Acclaim HPLC and UHPLC Columns

Similar documents
Acclaim HPLC and UHPLC Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Thermo Scientific Acclaim. Catalogue 9. Hichrom Limited

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode HILIC-1 Column

Analysis - HPLC A.136. Primesep 5 µm columns B.136

penta-hilic UHPLC COLUMNS

Packings for HPLC. Packings for HPLC

penta-hilic UHPLC COLUMNS

Acclaim HILIC-10 Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

Acclaim Mixed-Mode WAX-1 Columns

Alltech Alltima HP Introduction

for Acclaim Trinity TM P1

LC and LC/MS Column Selection Flow Chart

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

LC Technical Information

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

8. Methods in Developing Mobile Phase Condition for C18 Column

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

LC Columns with Liquid Separation Cell Technology

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Comparison of different aqueous mobile phase HPLC techniques

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Optimisil HPLC & UPLC Column catalogue

Hypersil BDS Columns TG 01-05

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns

Advantages of polymerbased. an alternative for ODS

HPLC Column Selection: Solve the Separation Mystery. The world leader in serving science

Method Development Kits

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Dionex IonPac AS28-Fast-4µm column

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

Application Specific HPLC and UHPLC Columns

Cation Exchange HPLC Columns

UPLC Method Development and Validation

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Technical Guide Thermo Scientific Syncronis HPLC Columns

Reversed Phase Solvents

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

InertSustainSwift C8

Shodex TM ODP2 HP series columns

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Fluophase and Fluofix Columns

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Thermo Scientific Acclaim Surfactant Plus Column

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Small Molecule Selectivity Sampler

It s hot! ZIC -chilic

New Developments in Surfactant Analysis Using HPLC

Analyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column

Epic Aromatic Selectivity

groups I and II cations, amines, divalent transition metals

Part 2. Overview of HPLC Media

Changing the way you think about HPLC

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Sepax SRT -C, Zenix -C SEC Phases

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

C18 Column. Care & Use Sheet

Passion. Power. Productivity.

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

The Role of the Carbon Cartridge in the One-Pass System

columns IonPac AS17-C Anion Exchange Column

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

mau 200 ph min

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N )

How proteins separate on reverse-phase HPLC

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

Too Polar for Reversed Phase What Do You Do?

Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger

The Evolving HPLC Column Packings

Transcription:

Acclaim HPLC and UHPLC Columns Optimal selectivity through innovative chemistries Designed for separating a variety of analytes, from small neutral and polar molecules to complex mixtures. Ideal for pharmaceutical, environmental, food and beverage and chemical applications. Novel and proprietary surface chemistries Strict manufacturing and quality processes O OH O For optimum resolution of complex mixtures O Thermo Scientific Chromatography Columns and Consumables 6-7 Spherical Silica Providing consistent quality and performance The Acclaim web page contains the latest news, applications and downloads for the Acclaim HPLC column range. Visit www.thermoscientific.com/acclaim -

6 mau Acclaim C8 performance reversed-phase columns for reproducible results hydrophobic retention Excellent efficiencies for maximum resolution silanol activity for excellent peak shapes for basic analytes Extremely low bleed, fully compatible with MS The Acclaim columns are designed for high resolution reversed-phase separations. The very high surface coverage and very low metal content together result in columns with excellent efficiencies. These columns provide exceptional performance for a variety of applications in the pharmaceutical, chemical, environmental and food separations areas. A Standard Column 5 6 5 B RSLC Column 6 Acceleration 6 8 C Double Velocity Acceleration 5 to 8 Å Carbon Load (%) 8 5 Particle Size.μm, μm, 5μm USP L A: Acclaim C8, 5µm, 5 x.6mm B, C: Acclaim RSLC C8,.µm, 5 x.mm Mobile Phase: mm HOAc in % (v/v) MeOH Temperature: C Flow Rate: A:.mL/min B:.mL/min C:.8mL/min Injection Volume: A: µl B:.µL C:.µL Detection: UV, 5 nm, A: Hz data rate B: 5 Hz data rate C: Hz data rate Analytes:. p-hydroxybenzoic acid. p-hydroxybenzaldehyde. Vanillic acid. Vanillin Sample: Commercial vanilla extract in % ethanol, filtered Reference: AOAC Official Method 99.5 LC Columns and Accessories >> Acclaim Acclaim C8 Particle Size (µm) Format Length (mm).mm ID.mm ID.6mm ID. RSLC Column 7 766-5 6898 765-75 - 75697-6898 76-5 799 - - 5 78 - - HPLC Column - 667-5 598 6897 59 75-667 - 599 7686 59 5 59 669 59 5 7687 777-5 Guard Cartridge 69689 798 69695 HPLC Column 5 - - 598 5 - - 599 See page -7 for Acclaim Guard Holder Ordering Guide www.thermoscientific.com/chromatography -5

Acclaim C8 performance reversed-phase columns with intermediate hydrophobic retention silanol activity for excellent peak shapes for basic analytes Excellent column efficiencies LC-MS compatible Acclaim C8 reversed-phase columns feature densely bonded monolayer C8 ligands on a high-purity, spherical porous silica substrate. The columns are a well-characterized line of LC-MS compatible C8 phases with very high surface coverage and extremely low silanol activity. These columns provide exceptional performance for a variety of applications in the pharmaceutical, environmental, food and many other industrial sectors. to 8 Å Carbon Load (%) 5 Particle Size.μm, μm, 5μm USP L7 mau Triclosan in toothpaste 8 8. nm Mobile Phase: Isocratic, 5% buffer, (mm Ammonium acetate ph5), 85% methanol (v/v) Temperature: 5 C Flow Rate:.mL/min Injection Volume:.µL Detection: Diode array detector, 8nm, Hz,. s resp. time and spectra nm Analytes:. Saccharin. Triclosan Sample: Toothpaste containing.% triclosan.... Thermo Scientific Chromatography Columns and Consumables 6-7 Acclaim C8 Particle Size (µm) Format Length (mm).mm ID.mm ID.6mm ID. RSLC Column - 768-5 765 769-766 76-5 767 - - 5 78 - - HPLC Column 5 59-595 59-596 5 59 6897 597 5 7685 - - 5 Guard Cartridge 69688 7979 69696 HPLC Column 5 59-598 - - 599 See page -7 for Acclaim Guard Holder Ordering Guide 5 596-59 5 - - 59-6

Acclaim Phenyl- A unique reversed-phase column with high aromatic selectivity aromatic selectivity hydrophobic retention Unique and complementary selectivity compared to any other phenyl type column Compatibility with highly aqueous mobile phase efficiency and rugged packing Acclaim Phenyl- has a higher pi-pi interaction than other phenyl phases and provides unique selectivity for aromatic compounds while maintaining sufficient hydrophobic interaction and aqueous compatibility for superior chromatographic performance. The Acclaim Phenyl- column can be used in a wide range of applications in pharmaceutical, environmental, food testing and product-quality testing. This column is ideally suited for the analysis of aromatic analytes; some examples include glucocorticosteroids, estrogens, fat-soluble vitamins and phospholipids. to 8 Å Carbon Load (%) 5 Particle Size µm, 5µm USP L LC Columns and Accessories >> Acclaim 6 mau 5 6 9 8 7 6 8 Mobile Phase: Methanol/water v/v 9/ Temperature: C Flow Rate:.5mL/min Injection Volume: μl Detection: UV, nm Analytes: ( ppm each). Retinol acetate (vitamin A acetate). Vitamin D. Vitamin D. delta-tocopherol 5. gamma-tocopherol 6. alpha-tocopherol (vitamin E) 7. Impurity (unknown) 8. Vitamin E acetate 9. Vitamin K. Vitamin K Acclaim Phenyl- Particle Size (µm) Format Length (mm).mm ID.mm ID.6mm ID Guard Cartridge 799 797 797 HPLC Column 5 797 797 7969 5 HPLC Column 5 - - 886 5 - - 79697 Acclaim Guard Holder Format Acclaim Guard Cartridge Holder V- 6958 Acclaim Guard Kit (Holder and Coupler) V- 6977 Guard to Analytical Column Coupler V- 788 www.thermoscientific.com/chromatography -7

Acclaim C Columns for separating structurally related isomers shape selectivity Unique selectivity complementary to other reversed-phase columns Compatibility with highly aqueous mobile phase -quality: low column bleed, high efficiency and rugged packing The Acclaim C is designed to provide high shape selectivity for separating hydrophobic structural related isomers and unique selectivity complementary to other reversed-phase columns (e.g. C8). to 8 Å Carbon Load (%) 5 Particle Size µm, 5µm USP L6 pa A B 6 ng Area 9 LLA 5 6 7 8 9 6 8 Mobile Phase A: Water:formic acid:mobile phase B 9:.6: (v/v) Mobile Phase B: Acetone:acetonitrile:THF:formic acid 675:5::(v/v) Gradient: Time (min) %A %B 6 7 5 95 5 95 9 Temperature: C Flow Rate:.mL/min Injection Volume: µl Detection: Corona ultra, nebulizer 5 C, filter high Analytes:. SDA. EPA. ALA. GLA 5. DHA 6. Arach. 7. LLA Samples: A. Standards in isopropanol B. Saponified chicken fat Thermo Scientific Chromatography Columns and Consumables 6-7 Acclaim C Particle Size (µm) Format Length (mm).mm ID.mm ID.6mm ID HPLC Column 5 78666-7866 78665 - - 5 7575 757 757 5 7866 7576-5 Guard Cartridge 757 757 757 Acclaim Guard Holder Format HPLC Column 5 - - 7579 5 - - 7578 Acclaim Guard Cartridge Holder V- 6958 Acclaim Guard Kit (Holder and Coupler) V- 6977 Guard to Analytical Column Coupler V- 788-8

Acclaim PolarAdvantage Novel polar-embedded reversed-phase columns with unique selectivity Selectivity complementary to the C8 column silanol activity for excellent peak shape with basic compounds Compatible with % aqueous mobile phase selectivity for hydrophobic aromatic molecules Wide range of applications Acclaim PolarAdvantage (PA) columns feature a patented bonding column chemistry that incorporates a polar sulfonamide group with an ether linkage near the silica surface. This unique chemistry provides low silanol activity, compatibility with % aqueous mobile phase. The Acclaim PA column offers great separation power to resolve a wide variety of polar and non-polar analytes and supports LC-MS analysis. EPA 6 phenols 6 mau 5 6 7 8 9.5..5..5. Mobile Phase A: mm formic acid + mm ammonium formate, ph.75 ±.5 Mobile Phase B: Acetonitrile Gradient: -.5...6. %A 7 7 7 %B 9 9 Temperature: C Flow Rate:.5mL/min Injection Volume:.5μL Detection: UV, 8nm, Hz,.5s resp. time Analytes:. Phenol.,-Dinitrophenol. -Nitrophenol. -Chlorophenol 5. -Nitrophenol 6.,-Dimethylphenol 7.,6-Dinitro--methylphenol 8. -Chloro--methylphenol 9.,-Dichlorophenol.,,6-Trichlorophenol. Pentachlorophenol Sample: Calibration mix, 5μg/mL in water to 8 Å Carbon Load (%) 6 5 Particle Size.μm, μm, 5μm USP L6 LC Columns and Accessories >> Acclaim Acclaim PolarAdvantage Particle Size (µm) Format Length (mm).mm ID.mm ID.6mm ID. RSLC Column 5 76 - - 75-75698 - 76 767-5 76 - - 5 78 - - HPLC Column 5 67 6897-66 76-5 67 669 68 5-779 - 5 Guard Cartridge 6969 798 69698 HPLC Column 5 - - 69 5 - - 6 5 - - 6 www.thermoscientific.com/chromatography -9

Acclaim PolarAdvantage II Complementary selectivity and enhanced hydrolytic stability Unique selectivity complementary to the C8 column Novel polar-embedded column chemistry for hydrolytic stability Compatible with % aqueous mobile phase bleed for MS compatibility Wide range of applications Acclaim PolarAdvantage II (PA) columns feature a patented surface chemistry that incorporates an amide-embedded polar group and multi-point attachment between the ligands and the silica surface. This unique chemistry provides enhanced hydrolytic stability from ph.5- with % aqueous mobile phases and exhibits high reversed-phase capacity, with selectivity complementary to conventional C8 columns. The Acclaim PA column is specifically designed to withstand high ph conditions, making it a good choice for the separation of both basic and acidic analytes..5 Carbon Load (%) Å 6 5 Particle Size.μm, μm, 5μm USP L6 Turmeric,, mau C8 Area: 9.7 mau*min. Total area: 9.9 mau*min. PA Mobile Phase A: 5mM H PO Mobile Phase B: Methanol Isocratic: C8: 7% B (v/v) PA: 8% B (v/v) Temperature: C Flow Rate:.mL/min Detection: UV, 8nm Analytes:. Curcumin. Demethoxycurcumin. Bis-demethoxycurcumin Sample: Turmeric extract Thermo Scientific Chromatography Columns and Consumables 6-7 Acclaim PolarAdvantage II Particle Size (µm) Format Length (mm).mm ID.mm ID.6mm ID. RSLC Column 7 769-5 68989 768-6899 767-5 7 - - 5 78 - - HPLC Column - 6676-5 77999 6897 689 75-6677 - 77998 78 78 5 687 675 69 5 77997 78-5 Guard Cartridge 6969 7985 69699 HPLC Column 5 - - 697 See page -7 for Acclaim Guard Holder Ordering Guide 5 - - 699 -

pa Acclaim HILIC- Designed with unique selectivity for hydrophilic molecules Retains highly polar molecules that are not retained by reversed-phase chromatography Unique selectivity, complementary to reversed-phase columns Hydrolytically stable Rugged column packing Broad application range The Acclaim HILIC- column is designed for separating highly hydrophilic molecules by Hydrophilic Interaction Liquid Chromatography (HILIC). This column is based on high-purity spherical porous silica covalently modified with a proprietary hydrophilic layer. Glycerides 5 6 7 8 Mobile Phase A: Heptane Mobile Phase B: -Propanol/acetic acid 99.5:.5 Temperature: 5 C Flow Rate:.5mL/min Injection Volume: μl Detection: Corona ultra, nebulizer 5 C Analytes:. Tristearin. Trilaurin. Distearin isomer. Dilaurin isomer 5. Distearin isomer 6. Dilaurin isomer 7. Monostearin 8. Monolaurin to 8 Å Particle Size µm, 5µm LC Columns and Accessories >> Acclaim 6 8 Acclaim HILIC- Particle Size (µm) Format Length (mm).mm ID.mm ID.6mm ID HPLC Column 5 759 758 757 5 Guard Cartridge 76 76 76 Acclaim Guard Holder Format Acclaim Guard Cartridge Holder V- 6958 Acclaim Guard Kit (Holder and Coupler) V- 6977 Guard to Analytical Column Coupler V- 788 www.thermoscientific.com/chromatography -

Acclaim Mixed-Mode HILIC- Uniquely designed for both reversed-phase and HILIC operations Can operate in both RP and HILIC modes Retains highly polar molecules Unique selectivity complementary to RP columns Broader application range compared with conventional diol-based columns -efficiency column for high-resolution separations The Acclaim Mixed-Mode HILIC- column features a unique, high-efficiency, silica-based HPLC mixed-mode stationary phase that combines both reversed-phase (RP) and hydrophilic interaction liquid chromatography (HILIC) properties. This combination allows both hydrophobic and hydrophilic interactions to be utilized to optimize separations. The functional group is of a hydrophobic alkyl chain with a diol group at the terminus. This unique combination results in the adjustable selectivity, making Acclaim Mixed-Mode HILIC- separate mixtures that would be impossible for a C8 column. This column is suitable for a broad range of applications, including non-ionic ethoxylated surfactants, drug metabolites, lipids, polyethylene glycols (PEGs), ethoxylated surfactants, and more..5 to 7.5 Å Particle Size µm, 5µm Cytosine and naphthalene AU Reversed-Phase Mode HILIC Mode Mobile Phase: CH CN/. M NH OAc, ph 5. v/v 5/8 for RP mode v/v 9/8 for HILIC mode Temperature: C Flow Rate: ml/min Injection Volume: μl Detection: UV, 5nm Analytes:. Cytosine ( ppm). Naphthalene ( ppm) 6 8 Thermo Scientific Chromatography Columns and Consumables 6-7 Particle Size (µm) Format Length (mm).mm ID.mm ID.6mm ID HPLC Column 5-79 - 5 79 79-5 Guard Cartridge 6969 79 6976 HPLC Column 5 6687-668 5 - - 668 Acclaim Guard Holder Format Acclaim Guard Cartridge Holder V- 6958 Acclaim Guard Kit (Holder and Coupler) V- 6977 Guard to Analytical Column Coupler V- 788 -

Acclaim Mixed-Mode WAX- Designed for separating anionic molecules with powerful adjustable selectivity control Adjustable selectivity Selectivity orthogonal to reversed-phase (RP) columns Ideal selectivity for anionic molecules Excellent column efficiency and peak asymmetry Multimode retention mechanisms: reversed-phase, weak anion exchange, and HILIC modes The Acclaim Mixed-Mode WAX- is a novel, high-efficiency silica HPLC column that combines hydrophobic and weak anion exchange characteristics. Its unique chemistry results in a multimode separation mechanism that includes reversed-phase, anion exchange, and HILIC interactions. Selectivity can be adjusted by changing ionic strength, ph or organic solvent content. AU O OH OH Mobile Phase: /6 v/v Acetonitrile/buffer (6.8 g potassium monophosphate and.5 g pyrophosphate in g D.I. H O, ph is adjusted to 6. with NaOH) Temperature: C Flow Rate: ml/min Injection Volume: μl Detection: UV, nm Analytes:. Caffeine. Acetaminophen. Salicylamide. Acetyl salicylic acid (Aspirin) 5. Salicylic acid.5 to 7.5 Å Particle Size µm, 5µm USP L78 LC Columns and Accessories >> Acclaim 5 Particle Size (µm) Format Length (mm).mm ID.mm ID.6mm ID HPLC Column 5-798 - 5 789 788-5 Guard Cartridge 69686 799 697 HPLC Column 5 678-698 5 - - 6985 Acclaim Guard Holder Format Acclaim Guard Cartridge Holder V- 6958 Acclaim Guard Kit (Holder and Coupler) V- 6977 Guard to Analytical Column Coupler V- 788 www.thermoscientific.com/chromatography -

Acclaim Mixed-Mode WCX- Designed for separating cationic molecules with adjustable selectivity control Adjustable selectivity Ideal selectivity for separating basic molecules Selectivity complementary to C8 RP columns Multimode separation mechanism: reversed-phase, weak cation exchange, anion-exclusion and HILIC The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column, with a proprietary ligand with both hydrophobic and weak cation exchange properties. Selectivity of ionizable and neutral compounds can be controlled independently or simultaneously by tuning mobile phase ionic strength, ph or organic modifier. This column therefore can separate using multiple separation modes: reversed-phase, cation exchange, and normal-phase/ HILIC and is recommended for a variety of industrial applications, including pharmaceutical, chemical, consumer products, foods and beverages..5 to 7.5 Å Particle Size µm, 5µm USP L78 Pharmaceutical counterions AU 5 6 7 Mobile Phase: /6 v/v CH CN/NH OAc, ph 5. ( mm total) Temperature: C Flow Rate: ml/min Injection Volume: 5µL Detection: UV (5 nm) Analytes:. Maleate 5μg/mL. Ketoprofen μg/ml. Naproxen μg/ml. Hydrocortisone 6μg/mL 5. Dexamethasone 6μg/mL 6. Oxprenolol μg/ml 7. Timolol 5μg/mL 8 Thermo Scientific Chromatography Columns and Consumables 6-7 Particle Size (µm) Format Length (mm).mm ID.mm ID.6mm ID HPLC Column 5-79 - 5 79 79-5 Guard Cartridge 8555 79 6975 HPLC Column 5 687-685 5 - - 685 Acclaim Guard Holder Format Acclaim Guard Cartridge Holder V- 6958 Acclaim Guard Kit (Holder and Coupler) V- 6977 Guard to Analytical Column Coupler V- 788 -

OmniPac DVB polymer columns for combined ion exchange and reversed-phase separations Acid, base and solvent compatible, ph to Ideal for the separation of high molecular weight organic acids Delivers optimal separation of very hydrophobic anions Delivers optimal separation of halogenated anions Provides simultaneous separation of neutral and ionic species Unique selectivity for polar and ionic organic analytes Delivers optimal separation of organic, hydrophobic, and halogenated cations Thermo Scientific OmniPac is a range of latex-based columns. Both PAX columns have an ion exchange capacity of about μeq per column, and the PCX columns have a capacity of approximately μeq per column. The PAX-5 and PCX-5 columns separate analytes through both ion exchange and reversed-phase mechanisms, due to their higher reversedphase capacity relative to the PAX- and PCX- columns.,5 6,7 8 9 5 5 6 5 7 Mobile Phase: Acetonitrile/Sodium Chloride/ Hydrochloric Acid Gradient Flow Rate:.mL/min Detection: UV, 5nm Analytes:. Orotic Acid. -Hydroxybenzamide. Luminol Impurity. Luminol 5. Pyridine 6. PABA 7., -Bipyridine 8. p-phenylenediamine 9. Naphthylamine. Nitrobenzoic Acid. Tribenzylamine. p-nitroaniline.,-dinitroaniline. Dibenzylamine 5. N-Methyl-N-nitrosoaniline 6. -Chloro--nitroaniline 7.,6-Dichloro--nitroaniline 6Å Å 5 PAX- PAX-5 PCX- PCX-5 LC Columns and Accessories >> OmniPac Description Porosity Length (mm).mm ID PAX- Microporous 5 5 5 5 PAX-5 Microporous 5 5 5 5 Description Porosity Length (mm).mm ID PCX- Microporous 5 9 5 89 PCX-5 Microporous 5 95 5 9 www.thermoscientific.com/chromatography -5

Acclaim Size Exclusion Chromatography (SEC) performance SEC columns for analysis of water soluble polymers Proprietary mono-dispersed multi-pore hydrophilic resin: no inflection points in calibration curve SEC- calibrated from to 5, Daltons SEC- calibrated from, to,, Daltons Availability of small particle sizes packed in x.6mm dimension allows for high-resolution analysis at reduced solvent consumption Stable surface bonding with low column bleed and compatibility with UV, RI, MS, ELSD and Thermo Scientific Dionex Corona Charged Aerosol Detectors Thermo Scientific Acclaim SEC- and SEC- are a family of resin based, high performance size exclusion chromatography columns specifically designed for the separation of water soluble polymers and oligomers. Å (SEC ) Particle Size 5, 7µm to Å (SEC ) 5,, Molecular Weight (Da),,,,,, SEC- SEC- Mobile Phase: mm sodium perchlorate Temperature: 5 C Flow Rate:.5mL/min Injection Volume: 5μL Detection: RI Analytes: (.% -.% in mobile phase) dextran (MW 5,,-,,), PEO (MW 895,, 58,, 7,, 85,, 8,,,, and,), PEG (MW 8,,,,,5, 6, and ), diethylene glycol (MW 6 and ethylene glycol (MW 6).5..5..5..5 Elution Volume (ml) Thermo Scientific Chromatography Columns and Consumables 6-7 -6.5 pa -. PAA µg/l µg/l µg/l 5 µg/l 5 µg/l 5 5.5. Polyacrylic acid Area [ pa *min] Concentration [ µg/l].c 5 5 75 5 Mobile Phase A: Acetonitrile Mobile Phase B: Water Temperature: C Flow Rate:.5mL/min Injection Volume: 5µL Detection: Corona III; evaporator 55 C, Engine C, Hz, filter 5, power function. Analytes:. PAA standards in water Description Particle Size (µm) Format Length (mm).6mm ID 7.8mm ID Acclaim SEC- 5 Guard 87 HPLC Column 5 7976 797 7975 Acclaim SEC- 7 Guard 879 HPLC Column 5 797 797 797