TeSys DF IEC-Type Fuseholders

Similar documents
MCB NB1-63H Miniature Circuit Breaker

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka

5SJ4...-.HG Circuit Breakers to IEC and UL 489

UL 1077 DIN Rail Supplementary Protectors

TeSys circuit-breakers

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka

5SP and 5SY Supplementary Protection UL 1077

X T O B P 1 6 B C 1 S

Universal limit switches

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Thermal-Magnetic Circuit Breaker 2210-T2...

TeSys contactors. TeSys D contactors. 690 V on a and c

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

General characteristics, Products

Semiconductor (AC) fuses

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

90 MCB range Modular circuit breakers for circuit protection

Semiconductor (AC) fuses

Specifications. Voltage Ratings: Interrupting Rating: Applications. Inverters Re-combiner boxes. LFJ 1000VDC Solar Series

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics

Non-Contact Safety Systems CMS

Thermal-Magnetic Circuit Breaker 2210-S2..

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

TeSys enclosed starters 2

Thermal-Magnetic Circuit Breaker 2210-S2..

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

Thermal-Magnetic Circuit Breaker 2210-S2..

Film Capacitors. EMI suppression capacitors. Date: June 2018

Semiconductor (AC) fuses

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

BETA Protecting Miniature Circuit Breakers

NH fuse-links gg 500VAC double indicator/live tags size 000, 00, 0, 1, 2, 3

Semiconductor (AC) fuses

Performance. Standards. Technical data

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

DATA RACK BUSBAR. Data Rack Busbar Systems A.

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Redline Unibis : the solution Circuit protection

Performance. Standards. Technical data

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

PHOENIX CONTACT - 04/2016. Features

Non-Fused. Series DS2 IEC Non-Fused 12 Disconnect Switches. Accessories 15. Specifications 16. Dimensions 17. See Enclosed Disconnects 21

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

MKV AC Capacitors Damping B High dielectric strength High peak-current capability Especially suitable for snubber circuits

Imformation of C091D series

Impedance relay and protection assemblies

Switches in conformity with ATEX directive

32 Input AC Block I/O Module

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

TECHNICAL INFORMATION

Zelio Relay - Solid State Relays

File E28476 Vol. 7 Sec. 44 Page 1 Issued: Vol. 23 Sec. 18 Revised: Vol. 67 Sec. 4 and Report D E S C R I P T I O N

3VT4 Molded Case Circuit Breakers up to 1000 A

2.3. Rockers. Contents

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

General Purpose Relays Types K, R, N, and C

Semiconductor (AC) fuses

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM

8 Installation Equipment

E8EB-N0C2B E8EB-N0B2B

16 Input AC Block I/O Module

Analogue Meters CQ2x07 series

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

Qualification Test Report. Modular Plugs, Unshielded and Shielded

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

SPF SERIES SOLAR FUSES

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

EMI Suppression PCRC 420 film capacitors (RC unit)

Model M3484 Industrial Line Noise Filter Module Customer Reference Manual

S R O T C U D IN & MYRRA

BMXART0814 analog input module M340-8 inputs - temperature

473 Dew Point Hygrometer

7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT.LTD.

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A

ATyS Automatic and remotely operated transfer switches from 125 to 3200 A

General characteristics

2-2. Bulletin 140M Motor Protection Circuit Breakers. Product Overview. Table of Contents. Standards Compliance. Certifications. General Information

KLKd Series 10x38 FUSES

Interference suppression film capacitors MKP 336 1

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

Dimension OD±1. General Technical Data. Technical Characteristics GB IEC252:1992 Operating temperature -25 ~+70. Capacitance Tolerance

BMXART0814 analog input module M340-8 inputs - temperature

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

SIRCOVER Manual transfer switches from 125 to 3200 A

440V 500V V / / /2 12.

473 Dew Point Hygrometer

Miniature Circuit Breaker

Single Core XLPE/LSF/AWA/LSF Power Cable

ct m ive p 5/EC Thermal cut-outs

Transcription:

TeSys DF IEC-Type 9080CT080 08 Contents... Page Characteristics......3 Accessories... Dimensions...5 Wirg diagrams...5 Fuses...6 7

Characteristics TeSys DF IEC-Type Fuseholder type DF8 DF0 DF DF DFCC Environment characteristics Conformg to standards IEC 6097-3, UL 5, CSA - n 39 Protective treatment Degree of protection Conformg to IEC 6059 IP 0 TH, treatment for hot and humid environments Ambient air temperature Storage C ( F) - 0 + 80 (- 0...+ 76) For operation, with deratg () C ( F) - 0 + 60 (-...+ 0) Flame resistance Conformg to IEC 60695-- C ( F) 960 (760) Pole characteristics Fuse size mm (ch) 8.5 x 3.5 0 x 38 (0. x.5) x 5 (0.6 x 5) x 58 Utilization category AC0B Rated sulation voltage (Ui) V 500 690 690 690 600 with tubular lks, a.c. supply Rated operational Hz 50/60 Rated impulse withstand voltage (Uimp) kv 6 6 8 8 6 Conventional thermal current (Ith) for ambient air temperature y 0 C () With tubular lks A 5 3 50 5 30 0 x 38 (0. x.5) CC fuse With am cartridge fuses A 5 3 50 5 30 With gg cartridge fuses A 5 3 50 00 30 Short-circuit characteristics (with tubular lks) Permissible short-time A 300 385 800 00 300 ratg (low) (rms value Cos ϕ = 0.35) Conformg to IEC 6097-3 Maximum permissible peak value (dynamic stress) Conformg to IEC 6069- ka 5 5 9 Certifications File E3069 CCN IZLT File E3069 CCN IZLT8 E3069 CCN IZLT Wire sizes (number of conductors x c.s.a.) M. Max. M. Max. M. Max. M. Max. M. Max. Solid wire mm (AWG) x.5 ( x ) x 5 ( x ) x 0 ( x 8) x.5 ( x ) x 35 ( x ) x 5 ( x ) x 6 () Tighteng torque Flexible wire without cable end mm (AWG) Flexible wire with cable end mm (AWG) Nm (lb-) x.5 ( x ) x.5 ( x ) x 5 ( x ) x 0 ( x 8) x 5 ( x ) x 0 ( x 8) x.5 x 35 ( x ) ( x ) x 5 ( x ) x.5 x 35 ( x ) ( x ) x 5 ( x ). (9) 3.5 (3) (35). (9) Characteristics of early break and signallg contacts DFAM and DFAM Rated sulation voltage (Ui) V 50 a.c. supply Conventional thermal current (Ith) for ambient air temperature y 0 C () A 5 Rated operational current V 8 V 7 V 0 V Category AC-5 A 3.5 Category DC-3 A 3 0. 0. Defition of rated characteristics Low load operatg characteristics Cablg Conformg to B300 IEC 6097-5- Mimum voltage V 0 Mimum current ma 30 Faston connectors () For use an stallation with ambient temp. > 0 C (68 F), apply a deratg coeffi cient: Max temperature C ( F) 0 (68) 30 (86) 0 (0) 50 () 60 (0) Max. relative humidity 95 % 90 % 80 % 50 % 50 % Current deratg coefficient 0.95 0.9 0.8 0.7 x 6 () x 6 ()

TeSys DF IEC-Type 06786 06788 () Conventional thermal current (Ith) Size of cartridge fuse or lk Composition P = Poles(s) N = Neutral A mm (ch) 5 8.5 x 3.5 P DF8 0.06 (.5) N DF0N 0.07 (.50) P + N () 6 DF8N 0.3 (.66) P 6 DF8 0. (.30) 3 P DF83 0.83 (6.6) 3 P + N () 3 DF83N 0.5 (8.96) 06793 DF0 06795 DF03N 3 0 x 38 (0. x.5) P DF0 0.06 (.5) N DF0N 0.07 (.50) P + N () 6 DF0N 0.3 (.66) P 6 DF0 0. (.30) 3 P DF03 0.83 (6.6) 3 P + N () 3 DF03N 0.5 (8.96) 0683 0679 0683 DF DF DF0NV 0685 068 0679 DF3NC DF3NC DF03V 50 x 5 5 x 58 P 6 DF 0.0 (.9) N 6 DFN 0.50 (5.9) P + N () 3 DFN 0.90 (0.3) P 3 DF 0.80 (9.88) 3 P DF3C (3) 0.0 (.8) 3 P + N () DF3NC (3) 0.570 (0.) P 6 DF 0.8 (7.69) N 6 DFN 0.38 (8.0) P + N () 3 DFN 0.56 (6.09) P 3 DF 0.36 (5.38) 3 P DF3C (3) 0.65 (3.07) 3 P + N () DF3NC (3) 0.89 (3.6) with blown fuse dicators (neon) () () Conventional thermal current (Ith) Size of cartridge fuse or lk Composition P = Pole(s) N = Neutral A mm (ch) 5 8.5 x 3.5 3 0 x 38 (0. x.5) P DF8V 0.06 (.6) P + N () 6 DF8NV 0.35 (.76) P 6 DF8V 0.5 (.) 3 P DF83V 0.86 (6.56) 3 P + N () 3 DF83NV 0.57 (9.07) P DF0V 0.06 (.6) P + N () 6 DF0NV 0.35 (.76) P 6 DF0V 0.5 (.) 3 P DF03V 0.86 (6.56) 3 P + N () 3 DF03NV 0.57 (9.07) DFNV DF3VC 50 x 5 P 6 DFV 0.3 (5.0) P + N () 3 DFNV 0.93 (0.3) P 3 DFV 0.83 (9.98) 3 P DF3VC (3) 0.3 (.9) 3 P + N () DF3NVC (3) 0.573 (0.) 0683 06835 5 x 58 P 6 DFV 0. (7.80) P + N () 3 DFNV 0.59 (6.9) P 3 DFV 0.39 (5.9) 3 P DF3VC (3) 0.657 (3.8) 3 P + N () DF3NVC (3) 0.895 (3.57) DFNV DF3VC () Each pole can be marked. A clip- marker holder is provided for this purpose. Clip- markers type AB Rp or AB Gp can also be used. () N: neutral pole fitted with a locked tubular lk as standard. (3) A letter C the catalog number dicates that the fuseholder can be fi tted with auxiliary early break, blown fuse signallg and fuse present signallg contacts. () Operational voltage of the blown fuse dicator: 0 V...690 V. 3

TeSys DF IEC-Type 06786 06836 596 06786 DFCCV DFCC3V DF AMp Detail of assembly clip and p mountg () Conventional thermal current (Ith) Size of cartridge fuse or lk Composition P = Poles A 30 Class CC P DFCC 0.06 (.5) P 6 DFCC 0. (.30) 3 P DFCC3 0.83 (6.6) with blown fuse dicators (neon) () Conventional thermal current (Ith) Size of cartridge fuse or lk P = Poles A 30 Class CC P DFCCV 0.06 (.6) P 6 DFCCV 0.5 (.) 3 P DFCC3V 0.86 (6.56) Accessories Auxiliary early break and blown fuse signallg contacts () Size of cartridge fuse or lk mm (ch) DF x 5 (0.6 x 0) DF X 58 Fuseholder assembly kits (3) to be assembled Size of cartridge fuse or lk mm (ch) DF8 8.5 x 3.5 DF0 0 x 38 (0. x.5) DF x 5 DF x 58 Number of contacts DFAM 0.05 (0.88) DFAM 0.09 (.0) DFAM 0.03 (.3) DFAM 0.035 (.3) Composition ps, clips 0 ps, 30 clips 0 ps, 30 clips Markg accessories Description Composition Markg Clip- markers Strip of 0 identical or letters DF0AP 0.007 (0.5) 0 DFAP 0.05 (0.88) 0 DFAP 0.08 (0.99) 0 9 5 ABRp () 0.00 (0.07) A Z 5 ABGp () 0.00 (0.07) () Each pole can be marked. A clip- marker holder is provided for this purpose. Clip- markers type AB Rp or AB Gp can also be used. () These auxiliary contacts provide the followg functions: early break, blown fuse signallg (if the Fuseholder is fitted with striker fuses) and fuse present signallg. (3) p and clips are required to assemble two DF8 or DF0 fuseholders together. p and 3 clips are required to assemble two DF or DF fuseholders together. () When orderg, replace the p the catalog number with the number or letter required. Example: AB-R or AB-GA. Note: DF0 and DFCC fuseholders have been subjected to a current withstand of Ip = 9 ka and T = 38 kas at 800 V ac maximum, 00 ka. DF fuseholders have been subjected to a current withstand of Ip =. ka and T = 30 kas at 750 V ac maximum, 00 ka. DF fuseholders have been subjected to a current withstand of Ip = 0. ka and T = kas at 750 V ac maximum, 00 ka. DF0, DF, and DF devices accept fuses which provide supplementary protection and have not been evaluated by UL for use where branch circuit protection is needed.

Dimensions, Wirg diagrams TeSys DF IEC-Type Dimensions: mm (ch) Modular fuseholders 5 A and 3 A Mountg on 35 mm 5 rail DF8 and DF8V DF0 and DF0V DF0N DFCC and DFCCV 58 (.8) DF8N and DF8NV DF8 and DF8V DF0N and DF0NV DF0 and DF0V DFCC and DFCCV DF83 and DF83V DF03 and DF03V DFCC3 and DFCC3V DF83N and DF83NV DF03N and DF03NV 83 (3.7) 0.5 (.59) 5 (.77) 7 (.85) 6 (.5) 5.5 (0.) Modular fuseholders 50 A Mountg on 35 mm 5 rail 70 (.76) 7.5 35 5.5 70 (0.69) (.38) (.07) (.76) DF and DFV DFN DFN and DFNV DF and DFV DF3C and DF3VC DF3NC and DF3NVC 07 (.) 8.5 (.9) 5 (.77) 3.8 (0.5) 50.5 (.99) 6.5 (.03) 5.5 (.07) 78.75 (3.0) 05 (.3) 76.5 (3.0) Modular fuseholders 5 A Mountg on 35 mm 5 rail DF and DFV DFN DFN and DFNV DF and DFV DF3C and DF3VC DF3NC and DF3NVC 70 (.76) Wirg diagrams Modular fuseholders DFp P DFp N DFp P + N DFp P N 3 DFp 3P DFp 3P + N 6 6 3 5 N 3 5 5 6.5 (.0) (.98) 5 (.77) 50.5 (.99) 76.5 (3.0) (0.039) 35 (.38) 70 (.76) 05 (.3) 0 (5.5) 5

TeSys DF IEC-Type DF6 and GK Cartridge fuses Cartridge fuses without striker, Type am Cartridge fuse type Maximum rated voltage Ratg mm (ch) Vac A g (oz) Cyldrical 8.5 x 3.5 00 0 DFBA000 0 (0.35) 0 DFBA000 0 (0.35) 0 DFBA000 0 (0.35) 6 0 DFBA0600 0 (0.35) 8 0 DFBA0800 0 (0.35) 0 0 DFBA000 0 (0.35) DFCA DFEA DFFA Cyldrical 0 x 38 (0. x.5) Cyldrical x 5 C yldrical x 58 500 0.6 0 DFCA00 0 (0.35) 0.5 0 DFCA00 0 (0.35) 0.50 0 DFCA005 0 (0.35) 0 DFCA0 0 (0.35) 0 DFCA0 0 (0.35) 0 DFCA0 0 (0.35) 6 0 DFCA06 0 (0.35) 8 0 DFCA08 0 (0.35) 0 0 DFCA0 0 (0.35) 0 DFCA 0 (0.35) 6 0 DFCA6 0 (0.35) 00 0 0 DFCA0 0 (0.35) 5 0 DFCA5 0 (0.35) 500 0.5 0 DFEA00 0 (0.7) 0.50 0 DFEA005 0 (0.7) 0 DFEA0 0 (0.7) 0 DFEA0 0 (0.7) 0 DFEA0 0 (0.7) 6 0 DFEA06 0 (0.7) 8 0 DFEA08 0 (0.7) 0 0 DFEA0 0 (0.7) 0 DFEA 0 (0.7) 6 0 DFEA6 0 (0.7) 0 0 DFEA0 0 (0.7) 5 0 DFEA5 0 (0.7) 3 0 DFEA3 0 (0.7) 0 0 DFEA0 0 (0.7) 00 50 0 DFEA50 0 (0.7) 690 0 DFFA0 5 (.59) 6 0 DFFA06 5 (.59) 8 0 DFFA08 5 (.59) 0 0 DFFA0 5 (.59) 6 0 DFFA6 5 (.59) 0 0 DFFA0 5 (.59) 5 0 DFFA5 5 (.59) 3 0 DFFA3 5 (.59) 0 0 DFFA0 5 (.59) 50 0 DFFA50 5 (.59) 500 63 0 DFFA63 5 (.59) 80 0 DFFA80 5 (.59) 00 0 DFFA00 5 (.59) 00 5 0 DFFA5 5 (.59) 6

TeSys DF IEC-Type DF6 and GK Cartridge fuses DF3EA Cartridge fuses with striker, Type am Cartridge fuse type Maximum rated voltage Ratg mm (ch) Vac A g (oz) Cyldrical x 5 500 0 DF3EA0 0 (0.7) 0 DF3EA0 0 (0.7) 6 0 DF3EA06 0 (0.7) 8 0 DF3EA08 0 (0.7) 0 0 DF3EA0 0 (0.7) 0 DF3EA 0 (0.7) 6 0 DF3EA6 0 (0.7) 0 0 DF3EA0 0 (0.7) 5 0 DF3EA5 0 (0.7) 3 0 DF3EA3 0 (0.7) 0 0 DF3EA0 0 (0.7) 00 50 0 DF3EA50 0 (0.7) DF3FA C yldrical x 58 690 0 DF3FA0 5 (.59) 6 0 DF3FA06 5 (.59) 8 0 DF3FA08 5 (.59) 0 0 DF3FA0 5 (.59) 6 0 DF3FA6 5 (.59) 0 0 DF3FA0 5 (.59) 5 0 DF3FA5 5 (.59) 3 0 DF3FA3 5 (.59) 0 0 DF3FA0 5 (.59) 50 0 DF3FA50 5 (.59) 500 63 0 DF3FA63 5 (.59) 80 0 DF3FA80 5 (.59) 00 0 DF3FA00 5 (.59) 00 5 0 DF3FA5 5 (.59) 7

The efficiency of Schneider Electric brand solutions Used combation, Schneider Electric products provide quality solutions, meetg all your Automation & Control application requirements. Operator dialog Software tools Motion & Drives Systems & architectures Interfaces and I/O Automation Motor control Detection Mountg systems Power supplies A worldwide presence Constantly available b More than 5,000 pots of sale 30 countries. b A range of products that are right for you and comply with the standards the country where they are used. Technical assistance wherever you are b Our technicians are at your disposal to assist you fdg the optimum solution for your particular needs. b Schneider Electric provides you with all necessary technical assistance, throughout the world. www.schneider-electric.us Schneider Electric USA 800 Knightdale Blvd. Knightdale, NC 755 USA -888-SquareD (-888-778-733) www.schneider-electric.us Electrical equipment should be stalled, operated, serviced, and mataed only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arisg out of the use of this material. 008 Schneider Electric. All Rights Reserved. 9080CT080 November 008