Graphite Block Acid Digestion System ODLAB

Similar documents
Basic Digestion Principles

Not Just for Paint Chips Anymore. High Throughput, Open Vessel Microwave Digestion of Matrices Requiring Moderate Conditions

Determination the elemental composition of soil samples

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

Test Method: CPSC-CH-E

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

Test Report No. CE/2017/40923 Date 2017/04/14 Page 2 of 5 Test Result(s) PART NAME No.1 COPPER COLORED METAL WIRE Test Item(s) Cadmium (Cd) Lead (Pb)

Prof. Dr. Biljana Škrbić, Jelena Živančev

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

The PinAAcle Family of AAS Features and Benefits

METHOD 3520B CONTINUOUS LIQUID-LIQUID EXTRACTION

Kjeltec 2300 Analyzer Unit

METHOD 3520C CONTINUOUS LIQUID-LIQUID EXTRACTION

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

Consideration of Non-radioactive Harmful Substances

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

UNITED NATIONS. ENVIRONMENT PROGRAMME MEDITERRANEAN ACTION PLAN 25 May 2015 Original: English. UNEP(DEPI)/ MED WG.417/Inf.14

Experiment C-15 Distillation - part 1

OPTIMIZING METALS SAMPLE PREP

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

Test Report No Date : 27/NOV/2017 Page 1 of 5

Solvothermal Technique Guidelines

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

A New Cross-Shaped Graphite Furnace with Ballast Body for Reduction of Interferences in Atomic Absorption Spectrometry

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Test Report No _rev01 Date: 06/DEC/2017 Page 1 of 5

METHOD 3510B SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

Oxygen Demand, Chemical

Leaching of Heavy Metals Contaminants in Recycled Polyethylene Terephthalate Used for Food Packaging

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

á233ñ ELEMENTAL IMPURITIES PROCEDURES

Testing and Calculating. Cannabis. Uncertainty. Analytical Chemistry and Cannabis

ED 701 General Industry Pressure Transmitter

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Cadmium and lead content

Experiment 8: Chlorination of 1-Chlorobutane

Chemistry 212 MOLAR MASS OF A VOLATILE LIQUID USING THE IDEAL GAS LAW

Experiment 17. Synthesis of Aspirin. Introduction

MARS 6 Batch Microwave Acid Digestion System

Sodium Chloride - Analytical Standard

Laboratory 101: A Guide to Understanding your Testing Laboratory

ISA QATAR : 90 th Seminar

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

Approximate Volatile Acids by Titration

Apply the ideal gas law (PV = nrt) to experimentally determine the number of moles of carbon dioxide gas generated

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

ICP-OES Application Note Number 35

Moisture Analyzers.

Sampling. Information is helpful in implementing control measures for reducing pollutant concentration to acceptable levels

Oxygen Demand, Chemical

TEST REPORT. NO.: A001R Date: Dec 27, 2013 Page 1 of 13

Safety in the Chemistry Laboratory

Analog Technologies. High Stability Miniature Thermistor ATH10K0.1%1R25

Mercury Determination in Lichen, BCR-482, Using the QuickTrace M-7600 CVAAS Mercury Analyzer

EXPERIMENT 6 Empirical Formula of a Compound

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Synthesis of Benzoic Acid

Corn Sugar (crude & refined) Analysis F MOISTURE (Karl Fischer)

RESEARCHING THE ABSORPTION OF IONS OF HEAVY METALS ON CLINOPTILOLITH MAC SIMULATION OF PROCEDURES IN MAN'S DIGESTIVE SYSTEM

Citric Acid Analysis L-6-1. MOISTURE (Karl Fischer)

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

METHOD 3665 SULFURIC ACID/PERMANGANATE CLEANUP

H E L P I N G C H E M I S T S. UltraCLAVE. The Next Generation Microwave Digestion System

Method NumberUSTUR 150

Qualitative Analysis I - Cations

PROFICIENCY TESTING: EXPERIENCES FROM CROATIA ON THE ISSUE OF HEAVY METALS DETERMINATION IN MARINE SEDIMENTS

Figure 4-1: Pretreatment schematic

Application Note No. 197/2015 Nitrogen and protein determination in dairy products Nitrogen determination in sodium nitrate

Certificate of Analysis

Evaluation copy. The Molar Mass of a Volatile Liquid. computer OBJECTIVES MATERIALS

Figure 1. Describe how the Law of Conservation of Energy applies to the chemical reaction that occurs in the hot pack

Industrial Hygiene Report

Standards 8.5.c. I know chemical reactions usually liberate or absorbs heat.

Test Report No. : CE/2015/15894 Date : 2015/02/04 NIHON ALMIT CO., LTD. ALMIT BLDG., , YAYOICHO, NAKANO-KU, TOKYO, JAPAN Page : 1 of 7 *CE/2015/

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Eppendorf SmartBlock. Instructions for use

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

Conductive Polymer Capacitors

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

FUNDAMENTAL PARAMETERS ANALYSIS OF ROHS ELEMENTS IN PLASTICS

Warning!! Chapter 5 Gases. Chapter Objectives. Chapter Objectives. Chapter Objectives. Air Pollution

THE VERSATILE VSP2: A TOOL FOR ADIABATIC THERMAL ANALYSIS AND VENT SIZING APPLICATIONS

Press. Allbest Creative Development Ltd. (ALLBEST)

Pressure Measurement Single-range transmitters for general applications

Exp t 144 Synthesis of N,N-Diethyl-m-Toluamide: The Insect Repellent "OFF"

Page 2 of 11 Test Result(s) PART NAME No.1 COPPER/SILVER COLORED METAL SHEET (INCLUDING THE PLATING LAYER) Cadmium (Cd) Test Item(s) Unit Method With

Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy

The Investigation of Fertilizer Analyses Using Microwave Digestion and the Agilent 720-ES

Thermometer Line. today s laboratory and field

The challenges of field sensors for trace metal detection. Chris Searle Product Manager Trace2o Ltd

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

Methods of pollution control and waste management - laboratory. Adsorptive removal of volatile organic compounds from gases streams

2. Synthesis of Aspirin

Dimethylphenol Method Method to mg/l NO 3 N or 1.00 to mg/l NO

Transcription:

Graphite Block Acid Digestion System

Table of contents 1. company introduction and product development background 2. Hot Plate and Graphite Block Acid Digestion and Microwave Digestion comparison 1 2 3 4 5 6 7 8 Heating method Heat plate merits and demerits Graphite block merits and demerits Graphite block vessel selection High purity collection digestion vessel (BaekDu ) Graphite block recovery Microwave merits and demerits Comprehensive review

1. Company Introduction and Product Development Background has been established in August 10, 2008 and has mainly sold accessories used for CRM, AAS, ICP, ICP-MS and sample acid digestion system used for AAS, ICP, ICP-MS. In order to analyze heavy metal within sample by using AAS, ICP, ICP-MS in chemical analyzing room, acid digestion is required for most cases. has complemented existing hot plates and microwaves problems and has developed graphite block acid digestion system and high purity teflon collection digestion vessel and pressure digestion vessel for the first time in the world and has completed patent application internationally and has commercialized products. We strongly recommend our company s graphite block acid digestion system for companies that have not been able to gain accurate data due to hume hood or hot plate corrosion in laboratories due to sample digestion volume restriction, loss, pollution in existing products. CEO Um Young Rok

1Heating method Heat by sheet for hot plate - Sample indirect heating - Heated in the order of hot plate vessel sample Graphite block heats by electric sheet - Sample indirect heating - Heats both bottom and side vessel increasing digestion efficiency than hot plate Heat by microwave sample direct heating - Easily heat sample elements by direct heating - Heat by generating rotation and ion-conductor of dipole within sample

2 Hot Plate merits and demerits Can select diverse vessels (Pressure Vessel, Open Vessel) Loss and pollution of gas elements Frequent breakdown of Hume Hood and Hot plate Low digestion efficiency by only heating bottom Vessel Long Digestion Time

3 Graphite block Digestion merits and demerits Can select diverse vessels (trap vessel, Pressure Vessel, Open) Low gas elements loss and pollution. Digestion by one-time acid injection (digestion by acid recycling) Heat throughout the vessel to increase digestion efficiency Digestion time is shorter compared to heating plate and longer than microwave Extends hume hood use life from harmful gas and protects digestion subjects Prevents sample pollution that can occur during digestion

4 Select vessel from black lead block (can be applied in various vessels) Black leadblock size is tailored made in holes and dimension - Prevents corrosion by using one element black lead (carbon) and coating - Can be applied in various vessels of laboratory as below Teflon pressure digestion vessel, digest for a long time at 130 - Restricts sample volume, pressure digestion, cannot digest excessive organic material - Appropriate to samples that are relatively well digested (relatively less pollution or loss of metal, small volume of soil, small volume of bio gas element ) (fits to ICP-MS) Teflon collection digestion vessel, digest at 260 - Dry sample 2g digestion possible, recycle digestion with sample collection (acid one-time injection) - Gas element collects from collection tube at the upper part of digestion vessel for digestion (internationally patented) - Applied diverse global digestion method for digestion (soil, food, EPA, marine, water etc) Stainless teflon super high pressure digestion vessel, digests at 260 - Digests at 200bar, appropriate for samples difficult to digest - Select diverse vessels from 25ml~250ml for usage - Apply to samples difficult to digest in microwave

5 High purity collection digestion vessel characteristics (High purity Trap Teflon Vessel) Digests at 260 Dry sample 2g digestion possible, sample recycling digestion (digestion completed with one-time acid injection) Gas elements are collected from upper part of collection tube of digestion vessel (Hg and etc) Applied diverse global digestion methods for digestion (Soil Din ISO11466 Method, Korea Food Test, US-EPA3050, IEC62321 etc) When digestion vessel is heated, the acid moves up and down to complete digestion automatically Heat start Vaporization Vaporization peak Fall Revaporiazation

6 Graphite block digestion recovery KRISS butter cup CRM - plant Pb Cd Certificated value 1.05ppm *0.066ppm Sample 1 1.048ppm 0.068ppm Sample 2 1.047ppm 0.067ppm Varian ICP-MS, Clean room, super high purity nitro acidacid 14ml * table is reference value JSAC plastic High level CRM - Plastic Pb Cd Cr Certificated value 945ppm 93.6ppm 946.3ppm Sample 1 957.4ppm 88.6ppm 902ppm Sample 2 925.8ppm 89.7ppm 897.3ppm Perkin Elmer ICP, nitro acid 15ml, hydrogen peroxide 2ml, sulfuric acid 2ml

7Mircowave digestion merits and demerits Passes through vessel Absorbs sample Gas Vapor Liquid Digestion vessel PTFE (heavy metal attachment) sample pollution and loss Microwave injection Restriction on sample digestion volume (explosion danger exists) Suitable for samples difficult to digest Good digestion efficiency with pressure digestion and short digestion time

Microwave merits and demerits Quick digestion time 60 minutes (cooling time separate) Digestion by temperature and pressure sensor High pressure digestion possible by closed vessel Can digest samples difficult to digest Can control pressure and temperature of each vessel Inappropriate for samples requiring more than 0.5g of sample volume (explosion) Inconvenience in vessel assembly Inconvenience in cleaning By using pores PTFE teflon loss and pollution due to heavy metal attachment (mercury etc) Recently possibility of gas element loss by using pressure emitting teflon vessel Explosion danger system price, maintenance cost Cannot view the digestion process of sample

8 Comprehensive Review Hot Plate Graphite block Microwave Pressure digestion Digestion time Sample treatment Applied diverse digestion method Recovery Price Volatile element Collection digestion Air pressure More than 1h Significant Impossible bad Very low impossible impossible Possible (low pressure) 1h ~3h Max 24 Possible good Mid price Possible possible Possible 1h30 8 or 16 or 40 Possible Good High possible(close) possible (close *Digestion time differs by sample volume. The above time is based on approximately 0.5g