Single Method On-line Analyzers

Similar documents
ADI 201Y Single Method On-line Analyzers

Single Method On-line Analyzers. ADI 2016 Titrolyzer ADI 2018 Ion-Analyzer ADI 2019 Process Colorimeter

ADI 2040 Process Analyzer

2035 Process Analyzer. Customized online monitoring of industrial processes and wastewater

ADI2045VA Process Analyzer

ADI 2045TI Process Analyzer. Multi-purpose wet chemical analysis

ph Calibration Buffers

On-line Analyzers. Process Liquids Process Water

Speed and flexibility

Automatic Potentiometric Titrator [AT-710S]

ISEmax CAM40/CAS40. Technical Information

MULTI_T. Digital Titrator for Multi-tasking Titrations

Reagents for Chemical Test Kits

SMARTCHEM 300 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

Process Instrumentation analyzers

SMARTCHEM 200 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

Determination of Zinc, Cadmium, Lead and Copper in Effluent Sample

SMARTCHEM 140 DIRECT READ DISCRETE ANALYZER FOR SIMPLE AND AUTOMATED CHEMISTRIES

Magnetic Flowmeter Material Selection Guide

Application Bulletin

Fertilizer Methods List for Automated Ion Analyzers. Flow Injection Analysis

Concise laboratory catalogue

Nanotechnology Sensors

Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

SMARTCHEM 140. DIRECt READ DISCREtE ANAlyZER FOR SIMPlE AND AUtOMAtED CHEMIStRIES

F- Cl- Br- I- CN- S2- NO3-

Extra Questions. Chemical Formula IUPAC Name Ionic, Molecular, or Acid. ethanol. sulfurous acid. titanium (IV) oxide. gallium sulfate.

PAA-ANALYZERS PRINCIPLE OF OPERATION

Photometer AL250. Scroll Memory (SM) N.I.S.T Traceability. Highlights

Peek Chemical Resistance

Air Monitoring. Semi-continuous determination of ambient air quality

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

CENTRAL LABORATORY. Sl. No. Type of sampling Charges in Rs. 1. GRAB SAMPLING:

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting.

Application Bulletin

Automatic titrators, TitroMatic

Automating Wet Chemical Analysis

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations

Titrasure standards and volumetric solutions...for guaranteed results

La nueva línea de tituladores y buretas

INSTRUCTIONS ON EVERY AP EXAM:

Mercury Stack Monitor SM-4

Water Analysis VISOCOLOR VISOCOLOR. Water analysis made easy. VISOCOLOR tests for water analysis

The first address for Titration. TITRONIC 300 and TitroLine 5000

Kjeltec 2300 Analyzer Unit

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

on-line analyzer systems for safety and control of chlorine production plants by Chris Du Bois by Thibaut Bettini Buenos Aires Argentina Nov.

Definition 1 An element or compound is oxidized when it gains oxygen atoms

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

Sl. NO DESCRIPTION MAKE UNIT RATE

University Wet Chemistry Analyzer Packages

The design and operational theory of ph electrodes is a very complex subject, explored only briefly here. What is important to understand is that thes

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Glossary of Common Laboratory Terms

8 Materials, Corrosion Resistance Tables

CHEMICAL RESISTANCE DATA FOR POLYETHYLENES

METHOD STATEMENT. Determinand: Ammonia, Chloride, Nitrate, Nitrite, Orthophosphate, Sulphate & TON. Matrix: Leachates, effluents and wastewaters

Na+ K+ Ag+ Ca2+ NH + 4. F- Cl- Br- I- CN- S2- NO3-

National standard of People s Republic of China

How to become a formulation hero

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Inventory Locations. RICCA Over 40 years of successfully serving you, our customer

METHOD 9012B TOTAL AND AMENABLE CYANIDE (AUTOMATED COLORIMETRIC, WITH OFF-LINE DISTILLATION)

3.2.5 Group VII. Trends in Physical Processes. 70 minutes. 70 marks. Page 1 of 7

Ion Selective Electrodes

UDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS

water proof water proof Tap water, pure water application Precious, trace amount sample 3-in-1 Plastic Electrode D

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

Application Your benefits

Karl-Fischer Titration the method for determining water

All Questions are to be attempted 1- Redox Titration (35 Marks)

PROCESS REFRACTOMETER FOR CONCENTRATION MEASUREMENT OF CHEMICALLY AGGRESSIVE LIQUIDS PROCESS REFRACTOMETER PR-23-W/PR-23-M SB:PR-23-W/M

DSA 5000 M. Density and Sound Velocity Meter. ::: Unique Density & Concentration Meters

Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox,

Media Compatibility Guide PVC Valves

Ion-selective Measurements

ICSE Board. Class X Chemistry. Board Paper Time: 1½ hrs Total Marks: 80

ISO-TECH SYSTEM, VARANASI Analysis by ph and ion selective electrodes

AP Chemistry Summer Assignment

ION CHROMATOGRAPHY SYSTEM S 150

Immediate Free Chlorine Correction for Fluctuating Flow & Changes in Water Quality. Sadiq Khan May 25th, 2016

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

Equivalent Yokogawa TM Sensors

IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000

University of Kentucky College of Agriculture Division of Regulatory Services

Chemical Resistance Guide for Flowchem EPN

WATER QUALITY ANALYZERS SENSOR TECHNOLOGY. Customer Registration System. Dimesional Outlines Unit: mm(in) ORP ION. Conductivity.

Appendix 1. Periodic Table and Atomic Structure. History of the idea of elements.

N5 Chemistry. Unit 3 Chemistry in Society Practice Questions. Sgoil Lionacleit

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

DR/4000 PROCEDURE. HARDNESS, Total

Transcription:

Single Method On-line Analyzers ADI 2016 Titrolyzer ADI 2018 Ion-Analyzer ADI 2019 Process Colorimeter

ADI 2016 / 2018 / 2019 Automatic and dependable On-line Ion Analysis The single method Process Analyzers of Metrohm Applikon B.V. can be applied in many different industries to analyze and control their wet chemical processes. The single method analyzers are available for: Titrations ADI 2016 Titrolyzer Ion Selective measurements ADI 2018 Ion-Analyzer Colorimetric analysis ADI 2019 Process Colorimeter Many proven applications in the analysis of wet chemical processes are available for (petro)chemical-, mining-, semiconductor-, pulp-, paper-, textile-, food- and many other industries for process as well as effluent streams. A flexible wet part containing modules like valves, sampling devices, pumps, sensors etc. and the flexibility in setting up program runs, measuring ranges and result calculation allow a configuration for almost every application. Easy operation by use of programmable macro s with dialog functions. Combination of corrosion resistant plastic and epoxy coated steel, or fully stainless steel cabinets. Electronics fully shielded from the so-called wetpart. Ingress protection according to IP65 and NEMA 4X. Smart design of hard- and software and application of special analytical methods allows automatic calibration and validation of the results. Batch-wise operation allows the analysis frequency to be defined, which leads to a significant reduction in reagent usage. A flexible design makes it possible to automate your laboratory method ensuring that the analyzer generates the same result as your laboratory. Automation The analyzers can run three different programs which can conveniently be adapted to the specific needs of the application. A Clean program for periodic cleaning of sampling device, analysis vessel or cuvette and sample lines. A Reference or calibration program for periodically performing a reference analysis on a standard. A titrant or electrode offset can automatically be adjusted. An Analysis program for on-line sample analysis. The programs are executed in a user definable sequence with a user selectable time interval. Conditional actions based on the result outcome are available to trigger alarms, increase/decrease analysis frequency, and perform Cleaning and Reference programs.

ADI 2016 Titrolyzer Analysis techniques The ADI 2016 Titrolyzer performs potentiometric titrations by means of a high precision burette system and high-performance electrodes: Acid/Base titrations Redox titrations Precipitation titrations Karl Fischer titrations A self finding inflection point technique can be applied for most applications. This can be performed either with fixed time interval additions or with drift controlled additions, depending on the application. For some applications also a (temperature compensated) end-point technique is available. Karl Fischer titration is a special version of that. Titration Titration is one of the most applied and proven analysis techniques. This can be explained by the fact that it uses very straightforward instrumentation and yet delivers most accurate analysis results. This is also reflected in the following features brought by the ADI 2016 Titrolyzer: No need for calibration since titration is an absolute method. Also the applied electrode does not need calibration because the inflection point is derived from the measured potential differentials, rather than the absolute potentials. Great selectivity through the use of dedicated titrants and electrodes. Several parameters can be obtained by multipoint titration, e.g. P and M number, or Alkalinity and Carbonate. 12 11 10 9 ph 8 7 6 5 4 3 2 1 0 EP2 EP1 1 2 3 4 5 6 7 8 9 V (ml)

ADI 2016 / 2018 / 2019 ADI 2018 Ion-Analyzer Analysis technique The ADI 2018 Ion-Analyzer performs a dynamic standard addition method by means of a high precision burette and highperformance Ion Selective Electrodes (ISE). These methods adapt the standard addition volume to the actual sample concentration by means of a dynamic differential approach. Moreover it takes into account ISE slope values over several ranges. This means that ISE s can be used to their ultimate low (or high) measuring range which is mostly non-linear. Finally an accompanying temperature measurement eliminates possible temperature effects on the analysis results. Dynamic Standard Addition The above described method brings important benefits making ion selective measurements a robust on-line analysis approach with the following features: Intrinsic result validation. Elimination of sample matrix effects. Automatic ISE calibration. Wide measuring range of approx. 2.5 decades. Easy adaptable measuring range by choosing the standard concentration. Significant reagent usage reduction; only buffer and standard solution (typical 0.5 to 1 ml per analysis). Automatic temperature compensation. E (mv) slope 1 slope 2 slope 3 slope 4 0.1 0.32 1 3.2 10 log concentration

ADI 2019 Process-Colorimeter Analysis technique The ADI 2019 Process-Colorimeter performs photometric absorption measurements in the visible light range. A by Metrohm Applikon developed high performance compact photometer module is utilized. It comprises a thermostated cuvette with 3 cm light path and LED technology. The color development stabilization is automatically detected by making use of differential absorbance measurements. The ADI2019 will have no problem performing your color laboratory method; in most cases it can be directly implemented in a simple way. Differential colorimetry Differential measuring method as applied by Metrohm Applikon makes colorimetry a robust, accurate on-line analysis tool, featuring: A1 A A0 Reagent addition Time Color development Insensitive for cuvette fouling, background sample color or ageing of light source. High accuracy and repeatability. High sensitivity, typical in the low µg/l. Processes linear as well as curved calibration lines, in order to offer wide measuring ranges. Significant reagent usage reduction; only buffer and standard solution (typical 0.5 to 1 ml per analysis). Insensitive to sample temperature variations

ADI 2016 / 2018 / 2019 Preconditioning and Stream selector Not only the chemical analysis, but also the sample preparation or preconditioning is of the utmost importance for the success of a process analyzer system. Furthermore, the analyzer location is an important part of the analysis. The sample needs to be as representative as possible, which means that the sampling point needs to be as close to the analyzer as possible. Metrohm Applikon can engineer and supply virtually any unit operation for sample preconditioning: pressure reduction cooling heating, heat tracing (ultra) filtration precipitation dilution to avoid crystallisation degassing homogenising flow metering phase separation With more than 35 years of experience in process analyzer systems Metrohm Applikon can provide a complete and exact solution for almost any application. Projects range from one Analyzer in combination with simple sample preparation to complete packages with shelters, piping, wiring and interfacing. On-site, only the necessary utilities and the sample stream need to be connected, saving a lot of time and energy in the start up phase of the instrument. Multi-stream Analyzer In some cases the Analyzer can be equipped with a sample sequencer. This unit makes it possible to monitor multiple sample streams with one Analyzer. Each individual sample stream is assigned to an analog output module (4-20mA) that transfers the analysis result of the chosen sample stream to a process computer.

Typical applications 2016 2018 2019 Industry Chemical Metal Metal Semi Food Pulp, paper, Power Water Component industry mining surface conductor textile Quality Acidity Alkalinity Aluminium Ammonia Boric Acid Bromide Bromine Cadmium Calcium Caustic Carbonate Chlorate Chloride Chlorine Chromium Citric Acid Cobalt COD Copper Cyanide Dithionite EDTA Fatty Acid Fluoride Formaldehyde Glucose Hydrazine Hydrochloric Acid Hydrofluoric Acid Hypochlorite Hypophosphite Iodide Iron Lactic Acid Leuco Indigo Magnesium Manganese Molybdenum Nickel Nitrate Nitric Acid Nitrite Nitrous Acid P & M number Permanganate Peroxide Persulphate Phenol Phosphate Phosphoric Acid Phtalic Acid Potassium Silica Silver Sodium Sulphide Sulphite Sulphonic Acid Sulphuric Acid Surfactant Thiocyanate Titanium Urea Water Zinc

Specifications / general information Applied Analysis methods ADI 2016 ADI 2018 ADI 2019 Titrations Dynamic Standard Addition with Ion Selective Electrodes Differential Absorbance Colorimetry Measurement Repeatability typical 1-2% Inaccuracy typical 1-2% (95% confidence level) Analysis time typical approx. 10 minutes Sampling and sample streams Sampling batch wise Sample frequency programmable Sample streams Titrolyzer: 1 stream + standard Ion Analyzer: 2 streams + blank Colorimeter: 1 stream + standard Sample volume 0.2-50 ml Sample temperature 5-90 C / 41-194 F Sample pressure 0-4 bar / 0-7,2 PSI (without preconditioner) Maintenance Weekly Monthly Yearly visual inspection visual inspection & reagent refill hardware inspection Connectivity Serial Communication Analog Outputs Digital Input Digital Output RS232, RS422 2 x 0(4) - 20 ma remote start, remote stop, remote emergency stop analyzer running system error result value low alarm result value high alarm no sample alarm out of reagent alarm 3 programmable relays General Power supply 100-120 / 200-240V / 200 VA / 50..60Hz Accessibility pass code protected Housing material Standard system: Electronics cabinet: Zinc plated steel, epoxy coated steel Wet part door: Polystyrene, epoxy coated Special system: Stainless Steel SS316 Ingress protection IP65 and NEMA 4X Ambient temperature 5-40 ºC Dimensions H x W x D 700 x 460 x 352 mm Weight 45 kg max About Metrohm Applikon Metrohm Applikon has been developing, manufacturing and supplying on-line analytical systems using electrochemical measurements for over 25 years. Thousands of Metrohm 2016 2018 2019 Alert Alert 2040 ExProof 2040 2040 ExProof 2045VA 2045VA Metrohm Applikon B.V. De Brauwweg 13, P.O. Box 149, 3100 AC Schiedam The Netherlands Phone: +31 10 298 35 55 Applikon Analyzers are in use every day controlling the world s most demanding processes and protecting some of the most sensitive environments. Metrohm Applikon systems are available using titration, colorimetric analysis, ion selective electrodes or more complex electrochemical analysis techniques such as voltammetry and ion chromatography. The modular system makes it possible to meet the needs for each customer or application. Metrohm Applikon has customers in environmental, water, power, electronics, petro/chemical, metal, galvanic, mining, pulp and paper, textile, food, beverage, pharmaceutical and biotechnology industries. Read more on www.metrohm-applikon.com Fax: +31 10 437 96 48 E-mail: analyzers@metrohm-applikon.com www.metrohm-applikon.com Single Method On-line Analyzers - V2XG121010 - Subject to modifications - Printed by Metrohm Applikon bv - The Netherlands November 2011