Figure 1 Enlargement of Powdered Activated Carbon by microscope.

Similar documents
Dry sorption with sodium bicarbonate Really a very simple. Examinations at a waste incinerator in France

Applied Fluid Mechanics

Control Your Product Quality by Controlling Your Product's Conveying Velocity

MSWI Flue Gas Two-Stage Dry Treatment: Modeling and Simulation

High-Pressure Volumetric Analyzer

Exercise 4-4. Titration of a Buffer Solution EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Buffer solutions

the foundation of any business starts here

1) Batching Methods (Add Weigh or Loss In Weight) based on batch dispensing time, time between batches, head room, floor space, accuracy and budget.

M E 320 Professor John M. Cimbala Lecture 23

Rotary modules.

Technical Explanation for Axial Fans

REPAIR PARTS. DX17VS Outdoor Inverter. This manual is to be used by qualified technicians only.

5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

Measurement of Dust Cloud Characteristics in Industrial Plants 1

Gravimetric coal dust firing and dry lignite firing in power plants

STATE OF COLORADO DESIGN CRITERIA FOR POTABLE WATER SYSTEMS WATER QUALITY CONTROL DIVISION. Price: $5.00. Revised March 31, 1997

How to Check Your G4 Spread Pattern

Applied Fluid Mechanics

Accumulators Virginia KMP Suction Line Accumulators

APPENDIX C VTM - 40, TITRATION & CEMENT PLANT CALIBRATION

Applied Fluid Mechanics

PF-FLO REFERENCE TEST AT THE MARTIN-LUTHER UNIVERSITY HALLE-WITTENBERG

Chemistry Instrumental Analysis Lecture 31. Chem 4631

VOLUMEC. Valve Position Indicator 5

SKF actuators available for quick delivery. Selection guide

Methods of pollution control and waste management - laboratory. Adsorptive removal of volatile organic compounds from gases streams

Thermochemistry/Calorimetry. Determination of the enthalpy of vaporization of liquids LEC 02. What you need: What you can learn about

Mixing Process of Binary Polymer Particles in Different Type of Mixers

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH

Exercise 2-2. Titration of a Strong Acid EXERCISE OBJECTIVES

Electrolysis System CHLORINSITU V (PLUS)

AMRITA VISHWA VIDYAPEETHAM DEPARTMENT OF CHEMICAL ENGINEERING AND MATERIALS SCIENCE. PhD Entrance Examination - Syllabus

Evaluating New Generation Vibrating Tube Sensor for Density Measurement under Process Conditions

Use of Near Infrared Spectroscopy for in- and off-line performance determination of continuous and batch powder mixers: opportunities & challenges

Phone: , For Educational Use. SOFTbank E-Book Center, Tehran. Fundamentals of Heat Transfer. René Reyes Mazzoco

Exercise 2-4. Titration of a Buffer Solution EXERCISE OBJECTIVES

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

EXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER

Experimental Study of Temperature Variations in Fluidized Beds

Introduction to Actuators PK

CHEMICAL ENGINEERING

Exercise 4-3. Titration of Weak Acids EXERCISE OBJECTIVE DISCUSSION OUTLINE. The 5% rule DISCUSSION

Importance of in situ Monitoring in MOCVD Process and Future Prospects

COURSE CODE : 3072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE

Experimental Investigation of Transient Hydrodynamic Forces of a Single-Blade Centrifugal Pump

THEORETIC AND EXPERIMENTAL RESEARCH ON THE CHARACTERISTIC DIAGRAMS OF A NEW TYPE OF ROTATING MACHINE WITH PROFILED ROTORS

ADSORPTION. Briefly, adsorption is the surface accumulation of material.

Two mark questions and answers UNIT I BASIC CONCEPT AND FIRST LAW SVCET

Glossary of Common Laboratory Terms

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

1. Introduction. Technical presentation of the Bernoulli Filter

Contents. Preface... xvii

Advanced Chemical Reaction Engineering Prof. H. S. Shankar Department of Chemical Engineering IIT Bombay. Lecture - 03 Design Equations-1

EXECUTIVE SUMMARY. especially in last 50 years. Industries, especially power industry, are the large anthropogenic

An Introduction to Air Pollution

COMBUSTION OF FUEL 12:57:42

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Instruction Manual. Equipment for Engineering Education

nufacturing Company, L.P San Felipe, Suite

HYGROSCOPIC BULK SOLIDS Reliable handling of bulk solids based on know-how.

Exercise 5-1. Water Deionization EXERCISE OBJECTIVE DISCUSSION OUTLINE. Introduction DISCUSSION. An ions story

costech instruments ECS 4010 Elemental Combustion System CHNS-O

FEATURE ARTICLE. The CS-100 Series High-precision Chemical Solution Monitor in the Semiconductor Cleaning Process. Takaaki Yada.

Engineering of centrifugal dust-collectors based on parallel comparing tests applying computer modelling

Investigation of Performance of Different Sorbents in a Twostage Flue Gas Dry Treatment of a MSWI

EXPLODED DIAGRAM - PARTS VIEW

Safety Engineering. -Static Electricity and Charge Accumulation-

NATIONAL CERTIFICATE (VOCATIONAL) APPLIED ENGINEERING TECHNOLOGY NQF LEVEL 4 NOVEMBER 2009

THE CERN CRYOGENIC TEST FACILITY FOR THE ATLAS BARREL TOROID MAGNETS

Wet FGD Chemistry and Performance Factors

CHLORINE RECOVERY FROM HYDROGEN CHLORIDE

Separations II: Solid-Gas Systems

LUEHR FILTER. Author: Dipl. - Ing. Rüdiger Margraf. HDT symposium. Dry flue gas cleaning for firing installations and other thermal processes

Facts and figures MULTILIFT SELECT 15

Dear Sirs, MZUTL homogenizing mixers with integrated cover lifting system e.g. 200 liters

The FLUX F 430 with mechanical seal

Advantages of Variable Frequency Drive Technology for Face Conveyor and Plow Systems in Longwall Mining

Numerical Study of the Semi-Open Centrifugal Pump Impeller Side Clearance A. Farid Ayad *, H. M. Abdalla,A. S. Abo El-Azm Egyptian Armed Forces, Egypt

CHEMICAL APPLICATIONS AND CHEMICAL FEED PUMPS. Need for Chemicals. Chemical Applications. Chemical Applications. Chemical Applications

Development of an organometallic flow chemistry. reaction at pilot plant scale for the manufacture of

TABLE OF CONTENT. Chapter 4 Multiple Reaction Systems 61 Parallel Reactions 61 Quantitative Treatment of Product Distribution 63 Series Reactions 65

Experimental Study on NO Removal Using Non-thermal Plasma Oxidation-alkali Absorption

HEAT CONTENT DECREASES U D R HEAT CONTENT INCREASESO. Btu/lb

Lecture 18: Microfluidic MEMS, Applications

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Model Selection 1. Process Valves. Air. Vacuum

Process Development & Scale-Up of the AIR Technology

CHAPTER 6 FAULT DIAGNOSIS OF UNBALANCED CNC MACHINE SPINDLE USING VIBRATION SIGNATURES-A CASE STUDY

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

CHAPTER 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

PID Control of a Batch ph Process with a Strong Acid

Figure 4-1: Pretreatment schematic

B1-1. Closed-loop control. Chapter 1. Fundamentals of closed-loop control technology. Festo Didactic Process Control System

INTRODUCTION TO ISA SYMBOLOGY

Uniform Circular Motion

AMORTIGUADORES DE IMPACTO

Overview of Control System Design

Reprinted from February Hydrocarbon

Transcription:

Introduction The following is a description of how the Powdered Activated Carbon (PAC) dosing system operates. Firstly an overview of how the Semi Dry Reactor and the purpose of carbon injection is described. Following this the process of unloading the PAC into the PAC silo and the transfer of PAC from the silo to the Semi Dry Reactor is discussed. Finally the process of residue recirculation from the baghouse filter back to the Semi Dry Reactor is noted. Purpose of the Semi Dry Reactor The Semi Dry reactor is a reaction container for the sorption of acids to calcium hydroxide as well as the sorption of heavy metals, dioxins and furans to PAC. Sorption Sorption is a fixation of a material by absorption (chemical) and/or adsorption (physical). Absorption Absorption is the process of gas bonding chemically with liquids or solid materials (calcium hydroxide is used to neutralize acids). In the absorption process, substances from a gas or a liquid are absorbed by a solid material. They penetrate inside the solid material. Adsorption Adsorption refers to a physical process in which substances from a gas or a liquid attach to the surface of solid material and accumulate on that surface. The larger the surface of the solid material, the more adsorption takes place. The forces that cause these substances to deposit on the surface are physical forces rather than forces based on chemical bonding. Powdered Activated Carbon (PAC) The base material for the production of PAC consists of raw materials containing carbon such as brown coal and black coal. Powdered Activated Carbon particles are porous carbon particles with a large internal surface (300 to 2000 square meters per gram) which is formed by macro, transitional and micropores (Figure 1). Figure 1 Enlargement of Powdered Activated Carbon by microscope. Physical reaction Powdered Activated Carbon reacts with organic pollutants and heavy metals such as furans, dioxins and mercury, which are absorbed.

Figure 2 PAC Silo Overview of the PAC path The PAC is delivered by truck (Figure 2). The unloading process is carried out pneumatically using the conveying air created by the trucks on board compressor. The fluidization in the conical section of the silo supports the discharge of PAC from the silo into the metering and conveying system. A metering screw with variable frequency drive meters the PAC. The metering is determined using feedback from the flue gas flow. The rotary valve ensures that a seal is achieved from the silo to the conveying system. The PAC mixes with the conveying air in the injector and is subsequently blown into the reactor and becomes a part of the flue gas. Breather valve The silo is fitted with a breather valve to prevent over and negative pressurization.

Level measurement The level measurement indicates the current level in the silo. A radar measurement device, installed on the silo roof, measures the distance from the reference point (flange gauge on the silo roof) to the product surface (PAC). The radar pulses are sent from the antenna in the instrument, reflected by the product surface and received again by the radar system. Overfill protection measurement The overfill protection measurement is a limit circuit which is independent of the level measurement. It secures the silo from overfill. The measurement device is installed on the silo roof. The system is equipped with a vibration limit switch. The limit switch is fitted with a fork which looks into the silo. The fork oscillates with a certain frequency. When the vibrating fork is covered with PAC, the vibration is damped and the frequency changes. Weighing cells Weighing cells are fitted into the base of the silo. Metering screw The metering screw is a volumetric multi-shaft screw meter. It is fitted with 5 metering screws (Figure 3, item 2), an empty level sensor (Figure 3, item 1) and drive motor standstill monitor (Figure 3, item 3). The level sensor detects the formation of bridges. The metering screws rotate in opposite direction forming a blocking zone. This prevents the solid material from rotating synchronously and ensures a high degree of self-cleaning. The discharge curve is linear. It is continuously adjusted to feed requirements via the frequency converter. Figure 3 Metering Screw The maximum quantities discharged by the PAC metering screws are about 20 kg/h. Metering PAC The metering of PAC corresponds to 40-100 mg/nm 3 flue gas. The frequency of the metering screws depends on the flue gas flow.

Rotary valve for PAC The rotary valve seals the area between the silo and the delivery pipe. Figure 4 Rotary Valve The rotary valve (Figure 4) consists of a rotor with blades turning in a tightly fitting housing. Each rotor cell takes up feed material from the inlet opening and drops it at the valve outlet. This ensures a continuous feed. Semi Dry Reactor The Semi Dry Reactor (Figure 5) is a standing cylindrical container. Lines for the hydrated lime and PAC, the recirculation channels and the water lances enter the bottom of the Semi Dry Reactor. The raw gas flows from the bottom of the reactor to the top where it leaves as a solid material / gas mixture through the reactor head. From there it enters the fabric bag filter. Figure 5 Semi Dry Reactor

Recirculation of Solid Material To better use unreacted hydrated lime and PAC, the separated solid material below the fabric bag filter chambers are primarily conveyed back to the reactor. This conveying occurs with two pneumatic conveyor channels. The conveying and fluidizing air on the different areas of the pneumatic conveying channels can be set and measured with local flow measurements. The conveying/fluidizing air is generated with two conveyor fans. One fan supplies each recirculation channel. There is one redundant air blower which can supply either of the two channels. Safety valves protect the system against excess pressure. The recirculation is constantly kept in motion (flowing bed) through the air injection into the lower part of the fluidization channels. The material is fed into the reactor through the gradient of the channel. Each recirculation channel contains a pneumatically actuated metering rotary valve and a pneumatic shut-off gate valve. Whenever the recirculation of material is stopped, the fluidization of the two channels continues with one blower to keep the material in motion and prevent clogging. Differential pressure control of the material bed in the Semi Dry Reactor The differential pressure of the fluidized material bed in the Semi Dry Reactor is regulated by the recirculation of discharged solid matter from the fabric bag filter. The discharged solid matter is recirculated by one metering rotary valve per channel interface.