NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06

Similar documents
NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen

Report No: NCTL NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 12/14/15

Report No: NCTL S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 07/14/15. Test Specimen

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NORTH EAST WINDOWS USA, INC.

AIR-INS inc. 1320, boul. Lionel-Boulet, Varennes (Quebec) J3X 1P7 Tél. : (450) Fax : (450)

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NU VISTA WD, INC. SERIES/MODEL: Malibu 250 T TYPE: Fixed

THERMAL PERFORMANCE TEST REPORT

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT

SIMULATION TEST REPORT NCTL E0A0

Simulation Report (Revised) Rendered To: Showcase Custom Vinyl Windows 1002 Olde Towne Drive Irving, TX 75061

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 7400 TYPE: Fixed

NFRC SOLAR HEAT GAIN COEFFICIENT TEST REPORT. Rendered to: CLEAR FOCUS IMAGING

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION. SERIES/MODEL: 4000 TYPE: Fixed

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: INTERNATIONAL ARCHITECTURAL PRODUCTS, INC. DBA: UNITED STATES ALUMINUM

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

ASTM C THERMAL PERFORMANCE TEST REPORT. Rendered to: UNIVERSAL PULTRUSIONS, LLC. PRODUCT: Fiberglass Door Slab

Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods 1

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: TUBELITE, INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CMI ARCHITECTURAL PRODUCTS, INC.

WINDOW SIMULATION REPORT

THE EFFECTS OF CALORIMETER TILT ON THE INWARD-FLOWING FRACTION OF ABSORBED SOLAR RADIATION IN A VENETIAN BLIND

TEST METHOD FOR THERMAL TRANSMITTANCE AND AIR INFILTRATION OF GARAGE DOORS

Determination of thermal transmittance of window (test title)

Customer: Ashton Industrial Sales Ltd. South Road, Harlow Essex CM20 2AR UNITED KINGDOM. Project/Customer: Profilex HM spacer

CAE 463/524 Building Enclosure Design Fall 2012

Window air permeability measurement, watertightness and resistance to wind load (designation of the test)

TEST OF MEASURED SOLAR HEAT GAIN VARIATION WITH RESPECT TO TEST SPECIMEN TILT

National Fenestration Rating Council. Incorporated. NFRC [E0A1] Procedure for Determining Fenestration Product Condensation Resistance Values

Winter Night. Thermos 6mm Outdoors # #

Kirncroft Security Doors

Solar Radiation 230 BTU s per Hr/SF. Performance Glazing Coatings, Layers & Gases

CRYOGENIC CONDUCTION COOLING TEST OF REMOVABLE PANEL MOCK-UP FOR ITER CRYOSTAT THERMAL SHIELD

CAE 331/513 Building Science Fall 2016

Hanson Overhead Garage Door Company proudly presents: Residential 400 Series

THERMAL TRANSMITTANCE OF MULTI-LAYER GLAZING WITH ULTRATHIN INTERNAL PARTITIONS. Agnieszka A. Lechowska 1, Jacek A. Schnotale 1

Determination of installed thermal resistance into a roof of TRISO-SUPER 12 BOOST R

Introduction...COMB-2 Design Considerations and Examples...COMB-3

17.01 Maxblock Sunshades by Tubelite Description

Vinyl Products Pella Windows and Doors

5. Thermal Design. Objective: Control heat flow to: Maintain comfortable indoor conditions

Building Envelope Requirements Overview Page 3-4

FG 623 Window Wall. Optional Features Integrates with standard Kawneer windows

THE IMPLICATION OF ENERGY EFFICIENT BUILDING ENVELOPE DETAILS FOR ICE AND SNOW FORMATION PATTERNS ON BUILDINGS

ISO INTERNATIONAL STANDARD

Capstone Design: Energy Efficient Windows Triple Pane Window Analysis

Solar Energy Cooking with the Sun

SL27C SL32C. ScreenLine. Technical Catalogue. english. double-glazed unit 27 mm 32 mm

INVESTIGATING GLAZING SYSTEM SIMULATED RESULTS WITH REAL MEASUREMENTS

Assessing The Thermal Performance of Building Enclosure Materials Using A Medium-Size Hot Box Chamber Summer Meeting Torkan Fazli

Calculating the heat transfer coefficient of frame profiles with internal cavities

NFRC Errata and Addendum Log

ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS

UNIT FOUR SOLAR COLLECTORS

Lecture 4 Insulated glass units

TEST METHOD FOR STILL- AND FORCED-AIR JUNCTION-TO- AMBIENT THERMAL RESISTANCE MEASUREMENTS OF INTEGRATED CIRCUIT PACKAGES

1040 SLIDING MALL FRONT

Solar Flat Plate Thermal Collector

ISO INTERNATIONAL STANDARD. Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: Simplified method

Determining of Thermal Conductivity Coefficient of Pressed Straw (Name of test)

Vincent Barraud SOPREMA BASICS OF THERMAL INSULATION

REPORT NUMBER: GZU-001 ORIGINAL ISSUE DATE:

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: PNEUTEK, INC.

JULY, 2016 E.C Architects - Please contact your Kawneer representative for further assistance.

Comparison of methods to determine load sharing of insulating glass units for environmental loads

DEVELOPMENT OF THE MEASURING SYSTEM FOR ANALYSING THE THERMAL PROPERTIES OF CLOTHING

QIRT th International Conference on Quantitative InfraRed Thermography

W e a t h e r S e a l s for Windows and Doors. E x c e l l e n c e i n S h a p e a n d F u n c t i o n

HOT /05/2014. Page 1 of 14 GENERAL HOUSE CHARACTERISTICS. Natural Resources CANADA Version sample house report

THE IMPORTANCE OF INDOOR AND OUTDOOR AIR-FILM COEFFICIENT MEASUREMENT TO SOLAR CALORIMETERY

Performance Weather performance certified to BS 6375 Part 1. Window Security Manufactured and certified to BS 7950

A quantitative infrared thermography method for the assessment of windows thermal transmittance

Effect of Installing a Curved Venetian Blind to the Glass Window on Heat Transmission

TRANSPARENT INNOVATIVE MATERIALS: ENERGETIC AND LIGHTING PERFORMANCES EVALUATION

GATES BIC & RAILING SOVEREIGN RANGE. BURBAGE IRON CRAFT LTD

THERMAL SIMULATION REPORT. TCL2013-Origin-01 Prepared For:

TEST CERTIFICATE PARTIAL REPRODUCTION OF THE PRESENT CERTIFICATE IS PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION BY EKANAL.

HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

Security Boss Manufacturing LLC MAXSEAL Pet Doors

1 / 17. TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies. Test Report

File SV16101 Project 05CA December 1, 2005 REPORT

THERMAL DYNAMIC BEHAVIOR OF SINGLE COMPONENT: EXPERIMENTAL ANALYSIS AND NUMERICAL MODELING

Design strategy for Low e windows with effective insulation

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

Performance Assessment of PV/T Air Collector by Using CFD

PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. PRODUCT: SUN TUNNEL Domes TYPES: Acrylic and Polycarbonate

Contribution from the Aspen Research Corporation, Pando Technologies

ANSI/SPRI ES-1 Test Reports UL Classified Products

Radiant Heating Panel Thermal Analysis. Prepared by Tim Fleury Harvard Thermal, Inc. October 7, 2003

PERFORMANCE TEST REPORT. Rendered to: WORLDWIDE DOOR COMPONENTS, INC. PRODUCTS: PVC and Composite Door Jamb Material

Global Climate Change

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

The energy performance of an airflow window

*Refer to IBC Section , applicable when fall protection is required. Glass stresses are designed for a safety factor of of 4.0 (IBC ).

BACK TO BASICS: PIPE INSULATION

Energy flows and modelling approaches

O Plus Dry Bushing 69 kv system, 350 kv BIL, 3000 A. Table of contents

ESRL Module 8. Heat Transfer - Heat Recovery Steam Generator Numerical Analysis

PERFORMANCE EVALUATION OF REFLECTIVE COATINGS ON ROOFTOP UNITS

Transcription:

ALL SEASONS DOOR & WINDOW, INC. Report No: NCTL-110-8058-5S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06 Test Specimen NFRC Code Manufacturer : All Seasons Door & Window, Inc. Series/Model : A 200 Window Type : Vertical Slider - Double Hung VSDH Frame Composition : Aluminum w/ thermal breaks AT Sash/Vent/Panel Composition : Aluminum w/ thermal breaks AT Thermal Break Mat'l : Poured Urethane Overall Size : 48" wide by 72" high Glazing Description 7/8" Overall w/low E and Argon No. of Glazing Layers (including films): 2 2 Primary Glazing : Double Glazed DG Spacer Type : Aluminum A1 Gap Fill 1: Argon ARG Gap Fill 2: Gap Fill 3: Glass/Film Thicknesses (ext to int): 0.126", 0.122" Air Gap 1: 0.624" Air Gap 2: Air Gap 3: Secondary Glazing: Low Emissivity Coatings: Emissivity 1: 0.204 on Surface #3 Emissivity 2: None Emissivity 3: None Procedure: Standardized Thermal Transmittance (U st ) was determined using the NFRC Test Procedure with a temperature of 70 ± 0.5 F on the room side of the specimen and 0 ± 0.5 F on the weather side of specimen. The net air leakage across the test specimen was 0.0 cfm. Test Results: Results of the test period 1901-2101 on 03/16/02 using the Equivalent CTS Procedure: Thermal transmittance at test conditions (U s ) : 0.53 BTU/hr/ft 2 / F Standardized thermal transmittance of test specimen (U st ) : 0.52 BTU/hr/ft 2 / F Reference should be made to Thermal Performance Test Report Number NCTL-110-8058-5 for complete specimen description and test data. NATIONAL CERTIFIED TESTING LABORATORIES MARC A. CRAMER Technician

All Seasons Door & Window, Inc. -2- NCTL-110-8058-5 THERMAL PERFORMANCE TEST REPORT Client: All Seasons Door & Window, Inc. 28 Edgeboro Road East Brunswick, NJ 08816 Report No: NCTL-110-8058-5 Test Date: 03/16/02 Report Date: 08/15/02 Expiration Date: 03/31/06 Test Specimen: All Seasons Door & Window, Inc.'s Series "A 200" Tilt Double Hung Aluminum Prime Window with Low E and Argon. Test Method: "NFRC Test Procedure for Measuring the Steady State Thermal Transmittance of Fenestration Systems (April 1997 edition)". TEST SPECIMEN DESCRIPTION General: The test specimen was a one-over-one tilt double hung aluminum prime window measuring 48" wide by 72" high overall. The top sash measured 44-3/8" wide by 36" high. The bottom sash measured 45-1/16" wide by 35-3/8" high. The frame and sash were thermally broken using poured urethane thermal barriers, debridged to various dimensions between 3/32" and 3/16". Both sash were removable via a double spiral balance with locking tilt shoe located in each jamb track. One (1) metal sweep lock was located at 11-1/2" from each end of the interior meeting rail. The full length keeper was extruded onto the exterior meeting rail. One (1) extruded aluminum spring-loaded snap-lock was located at midspan of the head. The full length keeper was extruded onto the top rail. One (1) metal lockable tilt latch was located at each end of the top rail and interior meeting rail. One (1) stamped metal pivot bar was fastened with one (1) screw at each end of the exterior meeting rail and bottom rail. A rigid vinyl sash stop was snap-fitted at the top of each interior jamb track and bottom of each exterior jamb track. The frame and sash were of double screw butt-type corner construction. Glazing: Both sash were channel glazed using sealed insulating glass with a flexible vinyl glazing bead. The overall insulating glass thickness was 7/8" (measured 0.872") consisting of two (2) lites of double strength (average thickness 0.124") annealed glass and one (1) argon-filled space created by a desiccant-filled aluminum spacer system. An AFG "Comfort E2" pyrolytic type low emissivity coating (e=0.204 per client) was applied to glazing surface no. 3. Weatherseals: A single strip of center fin weatherstrip (0.210" high) was located at the head, sill, top rail and exterior meeting rail. Double strips of center fin weatherstrip (0.210" high) were located at the interior meeting rail and all sash stiles. A single strip of dual leaf flexible vinyl weatherstrip was located at the bottom rail. Weeps: No apparent weeps employed. Interior & Exterior Surface Finish: Brown painted aluminum. Sealant: The frame and sash corners were sealed with a silicone sealant. Screen: No screen employed.

All Seasons Door & Window, Inc. -3- NCTL-110-8058-5 SPECIMEN PREPARATION PRIOR TO TEST The test specimen was pre-conditioned at ambient laboratory conditions prior to the test. The surround panel-to-specimen interfaces were sealed with a non-reflective tape. The specimen was sealed on the exterior with a caulk sealant resulting in a measured net air leakage of 0.0 cfm per square foot. TEST PARAMETERS Tests to determine the Standardized Thermal Transmittance (U st ) of the specimen were performed in the guarded hot box apparatus located at the York, PA facility. The most recent calibration of the hot box apparatus was in May, 2001. The thermal performance evaluations were completed in accordance with the NFRC Test Procedure using a dynamic wind perpendicular to the specimen on the weather side and simulated natural convection on the room side. A zero static pressure differential (0.00" ± 0.04" H 2 O) was maintained across the specimen during the test by pressurizing the metering box on the room side. Data was collected over two successive 2 hour periods after 4 hours of steady state conditions as defined in section 5.2.1.A of the NFRC Test Procedure were achieved. The test was considered completed when the data of the successive 2 hour periods also satisfied the criteria defined in section 5.2.1.A of the NFRC Test Procedure. Glass Thickness and Glazing Deflection Glazing Glazing Deflection Deflection Glass Thicknesses Before Test During Test Top Sash 0.12", 0.12" 0.02" 0.03" Bottom Sash 0.12", 0.12" 0.00" 0.03" Measured Areas Test Specimen Projected Area : Test Specimen Interior Exposed (Wetted) Surface Area : Test Specimen Exterior Exposed (Wetted) Surface Area : Metering Box Opening Area : Metering Box Baffle Area : Exposed Area of Mods to Surround Panel Opening: Surround Panel Interior Exposed Area : 24.00 ft² 26.04 ft² 26.91 ft² 54.39 ft² 46.44 ft² 0.21 ft² 30.18 ft² THERMAL TRANSMITTANCE & CONDUCTANCE The test chamber environmental systems were initiated at 1445 on 03/14/02. The test conditions were considered stable for two consecutive two hour test periods from 1701 to 1901 and 1901 to 2101 on 03/16/02. The thermal performance test results were derived from the 1901 to 2101 test period. Test Conditions

All Seasons Door & Window, Inc. -4- NCTL-110-8058-5 Heat Flows Average Room Side Air Temperature t I 70.0 F Average Weather Side Air Temperature, t II 0.3 F Average Guard Box Air Temperature 74.4 F Metering Box Average Relative Humidity 1 % Measured Weather Side Wind Velocity 14.3 mph Static Pressure Difference Across Specimen 0.0 " H 2 O Heat Input Rate to Metering Box 1048.9 BTU/hr Surround Panel Heat Flow 114.4 BTU/hr Heat Flow Through Mods to Surround Panel Opening (k = 0.82) 2.7 BTU/hr Sensible Heat from Pressure Balance Air Flow 2.9 BTU/hr Metering Box Heat Flow 13.8 BTU/hr Flanking Loss Heat Flow 27.3 BTU/hr Net Test Specimen Heat Flow 887.8 BTU/hr Surface Temperature Data Specimen Area-Weighted Room Side Surface Temperature, t 1 47.4 F Specimen Area-Weighted Weather Side Surface Temperature, t 2 4.9 F Area-Weighted Room Side Frame Surface Temperature 39.9 F Area-Weighted Weather Side Frame Surface Temperature 5.1 F Area-Weighted Room Side Edge-of-Glass Surface Temperature 42.7 F Area-Weighted Weather Side Edge-of-Glass Surface Temperature 7.8 F Area-Weighted Room Side Center-of-Glass Surface Temperature 53.0 F Area-Weighted Weather Side Center-of-Glass Surface Temperature 3.8 F

All Seasons Door & Window, Inc. -5- NCTL-110-8058-5 Test Results & Calculated Test Data Test Specimen Thermal Transmittance, U s 0.53 BTU/hr/ft²/ F Method A - Area Weighted Procedure Room Side Surface Conductance, h I 1.63 BTU/hr/ft²/ F Weather Side Surface Conductance, h II 7.97 BTU/hr/ft²/ F Test Specimen Thermal Conductance, C s 0.87 BTU/hr/ft²/ F Standardized Room Side Thermal Transmittance, h sti 1.39 BTU/hr/ft²/ F Standardized Weather Side Thermal Transmittance, h stii 5.10 BTU/hr/ft²/ F Test Specimen Standardized Thermal Transmittance, U st 0.49 BTU/hr/ft²/ F Method B - Equivalent CTS Method Emittance of Glass, e1 0.84 Warm Side Baffle Emittance, eb1 0.93 Equivalent Room Side Surface Temperature 44.8 F Equivalent Weather Side Surface Temperature 7.7 F Room Side Baffle Surface Temperature 68.8 F Measured Room Side Surface Conductance, h I 1.47 BTU/hr/ft²/ F Measured Weather Side Surface Conductance, h II 4.97 BTU/hr/ft²/ F Test Specimen Thermal Conductance, C s 1.00 BTU/hr/ft²/ F Convection Coefficient, K 0.329 Radiative Test Specimen Heat Flow, Q r1 441.4 BTU/hr Conductive Test Specimen Heat Flow, Q c1 446.4 BTU/hr Radiative Heat Flux of Test Specimen, q r1 18.39 BTU/hr/ft² Convective Heat Flux of Test Specimen, q r2 18.60 BTU/hr/ft² Standardized Room Side Thermal Transmittance, h sti 1.40 BTU/hr/ft²/ F Standardized Weather Side Thermal Transmittance, h stii 5.10 BTU/hr/ft²/ F Test Specimen Standardized Thermal Transmittance, U st 0.52 BTU/hr/ft²/ F

All Seasons Door & Window, Inc. -6- NCTL-110-8058-5 Based on the listed test results, the standardized thermal transmittance of the test specimen (U st ) was determined to be 0.52 BTU/hr/ft²/ F. The results from the equivalent CTS procedure were chosen because the test specimen thermal transmittance (U s ) was less than 0.6. Attachment 1 to this report lists the measured surface temperature data as well as the area information used to calculate the area-weighted surface temperatures. Attachment 2 to this report is an isometric drawing showing surface thermocouple measurement locations corresponding to the data on Attachment 1. This test method does not include procedures to determine the heat flow due to either air movement through the specimen or solar radiation effects. As a consequence, the thermal transmittance results obtained do not reflect performances which may be expected from field installations due to not accounting for solar radiation, air leakage effects, and the thermal bridge effects that may occur due to the specific design and construction of the fenestration system opening. Therefore, it should be recognized that the thermal transmittance results obtained from this test method are for ideal laboratory conditions and should only be used for fenestration product comparisons and as input to thermal performance analyses which also include solar, air leakage, and thermal bridge effects. Per the client, the test specimen described in this report was a production line unit submitted for initial certification and plant qualification. Detailed drawings were available for laboratory records and compared to the test specimen at the time of this report. A copy of this report along with representative sections of the test specimen will be retained by NCTL for a period of four (4) years. The results obtained apply only to the specimen tested. This report may not be reproduced, except in full, without the written approval of National Certified Testing Laboratories. Testing described in this report was conducted in full compliance with NFRC requirements. NATIONAL CERTIFIED TESTING LABORATORIES MARC A. CRAMER Technician PATRICK D. HEIN Engineering Manager Person-in-Responsible Charge MAC/amb

ATTACHMENT 1 SURFACE TEMPERATURE MEASUREMENTS AND AREA INFORMATION All Seasons Door & Window, Inc. NCTL-110-8058-5 1901-2101 03/16/02 Individual Average Assigned 3-D Areas Per Thermocouple Surface Temperatures ( F) Thermocouple Location (ft²) Location # Room Side Weather Side Room Side Weather Side 1 33.9 2.8 0.84 1.00 2 32.9 7.0 0.39 0.63 3 43.4 3.6 0.92 1.06 4 24.1 3.8 0.17 0.15 5 39.6 11.5 0.50 0.38 6 42.4 8.2 1.06 0.72 7 45.6 6.1 0.78 0.75 8 33.2 9.8 0.30 0.19 9 64.7 7.9 0.30 0.19 10 43.1 6.5 0.78 0.75 11 33.9 1.0 0.36 0.97 12 35.5 9.0 0.33 0.28 13 35.1 8.6 0.33 0.28 14 34.1 2.0 0.36 0.97 15 40.1 7.3 1.20 1.20 16 51.3 4.9 6.90 6.90 17 45.6 8.8 1.20 1.20 18 33.6 2.2 1.20 1.20 19 54.7 2.8 6.91 6.91 20 51.5 12.9 1.20 1.20 TOTAL AREA 26.04 26.91 Average Room Side Area-Weighted Surface Temperature ( F) 47.4 Average Weather Side Area-Weighted Surface Temperature ( F) 4.9