Available online at ScienceDirect. Procedia Engineering 150 (2016 )

Similar documents
ScienceDirect. Response Spectrum Analysis of Printed Circuit Boards subjected to Shock Loads

Nonlinear damping in vibration of CFRP plates

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Available online at ScienceDirect. Physics Procedia 70 (2015 )

Available online at ScienceDirect. Procedia Engineering 150 (2016 )

93. Study on the vibration characteristics of structural of hydrocyclone based on fluid structure interaction

ScienceDirect. Experimental Validation on Lift Increment of a Flapping Rotary Wing with Boring-hole Design

Available online at ScienceDirect. Procedia Engineering 157 (2016 )

Analysis of the Temperature Influence on a Shift of Natural Frequencies of Washing Machine Pulley

Available online at ScienceDirect. Physics Procedia 67 (2015 ) Performance test of a G-M cooler in magnetic field

643. Rod-shaped piezoelectric actuator with radial polarization

University of Bristol - Explore Bristol Research

Experimental and Numerical Modal Analysis of a Compressor Mounting Bracket

Available online at ScienceDirect. Physics Procedia 67 (2015 )

EXPERIMENTAL EVALUATION OF THE MODAL DAMPING OF AUTOMOTIVE COMPONENTS WITH DIFFERENT BOUNDARY CONDITIONS

Available online at ScienceDirect. XVII International Colloquium on Mechanical Fatigue of Metals (ICMFM17)

Available online at ScienceDirect. Procedia Engineering 113 (2015 )

EXPERIMENTAL DETERMINATION OF DYNAMIC CHARACTERISTICS OF STRUCTURES

ScienceDirect. Fatigue life from sine-on-random excitations

A STUDY OF THE ACCURACY OF GROUND VIBRATION TEST DATA USING A REPLICA OF THE GARTEUR SM-AG19 TESTBED STRUCTURE

ScienceDirect. Effect of Heat on the Performance of Novel Energy Harvester by using PZT-5H Transducers

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

EXPERIMENTAL MODAL ANALYSIS OF A SCALED CAR BODY FOR METRO VEHICLES

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class #

Vibration Measurements Vibration Instrumentation. MCE371: Vibrations. Prof. Richter. Department of Mechanical Engineering. Handout 11 Fall 2011

Available online at ScienceDirect. Procedia Engineering 150 (2016 )

10 Measurement of Acceleration, Vibration and Shock Transducers

Available online at ScienceDirect. Procedia Engineering 136 (2016 )

Modal Analysis Technique for Anisotropic Composite Laminates

Available online at ScienceDirect. Procedia Engineering 106 (2015 ) Dynamics and Vibroacoustics of Machines (DVM2014)

Flow-Induced Vibration of Pipeline on Elastic Support

Estimation of Unsteady Loading for Sting Mounted Wind Tunnel Models

Simple Harmonic Motion Investigating a Mass Oscillating on a Spring

Design and FEA Simulation of Omega Type Coriolis Mass Flow Sensor

433. New linear piezoelectric actuator based on traveling wave

Available online at ScienceDirect. Procedia Engineering 105 (2015 )

Available online at ScienceDirect. Procedia Engineering 113 (2015 )

Experiments in active control of panel vibrations with spatially weighted objectives using multiple accelerometers

Fine Tuning Coriolis Flow Meter Calibrations Utilizing Piece- Wise Linearization

Available online at ScienceDirect. Procedia Engineering 129 (2015 ) International Conference on Industrial Engineering

Available online at ScienceDirect. Procedia Engineering 90 (2014 )

Measurement Techniques for Engineers. Motion and Vibration Measurement

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

ACTIVE VIBRATION CONTROL PROTOTYPING IN ANSYS: A VERIFICATION EXPERIMENT

ScienceDirect. The Stability of a Precessing and Nutating Viscoelastic Beam with a Tip Mass

Dynamic Characteristics for Traditional Wooden Structure in Korea by Using Impact Hammer Test

EVALUATING DYNAMIC STRESSES OF A PIPELINE

MASS LOADING EFFECTS FOR HEAVY EQUIPMENT AND PAYLOADS Revision F

COMBUSTION DYNAMICS IN A RIJKE TUBE (PULSED COMBUSTOR) Learning Objectives

Identification of Lateral/Directional Model for a UAV Helicopter in Forward Flight

Committee Draft No. 99 To be combined with T-150 as a method B. Determination of Natural Frequency and Flexural Modulus by Experimental Modal Analysis

ScienceDirect. Contact Deformations under the Influence of Measurement Force

ScienceDirect. Centre of pressure detection and analysis with a high-resolution and low-cost smart insole

COUPLED USE OF FEA AND EMA FOR THE INVESTIGATION OF DYNAMIC BEHAVIOUR OF AN INJECTION PUMP

Available online at ScienceDirect. Procedia Engineering 91 (2014 ) 63 68

Available online at ScienceDirect. Procedia Engineering 185 (2017 ) Andreas Neumann a,*

ABSTRACT Modal parameters obtained from modal testing (such as modal vectors, natural frequencies, and damping ratios) have been used extensively in s

Power requirements for yield stress fluids in a vessel with forward-reverse rotating impeller

Finite Element Analysis of Piezoelectric Cantilever

Active elastomer components based on dielectric elastomers

Optimization and Numerical Simulation of Multi-layer Microchannel Heat Sink

Development of axial flux HTS induction motors

Study on the influence of design parameter variation on the dynamic behaviour of honeycomb sandwich panels

Using Operating Deflection Shapes to Detect Misalignment in Rotating Equipment

Damage detection in a reinforced concrete slab using outlier analysis

Available online at ScienceDirect. Procedia Engineering 152 (2016 )

Available online at ScienceDirect. Physics Procedia 67 (2015 ) Superfluid helium heat pipe. P.

Available online at ScienceDirect. Procedia Engineering 176 (2017 ) Dynamics and Vibroacoustics of Machines (DVM2016)

Evaluating New Generation Vibrating Tube Sensor for Density Measurement under Process Conditions

Application of laser vibrometer for the study of loudspeaker dynamics

Available online at ScienceDirect. Physics Procedia 63 (2015 )

Estimation of Rotational Degrees of Freedom by EMA and FEM Mode Shapes

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

INVESTIGATION OF IMPACT HAMMER CALIBRATIONS

Linearity of Coriolis Flowmeters at Full Scale Value. Dr. Jesús Aguilera - Endress + Hauser Paul Ceglia - Endress + Hauser

1. a) A flag waving in the breeze flaps once each s. What is the period and frequency of the flapping flag?

IDENTIFICATION OF VIBRATION PATH IN A GASOLINE DIRECT- INJECTION ENGINE USING TWO INPUT-ONE OUTPUT MODEL

MODELING OF PIPELINE VIBRATION UNDER THE PRESSURE RIPPLES IN THE WORKING FLUID

64. Measurement of vibrations of rotating elements in a folding machine

Available online at ScienceDirect. Procedia Engineering 191 (2017 )

Eliminating the Influence of Harmonic Components in Operational Modal Analysis

CONTRIBUTION TO THE IDENTIFICATION OF THE DYNAMIC BEHAVIOUR OF FLOATING HARBOUR SYSTEMS USING FREQUENCY DOMAIN DECOMPOSITION

Numerical simulation of the coil spring and investigation the impact of tension and compression to the spring natural frequencies

1405. Diagnostics of buggy vehicle transmission gearbox technical state based on modal vibrations

Available online at ScienceDirect. Procedia Engineering 150 (2016 )

Lectures Chapter 10 (Cutnell & Johnson, Physics 7 th edition)

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

1330. Comparative study of model updating methods using frequency response function data

Natural vibration frequency of classic MEMS structures

Available online at ScienceDirect. Procedia Engineering 147 (2016 )

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

Flow Structure Investigation in the Lateral Inlet Branches of Hydraulic Machines and Some Recommendations on Their Designing

Effective Modes of Axial Balancing of Centrifugal Pump Rotor

Experimental Study and Analysis of Flow Induced Vibration in a pipeline

Nonlinear Normal Modes: Theoretical Curiosity or Practical Concept?

EXPERIMENTAL MODAL ANALYSIS OF AN ACTIVELY CONTROLLED SCALED METRO VEHICLE CAR BODY

Using the Coriolis Acceleration to Design a Digital Mass Flow Meter

Transactions on Modelling and Simulation vol 16, 1997 WIT Press, ISSN X

Diagnostic testing of the comparator carriage vibrations

ISO INTERNATIONAL STANDARD

Transcription:

Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 150 (2016 ) 336 340 International Conference on Industrial Engineering, ICIE 2016 Study of the Oscillation Modes of a Coriolis Flowmeter Using a Parametric Finite Element Model, Verified by the Results of Modal Testing A.A. Yaushev a, *, P.A. Taranenko a, V.A. Loginovskiy b a South Ural State University, 76, Lenin Avenue, Chelyabinsk, 454080, The Russian Federation b Elmetro Grupp, Chelyabinsk, 454106, The Russian Federation Abstract The paper describes the calculated and experimental determination of the oscillation modes of a Coriolis flowmeter. To define the estimated parametric oscillation modes, we formed a model of the volumetric flowmeter finite element. The model allows the evaluation of the impact of changes in the meter size and the medium density on the flowmeter frequency. The results of the calculations of the finite element model were verified by modal tests of the flowmeter. 2016 The Authors. Published by by Elsevier Elsevier Ltd. Ltd. This is an open access article under the CC BY-NC-ND license Peer-review (http://creativecommons.org/licenses/by-nc-nd/4.0/). under responsibility of the organizing committee of ICIE 2016. Peer-review under responsibility of the organizing committee of ICIE 2016 Keywords: Coriolis flowmeter; finite element method; modal analysis; A Coriolis flowmeter is used to measure the mass flow of liquids and gases. It consists of a case and two U- shaped oscillating tubes through which the fluid is moving. The body of the flowmeter and its measuring part are shown in Fig. 1. The tubes make steady forced oscillations with a resonance frequency in the opposite direction to each other from the XY plane. The translatory motion of the fluid in the rotational motion around the X axis of the tube causes Coriolis acceleration and, thus, Coriolis force. This force is directed against the tube movement it gets from the coil, that is, when the tube moves along the Z-axis, the Coriolis force for the fluid flowing inside is directed against the Z-axis. As soon as the liquid passes the tube bend, the direction of the Coriolis force is reversed. The Coriolis force causes a phase shift, being proportional to the mass flow rate, for the mechanical oscillations of two measuring tubes taking place at measuring coil installation. * Corresponding author. Tel.: +7-351-272-37-44. E-mail address: iaushevaa@susu.ac.ru 1877-7058 2016 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Peer-review under responsibility of the organizing committee of ICIE 2016 doi:10.1016/j.proeng.2016.07.027

A.A. Yaushev et al. / Procedia Engineering 150 ( 2016 ) 336 340 337 A design overview of a Coriolis flowmeter is given in [1, 2], and a detailed description of the principle of operation is given in [3]. Fig. 1. Coriolis flowmeter: 1 process connection flange; 2 flow tubes; 3 current controller; 4 support; 5 measuring coils; 6 drive coil; 7 weights To understand the dynamics of mechanical systems is of great importance for the creation and improvement of new designs as well as for solving the problems associated with the mechanical vibrations of existing structures. An effective tool for studying the dynamic properties of the system is the modeling of the dynamic behavior of structures using the finite element method [4, 5]. Verification by mode test results is important for designing a finite element model [6, 7]. Using this model it is necessary to develop the flowmeter verification technology in site [8, 9]. Hence, to estimate the frequencies and modes of the flowmeter a finite volume model is formed (Fig. 2a). It consists of the elements of prismatic shape with twenty nodes and a tetrahedral shape with ten nodes. To determine the optimal size of the element, frequency calculations of flowmeter oscillations and forms for different sizes of elements were made. The dependence of the frequency of flowmeter oscillations on the number of nodes in the model, as the flowmeter operates, is shown in Fig. 2b. Fig. 2 Finite element model of flowmeter ( ); dependence of the frequency of flowmeter oscillations on the number of nodes (b) The accuracy of flow measurement is affected by the location of the flowmeter working frequency relative to other frequencies of the device parts. For example, in [10-13] the influence of the density of the medium measured, the tubes pressure and the geometric sizes of the flowmeter on its first frequency are considered. To assess the impact of the geometrical and technical parameters on the forms of flowmeter oscillations a finite element model, verified by modal test results, is appropriate. The generated finite element model is a parameterized one. To analyze the frequencies and modes of vibrations of the flowmeter the possibility to shift the support, and to change the mass of weights and the liquid density in tubes is provided. The weight mass varies due to changes in density of the materials used, and the density of fluid is changed by specifying the equivalent density of the tube material.

338 A.A. Yaushev et al. / Procedia Engineering 150 ( 2016 ) 336 340 Modal tests of the flowmeter [14, 15] were made by using the following hardware and software: LMS SCADAS a 40-channel measuring system for generating an excitation signal of vibrations, collecting and processing of dynamic signals; Spectral Testing module of software package LMS Test.Lab for modal testing and processing of the results; modal vibration shaker TMS2100E11; force sensor PCB 208C03 with sensitivity equal to 2,2 mv / N; three-piezoaccelerometers PCB 356A32 with the sensitivity of 100 mv / g; three-single-point Polytec CLV-3D laser vibrometer. The test configuration is shown in Fig. 3, 4. The flowmeter is freely suspended on elastic ropes. The broadband random excitation signal is generated by the computer in the range of 20 to 400 Hz with the help of the LMS Test Lab program. The excitation signal is formed on the LMS Scadas generator, transformed to an amplifier and then to the modal shaker. The shaker is suspended with rods and connected to the case base of the flowmeter. To control the forced oscillations between the flowmeter and shakers the force sensor is installed. The three-laser vibrometer [16] measures in a non-contact way three components of the vibration velocity of the tubes. Opposite all of the coils on both sides of the flowmeter case six holes are made for technical measurements. Case oscillations are measured using three-component accelerometers mounted on its surface. Fig. 3. Test configuration: 1 flowmeter; 2 laser vibrometer; 3 accelerometers; 4 SCADAS; 5 computer; 6 amplifier; 7 modal shaker; 8 force sensor; 9 rodes; 10 opening in the flowmeter for making measurements by laser vibrometer Fig. 4. Photos experimental stand

A.A. Yaushev et al. / Procedia Engineering 150 ( 2016 ) 336 340 339 When the modal shaker excited oscillations, we recorded the excitation signal with a force sensor, measured the vibration velocities of the point on the tube with the three-laser vibrometer, and measured the case vibration accelerations with accelerometers. Calculating the excitation signals and the responses we obtained the frequency transfer functions. Then, the experiment was repeated with a laser vibrometer measurement at another point. We used 6 points on the tubes for measurements. The averaged frequency transfer functions obtained were processed using a PolyMax algorithm [17, 18] and we identified the characteristic frequencies, the shape and the decrements of the flowmeter oscillations. In the frequency range under study, which is up to 400 Hz, we identified ten forms of natural vibrations of the tubes and three forms of the case vibrations. The forms of flowmeter oscillations, in the range less than 200 Hz, are of great practical value. The first natural frequency of the case oscillation is 236 Hz. The table 1 shows a comparison of the calculated and experimental forms and frequencies of natural oscillations of the flowmeter measuring tubes. The modal assurance criterion (MAC) is used to compare waveforms [18, 19]. Table 1. Comparison of the calculated and experimental forms and natural frequencies of the flowmeter tube oscillations Form Experiment Calculation Error Description of oscillation forms Frequency, Hz Frequency, Hz % 1 Antiphase oscillations of tubes in XY plane 88.8 91.9 3.5 0.93 2 Inphase oscillations of tubes in XY plane 94.0 95.5 1.6 0.87 3 Antiphase oscillations of tubes of the XY plane 116.8 117.4 0.5 0.79 4 Inphase oscillations of tubes in XY plane 128.6 126.8 1.4 0.76 5 Inphase oscillations of tubes in XY plane 157.4 162.4 3.2 0.91 6 Antiphase oscillations of tubes of the XY plane 174.7 175.4 0.4 0.97 The discrepancy between the calculated and experimental flowmeter frequencies does not exceed 4%, thus, the finite element model of the flowmeter reflects accurately the properties of the actual flowmeter design. Using the finite element model, we obtained for the first and six flowmeter frequencies the effect estimates for the support shifting, for changing both the mass of weights and liquid density placed in the tubes (Fig. 5). The frequency of forced vibrations coincides with the first natural frequency when using the flowmeter. The sixth form of natural vibrations is similar to a waveform of forced flowmeter of the Coriolis force. Fig. 5. Dependence of the first and second flowmeter frequencies on the flowmeter parameters With the use of the finite element model created it is possible to avoid an unacceptable coincidence of the flowmeter natural frequencies and the three harmonics frequency of the electrical network when creating a new and improved flowmeter. The results obtained from the verified finite element model allow a sufficiently high reliability

340 A.A. Yaushev et al. / Procedia Engineering 150 ( 2016 ) 336 340 in assessing the changes of flowmeter frequencies and, correspondingly, the flow measurement accuracy when changing the geometric dimensions and technical parameters of the flowmeter system. The experiments were carried out using the equipment center "Experimental Mechanics" SUSU. References [1] T. Wang, R. Baker, Coriolis flowmeters: a review of developments over the past 20 years, and an assessment of the state of the art and likely future directions, Flow Measurement and Instrumentation. 40 (2014) 99 123. [2] K.O. Plache, Measuring mass flow using the Coriolis principle, in: R. Loxton, P. Pope (eds.), Instrumentation: A Reader, Springer US, 1990, pp. 55 62. [3] H. Raszillier, F. Durst, Coriolis-effect in mass flow metering, Archive of Applied Mechanics. 3 (1991) 192 214. [4] L.J. Segerlind, Applied finite element analysis, 2nd edition, Wiley, New York, 1984. [5] K.J. Bathe, E.L. Wilson, Numerical Methods in Finite Element Analysis, New Jersey, Prentice-Hall, 1976. [6] J. Melcer, Experimental Verification of a Computing Model, Applied Mechanics & Materials. 732 (2014) 345 348. [7] V.S. Mezhin, V.V. Obukhov, The Practice of Using Modal Tests to Verify Finite Element Models of Rocket and Space Hardware, Space technics and technology. 4 (2014). [8] T.J. Cunningham, An In-Situ Verification Technology for Coriolis Flowmeters, Micro Motion. (2009) 5. [9] T.J. Cunningham, T. O`Banion, Allow Smart Meter Verifi cation to Reduce your Proving and Proof-Test Costs, Micro Motion. (2013). [10] J. Kutin, I. Bajsik, An analytical estimation of the Coriolis meter`s characteristics based on modal superposition, Flow Measurement and Instrumentation. 12 (2002) 345 351. [11] T. Wang, Pressure effects on Coriolis mass flowmeters, Flow Measurement and Instrumentation. 21 (2010) 504 510. [12] S. Guirguis, Modeling of Coriolis mass flow meter of a general plane-shape pipe, Flow Measurement and Instrumentation. 21 (2010) 40 47. [13] R. Cheesewright, S. Shaw, Uncertainties associated with finite element modeling of Coriolis mass flow meters, Flow Measurement and Instrumentation. 17 (2006) 335 347. [14] O. Dossing, Structural Testing, Part 1, Mechanical Mobility Measurements, Brüel & Kjæ, Denmark, 1989. [15] O. Dossing, Structural Testing, Part 2, Modal Analysis and Simulation, Brüel & Kjæ, Denmark, 1989. [16] CLV-3D Compact 3-D Laser Vibrometer, For Simultaneous 3-D Measurement of Dynamics, Polytec, 2010. [17] D.J. Ewins, Modal Testing: Theory, Practice and Application, Research Studies Press, Hertfordshire, 2000. [18] W. Heylen, S. Lammens, P. Sas, Modal Analysis Theory and Testing, Catholic University of Leuven, 1997. [19] R.J. Allemang, The Modal Assurance Criterion Twenty Years of Use and Abuse, University of Cincinnati, Sound and Vibration. (2003) 14 21.