A Note on Bode Plot Asymptotes based on Transfer Function Coefficients

Similar documents
PAPER Sensitivity of Time Response to Characteristic Ratios

CHAPTER 7 : BODE PLOTS AND GAIN ADJUSTMENTS COMPENSATION

Robust Tuning of Power System Stabilizers Using Coefficient Diagram Method

The Complete Set of PID Controllers with Guaranteed Gain and Phase Margins

MULTILOOP PI CONTROLLER FOR ACHIEVING SIMULTANEOUS TIME AND FREQUENCY DOMAIN SPECIFICATIONS

Tuning Method of PI Controller with Desired Damping Coefficient for a First-order Lag Plus Deadtime System

Radar Dish. Armature controlled dc motor. Inside. θ r input. Outside. θ D output. θ m. Gearbox. Control Transmitter. Control. θ D.

Control Systems Engineering ( Chapter 8. Root Locus Techniques ) Prof. Kwang-Chun Ho Tel: Fax:

Root Locus. Signals and Systems: 3C1 Control Systems Handout 3 Dr. David Corrigan Electronic and Electrical Engineering

Chapter 6 - Solved Problems

a. Closed-loop system; b. equivalent transfer function Then the CLTF () T is s the poles of () T are s from a contribution of a

Robust Performance Example #1

Poles and Zeros and Transfer Functions

Analyzing the Stability Robustness of Interval Polynomials

Outline. Classical Control. Lecture 1

Step input, ramp input, parabolic input and impulse input signals. 2. What is the initial slope of a step response of a first order system?

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING

Stability Margin Based Design of Multivariable Controllers

Fixed-Order Robust H Controller Design with Regional Pole Assignment

Homework 7 - Solutions

Analysis of SISO Control Loops

Example on Root Locus Sketching and Control Design

Single-Time-Constant (STC) Circuits This lecture is given as a background that will be needed to determine the frequency response of the amplifiers.

Control of Electromechanical Systems

8.1.6 Quadratic pole response: resonance

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

Control Systems I. Lecture 7: Feedback and the Root Locus method. Readings: Jacopo Tani. Institute for Dynamic Systems and Control D-MAVT ETH Zürich

Systems Analysis and Control

Chemical Process Dynamics and Control. Aisha Osman Mohamed Ahmed Department of Chemical Engineering Faculty of Engineering, Red Sea University

(b) A unity feedback system is characterized by the transfer function. Design a suitable compensator to meet the following specifications:

Computation of Stabilizing PI and PID parameters for multivariable system with time delays

Control Systems I. Lecture 6: Poles and Zeros. Readings: Emilio Frazzoli. Institute for Dynamic Systems and Control D-MAVT ETH Zürich

Asymptotic Bode Plot & Lead-Lag Compensator

Bode Diagrams School of Mechanical Engineering ME375 Frequency Response - 29 Purdue University Example Ex:

Outline. Classical Control. Lecture 5

DESIGN USING TRANSFORMATION TECHNIQUE CLASSICAL METHOD

ELECTRONICS & COMMUNICATIONS DEP. 3rd YEAR, 2010/2011 CONTROL ENGINEERING SHEET 5 Lead-Lag Compensation Techniques

Observer Based Friction Cancellation in Mechanical Systems

APPLICATIONS FOR ROBOTICS

Control Systems I. Lecture 9: The Nyquist condition

Lecture 6 Classical Control Overview IV. Dr. Radhakant Padhi Asst. Professor Dept. of Aerospace Engineering Indian Institute of Science - Bangalore

Proportional plus Integral (PI) Controller

Control Systems. Root Locus & Pole Assignment. L. Lanari

Data Based Design of 3Term Controllers. Data Based Design of 3 Term Controllers p. 1/10

Dynamic circuits: Frequency domain analysis

Exercises for lectures 13 Design using frequency methods

PM diagram of the Transfer Function and its use in the Design of Controllers

Frequency domain analysis

6.1 Sketch the z-domain root locus and find the critical gain for the following systems K., the closed-loop characteristic equation is K + z 0.

Automatic Control 2. Loop shaping. Prof. Alberto Bemporad. University of Trento. Academic year

Available online at ScienceDirect. Procedia Engineering 100 (2015 )

Design and Tuning of Fractional-order PID Controllers for Time-delayed Processes

Simulation Study on Pressure Control using Nonlinear Input/Output Linearization Method and Classical PID Approach

Root Locus Methods. The root locus procedure

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Control Systems I. Lecture 7: Feedback and the Root Locus method. Readings: Guzzella 9.1-3, Emilio Frazzoli

1 (20 pts) Nyquist Exercise

Robust fixed-order H Controller Design for Spectral Models by Convex Optimization

Andrea Zanchettin Automatic Control AUTOMATIC CONTROL. Andrea M. Zanchettin, PhD Spring Semester, Linear systems (frequency domain)

Frequency Response Analysis

The requirements of a plant may be expressed in terms of (a) settling time (b) damping ratio (c) peak overshoot --- in time domain

Recent Development of Coefficient Diagram Method

A NEW APPROACH TO MIXED H 2 /H OPTIMAL PI/PID CONTROLLER DESIGN

ECE 345 / ME 380 Introduction to Control Systems Lecture Notes 8

Model-based PID tuning for high-order processes: when to approximate

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

ECE 486 Control Systems

School of Mechanical Engineering Purdue University. DC Motor Position Control The block diagram for position control of the servo table is given by:

PID CONTROLLER SYNTHESIS FREE OF ANALYTICAL MODELS

EECE 301 Signals & Systems Prof. Mark Fowler

Robust PID and Fractional PI Controllers Tuning for General Plant Model

ESE319 Introduction to Microelectronics. Feedback Basics

Frequency methods for the analysis of feedback systems. Lecture 6. Loop analysis of feedback systems. Nyquist approach to study stability

ECSE 4962 Control Systems Design. A Brief Tutorial on Control Design

Chapter 8: Converter Transfer Functions

Design and Implementation of Sliding Mode Controller using Coefficient Diagram Method for a nonlinear process

ROOT LOCUS. Consider the system. Root locus presents the poles of the closed-loop system when the gain K changes from 0 to. H(s) H ( s) = ( s)

Implementation Issues for the Virtual Spring

MAK 391 System Dynamics & Control. Presentation Topic. The Root Locus Method. Student Number: Group: I-B. Name & Surname: Göksel CANSEVEN

Inertia Identification and Auto-Tuning. of Induction Motor Using MRAS

Process Identification for an SOPDT Model Using Rectangular Pulse Input

EXPERIMENTAL IMPLEMENTATION OF CDM BASED TWO MODE CONTROLLER FOR AN INTERACTING 2*2 DISTILLATION PROCESS

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad ELECTRICAL AND ELECTRONICS ENGINEERING TUTORIAL QUESTION BANK

Control Systems I Lecture 10: System Specifications

Chapter 2. Classical Control System Design. Dutch Institute of Systems and Control

A FEEDBACK STRUCTURE WITH HIGHER ORDER DERIVATIVES IN REGULATOR. Ryszard Gessing

Iterative Controller Tuning Using Bode s Integrals

100 (s + 10) (s + 100) e 0.5s. s 100 (s + 10) (s + 100). G(s) =

Course roadmap. Step response for 2nd-order system. Step response for 2nd-order system

Chapter 9: Controller design

EE C128 / ME C134 Fall 2014 HW 8 - Solutions. HW 8 - Solutions

Engraving Machine Example

Fast Step-response Evaluation of Linear Continuous-time Systems With Time Delay in the Feedback Loop

R a) Compare open loop and closed loop control systems. b) Clearly bring out, from basics, Force-current and Force-Voltage analogies.

IMPROVED TECHNIQUE OF MULTI-STAGE COMPENSATION. K. M. Yanev A. Obok Opok

MAE 143B - Homework 9

Systems Analysis and Control

Robust Stability based PI Controller Design with Additive Uncertainty Weight for AGC (Automatic Generation Control) Application

Frequency Response DR. GYURCSEK ISTVÁN

H(s) = s. a 2. H eq (z) = z z. G(s) a 2. G(s) A B. s 2 s(s + a) 2 s(s a) G(s) 1 a 1 a. } = (z s 1)( z. e ) ) (z. (z 1)(z e at )(z e at )

Transcription:

ICCAS5 June -5, KINTEX, Gyeonggi-Do, Korea A Note on Bode Plot Asymptotes based on Transfer Function Coefficients Young Chol Kim, Kwan Ho Lee and Young Tae Woo School of Electrical & Computer Eng., Chungbuk National University, Cheongju 36-763, Korea (Tel: +8-43-6-475; Fax: +8-43-7-475; Email:yckim@cbu.ac.kr) Abstract: In this note, we present a different asymptotes from the standard approximate lines of the Bode magnitude plot. Wherein the pseudo break frequency is defined in terms of coefficients of denominator and numerator polynomials of the transfer function instead of its poles and zeros. Several comparative examples are given. This result can be used for the characteristic ratio assignment(cra) [], [] with frequency response requirements, which is a method of designing linear controller in parameter space. Keywords: Asymptotes, Bode magnitude plot, break frequency, characteristic ratio. Introduction In the classical frequency response design using Bode plot, there are many cases that it is more convenient to use the asymptotes of frequency magnitude response and break point frequencies (which is sometimes called as corner frequency) instead of the exact Bode plots. In addition to the frequency response requirements, if we have to consider transient response specifications as like overshoot and the speed of response, the problem may not be easily carried out by using the conventional Bode plot. A reason is that the precise relationship between pole-zero locations of a system and its transient response is not yet known except for the case of a second order system. As different methods for directly dealing with time response problems, the characteristic ratio assignment [], [], [3] and the coefficient diagram method (CDM) [4] have been studied since the mid of 99. These methods have been developed by expanding relationships between time response of an all pole system and the characteristic ratios and a generalized time constant, which are defined as functions of coefficients of transfer function. This idea was originally investigated by Naslin [5] in 96 but has not been paid attention so much until Manabe [4] invented the CDM. It is important to note that (i) the characteristic ratios are closely related to the damping and the stability, and (ii) the speed of response is exactly characterized by the generalized time constant. Some of them have been proved recently by Kim []. It was shown in [], [], [3], [4] that the CRA and CDM are very useful for the problem of designing a controller that meets the time response requirements. First of all, it is remarkable that all the design procedures of CRA/CDM are carried out in parameter space. However, it is not adequate to apply both CRA/CDM directly to the design problem with frequency response specifications. In [5], Naslin also advocated that for a well damped all pole system, the points of intersection of the pseudo-asymptotes of its frequency magnitude are equal to the characteristic pulsatances. The pulsatances are defined by ratios of adjacent two coefficients of a polynomial. This is a simple method to draw an asymptotic gain diagram. Furthermore, this may be applied to the CRA and the CDM for the sake of considering the frequency response requirements. However, according to our observations, the pulsatances do not coincide with the real break points in the case of which the transfer function has either under-damped complex poles and zeros or multiple ones. In other words, when we use the pulsatances as pseudo break points, it must be restrictively applied to merely the well damped systems. This paper starts from this point. Consider a loop transfer function L(s) N(s)/D(s). From L(jw) N(jw)N( jw)/d(jw)d( jw), each term of L(jw) can be plotted separately. The modulus of the term in w gives a straight line of slope. Similarly, the term in w k is represented by a straight line of slope k. We shall call these straight lines the pseudo asymptotes. Those lines intersect each other. Here the points of intersection are defined by new pseudo break points, which are finally represented in terms of the characteristic ratios and a generalized time constant of denominator and numerator polynomials individually. We will show through several comparative examples that the pseudo asymptotes coincide with real Bode plot for most cases of transfer functions. It is also shown that new pseudo break points are closely identical to the real corner frequencies well.. Asymptotes of Bode magnitude curve In this section, we first give several definitions and then represent a new asymptote of the Bode magnitude plot... Definitions and Motivation The following definitions have been originally introduced by Naslin [5]. Consider a polynomial with real positive coefficients: δ(s) δ ns n + δ n s n + + δ s + δ, δ i >. () The characteristic ratios are defined as: α δ δ δ, α δ δ δ 3,, α n δ n δ n δ n () and the generalized time constant is defined to be τ : δ δ. (3) The characteristic pulsatances are defined by This research was supported in part by grant R-3--738- from the Basic Research Program of the Korea Science & Engineering Foundation. β δ δ, β δ δ,, β n δn δ n (4)

Here this is called as pulsatance briefly. We then have α β β, α β β,, α n β n β n (5) 5 Bode plots of G(s) and G p (s) in Example G(s) G p (s) The coefficients δ i of δ(s) can also be represented in terms of α i s and τ as follows: [] δ δ τ (6) δ i δ τ i α i α i α3 i 3, for i,, n. (7) αi α i We see that for a given set of values α is, τ, and δ the corresponding polynomial δ(s) is uniquely determined. As mentioned in introduction, all these parameters that are represented in terms of coefficients of the transfer function play very important roles in the CRA/CDM ([], [4]). Naslin [5] has observed that the pulsatances of a well damped polynomial are closely identical to the real break frequencies of Bode plot. We give an example to show how the pulsatances relate to the the pseudo-asymptotes of frequency responses. Example Let us examine two cases: one is the well damped system and the other is not. Consider the following transfer function. G(s) (s/.5 + )(s/ + )(s/ + ).5s 3 +.5s +.55s +. According to (4), pulsatances of the denominator are β [β β β ] [.39.667.5]. It is seen that the pulsatances are very similar to the values of real break points of G(s). We can also construct the corresponding transfer function with the pulsatances as follows: G p (s) (s/β + )(s/β + )(s/β + ). As shown in Fig., Bode plots of the G(s) and G p(s) coincide with each other. Secondly, the following transfer function is the case including complex poles and zeros. T (s) (s/) +.4s/ + (s/.5 + )(s/3 + )[(s/5) +.8(s/5) + ].s +.4s +.667 4 s 4 +.6s 3 +.744s +.3493s +. The pulsatances of numerator and denominator of T (s) are Numerator : [β N β N ] [7.49 4] Denominator : [β D β D β D β D 3 ] [.46 3.335 43.5 6.74] Constructing the transfer function whose poles and zeros are equal to βi N and βj D, it becomes T p(s) (s/β N + )(s/β N + ) (s/β D + )(s/βd + )(s/βd + )(s/βd 3 + ). Bode plots of T (s) and T p (s) are shown in Fig.. There are some errors near complex modes between T (s) and T p(s). [Degree] 5 3 log Fig.. Bode plots of G(s) and G p (s) in Example. [] [Degree] 4 6 Bode plots of T(s) and T(p(s) in Example 8 3 5 5 log T(s) T p (s) Fig.. Bode plots of T (s) and T p (s) in Example. This difference becomes larger in the case where the complex poles and zeros are closely placed. In [4], [5],they have addressed that the pulsatances are very useful for drawing the approximate frequency response plot and then can be applied to the design procedure like the CDM although it may have large error in some cases. Because the pulsatances are ratio of two adjacent coefficients of polynomial, it is very easy to tune the controller parameters so that meets the given frequency requirements. However, if the plant has poor damping, the design approach based on the pulsatances may result in unsatisfactory controller due to large approximation error... New pseudo-break frequency Now, we represent a new pseudo-break frequency. As the first step to proceed this, let us consider the following all

pole transfer function of order n. Real magnitude and Asymptotes of G(j) in Example G(s) N(s) D(s) a a ns n + a n s n + + a s + a. (8) G G G 3 G 4 w p w p w w p p3 The frequency magnitude can be given by G(jw) G G(j) G(j)G( j) 4 a c n n +c n (n ) + +c +c. (9) 6 Taking the logarithm on both sides of (9), it becomes where log( G(j) ) log(a ) log( D(j) ), () log D(j) log(c n n + c n (n ) + + c + c ). Here we define the asymptote of () as follows: () log D(j) log D(j) p : log c +log c + +log c n n. () Every terms in right hand side of () are straight lines with slopes,,,, which we will call the pseudo-asymptotes. The unit of this slope is 6[/Oct] or [/Dec]. Then the intersection of each two adjacent lines is defined as the pseudo-break frequency. From () p : c c, p : c c,, pn : cn c n. (3) The following Example shows pseudo-break frequencies and pseudo-asymptotes of an all pole transfer function. Example Consider the following transfer function. G(s) N(s) D(s) 545 (s + )(s + 5)(s + + j3)(s + j3) 545 s 4 + 6s 3 + 34s + 754s + 545. Then we have c a 545, c a a + a 559.87, c a + a a 3 a 8.99, c 3 a 3 a 4, 4, c 4. Using (3), we obtain the pseudo-break points. [ p p p p3 ] [.97 4.34 8.94 4.4]. We see that the pseudo-break frequencies are very similar to the real break points. The pseudo-break frequencies and the pseudo-asymptotes have been depicted in Fig. 3 where G k : log(a ) log c k k, k,,, 4. Now our problem is to express the pseudo-break points in terms of characteristic ratios and pulsatances. Recall the all pole system in (8) and (9). Define G(j) a D(j)D( j) Q () (4) 8 Fig. 3. Real magnitude curve and asymptotes of G(s) in Example. { Π j j i : ki,i<j α k, if < i < j α i, if < i j. Using (6), (7), and (5), where Q () + η τ + η τ ( ) 4 4 + η 3τ ( 6 ) 6 + + ( η k : α k + η n τ n 3 n α k k+ k (5) ) n (6) α k k+ k k+ k + +( ) k. (7) α k Π k j k+j k j If we draw the approximated curve of G(j) vs. frequency by plotting each term in (6) with pseudo-asymptotes, a typical shape is as shown in Fig. 4. G(jw) [] Fig. 4. l l l l 3 τ p p p p3-6/oct log [rad/sec] Pseudo-asymptotic diagram of G(j). From () and (3), the pseudo-break points in (6)are identical to pi : ηi where η and. Let then we may write i, i,,, n. (8) η i+ τ l i : log pi log p(i ), (9)

l (log τ + ) log η () l i log η i (log ηi + log ηi+) + log αi, () where i,,, n. Remark It has been observed from eq.(7) that η i η i+ for i,,, n as α i increases sufficiently larger than. Under this condition, then l i log α i and pi < p(i+) for all i. It results that the pseudo break points pi lie in the form of sequential line-up. Since the time domain responses of a strictly proper system are dominantly related to the frequency magnitude at lower frequency than that of which the magnitude has about [db], we know that three values of l, l, l and l 3 play a significant role in the responses. Consequently, α, α, α 3 and τ have much greater influence than the rest. Indeed, α, α and α 3 are the most dominant factors dictating the size of overshoot while τ can be used approximately to consider bandwidth or speed of response [6]. The main concept of pseudo-break frequency that has been introduced for all pole transfer function so far can be extended to the general case. Let us consider N(s) of degree m. Since G(j) N(j)N( j), we have D(j)D( j) log( G(j) ) log( N(j) ) log( D(j) ), () where log( D(j) ) is the same as () and log N(j) log(f m m +f m (m ) + +f +f ). Then we can define the asymptote of () as follows: log G(j) log G(j) p : log N(j) p log D(j) p {log f + log f + + log f m m } (3) {log c + log c + + log c n n }. (4) The pseudo-break points of numerator are separately defined in the similar way as those of denominator. 3. Comparative examples In this section, we will give several examples to evaluate the proximity of new pseudo-break frequency and pseudoasymptotes by comparing with the real values. The nearness of pulsatances defined by Naslin will be also compared with true systems in the same examples. Example 3 (The case of no zero and distinct, real poles) Consider the all pole transfer function T (s) with unit DC gain whose poles are.5, 3, 5, 5,, 3, 5 Real break points, pseudo-break point and pulsatances of this transfer function are provided in Table. Fig. 5 shows their Bode magnitude curves. It is seen that Both break points and asymptotes closely approximate the actual values in this well damped case. Table. Different break frequencies of T (j) in Ex. 3. k points( k ) points( pk ) (β k ).5.493.4 3.976.684 3 5 4.49. 4 5 46.5 39.67 5 4.99 8. 6 3 75.94 3.5 7 5 593.9 968.5 3 4 5 6 7 8 Magnitude responses of T(j) with n7 True(solid) Fig. 5. Bode magnitude plots and asymptotes of T (s) in Ex. 3. Example 4 (The case of no zero and three real plus two pairs of complex poles) Consider the following transfer function T (s) 7.34 7 (s + )(s + )(s + 3)(s + 6s + 64)(s + 5s + 75). Real break points, pseudo-break point and pulsatances of T (s) are provided in Table. Fig. 6 shows their Bode magnitude curves. We can see through Table and Fig. 6 that the pseudo-break points and pseudo-asymptotes approximate more closely than those of pulsatances in this case. Table. Different break frequencies of T (j) in Ex. 4. k points( k ) points( pk ) (β k ).96.5 9.4 4. 3.8 9.9 8.9 4.8 6.46 4. 5 6.93 9. 4.5 6 6.93 7.99 44.8 7 3 44.5 8 Example 5 (The case of no zero and 7 poles distributed around a circle in s-plane) Consider the transfer function T 3 (s) with unit DC gain whose poles are.45, 7.3495 ± j7.3649, 9.5887 ± j4.39, 4.936 ± j9.659.

Magnitude responses of T(j) with n7 Magnitude responses of T(j) with n7 3 3 4 4 5 5 6 6 7 8 True(solid) Fig. 6. Bode magnitude plots and asymptotes of T (s) in Ex. 4. 7 8 True(solid) Fig. 8. Bode magnitude plots and asymptotes of T 3 (s) in Ex. 5. The pole locations of T 3(s) are depicted in Fig. 7. Real break points, pseudo-break point and pulsatances of T 3 (s) are provided in Table 3. Fig. 8 shows their Bode magnitude curves. We can see through Table 3 and Fig. 8 that the pseudo-break points and pseudo-asymptotes approximate much more closely than those of pulsatances in this case. Imaginary Axis 8 6 4 4 6 8 Pole Zero Map 5 5 Real Axis 5 As shown in Table 4 and Fig. 9, the pseudo break frequencies and pseudo-asymptotes result in satisfactory approximation. However, the error between real values and those by pulsatances over the middle frequency range are significantly larger than 3 []. This is also verified by the Bode plots of three transfer functions which are generated on the basis of pseudo-break points and pulsatances respectively as shown in Fig.. Table 4. Different break frequencies of T 4 (j) in Ex. 6. k points( k ) points( pk ) (β k ) 6 5.76 3.86 Num. 8.3 6.9 4.3 3 8.3. 36.96.5 9.46 4. 3.86 9.9 8.9 Den. 4.86 6.46 4. 5 6.96 9.6 4.5 6 6.96 7.99 44.84 7 3 44.5 8 Fig. 7. Pole diagram of T 3 (s) in Ex. 5. Magnitude responses of T(j) with n7 Table 3. Different break frequencies of T 3(j) in Ex. 5. k points( k ) points( pk ) (β k ).45 8.94.45 9.65 4. 3.45 9.6 6.857 4.45.45.45 5.45.5 5.79 6.45.8 45.78 7.45. 54.3 3 4 5 6 7 True 8 3 Fig. 9. Bode magnitude plots and asymptotes of T 4 (s) in Ex. 6. Example 6 (The case of 3 zeros and 7 poles) Here we consider a transfer function T 4 (j) including three zeros with unit DC gain. Its zeros and poles are Zeros : 6, 5 ± j Poles :,, 3, 8 ± j, 5 ± j. 4. Concluding remark In the standard Bode plot, the break points between asymptotic straight lines are composed of poles and zeros of the transfer function. As like the usefulness of parametric stability criteria [4], [7], if there are any methods that will be able

[] 3 4 References [] Y.C. Kim, L.H. Keel, and S.P. Bhattacharyya, Transient response control via characteristic ratio assignment, IEEE Trans. on Automatic Control, vol. AC-48, no., pp.38-44, Dec. 3. [] Y.C. Kim, L.H. Keel, and S. Manabe, Controller design for time domain specification, Proc. of IFAC World Congress, Barcelona, Spain, July,. [3] K.S. Kim, Y.C. Kim, L.H. Keel, and S.P. Bhattacharyya, PID controller design with time response specifications, Proc. of 3 American Control Conf., Denver, USA, June, 3. [4] S. Manabe, Coefficient diagram method, Proc. of the 4th IFAC Symp. on Automatic Control in Aerospace, pp.99-, Seoul, Korea, 998. [5] P. Naslin, Essentials of Optimal Control, Boston Technical Publishers, Inc., 969. [6] Youngchol Kim, Keunsik Kim and S. Manabe, Sensitivity of time response to characteristic ratios, Proc. of 4 American Control Conf., pp.73-78, Boston, USA, June, 4. [7] S.P. Bhattqacharyya, H. Chapellat and L.H. Keel, Robust Control: The Parametric Approach, Prentice Hall Inc., 995. 5 [degree] 3 True Pseudo break point Pulsatance Fig.. Bode plots of T 4 (s), T 4pseudo (s), T 4pulsa (s) in Ex. 6. to estimate the break points directly from the coefficients of transfer function instead of roots, such methods will be very useful for some classical controller design problems with frequency performance specifications. For the sake of this purpose, we have introduced a new pseudo-break point which is defined in terms of only the coefficients of transfer function. Through comparative studies of the pseudo-break point and the pulsatance defined by Naslin, it has been showed that the approximation errors by the pseudo-break points are not larger than about 3 [] and that the proposed one provides much more effective approximation than that of the pulsatance. However, the pulsatance is easier to use than the pseudo-break point in applications since it is simply defined by the ratio of adjacent two coefficients.