The power of multi-detector SEC in the analysis of antibodies

Similar documents
How to use GPC/SEC for compositional analysis

GPC/SEC Analysis of Polymer Degradation

Differentiation of polymer branching and composition using the Mark Houwink plot

How switching mobile phases can improve your OMNISEC results

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

GPC/SEC Analysis of Polymer Solutions Used in Inkjet Printing

Component specific particle characterisation of the active components in a pharmaceutical topical formulations

Understanding the colloidal stability of protein therapeutics using dynamic light scattering

Use of DLS/Raman to study the thermal unfolding process of lysozyme

Introduction to the calculators in the Zetasizer software

Overcoming and quantifying Wall Slip in measurements made on a rotational rheometer

Nanobubble Applications and Characterization by Nanoparticle Tracking Analysis

DEVELOPING A BIOFORMULATION STABILITY PROFILE

10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS

Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS)

Determining cure profile and post-cure shrinkage of photopolymers using UV accessory on a rotational rheometer

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20

Evaluating the rheological properties of hyaluronic acid hydrogels for dermal filler applications

Studying the Effect of Steric Layer Thickness on Emulsion Stability

Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

Using rheology to study the hardness and spreadability of butter

Understanding the conformational stability of protein therapeutics using Raman spectroscopy

Characterization of Single Wall Carbon Nanotubes (SWNTs) by combining Dynamic Light Scattering and Raman Spectroscopy

Executive Summary. Introduction WHITEPAPER

The ultimate in desktop particle characterization

The ultimate in desktop particle characterization

Setting the Standard for Advanced GPC/SEC Systems

Measuring the rheology of thermoplastic polymer melts

Benefit of light scattering technologies (RALS/LALS/MALS) and multidetection characterization in life science research?

Malvern Macromolecular Solutions. Innovative Solutions in Material Characterization

Tips & Tricks GPC/SEC: From a Chromatogram to the Molar Mass Distribution

Using the Zetasizer Nano to optimize formulation stability

Setting the Standard for GPC. Complete Guide for GPC / SEC / GFC Instrumentation and Detection Technologies. The Right Instrument for Your Application

Laser diffraction and automated imaging: complementary techniques for nasal spray development

Investigating the Relationship Between the Rheological Properties of Hyaluronic Acid and its Molecular Weight and Structure using Multidetector

Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis

Latest Developments in GPC Analysis of Adhesive and Sealant Polymers Mark Pothecary PhD Americas Product Manager Malvern Instruments

Zeta potential - An introduction in 30 minutes

ZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight

Polymer analysis by GPC-SEC. Technical Note. Introduction

MALVERN OMNISEC RESOLVE, REVEAL, REALIZE MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

MALVERN OMNISEC RESOLVE, REVEAL, REALIZE MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

Measurements of protein electrophoretic mobility using the Zetasizer Nano ZSP

Gold Nanoparticle Applications and Characterization by Nanoparticle Tracking Analysis

Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Light Scattering Detection

Measuring the rheology of polymer solutions

Inform is a series of white papers designed to provide advice on material characterization issues. Mie theory The rst 100 years

Macromolecular Chemistry

Gel Permeation Chromatography (GPC) or Size Exclusion Chromatography (SEC)

Use of SEC-MALS. (Size Exclusion Chromatography - Multi Angle. Light Scattering) for protein quality and characterization

Progress toward reliable NC molecular mass distribution by GPC

Tips & Tricks GPC/SEC: Inter-Detector Delay

Tips & Tricks GPC/SEC: Protein Analysis with Size-Exclusion Chromatography

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How?

Sepax SRT -C, Zenix -C SEC Phases

An Introductions to Advanced GPC Solutions

GPC / SEC Theory and Understanding

Characterization of polyphenylene sulphide using the Agilent PL-GPC 220 High Temperature GPC System with triple detection

Sample measurements to demonstrate Zetasizer specifications (Zetasizer Nano, Zetasizer APS, Zetasizer μv)

Determination of Polymer Modifier in Asphalt

Biophysical characterization of SMALPs and nanodiscs

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Dr. Christoph Johann Wyatt Technology Europe GmbH Copyright Wyatt Technology Europe GmbH All Rights reserved 1

Size Exclusion Chromatography in the Presence of an Anionic Surfactant

Analysis of Star Polymers Using the Agilent 1260 Infinity Multi-Detector GPC/SEC System

Analysis of PEGylated Proteins with Agilent AdvanceBio SEC Columns

GPC/SEC An essential tool for polymer analysis

Precision and accuracy of protein size determination using the ActiPix TDA200 Nano-Sizing System

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

The Diffusion Barrier Technique, Practical Aspects and Data interpretation

next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

Comparison of Polymer Separation by Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation

High Performance Liquid Chromatography

Particle Characterization Laboratories, Inc.

MODERN HPLC FOR PRACTICING SCIENTISTS

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

Peptide Isolation Using the Prep 150 LC System

Advanced GPC. GPC On Tour, Barcelona, 28 th February The use of Advanced Detectors in GPC

EcoSEC - semi-micro GPC/SEC system for high throughput polymer analysis

Protein Aggregate Assessment of Ligand Binding Assay (LBA) Reagents Using SEC-MALS

GPC - Gel Permeation Chromatography. aka Size Exclusion Chromatography- SEC

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

Waters GPC User Guide and Tutorial for Using the GPC in the Reynolds Research Group 2 nd Edition: April 2012

MACROIMS MACROION MOBILITY SPECTROMETER MOLECULAR WEIGHT AND PARTICLE SIZE DETERMINATION OF POLYVINYLPYRROLIDONE (PVP)

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

Electrophoretic Light Scattering Overview

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Practical Steps in GPC Method Development

GPC/SEC standards. Product guide

Gel Permeation Chromatography

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

GPC/SEC standards. Product guide

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Novel instrumentation to gain insight into the aggregation state of proteins by Taylor Dispersion Analysis: a comparison

ZETASIZER NANO Series PERFORMANCE, SIMPLICITY, VERSATILITY

Transcription:

The power of multi-detector SEC in the analysis of antibodies How OMNISEC can measure antibody absolute MW independent of size and structural changes MOLECULAR SIZE MOLECULAR STRUCTURE MOLECULAR WEIGHT PROTEIN AGGREGATION PROTEIN STABILITY Introduction Antibodies have generated keen interest from the pharmaceutical / biopharma / biotherapeutic industries due to their ability to direct their neutralization attack toward specific structures in harmful agents. As a naturally occurring class of molecules, developments have been made that now allow scientists to produce antibodies in laboratory settings. Since much of an antibody s functionality depends on its molecular structure and integrity, full characterization, including molecular weight, size, and purity of these materials is critical to ensure efficacy. Size-exclusion chromatography (SEC), also referred to as gel permeation chromatography (GPC), is a widely used technique to characterize a range of samples, from bulk manufactured materials to proteins and other biological macromolecules, such as antibodies. This technique can be used to measure the molecular weight moments, molecular weight distribution, intrinsic viscosity and hydrodynamic size of these materials. Figure 1 shows a complete setup of Malvern s OMNISEC SEC system. A brief overview of how SEC works: a solvated sample is carried by a liquid mobile phase through an analytical column full of porous gel particles, where diffusioncontrolled separation of the macromolecular components occurs and is ultimately observed by different detectors as each slice of sample elutes. The samples elute based on molecular size, with the larger molecules eluting first. It is important to remember that the elution order is based on molecular size and not molecular weight. The potency of the SEC analysis depends on which detectors are coupled to the chromatography. Two of the common types of SEC configurations are a column calibration SEC setup, and an advanced detection SEC setup. A column calibration SEC system employs a single concentration detector, usually a refractive index (RI) or UV detector, to compare the retention volume of analyte molecules through a Malvern Instruments Worldwide Sales and service centres in over 65 countries www.malvern.com/contact 2017 Malvern Instruments Limited

SEC column against that of a series of standards with known molecular weights. A common advanced detection SEC configuration utilizes a combination of RI, UV/Vis photodiode array (PDA), viscometer, and light scattering detectors to make direct measurements of samples molecular weight, intrinsic viscosity and molecular size, independent of retention volume or elution order. This application note will describe the analysis of three antibody samples using column calibration and advanced detection SEC. Comparisons will be made between the data derived from both methods highlighting the advantages of advanced detection. Figure 1: Malvern's OMNISEC tetra-detector SEC system. SEC experimental conditions Three antibody samples, 1, 2, and 3, were prepared in water at concentrations of about 0.5 mg/ml for SEC analysis using Malvern s OMNISEC system. The samples were analyzed using 2 P3000 in a mobile phase of phosphate-buffered saline (PBS) at a flow rate of 0.75 ml/min. The zero-waste mode for volume-economic sample delivery was to inject 100 µl of each sample. The autosampler, column, and detector compartments were maintained at 25 C throughout the analyses. SEC results The tetra detector chromatograms for the antibody samples are shown in Figures 2 4. The RI signal is presented in red, the UV/Vis PDA signal at 280 nm is purple, the viscometer signal is blue, and the right angle light scattering detector is green. LogMW is presented as a gold line. Figure 2: Tetra detector chromatogram of sample 1. Figure 3: Tetra detector chromatogram of sample 2. Figure 4: Tetra detector chromatogram of sample 3. All three samples show good chromatography, as evidenced by the detector signals returning to baseline. A cursory examination of the retention volume of each sample indicates that sample 3 elutes at the lowest elution volume (earliest elution time), followed by sample 1, and then finally sample 2. This trend is highlighted in the overlay of the refractive index chromatograms shown in Figure 5. Figure 5: Overlay of refractive index chromatograms of samples 1 (red), 2 (purple) and 3 (green). The conclusions that can be drawn from this comparison are that sample 3 possesses the largest molecular size of the three samples, followed by sample 1, with sample 2 having the smallest molecular size. It is important to note that the term molecular size was used to make the comparisons based on elution order, 2 The power of multi-detector SEC in the analysis of antibodies

not molecular weight. In many cases molecular size and molecular weight follow the same trends, but this is not absolutely true for all samples. In the following sections, the column calibration and advanced detection data will be discussed. In order to provide a fair comparison between the column calibration and advanced detection analysis methods, the same chromatographic data are used for both sets of calculations. Column calibration results A protein molecular weight marker kit (Sigma Aldrich) comprising six globular proteins and an exclusion limit marker was prepared in PBS at concentrations of approximately 1-3 mg/ml in order to provide a molecular weight profile for the column set. The molecular weights of the proteins ranged from 29 kda to 669 kda. The calibration curve generated is shown below in Figure 6. Figure 6: Calibration curve generated from six proteins with established molecular weight values. The molecular weight and dispersity values calculated for the antibody samples 1, 2, and 3 based on the protein calibration curve are presented in Table 1. Table 1. Molecular characterization data from column calibration for samples 1, 2, and 3. As expected based on the elution volumes shown in Figure 5 and the fact that the calibration curve in Figure 6 descends to lower molecular weight with increasing retention volume, the molecular weight calculated for sample 3 was the highest, at about 202 kda. Next was sample 1 at 143 kda, and last was sample 2 at about 97 kda. Based on the calibration curve shown in Figure 6, this range of molecular weights is consistent with the retention volume difference of over 1 ml (~16.1 17.2 ml) from the peak of sample 3 to the peak of sample 2. With a single detector column calibration SEC method, this relative molecular weight, as in relative to the protein standards used to create the calibration curve, is the extent of the molecular data available. Advanced detection results To examine these samples further, the molecular characterization data from advanced detection for samples 1, 2, and 3 (see Figures 2 4) are shown below in Table 2. The combination of concentration detectors with viscometer and light scattering detectors offers more comprehensive data, including the absolute molecular weight (Mw), dispersity (Mw/Mn), intrinsic viscosity (IV), and hydrodynamic radius (R H ). The dn/dc used for analysis was 0.185, typical of proteins in aqueous media. Table 2. Molecular characterization data from advanced detection for samples 1, 2, and 3. The obvious difference between the data obtained from column calibration and advanced detection is that relative molecular weights calculated from column calibration provided a range of values for the three antibody samples, while the 3 The power of multi-detector SEC in the analysis of antibodies

absolute molecular weight data from advanced detection correctly shows that all three antibody samples have the same molecular weight, about 150 kda. The dispersity values of approximately 1 agree with the flat LogMW trace in Figures 3 5 and indicate that these samples are discrete species. The advanced detection data also supports the molecular size trend observed from the elution order in Figure 5, as sample 3 has the highest IV and largest R H value, followed by sample 1, and last, sample 2. This means that the three antibodies have different molecular shapes, and it is those shape and size differences, not molecular weight differences, that cause them to elute at different retention volumes If the analysis of these antibody samples had relied solely on column calibration data, the molecular weight information obtained would have been inaccurate. For example, a researcher could come to the false conclusion that antibody sample 2 had a lower molecular weight due to the loss of its L polypeptide chains or that antibody sample 3 had a chemically-bound impurity or had aggregated. When in reality neither of these has occurred, and the different molecular sizes are due to unforeseen structural differences or conformation changes. The use of advanced detection, which employs a light scattering detector to measure absolute molecular weight independent of retention volume, offers accurate molecular weight data and reveals structural details not observable with column calibration techniques. For additional examples highlighting the need for advanced detection in order to obtain accurate molecular information about sample components, please see the related application note: Characterization of IgG monomers & their aggregates. Conclusions The data in this application note illustrates one of the most important benefits of advanced detection SEC. While column calibration SEC has been used successfully for many years, it relies on the dangerous assumption that molecular weight always trends with molecular size, and thus retention volume. While many materials exhibit this trend, there are a number of macromolecules with variable structures, such as the antibodies shown here, that do not. Column calibration SEC analysis of these types of materials can lead to dramatically incorrect qualitative and quantitative data and conclusions. Advanced detector SEC can not only measure absolute molecular weight, independent of molecular size and retention volume, but also provide structural information such as IV and R H. The ability to accurately determine the molecular weight and molecular size of antibodies is critical to provide researchers and manufacturers the information needed in order to maintain the sample purity and integrity required for specific applications. This kind of insight can allow for a deeper understanding, and ultimately control, of the behavior of these valuable materials and their subsequent end-use as therapeutics and other beneficial drugs. 4 The power of multi-detector SEC in the analysis of antibodies

Malvern Instruments Limited Grovewood Road, Malvern, Worcestershire, UK. WR14 1XZ Malvern Instruments is part of Spectris plc, the Precision Instrumentation and Controls Company. Spectris and the Spectris logo are Trade Marks of Spectris plc. All information supplied within is correct at time of publication. Malvern Instruments pursues a policy of continual improvement due to technical development. We therefore reserve the right to deviate from information, descriptions, and specifications in this publication without notice. Malvern Instruments shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Malvern Instruments owns the following registered trademarks: Bohlin, FIPA, Insitec, ISYS, Kinexus, Malvern, Malvern 'Hills' logo, Mastersizer, MicroCal, Morphologi, Rosand, 'SEC-MALS', Viscosizer, Viscotek, Viscogel and Zetasizer. 2017 Malvern Instruments Limited