arxiv: v1 [physics.ins-det] 18 Feb 2009

Similar documents
Cherenkov Detector Prototype for ILC Polarimetry

arxiv: v1 [physics.ins-det] 1 Apr 2009

Upstream Polarimetry with 4-Magnet Chicane

Simulation Studies for a Polarimeter at the International Linear Collider (ILC)

arxiv: v3 [physics.ins-det] 7 Oct 2009

The low Q 2 chicane and Compton polarimeter at the JLab EIC

Polarimetry. POSIPOL 2011 Beijing Peter Schuler (DESY) - Polarimetry

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

Synchrotron Radiation a Tool for Precise Beam Energy Measurements at the ILC

A Gaussian Fitter for the CESR-c Fast Luminosity Monitor

Upstream Polarimetry with 4-Magnet Chicane

PoS(PSTP 2013)034. Precession Polarimetry at JLab, 6 GeV. G.B. Franklin Carnegie Mellon University

Stathes D. Paganis Nevis Laboratories, Columbia University, Irvington NY, 10533, USA (On behalf of the ZEUS Collaboration)

The E166 Experiment: Undulator-Based Production of Polarized Positrons

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Forward Region, Energy Spectrometer, Polarimeter. Snowmass Klaus Mönig

CALICE Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006

Polarised Geant4 Applications at the ILC

Development of a Dedicated Hard X-Ray Polarimeter Mark L. McConnell, James R. Ledoux, John R. Macri, and James M. Ryan

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Linear Collider Beam Instrumentation Overview

Calorimeter test-beam results with APDs

Tests of the Burle anode MCP PMT as a detector of Cherenkov photons

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

- he [I+ P,P,A (~%)l,

A gas-filled calorimeter for high intensity beam environments

Test setup, APDs,, preamps Calibration procedure Gain monitoring with LED Beam test results Future R&D options

Introduction to polarimetry at HERA

Status report on parity violation in the (1232) resonance

PoS(PD07)031. General performance of the IceCube detector and the calibration results

Measuring very forward (backward) at the LHeC

EIC Electron Beam Polarimetry Workshop Summary

Electron Beam Polarimetry: Status and Prospects. DIS 2005, Madison, April 2005 E. Chudakov (JLab)

THE CERN NA62 experiment [1] aims to measure the

arxiv: v1 [physics.ins-det] 27 Jun 2017

A RICH Photon Detector Module with G-APDs

Particle Identification at a super B Factory. FRASCATI WORKSHOP DISCUSSION ON PID

arxiv: v1 [physics.ins-det] 22 Dec 2013

Hall A Compton Calorimeter G. B. Franklin Carnegie Mellon University

High Energy Photons at HI S

RICH detectors for LHCb

Performance of the MCP-PMT for the Belle II TOP counter

Detailed Characterization of Vacuum Chamber Surface Properties Using Measurements of the Time Dependence of Electron Cloud Development

E166: Polarized Positrons & Polarimetry

Measurement of Nucleon Strange Form Factors at High Q 2

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

Progress Report on the A4 Compton Backscattering Polarimeter

Status of the LHCb RICH and hadron particle identification

A4 Laser Compton polarimetry

Overview on Compton Polarimetry

The Compton backscattering Polarimeter of the A4 Experiment

The E166 Experiment: Undulator-Based Production of Polarized Positrons

PHYS 3650L - Modern Physics Laboratory

Luminosity measurements and diffractive physics in ATLAS

LEP 2 Energy Calibration and the Spectrometer

arxiv: v1 [physics.ins-det] 3 Feb 2011

Lucite Hodoscope for SANE

Toward 0.5% Electron Beam Polarimetry. Kent Paschke University of Virginia

EIC Electron Beam Polarimetry Workshop Summary

ATLAS Tile Calorimeter Calibration and Monitoring Systems

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

Timing and cross-talk properties of BURLE multi-channel MCP-PMTs

Simulation of Laser-wires at CLIC using BDSIM

Dual readout with tiles for calorimetry.

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Status of the CALICE analog calorimeter technological prototypes

Hybrid Avalanche Photo Detector for Belle II ARICH detector

P-Carbon CNI Polarimeter Operation Experience

arxiv:physics/ v1 3 Aug 2006

The EDM Polarimeter Development at COSY-Jülich

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

A Test Experiment for a Polarized Positron Source - E-166 at SLAC

PMT Charge Response and Reconstruction of Position and Energy for a Reactor θ 13 Experiment

HERA II Physics. Both ZEUS & H1 have made major upgrades in order to utilise the increase in HERA luminosity to the full.

Building a Tracking Detector for the P2 Experiment

AIRFLY: Measurement of the Air Fluorescence induced by electrons

ISPA-Tubes with YAP:Ce Active Windows for X and Gamma Ray Imaging.

Experiment 6 1. The Compton Effect Physics 2150 Experiment No. 6 University of Colorado

1 Introduction. KOPIO charged-particle vetos. K - RARE Meeting (Frascati) May Purpose of CPV: veto Kl

Gamma-Rays and Blowfish. What are we doing? Why are we doing it? How are we doing it?

Scintillation Detector

Top Quark Precision Physics at Linear Colliders

CALICE Test Beam Data and Hadronic Shower Models

arxiv: v2 [physics.ins-det] 8 Feb 2013

Luminosity Energy Polarization Status. Documentation Status of Linear Collider Beam Instrumentation Design, D. Cinabro, E. Torrence and M.

HARPO: Measurement of polarised gamma rays (1.7 to 72MeV) with the HARPO TPC

arxiv: v2 [nucl-ex] 6 Oct 2008

Study of GEM-TPC Performance in Magnetic Fields

A study of silicon sensor for ILD ECAL

GEM-based photon detector for RICH applications

SFB project B1: Jenny List DESY - Hamburg SFB Kolloquium Physics beyond the Standard Model at the ILC:

Neutron emission asymmetries from linearly polarized γ rays on nat Cd, nat Sn, and 181 Ta

Initial Studies in Proton Computed Tomography

GEANT4 simulation of the testbeam set-up for the ALFA detector

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

Status and Plans of the Large TPC Prototype for the ILC

PoS(ICHEP2016)293. The LArIAT experiment and the charged pion total interaction cross section results on liquid argon. Animesh Chatterjee

Magnetic fields of the optical matching devices used in the positron source of the ILC

The CTA SST-1M cherenkov telescope. for high-energy gamma-ray astronomy. and its SiPM-based camera. Victor Coco (DPNC, Universite de Geneve)

Transcription:

Compton Cherenkov Detector Development for ILC Polarimetry arxiv:92.3221v1 [physics.ins-det] 18 Feb 29 Christoph Bartels 1,2, Christian Helebrant 1,2, Daniela Käfer 1, and Jenny List 1 1- Deutsches Elektronen Synchrotron (DESY) - Hamburg, Germany 2- Universität Hamburg, Germany In order to fully exploit the physics potential of the ILC, it will be necessary to measure (and control) beam parameters to a permille level precision. In case of the beam polarisation, this can only be achieved with dedicated high energy Compton polarimeters and by improving the detector linearity, as well as the calibration of the analyzing power. This note summarises results of an early testbeam period with the Cherenkov detector of the SLD polarimeter, linearity measurements of readout electronics and photodetectors and compares simulation results of the SLD Cherenkov detector with those of a new U-shaped prototype. 1 Polarisation and precision The measurement and control of beam parameters to a permille level precision will play an important role in the ILC s ambitious physics programme [2, 3]. This means, not only the luminosity and the beam energy need to be measured precisely, but also the polarisation of the electron and positron beams have to determined with unprecedented accuracy. While this has already been achieved at previous colliders for beam energy measurements, the precision of polarisation measurements has to be improved by at least a factor of two compared to the up to now most precise polarisation measurement of the SLD polarimeter [5]. It is planned to achieve dp/p =.25% or better. The polarisation measurement at the ILC will combine the measurements of two dedicated Compton polarimeters, located upstream and downstream of the e + e interaction point, and data from the e + e annihilations themselves. While e + e annihilation data will finally (after several months) provide an absolute scale, the polarimeters allow for fast measurements and, in case of the upstream polarimeter, probably even resolve intra-train variations, give feedback to the machine, reduce systematic uncertainties and add redundancy to the entire system [4]. Circularly polarised laser light hits the e + (e )-beam under a small angle and typically in the order of 1 electrons are scattered per bunch. The energy spectrum of the scattered particles depends on the product of laser and beam polarisations, so that the measured rate asymmetry w.r.t. the(known) laser helicity is directly proportional to the beam polarisation. Since the electrons scattering angle in the laboratory frame is less than 1 µrad, a magnetic chicane is used to transform the energy spectrum into a spacial distribution and lead the electrons to the polarimeter s Cherenkov detector. It consists of staggered U-shaped aluminum tubes lining the tapered exit window of the beam pipe. The tubes are filled with the Cherenkov gas C 4 F 1 and are read out by photodetectors. Electrons traversing the basis of these U-shaped tubes generate Cherenkov radiation which is reflected upwards to the photodetectors [6]. The authors acknowledge the support by DFG Li 156/1-1. LCWS/ILC 28

Developing a Cherenkov detector suitable for achieving the aforementioned precision of dp/p =.25% demands improvements in various areas of the experimental setup. Of utmost importance, however, is the linearity of the detector response, or the ability to control and correct for a non-linear response. The following areas of work are briefly discussed: testbeam data analysis, linearity measurements of readout electronics and photodetectors (PDs), simulation and design of a new prototype detector. 2 Testbeam results In November and December 27, the SLD Cherenkov detector (Fig. 1) was set up in the DESY-II testbeam for two short periods of time. From different orientations of the detector, either using the Cherenkov drift section (indicated in red) or not (beam incident on the area indicated in blue), the reflectivity of the aluminum channels was measured to be about 9%. As can be seen from Fig. 1, the cross talk between adjacent channels is asymmetric with more Cherenkov photons detected in channels left of the one on which the beam is centered. 7 6 5 4 asymmetric crosstalk SLD-Kanal 6 SLD-Kanal 4 SLD-Kanal 5 3 2 1 1 2 3 4 5 Ladung [pc] Figure 1: The open SLD Cherenkov detector; different colours indicate different sections. Asymmetric cross talk in channels 4 and 6, while the beam is centered on channel 5. Further tests included a setup where some of the original photodetectors were exchanged for newer types, especially three multianode photomultipliers and also a new silicon-based photomultiplier. However, results from these measurements are not discussed here. 3 Linearity measurements of electronics and photodetectors A component test stand is used to study different types of photodetectors. They are set up in a light-tight box and read out via a high resolution double range 12-bit VME charge-todigital converter (QDC), with either 2 fc or 25 fc per LSB (least significant bit). A blue LED (λ = 472 nm) connected to a function generator is used to generate the light detected by the PD. Before testing the linearity of the PDs themselves, the differential and integral non-linearity (DNL, INL) of the QDC has also been measured. A ramp (f = 1 Hz) is used as input signal while the QDC is triggeredby a short random gate of 5 ns duration. The probability for each transition to occur at a certain QDC code bin is measured and compared to an ideal distribution. If the QDC was ideal, a uniform LCWS/ILC 28

distibution of code bins would be expected. The ratio between the measured and the ideal distribution is the code bin width, from which the DNL can be calculated as the deviation of the ideal code bin width of 1 LSB. The INL for a certain QDC code bin is then given by the sum of DNLs up to this bin. Both distributions are rather flat and a fit to the mid range of codes, from 2 to 8 QDC bins, gives an INL from 1 to 2 LSBs, corresponding to.1-.2% of the full scale range. The most extensive linearity studies have been performed on 2x2 multianode photomultipliers (MAPM, Hamamatsu R59U-M4). The spectrum of QDC counts is fitted by a modified Poisson function to determine the number of incident photoelectrons. The true number of photoelectrons expected for a certain amount of light cannot be determined since the relation between light yield and LED bias voltage is not calibrated. However, the method used to measure the PD s INL is independent of the absolute scale of the LED and only depends on the length of a rectangular pulse lighting the LED. Varying this pulse length ensures a linear variation of the amount of light on the photocathode of the PD. The pulse length is varied between 3 ns and 15 ns in steps of 5 ns. Figure 2 shows the results of several measurement series. As can be seen in Fig. 2, the correction is highly successful 1..5 -.5-1. 1..5 -.5-1. 1 15 2 25 3 35 1 st measurement reference 28-11-14--18:56 28-11-15--1:54 4 6 8 1 12 14 1 15 2 25 3 35 2 nd series corr. fails: NL.25% (c) 28-11-15--9:11 28-11-15--16:8 uncorrected corrected 4 6 8 1 12 14 N p.e 1..5 -.5-1. 2. 1.5 1..5 -.5-1. -1.5-2. 1 15 2 25 3 35 3 rd & 4 th series similar corr. successful: NL.1% 28-11-16--13:39 28-11-16--2:37 uncorrected corrected 4 6 8 1 12 14 time ordering (d) meas 1 meas 2 meas 3 meas 4 4 6 8 1 12 14 Figure 2: PD linearity measurements obtained using the pulse-length method: reference measurement, 2 nd and (c) 3 rd measurement series, corrected using the 1 st measurement. (d) The four measurement series ordered in time. for the 3 rd and 4 th measurement series with a resulting INL of less than.1%, but fails for the 2 nd measurement (Fig. 2(c)), where the INL is only about.25%. However, these results show that the PD non-linearity can be measured and thus controlled to a precision of.1%. A second method relying on optical filters will be used to cross check these results. LCWS/ILC 28

Another two methods were developed to measure the DNL: one measures the difference between the PD s response to the initial (variable) pulse P i and its response to the pulse P i +p with p being a very small fix pulse. For the second method, a 4-hole mask is applied to the PD so that the ratio of the sum of single pulses through each hole and one pulse through all four holes simultaneously gives the DNL. 4 Prototype simulation and design y [mm] 15 1 Illumination of SLD channel 7 IlluminationSLD7 Entries 581299 Mean x 32.4 Mean y -.6915 RMS x 4.888 RMS y 4.4 8 7 x [mm] 1 8 6 Illumination of TesBox channel 2 IlluminationTestbox2 Entries 47339 Mean x 79 Mean y -.254 RMS x 2.648 RMS y 2.596 8 7 5-5 -1 6 5 4 3 2 1 4 2-2 -4-6 -8 6 5 4 3 2 1-15 A smaller prototype has been simulated and constructed to study the entire Cherenkov detector design. This simplified version of the envisioned detector consists of only two U- shaped aluminum channels with a cross section of 8.5 mm 2 embedded in a box flooded with the Cherenkov gas C 4 F 1. The gas is non-flammable and was chosen mainly because of its high Cherenkov threshold of about 1 MeV. The electron beam will pass through the basis of the U-shaped channels, entering and exiting through thin aluminum windows, and produce Cherenkov photons which are then reflected towards a photodetector mounted on the hind U-leg. The front U-leg is solely for calibration purposes with two LEDs mounted there, one per channel. For the design of the prototype detector and also for the interpretation of future testbeam data, an optical simulation based on GEANT4 has been created. However, the PD response, i.e. mainly the PD s quantum efficiency is simulated separately using simple ROOT macros. Figure 3 shows a comparison between the simulated illumination of a single channel of the SLD detector and the new U-shaped prototype. The strong asymmetry visible for the SLD- 285 29 295 3 35 31 315 32 x [mm] -1 7 72 74 76 78 8 82 84 86 88 9 z [mm] Figure 3: Simulation of the illumination (light intensity) in a single channel for the SLD Cherenkov detector and the new prototype. type channel in Fig. 3 is avoided with the new design (Fig. 3), where only a slight inhomogeneity in the light intensity is seen. The reduction of cross talk and the avoidance of geometry-based asymmetries was the main reason to choose the peculiar U-shaped geometry for the prototype detector. An illumination scan with 4 4 points per channel and 1, electrons per shot leads to Fig. 4, where depicts the light yield on the PD anode for electrons entering the Cherenkov section at a fixed y position, but variable x position. (Due to the geometry, a certainz position onthe PDandodecorrespondsto acertainbeam positiony in the channels at the U-basis.) Figure 4(b,c) show the corresponding calculated asymmetries in the light intensity for scans in the x- and z-directions, respectively. LCWS/ILC 28

z fixed: 4 diff. graphs for 4 diff. x-positions good linearity! x fixed: 4 diff. graphs for 4 diff. z-positions good linearity! Figure 4: Illumination scan of a testbox channel with 1, e per shot. (b,c) Asymmetries calculated from the light intensity on the photocathode for different scans: A x+x for fixed z position and A z+z for fixed x position. (c) The photodetector mounting on the hind U-leg is realized exchangeably to enable the testing of several different PDs (and different read-out modes) within one setup. References [1] Presentation: http://ilcagenda.linearcollider.org/contributiondisplay.py?contribid=36&sessionid=13&confid=2628 [2] ILC Global Design Effort and World Wide Study, International Linear Collider Reference Design Report - Volume 2 and 3, August 27. [3] G.A. Moortgat-Pick et al., Phys. Rept. 46 (28) 131, [arxiv:hep-ph/5711]. [4] B. Aurand et al. ILC-NOTE-28-47, [arxiv:88.1638v1 physics.acc-ph]. [5] [ALEPH, DELPHI, L3, OPAL and SLD Collaborations], Phys. Rept. 427 (26) 257. [6] Presentation at the Workshop on Polarisation and Beam Energy Measurements, Zeuthen, April 28; https://indico.desy.de/contributiondisplay.py?contribid=22&sessionid=8&confid=585 [7] Presentation at the LCWS7: http://ilcagenda.linearcollider.org/contributiondisplay.py?contribid=172&sessionid=78&confid=1296 D. Käfer, O. Eyser, C. Helebrant, J. List and U. Velte, Proceedings of LCWS7 and ILC7, Hamburg, Germany, 3 May - 3 Jun 27, [arxiv:79.2683v1 physics.ins-det]. LCWS/ILC 28