Antistatic One-touch Fittings. Packing. Can be used for a wide range of pressures from low vacuum up to a pressure of 1.0MPa.

Similar documents
Body (Black) O-ring Stud. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent).

Body (Black) O-ring. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent).

Inch Size Uni One-touch Fittings. Applicable Tubing. Tubing material. Specifications. Fluid Note 3)

Clean One-touch Fittings

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2

Nickel-Plated Brass Push-In Fittings - NPTF/INCH

45 Flare Fittings. Copper Flare Bonnets and Gaskets. Copper Flare. Copper Flare Gaskets. * C Dimension: Copper Flare Seal Bonnet +/ 1/64

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.

Series SQ. Tube/Metric, Thread/M, Rc(PT) Structures D - 4

PN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings

Low Profile Slide Table

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way compact solenoid valves Type EV210A

General-purpose Multi-Contact Circular Waterproof Connectors

Solenoid valves 2/2-way direct-operated type EV210A

Imformation of C091D series

Connector~Tech Providing Harsh Environment Connector

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

Quick - connects. SQC Series, SFQC Series

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

MINIATURE MICROSWITCHES - PREMIUM

CS Series. Capacitance Type. Type. Proximity Sensor. Features

Pressure transmitters for industrial applications MBS 32 and MBS 33

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

1.1. Operating Parameters:

Series MHY2/MHW Angular Gripper. Cam actuation style is now standardized! MHZ2 MHZJ2 MHQ MHL2 MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ 2.

Installation guide 862 MIT / MIR

HARTING D-Sub Selection Guide

High Power Contacts - Up to 850A

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

ED 701 General Industry Pressure Transmitter

Thermal-Magnetic Circuit Breaker 2210-S2..

MINIATURE MICROSWITCHES - PREMIUM

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

BINOCULAR STEREOSCOPIC MICROSCOPE MBS-10. User Manual

Free Mount Cylinder Double Acting, Double Rod. ø6, ø10, ø16, ø20, ø25, ø32. How to Order. Action. D Double acting. Standard stroke (mm)

CF (Conflat Flange) Fittings - Adapters. (505)

microswitches Low force

Fluoropolymer Fittings Hyper Fitting

American Zettler AZ742 RELAY Datasheet

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.

Submittal Package PEX Press Fittings with Attached Sleeves For Use with Viega PureFlow Tubing

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size A DIN EN

Viega PureFlow Press Zero Lead Fittings with Attached Sleeves For Use with Viega PureFlow PEX Tubing. Potable Water. Residential Fire Sprinkler.

Cooling Water Flow Regulator

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

CDS. high density spring connection

Commercial Generator Parts Catalog. PROTEC Series

MR medium rating busbar

Thermal-Magnetic Circuit Breaker 2210-S2..

K04 TYPE -40 C +85 C 20000H

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore.

KM-70 Panel-mounting Thermostat

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

Rotary Switches AC09, 16 and 32

Thermal-Magnetic Circuit Breaker 2210-S2..

Flow Switches. Liquid Flow Switches. McDonnell & Miller. Mounting Methods

Amphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors.

Viega PEX Press Zero Lead Fittings with Attached Sleeves For Use with Viega PureFlow Tubing. Potable Water. Residential Fire Sprinkler.

180 Angular Gripper. Series MHY2/MHW2. Cam actuation style is now standardised! 5-241

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

GB-distribution boxes and enclosures

G-FIRE GROOVED FITTINGS

KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3


SUBMINIATURE MICROSWITCHES - PREMIUM

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

COPAL ELECTRONICS. F T T V 5 k Ω ( ) SINGLE TURN CERMET TRIMMERS FEATURES PART NUMBER DESIGNATION

WIREWAY & TROUGH. Lay-In Type 12 Wireway... WWY 1-2. Feed-Through Type 12 Wireway... WWY 3-4. Hinge/Screw Cover Wiring Trough...

ProPress (304 FKM) 1.3

VD1 CLC. Small Valves DIN-range with a higher k v -value

8D Series Common Section

Chapter 6. Losses due to Fluid Friction

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

90/10 COPPER NICKEL ALLOY EUCARO 10 OFFSHORE APPLICATIONS

Quick Guide KSAT. At a glance how it works

Operating Instructions for Digital Manometer. Model: MAN-SD

Part /Assy Parts List. Production Order. Badge, Perkins/Sabre M215C. Description

Odor Removal Filter Series AMF

AIR BREATHER FILTERS. Temperature from -25 to +100 C

Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230. KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 KTY 16-6

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar

Ÿ 9-50-way std density Ÿ way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g.

Surface-mounting Thermostats ATH Type Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Guidelines for the Installation of SYGEF Pipes, Fittings and Valves

RIGID PVC CONDUIT FITTINGS AND ACCESSORIES

VISUAL LEVEL INDICATORS

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

PVC - WHITE PRESSURE FITTINGS PRODUCTS PRICE LIST INCLUDES: PVC SCHEDULE 40, CLASS 125, POOL/SPA, LASCOTITE, ULTRAFIX REPAIR COUPLINGS PRICE GROUP

How to Order M9BW. Action D Double acting. Load voltage M9NWV M9NW 5 V, 12 V 5 V, 24 V 12 V M9BWV M9BW 12 V 12 V M9NAV M9NA 5 V, 12 V 12 V.

Amphenol. BACKSHELLS For LJT, RNJ, RNJ LP, JT, TV-CTV, SC39 AND SJT connectors. For MIL-DTL series I,II,III and VG96912 connectors

Peltier Application Note

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Module 3 - Thermodynamics. Thermodynamics. Measuring Temperatures. Temperature and Thermal Equilibrium

Transcription:

Antistatic One-touch Fittings Series KA One-touch loading and unloading Possible to use in vacuum (ax. 0kPa) Can be used in copper-free application Flame resistance (UL- standard, V-0) Surface resistance to 7 Ω Conductive resin is used for body and seals in fittings and tubing. Packing Can be used for a wide range of pressures from low vacuum up to a pressure of 1.0Pa. The use of a special profile ensures sealing and reduces resistance when the tube is inserted. Body O ring Stud when piping in a confined space. The body and threaded portion can turn. Gasket Chuck as large retension force Collet Guide Tube Release button (Black) Small disconnecting force. When the fitting is removed, the chuck and collet are released, thus preventing them from biting into the tube. Applicable Tubing Tube material Antistatic soft, ø, ø, ø, ø, ø, ø Component aterials Body C0BD, PBT Stud C0BD Chuck SUS0 Guide SUS0, C0BD, PBT Collet, Release button PBT Packing, O ring NBR C0BD is all electroless nickel plated. PBT parts have conductive ( to 7 Ω) and fire resistant applications. (UL-standard, V-O) Conductive NBR ( to 7 Ω) is used for packing Specifications Fluid ax. operating pressure ax. operating vacuum pressure Proof pressure Ambient and fluid temperature Thread Sealant (Thread portion) Copper-free application Surface resistance Air 1.0Pa 0kPa.0Pa 0 to 0 C JISB020, class2 (etric coarse screw thread) Gasket All brass parts electroless nickel plated to 7 Ω 7-10

Antistatic One-touch Fittings Series KA ale connector: KA <, > thread thread KA- 7 1 2.1 KA-.. 1. 2. 1 KA-U01.. KA0-. 1 1 2 KA0-. 1 KA0-U01 1. 1.. 1 KA0-U02 1 1.. KA0-. 1 1 KA0-1 1 KA0-U01 1. 1. 1 KA0-U02 1 1 1.1 1.1 KA0-U0.. 1 1 KA0-U01 2 20. 1 1 KA0-U02 1. 1. 1.0 1.0 KA0-U0 1. 1. 1 KA-U01 2 1 KA-U02 2. 2. KA-U0 2 1 1 1 2 KA-U0 1 2 1 KA-U02 0. 2. 1 KA-U0 1 2. 1..1.1 1 1 2 KA-U0 2. 1. 2 Reference dimensions after installation. ød L area <, > ale elbow: KAL <, > thread thread KAL- 1 1 KAL-.. 1. 1.. 2. 7 1 KAL-U01 1. KAL0-1. 1.. KAL0-. 1 1 1 1 KAL0-U01 20 20..2.2 1 KAL0-U02 1. 1 KAL0-1 1.. KAL0-1. 1 KAL0-U01. 20.. 1 KAL0-U02 1.. 1 KAL0-U0 2 2. 1 KAL0-U01. 2. 1 KAL0-U02 1 1.2 2. 2 1. 1. 1 KAL0-U0 2. 2 1 KAL-U01 2 2. 1. 1. 2 1 KAL-U02 2. 0 2. KAL-U0 0. 2.0 2.0 2 1 2 KAL-U0 0 1. 1 KAL-U02 1. KAL-U0 2. 2 2..7.7 1 2 KAL-U0 1. Reference dimensions after installation. area <, > Precautions Caution qfemale thread portion connected with fitting must be grounded, or fitting and tubing will have static electricity. 7-

Series KA ale branch tee: KAT <, > thread thread KAT- 1 1 KAT-.. 1. 1.. 2. 1 KAT-U01 1. KAT0-1... KAT0-. 1 1 1 1 KAT0-U01 20..0.0 1 KAT0-U02 1 1 KAT0-1 KAT0-1. 1.. 7 1 KAT0-U01. 20.. 1 KAT0-U02 1 1. 1. 1 KAT0-U0 2 2. 2 1 KAT0-U01. 1 2 1 KAT0-U02 1 1.2 2. 1.2 1.2 1 KAT0-U0 2. 1 KAT-U01 2 2. 0 1 KAT-U02 2. 0 2. 2.0 2.0 KAT-U0 0. 1 1 2 KAT-U0 0 1. 1 1 KAT-U02 1. 1 KAT-U0 2. 2 2..2.2 1 2 KAT-U0 1. Reference dimensions after installation. area <, > ale run tee: KAY <, > thread thread KAY- 1 2. KAY-.. 1. 1.. 2. 1 KAY-U01 1. KAY0-1 1. 2... KAY0-. 1 1 1 KAY0-U01 20 1.. 1 KAY0-U02 1. 1 KAY0-20 1 KAY0-20. 1. 2.. 1 KAY0-U01.. 7. 1 KAY0-U02 1 20 7 1. 1. 1 KAY0-U0 2 2 1 KAY0-U01. 1 1. 1 KAY0-U02 1 1.2 2..7.7 1 KAY0-U0 2. 2. 1 KAY-U01 2. 0 1 KAY-U02 2. 7. 2. 2. 2. KAY-U0 1 1 2 KAY-U0 0 1 1 KAY-U02. 1 KAY-U0 2. 2 0... 1 2 KAY-U0 1 1. Reference dimensions after installation. area <, > 7-

Antistatic One-touch Fittings Series KA Branch: KAU <, > thread thread ød L KAU- 2.2 2.2 KAU-... 1.. 1 KAU-U01. 2. KAU0-. 2.2 2.2 KAU0-. 0. 1 1 KAU0-U01.2.2 1 KAU0-U02 1 2 1 KAU0-2. KAU0-1 2.2 2.2 1 KAU0-U01.... 1 1 KAU0-U02 1 1. 1. KAU0-U0 0 2 1 1 KAU0-U01 KAU0-U02 1.2 0. 2 1.2..7.7 2 2 KAU0-U0 1.. 1 KAU-U02 1 KAU-U0 7. 1. 2. 2. 1 2 KAU-U0 1 1 1 KAU-U02 1 KAU-U0.. 2 1 2 KAU-U0 2.. 2 Reference dimensions after installation. P area <, > Straight union: KA ød L KA-00. 1. 1.. 2. KA0-00. 2. 1.. KA0-00.. 1.1 1.1 KA0-00 KA-00 KA-00 1.2. 2.. 1.0 2..1 1.0 2..1 1 Different diameter straight: KA ød L 1 2 KA-0. 2. 1. 1 2.7 KA0-0.. 1.2.2 KA0-0 1.2..7.7 KA0- KA- 2. 1.7 2.2 1.7 2.2 1 7-1

Series KA Union elbow: KAL ød L Q KAL-00... 1.. 2. KAL0-00. 1. 1.2.2 KAL0-00. 20... KAL0-00 KAL-00 KAL-00 1.2 2. 2.. 7. 1. 2.0.7 1. 2.0.7 Branch tee: KAT ød L Q KAT-00... 1.. 2. KAT0-00. 1. 1.. KAT0-00. 20. 1. 1. KAT0-00 KAT-00 KAT-00 1.2 2. 2.. 7..7 2...7 2.. 7 1 2 2 Branch Y : KAU ød P Q KAU-00... 1.. 2. KAU0-00. 1..7 1.2.2 KAU0-00. 7 20..7 1. 1. KAU0-00 KAU-00 KAU-00 1.2 2. 1 2.. 0 1.2 1.7 1.1 1.1.7 2...7 2.. 7 1 Plug-in reducer: KAR Fitting size ød L A ød KAR-0.. 1.. 2. KAR0-0.. 1.. KAR0-0. 1 1.. 2.0 KAR0-... KAR0-0 7 2. KAR0-.. 1.1 1.1.0 KAR0-2 20.7 KAR0-1.0 1.2 20 1.0 1.0 KAR0-2. KAR-. 20 2. 2. 7-1