ECE 486 Control Systems

Similar documents
If you need more room, use the backs of the pages and indicate that you have done so.

Homework 7 - Solutions

Controls Problems for Qualifying Exam - Spring 2014

Frequency Response Techniques

EECS C128/ ME C134 Final Thu. May 14, pm. Closed book. One page, 2 sides of formula sheets. No calculators.

Systems Analysis and Control

MAS107 Control Theory Exam Solutions 2008

Control Systems I. Lecture 9: The Nyquist condition

Systems Analysis and Control

ELECTRONICS & COMMUNICATIONS DEP. 3rd YEAR, 2010/2011 CONTROL ENGINEERING SHEET 5 Lead-Lag Compensation Techniques

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING

Chapter 2. Classical Control System Design. Dutch Institute of Systems and Control

(b) A unity feedback system is characterized by the transfer function. Design a suitable compensator to meet the following specifications:

Systems Analysis and Control

2.004 Dynamics and Control II Spring 2008

Topic # Feedback Control

K(s +2) s +20 K (s + 10)(s +1) 2. (c) KG(s) = K(s + 10)(s +1) (s + 100)(s +5) 3. Solution : (a) KG(s) = s +20 = K s s

Root Locus Methods. The root locus procedure

r + - FINAL June 12, 2012 MAE 143B Linear Control Prof. M. Krstic

IC6501 CONTROL SYSTEMS

MAE 143B - Homework 9

R a) Compare open loop and closed loop control systems. b) Clearly bring out, from basics, Force-current and Force-Voltage analogies.

Plan of the Lecture. Goal: wrap up lead and lag control; start looking at frequency response as an alternative methodology for control systems design.

DESIGN USING TRANSFORMATION TECHNIQUE CLASSICAL METHOD

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Analysis of SISO Control Loops

AMME3500: System Dynamics & Control

H(s) = s. a 2. H eq (z) = z z. G(s) a 2. G(s) A B. s 2 s(s + a) 2 s(s a) G(s) 1 a 1 a. } = (z s 1)( z. e ) ) (z. (z 1)(z e at )(z e at )

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering Dynamics and Control II Fall K(s +1)(s +2) G(s) =.

Methods for analysis and control of. Lecture 4: The root locus design method

I What is root locus. I System analysis via root locus. I How to plot root locus. Root locus (RL) I Uses the poles and zeros of the OL TF

STABILITY OF CLOSED-LOOP CONTOL SYSTEMS

CHAPTER 7 : BODE PLOTS AND GAIN ADJUSTMENTS COMPENSATION

ECE 345 / ME 380 Introduction to Control Systems Lecture Notes 8

EECS C128/ ME C134 Final Wed. Dec. 14, am. Closed book. One page, 2 sides of formula sheets. No calculators.

Robust Control 3 The Closed Loop

1 (20 pts) Nyquist Exercise

Systems Analysis and Control

The loop shaping paradigm. Lecture 7. Loop analysis of feedback systems (2) Essential specifications (2)

ROOT LOCUS. Consider the system. Root locus presents the poles of the closed-loop system when the gain K changes from 0 to. H(s) H ( s) = ( s)

a. Closed-loop system; b. equivalent transfer function Then the CLTF () T is s the poles of () T are s from a contribution of a

Methods for analysis and control of dynamical systems Lecture 4: The root locus design method

Frequency methods for the analysis of feedback systems. Lecture 6. Loop analysis of feedback systems. Nyquist approach to study stability

Outline. Classical Control. Lecture 1

Digital Control Systems

ECE382/ME482 Spring 2005 Homework 7 Solution April 17, K(s + 0.2) s 2 (s + 2)(s + 5) G(s) =

Control Systems. Root Locus & Pole Assignment. L. Lanari

Course Outline. Closed Loop Stability. Stability. Amme 3500 : System Dynamics & Control. Nyquist Stability. Dr. Dunant Halim

Boise State University Department of Electrical Engineering ECE461 Control Systems. Control System Design in the Frequency Domain

Step input, ramp input, parabolic input and impulse input signals. 2. What is the initial slope of a step response of a first order system?

1 (s + 3)(s + 2)(s + a) G(s) = C(s) = K P + K I

School of Mechanical Engineering Purdue University. DC Motor Position Control The block diagram for position control of the servo table is given by:

INTRODUCTION TO DIGITAL CONTROL

SECTION 5: ROOT LOCUS ANALYSIS

100 (s + 10) (s + 100) e 0.5s. s 100 (s + 10) (s + 100). G(s) =

R10 JNTUWORLD B 1 M 1 K 2 M 2. f(t) Figure 1

EECS C128/ ME C134 Final Wed. Dec. 15, am. Closed book. Two pages of formula sheets. No calculators.

7.4 STEP BY STEP PROCEDURE TO DRAW THE ROOT LOCUS DIAGRAM

Module 07 Control Systems Design & Analysis via Root-Locus Method

Lecture 15 Nyquist Criterion and Diagram

Classify a transfer function to see which order or ramp it can follow and with which expected error.

MAE 143B - Homework 8 Solutions

MEM 355 Performance Enhancement of Dynamical Systems

Control Systems I. Lecture 9: The Nyquist condition

CYBER EXPLORATION LABORATORY EXPERIMENTS

Root Locus Techniques

EE3CL4: Introduction to Linear Control Systems

Problems -X-O («) s-plane. s-plane *~8 -X -5. id) X s-plane. s-plane. -* Xtg) FIGURE P8.1. j-plane. JO) k JO)

Lecture 6 Classical Control Overview IV. Dr. Radhakant Padhi Asst. Professor Dept. of Aerospace Engineering Indian Institute of Science - Bangalore

Module 3F2: Systems and Control EXAMPLES PAPER 2 ROOT-LOCUS. Solutions

Outline. Classical Control. Lecture 5

FREQUENCY-RESPONSE DESIGN

Systems Analysis and Control

Nyquist Criterion For Stability of Closed Loop System

16.30/31, Fall 2010 Recitation # 2

Control Systems Engineering ( Chapter 8. Root Locus Techniques ) Prof. Kwang-Chun Ho Tel: Fax:

Übersetzungshilfe / Translation aid (English) To be returned at the end of the exam!

Software Engineering 3DX3. Slides 8: Root Locus Techniques

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering 2.04A Systems and Controls Spring 2013

Dr Ian R. Manchester Dr Ian R. Manchester AMME 3500 : Review

Compensation 8. f4 that separate these regions of stability and instability. The characteristic S 0 L U T I 0 N S

Automatic Control (MSc in Mechanical Engineering) Lecturer: Andrea Zanchettin Date: Student ID number... Signature...

Prüfung Regelungstechnik I (Control Systems I) Übersetzungshilfe / Translation aid (English) To be returned at the end of the exam!

MEM 355 Performance Enhancement of Dynamical Systems

ME 475/591 Control Systems Final Exam Fall '99

MAE 143B - Homework 9

EE C128 / ME C134 Fall 2014 HW 6.2 Solutions. HW 6.2 Solutions

EE 380 EXAM II 3 November 2011 Last Name (Print): First Name (Print): ID number (Last 4 digits): Section: DO NOT TURN THIS PAGE UNTIL YOU ARE TOLD TO

Transient response via gain adjustment. Consider a unity feedback system, where G(s) = 2. The closed loop transfer function is. s 2 + 2ζωs + ω 2 n

CHAPTER # 9 ROOT LOCUS ANALYSES

Theory of Machines and Automatic Control Winter 2018/2019

ECEN 605 LINEAR SYSTEMS. Lecture 20 Characteristics of Feedback Control Systems II Feedback and Stability 1/27

Some special cases

Compensator Design to Improve Transient Performance Using Root Locus

Dr Ian R. Manchester Dr Ian R. Manchester AMME 3500 : Root Locus

Example on Root Locus Sketching and Control Design

Robust Performance Example #1

Raktim Bhattacharya. . AERO 422: Active Controls for Aerospace Vehicles. Frequency Response-Design Method

Unit 11 - Week 7: Quantitative feedback theory (Part 1/2)

Chapter 7 : Root Locus Technique

Transcription:

ECE 486 Control Systems Spring 208 Midterm #2 Information Issued: April 5, 208 Updated: April 8, 208 ˆ This document is an info sheet about the second exam of ECE 486, Spring 208. ˆ Please read the following information carefully and start/continue studying the second exam. * * * * * ˆ When and where is the exam taking place? The second midterm will be held on Thursday, Apr 2, in class from 9:30 a.m. 0:50 a.m. There is no conflict exam offered at any other time. For those who cannot make it for legitimate reasons, for each exam that is skipped, their final exam will be reweighted with an additional 5% of the course grade. For example, skipping this exam will make the final count as 40%. ˆ What topics will be covered? Everything covered in Lecture 9 through 8 is a fair game. That is everything from Root Locus design to Nyquist Stability Criterion; see lecture matrix for details. https://courses.engr.illinois.edu/ece486/sp208/lectures/ Here is a list of specific topics: All rules for plotting the positive root locus; Positive vs. negative root loci (0 vs. 80 root loci); Choosing the gain for pole placement using root locus Design using root locus method: PD and lead control, PI and lag control, lead+lag control Bode magnitude and phase plots Bode plots and stability, gain and phase margins; Bodes gain-phase relationship (as design guideline, not the exact integral relationship) Relations between properties of the open-loop Bode plot (phase margin, crossover frequency) and properties of the closed-loop system (damping ratio, overshoot, bandwidth) Frequency response design method: PD and lead control, PI and lag control, lead+lag control

Nyquist plots and Nyquist stability criterion (proof via argument principle not tested on the exam) ˆ What to bring during the exam? The exam is closed-book, closed-notes. You may bring one sheet (double-sided, letter size 8.5 inch) of notes with any necessary formulas. A simple calculator without symbolic computation is allowed. ˆ Any tips for studying the exam? The primary goal of the exam is to test your understanding of the main concepts, not memorization or computational skills. Make sure you can follow all the lecture material, readings, and homework problems and solutions. On the next page, an exam from a past semester is given as a sample. An outline of solutions to this sample exam will be posted is posted alongside the sample exam on the course website this weekend before our exam. Disclaimer: The exam this semester will be significantly different in style and content from that older one. ˆ Is there any extra office hours? There is a one-hour session of extra office hours on Wednesday, April, 2 p.m. p.m. in 3034 ECEB on top of the normal office hours the following hour at the same location. typeset with AMS-L A TEX 2

ECE 486, Spring 208 Sample Midterm #2 Thursday, Apr 5th. Problem : Consider the following transfer function G(s) = (s )(s + 3)(s + 5). Fill in the information below and sketch the root locus of + KG(s). (a) Angles of asymptotes (b) Origin of asymptotes (c) Range of K for stability Solution: Let n be the degree of the denominator of G(s) and m the degree of the numerator of G(s). We have n = 3, m = 0. (a) From lec.html, by Rule E, the angles of asymptotes are given by s 80 + l 360 n m (2l + ) 80 =, l = 0,,..., n m. n m So the angles are 60, 80 and 300. (b) By the additional notes on root locus at the beginning of lec2.html, the origin of asymptotes is given by n i= α = p i m j= z j. n m + ( 3) + ( 5) Therefore the origin is = 7 3 0 3. (c) The characteristic polynomial is (s )(s + 3)(s + 5) + K = s 3 + 7s 2 + 7s + K 5. By Example 3 from lec07.html, for a third order polynomial to be stable, we need 7 > 0, K 5 > 0, 7 7 > K 5. Hence 5 < K < 64. Better use an alternative here. Evaluate the characteristic polynomial at s = jω to get the jω-crossing and the critical K at the same time, i.e., (jω) 3 + 7(jω) 2 + 7(jω) + K 5 = 0 = ( 7ω 2 + K 5) + j(7ω ω 3 ) = 0. Again K critical = 64 and root locus crosses ±jω = ±j 7 on the imaginary axis. 3

Im (seconds - ) (d) On top of the three pieces of information above already calculated, we need to decide the real locus and breakaway point. i. The real locus is given by (, 5] [ 3, ] by testing the total number of open-loop zeros and poles to the right of a point on the real axis. If the total number of zeros and poles is odd, then the point belongs to the real locus. ii. The breakaway point is obtained by solving dg(s) = 0, which gives s = ds 0.569. The root locus sketch of + KG(s) is shown below. 2. Problem 2: Sketch the asymptotic Bode Re (seconds magnitude - ) plots for the following transfer functions. 8s(s + 2) (a) G(s) = (s + 6). 2 Solution: Write G c (s) in Bode form, G c (s) = 8 2 36 s(s 2 + ) ) 2 6 + = s 2 + ) 6 + ) 2. Giving straight lines as the asymptotic indicators is enough. 4

Magnitude (db) Magnitude (db) 30 20 0 slope = +2 slope = 0 0 slope = + -0-20 2 6 8(s + 2) (b) G(s) = s(s 2 + 5s + 36). Solution: Similar to (a), use straight lines as Bode sketch for G c (s) in Bode form, G c (s) = s (s 2 + ) ) 2 5 ). + + 6 6 6 40 20 slope = - Frequency (rad/s) 0-20 -40-60 slope = 0 2 6 slope = -2 3. Problem 3: Consider the unity negative feedback loop with plant G p (s) = s(s + 2). Design a Lead Compensator G c (s) such that the closed-loop system has a pair of poles at s = 4. Solution: Consider a Lead Compensator of the form G c (s) = K s + z. We can use Frequency (rad/s) s + p s + z = s + 2 to cancel out the open-loop pole s = 2 so that the resulting closed-loop system is second order. Then the characteristic equation becomes + KG c (s)g p (s) = + K s(s + p). The resulting characteristic polynomial is s 2 + ps + K. Matching the desired characteristic polynomial (s + 4) 2 = s 2 + 8s + 6, we obtain { p = 8, K = 6. 5

Phase (deg) Magnitude (abs) So one possible Lead Compensator is G c (s) = 6 s + 2 s + 8. 4. Problem 4: Consider the given Bode plot of some open-loop transfer function G(s). G(s) does not have repeated poles at origin. 0 3 0 2 0 0 0 0-0 -2 0-3 -90-35 -80-225 -270 0-2 0 0 0 2 Frequency (rad/s) Based on the figure, answer the following questions. (a) Why does the phase plot start out at 270 at low frequencies? Circle one of the possible reasons from below. i. G(s) has a pole at s = 270. ii. G(s) has a zero at s = 270. iii. G(s) has one RHP open-loop pole. iv. The phase margin is 270. Solution: G(s) does not have repeat poles at origin, but G(s) may have a simple pole at origin s = 0. This factor contributes phase s 90 initially at low frequencies. Further notice that a factor associated with one RHP open-loop pole contributes phase 80 at low frequencies. Therefore the transfer function has the form G(s) = where s = p is an unstable open-loop pole. s(s p), (b) If we enclose the open-loop transfer function G(s) with negative unity feedback with scalar gain K =, based on the given Bode plot, is this closed-loop system stable? Why or why not? 6

Solution: With K =, the Bode plot of the equivalent open-loop transfer function (forward path) KG(s) is the same as the Bode plot of G(s). By the given Bode plot of G(s), the phase at crossover frequency is between 35 and 80, hence a positive phase margin (PM > 0 ). The closed-loop system is stable. (c) As a follow-up question to (b), if we lower K to, is this closed-loop system 00 stable? Why or why not? Solution: Similar to (b), read the phase of G(s) at the frequency where the magnitude is 00, the phase is between 225 and 80. Hence the PM of KG(s) = G(s) is less than 00 0. The closed-loop system is not stable. (d) (Bonus question) Sketch the Nyquist plot of G(s) based on its given Bode plot, then answer the question in (b) using Nyquist stability criterion and your answer in (a). Justify your answer. Solution: Based on the Bode plot of G(s), the magnitude keeps shrinking as ω increases from 0 + to +. By the phase plot, it crosses the negative portion of real axis once. Most importantly, when it crosses the real axis, the magnitude is greater than. The crossing is on the left of. It ends at origin with arriving angle 80. One possible Nyquist plot (generated using G(s) = 00 s 0 + s s(s ) +) is shown above. 00 By (a), there is one RHP open-loop pole, so P =. Encirclement of Nyquist plot of G(s) about is anticlockwise, so N =. Then by the Nyquist Stability Criterion from lec8.html, the number of RHP closed-loop poles is Z = N + P = 0. The closed-loop system is stable, the same as in (b). 7