Investigation of anomalous heat production in Ni-H systems

Similar documents
Figure 1: Two pressure shocks causing the sample temperature increase (Termocouple Tc1, figure 1b of reference [2]). 2 Heat production Apart from the

He II Heat transfer through a Corrugated Tube - Test Report

CORRELATED MEASUREMENTS OF D 2 LOADING AND 4 He PRODUCTION IN Pd LATTICE

LEP Stirling engine

NUCLEAR TRANSMUTATION IN DEUTERED PD FILMS IRRADIATED BY AN UV LASER

Evidence for Tritium generation in Self-heated Nickel Wires subjected To Hydrogen Gas Absroption/Desorption Cycles

Reproduction of Fleischmann and Pons experiments

THERMAL BEHAVIOR OF POLARIZED Pd/D ELECTRODES PREPARED BY CO-DEPOSITION

Renewable Energy. Theory: The Ideal Gas Law The equation of state for an ideal gas is written: PV = nrt

Photon and particle emission, heat production and surface transformation in Ni-H system

Observation of Excess Heat by Activated Metal and Deuterium Gas

A Mass-Flow-Calorimetry System for Scaled-up Experiments on Anomalous Heat Evolution at Elevated Temperatures

PAPER 2 THEORY QUESTIONS

A New Energy caused by Spillover-Deuterium

Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar

THE PRECURSOR OF "COLD FUSION" PHENOMENON IN DEUTERIUM/ SOLID SYSTEMS

Report Liquid Hydrogen Target for the COMPASS Experiment

Apparatus to measure high-temperature thermal conductivity and thermoelectric power of small specimens

Temperature Scales. Temperature, and Temperature Dependent on Physical Properties. Temperature. Temperature Scale

PROGRESS IN GAS-LOADING D/Pd SYSTEM. The feasibility of a self-sustaining heat generator

ANOMALOUS HEAT FLOW AND ITS CORRELATION WITH DEUTERIUM FLUX IN A GAS-LOADING DEUTERIUM-PALLADIUM SYSTEM

However, in matter, magnetic induction depends on magnetization M in the following way:

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

Laboratory 12: Three Thermodynamics Experiments

Anomalous production of gaseous 4 He at the inside of DScathode during D 2 O-electrolysis

Stirling engine with Cobra3

Alternate Interpretation of the Original Fleischmann and Pons Experiments

MEMS Pressure Sensor Testing at Liquid Helium Temperatures Using a Pressure Bomb

This lab was adapted from Kwantlen University College s Determination of e/m lab.

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

Introduction to Blackbody Sources

A simple calorimetric method to avoid artifacts in a controversial field: the ice calorimeter

Thermal Coatings for In-vacuum Radiation Cooling LIGO-T C R. Abbott, S. Waldman, Caltech 12 March, 2007

A Possible Calorimetric Error in Heavy Water Electrolysis on Platinum (U)

Nuclear reactions produced in an operating electrolysis cell. Abstract

Ratio of Charge to Mass (e/m) for the Electron

PhysicsAndMathsTutor.com

A PRELIMINARY ALIGNMENT PLAN FOR RIA AT MSU

Evidence for Nuclear Reactions in Ni-H Systems I: Heat Excess Measurements

Instruction Manual for EP-20 e/m of the Electron Apparatus

Measurement Artifacts in Gas-loading Experiments

REACTANT HAVING MULTILAYER FILM STRUCTURE FOR GENERATING HEAT FROM REACTION BETWEEN HYDROGEN AND METAL

Simple Harmonic Motion - MBL

SUPER-ABSORPTION CORRELATION BETWEEN DEUTERIUM FLUX AND EXCESS HEAT

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Critical Current Properties of HTS Twisted Stacked-Tape Cable in Subcooled- and Pressurized-Liquid Nitrogen

Ion Beam Sources for Neutral Beam Injectors: studies and design for components active cooling and caesium ovens

Cabrillo College Physics 10L. LAB 8 Magnetism. Read Hewitt Chapter 24

Chapter 1. Blackbody Radiation. Theory

Yasuhiro Iwamura, Takehiko Itoh, Nobuaki Gotoh and Ichiro Toyoda

Photoelectric Effect

Determination of freezing points of pure substances with Cobra4 TEC

Experimental Methods and Analysis

Thermal sensitive foils in physics experiments

CURRENT LEADS FOR THE LHC MAGNET SYSTEM

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

Thermal analysis of superconducting undulator cryomodules

Electro - Principles I

JOURNAL OF CONDENSED MATTER NUCLEAR SCIENCE. Experiments and Methods in Cold Fusion

Evidence of electromagnetic radiation from Ni-H Systems

Calibration of Temperature Block Calibrators

Anomalous Excess Heat by D 2 O/Pd Cell under L-H Mode Electrolysis

Thermodynamics. We can summarize the four laws of thermodynamics as follows:

Experiment B6 Thermal Properties of Materials Procedure

THE PRECURSOR OF "COLD FUSION" PHENOMENON IN DEUTERIUM/ SOLID SYSTEMS

Copyright 2008, University of Chicago, Department of Physics HEAT CAPACITY OF METALS

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Ordinary Level

Morning FOR EXAMINER S USE WRITE YOUR ANSWER TO EACH QUESTION IN THE SPACE PROVIDED. ANSWERS WRITTEN ELSEWHERE WILL NOT BE MARKED.

Thursday 19 June 2014 Morning

IMPROVED ADIABATIC CALORIMETRY IN THE PHI-TEC APPARATUS USING AUTOMATED ON-LINE HEAT LOSS COMPENSATION

Report on Deliverable D 5.5

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.

VHITAL-160 thermal model building and 3D thermal modeling carrying-out

Thermal Capacity Measurement of Engineering Alloys in Dependence on Temperature.

The Measurement of e/m

HSC KICKSTART PHYSICS WORKSHOP

4.1. Physics Module Form 4 Chapter 4 - Heat GCKL UNDERSTANDING THERMAL EQUILIBRIUM. What is thermal equilibrium?

Specific Heat. Power Supply Beaker Beam Balance Conecting wires ice. Assembly

Heat capacity of gases

Specific Heat. Power Supply Beaker Beam Balance Conecting wires ice. Assembly

Semi-Conductors insulators semi-conductors N-type Semi-Conductors P-type Semi-Conductors

Electromagnetism Notes 1 Magnetic Fields

KCSE PHYSICS PAPER SECTION A (25 marks) Answer all the questions in this section in the spaces provided.

Interaction of Hydrogen on a Lanthanum hexaboride (111) Surface Jenna Cameli, Aashani Tillekaratne, Michael Trenary Department of Chemistry,

I. Yang, C. H. Song, Y.-G. Kim & K. S. Gam

Compiled and rearranged by Sajit Chandra Shakya

Chapter 1 The discovery of the electron 1.1 Thermionic emission of electrons

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

Lab 6 - ELECTRON CHARGE-TO-MASS RATIO

HALL EFFECT. In a Ga!ium Arsenide Semiconductor. Jason Robin Fall 07 Phy Adv Lab. Ha! Effect 1

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Project PAJ2 Dynamic Performance of Adhesively Bonded Joints. Report No. 3 August Proposed Draft for the Revision of ISO

Charge to Mass Ratio of The Electron

Physics P201 D. Baxter/R. Heinz. EXAM #3 November 21, :00 9:00 PM INSTRUCTIONS

Coimisiún na Scrúduithe Stáit State Examinations Commission

AE 3051, Lab #16. Investigation of the Ideal Gas State Equation. By: George P. Burdell. Group E3

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

Energy Conversion in the Peltier Device

SEARCH FOR NUCLEAR PHENOMENA BY THE INTERACTION BETWEEN TITANIUM AND DEUTERIUM

Answer all the questions in this section in the spaces provided.

Transcription:

Cerron-Zeballos, E., et al., Investigation of anomalous heat production in Ni-H systems. Nuovo Cimento Soc. Ital. Fis. A, 1996. 109A: p. 1645. Investigation of anomalous heat production in Ni-H systems E. Cerron-Zeballos, I, Crotty, D. Hatzifotiadou, J. Lamas Valverde M. C. S. Williams and A. Zichichi LAA project, CERN - Geneva, Switzerland (ricevuto il 3 Luglio 1996; approvato il 18 Novcmbre 1996) Summary. Anomalous heat production in a nickel rod loaded with hydrogen has been reported by Focardi et al. (Nuovo Cimento A, 107 (1994) 163). We have investigated this phenomenon by repeating the experiment. We found the results previously published to be consistent with our observations; namely we measured higher temperatures for the same input power when hydrogen is absorbed during a heating cycle. Nevertheless this temperature rise does not appear to correspond to an increase in heat production. We have added a temperature sensor to the container of the experiment. The temperature of the container follows the same temperature with input power curve irrespective of whether there is an anomalous absorption of hydrogen or not; therefore we have no evidence that this temperature increase corresponds to another source of heat. In conclusion, we have observed all the effects discovered by Focardi et al., but our results imply that there is no production of power associated with the absorption of hydrogen by nickel PACS 25.70.Jj - Fusion and fusion-fission reactions. 1. - Introduction The anomalous production of heat in various systems has been searched for since the experiment of Fleischmann, Hawkins and Pons [1]. Recently there has been considerable excitement over the results published by Focardi, Habel and Piantelli [2], They reported that after several loading cycles, where they loaded a nickel rod with hydrogen gas, they observed excess heat when the rod was above 178 C. Furthermore they found that this heat imbalance was stable and that they produced 44 W continuously for 24 days (90 MJ total) until they switched the device off. They further commented that they were examining the reaction (p, D) as a candidate for the heat generation reaction, where D is that naturally contained in hydrogen. Let us first consider the fusion of pd, we find the following: pd 3 He + γ (the energy of γ is 10-12 J). Focardi et al. reported that their container was 10 cm long, with 5 cm diameter (i.e. 0.2 l). They filled it to 0.5 A of H 2 ; this is 9 10-6 kg of H 2 i.e. 6 10 21 atoms of H. As 1:6000 H naturally appears as D, there are 10 18 atoms of D. Thus if all the possible D were converted and all the energy captured, we would have 1 MJ available. They reported that they obtained 90 MJ, and the device was still running when it was switched off. Thus the reaction pd appears to be an unlikely candidate. 1

Nonetheless the production of 90 MJ of energy warrants attention. We have repeated their experiment in order to understand the origin of this heat imbalance. 2. - Description of the experimental apparatus We constructed a container from stainless steel pieces, normally used for vacuum systems. The container was 12 cm long, with 8.5 cm diameter. One end was sealed by a flange piece 1 cm thick. We had electrical feed-throughs and various pipe fittings put into this flange. The electrical feed-throughs were to supply the power to the heater coil. One pipe fitting was used to supply gas to the cell (usually hydrogen) while the remainder of the pipe fittings allowed thermocouples, used to measure the temperature at various points, to be connected to the external monitor. The coil was 42 turns of 1 mm thick platinum wire, wound in a 1.8 cm diameter. The coil was held in the centre of the container with three ceramic rods. The rod was of 6 mm diameter nickel, at each end we used a short section of ceramic tube to hold it in place at the centre of the heater coil. At one end of the rod we drilled a 1 mm diameter hole 3 cm deep. Into this hole we pushed a thermocouple temperature sensor until it reached the end. At the other end of the container we had a reduction flange and then a 30 cm long stainless steel flexible tube connected to a vacuum pump and pressure sensor. We used three thermocouple sensors, one inside the nickel rod, one attached to the centre of the platinum coil and one connected to the outside of the container. We also recorded the ambient temperature. Fig. 1. - Cross-section of our experimental set-up. Initially one thermocouple was connected to the end of the coil. At this position often the coil temperature was lower than the rod temperature. We assumed that this was due to the thermal losses, since the ends of the coil were connected to the lower temperature of the container via the electrical connections. We thus attached the thermocouple sensor to the centre of the coil; we believe this position to have the highest coil temperature. A cross-section of the assembly is 2

shown in fig. 1. We mounted the assembly on a bench in our laboratory; cooling was provided by normal air convection. Thus our device consisted of a platinum heater, with a thermocouple attached to the centre of the coil. Located inside this heater we had a nickel rod, with a thermocouple mounted inside the rod. This was mounted inside a stainless steel container which has a thermocouple attached to the outer surface. The container could be pumped out to a vacuum of 10-6 Torr with a turbomolecular pump, or filled with a gas, usually hydrogen, but some cycles have been performed with deuterium and helium. Heat can be supplied to the system by passing a current through the heater coil. We monitored the current and voltage supplied to the heater and thus could measure the power supplied and the resistance of the heater coil. 3. - Loading cycle Our loading cycle was defined as filling the container with 360 Torr hydrogen and ramping the power up and then down. We stepped the power in roughly 25 W steps. We found that after each change of power we had to wait 2 hours or so for thermal equilibrium to be reached. At each step in power, after thermal equilibrium had been reached, we recorded the input power, the pressure, the temperature of the heater coil, the rod and the temperature of the stainless steel container. We measured the pressure of the gas at the end of the loading cycle when the apparatus had regained ambient temperature; if there was a reduction of pressure from the initial value (usually 360 Torr) we defined the cycle as an absorption cycle. If there was an increase in pressure we classified it as a desorption cycle. In fig. 2 we histogram this difference in pressure. Fig. 2. - Histogram of absorption Δp (difference between hydrogen pressure in the beginning and at the end of the cycle at room temperature). 4. - Observation of absorption Focardi et al. do not specify exactly what they consider a loading cycle or at which point in the cycle the hydrogen absorption occurs. In order to understand when the hydrogen is absorbed during the cycle, we monitored carefully the gas pressure inside the cell and the temperature while waiting for thermal equilibrium after each step of power. On some occasions we observed 3

absorption of hydrogen: the gas pressure started to decrease while the temperature of both the coil and the rod increased. In fig. 3 we show the pressure and the temperature of the coil and the rod as a function of time for the first step of power. The initial pressure of hydrogen in the cell was 360 Torr; time 0 is the moment when we applied power of 32 W to the system. The pressure initially rises as does the temperature. However after 5 min, there starts to be a drop in pressure with increasing temperature; this indicates absorption, which started to be obvious at a temperature of 145 C of the coil and 65 C of the rod and stopped at a temperature of 200 C of the coil and 120 C of the rod. The following step in power is also shown in fig. 3; we see that the pressure increases as usual. In this particular cycle there was desorption of hydrogen later in the loading cycle; this cycle was eventually classified as a desorption cycle using the difference of initial and final pressure as described above. Fig. 3. - An anomalous absorption cycle: hydrogen pressure, coil temperature and rod temperature vs. time during the first step in input power (32 W). In fig. 4 we show the temperature of the coil, the rod and the container as a function of the input power for no absorption (Δp = 0 Torr), Δp = 100 Torr and Δp = 13 Torr. For the case of 100 Torr absorption, both the coil and the rod reach higher temperatures than for the no absorption case, for the same values of input power. However the temperature of the container has the same relationship to input power independently of whether there is absorption or not. Prior to this 100 Torr absorption the following procedure had been performed: after a number of heating and cooling cycles, the cell was evacuated, it was then heated for 24 hours to a rod temperature of 500 C and finally left to cool with simultaneous pumping with the turbomolecular pump to obtain a vacuum of 10-6 Torr for 24 hours. Subsequent loading cycles performed after this 100 Torr absorption cycle showed no absorption. We tried to reproduce this absorption phenomenon by repeating the steps that had preceded its observation, namely emptying, heating and pumping to 10-6 Torr with the turbo pump. On occasions we had some smaller absorption or none. 4

Fig. 4. - Coil, rod and container temperature vs. input power for 3 cases (Δp/3 = 0,13 and 100 Torr); coil material is platinum. In the case of absorption there is less gas in the cell than the quantity initially put in; this can change the thermodynamic equilibrium state of the apparatus, and possibly could be the cause of the elevated temperature of the rod and coil. In order to clarify this point we checked the 5

behaviour of the system for different values of initial pressure. Figure 5 shows the temperature of the coil and the rod as a function of the input power, for 173 Torr, 280 Torr, 363 Torr and 500 Torr initial gas pressure. As can be seen there is a small variation of coil or rod temperature with gas pressure within this range. However, for the case when there is 100 Torr absorption one should compare the 3 curves corresponding to 173, 280 and 360 Torr initial pressure; one can easily see that the variation in pressure could explain a variation of several degrees, but the effect (as shown in fig. 4) is of the order of 60 C. Fig. 5. - Coil and rod temperature vs. input power for initial hydrogen pressure 173, 280, 363 and 500 Torr. We cycled this cell for over a year, and tried to trigger loading cycles that had a large absorption using the procedure stated above. However we found that we could not; all cycles had small absorption or desorption and the temperature of the rod and coil had the same relationship to input power as the lower curve in fig. 4. (There may have been some other anomalous absorption cycles at the beginning of the experiment when we were still trying to define what we called a loading cycle). We have opened the apparatus and examined the heater coil and nickel rod. There was a grey deposit on much of the interior due to zinc extracted from various brass 6

pieces used to make various electric connections. The surface of the nickel rod was examined with an electron microscope and compared to nickel rod that had not undergone this experiment. In general, the electron microscope showed that the rod used for the experiment was smoother than the virgin rod; this smoothing could be due to the heating cycles. 5. - Cells 2 and 3 We found that this phenomenon of absorption of hydrogen was not reproducible. We also could not be absolutely sure which component inside our cell was responsible for the absorption. In our effort to understand the absorption of hydrogen, we constructed two more cells similar to the first one, as described in sect. 2, but using different metal combinations. Cell number 2 had a stainless steel heater coil and a nickel rod; cell number 3 had a platinum heater coil and a stainless steel rod. With cells number 2 and 3 we followed the same loading procedure as with cell number 1. Repeated cycles with cell number 2 showed an anomalous absorption cycle similar to that of the first cell. This cycle happened after the same procedure of emptying, heating and pumping to a vacuum of 10-6 Torr as described above. Figure 6 shows a histogram of the absorption (i.e. the difference between initial and final pressure at room temperature for each cycle). The negative values correspond to desorption of hydrogen. Fig. 6. - Histogram of absorption, Δp (difference between hydrogen pressure in the beginning and at the end of the cycle at room temperature) for cell number 2. In fig. 7 we show the temperature of the coil, the rod and the container as a function of the input power for no absorption (Δp = 0 Torr), Δp = 150 Torr and Δp = 30 Torr (for cell number 2). The results are similar to cell number 1; both the coil and the rod reach higher temperatures when there is this anomalous high absorption than for the cycles having small or no absorption. Also, similarly the temperature of the cell container vs. input power for the 3 cases (Δp = 0, 150 and 30 Torr) shows no variation, indicating no excess heat. 7

Fig. 7. - Coil, rod and container temperature vs. input power for 3 cases (Δp = 0, 30 and 150 Torr) for cell number 2. Repeated cycles with cell number 3 have shown no absorption. In fig. 8 we show a histogram of the absorption. We have also tested the behaviour of the cell when we have a vacuum inside. When there is no hydrogen inside the cell, the rod and heater coil reach higher temperatures (several hundred of degrees) than for the case of 380 Torr hydrogen, for the same values of input 8

power. This is similar to the observation of Focardi et al. In addition we monitored the temperature of the container; this showed the same relationship whether there was a vacuum inside the container or whether it was filled with hydrogen. This is in agreement with the observation in cells number 1 and 2, where the temperature of the container is the same whether there is a large (anomalous) absorption or not. Therefore this confirms our belief that there is no excess heat, but only local temperature variations within the cell. Fig. 8. - Histogram of absorption, Δp (difference between hydrogen pressure in the beginning and at the end of the cycle at room temperature) for cell number 3. 6. - Additional tests While trying to understand the absorption of hydrogen, we made other tests. One test was for gas leaks, using a special precision apparatus (which is used for the LEP vacuum beam pipe). This showed no detectable leaks. In addition, we made two cycles with helium during which no absorption was observed, i.e. the helium pressure at the beginning and at the end of the cycle was the same. Of course two cycles is rather low statistics; however it shows that we have a leak-free system, and there is no absorption when we expect no absorption. Finally, we made three cycles with a mixture of 50% deuterium-50% hydrogen. Unfortunately no absorption was observed during these cycles and also there was no temperature deviation from the «standard» curve. 7. Summary and conclusions We have built an apparatus similar to that of Focardi et al. This apparatus has a similar temperature to power relationship to the data published by Focardi et al. We have observed a similar increase in rod and heater coil temperature as reported by Focardi et al. during loading cycles which had an anomalous absorption of hydrogen. However, since we recorded the temperature of the container (Focardi et al. do not mention making such a measurement) we cannot attribute this rise in temperature to an extra source of heat. We believe that the rise in 9

temperature must be due to a change in the thermal characteristics of the nickel bar correlated to the phenomenon of hydrogen absorption. The fact that no absorption has been observed with cell number 3 (stainless steel rod, platinum coil) and that the behaviour of cell number 2 (nickel rod, stainless steel coil) is similar to that of cell number 1 (nickel rod, platinum coil), indicates that it is the nickel rod that is responsible for the absorption of hydrogen. In addition, the phenomenon of hydrogen absorption proves to be non-reproducible from one loading cycle to the next and we have been unable to define the trigger condition that guarantees an anomalous absorption cycle. REFERENCES 1. Focardi S., Hahel R. and Piantelli F., Nuovo Cimento A, 107 (1994) 163. 2. Fleischmann M., Hawkins M. and Pons S., J. Electroanal. Chem., 261 (1989) 301. 10