Instrumental Chemical Analysis

Similar documents
Advanced Pharmaceutical Analysis

PAPER No. 12: ORGANIC SPECTROSCOPY MODULE No. 4: Basic principles and Instrumentation for IR spectroscopy

SPECTROSCOPY MEASURES THE INTERACTION BETWEEN LIGHT AND MATTER

Infrared Spectroscopy

Infrared Spectroscopy

Infrared Spectroscopy: Identification of Unknown Substances

Chemistry Instrumental Analysis Lecture 15. Chem 4631

Application of IR Raman Spectroscopy

Chapter 12 Mass Spectrometry and Infrared Spectroscopy

Infra Red Spectroscopy

Infrared Spectroscopy

1.1. IR is part of electromagnetic spectrum between visible and microwave

2001 Spectrometers. Instrument Machinery. Movies from this presentation can be access at

CHEM 3760 Orgo I, F14 (Lab #11) (TECH 710)

FTIR Spectrometer. Basic Theory of Infrared Spectrometer. FTIR Spectrometer. FTIR Accessories

Spectroscopy. Page 1 of 8 L.Pillay (2012)

Lecture 13 Organic Chemistry 1

Learning Guide for Chapter 3 - Infrared Spectroscopy

m m lighter 'atom' dominates 2 INFRARED SPECTROSCOPY All modes of vibrations are not IR active.

Structure Determination. How to determine what compound that you have? One way to determine compound is to get an elemental analysis

Radiant energy is proportional to its frequency (cycles/s = Hz) as a wave (Amplitude is its height) Different types are classified by frequency or

Determination of Chemical Composition and Molecular Microstructures: Infrared Spectroscopy

Fourier transform infrared spectroscopy (FTIR) is a method used to obtain an infrared

Fourier Transform IR Spectroscopy

Fourier Transform Infrared Spectroscopy of Metal Ligand Complexes *

Ultraviolet-Visible and Infrared Spectrophotometry

Química Orgânica I. Ciências Farmacêuticas Bioquímica Química. IR spectroscopy AFB QO I 2007/08 1 AFB QO I 2007/08 2

CHEM 51LB: EXPERIMENT 7 SPECTROSCOPIC METHODS: INFRARED SPECTROSCOPY (IDENTIFICATION OF FUNCTIONAL GROUPS)

12. Structure Determination: Mass Spectrometry and Infrared Spectroscopy

Infra-red Spectroscopy

Educational experiment package Volume 1. Molecular spectroscopy

Symmetric Stretch: allows molecule to move through space

Infrared spectroscopy. Siriphorn Laomanacharoen Bureau of Drug and Narcotic Department of Medical Sciences 2 March 2012

Spectroscopy. Fourier Transform Infrared (FT-IR) Spectroscopy

Molecular Spectroscopy. H 2 O e -

25 Instruments for Optical Spectrometry

CH 3. mirror plane. CH c d

Infrared Spectroscopy An Instrumental Method for Detecting Functional Groups

CHEM 3.2 (AS91388) 3 credits. Demonstrate understanding of spectroscopic data in chemistry

CHM 223 Organic Chemistry I Prof. Chad Landrie. Lecture 10: September 20, 2018 Ch. 12: Spectroscopy mass spectrometry infrared spectroscopy

Infrared spectroscopy

Ultraviolet-Visible and Infrared Spectrophotometry

Organic Spectra Infra Red Spectroscopy H. D. Roth. THEORY and INTERPRETATION of ORGANIC SPECTRA H. D. Roth. Infra Red Spectroscopy

Chapter 5. Infrared Spectrophotometry

CHEM 3760 Orgo I, S12, Exp 5 (Lab #6) (TECH 710: IR Unknown)

1901 Application of Spectrophotometry

Introduction to FT-IR Spectroscopy

Vibrational Spectroscopy

PAPER No. 12: ORGANIC SPECTROSCOPY MODULE No. 7: Instrumentation for IR spectroscopy

Lecture 11. IR Theory. Next Class: Lecture Problem 4 due Thin-Layer Chromatography

Table 8.2 Detailed Table of Characteristic Infrared Absorption Frequencies

IR absorption spectroscopy

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

William H. Brown & Christopher S. Foote

2. Infrared spectroscopy

Types of Molecular Vibrations

Infrared Spectroscopy

Ch 313 FINAL EXAM OUTLINE Spring 2010

Infrared Spectroscopy

Increasing energy. ( 10 4 cm -1 ) ( 10 2 cm -1 )

Questions on Instrumental Methods of Analysis

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

1 Which of the following cannot be used to detect alcohol in a breathalyser test? Fractional distillation. Fuel cell. Infrared spectroscopy

Lecture 0. NC State University

EXPT. 7 CHARACTERISATION OF FUNCTIONAL GROUPS USING IR SPECTROSCOPY

MASS and INFRA RED SPECTROSCOPY

Vibrations. Matti Hotokka

Fourier Transform Infrared Spectroscopy (Perkin Elmer - Spectrum One)

General Infrared Absorption Ranges of Various Functional Groups

Chem Homework Set Answers

Chapter 25: The Chemistry of Life: Organic and Biological Chemistry

Welcome to Organic Chemistry II

Organic Compound Identification Using Infrared Spectroscopy. Description

1. Which compound would you expect to have the lowest boiling point? A) NH 2 B) NH 2

Infrared Spectroscopy used to analyze the presence of functional groups (bond types) in organic molecules How IR spectroscopy works:

Chem HH W11 Notes - Dr. Masato Koreeda Date: January 5, 2011 Topic: _IR Spectroscopy_ page 1 of 3. fingerprint region

(2) Read each statement carefully and pick the one that is incorrect in its information.

Spectroscopic techniques: why, when, where,and how Dr. Roberto GIANGIACOMO

ORGANIC - BROWN 8E CH INFRARED SPECTROSCOPY.

E35 SPECTROSCOPIC TECHNIQUES IN ORGANIC CHEMISTRY

More information can be found in Chapter 12 in your textbook for CHEM 3750/ 3770 and on pages in your laboratory manual.

Chapter 1 Reactions of Organic Compounds. Reactions Involving Hydrocarbons

Instrumental Analysis: Spectrophotometric Methods

Unit 3 Organic Chemistry. 3.3 Structural Analysis Part 2:

Qualitative analysis of aramide polymers by FT-IR spectroscopy

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Introduction to Spectroscopic methods

Learning Guide for Chapter 3 - Infrared Spectroscopy

EXPT. 9 DETERMINATION OF THE STRUCTURE OF AN ORGANIC COMPOUND USING UV, IR, NMR AND MASS SPECTRA

Chemistry 343- Spring 2008

Spectroscopy tools for PAT applications in the Pharmaceutical Industry

6.2 Polyatomic Molecules

7a. Structure Elucidation: IR and 13 C-NMR Spectroscopies (text , , 12.10)

Calculate a rate given a species concentration change.

Chemistry Instrumental Analysis Lecture 3. Chem 4631

ORGANIC - BRUICE 8E CH MASS SPECT AND INFRARED SPECTROSCOPY

Chapter 4 Ultraviolet and visible spectroscopy Molecular Spectrophotometry

Vibrational Spectroscopies. C-874 University of Delaware

Glossary. Analyte - the molecule of interest when performing a quantitative analysis.

Transcription:

L11 page 1 Instrumental Chemical Analysis Infrared Spectroscopy Dr. Ahmad Najjar Philadelphia University Faculty of Pharmacy Department of Pharmaceutical Sciences 2 nd semester, 2016/2017

Infrared Spectroscopy L11 page 2 Energy of Infrared photon insufficient to cause electronic excitation. IR spectroscopy and also called Vibrational Spectroscopy is a tool for examining vibrations in molecules. IR spectra are usually taken in the range λ ~ 2.5 40.0µm, which corresponds to 4000 200 cm -1 wavenumber. The IR region of the electromagnetic spectrum ranges in wavelength from 2-15 µm. Conventionally the IR region is subdivided into three regions, near IR, mid IR and far IR. Most of the IR used originates from the mid IR region.

Infrared Spectroscopy Number of vibrational modes A molecule can vibrate in many ways, and each way is called a vibrational mode. Molecules with N atoms, have 3N 5 degrees of vibrational modes if linear, whereas nonlinear molecules have 3N 6 degrees of vibrational modes (also called vibrational degrees of freedom). As an example H 2 O, a non-linear molecule, will have 3 3 6 = 3 degrees of vibrational freedom. In order for a vibrational mode in a molecule to be "IR active," it must be associated with changes in the dipole moment. Simple diatomic molecules have only one bond and only one vibrational band. If the molecule is symmetrical, e.g. N 2, the band is not observed in the IR spectrum (called transparent bonds in IR). Asymmetrical diatomic molecules, e.g. CO, absorb in the IR spectrum. L11 page 3 The atoms in a CH 2 X 2 group, commonly found in organic compounds and where X can represent any other atom, can vibrate in nine different ways. Six of these involve only the CH 2 portion: symmetric and antisymmetric stretching, scissoring, rocking, wagging and twisting.

Infrared Spectroscopy The IR Spectroscopic Process There are two types of bond vibration: Stretch Vibration or oscillation along the line of the bond H C H symmetric Bend Vibration or oscillation not along the line of the bond L11 page 4 H C H asymmetric H H C H H C H H C H H C scissor in plane rock twist wag out of plane

Infrared Spectroscopy The IR Spectroscopic Process L11 page 5 As a covalent bond oscillates due to the oscillation of the dipole of the molecule a varying electromagnetic (EM) field is produced. The greater the dipole moment change through the vibration, the more intense the EM field that is generated When a wave of infrared light encounters this oscillating EM field generated by the oscillating dipole of the same frequency, the two waves couple, and IR light is absorbed Frequency of absorption of radiation can be predicted with a modified Hooke s Law. ν μ 1 2 c M M x x M M y y k μ Where: n = wavenumber of the abs. peak (cm -1 ) c = speed of light (3 x 10 10 cm/s) k = force constant m = reduced mass of the atoms M x = mass of atom x in kg M y = mass of atom y in kg

Infrared Spectroscopy The IR Spectroscopic Process L11 page 6 Example: Calculate the approximate wavenumber (cm -1 ) of the fundamental absorption due to the stretching vibration of a carbonyl group C=O. (The force constant for the typical double bond is about 1x10 3 N/cm) 3 12x10 kg/ mol 26 M C x1atom 2.0x10 23 6.02x10 atoms / mol kg 3 ( 16x10 ) 26 M O 2.7x10 kg 23 (6.02x10 ) M m M C M O M 26 C 2 26 O 26.0x10 kg x 2.7x10 26 (2.0 2.7) x10 kg kg 1.1x10 kg n 5.3x10 12 k m n 5.3x10 12 s / cm 3 1x10 N / cm 26 1.1x10 kg 1.6x10 3 cm 1 The carbonyl stretching band is found experimentally to be in the region of 1600 to 1800 cm -1 (6.3 to 5.6 mm)

IR Spectrum Infrared Spectroscopy Transmittance vs Wavenumber. Stretching frequencies have higher wavenumbers than those of bending. L12 page 7 Finger print region is complicated but unique for every compound A nonpolar bond in a symmetrical molecule will absorb weakly or not at all The high bond strength (short bond), the high IR wavenumber Lighter atoms show absorption at longer wavenumber Hybridization affect the force constant also. As (s) character increases, the bond becomes more strong and absorbs at higher wavenumber.

IR Spectrum Infrared Spectroscopy Conjugation effect by resonance, conjugation lowers the energy of a double or triple bond. The effect of this is readily observed in the IR spectrum: O O L12 page 8 1684 cm -1 1715 cm -1 C=O C=O Conjugation will lower the observed IR band for a carbonyl from 20-40 cm -1 provided conjugation gives a strong resonance contributor O C H 3 C X X = NH 2 CH 3 Cl NO 2 1677 1687 1692 1700 cm -1 O H 2 N C CH 3 vs. O O N O C CH 3 Strong resonance contributor Poor resonance contributor (cannot resonate with C=O) Inductive effects are usually small, unless coupled with a resonance contributor (note CH 3 and Cl above)

IR Spectrum Infrared Spectroscopy Steric effects usually not important in IR spectroscopy, unless they reduce the strength of a bond (usually π) by interfering with proper orbital overlap: O O L12 page 9 C=O: 1686 cm -1 CH 3 C=O: 1693 cm -1 Here the methyl group in the structure at the right causes the carbonyl group to be slightly out of plane, interfering with resonance Strain effects changes in bond angle forced by the constraints of a ring will cause a slight change in hybridization, and therefore, bond strength O O O O O 1815 cm -1 1775 cm -1 1750 cm -1 1715 cm -1 1705 cm -1 As bond angle decreases, carbon becomes more electronegative, as well as less sp 2 hybridized (bond angle < 120 )

IR Spectrum Infrared Spectroscopy L12 page 10 Hydrogen bonding Hydrogen bonding causes a broadening in the band due to the creation of a continuum of bond energies associated with it In the solution phase these effects are readily apparent; in the gas phase where these effects disappear or in presence of steric effects, the band appears as sharp as all other IR bands: Gas phase spectrum Steric hindrance to H-bonding H-bonding can interact with other functional groups to lower frequencies O H O C=O; 1701 cm -1

IR Spectrum Infrared Spectroscopy L12 page 11 Main stretching frequencies are distributed from 400 to 4000 cm -1 according to the reduced mass and bond strength. IR Peak properties Position (cm -1 ) in the spectrum Shape (broad or sharp) Intensity (weak, medium or strong). The intensity of an IR band is affected by two primary factors: Whether the vibration is one of stretching or bending. Stretching is more intense. Electronegativity difference of the atoms involved in the bond.

IR Spectrum Infrared Spectroscopy L12 page 12

IR Spectrum Infrared Spectroscopy L12 page 13

IR Spectrum Infrared Spectroscopy L12 page 14

IR Spectrum Infrared Spectroscopy L12 page 15

IR instrumentation Infrared Spectroscopy Two types of instruments for IR absorption measurements are commonly available: (1) Dispersive spectrophotometers with a grating monochromator. It function in a sequential mode. (2) Fourier transform spectrometers employing an interferometer. It is capable of simultaneous analysis of the full spectral range. The first category uses a monochromator with a motorised grating that can scan the range of frequencies studied. The second is based on the use of a Michelson interferometer or similar device coupled to a specialized computer that can calculate the spectrum from the interferogram obtained from the optical bench. However, the light sources and optical materials are identical for all instruments. L13 page 16

Infrared Spectroscopy IR instrumentation Dispersive spectrophotometers L13 page 17

IR instrumentation Dispersive spectrophotometers Infrared Spectroscopy L13 page 18 Dispersive Double beam IR Spectrophotometer The radiation coming from the light source is split in two by a set of mirrors. For small intervals in wavelength defined by the monochromator, light that has alternately travelled both paths (reference and sample) arrives at the detector. A mirror (chopper) rotating at a frequency of approximately 10 Hz orients the beam towards each of the optical paths. The comparison of both signals, obtained in a very short time period, can be directly converted into transmittance. Depending on the spectral range and on various constraints (rotation of the monochromator grating, response time of the detector) the spectrum can be recorded within minutes. The detector in this type of instrument is only exposed to a weak amount of energy in a given period of time because the monochromator only transmits a narrow band of wavelengths.

Infrared Spectroscopy IR instrumentation Dispersive spectrophotometers L13 page 19

Infrared Spectroscopy IR instrumentation Fourier transform spectrophotometers L13 page 20

IR instrumentation Fourier transform spectrophotometers Infrared Spectroscopy L13 page 21 In a FTIR spectrometer, the single beam instrument works on the same principles such as the dispersive instruments except that an interferometer of the Michelson type is placed between the source and the sample, replacing the monochromator. Irradiation from the source impacts on the beam splitter which is made of a germanium film on an alkali halide support (KBr). This device allows the generation of two beams, one of which falls on a fixed mirror and the other on a mobile mirror whose distance from the beam splitter varies. An interferometer uses a moving mirror to displace part of the radiation produced by a source, thus producing an interfere ram, which can be transformed using an equation called the 'Fourier transform' in order to extract the spectrum from a series of overlapping frequencies.

Interferometer Infrared Spectroscopy L13 page 22 Michelson interferometer: a certain configuration of mirrors, one of which is moved by a motor. As this mirror moves, each wavelength of light in the beam is exits the interferometer is the result of two beams interfering with each other. The resulting signal is called an interferogram which has the unique property that every data point (a function of the moving mirror position) which makes up the signal has information about every infrared frequency which comes from the source.

IR instrumentation Fourier transform spectrophotometers Infrared Spectroscopy L13 page 23 Fourier transform spectrometers have the advantages of speed, reliability, signal to noise (S/N). - In this technique, a full spectral scan can be acquired in about 1s, compared with the 2-3 min required for a dispersive instrument to acquire a spectrum. - Also, because the instrument is attached to a computer, several spectral scans can be taken and averaged in order to improve the signal to noise ratio for the spectrum. - In FTIR method there is no stray light, and replacement of the entrance slit by an iris yields a brighter signal so that the detector receives more energy - Wavelengths are calculated with a high precision which facilitates the comparison of spectra - The resolution is constant throughout the domain studied.

Infrared Spectroscopy IR instrumentation FT-IR components: (1) The Source L13 page 24 Nernst Glower Globar W filament lamp heated rare earth oxide rod (~1500 K) heated SiC rod (~1500 K) 1-10 μm 1-10 μm 1100 K 0.78-2.5 μm Hg arc lamp plasma >50 μm CO 2 laser stimulated emission lines 9-11 μm

Infrared Spectroscopy IR instrumentation FT-IR components: (2) The Interferometer L13 page 25 Interferometric system consists of a He-Ne laser, mirrors, beamsplilter. Laser signal is used to control the speed of the mirror-drive system at a constant level.

Infrared Spectroscopy IR instrumentation FT-IR components: (3) The Sample Sample types: Gas, liquid (Solution or neat liquids) or solid Solution or neat liquids - Can subtract out solvent by taking background/reference spectrum Solids can be deposited as thin film - Deposited as thin film on KBr disc by solvent evaporation CCl 4 is best, but now expensive/hard to find CHCl 3 & CH 2 Cl 2 next best, do not obscure much of spectrum - Pressed into KBr pellet The common method, but it is difficult to get right - Mixed with Nujol (petroleum oil, high boiling) obscure aliphatic region Samples typically applied to polished NaCl or KBr plate (IR inactive) Teflon tape can also be used if stretched thin Adventitious water can be a problem (false ID of ROH and RCO 2 H) L13 page 26

Infrared Spectroscopy IR instrumentation FT-IR components: (3) The Sample Gases Liquids L13 page 27 Solids

Infrared Spectroscopy IR instrumentation FT-IR components: (3) The Sample Attenuated Total Reflectance (ATR) For samples that are difficult to deal with, such as solids of limited solubility, films, threads, pastes, adhesives, and powders. The materials used as ATR crystals include ZnSe, AgCI, Ge, and Si materials. L13 page 28

Infrared Spectroscopy IR instrumentation FT-IR components: (3) The Sample Attenuated Total Reflectance (ATR) One of the major advantages of ATR spectroscopy is that absorption spectra are readily obtainable on a wide variety of sample types with a minimum of preparation. Threads, yarns, fabrics, and fibers can be studied by pressing the samples against the dense crystal. Pastes, powders, or suspensions can be handled in a similar way. Aqueous solutions can also be accommodated provided the crystal is not water soluble. The spectra obtained with ATR methods can differ from IR absorption spectra. L13 page 29 Spectrum of L-Arginine (Comparison of KBr pellet method and single-reflection ATR method)

Infrared Spectroscopy IR instrumentation FT-IR components: (4) The Detectors (Transducers) 1. Thermal transducer Constructed of a bimetal junction, which has a temperature dependant potential (V). (similar to a thermocouple) Have a slow response time, so they are not well suited to FT-IR. L13 page 30 2. Pyroelectric transducer Constructed of crystalline wafers of triglycine sulfate (TGS) that have a strong temperature dependent polarization. Have a fast response time and are well suited for FT-IR.

Infrared Spectroscopy IR instrumentation FT-IR components: (4) The Detectors (Transducers) 3. Photoconducting transducer Constructed of a semiconducting material (lead sulfide, mercury/cadmium telluride, or indium antimonide) deposited on a glass surface and sealed in an evacuated envelope to protect the semiconducting material from the environment. Absorption of radiation promotes nonconducting valence electrons to a conducting state, thus decreasing the resistance ( ) of the semiconductor. Fast response time, but require cooling by liquid N 2. L13 page 31

Application Infrared Spectroscopy L14 page 32 IR is most useful in providing information about the presence or absence of specific functional groups. IR can provide a molecular fingerprint that can be used when comparing samples. If two pure samples display the same IR spectrum it can be argued that they are the same compound. IR does not provide detailed information or proof of molecular formula or structure. It provides information on molecular fragments, specifically functional groups. Therefore it is very limited in scope, and must be used in conjunction with other techniques to provide a more complete picture of the molecular structure. Infrared spectroscopy is not as widely used for quantitative analysis as UV/Vis even though absorption should obey the Beer-Lambert law. Calibration problems arise because the band intensities are highly sensitive to small changes in slit width of the radiation source. Another problem with IR spectroscopy is that peaks are often not well resolved. Most cells used in IR spectrometry have KBr window and the path length is likely to vary with use due to corrosion.

Interpretation Infrared Spectroscopy L14 page 33

Interpretation Infrared Spectroscopy L14 page 34 C-H bond Bonds with more s character absorb at a higher frequency. C-C bond Increasing bond order leads to higher frequencies: C-C 1200 cm -1 (fingerprint region) C=C 1600-1680 cm -1 C C 2200 cm -1 (weak or absent if internal) Conjugation lowers the frequency: isolated C=C 1640-1680 cm -1 conjugated C=C 1620-1640 cm -1 aromatic C=C approx. 1600 cm -1

Interpretation Infrared Spectroscopy L14 page 35 O-H and N-H bonds Both O-H and N-H stretches appear around 3300 cm -1, but they look different. Alcohol O-H Broad with rounded tip when hydrogen bonding is present (sharp in the absence of hydrogen bonding). Carboxylic O-H Broad band from 2400-3500 cm -1 Secondary amine (R 2 NH) Broad (usually) with one sharp spike Primary amine (RNH 2 ) Broad (usually) with two sharp spikes. No signal for a tertiary amine (R 3 N)

Benzene ring Infrared Spectroscopy L14 page 36

Carbonyl bonds C=O Infrared Spectroscopy L14 page 37

L14 page 38 Guideline How to approach analysis of IR spectra Calculate Degrees of Unsaturation (DoU) (molecular formula) Note any band at 1715 cm -1 (carbonyl) Check for O-H and N-H Check for triple bonds Check for C=C and benzene ring Check for C-O and nitro group below 1550 cm -1 Lock at C-H region (C=C-H, C-C-H)

L14 page 39 39

L14 page 40 40

L14 page 41 41

Example L14 page 42 42

Example L14 page 43 43

Example L14 page 44 44

Q. L14 page 45 45

Q. L14 page 46 46

L14 page 47 47

Interpretation Infrared Spectroscopy L14 page 48

Tables

52

Exercises

TASK 1 2,2-dimethylamine 2-methylbut-1-ene 3-methylbutan-1-ol 4-hydroxybutanone 3-methylbutanoic acid butyl methanoate ethanenitrile propanal

TASK 1 2,2-dimethylamine 2-methylbut-1-ene 3-methylbutan-1-ol 4-hydroxybutanone 3-methylbutanoic acid butyl methanoate ethanenitrile propanal

TASK 2 butanoic acid butanone but-3-en-1-ol 2-methylpropan-2-ol 2-ethylbutan-1-ol pent-1-ene

TASK 3 1) Propene reacts with HBr to form H. H reacts with sodium hydroxide to form I, and I reacts with warm acidified potassium dichromate (VI) to form J. The infra-red spectra of H, I and J are given below, but it does indicate which is which. Identify the three compounds H, I and J, using the infra-red spectra below, and decide which spectrum belongs to which compound.

TASK 3 2) Compound E, which is a branched chain haloalkane, was found to have the composition by mass of 39.8% C, 7.3% H, and 52.9% Br. There were two peaks for the molecular ions in the spectrum at 150 and 152, of approximately equal intensity. E reacts with sodium hydroxide to form F, whose infra-red spectrum is shown. F does not undergo dehydration with concentrated sulphuric acid. F reacts further with acidified potassium dichromate (VI) to form G, whose infra red spectrum is also shown. Draw the structures and name E, F and G. Identify the species responsible for the peaks at 150 and 152 in the mass spectrum of E.