Deuterium Gas Analysis by Residual Gas Analyzer

Similar documents
ION Pumps for UHV Systems, Synchrotrons & Particle Accelerators. Mauro Audi, Academic, Government & Research Marketing Manager

Critical Current Properties of HTS Twisted Stacked-Tape Cable in Subcooled- and Pressurized-Liquid Nitrogen

Extrel Application Note

A Report On DESIGN OF NEUTRON SOURCES AND INVESTIGATION OF NEUTRON BASED TECHNIQUES FOR THE DETECTION OF EXPLOSIVE MATERIALS

Anomalous production of gaseous 4 He at the inside of DScathode during D 2 O-electrolysis

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

Chapter 13: Partial Pressure Analysis

Sputter Ion Pump (Ion Pump) By Biswajit

~1 V ~20-40 V. Electron collector PLASMA. Ion extraction optics. Ionization zone. Mass Resolving section Ion detector. e - ~20 V Filament Heater

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

TRITIUM PRODUCTION IN PALLADIUM DEUTERIDE/HYDRIDE IN EVACUATED CHAMBER

Quadrupole Mass Spectrometry Concepts. Mass spectrometers for residual gas analysis: Intermediate Level Users Guide

Influence of gas conditions on electron temperature inside a pinch column of plasma-focus discharge

Lecture 3 Vacuum Science and Technology

POLARIZED DEUTERONS AT THE NUCLOTRON 1

k T m 8 B P m k T M T

Continued Work toward XHV for the Jefferson Lab Polarized Electron Source

Reproduction of Fleischmann and Pons experiments

Jumbo Cross Beam Ionizer

Study of Distributed Ion-Pumps in CESR 1

Plasma Chamber. Fortgeschrittenes Praktikum I. Supervisors: Baran Eren, Dr. Marco Wisse, Dr. Laurent Marot. Abstract

Nuclear reactions produced in an operating electrolysis cell. Abstract

High-Pressure Volumetric Analyzer

D- Charge Exchange Ionizer for the JINR Polarized Ion Source POLARIS

AQA Chemistry (Combined Science) Specification Checklists. Name: Teacher:

Effect of Electrolyte Concentration during Solution Plasma on Copper Nanoparticle Size

Relative Sensitivity RS Measurements of Gases

A novel sputtering technique: Inductively Coupled Impulse Sputtering (ICIS)

NUCLEAR TRANSMUTATION IN DEUTERED PD FILMS IRRADIATED BY AN UV LASER

MS Goals and Applications. MS Goals and Applications

STRONG DOUBLE LAYER STRUCTURE IN THERMIONIC VACUUM ARC PLASMA *

Generation of vacuum (pumps) and measurements

Replication Of MHI Transmutation Experiment By D 2 Gas Permeation Through Pd Complex

Partial Energy Level Diagrams

Autoresonant Ion Trap Mass Spectrometer The RGA Alternative

Partial pressure gauges

1 AT/P5-05. Institute of Applied Physics, National Academy of Sciences of Ukraine, Sumy, Ukraine

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Electrical Discharges Characterization of Planar Sputtering System

Glossary of Common Laboratory Terms

Performance of Palladium Diffusers for Reliable Purification of Hydrogen

Iron is extracted in a blast furnace. Figure 1 is a diagram of a blast furnace. Calcium carbonate decomposes at high temperatures.

Vacuum II. G. Franchetti CAS - Bilbao. 30/5/2011 G. Franchetti 1

vacuum analysis plasma diagnostics surface science gas analysis

ENVG FALL ICP-MS (Inductively Coupled Plasma Mass Spectrometry) Analytical Techniques

Lecture 10. Vacuum Technology and Plasmas Reading: Chapter 10. ECE Dr. Alan Doolittle

The Claviature of Gas Analysis

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

Vacuum measurement on vacuum packaged MEMS devices

Angular Correlation Experiments

BALKAN PHYSICS LETTERS Bogazici University Press 15 November 2016 BPL, 24, , pp , (2016)

EVIDENCE FOR PRODUCTION OF TRITIUM VIA COLD FUSION REACTIONS IN DEUTERIUM GAS LOADED PALLADIUM

Yasuhiro Iwamura, Takehiko Itoh, Nobuaki Gotoh and Ichiro Toyoda

Section 5: Thin Film Deposition part 1 : sputtering and evaporation. Jaeger Chapter 6. EE143 Ali Javey

MS Goals and Applications. MS Goals and Applications

Anomalous Heat Generation in Charging of Pd Powders with High Density Hydrogen Isotopes (I) Results of absorption experiments using Pd powders

Experimental Study of Plasma Under-liquid Electrolysis in Hydrogen Generation

nm

TPRS with MATLAB and quantitative mass spec review. Cassandra Siler

a. An emission line as close as possible to the analyte resonance line


MICROCHIP MANUFACTURING by S. Wolf

Design considerations for linear Paul trap mass spectrometer under development

A simple calorimetric method to avoid artifacts in a controversial field: the ice calorimeter

Unit 12 Conduction in Liquids and Gases

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Successful Development of a New Catalyst for Efficiently Collecting Tritium in Nuclear Fusion Reactors

First Experiments in SST-1

Huashun Zhang. Ion Sources. With 187 Figures and 26 Tables Э SCIENCE PRESS. Springer

National 5 Chemistry

FINE PATTERN ETCHING OF SILICON USING SR-ASSISTED IONIZATION OF CF4 GAS

SORB-AC Getter Wafer Modules and Panels. We support your innovation

Quadrupole Miniaturization: Revisited

Fig.1 Pyrex glass cell

Relationship between production and extraction of D - /H - negative ions in a volume negative ion source

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

GCE AS and A Level. Physics A. AS exams 2009 onwards A2 exams 2010 onwards. Unit 5: Approved specimen question paper. Version 1.3

Edexcel Chemistry Checklist

CH0302 Process Instrumentation. Lecture 9 Composition Analysis

RGA modelling and simulation to include pressure dependence in the ion source

Mole Concept 5.319% = = g sample =

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

FAIMS Technology at a Glance

Lecture 4. Ultrahigh Vacuum Science and Technology

Power generation properties of Direct Flame Fuel Cell (DFFC)

Teflon lid. O ring. Catalyst. Catalyst Chamber. Electrolyte (H 2 SO 4 + de-ionized H 2 0)

AUTORADIOGRAPHY OF DEUTERATED Ti AND Pd TARGETS FOR SPATIALLY RESOLVED DETECTION OF TRITIUM PRODUCED BY COLD FUSION

laser with Q-switching for generation of terahertz radiation Multiline CO 2 Journal of Physics: Conference Series PAPER OPEN ACCESS

AND LIMITATIONS K. BALOGH

Multiscale integral analysis of a HT leakage in a fusion nuclear power plant

12 Moderator And Moderator System

An important fuel is methane, natural gas. The equation for its combustion is as follows. CO 2 + 2H 2 O

DEVELOPMENT OF A COMBUSTION SYSTEM FOR LIQUID OR GAS SAMPLES

Cleaning Electronegative Contamination from Gaseous Xenon Through Cryogenic Pumping

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

Experimental study on heat losses from external type receiver of a solar parabolic dish collector

Electrolysis SCIENCE TOPICS PROCESS SKILLS VOCABULARY

PIC Algorithm with Multiple Poisson Equation Solves During One Time Step

Sub-category: Physics and Principles of Measurement Topic: Monitoring anesthetic gases and vapours Date: January 15-17, 2016 Language: English

Transcription:

Journal of Physics: Conference Series Deuterium Gas Analysis by Residual Gas Analyzer To cite this article: B K Das et al 2012 J. Phys.: Conf. Ser. 390 012009 View the article online for updates and enhancements. Related content - Study of Residual Gas Analyser (RGA) Response towards Known Leaks Firozkhan S Pathan, Ziauddin Khan, Pratibha Semwal et al. - Spinning rotor gauge based vacuum gauge calibration system at the Institute for Plasma Research (IPR) Pratibha Semwal, Ziauddin Khan, Kalpesh R Dhanani et al. - Evaluation of Ti-Zr-V (NEG) Thin Films for their pumping speed and pumping Capacity Tripti Bansod, B K Sindal, K V A N P S Kumar et al. This content was downloaded from IP address 148.251.232.83 on 02/10/2018 at 18:46

Deuterium Gas Analysis by Residual Gas Analyzer B K Das *,1, R Shukla 1, R Das 1, A Shyam 1 and A D P Rao 2 1 Energetics & Electromagnetics Division, Bhabha Atomic Research Centre, Autonagar, Visakhapatnam, India 2 Nuclear Physics Deaprtment, Andhra University, Visakhapatnam, India Corresponding author s e-mail: dasbabu31@gmail.com Abstract. Hydrogen gas is generated by electrolysis method in a compact hydrogen generator. A simple procedure reduces handling and storage of hydrogen cylinders for laboratory applications. In such a system, we are producing deuterium gas from heavy water by electrolysis method. After production of the deuterium gas, we have checked the purity level of the outgoing deuterium from the electrolyser. The test was carried out in a high vacuum system in which one residual gas analyser (RGA) was mounted. The deuterium gas was inserted by one manual gas leak valve in to the vacuum system. In this study, the effect of the emission current of the RGA on the detection of the deuterium was performed. In this paper, we will discuss the detail analysis of the deuterium gas and the effect of the emission current on the partial pressure measurement. 1. Introduction Use of modern available technology for the basic requirements in research and development laboratories becomes important due to various safety reasons. One of the most important safety issues is handling of pressurized gas cylinders specifically for the flammable gases. Handling and use of hydrogen cylinders in laboratories requires lot of precautions. To avoid such safety issues related to handling, storage and use of hydrogen cylinders, we are working on one electrolysis system [1] for generation of hydrogen isotopes. Deuterium gas is generated by this electrolysis system from heavy water. The purity of the gases produced by this system is important for our application. The purity of the deuterium gas produced by an electrolysis system in our laboratory was checked in a high vacuum system by residual gas analyzer. In the next sections we will discuss about the detail experimental set up and the results. 2. Experimental set up We are using one compact electrolysis system purchased from M/s. PCI Analytical Pvt. Ltd [2]. The photograph of the system is shown in figure 1. The electrolysis flow diagram is shown in figure 2. Potassium Deuteroxide ( KOD) is used as electrolyte and heavy water. The usage of voltage across the electrolyte results in hydrolysis, breaking down the heavy water molecule into deuterium and oxygen gas, which are separated by the gas permeable membrane. To achieve the desired level of purity, the deuterium gas goes through series of purification and moisture removal systems while the oxygen gas is being discharged into the atmosphere. The electrolytic membrane technology has its own benefits over alternative hydrogen gas generator techniques as it is clean and requires minimum maintenance. Published under licence by IOP Publishing Ltd 1

The deuterium gas thus produced by the electrolysis system is tested by one residual gas analyzer (RGA), Hiden Analytical Ltd., UK [3] make, mounted on a high vacuum system pumped by turbo molecular pump as per the figure 3. A vacuum in the order of 3.5E-7 Torr was achieved without baking. The deuterium gas was inserted into the chamber by one manual gas leak valve. The basic principle of the RGA is based on ionize and measurement [4]. RGA ionizes the neutral gases and then measure the ion current. The ion current directly corresponds to the number of neutral molecules of that particular ion. Neutral molecules present inside the vacuum chamber are ionized by one electron impact ion source present inside the RGA assembly. Once the gas is ionized they are focused to one filter system made of four electrodes know as quadruple. The quadruple filters the ions on the basis of their mass to charge ratio. The quadruple is powered by RF and DC voltages. The RF power makes the ions to oscillate inside the quadruple where as the DC voltage absorbs the unwanted ions when they strike any of the electrode surfaces. The ions those are passed through the quadruple are detected at the end either by one faraday cup or by channel electron multiplier. The RGA was operated in profile mode and MID mode. In profile mode, RGA does series of scans for each mass number. The scans were performed for different emission current of the filament. The emission current decides the ionization probability of the neutral gas molecules in the vicinity of the ion source. Fig. 1. Photograph of Hydrogen Generator Fig. 2. Flow Diagram of Hydrogen Generator 2

Fig. 3. Photograph of Experimental Set Up 3. Results With the above experimental set up different spectrum were obtained from RGA for deuterium concentration, it s stability and the effect of emission current on the deuterium measurement. The spectrum obtained with the background i. e. without the filling of deuterium is shown in figure 4. From this figure, it could be observed that the vacuum system is free from leaks. The Oxygen signal at mass number 32 is absent, the nitrogen signal at mass number 28 is very less and there is no peak at mass number 14. The peak at mass number 28 is a contribution from carbon monoxide, carbon dioxide and nitrogen. As the vacuum system is not exposed to any heat, presence of water vapor in the system is unavoidable. The peak at masss number 18, 17, 2 and 1 are due to the presence of water vapor in the system. Fig. 4. Spectrum of profile scan of RGA for background 3

The spectrum shown in figure 5 is obtained with the deuterium filled pressure at 2.5E-5 Torr. The peak at mass number 4 is due to deuterium. In the spectrum there is no other significant peak is shown. There is a very little peak at mass number 3, which is due to formation of DH (Deuterium Hydride). This may be due to the presence of residual hydrogen left behind while the system was tested for hydrogen production. The formation of DH molecule may disappear after long use of the system for the production of deuterium. Another very little peak at mass number 18 is due to the presence of water vapor in the vacuum chamber even before filling of the deuterium gas. The spectrum shows free from any shorts of impurities. Fig. 5. Spectrum of profile scan of RGA with deuterium filled pressure The electrolysis system continuously generates deuterium. To check the stability of the production of the deuterium, one MID scan was performed with the RGA. In MID scan, RGA continuously scans the particular mass number for given period of time. Such a scan is performed simultaneously for deuterium, oxygen, nitrogen and water vapor. Deuterium is for it s stability check and other molecules for their appearance during deuterium production either from electrolysis or from any other sources. Such a spectrum is shown in figure 6. The red line corresponds to deuterium where as the other colored lines for rest of the molecules. The red line once it is stable after production is steady throughout the measurement period for duration of ten minutes. In an effort to check the effect of electron emission current on the partial pressure measurement, one measurement was done for different emission current. The electron emission current helps for the efficient ionization of the neutral gases in RGA. The spectrum shown in figure 7 represents the effect of emission current on the partial pressure measurement of deuterium. Though here, deuterium gas was taken as the test gas, the result may be applicable to any other gases. There is an exponential growth of the partial pressure with the emission current. The measurement was done at filled pressure of 4.5E-5 Torr. It is observed that the more emission current, i. e. higher side of the instrument specification is giving correct measurement, where as the lower side of the emission current is giving more incorrect value. The idea of using the instrument with lower emission current may be helpful for suppression of background. 4

Fig. 6. MID scan of RGA for stability test of the deuterium production Fig. 7. Deuterium partial pressure Vs electron emission current 5

Conclusion In this work, the production of deuterium gas by compact electrolysis system was carried out. The purity of deuterium is checked by residual gas analyzer. The output deuterium from the electrolysis system was found to be ultra pure and stable. Residual impurities are absent. This type of system for deuterium/hydrogen production in laboratories is useful from safety and logistic point of view. The emission current of RGA should be at the specified value according to the supplier s specification. Any lower value may give incorrect measurement. References [1] http://en.wikipadia.org [2] http://www.pcianalytics.in [3] http://www. hidenanalytical.com [4] P. A. Redhead et al, The physical basis of ultrahigh vacuum,1993, NewYork 6