APPLICATION OF NIR TECHNOLOGY IN THE ANIMAL FOOD INDUSTRY

Similar documents
Application of Near Infrared Spectroscopy to Predict Crude Protein in Shrimp Feed

NIRS IN ANIMAL SCIENCES

NIRS WHITE PAPER. History and utility. Overview. NIRS Forage and Feed Testing Consortium. for forage and feed testing

Application of Raman Spectroscopy for Detection of Aflatoxins and Fumonisins in Ground Maize Samples

Near Infrared reflectance spectroscopy (NIRS) Dr A T Adesogan Department of Animal Sciences University of Florida

Near infrared reflectance spectroscopy of pasticceria foodstuff as protein content predicting method

APPLICATION OF NEAR INFRARED REFLECTANCE SPECTROSCOPY (NIRS) FOR MACRONUTRIENTS ANALYSIS IN ALFALFA. (Medicago sativa L.) A. Morón and D. Cozzolino.

Online NIR-Spectroscopy for the Live Monitoring of Hydrocarbon Index (HI) in Contaminated Soil Material

Evaluation of commercially available near-infrared reflectance spectroscopy prediction models for nutrient prediction of DDGS

Influence of different pre-processing methods in predicting sugarcane quality from near-infrared (NIR) spectral data

NIRS Programs That Give Accurate Data for Selections, Science and Marketing

Plum-tasting using near infra-red (NIR) technology**

ABASTRACT. Determination of nitrate content and ascorbic acid in intact pineapple by Vis-NIR spectroscopy Student. Thesis

Analysis of Cocoa Butter Using the SpectraStar 2400 NIR Spectrometer

NIRS Getting started. US Dairy Forage Research Center 2004 Consortium Annual Meeting

The use of near infrared spectroscopy (NIRS) to predict the chemical composition of feed samples used in ostrich total mixed rations

THE APPLICATION OF SIMPLE STATISTICS IN GRAINS RESEARCH

Putting Near-Infrared Spectroscopy (NIR) in the spotlight. 13. May 2006

Corresponding Author: Jason Wight,

PAT: THE EXTRACTION OF MAXIMUM INFORMATION FROM MESSY SPECTRAL DATA. Zeng-Ping Chen and Julian Morris

Note 133. Measurement of Chemical Lean in Beef, Pork and Lamb

Elimination of variability sources in NIR spectra for the determination of fat content in olive fruits

ADAPTIVE LINEAR NEURON IN VISIBLE AND NEAR INFRARED SPECTROSCOPIC ANALYSIS: PREDICTIVE MODEL AND VARIABLE SELECTION

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Multivariate calibration

College of Life Science and Pharmacy, Nanjing University of Technology, Nanjing, China

Multivariate data-modelling to separate light scattering from light absorbance: The Optimized Extended Multiplicative Signal Correction OEMSC

Quantifying Surface Lipid Content of Milled Rice via Visible/Near-Infrared Spectroscopy 1

Determination of Green Soybean (Edamame) Quality Using Near-Infrared Spectroscopy (Part,)*

Fast Analysis of Superoxide Dismutase (SOD) Activity in Barley Leaves Using Visible and Near Infrared Spectroscopy

Determination of Selected Parameters of Quality of the Dairy Products by NIR Spectroscopy

Detection and Quantification of Adulteration in Honey through Near Infrared Spectroscopy

Feedstuff NIR analysis in. farm to growth herd. ICAR 2011 Bourg en Bresse, June, 23 rd Rev A3.1 Page 1

BASICS OF CHEMOMETRICS

Explaining Correlations by Plotting Orthogonal Contrasts

Rapid Compositional Analysis of Feedstocks Using Near-Infrared Spectroscopy and Chemometrics

DETERMINATION OF CHEMICAL COMPOSITION OF MEDICAGO SATIVA PLANT BY DESTRUCTIVE AND NON-DESTRUCTIVE METHOD

Determination of Green Soybean (Edamame) Quality using Near-Infrared Spectroscopy (Part + )*

MULTIVARIATE STATISTICAL ANALYSIS OF SPECTROSCOPIC DATA. Haisheng Lin, Ognjen Marjanovic, Barry Lennox

Evaluating Labsphere s new UV-2000

Chemometrics The secrets behind multivariate methods in a nutshell!

NIRTurn-key on-line analysis systems

Particle size optimisation in development of near infrared microscopy methodology to build spectral libraries of animal feeds

GLOBAL SYMPOSIUM ON SOIL ORGANIC CARBON, Rome, Italy, March 2017

Advancing from unsupervised, single variable-based to supervised, multivariate-based methods: A challenge for qualitative analysis

Effect of Sample Preparation on Prediction of Fermentation Quality of Maize Silages by Near Infrared Reflectance Spectroscopy*

NIR Spectroscopy Identification of Persimmon Varieties Based on PCA-SVM

Prediction of beef chemical composition by NIR Hyperspectral imaging

2.01 INFRARED ANALYZER

On-line visible and near infrared (vis-nir) measurement of key soil fertility parameters in vegetable crop fields

FTIR characterization of Mexican honey and its adulteration with sugar syrups by using chemometric methods

PRECISION AGRICULTURE APPLICATIONS OF AN ON-THE-GO SOIL REFLECTANCE SENSOR ABSTRACT

Development of Near Infrared Spectroscopy for Rapid Quality Assessment of Red Ginseng

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

Robert P. Cogdill, Carl A. Anderson, and James K. Drennen, III

Using radial basis elements for classification of food products by spectrophotometric data

BIOLIGHT STUDIO IN ROUTINE UV/VIS SPECTROSCOPY

Biological and Agricultural Engineering Department UC Davis One Shields Ave. Davis, CA (530)

Application of Raman Spectroscopy for Noninvasive Detection of Target Compounds. Kyung-Min Lee

Spectroscopy in Transmission

Evaluation of potential nirs to predict pastures nutritive value

AUSSCAN NIR GRAIN STANDARDS DEVELOPMENT AND USER CALIBRATION UPGRADE 4B-119

Prof. Dr. Biljana Škrbić, Jelena Živančev

Research Article Near-Infrared Spectroscopy for Anticounterfeiting Innovative Fibers

Calibration optimization and efficiency in near infrared spectroscopy

Application of Time-of-flight Near-infrared Spectroscopy to Detect Sugar and Acid Content in Satsuma Mandarin

Whole Tablet Measurements Using the Frontier Tablet Autosampler System

Comparison of methods for the determination the fat content of meat

ANALYTICAL SCIENCES DECEMBER 2012, VOL The Japan Society for Analytical Chemistry

DIELECTRIC PROPERTIES OF CEREALS AT MICROWAVE FREQUENCY AND THEIR BIO CHEMICAL ESTIMATION

Compact Knowledge: Absorbance Spectrophotometry. Flexible. Reliable. Personal.

Inferential Analysis with NIR and Chemometrics

INFRARED SPECTROSCOPY

Control and traceability of ISPM 15 heat treatment

Validation of a leaf reflectance and transmittance model for three agricultural crop species

DATA COLLECTION AND ANALYSIS METHODS FOR DATA FROM FIELD EXPERIMENTS

Determination of meat quality by near-infrared spectroscopy

Integrating Sensor Based Process Monitoring and Advanced Process Control

Laboratory Exercise. Quantum Mechanics

Reprinted from February Hydrocarbon

Independence and Dependence in Calibration: A Discussion FDA and EMA Guidelines

Milk Analysis with the TIDAS P Milk Inspector

PREDICTION OF SOIL ORGANIC CARBON CONTENT BY SPECTROSCOPY AT EUROPEAN SCALE USING A LOCAL PARTIAL LEAST SQUARE REGRESSION APPROACH

Use of fourier transform infrared (FTIR) spectroscopy to predict VFA and ammonia from in vitro rumen fermentation

x Contents 3 The Stationary Phase in Thin-Layer Chromatography Activating and Deactivating Stationary Phases Snyder s Adsorption M

Comparison between feed microscopy and chemical methods for determining of crude protein and crude fiber content of commercial mixed feeds

Application of NIR Reflectance Spectroscopy on Rapid Determination of Moisture Content of Wood Pellets

Determination of Chemical Constituents in Processed Green Tea by Near Infrared Analysis

MULTIVARIATE PATTERN RECOGNITION FOR CHEMOMETRICS. Richard Brereton

Imaging Spectrometry on Mangrove Species Identification and Mapping in Malaysia

NIR applications for emerging vegetal contaminants

Whole Tablet Measurements Using the Spectrum One NTS Tablet Autosampler System

THE INTRODUCTION OF PROCESS ANALYTICAL TECHNOLOGY, USING NEAR INFRARED ANALYSIS, TO A PHARMACEUTICAL BLENDING PROCESS

Use of near-infrared spectroscopy for determining the characterization metal ion in aqueous solution

Application of near-infrared (NIR) spectroscopy to sensor based sorting of an epithermal Au-Ag ore

Application of color detection by near infrared spectroscopy in color detection of printing

Measurement uncertainty: Top down or Bottom up?

Nondestructive Determination of Tomato Fruit Quality Parameters Using Raman Spectroscopy

Prediction of Fermentation Parameters in Grass and Corn Silage by Near Infrared Spectroscopy

CHEMISTRY. CHEM 0100 PREPARATION FOR GENERAL CHEMISTRY 3 cr. CHEM 0110 GENERAL CHEMISTRY 1 4 cr. CHEM 0120 GENERAL CHEMISTRY 2 4 cr.

Transcription:

Biotechnology in Animal Husbandry 27 (4), p 1811-1817, 2011 ISSN 1450-9156 Publisher: Institute for Animal Husbandry, Belgrade-Zemun UDC 636.085 DOI: 10.2298/BAH1104811M APPLICATION OF NIR TECHNOLOGY IN THE ANIMAL FOOD INDUSTRY M. Maslovarić 1, R. Jovanović 1, S. Janković 1, J. Lević 2, N. Tolimir 1 1 Institute of Science Application in Agriculture, 11 000 Belgrade, Republic of Serbia 2 Institute of Food Technologies FINS, 21000 Novi Sad, Republic of Serbia Corresponding author: mmaslovaric@ipn.bg.ac.rs Original scientific paper Abstract: The importance of NIR technology in the animal food industry is presented in this study. As the example of the calibration procedure of NIR devices a calibration model for 14 samples of soybean cake was designed. Samples were previously analyzed in the standard laboratory testing of the moisture content, content of crude proteins, crude fats and crude fibre. In this calibration procedure high determination coefficients - R 2 were established for these parameters of the nutritional value of food (0.9783 for moisture, 0.9904 for crude proteins, 0.9872 for crude fats and 0.9351 for crude fibre). The comparison of values obtained by using standard laboratory methods with values obtained by NIR technology/method indicates that by using NIR devices it is possible to obtain highly reliable results, and therefore it can be used successfully in facilities for production of animal food in the control of the quality and projection of mixtures. Key words: NIR, animal food Introduction Adequate nutrition of animals includes knowledge of the characteristics of used feeds (Jovanovic et al., 2009). Also, intensive rearing of farm animals and stringent requirements in regard to the quality and quantity of animal products, require constant monitoring of the chemical composition of food for animals. On the other hand, strong competition in the field of production of animal food, imposes higher efficiency of the production process. Results obtained in the standard chemical analysis methods of major quality parameters of raw materials and finished mixtures are often received too late to stop the production process on time or correct it (Vries et al., 2010). Therefore, it is necessary to use fast analytical methods which enable fast response in cases when certain deviations are observed from the projected composition or quality of the product. In this way it is possible to achieve significant savings in the production process and ensure product of stable quality. NIR method of analysis is exceptionally fast (usual duration of

1812 M. Maslovarić et al. analysis is 10 seconds), non-destructive and does not require preparation of the sample for analysis. Main principle of NIR method of analysis. NIR(S) method (Near Infrared Reflectance Spectroscopy) is based on screening of sample by using near infrared reflectance/light, resulting in the spectrum of this individual sample. Spectrum can represent dependence of the reflected or transmitted radiation from the wave length. Results of the indirect NIR method, i.e. spectrum data, subsequently have to be transformed into required results concentration of the relevant constituent or functional property of the tested material, which is obtained by developing/designing of the calibration model. Calibration of NIR devices is done by using samples of known composition and properties determined by standard (reference) analysis methods. Calibration procedure includes application of certain mathematical and statistical techniques (chemometrics) for the purpose of obtaining of empirical equation which connects spectrum data with data obtained by chemical analysis (Stuth et al., 2003). The costs associated with chemical analysis of large number of samples (minimum 50, whereas approx. 150 chemical analyses of different samples is required for open calibration sample population) are typical for single chemometric method. Calibration of NIR devices requires certain amount of time, but it is facilitated by the possibility of sophisticated software packages which provide for the user application of chemometric calibration techniques (MLR Multiple Linear Regression, PLS Method of Partial Least Squares Regression, PCR Principal Component Regression, ANN Artificial Neural Network, etc). However, there are multiple benefits/advantages provided by the NIR method which are beyond the time and money invested in its implementation. Development of calibration model represent key step in successful implementation of NIR method and it comprises following phases: - Selection of calibration set of samples; robustness and accuracy of the calibration model greatly depend on the variability of the calibration population in sense of presence of samples of different varieties, samples of various maturity stages, samples originating from different cultivating regions and different production years (Tsuchikawa, 2007); - Collection of spectrum and reference data; - Execution of the regression (calibration) model and, Validation of the model; objective of the calibration model validation is to assess its predicting abilities in a routine application (Petersen, 2007; Boysworth and Booksh, 2008). We distinguish two types of validation procedure of NIRS calibration model; cross-validation and external validation, i.e. validation using an independent set of samples. Both procedures result in prediction error, i.e. error which can be expected in a routine application of model used to determine the quality, i.e. efficiency of the developed model (Esbensen, 2006), and which is based on the concept of

Application of NIR technology in the... 1813 differences between NIR results and results of reference laboratory analyses (Isaksson and Segtnan, 2007; Shenk et al., 2008). Materials and Methods Samples of soybean cake were analyzed using standard chemical methods (reference methods) and NIR method, in order to compare results of these two methods. Analyses were done in FSH Komponenta from Ćuprija. The analysis of the moisture content, content of crude fats and proteins was done on 14 samples, and analysis of crude fibre content on 9 samples of mentioned feed. All analyses were done according to the Rulebook on methods of physical, chemical and microbiological analysis of animal food from year 1987. Analysis of the moisture content was done on the laboratory moisture - meter OHAUS type MB45 for fast determination of moisture content. Chemical analysis of crude proteins was done according to method by Kjeldahl; for determination of the crude fats content the procedure of dry extraction according to Soxhlet method was applied, using VELP Scientifica digester and fat extraction apparatus. In chemical analysis of crude fibre the Weender method was used. Chemical analysis was done in two repetitions and average value of obtained results was considered in the study. For NIR analysis of samples NIR device was used - PERTEN Diode Array 7200, with rotating dish for measuring of samples, of diameter of 75 mm. This type of NIR device does not require previous grinding of samples, which is also an advantage. The wave length range from 950 to 1650 nm was used for measuring. The following mathematical transformations were carried out, on the spectrum of the soybean cake sample, in order to remove all irrelevant information from the spectrum, and to be able to interpret the results easier: Savitzky-Golay to obtain first spectrum excerpt and MSC Multiplicative scatter correction, and for the purpose of development of calibration model, PLS1 Partial Least Squares Regression. For transformation of the main spectrum of the soybean cake samples and execution/development of calibration model software package CAMO Unscrambler 10.1 was used. Results and Discussion In assessment of the efficiency of the obtained calibration model the following statistical tests were used: RMSEP Root Mean Square Error of Prediction and R 2 Determination coefficient R 2 (Table 1). Root Mean Square Error of Prediction RMSEP represent measure of the variability of differences between values obtained by NIR analysis (predicted values) and reference laboratory methods. When the value of RMSEP is closer to the zero, the calibration model is more reliable. Determination coefficient R 2, represents the square of the correlation coefficient r, and describes the variation and range of the calibration

1814 M. Maslovarić et al. set. Value of R 2 = 1, means that 100% of variations are described with the calibration (Pojić, 2010). Based on presented results it can be concluded that very good determination coefficients (R 2 ) in all cases are obtained. In comparison of concentration values of tested parameters obtained by standard laboratory method and those obtained by NIR method (Table 2), it is observed that results of the NIR method of analysis show no significant deviations from results obtained by standard laboratory methods, and errors which occurred did not exceed deviation regulated in the Rulebook on quality and other requirements for animal food ( Official Journal of RS, no. 4/2010). The highest determination coefficient (R 2 ) was achieved in crude proteins, which was expected since N-H chemical bond present in proteins shows high level of absorption of infrared radiation (Oatway et al, 2006). Very good determination coefficient (R 2 ) was also achieved in crude fats, although the concentration range of this constituent was considerably wide. Slightly lower determination coefficients (R 2 ) were obtained fro moisture and crude fibre. On the other hand, value of the Root Mean Square Error of Prediction - RMSEP was the lowest in crude fibre (lower than in crude proteins) which is explained by very narrow range of content of this parameter. Table 1. Concentration of crude proteins and crude fats in the calibration set (%), range of their values and results of the statistical cross validation Average of values, % SD Range R 2 RMSEP Moisture 7.31 1.52 4.06 9.65 0.9783 0.2442 Crude proteins 38.12 0.53 37.29-39.15 0.9905 0.0517 Crude fats 7.95 1.21 6.49-11.31 0.9884 0.0972 Crude fibres 6.02 0.32 5.72 6.91 0.9351 0.04331 SD Standard deviation, R 2 Determination coefficient, RMSEP Root Mean Square Error of Prediction. Table 2. Comparative review of the results of standard laboratory and NIR methods of analysis Sample Moisture Crude proteins Crude fats Crude fibres St.l.m, % NIR, % St.l.m, % NIR, % St.l.m, % NIR, % St.l.m, % NIR, % 1 4.060 4.446 37.780 38.669 8.880 8.761 5.720 5.742 2 7.540 7.752 38.140 38.202 7.000 7.131 6.080 6.001 3 7.000 6.849 37.720 37.674 8.880 8.985 5.900 5.927 4 8.080 8.373 37.810 37.816 7.180 7.082 5.880 5.882 5 8.160 8.047 37.400 37.391 7.290 7.406 5.920 5.952 6 9.130 8.921 37.330 37.349 6.490 6.533 5.680 5.705 7 7.130 7.143 37.800 37.798 8.090 8.061 6.020 6.002 8 8.160 8.266 37.770 37.791 7.950 7.858 6.100 5.952 St.l.m Value obtained by standard laboratory method NIR Value obtained by NIR method of analysis

Application of NIR technology in the... 1815 During the process of development of calibration model and its validation, certain number of samples had to be excluded in order to obtain the most reliable model possible. Therefore, the number of samples presented in Table 2 is lower than initial number of samples of soybean cake (9 samples for crude fibre and 14 samples for other parameters). This is also reason why, in case of moisture, crude proteins and crude fibre, a model was obtained which gives more reliable results, but with narrower range of contents of determined nutritional parameters. In case of crude fats, however, a calibration model was obtained which gives very reliable results for wide range of concentrations of this constituent. Based on obtained results it can be concluded that even with small number of samples which were tested by using standard laboratory methods of analysis, it is possible, using NIR method, to receive very reliable results, but adequate selection of samples for development of calibration model is of crucial importance. When the number of samples with various concentrations of relevant constituents is higher, a calibration model for wider range of concentrations can be developed, which would also give reliable results. There are also other ways of implementation of NIR technology, such as use of calibrations offered/provided by manufacturers of NIR devices. However, this way is associated with considerable costs. Also, calibration curves provided by manufacturers of NIR devices, although developed on large number of samples, often need to be adjusted due to high variations in the quality of raw materials. Conclusion Introduction of NIR technology is a good strategy of development of facilities for production of animal food, if the complexity of their production process is taken into consideration. NIRS method, as fast analytical method, enables timely receiving of required results, improvement in the quality control and increase in the efficiency of the animal food production, wit final outcome in increase of the profitability and competitiveness. Results obtained by applying NIR method in analysis of the soybean cake samples showed no significant differences compared to results obtained by standard laboratory methods, which proves that NIR method can be very reliable in determination of the composition of raw materials used in production of animal food, as well as of finished mixtures. Also, duration of NIR method of analysis was incomparably shorter than duration of standard laboratory methods.

1816 M. Maslovarić et al. Primena NIR tehnologije u industriji hrane za životinje M. Maslovarić, R. Jovanović, S. Janković, J. Lević, N. Tolimir Rezime Sve oštrija konkurencija u domenu proizvodnje hrane za životinjezahteva da proces proizvodnje bude što brži i efikasniji. NIRS metoda, kao izuzetno brza analitička metoda, predstavlja dobru soluciju koja poseduje veliki potencijal za unapređenje nadzora i kontrole proizvodnog procesa u fabrikama hrane za životinje. Uzorci sojine pogače analizirani su standardnim hemijskim metodama (referentne metode) i NIR metodom, u cilju poređenja rezultata ove dve metode. Analiziran je sadržaj vlage, sirovih proteina, sirove masti i sirove celuloze. U postupku kalibracije NIR uređaja za ove parametre kvaliteta sojine pogače, ostvareni su veoma dobri koeficijenti determinacije (R 2 ), što znači da su dobijeni pouzdani kalibracioni modeli. Rezultati dobijeni primenom NIR metode za analizu uzoraka sojine pogače (u postupku validacije modela), nisu se bitnije razlikovali od rezultata standardnih laboratorijskih metoda, što dokazuje da da NIR metoda može biti vrlo pouzdana u određivanju sastava, kako sirovina koje se koriste u proizvodnji hrane za životinje, tako i gotovih smeša. Prednosti uvođenja NIR tehnologije u fabrike hrane za životinje su: brza kontrola sadržaja relevantnih sastojaka u sirovinama i gotovim proizvodima, poboljšanje kvaliteta proizvoda, snižavanje troškova, mogućnost ugradnje NIR uređaja u proizvodni proces (at line analiza) - kontinualna kontrola procesa proizvodnje hrane za životinje. References BOYSWORTH M.K., BOOKSH K.S. (2008): Aspects of multivariate calibration applied to near - infrared spectroscopy. D.A. Burns & E.W. Ciurczak Handbook of Near Infrared Analysis, Boca Raton: CRC Press Taylor & Francis Group, 207-229. ESBENSEN K.H. (2006): Multivariate Data Analysis In Practice. Oslo: Camo Software AS GIVENS D.I., DEAVILLE E.R. (1999): The current and future role of near infrared reflectance spectroscopy in animal nutrition: a review. Aust. J. Agric. Res., 50, 1131-1145. DE VRIES P.F., JOVANOVIĆ R., POJIĆ M., MASLOVARIĆ. M., MILENKOVIĆ I. (2010): Značaj primene NIRS metode u fabrikama hrane za životinje u cilju poboljšanja kvaliteta i konkurentnosti. Zbornik radova 14. Međunarodnog simpozijuma tehnologije hrane za životinje - Tehnologija hrane za životinje, kvalitet i bezbednost.

Application of NIR technology in the... 1817 HRUSCHA W.R. (1987): Data analysis: Wavelength selection methods. In: WILLIAMS P.C., NORRIS K.H. (eds), Near Infrared Technology in the Agriculture and Food Industries. Am. Assoc. of Cereal Chem., St. Paul, MN, 35-55. ISAKSSON T., SEGTNAN V.H. (2007): Meat and fish products. Y. Ozaki, W.F. McCLURE and A.A. Christy, Near infrared spectroscopy in Food Science and Technology, Hoboken: John Wiley and Sons, 247-277. JOVANOVIĆ R., GRUBIĆ G., LEVIĆ J., JANKOVIĆ S. (2009): The effect of digestibility of maize hybrids on production performance of fattening young cattle. Biotechnology in Animal Husbandry, 25, 5-6, 677. OATWAY L.A., HELM J.H., JUSKIW P.E. (2006): Paper: Development of Near Infrared Spectroscopy to Screen for Feed Quality Characteristics in Whole Grain Barley, Field Crop Development Centre, Agriculture and Rural Development, Government of Alberta, USA. PETERSEN P.E. (2007): All you ever wanted to know about chemometrics but didn t like to ask. In Focus, 31, 22-23. POJIĆ M. (2010): Definisanje postupka za razvoj kalibracionog modela za blisku infracrvenu spektroskopiju. Doktorska disertacija, Tehnološki fakultet, Novi Sad. STUTH J., JAMA A., TOLLESON D. (2003): Direct and indirect means of predicting forage quality trough near infrared reflectance spectroscopy. Field Crops Res., 84, 45-46. SHENK J.S., (2004): The wonderful world of visible-near infrared spectra: theory and practice. A.M.C. Davies & Garrido-Varo, Proceedings of the 11 th International Conference on Near Infrared Spectroscopy, Chichester: NIR publications, 33-40 TSUCHIKAWA S. (2007): Determination of dry matter content and basic density of Norway spruce by near infrared reflectance and transmittance spectroscopy. Journal of Near Infrared Spectroscopy, 2, 127-135 VRIES P. F., JOVANOVIĆ R., POJIĆ M., MASLOVARIĆ. M., MILENKOVIĆ I. (2010): Značaj primene NIRS metode u fabrikama hrane za životinje u cilju poboljšanja kvaliteta i konkurentnosti, Zbornik radova 14. Međunarodnog simpozijuma tehnologije hrane za životinje - Tehnologija hrane za životinje, kvalitet i bezbednost, 304, 315. Received 30 June 2011; accepted for publication 15 August 2011