Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment

Similar documents
Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

OES - Optical Emission Spectrometer 2000

Trace Analyses in Metal Matrices Using the ELAN DRC II

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Samples compliant with the WATER

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Sample Analysis Design PART II

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Debjani Banerjee Department of Chemical Engineering IIT Kanpur

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Sample Analysis Design PART III

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

Following documents shall be used for reference on quantities, units, prefixes and other technical vocabulary in this document:

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

ENVG FALL ICP-MS (Inductively Coupled Plasma Mass Spectrometry) Analytical Techniques

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

PRINCIPLE OF ICP- AES

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Defining quality standards for the analysis of solid samples

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

Distillation purification and radon assay of liquid xenon

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

Partial Energy Level Diagrams

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

7) Applications of Nuclear Radiation in Science and Technique (1) Analytical applications (Radiometric titration)

Analysis Repeatability of Trace and Major Elements in a Water Sample

Select Assay Capabilities at PNNL

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Ar Ar + e - INDUCTIVELY+COUPLED+ PLASMA+SPECTROMETRY+ What+is+Plasma?+ FuncDon+of+Plasma+

ANALYSIS CERTIFICATE OF

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

The 30-Minute Guide to ICP-MS

Acronyms, Abbreviations, and Symbols Foreword to the First Edition Foreword to the Second Edition Preface to the First Edition Preface to the Second

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution

Fergus Keenan Shona McSheehy Julian Wills

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry: acquiring basic skills and solid sample meausurements

Low level Os isotopic measurements using multiple ion counting

Analysis of domestic sludge using the Agilent 4200 MP-AES

Nuclear Magnetic Resonance (NMR)

Atomic Spectroscopy AA/ICP/ICPMS:

Florida State University Libraries

RADIOLOGICAL CHARACTERIZATION Laboratory Procedures

The LUCIFER project current status and perspective!!!

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry

Sample Analysis Design Polyatomic Interferences

GERDA: The GERmanium Detector Array for the search for neutrinoless decays of 76 Ge. Allen Caldwell Max-Planck-Institut für Physik

NATURE AN POLUUTION DEGREE OF WATER ASSETS STUDIED BY INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROSCOPY

Rapid, simple, interference-free analysis of environmental samples using the XSERIES 2 ICP-MS with 3 rd generation CCT ED

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT#

Implementing EPA Method 6020 with the Agilent ICP-MS Portfolio

Determination of Elements at Sub-ppb Concentrations in Naphtha Mixtures Using the NexION 300 ICP-MS

Status of the AMoRE experiment searching for neutrinoless double beta decay of 100 Mo

ICP-OES Application Note Number 35

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Agilent Technologies at TIAFT 2013

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

CHAPTER 4: ANALYTICAL INSTRUMENTATION

Hands on LUNA: Detector Simulations with Geant4

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

Performance of the Agilent 7900 ICP-MS with UHMI for high salt matrix analysis

Transcription:

: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment Max Planck Institute for Nuclear Physics, Heidelberg, Germany E-mail: mykola.stepaniuk@mpi-hd.mpg.de Stefano Nisi E-mail: stefano.nisi@lngs.infn.it Marco Balata E-mail: marco.balata@lngs.infn.it In the Gran Sasso Summer Institute 2014 Hands-On Experimental Underground Physics at LNGS I tried myself as an operator of an ICP-MS instrument. Two spectrometers were calibrated and used for an assay of contamination (by the elements which are important for the crystal growth and scintillation properties of the detectors) and isotopic composition of the LUCIFER 82 Se samples. Obtained results are consistent with expectations based on previous studies. Gran Sasso Summer Institute 2014 Hands-On Experimental Underground Physics at LNGS - GSSI14, 22 September - 03 October 2014 Speaker. The author thanks the LNGS Chemistry Service and Chemical Plant personnel c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence. http://pos.sissa.it/

1. Introduction LUCIFER is an upcoming experiment for the search of neutrinoless double beta decay (0νβ β) of 82 Se with the help of ZnSe scintillating bolometers [1]. Operated at extremely low temperatures ( 10 mk) such devices need high purity crystals with a very good crystal perfection and a low level of intrinsic radioactivity. Moreover, in the case of 0νββ application the nuclide of interest is required in sufficient amount, i.e. isotope enriched materials should be employed. The simplified production scheme of crystals for the LUCIFER experiment is as follows: 1) raw Se refinement 2) SeF 6 synthesis 3) SeF 6 enrichment 4) Se conversion 5) Se beads production 6) 82 Se enrichment 7) purification 8) ZnSe synthesis 9) ZnSe crystal growth 10) mechanical processing 11) recovery and recycling 12) package and shipment. The purity of Zn and Se used for the synthesis of ZnSe and crystal growth is particularly important. Point defects due to impurities may act as traps both for the phonons involved in the development and propagation of bolometric signal and for the free carriers involved in the scintillation process. The purity issue is more difficult in the case of the enriched selenium given the complexity of its production process. Special care is taken in order to reduce the contamination with impurities defined as critical for the scintillation performance of ZnSe crystals (Fe, Cr, V, Ni, As, Cu, Mo, Si, and S). Two samples of the enriched 82 Se material (after step 7 in the production chain) were sent to the LNGS Chemistry Service and Chemical Plant for the ICP-MS analysis of the contamination by the elements which are important for the crystal growth and scintillation properties of the detectors. Besides that the isotopic composition of the enriched samples is to be compared with the natural selenium. 2. Instrumentation Inductively coupled plasma mass spectrometry (ICP-MS) has a leading place among all the inorganic mass spectrometric techniques [2]. An inductively coupled plasma is a plasma that is ionized by inductively heating the gas with an electromagnetic coil, and contains a sufficient concentration of ions and electrons to make the gas electrically conductive. It has a wide range of application: medical, forensic, environmental research, industrial and biological monitoring, geochemistry etc. For our purposes we used THERMO ELEMENT2 and Agilent 7500a ICP-MS devices located in a cleanroom (ISO6, class 1000). Sample introduction was done with CETAC ASX-520 AutoSampler. Both instruments used liquid samples, which were prepared in advance by dissolving received solid material (balls 2 mm in diameter) in 1 ml of 70% HNO 3 in ultrasonic bath at 70 C for an hour and then diluting them with ultrapure water up to the values given in Table 1. The operator prepares the solutions, sets up the necessary sequence in the computer software, starts the program and within several (tens of) minutes the following stages should be automatically passed to get a spectrum: sample introduction (liquid solution uptake with a help of peristaltic pump); vaporization in nebulizer of the sample mixed with argon gas; spray chamber selects droplets of size less than 10 microns; atomization and ionization in the plasma torch; ion acceleration and focusing; mass separation in a double focusing alalyzer (combination of magnetic 2

Sample Label Mass, mg Total dilution 1 Selenium82 Conv. 31 65 1846 2 Selenium82 Conv. 36 99 1818 Table 1: Labels, masses and total dilution of the two studied samples. Both samples were dissolved in 1 ml of 70% HNO 3 and diluted with ultrapure water. and electric sector fields) for THERMO ELEMENT2 or quadrupole for Agilent 7500a; energy focusing; ion detection with a secondary electron multiplier. The plasma is generated in a quartz glass torch by inductive coupling to a radiofrequency (RF 27 MHz) power source. The load coil, located at one end of the torch, is hollow and internally cooled by water. The RF magnetic field causes motion of free electrons within the Ar gas, causing intense heating (up to 10000 K). The plasma temperature is selected to maximise ionisation efficiency for the elements with a high first ionisation energy, while minimising second ionisation (double charging) for elements that have a low second ionisation energy. Ionisation is caused by collisions between free electrons and Ar gas atoms. Making the plasma from argon, instead of other gases, has several advantages. First, argon is abundant (in the atmosphere, as a result of the radioactive decay of potassium) and therefore cheaper than other noble gases. Argon also has a higher first ionization potential than all other elements except He, F, and Ne. Because of this high ionization energy, the recombination of argon is energetically more favorable than the recombination of the sample atom. This ensures that the sample remains ionized so that the mass spectrometer can detect it. A fraction of the formed ions passes through a 1 mm hole (sampler cone) and then a 0.4 mm hole (skimmer cone). Their purpose is to allow a vacuum that is required by the mass spectrometer. The pressure in the torch is 1 bar, between the cones 10 3 bar and behind the cones 10 7 bar. Argon acts here as a carrier a cooling gas. The mass range of ELEMENT2 is 2 260 a.m.u. and dynamic range is >10 9. It has high ionization yields (>90%) for almost all elements. For ELEMENT2 the resolution R = m/ m, where m = FW(5%)M, is constant in the whole mass range, while for quadrupole machine it is a function of mass. ICP-MS has great speed, precision, and sensitivity. However, compared with other types of mass spectrometry, such as TIMS and Glow Discharge, ICP-MS introduces a lot of interfering species: argon from the plasma, component gasses of air that leak through the cone orifices, and contamination from glassware and the cones. THERMO ELEMENT2 has three resolutions to choose from. Low resolution (R = 300) is used for the analysis of non-interfered isotopes. In this mode the ELEMENT2 sensitivity is the highest of all commercially available ICP-MS instruments. Additionally, the flat top peak shape is an advantage for high precision isotope ratio measurements. Medium resolution (R = 4000) guarantees interference-free analysis for most elements in the majority of sample matrices. For example, transition elements are routinely measured in medium resolution due to the formation of many interfering polyatomic species in the mass range 24 70 a.m.u. High resolution (R = 10000) is used for the analysis of elements in the most challenging sample matrices. The main advantage of high mass resolution as a technique to remove spectral interferences is that it is not just limited to a particular type of interference. For example with high resolution of ELEMENT2 iron at m/z = 56 3

Figure 1: Calibration curve for 39 K obtained on THERMO ELEMENT2 at high resolution (R=10000). is easily separated in a simple matrix from 40 Ar 16 O as well as in more complex matrices from, for example, 40 Ca 16 O. 3. Calibration We used tune-up solution containing 1 µg/l of B, Ba, Co, Fe, Ga, In, K, Li, Lu, Na, Rh, Sc, Tl, U and Y dissolved in a 5% HNO 3 to make a calibration of ELEMENT2. For the Agilent 7500a we used tune-up agilent containing 1 ppb of natural Li, Y, Ce, Tl. The calibration curve, linking counting rate (cps) with concentration (ppb), for 39 K at high resolution (R = 10000) obtained on ELEMENT2 is shown in Figure 1. 4. Measured contamination and enrichment of the samples The measured contamination and enrichment of the samples is given in Table 2 and Table 3, respectively. Numbers in the Table 2 were obtained on THERMO ELEMENT2, while the ones in Table 3 on Agilent 7500a. Uncertainties of the contamination values are 30% due to a high purity of material and the presence of background (measured with a blank solution). 5. Summary In the Gran Sasso Summer Institute 2014 Hands-On Experimental Underground Physics at LNGS I tried myself as an operator of an ICP-MS instrument. The spectrometers were calibrated and used for the measurement of contamination by certain elements and isotopic composition of the LUCIFER 82 Se samples. Obtained results are consistent with expectations based on previous studies. This technique (together with HPGe measurements) is an integral part of any low-background experiment. I believe I will definitely find an application to acquired knowledge in my future work. 4

Isotope n 1, ppb n 2, ppb 24 Mg (LR) < 90 < 90 55 Mn (LR) < 20 < 20 59 Co (LR) < 20 < 20 63 Cu (LR) < 27 18 110 Cd (LR) < 20 < 20 182 W (LR) 33 18 206 Pb (LR) < 40 < 40 209 Bi (LR) < 1 < 1 232 Th (LR) < 1 < 1 238 U (LR) < 2 < 2 23 Na (LR) < 1000 3300 121 Sb (LR) < 2 < 2 202 Hg (LR) < 2 < 3 125 Te (LR) 3300 5400 Isotope n 1, ppb n 2, ppb 95 Mo (LR) 24 14 152 Sm (LR) < 2 < 2 27 Al (MR) < 1800 < 1800 44 Ca (MR) < 7000 < 7000 52 Cr (MR) < 20 < 20 56 Fe (MR) < 500 < 500 28 Si (MR) 14000 < 10000 51 V (MR) < 90 < 90 32 S (MR) 185000 180000 58 Ni (MR) < 100 < 100 75 As (MR) < 90 < 50 59 Co (MR) < 10 < 10 39 K (HR) < 1800 < 1800 Table 2: Contamination of the samples measured with THERMO ELEMENT2. The concentrations of the isotopes of interest in ppb (10 9 g/g) are refered to solid samples. n 1 for sample 1; n 2 for sample 2. LR low resolution (R=300), MR medium resolution (R=4000), HR high resolution (R=10000). Uncertainties are about 30%. Se isotope Ref. Nat., % Exp. Nat., % Exp. Enr., % 74 0.89 0.72 ± 0.02 < 0.001 76 9.37 8.66 ± 0.26 < 0.08 77 7.63 6.74 ± 0.20 < 0.004 78 23.77 23.31 ± 0.70 < 0.02 80 49.61 50.94 ± 1.53 4.8 ± 1.4 82 8.72 9.63 ± 0.29 95.1 ± 2.9 Table 3: Experimental and reference values of the isotopic composition of enriched and natural selenium samples. Results were obtained on Agilent 7500a. References [1] I. Dafinei, The LUCIFER project and production issues for crystals needed in rare events physics experiments, Journal of Crystal Growth 393 (2014) 13 17 [2] J. S. Becker, Inorganic mass spectrometry: principles and applications, John Wiley & Sons, Chichester 2007 [3] S. Nisi et al., Comparison of inductively coupled mass spectrometry and ultra low-level gamma-ray spectroscopy for ultra low background material selection, Applied Radiation and Isotopes 67 (2009) 828 832 5