partial Pressure Analysis

Semiconductor Technology

Generation of vacuum (pumps) and measurements

Vacuum for Accelerators

LECTURE 5 SUMMARY OF KEY IDEAS

Chapter Six: X-Rays. 6.1 Discovery of X-rays

Chapter 2 Atoms and Elements

Vacuum Technology for Particle Accelerators

Chapter 37 Early Quantum Theory and Models of the Atom

MICROCHIP MANUFACTURING by S. Wolf

A SMALL GETTER ION-PUMP

Etching Issues - Anisotropy. Dry Etching. Dry Etching Overview. Etching Issues - Selectivity

Section 5: Thin Film Deposition part 1 : sputtering and evaporation. Jaeger Chapter 6. EE143 Ali Javey

Optimized Annular Triode Ion Pump for Experimental Areas in the LHC

FLASH CHAMBER OF A QUASI-CONTINUOUS VOLUME SOURCE OF NEGATIVE IONS

Extrel Application Note

Valence Electrons. How do you find the number of valence electrons in an atom of a representative element?

DPP06 Meeting of The American Physical Society. Production of negative ion plasmas using perfluoromethylcyclohexane (C 7 F 14 )

THE GASEOUS STATE OF MATTER

Chem!stry. Atomic Structure and Chemical Bonding Concepts: Change, Models & Systems

Mass Spectrometry in MCAL

PHYSICAL VAPOR DEPOSITION OF THIN FILMS

Deuterium Gas Analysis by Residual Gas Analyzer

JARA FIT Ferienprakticum Nanoelektronik Experiment: Resonant tunneling in quantum structures

EE 527 MICROFABRICATION. Lecture 24 Tai-Chang Chen University of Washington

Characterization of low pressure plasma-dc glow discharges (Ar, SF 6 and SF 6 /He) for Si etching

Lecture 4. Ultrahigh Vacuum Science and Technology

NANOSTRUCTURED CARBON THIN FILMS DEPOSITION USING THERMIONIC VACUUM ARC (TVA) TECHNOLOGY

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Unit Two Test Review. Click to get a new slide. Choose your answer, then click to see if you were correct.

Rough (low) vacuum : Medium vacuum : High vacuum (HV) : Ultrahigh vacuum (UHV) :

Lecture PowerPoints. Chapter 27 Physics: Principles with Applications, 7th edition Giancoli

3. Photons of which of the following colors of light possess the greatest amount of energy? A) blue B) green C) yellow D) red

POLARIZED DEUTERONS AT THE NUCLOTRON 1

Keywords. 1=magnetron sputtering, 2= rotatable cathodes, 3=substrate temperature, 4=anode. Abstract

Secondary Ion Mass Spectrometry (SIMS)

1.1 The Fundamental Chemistry of life

VACUUM SYSTEM FOR STANFORD STORAGE R7NG, SPEAR* U. Curmnings, N. Dean, F. Johnson, J. Jurow, J. Voss ERRATA

Discovered by German scientist Johann Hittorf in 1869 and in 1876 named by Eugen Goldstein.

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

CHEMISTRY Matter and Change. Chapter 12: States of Matter

Study of Distributed Ion-Pumps in CESR 1

Modern Methods in Heterogeneous Catalysis Research: Preparation of Model Systems by Physical Methods

Metal Deposition. Filament Evaporation E-beam Evaporation Sputter Deposition

CapaciTorr HV Pumps. making innovation happen,together

Gaetano L Episcopo. Scanning Electron Microscopy Focus Ion Beam and. Pulsed Plasma Deposition

UNIT 3. By: Ajay Kumar Gautam Asst. Prof. Dev Bhoomi Institute of Technology & Engineering, Dehradun

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Anomalous production of gaseous 4 He at the inside of DScathode during D 2 O-electrolysis

Ions 7.1. Slide 1 of 39. Copyright Pearson Prentice Hall

Plasma Deposition (Overview) Lecture 1

SPECTRAL INVESTIGATION OF A COMPLEX SPACE CHARGE STRUCTURE IN PLASMA

EE143 Fall 2016 Microfabrication Technologies. Lecture 6: Thin Film Deposition Reading: Jaeger Chapter 6

X-RAY PRODUCTION. Prepared by:- EN KAMARUL AMIN BIN ABDULLAH

Some Reflections on Gas Discharges and PAGD Pulses

Describe how the inter-conversion of solids, liquids and gases are achieved and recall names used for these inter-conversions

Chemistry B11 Chapter 3 Atoms

Regenerative Soot-II: Emission o f carbon clusters from sooting plasma

Elements and Reactivity Revision Notes

CapaciTorr HV 200 HIGHLIGHTS

Discharge Cell Design. Some initial explorations, considerations and open questions

e - Galvanic Cell 1. Voltage Sources 1.1 Polymer Electrolyte Membrane (PEM) Fuel Cell

Study of DC Cylindrical Magnetron by Langmuir Probe

Transcription:

Sputter Ion Pump (Ion Pump) By Biswajit 08-07-17

Sputter Ion Pump (Ion Pump) An ion pump is a type of vacuum pump capable of reaching pressures as low as 10 11 mbar under ideal conditions. An ion pump ionizes gas within the vessel it is attached to and employs a strong electrical potential, typically 3 7 kv, which allows the ions to accelerate into and be captured by a solid electrode and its residue. Early History of Ion Pump: The first ion pump was invented by Varian Associates. Varian Associates was one of the first high-tech companies in Silicon Valley. It was founded in 1948 by Russell H. and Sigurd F Varian, William Webster Hansen and Edward Grinzton. Then Robert Jepsen led the investigation about electronic vacuum pumping in 1957 to the realization of the first sputter ion pump (SIP). Lewis Hall and John Helmer were members of the research team, involved in the choice of the most suitable cathode material and in the optimization of the ion pump design. Renn Zaphiropoulos worked on high voltage feedthroughs, magnets, control units, systems, flanges, valves, sorption pumps and Titanium Sublimation Pumps (TSP) in 1957. In 1960 the slotted titanium cathode, named Super VacIon Pump, was introduced on the basis of observations about noble gas pumping mechanism and unstable Argon pumping phenomena.

Types of Ion Pump: There are three main types of ion pumps: the conventional or standard diode pump, the noble diode pump and the triode pump. 1. Standard diode pump: A standard diode pump is a type of ion pump employed in high vacuum processes which contains only chemically active cathodes. 2. Noble diode pump: A noble diode pump is a type of ion pump used in high-vacuum applications that employs both a chemically reactive cathode, such as titanium, and an additional cathode composed of tantalum. The tantalum cathode serves as a high-inertia crystal lattice structure for the reflection and burial of neutrals, increasing pumping effectiveness of inert gas ions. 3. Triode pump: The triode sputter ion pumps are employed to create hydrocarbon-free ultra high vacuum. They utilize the high intensity cold cathode discharge produced in a magnetic field to sputter a highly reactive metal. The reactive metal layer called getter film combined with the active gas molecules such as hydrogen, nitrogen, oxygen, water vapour etc to form low vapour pressure stable compounds, thus reducing the number of gas molecules and hence gas pressure in the system volume.

Working Principle: Step 1: Create a high magnetic field: The ion pumps have magnets located outside the vacuum. Those magnets generate a 1200 gauss magnetic field, which contains and guides electrons within circular anode rings. Step 2: Generate a plasma: After an initial rough pumping to remove much of the gas, high voltage is applied to the element assembly. Electrons are pulled into the anode tube assembly where they spin in a cloud; this cloud is commonly referred to as plasma. The plasma is trapped by the high magnetic field. Step 3: Ionize gas molecules: As gases move into the anode assembly, electrons strike the gas molecules. This collision removes electrons from the gas molecule's valence shell, and changes the gas molecule into a positive ion (it has a positive charge). The positive ion is forced out of the anode tube by the high voltage field at a high velocity toward the cathode plate. Step 4: Capture gas ions: When the positive ion strikes the cathode plate, that impact is called sputtering. Cathode materials are ejected toward the anode tube and the ion chemically and physically reacts with the cathode material.

Applications: Ion pumps are commonly used in ultra-high vacuum (UHV) systems, as they can attain ultimate pressures less than 10 11 mbar. In contrast to other common UHV pumps, such as turbomolecular pumps and diffusion pumps, ion pumps have no moving parts and use no oil. They are therefore clean, need little maintenance, and produce no vibrations. These advantages make ion pumps well-suited for use in Transmission electron microscopy, scanning probe microscopy and other high-precision apparatuses. Disadvantage: Recent work has suggested that free radicals escaping from ion pumps can influence the results of some experiments. THANK YOU