POLARIZATION STABILITY OF AMORPHOUS PIEZOELECTRIC POLYIMIDES

Similar documents
DIELECTRIC PROPERTIES OF PIEZOELECTRIC POLYIMIDES

POLARIZATION AND PIEZOELECTRIC PROPERTIES OF A NITRILE SUBSTITUTED POLYIMIDE

In Situ Poling and Imidization of Amorphous Piezoelectric Polyimides

EFFECTS OF MOLECULAR STRUCTURE ON MACROSCOPIC MECHANICAL PROPERTIES OF AN ADVANCED POLYMER (LARC -SI)

Non-Linear Finite Element Modeling of THUNDER Piezoelectric Actuators

Validation of High Displacement Piezoelectric Actuator Finite Element Models

Studies on dielectric properties of a conducting polymer nanocomposite system

I. INTRODUCTION II. SAMPLE PREPARATION JOURNAL OF APPLIED PHYSICS VOLUME 92, NUMBER 5 1 SEPTEMBER

HIGH-PERFORMANCE PERFLUORINATED POLYMER ELECTRET FILM FOR MICRO POWER GENERATION

RECENT PROGRESSES IN POLYMERIC SMART MATERIALS

Title. Author(s)H. H. PAN; C.K. CHIANG; R.H. YANG; Y.H. WU; C.S. CHA. Issue Date Doc URL. Type. Note. File Information CONTAINING SLAG

Structural evolutions in electroactive poly(vdf-co-trfe) copolymers for organic electronics

Chap. 7. Dielectric Materials and Insulation

Smart elastomers a touch of robotics

NOVEL PHENYLETHYNYL IMIDE SILANES AS COUPLING AGENTS FOR TITANIUM ALLOY

(12) Patent Application Publication (10) Pub. No.: US 2006/ A1. (19) United States 12-N

INCREASING INFORMATIVITY OF THE THERMALLY STIMULATED DEPOLARIZATION METHOD

Short-Term Dielectric Performance Assessment of BOPP Capacitor Films: A Baseline Study

Marine bio-inspired underwater contact adhesion

EAP - ElectroActive Polymers

PIEZOELECTRIC FOAMS BASED ON CYCLIC OLEFIN COPOLYMER

Piezoelectric Composites as Bender Actuators

DEVELOPMENT OF IMPROVED METHODS FOR CHARACTERISING THE CURE OF COMPOSITE MATERIALS

The electric field induced strain behavior of single. PZT piezoelectric ceramic fiber

Piezo materials. Actuators Sensors Generators Transducers. Piezoelectric materials may be used to produce e.g.: Piezo materials Ver1404

Finite Element Analysis of Piezoelectric Cantilever

Electrical Properties and Power Considerations of a Piezoelectric Actuator

ANISOTROPY IN THERMAL, ELECTRICAL AND MECHANICAL PROPERTIES OF SPIN-COATED POLYMER DIELECTRICS

Sensor Measurements For Diagnostic Equipment

Improving the dielectric and piezoelectric properties of screen-printed Low temperature PZT/polymer composite using cold isostatic pressing

Laser Interferometric Displacement Measurements of Multi-Layer Actuators and PZT Ceramics

Fourier transform infrared spectroscopy (FTIR) is a method used to obtain an infrared

Supporting Information

Thickness Optimization of a Piezoelectric Converter for Energy Harvesting

Electro-statically stricted polymers (ESSP)

Supporting Information

Introduction to electrets: Principles, equations, experimental techniques

QUANTITATIVE EVALUATION OF CURING SHRINKAGE IN POLYMERIC MATRIX COMPOSITES

Controlled actuation of Nafion-based Ionic Polymer-metal Composites (IPMCs) with Ethylene Glycol as Solvent

COURSE OUTLINE. Introduction Signals and Noise Filtering Sensors: Piezoelectric Force Sensors. Sensors, Signals and Noise 1

Analysis of Stress Relaxation Processes in Polyimides at High and Low Temperatures

Universal Standard Protocols for Temperature and Material Characterization Calibration with Pharmaceuticals by Thermal Analysis

UPGRADING OF PETROLEUM RESIDUE BY NITROGEN DOPING FOR CO 2 ADSORPTION

The Effects of Organotin Catalysts on Hydrolytic Condensation of

Three-dimensional flexible and conductive interconnected graphene networks grown by chemical vapour deposition

Pre-stressed Curved Actuators: Characterization and Modeling of their Piezoelectric Behavior

A COMPLETE STUDY OF ELECTROACTIVE POLYMERS FOR ENERGY SCAVENGING: MODELLING AND EXPERIMENTS

High Pressure DSC Differential Scanning Calorimeter

New Die Attach Adhesives Enable Low-Stress MEMS Packaging

APPLICATIONS OF THERMAL ANALYSIS IN POLYMER AND COMPOSITES CHARACTERIZATION. Wei Xie TA Instruments

Supporting Information for Polybenzimidazolium Salts: A New Class of. Anion-Conducting Polymer

Ion Concentration and Electromechanical Actuation Simulations of Ionic Polymer-Metal Composites

Piezoelectric Resonators ME 2082

A coupled field finite element model to predict actuation properties of piezoelectrically actuated bistable composites.

Solid State Science and Technology, Vol. 13, No 1 & 2 (2005) ISSN

DSC Methods to Quantify Physical Aging and Mobility in Amorphous Systems: Assessing Molecular Mobility

Direct measurement of giant electrocaloric effect in BaTiO 3 multilayer thick film structure beyond theoretical prediction

Thermal and mechanical properties of several phthalonitrile resin system

High-Performance Semiconducting Polythiophenes for Organic Thin Film. Transistors by Beng S. Ong,* Yiliang Wu, Ping Liu and Sandra Gardner

Supplementary Information

AC impedance and dielectric spectroscopic studies of Mg 2+ ion conducting PVA PEG blended polymer electrolytes

Tailoring actuation of ionic polymer-metal composites through cation combination

Ferroelectric Zinc Oxide Nanowire Embedded Flexible. Sensor for Motion and Temperature Sensing

Thermal Effect on E/M Impedance Spectroscopy of Piezoelectric Wafer Active Sensors

Development of Photosensitive Polyimides for LCD with High Aperture Ratio. May 24, 2004

Electronic Supplementary Information

The Kinetics of B-a and P-a Type Copolybenzoxazine via the Ring Opening Process

ANALYSIS OF DIELECTRIC, MODULUS, ELECTRO CHEMICAL STABILITY OF PVP ABSA POLYMER ELECTROLYTE SYSTEMS

Beads-On-String-Shaped Poly(azomethine) Applicable for Solution Processing of Bilayer. Devices using a Same Solvent

Characterisation of barium titanate-silver composites part II: Electrical properties

CHAPTER 6 DIELECTRIC AND CONDUCTIVITY STUDIES OF ZIRCONIUM TIN TITANATE (ZST)

Scalable Holey Graphene Synthesis and Dense Electrode Fabrication Toward High Performance Ultracapacitors

The strain response of silicone dielectric elastomer actuators

Non-Linear Finite Element Modeling of THUNDER Piezoelectric Actuators

ACOUSTIC EMISSION MEASUREMENTS ON PIEZOELECTRIC/ FERROELECTRIC MATERIALS

Measuring the Reaction Kinetics of Polyester/PCA-501(HAA) Powder Coatings With Dielectric Analysis (DEA)

Institute for Electron Microscopy and Nanoanalysis Graz Centre for Electron Microscopy

Dae Won Ji and Sang-Joo Kim

Magneto-Mechanical Modeling and Simulation of MEMS Sensors Based on Electroactive Polymers

SPECTROSCOPY MEASURES THE INTERACTION BETWEEN LIGHT AND MATTER

The effect of an inorganic filler on the properties of high-density polyethylene

Supplementary Information

Electrode effect on electrical conduction in thin film of polyvinyl pyrrolidone

Supplementary Information

Thin Film Bi-based Perovskites for High Energy Density Capacitor Applications

Comparative Study of Relaxation in Polymer Blends Film

Influence of Ceramic Particle Sizes on Electrical Properties of Lead Zirconate Titanate (PZT)/Nylon57 Composites

Active elastomer components based on dielectric elastomers

Advanced Electroactive Polymer Actuators and Sensors for Aerospace Robotic Applications (NNX13AN15A)

Chapter 4. Results and Discussion. 4.1 Monomer Syntheses

Supporting Information

Supporting Information

INTEGRATED REAL TIME STUDIES TO TRACK ALL PHYSICAL AND CHEMICAL CHANGES IN POLYIMIDE FILM PROCESSING FROM CASTING TO IMIDIZATION.

Protic Organic Ionic Plastic Crystals

Transduction Based on Changes in the Energy Stored in an Electrical Field

POLYAMIDE-6,9 WITH CARBAZOLE

CHEM*3440. Thermal Methods. Thermogravimetry. Instrumental Components. Chemical Instrumentation. Thermal Analysis. Topic 14

DSC AS PROBLEM-SOLVING TOOL: BETTER INTERPRETATION OF Tg USING CYCLIC DSC

Electronic Supplementary Information

Scheme 1: Reaction scheme for the synthesis of p(an-co-mma) copolymer

Transcription:

POLARIZATION STABILITY OF AMORPHOUS PIEZOELECTRIC POLYIMIDES C. PARK*, Z. OUNAIES**, J. SU*, J.G. SMITH JR. AND J.S. HARRISON Advanced Materials and Processing Branch, NASA Langley Research Center, Hampton VA, 23681-2199. *National Research Council **ICASE ABSTRACT Amorphous polyimides containing polar functional groups have been synthesized and investigated for potential use as high temperature piezoelectric sensors. The thermal stability of the piezoelectric effect of one polyimide was evaluated as a function of various curing and poling conditions under dynamic and static thermal stimuli. First, the polymer samples were thermally cycled under strain by systematically increasing the maximum temperature from 5 C to 2 C while the piezoelectric strain coefficient was being measured. Second, the samples were isothermally aged at an elevated temperature in air, and the isothermal decay of the remanent polarization was measured at room temperature as a function of time. Both conventional and corona poling methods were evaluated. This material exhibited good thermal stability of the piezoelectric properties up to 1 C. INTRODUCTION Aromatic polyimides have been used in a wide variety of aerospace applications because of their chemical and radiation resistance, with excellent thermal, mechanical, and dielectric properties. Recently, a series of novel piezoelectric polyimides containing pendant, polar groups have been synthesized and evaluated at NASA-LaRC for potential use in micro-electro-mechanical systems (MEMS) devices [1,2]. The initial investigations have shown that they exhibited a piezoelectric response at temperatures in excess of 15 C [3]. Experimental studies of the thermal stability of a piezoelectric amorphous polyimide, (β- CN)APB/ODPA, are presented here as a function of various curing and poling conditions under dynamic and static thermal stimuli. Both conventional and corona poling methods were employed for this study. Corona poling was used to maximize the degree of dipolar orientation and minimize localized arcing during in-situ imidization and poling. The results of both poling methods are discussed. EXPERIMENTAL Film preparation The polyimide evaluated was (β-cn)apb/odpa, which was prepared from 2,6-bis(3- aminophenoxy) benzonitrile ((β-cn)apb) and 4,4 oxidiphthalic anhydride (ODPA) via a polyamic acid solution in N,N-dimethylacetamide and subsequent thermal imidization. The synthesis was reported in detail elsewhere [3]. The polyamic acid solution was cast to form approximately 3µm thick films. The tack-free films were imidized under various cure cycles to produce samples having different degrees of imidization. The exact cure cycles are summarized in Table I. A silver layer, approximately 2nm thick, was evaporated on both sides of the films for conventional poling and only one side of the films for corona poling.

T before poling Table I. Processing parameters and properties of partially-cured, corona poled (β- CN)APB/ODPA: cure cycle, T g, degree of imidization (A178cm -1/ A15cm -1 ), and P r. Sample Cure cycle ( C) A178cm -1/ A15cm -1 P r 1 hour each, N 2 g ( C) (mc/m 2 ) P1 5, 1 97.18 N/A P15 5, 15 142.69 26 P2 5, 15, 2 166.82 9 P24 5, 15, 2, 24 218 1. 4 Poling The film specimens were poled using either a conventional or a positive corona poling procedure. For the conventional poling, each sample was polarized by the application of a DC electric field (8MV/m) at an elevated temperature (T g + 5 C) in a silicone oil bath. For corona poling, a DC field of 2 kv was applied to generate a positive corona using a single tungsten wire for four hours at 223 C and one hour at 212 C. The distance between the corona tip and the specimen was approximately 3mm. An argon gas was maintained during the poling process. For both poling processes, the dipoles were oriented with the applied field at a temperature above T g, with subsequent cooling to below T g in the presence of the applied field. The resulting remanent polarization (P r ) is directly proportional to the material s piezoelectric response, and estimated from the following equation [4], P r = ε ε E p (1) where ε is the permittivity of free space (8.854 pf/m), ε is the dielectric relaxation strength, and E p is the poling field. Characterization Degree of imidization. The glass transition temperatures (T g ) of the films were measured by differential scanning calorimetry using a Shimadzu DSC-5 at a heating rate of 2 C/min in air. The T g was taken as an inflection point of the shift of the baseline of the DSC thermogram. The degree of imidization was determined by a Nicolet FTIR spectrometer in an ATR mode using a Nicolet Continµm IR microscope. The absorption peak at 178cm -1 (sym. carbonyl stretch) was used to determine the degree of imidization and that at 15cm -1 (ring breathing modes of the aromatic moieties) was used as an internal standard [5]. The results are presented in Table I. Thermally stimulated current (TSC) measurement. After poling, P r was measured as a function of temperature. As the sample was heated through its T g at a heating rate of 1.5 C/min, the depolarization current was measured using a Keithly 6517 electrometer. The P r is equal to the charge per unit area, which is obtained from the data by integrating the current with respect to time and plotting it as a function of temperature. Piezoelectric Measurement. The piezoelectric strain coefficient (d 31 ) was measured using a Rheovibron DDV-II-C mechanical analyzer as a function of temperature for a range of frequencies. As the polymer is strained along the direction of applied stress, a charge Q is generated on the surface of the electrodes. A geometric factor is used to produce a geometry independent parameter, namely, surface charge density per unit applied stress. Thermal stability Measurements. Thermal stability of the piezoelectricity in the (β-cn) APB/ODPA system was carried out under both dynamic and isothermal conditions. First, the polymer sample was thermally cycled under strain by systematically increasing the maximum

temperature from 5 to 2 C at a heating rate of 2 C/min. The d 31 was measured as a function of temperature for four runs, where the maximum temperature for each run was 5, 1, 15, and 2 C. The effect of the dynamic temperature cycling on the d 31 was assessed as % retention of the piezoelectric response. Second, the as-poled samples were isothermally aged at 5, 1, 15, and 2 C in static air ovens. The aged samples at each temperature were tested periodically and the P r was measured and compared to that of the as-poled sample. The % retention of P r was plotted as a function of aging temperature and time. RESULTS Fully-cured, conventionally poled (β-cn)apb/odpa The remanent polarization of the fullycured, conventionally poled (β-cn)apb/odpa was approximately 2mC/m 2 when poled at 8MV/m for one hour above T g. Figure 1 summarizes the results of the long-term thermal stability of this polymer. The retained P r after isothermal aging is presented as a function of aging time at the various temperatures. Excellent thermal stability was observed up to 1 C, and no loss of the piezoelectric response was seen after aging at 5 C and 1 C up to 5 hrs. After aging at 15 C, 5% of the initial P r was retained after 1 hrs, and remained constant until 45 hrs, while at 2 C, 13% of the P r was retained after 1 hrs. 1 % Retention of Pr 8 6 4 2 1 5 C 5 C 1 C 1 5 C 2 C 2 C. 1 1 1 1 1 Aging time (hour) Figure 1. Thermal stability of P r of (β-cn)apb/odpa after aging at various temperatures. Thermal stability of the piezoelectric strain coefficient (d 31 ) under dynamic conditions was also studied and the results are shown in Figure 2. After cycling up to 5 C, no loss of the initial d 31 was observed on the 2nd run, as seen in the inset of Figure 2. The d 31 of this polymer rapidly increased with temperature above 9. A d 31 value of 5pC/N at the end of the 3rd run at 15 C and that of 1pC/N at 2 C at the end of the 4th run were obtained. These results are encouraging and portend use of these polyimides as sensors in high temperature aerospace applications.

d31 (pc/n) 1 8 6 4 2 d31 (pc/n). 9. 8. 7. 6. 5. 4 3 u p t o 5 C u p t o 1 C. 3 4 5 6 7 8 9 1 Temperature ( C) u p t o 5 C u p t o 1 C u p t o 15 C u p t o 2 C 5 1 15 2 Temperature ( C) Figure 2. Dynamic stability of d 31 of fully-cured, conventionally poled polyimide film (1 Hz). Partially-cured, corona poled (β-cn)apb/odpa. A positive corona poling was used for the partially-cured polymers in an attempt to maximize the degree of dipolar orientation and minimize localized arcing during in-situ imidization and poling. The aligned polar groups should be immobilized by additional imidization and subsequent cooling in the presence of an electric field. Table I summarizes the cure cycle, T g, and degree of imidization of the polyimides. Both the T g and the degree of imidization increased almost linearly with the final cure temperature. Thus, higher mobility of the dipoles should be expected for the polymers cured at a lower temperature. The remanent polarization of these specimens was measured, and listed in Table 1. The value of P r appeared higher when cured at lower temperature. Since the mobility of the molecules of the partially-cured polyimide should be much higher than that of the fully-cured one, the polar groups of the former are expected to orient parallel to the field direction more efficiently than the latter. Therefore, poling in a partially imidized state may produce a higher degree of dipole orientation than poling in a fully imidized state, thereby generating higher P r. The P15 partially-cured polyimide exhibited six times higher P r than the fully-cured one under the same corona poling condition, which was greater than expected from the preliminary dielectric measurement. Figure 3 shows an example of the P r of a partially-cured, corona poled (β-cn) APB/ODPA (P15). The partially-cured polymers tend to show broad double depolarizing current peaks during TSC measurement while the fully-cured ones depolarize with one sharp peak near T g. The double peaks imply incomplete imidization during poling since the peak represent the T g and the dipoles poled in a partially imidized state are thermally less stable than those poled in a fully imidized state. Since the poling temperature for the partially-cured polymers was selected 5 C above T g of the fully-cured one, the dipoles aligned in the early stage (unimidized state) may not have had enough time to relax their excessive free volume during the in-situ imidization and poling process. A gradual increase of the poling temperature may be desirable to shift the lower peak maximum to the higher temperature, providing more thermal stability to the polarized dipoles. Figures 4(a) and (b) show the normalized retention of the piezoelectric strain coefficient, d 31 of the dynamic stability tests for both fully-cured, conventionally poled and the partiallycured, corona poled (β-cn)apb/odpa (P15), respectively. In both cases, the films exhibit

.14 3 Current/area (ma/m 2 ).12.1.8.6.4.2 Current/area (ma/m 2 ) P r (mc/m 2 ) 25 2 15 1 5 P r (mc/m 2 ) 5 1 15 2 25 Temperature ( C) Figure 3. Thermally stimulated current measurement: current/area and P r versus temperature for partially-cured (β-cn) APB/ODPA (P15). very good thermal stability and virtually no loss of d 31 was observed prior to reaching 15 o C. After 15 C, both films exhibited noticeable loss of d 31, however, the fully-cured specimen still retained about 6% of the initial value while the partially-cured one retained less than 2%. The lower value of the partially-cured one may be an artifact due in part to incomplete imidization (Figure 3). Further investigations in this matter are underway. The thermal stability of the poled amorphous polyimide films did not show a significant change in the range of the measurement frequencies, from 1Hz to 1Hz for both poling processes. CONCLUSIONS Thermal stability of the amorphous piezoelectric polyimide was evaluated as a function of curing and poling conditions. The piezoelectricity of this polymer was stable under both dynamic and static thermal stimuli and statistically no loss was observed up to 1 C. The partially-cured, corona poled polymers exhibited improved remanent polarization. Since this amorphous piezoelectric polyimide can generate a piezoelectric response at elevated temperatures, its thermal stability should be beneficial for high temperature aerospace applications. ACKNOWLEDGEMENTS The authors acknowledge Dr. Terry L. St. Clair of NASA-LaRC for his technical insight. We also acknowledge Mr. Bill White of Wyle Laboratories for development of the characterization measurement software.

% Retention of piezoelectricty, d31 12 1 8 6 4 2 at 5 o C 5 1 15 2 Final cycle temperature ( C) (a) 1Hz 1Hz 1Hz % Retention of piezoelectricty, d31 12 1 8 6 4 2 at 5 o C 5 1 15 2 Final cycle temperature ( C) (b) 1Hz 1Hz 1Hz Figure 4. Percent retention of the piezoelectric strain coefficient, d 31 at 5 C after cycling up to 5, 1, 15, and 2 C, (a) fully-cured sample (conventional poling: 8MV/m, 22 C for 6min), (b) partial cured sample (corona poling) REFERENCES 1. J.O. Simpson, S.S. Welch, and T.L. St. Clair, in Materials for Smart Systems II, edited by E.P. George, et al. (Mater. Res. Soc. Proc. 459, Boston, MA, 1997) pp. 351 356. 2. J.O. Simpson, Z. Ounaies, and C. Fay, in Materials for Smart Systems II, edited by E.P. George, et al. (Mater. Res. Soc. Proc. 459, Boston, MA 1997) pp. 59 64. 3. Z. Ounaies, C. Park, J.S. Harrison, J.G. Smith, and J. Hinkley, in Smart Structures and Materials: Electroactive Polymer Actuators and Devices, edited by Y. Bar-Cohen (Proc. SPIE 3669, Newport Beach, CA 1999) pp. 171 178. 4. B. Hilczer and J. Malecki, Electrets; Studies in Electrical and Electronic Engineering 14, Elsevier, New York, 1986, p. 19. 5. C.A. Pryde, J. Polym. Sci.: Part A: Polym. Chem. 27, p. 711 (1989).