Performance of Flocking-Based Control Schemes in Smart Grid Applications

Similar documents
Performance Evaluation of Flocking-Based Distributed Cyber-Physical Control for Smart Grid

A Game-Theoretic Control Approach to Mitigate Cyber Switching Attacks in Smart Grid Systems

A Smart Grid Vulnerability Analysis Framework for Coordinated Variable Structure Switching Attacks

SMART GRID systems employ advanced data acquisition,

IEEE TRANSACTIONS ON SMART GRID, VOL. 5, NO. 6, NOVEMBER

Coordinated Variable Structure Switching in Smart Power Systems: Attacks and Mitigation

1. Introduction. Keywords Transient Stability Analysis, Power System, Swing Equation, Three-Phase Fault, Fault Clearing Time

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II : 7 - Transient Stability

ECEN 667 Power System Stability Lecture 15: PIDs, Governors, Transient Stability Solutions

CURENT Course Power System Coherency and Model Reduction

Slow Coherency & Sparsity-Promoting Optimal Wide-Area Control

B.E. / B.Tech. Degree Examination, April / May 2010 Sixth Semester. Electrical and Electronics Engineering. EE 1352 Power System Analysis

Synchronization and Kron Reduction in Power Networks

PMU-Based Power System Real-Time Stability Monitoring. Chen-Ching Liu Boeing Distinguished Professor Director, ESI Center

Robust transient stability assessment of renewable power grids

Global Swing Instability in the New England Power Grid Model

Power Grid Partitioning: Static and Dynamic Approaches

Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics (Part 2)

The Mathematical Model of Power System with Static Var Compensator in Long Transmission Line

CHAPTER 2 DYNAMIC STABILITY MODEL OF THE POWER SYSTEM

Transient Stability Analysis of Single Machine Infinite Bus System by Numerical Methods

ECEN 667 Power System Stability Lecture 20: Oscillations, Small Signal Stability Analysis

POWER SYSTEM DYNAMIC STATE ESTIMATION and LOAD MODELING. Cem Bila

POWER SYSTEM STABILITY

Improving Transient Stability of Multi-Machine AC/DC Systems via Energy-Function Method

Generalized Injection Shift Factors and Application to Estimation of Power Flow Transients

Chapter 9: Transient Stability

Survey of Synchronization Part I: Kuramoto Oscillators

SCHOOL OF ELECTRICAL, MECHANICAL AND MECHATRONIC SYSTEMS. Transient Stability LECTURE NOTES SPRING SEMESTER, 2008

KINGS COLLEGE OF ENGINEERING Punalkulam

Cyber Attacks, Detection and Protection in Smart Grid State Estimation

1 Unified Power Flow Controller (UPFC)

QUESTION BANK ENGINEERS ACADEMY. Power Systems Power System Stability 1

Spectral Analysis of Synchronization in a Lossless Structure-Preserving Power Network Model

A Decoupling Based Direct Method for Power System Transient Stability Analysis

= V I = Bus Admittance Matrix. Chapter 6: Power Flow. Constructing Ybus. Example. Network Solution. Triangular factorization. Let

The Mathematical Model of Power System with Thyristor Controlled Series Capacitor in Long Transmission Line

Modeling of Hydraulic Turbine and Governor for Dynamic Studies of HPP

Geometry-based Estimation of Stability Region for A Class of Structure Preserving Power Grids

Graph-Theoretic Analysis of Power Systems

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous)

Impact of Model Detail of Synchronous Machines on Real-time Transient Stability Assessment

Power System Model Reduction. Fall 2014 CURENT Course

Joint Frequency Regulation and Economic Dispatch Using Limited Communication

Transient stability analysis and control of power systems with considering flux decay by energy function approach

A Generalized Hamiltonian Model for Power System Dynamics with Relay Action. Raja Timihiri. Project Advisor: Christopher DeMarco

A Study on Fluctuations in Electromechanical Oscillation Frequencies of Power Systems

SPEED-GRADIENT-BASED CONTROL OF POWER NETWORK: CASE STUDY

ECE 585 Power System Stability

Role of Synchronized Measurements In Operation of Smart Grids

Adaptive under frequency load shedding using synchrophasor measurement

Impact of Photovoltaic Generation On The Power System Stability

Understanding Load Flow Studies by using PSAT

Minimax Approximation Synthesis in PSS Design by Embedding

URTDSM Initiative in India and Controlled Islanding using PMU Measurements

EE2351 POWER SYSTEM ANALYSIS UNIT I: INTRODUCTION

Location-Dependent Impacts of Resource Inertia on Power System Oscillations

Dynamic simulation of a five-bus system

Torques 1.0 Two torques We have written the swing equation where speed is in rad/sec as:

11.1 Power System Stability Overview

DESIGN OF POWER SYSTEM STABILIZER USING FUZZY BASED SLIDING MODE CONTROL TECHNIQUE

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II : 8 - Voltage Stability

Reliability of Bulk Power Systems (cont d)

Power Angle & Time Domain Plots 1.0 The power-angle curves

ANALYSIS OF SUBSYNCHRONOUS RESONANCE EFFECT IN SERIES COMPENSATED LINE WITH BOOSTER TRANSFORMER

Wide-Area Monitoring and Control of WECC Transfer Paths Using Real-Time Digital Simulations. Annual Project Report October 21, 2013

Real Time Control of Electrical Distribution Grids

QFT Based Controller Design of Thyristor-Controlled Phase Shifter for Power System Stability Enhancement

Final Exam, Second Semester: 2015/2016 Electrical Engineering Department

Online Dynamic Security Assessment Using Phasor Measurement Unit and. Forecasted Load. Qiushi Wang

Predicting, controlling and damping inter-area mode oscillations in Power Systems including Wind Parks

SUPPLEMENTARY INFORMATION

EVALUATION OF THE IMPACT OF POWER SECTOR REFORM ON THE NIGERIA POWER SYSTEM TRANSIENT STABILITY

A graph-theoretical characterization of power network vulnerabilities

Project Samples I. Outline. Power Grids as Prototypical Complex Networks. Project Samples II. Cyber-physical security

Identification of Destabilizing Attacks in Power Systems

Transient Stability Improvement of a Multi- Machine Power System by Using Superconducting Fault Current Limiters

WIDE AREA CONTROL THROUGH AGGREGATION OF POWER SYSTEMS

A STATIC AND DYNAMIC TECHNIQUE CONTINGENCY RANKING ANALYSIS IN VOLTAGE STABILITY ASSESSMENT

Cascading Outages in Power Systems. Rui Yao

Distributed Fault Detection for Interconnected Second-Order Systems with Applications to Power Networks

Power system modelling under the phasor approximation

THE UNIVERSITY OF NEW SOUTH WALES. School of Electrical Engineering & Telecommunications FINALEXAMINATION. Session

REAL-TIME TRANSIENT STABILITY ASSESSMENT

Module 3 : Sequence Components and Fault Analysis

CHAPTER 3 MATHEMATICAL MODELING OF HYDEL AND STEAM POWER SYSTEMS CONSIDERING GT DYNAMICS

A Framework for Robust Assessment of Power Grid Stability and Resiliency

Behavior of Power System Equilibrium Points in Dynamic Available Transfer Capability Calculation

IJSER. 1. Introduction

DYNAMIC RESPONSE OF A GROUP OF SYNCHRONOUS GENERATORS FOLLOWING DISTURBANCES IN DISTRIBUTION GRID

Voltage Stability Monitoring using a Modified Thevenin Impedance

The Operation of a Generator on Infinite Busbars

max clear Figure 1 below illustrates a stable case. P post (f) (g) (e) A 2 (d) (c)

UNIVERSIDAD DE CASTILLA-LA MANCHA

Frequency and Damping Characteristics of Generators in Power Systems

Synchronization and Transient Stability in Power Networks and Non-Uniform Kuramoto Oscillators

Critical clearing time evaluation of Nigerian 330kV transmission system

Nonlinear Control Design of Series FACTS Devices for Damping Power System Oscillation

Distributed Stability Analysis and Control of Dynamic Networks

MODELLING AND SIMULATION OF NONLINEAR INTERCONNECTED LARGE-SCALE SYSTEMS

Transcription:

Performance of Flocking-Based Control Schemes in Smart Grid Applications Abdallah K. Farraj Eman M. Hammad Jin Wei Deepa Kundur Karen L. Butler-Purry Department of Electrical and Computer Engineering, University of Toronto, Toronto, Ontario, Canada Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas, USA Email: {abdallah, ehammad, jinwei, dkundur}@ece.utoronto.ca, klbutler@tamu.edu Abstract Flocking control has recently been used in smart grid applications to stabilize power systems during a transient instability period. Based on consensus and cooperation of multiagent control systems, flocking control uses cyber information about the power system to help achieve stability after the occurrence of a fault in the power system. Recent work showed that such controller can be useful in a smart power grid; however, issues of the controller s power usage, stability time, and frequency deviation have not been investigated yet. This paper investigates the effect of the power generators inertia on these issues in a WECC 3-generator power system. Results of this work show that the location of the fault affects the relationship between the generators inertia and the investigated measures. I. INTRODUCTION Interest in smart grid systems has surged recently. Smart grid systems use advanced control, communications, and sensor technologies to improve the efficiency and resilience of the power grid. Further, smart grid technologies can help utility companies to better manage and control the energy resources and meet the customers demand. In addition, the increasing integration of renewable energy sources and storage units into the power grid accelerates the interest of adopting smart grid technologies. The cyber assets of a smart grid include communication and information technology infrastructures, computing systems, and data storage units. Cyber data can be collected over the power grid using phasor measurements units (PMUs) and remote terminal units (RTUs); this data can be transferred, as an example, to supervisory control and data acquisition (SCADA) systems using fiber optics communication links. The timely availability of the system s cyber data can help a control center better stabilize the power system. A flocking-based control is a nonlinear control that is based on consensus and cooperation of multi-agent control systems. In general, a flocking scheme can be used to control flockmates (or agents) to achieve [], [2]: flock centering where an agent stays close to nearby agents; collision avoidance where an agent avoids colliding with nearby agents; and velocity matching where an agent attempts to match the speed of nearby agents. For a power system application, the flock centring feature can be used to achieve phase angle cohesiveness while the velocity matching feature can be used to achieve frequency synchronization between the generators of the power system. A recent work in [3] [6] employed the concepts of flocking control to aid the generators achieve stability during a transient instability period. The proposed flocking controller employs the cyber information about the system into a nonlinear controller to help the power system achieve stability after the occurrence of a fault in the power grid. A local controller is used for each generator, and an external, fast-acting, power source is employed by each controller. The goal of the controller is to achieve frequency stability and phase cohesiveness when the power system undergoes a transient instability. Although the work of [3] [7] shed a light on the application of flocking control for smart grids, the impact of having different generators parameters on the performance of the controller was not investigated. Further, some performance measures were not considered. For example, the stability time of the system generators, the average power used by the controller, and the frequency deviation of the generators have not been investigated yet. This paper investigates the performance of the flocking control in a smart grid application. Specifically, this work explores the effect of the inertia of the power generators on the power usage, stability time, and average frequency for a WECC 3-generator power system. The rest of this paper is organized as follows. System model is shown in Section II. Section III investigates the performance of the flocking control. Conclusions and final remarks are shown in Section IV. II. SYSTEM MODEL Flocking-based control can be used to achieve transient stability in case of a fault in the power system. In this setup, a local controller is used for each generator and an external power source is employed by each controller. A schematic of the WECC 3-generator power system is shown in Fig.. In this power system, Bus is the slack bus, Buses 2 and 3 are PV buses, and Buses 7 and 8 are PQ (load) buses. The parameters of the power system s generators are shown in Table I, where and D i are expressed in seconds, δ i is expressed in radians per second, and the rest are expressed in per units. The swing equation links the system parameters in a differential equation, and it can be used to study the transient 978--4799-7088-9/4/$3.00 4 IEEE 233

!!" "!!! "! " " &%$$$! &!%&' & ' ( '! ' ( ) $ % "%*$(!%""'' ) $ "!%$&&& ( '" ( ' & (!%&"! Fig.. WECC power system model * $ % *!%' &%' &!%&( $ stability of a power system. Further, during the transient instability duration, the system parameters can be considered constant. Consequently, a swing equation with time-invariant parameters can be used to model the power system dynamics during the transient instability period. Parameter E i P e,i P m,i D i δ i ω i X di G ii Description internal voltage of Generator i, i =,...,N electrical power of Generator i mechanical power of Generator i inertia of Generator i damping constant of Generator i rotor angle of Generator i relative normalized rotor frequency of Generator i direct-axis transient reactance of Generator i equivalent shunt conductance of Generator i TABLE I SYSTEM PARAMETERS Let δi and ω i denote the derivatives of δ i and ω i with respect to time, respectively, then the swing equation of an interconnected power system is expressed as [8], [9] ω i + (P m,i P e,i ), where the electrical power of Generator i is defined as P e,i = E i E k [G ik cos(δ i δ k )+B ik sin(δ i δ k )], k= (2) where N is the number of generators in the power system, G ik = G ki 0 is the Kron-reduced equivalent conductance between Generators i and k, B ik = B ki > 0 is the Kronreduced equivalent susceptance between Generators i and k, and Y ik = G ik + B ik is the Kron-reduced equivalent admittance between Generatorsi and k. All of Y ik, G ik, and B ik ) are expressed in per unit values. Using φ ik = arctan( Gik B ik and P ik = E i E k Y ik, then the swing equation is reduced into ( ) ω i + M Pm,i i E i 2 G ii (3) P ik sin(δ i δ k +φ ik ). k=,k i () 8 6 4 2 0 2 4 Generator Generator 2 Generator 3 0 5 5 Time (sec) Fig. 2. Relative normalized frequency of the system generators Without a governor control, as described in Eqs. () and (3), the generators cannot stabilize the power system whenever there is a fault in any bus in the system. However, using external controllers can help stabilize the power system during the transient instability period. Applying an external power at Generator i, termed as U i, changes the swing equation into ( ) ω i + M Pm,i i E i 2 G ii P ik sin(δ i δ k +φ ik )+ U i. k=,k i In a flocking-based control, U i can be used to achieve both frequency synchronization and phase cohesiveness between the system generators. Specifically, U i is calculated as [3] t U = Gδ Bω D c(δ δ 0 ), (5) k= k i t 0 ρ(δ i δ k )dt where U = [U,U 2,...,U N ] T, t 0 is the time to activate the flocking control, t is the time to calculate the value of the control, ρ is a control function, c is a navigation term, δ 0 = [δ 0,δ 02,...,δ 0N ] T are the phase values at t 0, D = [D,D 2,...,D N ] T, δ = [δ,δ 2,...,δ N ] T, and ω = [ω,ω 2,...,ω N ] T. Moreover, B and G are cyber control matrices. It is noted that the model of the local generators does not include a governor control. The presence of a governor controller helps the generator during the instability duration; however, the governor control is much slower than the flocking controller. Consequently, it is believed that if the flocking controller stabilizes the system without the governor control, the power system will also be stable when the governor control is activated. III. EVALUATION OF FLOCKING CONTROL The impact of the generators inertia on the flocking controller s performance is investigated in this section. Specifically, the stability time and the average frequency of the power system s generators, and the average external power needed by the controller are considered. The WECC 3-generator test system is simulated to demonstrate the effectiveness of the flocking control. (4) 234

Stability time of Generator (b) M 3 = msec Average power of U (b) M 3 = msec M (d) M 3 = msec Stability time of Generator 2 M (d) M 3 = msec Average power of U 2 M (f) M 3 = msec Stability time of Generator 3 M (f) M 3 = msec Average power of U 3 Fig. 3. Stability time of the system generators Fig. 4. Average external power needed by the flocking controller As shown in Fig., N = 3 for the 3-generator power system. Let D = 0.005 seconds, D 2 = 0.00 seconds, D 3 = 0.002 seconds, X d = 0.08 pu, X d2 = 8 pu, and X d3 = 2 pu. The value of is varied between 5 to 75 msec, is varied between 2.5 to 25 msec, and the value of M 3 is alternated between 25 and msec. Running the load flow analysis for the power system before the fault occurs yields E =.62 7.605, E 2 =.26 8.904, and E 3 =.244 4.024. Because the power system is balanced and there are no transients before the fault, the mechanical power for each generator equals its electrical power. Consequently, using Eq. (2), the values of the mechanical power for each generator, in per unit values, are P m, =.9989, P m,2 = 66, and P m,3 =.6. The power system is assumed to be running normally from t = 0 to t = 0.5 seconds. However, a 3-phase fault occurs at Bus 6 at t = 0.5 seconds. Then, Line 6-7 is tripped out to clear the fault at t = seconds. Finally, the flocking controller is activated on all generators from t = 0.7 seconds to t = seconds. Stability time of a generator is found by finding the time after which the relative normalized frequency of the generator is restricted to some threshold (called stability margin). For = msec, = 5 msec, and M 3 = 35 msec, Fig. 2 displays the relative normalized frequency of the three generators. It is noted that when the stability margin is set to, the three generators need slightly more than 6 seconds to stabilize. Stability time results of the three generators are shown in Fig. 3. It is noted that the stability time increases with increasing the inertia of Generator 2. Moreover, when M 3 increases, the stability time is expected to increase as well. For Generator (the slack generator), the stability time decreases with increasing the inertia up to a point, then the stability time levels off (or increases slightly). The simulation results show that the lowest stability times are 9.27 seconds for Generator (when = 45 msec, = 2.5 msec, and M 3 = 25 msec); 8.75 seconds for Generator 2 (when = 45 msec, = 2.5 msec, andm 3 = 25 msec); and 9.07 seconds for Generator 3 (when = msec, = 2.5 msec, and M 3 = 25 msec). However, the flocking controller cannot stabilize the power system in some cases within the -second run. Specifically, for low values of and high values of and M 3, the power system appears slower in 235

5 5 M 3 = 25 msec M 3 = msec Generator 3.08% 5.39% Generator 2 3.08% 4.62% Generator 3 3.08% 9.23% TABLE II PERCENTAGE OF CASES WHERE THE GENERATOR IS NOT STABILIZED (b) M 3 = msec Frequency of Generator M 3 = 25 msec M 3 = msec Generator 89.3933 Generator 2 0.354 0.3 Generator 3 608 0.5704 TABLE III AVERAGE EXTERNAL CONTROL POWER (PU) 5 5 5 Frequency of Generator 2 5 (d) M 3 = msec Frequency of Generator 3 (f) M 3 = msec Fig. 5. Relative normalized frequency of the system generators responding to the flocking controller. With doubling the inertia of Generator 3, the number of cases that the generators in the power system cannot be stabilized increases as seen in Table II. The flocking control relies on external power sources (U i, where i =,...,N) to stabilize the power system as shown in Eq. (4). The value of U is calculated according to Eq. (5). Fig. 4 displays the average external power needed by the flocking controller during the time when the controllers are activated. It is observed that with increasing, the controller needs more power to stabilize Generator and less power to stabilize Generator 3. On the other hand, increasing the inertia of Generator 2 causes the flocking controller to use more external power for the three generators (the increase is less obvious for Generator 3). Further, Table III shows some results for M 3, where an increase in inertia means more external power is needed to stabilize Generator 3 and less power to stabilize Generator. Finally, Fig. 5 shows the average relative normalized frequency of the system s generators during the controllers active time. One goal of the flocking control is to achieve exponential frequency synchronization through lim ω i (t) = 0. Conset M 3 = 25 msec M 3 = msec Generator 0.0799 0.045 Generator 2 0.0933 0.0493 Generator 3 47 0.0429 TABLE IV AVERAGE RELATIVE NORMALIZED FREQUENCY (PU) quently, it is preferred that the relative normalized frequency of the system generators be as close as possible to zero. As the value of increases, the average values of ω and ω 3 increase. However, increasing the value of decreases the average values of the frequency. Further, Table IV shows the relationship between M 3 and the average frequency. When the value of M 3 is increased, both average values of ω and ω 2 decrease. It is observed that the location of the 3-phase fault and the tripped out line (i.e., Line 6-7) affects the way the generators respond to the flocking control. Specifically, it is shown that the inertia of Generator 3 (with its close proximity to Line 6-7) has the most effect on the stability time of the generators of the power system. IV. CONCLUSIONS Flocking control was recently proposed to help achieve transient stability after the occurrence of a fault in the power system. This paper investigates performance aspects of flocking-based control for power systems. Specifically, this work explores the relation between the inertia of the system generators and the stability time, the external control power, and the system frequency. Results of this work show that the location of the fault affects the way the flocking controllers perform. Further, the value of the inertia of the generator that is closest to the faulted line has the most impact on the performance of the controller. ACKNOWLEDGMENT This work was supported by the Natural Sciences and Engineering Research Council of Canada and the U.S. National Science Foundation under grant ECCS-28246. The authors acknowledge the contributions of Blas Sanchez in preparing the simulation environment. 236

REFERENCES [] C. W. Reynolds, Flocks, Herds, and Schools: A Distributed Behavioral Model, in Annual Conference on Computer Graphics and Interactive Techniques Computer Graphics, vol. 2, pp. 25 34, July 987. [2] R. Olfati-Saber, Flocking for Multi-Agent Dynamic Systems: Algorithms and Theory, IEEE Transactions on Automatic Control, vol. 5, pp. 4, March 06. [3] J. Wei, D. Kundur, T. Zourntos, and K. L. Butler-Purry, A Flocking- Based Dynamical Systems Paradigm for Smart Power System Analysis, in IEEE Power and Energy Society General Meeting (PESGM), pp. 8, 2. [4] J. Wei and D. Kundur, Two-Tier Hierarchical Cyber-Physical Security Analysis Framework For Smart Grid, in IEEE Power and Energy Society General Meeting (PESGM), pp. 5, 2. [5] J. Wei, D. Kundur, and T. Zourntos, On the Use of Cyber-Physical Hierarchy for Smart Grid Security and Efficient Control, in IEEE Canadian Conference on Electrical and Computer Engineering (CCECE), pp. 6, 2. [6] J. Wei, D. Kundur, T. Zourntos, and K. L. Butler-Purry, Probing the Telltale Physics: Towards a Cyber-Physical Protocol to Mitigate Information Corruption in Smart Grid Systems, in IEEE International Conference on Smart Grid Communications (SmartGridComm), pp. 372 377, 2. [7] A. K. Farraj, E. M. Hammad, J. Wei, D. Kundur, and K. L. Butler-Purry, Performance Evaluation of Flocking-Based Distributed Cyber-Physical Control for Smart Grid, in IEEE International Conference on Smart Grid Communications (SmartGridComm), pp. 6, 4. [8] F. Dörfler and F. Bullo, Synchronization and Transient Stability in Power Networks and Non-Uniform Kuramoto Oscillators, in American Control Conference (ACC), pp. 9 937,. [9] P. M. Anderson and A. A. Fouad, Power System Control and Stability. IEEE Power Systems Engineering Series, Piscataway, NJ: IEEE Press, 994. 237