Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR-MS)

Similar documents
Types of Analyzers: Quadrupole: mass filter -part1

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

Week 5: Fourier Tranform-based Mass Analyzers: FT-ICR and Orbitrap

Mass Spectrometry and Proteomics - Lecture 2 - Matthias Trost Newcastle University

Chemistry Instrumental Analysis Lecture 35. Chem 4631

Mass Analyzers. Ion Trap, FTICR, Orbitrap. CU- Boulder CHEM 5181: Mass Spectrometry & Chromatography. Prof. Jose-Luis Jimenez

This is the total charge on an ion divided by the elementary charge (e).

Ion traps. Quadrupole (3D) traps. Linear traps

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. MAGLAB Summer School Ryan P. Rodgers

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Mass Spectrometry. What is Mass Spectrometry?

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

VIII. QUADRUPOLE ION TRAPS: AN ION TRAPPING INST. A. BASIC DESIGN (REF: JMS, 1997, 32, 351)

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

MS/MS .LQGVRI0606([SHULPHQWV

CEE 772: Instrumental Methods in Environmental Analysis

Atomic masses. Atomic masses of elements. Atomic masses of isotopes. Nominal and exact atomic masses. Example: CO, N 2 ja C 2 H 4

GRADUATE COURSE IN MASS SPECTROMETRY: LECTURE 2

Introduction to the Q Trap LC/MS/MS System

LECTURE-11. Hybrid MS Configurations HANDOUT. As discussed in our previous lecture, mass spectrometry is by far the most versatile

arxiv:physics/ v1 [physics.plasm-ph] 5 Nov 2004

Ion trap. 3D Quadrupole Trap. -Mass spectrometer -Ion trap (Quadrupol Ion Storage, Quistor) 18. April

Harris: Quantitative Chemical Analysis, Eight Edition

Tendenze nell innovazione della strumentazione in spettrometria di massa:

Autoresonant Ion Trap Mass Spectrometer The RGA Alternative

1. The range of frequencies that a measurement is sensitive to is called the frequency

Mass Spectrometry in MCAL

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

3. Synchrotrons. Synchrotron Basics

Penning Traps. Contents. Plasma Physics Penning Traps AJW August 16, Introduction. Clasical picture. Radiation Damping.

CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS

TANDEM MASS SPECTROSCOPY

Introduction Introduction

MS Goals and Applications. MS Goals and Applications

Ion motion in a mass analyzer (cell) of a Fourier transform

Lecture 8: Mass Spectrometry

Lecture 8: Mass Spectrometry

THEORETICAL COMPETITION. 1A. SPRING CYLINDER WITH MASSIVE PISTON (5 points)

FOURIER TRANSFORM ION CYCLOTRON RESONANCE MASS SPECTROMETRY: A PRIMER

Translational Biomarker Core

The Aerosol Ion Trap Mass Spectrometer (AIMS): Instrument development and first experimental results

Collision Cross Section: Ideal elastic hard sphere collision:

Quadrupole Storage Mass Spectrometry

1. Historical perspective

Chemistry 311: Topic 3 - Mass Spectrometry

ICPMS Doherty Lecture 1

Section 4 : Accelerators

Secondary Ion Mass Spectroscopy (SIMS)

MS Goals and Applications. MS Goals and Applications

Observing a single hydrogen-like ion in a Penning trap at T = 4K

MARKING SCHEME SET 55/1/MT Q. No. Expected Answer / Value Points Marks Total Marks. Section A

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Physics 6b Winter 2015 Final Campagnari Section Test Form D

Physics 6b Winter 2015 Final Campagnari Section Test Form A

Mass spectrometry gas phase transfer and instrumentation

Class XII Physics (Theory)

Thermo Finnigan LTQ. Specifications

AP Physics C Mechanics Objectives

PARTICLE ACCELERATORS

1) Introduction. 2) Types of Mass Analyzers - Overview. Assigned Reading: Nier mass spectrometry paper Extra Reading:

1P22/1P92 Exam Review Problems 2013 Friday, January 14, :03 AM. Chapter 20

Extrel Application Note

MASS SPECTROMETRY. Topics

Magnetic fields. The symbol we use for a magnetic field is B. The unit is the tesla (T). The Earth s magnetic field is about 5 x 10-5 T.

Time-of-Flight Mass Analyzers

Powerful Scan Modes of QTRAP System Technology

g E. An object whose weight on 6 Earth is 5.0 N is dropped from rest above the Moon s surface. What is its momentum after falling for 3.0s?

Interazioni di ioni con elettroni (ECD, ETD) e fotoni (Ion spectroscopy) Gianluca Giorgi. via Aldo Moro Siena

Formation of High-b ECH Plasma and Inward Particle Diffusion in RT-1

KCET PHYSICS 2014 Version Code: C-2

Photoelectron Spectroscopy using High Order Harmonic Generation

The development of algebraic methods to compute

PH2200 Practice Final Exam Summer 2003

What is Tandem Mass Spectrometry? (MS/MS)

ATHENA / AD-1. First production and detection of cold antihydrogen atoms. ATHENA Collaboration. Rolf Landua CERN

AQA Chemistry A-Level : Atomic Structure

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

CHAPTER D3 TOF ION OPTICS

Space Charge Effects in Linear. Quadrupole Ion Traps

Engines of Discovery

KE = 1 2 mv2 = ev. (1)

Particle physics experiments

Physics 126 Fall 2004 Practice Exam 1. Answer will be posted about Oct. 5.

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

Mass spectrometry: forming ions, to identifying proteins and their modifications Stephen Barnes, PhD

Supporting Information - Polymer analysis in the second dimension: preliminary studies for the characterisation of polymers with 2D MS

Skoog/Holler/Crouch Chapter 19 Principles of Instrumental Analysis, 6th ed. CHAPTER 19

Introduction to Longitudinal Beam Dynamics

Appendices 193 APPENDIX B SCATTERING EXPERIMENTS

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

MARKING SCHEME SET 55/1/RU Q. No. Expected Answer / Value Points Marks Total Marks

Generation and active control of coherent structures in partially neutralized magnetized plasmas

Introduction to MRI. Spin & Magnetic Moments. Relaxation (T1, T2) Spin Echoes. 2DFT Imaging. K-space & Spatial Resolution.

Laser Dissociation of Protonated PAHs

AP Physics Electromagnetic Wrap Up

Weak focusing I. mv r. Only on the reference orbit is zero

ACCELERATION, DECELERATION AND BUNCHING OF STORED AND COOLED ION BEAMS AT THE TSR, HEIDELBERG

Transcription:

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR-MS) The first steps along the way to FT- ICR-MS date back to the 1930s, when Ernest Lawrence, at the University of California - Berkeley, developed the theory of cyclotron resonance, i.e. the acceleration of charged particles inside a cyclotron, that had been invented by himself in 1924. Other milestones in the FT-ICR-MS history are: 1950, Sommer et al., incorporation of ICR principle into a mass spectrometer, the Omegatron 1978, Comisarow and Marshall, adaptation of Fourier Transform methods to ICR spectrometry and development of the first FT-MS instrument

ICR cell The heart of a FT-ICR-MS instrumentation is the ICR cell, an ion trap located within a spatially uniform, static magnetic field of intensity B. Two geometries have been commonly explored for ICR cells, cubic and cylindrical open-ended : The arrow indicates the direction and verse of the magnetic field. Ions can enter the ICR cells either through a hole in a cube face or through one of the open surfaces in the cylindrical cell.

The cubic ICR cell actually derives from the spatial arrangement of six metal square plates, that can be divided into three groups: trapping plates: perpendicular to the magnetic field; one of them has a hole to allow ion injection into the cell; excitation plates: parallel to the B vector plane and normal to the trapping plates; a RF Voltage is applied to these plate during ICR operation; detector plates: normal to the other plate couples; they collect the time dependent signal from which a mass spectrum is subsequently obtained.

In the cylindrical ICR cell: the trapping plates correspond to the two metal cylinders at the ends; trapping plates the excitation and detector plates are four identical cylindrical sectors, arranged into the center section in an alternate configuration: excitation plate detection plate The shape and dimension of the cylindrical cell make it more suitable to fit into the bore of a superconducting magnet, while the cubic cell is better matched with the narrow gap between the pole caps of an electromagnet.

When entering the ICR cell, if no electric field is applied, an ion is subjected only to the Lorentz force due to the magnetic field: Cyclotronic ion motion The force is a vector normal both to the magnetic field (pointing downwards in the figure) and to the ion velocity vector, thus the ion moves along a circular trajectory. Actually, the same phenomenon occurs on any charged particle, including electrons, as shown in the picture on the right, referred to the motion of electrons in a gas-filled bulb put in a magnetic field. The electron trajectory is visible due to gas excitation:

If no external perturbation occurs the cyclotronic motion is periodic and characterized by a cyclotron frequency, depending on B and on the m/z ratio. Since the Lorentz and the centrifugal force related to the cyclotronic motion are equal, the following equation can be written (after renaming the charge as z): since the angular velocity c (rad/s) can be expressed as v/r, the following equation can also be obtained: Finally, the cyclotron frequency can be easily calculated:

The m/z ratio of an ion can be then measured if the frequency of its cyclotronic motion and the magnetic field module are known: A peculiarity of the above relationship is that the value obtained for the m/z ratio of an ion is not influenced by its initial velocity, a unique feature of ICR-MS. Ion kinetic energy spreading cannot influence mass resolution in this case; this explains why ICR-MS can reach ultra-high resolving powers (up to R = 1000000).

The relationships between radius, m/z ratio and velocity or kinetic energy (E) can be then easily obtained: r mv zb r E2m zb For a given m/z ratio the radius of the cyclotron orbit dipends linearly on the ion velocity or on the square root of kinetic energy. If an ion in equilibrium with the surrounding environment at a temperature of T Kelvin is considered, kinetic energy E can be expressed as kt, where k is the Boltzmann constant. Then: 298 Kelvin

Trapping motion Trapping motion is triggered by the application of a small symmetrical positive (negative) voltage to the trapping plates (that are perpendicular to the magnetic field), leading to the storage of positive (negative) ions within the ICR cell: Potential well y z x B Ions undergo simple harmonic oscillation between the trapping plates along the magnetic field axis.

Magnetron motion The combination of the magnetic and electric fields creates a threedimensional ion trap, allowing ions to be stored in the ICR cell for seconds, minutes or even hours, i.e. times many orders of magnitude longer than typical residence times in most other mass spectrometers. Although it would seem that the magnetic and electric fields operate indipendently, their combination introduces a third fundamental ion motion in the ICR cell, the magnetron motion. In order to understand magnetron motion, the actual electric potential in the cell has to be considered. Indeed, while the trapping plates are subjected to the trapping potential, V t, the detection and excitation plates are grounded: The potential at the center of the cell is then given by the equation: y z x V t

If a section of the ICR cell, normal to the z axis, is considered, the plot of the electric potential in the corresponding x-y plane is: y z x B The potential surface is radially repulsive, thus the electric field drives ions away from the center of the analyzed cell, although it keeps them close to the central x-y section.

While being pushed outwards in a x-y plane, an ion is subject to the Lorentz force, due to the magnetic field. y z Indeed, any radial ion motion (continuous red vector) can be divided into two components, along x and y directions (dotted vectors), that are normal (not parallel) to the magnetic field. B x The resulting effect is the magnetron motion: a precession of the cyclotron motion of an ion around the center of the cell. The reported simulation refers to the following parameters: 4.4 cm cubic cell, m/z = 500, V t = 3 V, B = 1 Tesla

The magnetron radius (red) of an ion (in the figure it is purposely emphasized with respect to the cyclotronic motion radius, the blue one) depends on its initial displacement from the z axis when the ion itself is injected or created in the ICR cell. The magnetron motion frequency is a function of the trapping potential, V, the distance, a, between the trapping plates and the geometry of the ICR cell ( = 1.39 for a cubic cell): The magnetron frequency is usually in the order of 1-100 Hz, thus much lower than the cyclotron one. Moreover, it is independent on the m/z ratio.

Since ion oscillate along the z axis as a result of the trapping potential, three motions are present contemporarily in a ICR cell and can be schematically represented by the following picture: The combination of the three motions leads to a very complex trajectory for each ion population:

Effect of collisions on magnetron motion When ions are detected the pressure inside a ICR cell is about 10-9 Torr or lower, so that collisions do not occur frequently. However, during some FT-MS experiments the pressure needs to be raised, sometimes by several orders of magnitude. Ion-neutral collisions cause a decrease in ion kinetic energy/velocity. The cyclotron radius (r c = mv/zb) is then rapidly reduced; contemporarily, ions drift towards the cell edge and are finally neutralized by hitting the plates (collisionally mediated radial diffusion): P = 0.01 Torr

Events sequence in a FT-ICR-MS measurement Differently from most other mass spectrometers, in a FT-ICR-MS instrument mass analysis and ion detection (sometimes even ionization) occur in the same space (the ICR cell) but at different times. A typical experimental sequence consists in four main events: Quench: the cell is emptied of any ions deriving from previous experiments by applying antisymmetric voltages to the trapping plates. In a few ms the ions are ejected axially. Ionize: ionization may occur inside the ICR cell (i.e. by electron ionization). Alternatively, ions generated outside the cell can be guided into the cell through electrostatic or RF ion gates.

Ion excitation / detection Excitation and detection of ions in a ICR cell are strictly related, the former being mandatory for the latter to be performed. Ions in the trap are excited by applying a sinusoidal voltage to the excitation plates: when their cyclotron frequency c is in resonance with the exciting field frequency they absorb energy and spiral outwards into a larger cyclotron orbit: Ions having the same m/z ratio will be excited coherently, a fundamental step for their detection.

When a population of isobaric positive (negative) ions passes coherently near a detection plate of the ICR cell, due to cyclotronic motion, electrons are attracted (repelled) by the plate. An alternate current, known as image current, is generated into the external circuit connecting the detection plates and then amplified, digitized and stored for subsequent computer processing. Its frequency is given by c - m, thus it is nearly equal to the cyclotronic frequency (since the magnetronic frequency is much lower). The measurement of the image current frequency can be performed with extreme precision, thus giving FT-ICR-MS the highest accuracy currently achievable in m/z measurements. Moreover, ion detection is completely not destructive, an almost unique feature between mass analyzers (although some experiments show that image currents could be registered also in quadrupolar traps).

Broad-band excitation/detection Ions with different m/z ratios can be detected simultaneously by FT-ICR- MS if a broad-band excitation is performed. In this case a frequency synthesizer is programmed to sweep over frequencies from 10 khz to 1 MHz in a 1 ms period: each ionic population with a specific m/z ratio is subjected to resonance at a characteristic cyclotron frequency and the image current becomes a composite of sinusoids of different frequencies and amplitudes. The Fourier transform of the time transient provides frequency components and then the distribution of m/z ratios (by applying a calibration formula derived from the cyclotron frequency equation):

The image current transient and the multi-charge mass spectrum obtained by FT-ICR-MS for ubiquitin (8500 Da) are shown in the following picture:

Resolution in FT-ICR-MS The maximum resolving power (RP) achievable by FT-ICR-MS is expressed by the equation: where T is the duration of the time transient. R = 90,000 4 Note that the RP is proportional to the magnetic field B. R = 12,000 The length of T can be limited by collisions between ions and neutrals, with loss of coherence. At 10-10 Torr pressures transients of 60 s can be achieved and R > 10 6 can be reached.

An astonishing example of the extreme resolving power achievable by FT-ICR-MS is shown in the following spectrum: It is a detailed view of the m/z interval related to nominal mass 35 u, where the signals due to a positive and a negative 35 Cl ion were detected by alternatively acquiring, storing and transforming the corresponding image current transients. The m/z difference between the two peaks is related to the mass shift due to the two additional electrons in 35 Cl -, i.e. 0.00109 u.

MS/MS measurements with FT-ICR-MS A typical MS/MS experimental sequence with FT-ICR-MS can be described as follows: In this case, after ionization, a mass selection stage is required to isolate a specific precursor ion: a suitable excitation pulse with appropriate frequencies and amplitudes is applied to the cell to remove unwanted ions.

A very efficient approach to mass selection is the so called Stored Waveform Inverse Fourier Transform (SWIFT), developed by Marshall and his coworkers in the mid 1980s. The stages of SWIFT are: elaboration of the desired excitation spectrum calculation of the excitation waveform by Inverse Fourier Transform (IFT) application of the waveform to the ICR cell In the reported example, also the precursor ion is excited, but with half energy, so that its isolation and fragmentation occur contemporarily.

Quadrupolar excitation and axialization in FT-ICR-MS In the 1990s it was demonstrated that cyclotron (continuous line) and magnetron (dashed line) motions can be periodically interconverted if an ion is excited at its cyclotron frequency by a potential having quadrupolar simmetry: L. Schweikhard, A.G. Marshall, J. Am. Soc. Mass Spectr., 1993, 4, 433-452

As cyclotron motion is much faster than magnetron one, exposing a precursor ion to quadrupolar excitation in the presence of a relatively high gas pressure (up to 10-5 Torr) will result in a more significant dampening of the cyclotron motion. The final effect is ion relaxation to the center of its orbit, a process usually known as axialization.

When axialization is accomplished on a specific ion the other ones will be subject to typical radial diffusion and will be finally ejected. Precursor ions are then selected and several ions can be isolated in the same experiment if a composite or a SWIFT waveform is applied for the quadrupolar excitation. Further applications of axialization are: thermalization of excited state ions by quadrupolar excitation when they are placed near the cell center; signal-to-noise enhancing by repeated detection of the same set of ions: in this case quadrupolar excitation is used to return ions to the center after a dipolar excitation/detection stage. Repeating the procedure several times and averaging the image current transients thus obtained leads to a significant increase of sensitivity. Attomoles (10-18 moles) sensitivities have been reported for MALDI-FT-ICR-MS adopting this approach.

Translational excitation After selection, translational excitation of the precursor ion is accomplished by enlarging its cyclotron radius and thus increasing its kinetic energy E, since r = (E2m) 1/2 /zb. As an example, a mono-charged ion with m/z 1000, excited to a 2 cm radius orbit, at B = 7 Tesla, will acquire a kinetic energy of 950 ev. Collisional activated dissociation (CAD) After precursor ion selection and excitation an inert gas is admitted into the ICR cell through a pulsed valve. Ion-atoms (or molecules) collisions occur and product ions are generated by collisional activated dissociation (CAD). The main drawback of this procedure is that product ions are generated far from the center cell, which limits the efficiency and resolution for the MS/MS experiment.

Linear Ion Trap FT-ICR-MS hybrid system The MS/MS, MS n capabilities of linear ion trap have been coupled to the extreme mass resolution of a ICR cell to obtain a powerful mass spectrometer (LTQ-FT Ultra from Thermo Electron): HPLC ECD: Electron Capture Dissociation IRMPD: InfraRed Multi Photon Dissociation

The main figures of merit of this LIT-ICR instrument are: mass range: 50-4000 u resolution: 100000 at m/z 400 at 1 s/scan; > 750000 at m/z 400 at slower scan repetition rates (ICR operated in broadband mode) mass accuracy: < 1.2 ppm RMS error, with external calibration; < 1 ppm RMS error with internal calibration sensitivity: sub femtomoles (10-15 moles) attomoles (10-18 ) for peptides dynamic range: > 4000

Another very important feature is the possibility of double detection, that can be performed even in a parallel approach: In the first part of the experiment, a pre-scan is performed with the LIT, then ions are partly injected in the ICR trap for high accuracy/resolution MS scan. The remaining ions are subject to parallel MS/MS acquisitions in the LIT.

An example of LIT-ICR power: distinction between almost isobaric compounds (two mutant peptides).