arxiv:astro-ph/ v1 15 Sep 2005

Similar documents
arxiv: v1 [astro-ph.im] 2 Apr 2013

arxiv: v1 [astro-ph.im] 15 Apr 2011

Status and Recent Results of the Acoustic Neutrino Detection Test System AMADEUS

arxiv: v1 [astro-ph.im] 29 Nov 2013

Design studies for a neutrino telescope based on optical fiber hydrophones

Output intensity measurement on a diagnostic ultrasound machine using a calibrated thermoacoustic sensor

Ideas for an Interferometric Thermometer

RECENT DEVELOPEMENTS ON FIBER OPTIC AIR-BACKED MANDREL HYDROPHONES

Status and Recent Results of the Acoustic Neutrino Detection Test System AMADEUS of ANTARES. Robert Lahmann ARENA 2014 Annapolis, 09-June-2014

Recent Results of the Acoustic Neutrino Detection Test System AMADEUS

A method to polarise antiprotons in storage rings and create polarised antineutrons

Nuclear Cross-Section Measurements at the Manuel Lujan Jr. Neutron Scattering Center

Cesium Dynamics and H - Density in the Extended Boundary Layer of Negative Hydrogen Ion Sources for Fusion

Digital imaging of charged particle track structures with a low-pressure optical time projection chamber

ACOUSTIC EFFECTS OCCURRING IN OPTICAL BREAKDOWN WITH A LIQUID BY LASER RADIATION

Neutron spin filter based on dynamically polarized protons using photo-excited triplet states

Ion-Acoustic-Wave Instability from Laser-Driven Return Currents

Microwave-induced thermoacoustic tomography using multi-sector scanning

arxiv: v1 [astro-ph.im] 30 Oct 2012

OPTICAL DIAGNOSTICS TO STUDY SUPERCRITICAL CO 2 PROCESSES. A. Braeuer

HARPO: Measurement of polarised gamma rays (1.7 to 72MeV) with the HARPO TPC

physics/ Sep 1997

Measurement of the inelastic neutron scattering cross section of 56 Fe

Geosynchrotron radio emission from CORSIKAsimulated

Proton induced spallation reaction and high power target station

CERN LIBRARIES, GENEVA

GaN for use in harsh radiation environments

Heavy ion fusion energy program in Russia

arxiv:physics/ v2 [physics.ins-det] 18 Jul 2000

HIGH CURRENT PROTON BEAM INVESTIGATIONS AT THE SILHI-LEBT AT CEA/SACLAY

Mara Bruzzi INFN and University of Florence, Italy and SCIPP, UC Santa Cruz, USA

Workshop 2: Acoustic Output Measurements

Measurement of local elastic modulus with CLUE

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

High-power Cryogenic Yb:YAG Lasers and Optical Particle Targeting for EUV Sources *

Nonlinear Optics (NLO)

Charge Collection and Capacitance-Voltage analysis in irradiated n-type magnetic Czochralski silicon detectors

Integrated Modeling of Fast Ignition Experiments

Beam dynamics studies of H-beam chopping in a LEBT for project X

Validity of the Analysis of Radiochromic Film Using Matlab Code

The structure of laser pulses

Stopping power for MeV 12 C ions in solids

Nuclear cross-section measurements at the Manuel Lujan Jr. Neutron Scattering Center. Michal Mocko

High-power Cryogenic Yb:YAG Lasers and Optical Particle Targeting for EUV Sources *

positron source EPOS - general concept - timing system - digital lifetime measurement

Nanoacoustics II Lecture #2 More on generation and pick-up of phonons

Free Electron Laser. Project report: Synchrotron radiation. Sadaf Jamil Rana

On the beam deflection method applied to ultrasound absorption measurements

Preparation of the concerned sectors for educational and R&D activities related to the Hungarian ELI project

PERFORMANCE OF WIRE POSITION SENSORS IN A RADIATION ENVIRONMENT. CERN, Geneva, Switzerland

Performance of the MCP-PMT for the Belle II TOP counter

Precise Measurement of the Absolute Yield of Fluorescence Photons in Atmospheric Gases

Search for a diffuse cosmic neutrino flux with ANTARES using track and cascade events

Measuring the neutrino mass hierarchy with atmospheric neutrinos in IceCube(-Gen2)

LASER SPECTROSCOPIC STUDIES OF NEUTRON-DEFICIENT EUROPIUM AND GADOLINIUM ISOTOPES

Simulation and verification of forces on particles in ultrasound agitated gases

Supplementary Figure S1 Definition of the wave vector components: Parallel and perpendicular wave vector of the exciton and of the emitted photons.

Novel Plastic Microchannel-Based Direct Fast Neutron Detection

The CNGS neutrino beam

Sound radiation of a plate into a reverberant water tank

Investigation of fundamental mechanisms related to ambient gas heating and hydrodynamics of laser-induced plasmas

Determination of parameters of cascade showers in the water calorimeter using 3D-distribution of Cherenkov light

Sensing and Sensors: Fundamental Concepts

Lake Baikal: from Megaton to Gigaton. Bair Shaybonov, JINR, Dubna on behalf of the Baikal Collaboration

Time-resolved measurement of the local equivalence ratio in a gaseous propane injection process using laser-induced gratings

Calorimetry in particle physics experiments

ISOSPIN RESOLVED DOUBLE PION PRODUCTION AT CELSIUS

MAPPING OF ATOMIC NITROGEN IN SINGLE FILAMENTS OF A BARRIER DISCHARGE MEASURED BY TWO PHOTON FLUORESCENCE SPECTROSCOPY (TALIF)

solenoid and time projection chamber for neutron lifetime measurement LINA

Surface Acoustic Wave Linear Motor

Finite Element Modeling of Ultrasonic Transducers for Polymer Characterization

Fast and Slow Ligand Exchange at the Surface of Colloidal Gold Nanoparticles

New measurement of the 62 Ni(n,γ) cross-section with n_tof at CERN

PoS(PSTP 2013)034. Precession Polarimetry at JLab, 6 GeV. G.B. Franklin Carnegie Mellon University

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

LIGHT. ...from laser ion acceleration to future applications. - project overview and lates experimental results -

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

FAST NEUTRON CROSS-SECTION MEASUREMENTS WITH THE NELBE NEUTRON TIME-OF-FLIGHT FACILITY. Postfach D Dresden, Germany

Doppler echocardiography & Magnetic Resonance Imaging. Doppler echocardiography. History: - Langevin developed sonar.

Status of J-PARC Transmutation Experimental Facility

1.E Neutron Energy (MeV)

Hands on LUNA: Detector Simulations with Geant4

VALIDATION OF MIPAS TEMPERATURE DATA WITH THE U. BONN LIDAR AT THE ESRANGE DURING JULY AND AUGUST 2002

Stanford Linear Accelerator Center, Stanford University, Stanford, CA, 94309

MEASUREMENTS OF PARTICULE EMISSION SPECTRA IN PROTON INDUCED REACTIONS OF INTEREST FOR THE DEVELOPMENT OF ACCELERATOR DRIVEN SYSTEMS

NON LINEAR PULSE EVOLUTION IN SEEDED AND CASCADED FELS

VALIDATION OF GOMOS HIGH RESOLUTION TEMPERATURE DATA WITH THE U. BONN LIDAR AT THE ESRANGE DURING JANUARY AND FEBRUARY 2003

SIB 52 - THERMO Stakeholder meeting May 16

STUDY OF THE NEAR THRESHOLD TOTAL CROSS SECTIONS FOR THE QUASI-FREE pn pnη REACTION WITH THE COSY-11 DETECTOR

The interaction of radiation with matter

Modeling of Acoustic Wave Propagation in Layered Solids and Its Application in Heat Assisted Magnetic Recording

2.24 Simulation Study of K L Beam: K L Rates and Background Ilya Larin Department of Physics Old Dominion University Norfolk, VA 23529, U.S.A.

Week 4: Chap. 4 Basic Detector Principles

Evaluation of transverse elastic properties of fibers used in composite materials by laser resonant ultrasound spectroscopy

Technical University of Denmark

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

Radiation damage in diamond sensors at the CMS experiment of the LHC

Ultrasonic Measurement of Minute Displacement of Object Cyclically Actuated by Acoustic Radiation Force

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

Chamber Development Plan and Chamber Simulation Experiments

Transcription:

arxiv:astro-ph/0509450v1 15 Sep 2005 TESTING THERMO-ACOUSTIC SOUND GENERATION IN WATER WITH PROTON AND LASER BEAMS K. GRAF, G. ANTON, J. HÖSSL, A. KAPPES, T. KARG, U. KATZ, R. LAHMANN, C. NAUMANN, K. SALOMON AND C. STEGMANN Physikalisches Institut, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erwin-Rommel-Straße 1, 91058 Erlangen, Germany E-mail: kay.graf@physik.uni-erlangen.de Experiments were performed at a proton accelerator and an infrared laser facility to investigate the sound generation caused by the energy deposition of pulsed particle and laser beams in water. The beams with an energy range of 1PeV to 400PeV per proton beam spill and up to 10EeV for the laser pulse were dumped into a water volume and the resulting acoustic signals were recorded with pressure sensitive sensors. Measurements were performed at varying pulse energies, sensor positions, beam diameters and temperatures. The data is well described by simulations based on the thermo-acoustic model. This implies that the primary mechanism for sound generation by the energy deposition of particles propagating in water is the local heating of the media giving rise to an expansion or contraction of the medium resulting in a pressure pulse with bipolar shape. A possible application of this effect would be the acoustical detection of neutrinos with energies greater than 1 EeV. 1. Introduction The production of hydrodynamic radiation (ultrasonic pressure waves) by fast particles passing through liquids was first predicted already in 1957 leading to the development of the so-called thermo-acoustic model in 1979 1,2. The model allowed to describe the primary production mechanism of the bipolar shaped acoustic signals measured in an experiment with proton pulses in fluid media 3. According to the model, the energy deposition of particles traversing liquids leads to a local heating of the medium which can be regarded as instantaneous with respect to the hydrodynamic time This work is supported by the German BMBF Grant No. 05 CN2WE1/2. 1

2 scale. Due to the temperature change the medium expands or contracts according to its volume expansion coefficient α. The accelerated motion of the heated medium forms an ultrasonic pulse which propagates in the volume. The wave equation describing the pulse is 2 p( r,t) 1 c 2 s 2 p( r,t) t 2 and can be solved using the Kirchhoff integral: p( r,t) = 1 α dv 2 4π r r t 2 ǫ C p V = α C p 2 ǫ( r,t) t 2 (1) ( r,t r r c s ). (2) Here p( r, t) denotes the hydrodynamic pressure at a given place and time, c s the speed of sound in the medium, C p its specific heat capacity and ǫ( r, t) the energy deposition density of the particles. The resulting pressure field is determined by the spatial and temporal distribution of ǫ and by c s, C p and α, the latter three depending on the temperature. A controlled variation of these parameters in laboratory experiments and a study of the resulting pressure signals allows therefore a precise test of the thermoacoustic model. One decisive test is the disappearance of the signal at 4 C in water, the medium considered in the following, due to the vanishing α at this temperature. However, in previously conducted experiments investigating this effect in different liquids, the observed pulses could not be unambiguously verified as thermo-acoustical 3,4,5,6. There the variation of the pulse amplitude with the temperature in water showed not the predicted dependency and particularly not the disappearance of the signal at 4 C. 2. Conducted Experiments The experiments presented in this paper were performed with a pulsed 1064nm Nd:YAG laser facility located at our institute, and the 177MeV proton beam of the Gustaf Werner Cyclotron at the Theodor Svedberg Laboratory in Uppsala, Sweden. The beams were dumped into a 150 60 60cm 3 water tank, where the acoustic field was measured with several position-adjustable hydrophones (pressure sensitive sensors based on the piezo-electric effect). The temperature of the water was varied between 1 C and 20 C with a precision of 0.1 C by cooling and gradual controlled homogeneous reheating of the whole water volume. The spill energy of the proton beam was varied from 10PeV to 400PeV, the beam diameter was approx. 1cm and the spill time 30µs. For 177MeV

3 protons, the energy deposition in the water along the beam axis (z-axis, beamentryintothe wateratz = 0cm)isrelativelyuniformuptoz = 20cm ending in the prominent Bragg-peak at z 22cm. The laser pulse energy was adjusted between 0.1EeV and 10EeV at a beam diameter of a few mm, the pulse length was fixed at 9ns. The laser energy density deposited along the beam axis had an exponential decrease with a absorption length of (6.0±0.1)cm. The two experiments enabled us to use different spatial and temporal distributions of the energy deposition as well as two different kinds of energy transfer into the medium, i.e. by excitation by both beams and additionally by ionisation by the proton beam. The sensors used were characterised and found to be linear in amplitude response, the frequency response was flat up to the main resonance at 50kHz with a sensitivity of approx. 150dBre1V/µPa. The sensitivity dependence on temperature was measured and the relative decrease was found to be less than 1.5% per 1 C. For every set of experimental parameters the signals of 1000 beam pulses were recorded, with a sampling rate of 10MHz, sufficient for the typical frequency range of the signals of 5kHz to 100kHz. 3. Results The measured bipolar signals were found to be in good agreement with simulations based on the thermo-acoustic signal generation mechanism. The hydrodynamic nature of the signal was proven by determining the propagation times of the signals at different positions in the x-direction perpendicular to the beam axis. They were consistent with the expected propagation times for sound in water. Also the investigated signal dependencies on beam energy, beam width and sensor distance from the beam show very good agreement with the simulation based on the thermo-acoustic model. Figures 1 and 2 show the temperature dependence of the peak-to-peak amplitude of the bipolar signals for the two experiments, where a positive (negative) sign denotes a leading positive (negative) peak of the signal. The two data sets shown in each figure were recorded by two sensors positioned at x = 10cm perpendicular to the beam axis and at z = 12cm and z = 22cm along the beam axis, respectively. In the case of the proton beam setup the hydrophone positions correspond roughly to the z-position of the Bragg-peak and a z-position half way between the Bragg-peak and the beam entry into the water, respectively. For comparability, the same positions and the same sensors were chosen for the laser experiment.

4 1.4 hydrophone 1, x=10.0cm, z=12.0cm 1.2 hydrophone 2, x=10.0cm, z=22.0cm amplitude [au] 1 0.8 0.6 0.4 0.2 preliminary 0-0.2 2 4 6 8 10 12 14 16 18 20 temperature [ C] Figure 1. Measured signal amplitude of the bipolar acoustic signal produced by laser pulses at different temperatures fitted with the model expectation as described in the text. All amplitudes were normalised to 1 at 15.0 C. amplitude [au] 0.8 0.6 0.4 0.2 0 1 hydrophone 1, x=10.0cm, z=12.0cm preliminary hydrophone 2, x=10.0cm, z=22.0cm -0.2 2 4 6 8 10 12 14 temperature [ C] Figure 2. Measured signal amplitude of the bipolar acoustic signal produced by proton pulses at different temperatures fitted with the model expectation as described in the text. The non-thermo-acoustic signal at 4.0 C was subtracted at every temperature. The amplitudes were afterwards normalised to 1 at 15.0 C. The laser beam signal shown in Fig. 1 changes its polarity around 4 C, as expected from the thermo-acoustic model. The model expectation for the signal amplitude, which is proportional to α/c p and vanishes at 4 C, is fitted to the experimental data. In the fit an overall scaling factor and a constant temperature shift were left free as fit parameters. The fit yielded a zero-crossing of the amplitude at (3.9±0.1) C, where the error is dominated by the systematic uncertainty in the temperature setting. The zero-

5 crossing is in good agreement with the expectation of 4.0 C. Analysing the proton data in the same way yielded a shape slightly deviating from the model expectation, and a zero-crossing significantly different from 4.0 C at (4.5 ± 0.1) C. In view of the results from the laser beam measurements, we subtracted the residual signal at 4.0 C, which has an amplitude of approx. 5% of the 15.0 C signal, from all signals, assuming a non-temperature dependent effect on top of the thermo-acoustic signal. The resulting amplitudes shown in Fig. 2 are well described by the model prediction. The source of the small non-thermo-acoustic signal which was only seen in the proton experiment could not be unambiguously verified with these experiments. The obvious difference to the laser experiment are the charges involved both from the protons themselves and the ionisation of the water. For clarification further experiments are needed either with ionising neutral particles(e.g. synchrotron radiation) or with charged particles(e.g. protons, α-particles) with more sensors positioned around the Bragg-peak. With such experiments it might be possible to distinguish between the effect of ionisation in the water and of net charge introduced by charged particles. 4. Conclusions We have demonstrated that the sound generation mechanism of intense pulsed beams is well described by the thermo-acoustic model. In almost all aspects investigated, the signal properties are consistent with the model. Relying on the model allows to calculate the characteristics of sound pulses generated in the interaction of high energy particles in water with the input of the energy deposition of the resulting cascade. A possible application of this technique would be the detection of neutrinos with energies 1EeV 7. References 1. G.A. Askariyan, Atomnaya Energiya 3, 152 (1957). 2. G.A. Askariyan et al., Nucl. Inst. Meth. 164, 267 (1979). 3. L. Sulak et al., Nucl. Inst. Meth. 161, 203 (1979). 4. S.D. Hunter et al., J. Acoust. Soc. Am. 69, 1557 (1981). 5. S.D. Hunter et al., J. Acoust. Soc. Am. 69, 1563 (1981). 6. V.I. Albul et al., Instr. Exp. Tech. 44, 327 (2001). 7. T. Karg et al., 1st International ARENA Workshop, Zeuthen (2005).